 Instruction manual  entesto 104-IR BTCombined infrared and penetration thermometer with Bluetooth®preliminary
2preliminary1. General information 31. General informationPlease read this document through carefully and familiarize yourself with the operation of the product before putting it to use. Keep this document to hand so that you can refer to it when necessary.2. Safety informationAvoid electrical hazards:  Do not conduct measurements on or near live parts!Adhere to the product safety/warranty requirements:  Always operate the instrument properly and according to its intended purpose and within the parameters specified. Do not use force.  Do not store with solvents (e.g. acetone).   Only open the instrument if this is expressly described in the documentation for the purpose of maintenance or repair work. Ensure correct disposal:  Dispose of defective rechargeable batteries and spent batteries at the collection points provided.   Send the instrument directly to us at the end of its life cycle. We will ensure that it is disposed of in an environmentally friendly manner.3. Intended useThe testo 104-IR BT is a robust food thermometer. The product is designed for the following tasks/areas: ·  Food sector: production, food service, spot check measurement, incoming goods. ·  Measuring liquids, pastes and semi-solid materials The following product components are designed for continuous contact with foodstuffs in accordance with Regulation (EC) 1935/2004: The immersion/penetration probe from the tip up to 2 cm before the probe handle or the plastic housing. If provided, information about penetration depths in the instruction manual or the mark(s) on the immersion/penetration probe should be observed. The product should not be used in the following areas:·  Potentially explosive areas·  For diagnostic measurements in the medical sectordeenfresitptsvnl????
4. Technical data44. Technical data4.1 Bluetooth ModulThe Bluetooth® option may only be operated in countries in which it is type approved.Feature   ValuesBluetooth     Range >20 m (free field)luetooth type    LSD Science & Technology Co., Ltd       L Series BLE Module (08 Mai 2013) based on TI CC254X chipQualified Design ID  B016552Bluetooth radio class  Class 3Bluetooth company  10274CertificationBelgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE), Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania (RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain (ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB), Republic of Cyprus (CY). EFTA countriesNorway and Switzerland. Other countriesUSA, Canada, Turkey, Australia, New Zealand, South Korea, India, Russia, JapanInformation from the FCC (Federal Communications Commission) This device complies with part 15 of the FCC Rules. Commissioning is subject to the two following conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to cope with interference, even if this has undesirable effects on operation. Changes The FCC demands that the user be informed that any changes or modifications to the instrument that are not explicitly approved by Testo AG may void the user’s right to use this instrument.preliminary5. Product description 54.2 General Technical dataFeature   ValuesPenetration probeSensor type    NTCMeasuring range  -50 to +250 °C / -58 to +482 °FResolution   0.1 °C/°F/°RAccuracy (±1 digit)  ±1.0 °C / ±1.8 °F (-50,0 to-30,1°C / -58.0 to -22.1 °F)      ±0.5 °C / ±0.9 °F (-30,0 to +99,9°C / -22.0 to +211.9 °F)       ±1 % of the measuring range (+100.0 to +250.0 °C / +212.0 to +482.0 °F)Response time t99  10 s (measured in moving liquid)Measuring rate   0.5 sInfrared measurementLens    10:1 + opening diameter of the sensor (12 mm / 0.47”)Spectral range    8 to 14 μmLaser type    2-point laserOutput / wavelength  < 1 mW / 650nmClass / standard  2 / DIN EN 60825-1:2007Measuring range  -30 - +250 °C / -22 - +482 °FResolution   0.1 °C/°F/°RAccuracy (at 23°C, ±1 digit)  ±2.5 °C / ±4.5 °F (-30.0 to -20.1 °C / -22.0 to -4.2 °F)     ±2.0 °C / ±3.6 °F (-20.0 to -0.1 °C / -4.1 to 31.9 °F)       ±1.5 °C / ±2.7 °F or ±1.5 % of the measuring value (0.0 to +250.0 °C / +32.0 to +482.0 °F)Measuring rate   0.5 sGeneralOperating temperature  -20 to +50 °C / -4 to +122 °FTransportation/   -30...+70 °C / -22 to +158 °F (without batteries)storage temperaturePower supply    2 x AAA batteriesBattery life    10 h (typical at 25°C / 77°F)Housing    ABS/TPE/PC and die-cast zinc/stainless steelProtection class   IP65Dimensions     281 x 48 x 21 mm / 11.06 x 1.89 x 0.83“ (immersion/penetration probe folded out)  178 x 48 x 21 mm / 7.01 x 1.89 x 0.83” (immersion/penetration probe folded up)Weight    210g / 0.433lbs (incl. batteries)Standards   EN 13485EC Directive    2004/108/ECWarranty    2 years, warranty terms: see www.testo.com/warrantyInformation on standardsThis product complies with the EN 13485 standard for penetration measurement.Suitability: S, T (storage, transportation)Environment: E (transportable thermometer)Accuracy class: 0.5Measuring range: -50...+250 °CAccording to EN 13485, the measuring instrument should be checked and calibrated regularly under the terms of EN 13486 (recommended frequency: yearly).Contact us for more information.deenfresitptsvnl????
