testo Instruments 05722002 testo Saveris 2 User Manual

testo Instruments (Shenzhen) Co., Ltd testo Saveris 2

User Manual

testoSaveris 2  User Manual testo Saveris 2Introductiontesto Saveris 2 system is upgrading product basing on testo Saveris system.   In original system, wireless probes transfer measurement data to Saveris base through local area network, testo professional software manages data and supply service on data record and monitor.  In Saveris 2 system, data transfer from Internet basing on Qualcomm new Wi-Fitechnology, probes can communicate with the cloud through wireless router. Customer can visit testo cloud anywhere and anytime.  Check real time measurement data inside his account.  And can also use APP to achieve same functions.Testo Saveris 2 system include testo cloud and five Wi-Fi probes.
 testo Saveris 2 Application ¾Medicine production, quality inspection and storage monitor¾Building surrounding measurement and monitor¾Development, laboratory, hospital surrounding measurement and monitor¾Food cold chain measurement and monitor¾Plant production, transfer and storage measurement and monitortestoSaveris 2 ProbesTesto Saveris has five Wi-Fi probes:    T1, T2, T3, H1 and H2.Saveris T1 has inside temperature sensor, can continuously measure and record surrounding temperature and transfer to cloud website.  Saveris T1 passed EN12830 approval can use in food industrial surrounding measurement and monitor. wwww
Saveris T2 can support two channel external temperature probe, can continuously measure and record surrounding temperature and transfer to cloud website.  Saveris T2 passed EN12830 approval, can use in food industrial surrounding measurement and monitor. Saveris T3 support two channel TC probes, can continuously measure and record surrounding temperature and transfer to cloud website.
Saveris H1 has inside temperature sensor and humidity sensor, can continuously measure and record surrounding temperature and transfer to cloud websiteSaveris H2support external testo humidity probe, can continuously measure and record surrounding temperature and transfer to cloud website.
testo Saveris 2 Probe technical Data˖type  Saveris  T1 Saveris T2 Saveris T3 Saveris H1 Saveris H2 measurementOne insideNTCTwo externalNTCTwo external TCOne inside humidityOne external humidityMeasurement range -30…+50°C -50…+150°CK type TC:-195…+1350°Chumidity“ 0…100%RHhumidity˖0…100%RHJ type TC:-100…+750°CNTC: -30…+50°CNTC: -30…+70°CT type TC:-200…+400°C accuracy±0,5 °C ±0,5 °C ± (0,5 + 0.5%mv) °C ±2% RH,  ±2% RH, ±0,5 °C ±0,5 °C
resolution 0.1°C 0.1°C0.1°C(-200~999.9), others 1°C0.1°C, 0.1%, 0.1Ctd °C0.1°C, 0.1%, 0.1Ctd °CT90 response time40 minutesUp to external probeUp to external probe 10minutesUp to external probetesto Saveris 2 Probes Specification˖type Saveris T1 Saveris  T2Saveris  T3Saveris  H1Saveris  H2Order number 0572 2001 0572 2002 0572 2003 0572 2004 0572 2005Operate temperate range-30 … +50 °C -30 … +50 °C -30 … +50 °C -30 … +50 °C -30 … +50 °CStorage temperature range-40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °CMeasurement cycle5s ~ 24hour (default setting 15 min)  5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) Communication cycle 5s ~ 24hour (default setting 15 5s ~ 24hour (default setting 15 5s ~ 24hour (default setting 15 5s ~ 24hour (default setting 15 5s ~ 24hour (default setting 15
min) min) min) min) min) Data memory10000 data per channel10000 data per channel10000 data per channel10000 data per channel10000 data per channelLCD display yes yes yes yes yesBattery life4pcs L91 battery 2 years4pcs L91 battery2 years4pcs L91 battery2 years4pcs L91 battery2 years4pcs L91 battery2 yearsNorm EN12830 EN12830 ------ ------ ------accessoryGP AA batteryWall holderlockUSB cableGP AA batteryWall holderlockUSB cableGP AA batteryWall holderlockUSB cableGP AA batteryWall holderlockUSB cableGP AA batteryWall holderlockUSB cableWebsite configurationactiveyes yes yes yes yestesto Saveris 2 Probes Instruction ManualProduct description:
deviceLEDQR code˄probe serial number, cloud website adderess˅keywall holderUSB communication cablelockFirst stepInserting batteries:¾To open the battery compartment, remove two screws on battery cover by screwdriver.¾Insert batteries (4x 1.5 V type AA). Observe the polarity!¾To close the battery compartment, tighten screws by screwdriver.Probe Configuration¾Visit website˖https://intl.saveris2.net/GoToProbe¾Enter log in page and input personal account and password
¾Click and enter to Wi-Fi connecting page, click “Connect Wifi-logger”ˈinput  wireless router SSID and password to connect into internetDŽIn connect successfullyˈicon will displayed on Saveris probe LCD.¾Click “Probe” o enter configuration page.    Set probe basic configuration, input probe number, name, location, measurement cycle, communication cycle, start time and etc.…
Alarm Setting¾Click “Alarm” and enter alarm setting page, click“Alarm configuration”ˈset up alarm upper and lower limit value one by oneDŽ
Probe ManagementAfter probe configuration, probe list can be found in Saveris system, and also on-time measurement data, Wifi signal status, battery power statusDŽ¾Click name of probe and enter probe detailed information page which show detailed measurement status of each channel.    Click “configuration”, can enter configuration page to modify configuration of probe.
Measurement Data transferAfter configuration finish, probe can start measurement and transfer data to cloud side.  During data transferringˈicon  will be displayed on LCD.Customer can also scan QR code on front housing of Saveris probe to visit cloud.Question and Answers:* battery power<5%˖repalce batteriesoooo * external probes not connected* real value out of measurement rangePower is so low that no RF exposure calculation is needed.
FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to thefollowing two conditions: (1) this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that maycause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference causedby unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates uses and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged totry to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to   the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any   interference received, including interference that may cause undesired operation.      Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et   (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible   d'en compromettre le fonctionnemen