7. Operation65. Product description1 Infrared sensor2 2-point laser3 Display4 Control keys:· [ON]: switches the instrument on· [OFF]: switches the instrument off (hold button down)· [ ]: switches to IR measurement, carry out IR measurement (hold button down)· [ ]: switches to contact measurement· [HOLD/MIN/MAX]: holds measuring value, displays minimum/maximum value, sends data to mobile device (Bluetooth)5  Fold-out immersion/penetration probe, folding out the probe switches the instrument on6  Battery compartment (at the back) 6. CommissioningInserting batteries1  Use a slotted screwdriver to undo the screw on the battery compartment.2  Open the battery compartment.3  Insert batteries (2x type AAA). Observe the polarity!4  Close the battery compartment.5  Tighten the screw.preliminary8. Settings 77. Operation7.1 Switching on/offSwitching on via fold-out probe  Fold out the probe.-  All display segments light up briefly. Contact measurement is enabled (  lights up).Switching on/off via control keys  Switch the instrument on: press [ON].-  All display segments light up briefly. IR measurement is enabled (  lights up).   Switch off the instrument: press and hold down [OFF] until the display goes off.The instrument switches off automatically if no key is pressed: for 10 minutes when the probe is folded out, or for 1 minute when the probe is folded up. 7.2 Changing the measuring mode  Contact measurement —> IR measurement: press [ ].  IR measurement —> contact measurement: press [ ].7.3 MeasuringObserve the information on IR measurement/contact measurement (see chapter below).Bluetooth mode Cnl1 (Controlled Mode) is enabled: Display shows bLE, all buttons are locked, instrument can be controlled by external mobile device only.IR measurement -  Instrument is on, IR measurement is enabled, Bluetooth mode Cnl2 (Autonomous Mode) is enabled.1  Start measurement: press and hold down [ ].2  Lock in on measurement object using the laser points: laser points mark the edges of the measuring range. -  The current measuring value is displayed.3  End measurement: release the key.-  Hold lights up. The last measuring value and min./max. value are saved until the next measurement, or until the instrument is switched off.4  Send data to mobile device: press [HOLD / MIN / MAX].  Switch between min., max. and recorded value: press [HOLD / MIN / MAX].deenfresitptsvnl????
9. Service and maintenance8The min./max. values can be reset:· press [ ] or switch the instrument off.  Restart measurement: press and hold down [ ].  Setting the emission level:· When IR measurement is enabled, press and hold down[ ] and [ ] at the same time (  lights up).· Emission level is displayed. · Use [ ] or [ ] to change the value and wait for 3 s.Contact measurement-  Instrument is on, contact measurement is enabled (  lights up), Bluetooth mode Cnl2 (Autonomous Mode) is enabled.1  Position the contact thermometer in the measurement object and initiate the measurement: press [ ].2  End measurement: press [HOLD / MIN / MAX].-  Hold lights up. The last measuring value and min./max. value are saved until the next measurement, or until the instrument is switched off.AutoHold function: if this function is enabled, the measurement is ended automatically as soon as the measuring value is stable, AutoHold lights up.4  Send data to mobile device: press [HOLD / MIN / MAX].  Switch between min., max. and recorded value: press [HOLD / MIN / MAX].The min./max. values can be reset:· switch the instrument off, switch to IR measurement or, while the held measuring value is displayed (Hold lights up), press and hold down [HOLD / MIN / MAX] until Clr lights up.  Restart measurement: press [ ].8. Settings-  The instrument is switched off.If no button is pressed for 3 s in settings mode, the instrument switches to the next view.1  Press and hold down [ ] and [ ] until AutoHold or Hold flashes.2  Switch the AutoHold function on (AutoHold) or off (Hold): press [] or [ ].-  °C, °F or °R flashes.3  Set measurement unit to degrees Celsius (°C), degrees Fahrenheit (°F) or degrees Réaumur (°R): press [ ] or [ ].-  flashes.4  Switch the laser on (on) or off (oFF): press [ ] or [ ].preliminary11. Information on infrared (IR) measurement 95  Select Bluetooth mode Cnl1 (Controlled Mode) oder Cnl2 (Autonomous Mode): press [ ] or [ ].-  The instrument switches to IR measurement.9. Service and maintenance9.1 Changing the batteries1  Use a slotted screwdriver to undo the screw on the battery compartment.2  Open the battery compartment.3  Insert batteries (2x type AAA). Observe the polarity!4  Close the battery compartment.5  Tighten the screw.9.2 Cleaning the instrumentOnly use weak, commercially available neutral/ household cleaning agents (e.g. washing-up liquid) to clean the instrument. Do not use aggressive cleaning agents or solvent! The housing and probe can be disinfected using an alcohol-based spray. In doing so, always follow the manufacturer’s instructions.   Clean the housing and probe under running water and rub dry with a towel.  Clean the lens carefully with a cotton bud dipped in water or medical alcohol.10. Questions and answersQuestion    Possible causes  Possible solution lights up   Low battery     Change batteries.IR measurement:  Measuring values    Keep to permissible    - - - lights up.    outside measuring range    measuring range.Contact measurement:  Valores de medición    Keep to measuring - - - lights.    outside permissible range     range. Instrument cannot   Batteries dead.     Change batteries. be switched onInstrument    Instrument switches off    Switch the   switches itself off.  automatically after 10 min    instrument on again      in contact measurement mode       and after 1 min after switching       on in IR measurement mode.If we have not been able to answer your question, please contact your local dealer or Testo Customer Service. For contact details, please visit www.testo.com/service-contact.deenfresitptsvnl????
12. Information on contact measurement1011.  Information on infrared (IR) measurement11.1 Measuring methodIR measurement is a visual measurement  Keep lens clean.  Do not carry out measurement with a foggy lens.  Keep the measuring range (the range between the instrument and the measurement object) free of obstacles. There must be no particles of dust or dirt, no humidity (rain, steam) and no gases.IR measurement is a surface measurementIf there is dirt, dust, frost, etc. on the surface, only the outermost layer is measured, i.e. the dirt.  For vacuum-packed food, do not measure at air pockets.  Where the values are critical, always measure separately with a contact thermometer. Particularly in the food sector: measure core temperature with a penetration/immersion thermometer.Adjustment time   If the ambient temperature changes (change of location, e.g. measurement indoors/outdoors), the instrument must be allowed to equalise for 15 minutes for infrared measurement.11.2 EmissivityMaterials have different emission levels. This means they emit various amounts of electromagnetic radiation. The emission level of the instrument has a default setting of 0.95. This is ideal for the measurement of food, non-metals (paper, ceramic, gypsum, wood, paints and varnishes) and plastics.preliminary11deenfresitptsvnl????11.3 Measuring range, distanceDepending on the distance of the measuring instrument from the measurement object, a specific measuring range is recorded. Measuring lens (ratio of distance : measuring range)In italics = laser Not in italics = measuring range* Optimised measuring distance12.  Information on contact measurement  Observe the minimum penetration depth for immersion/penetration probes:10x probe diameter   Avoid using in aggressive acids or alkalis.
testo AGPostfach 11 40, 79849 LenzkirchTesto-Straße 1, 79853 LenzkirchTelefon: (0 76 53) 6 81 - 0Fax: (0 76 53) 6 81 - 1 00E-Mail: info@testo.deInternet: http://www.testo.com0977 1042 en 01awww.testo.compreliminary
FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this  device must accept any interference received, including interference that may cause undesired operation.  NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment.   This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Power is so low that no RF exposure calculation is needed.