ZTE MG880PLUS CDMA 1X WIRELESS DATA TERMINAL User Manual

ZTE Corporation CDMA 1X WIRELESS DATA TERMINAL Users Manual

Users Manual

    CDMA2000 1X  Wireless Data erminal User Manual                                                 This Help is used for Wireless Data Terminal of MG880+.
Welcome to Use Help Document of Data Terminal Through Help document, you could know about the following contents: Introduction Safety Warnings and Precautions Run the Application Connect/Disconnect  Connection Records Voice Call Call History Short message Contacts Settings Help ZAPAK URL Web Trouble-shooting  Copyright Statement Copyright © 2008 by ZTE Corporation  All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. ZTE Corporation reserves the right to make modifications on errors or update specifications in this Help without prior notice
1. Introduction Thank you for choosing CDMA2000 1X Wireless Data Terminal (hereinafter referred to as Data Terminal) of ZTE Corporation.    Through a standard USB interface, Data Terminal supports CDMA2000 1X network. In the area where there is signal, it allows you to go surfing on the Internet, send & receive short messages, and make & receive phone calls. The pictures in this help are only used to demonstrate your Data Terminal’s functions, so they are maybe different from what you see on your Data Terminal. Please refer to your Data Terminal if they are differences. 2. Safety Warnings and Precautions z Use the original accessories or those authenticated by the manufacturer. Using any unauthenticated accessories may affect the data terminal’s performance, violate the warranty provisions or relevant national regulations about telecom terminals, or even cause body injury. z Do not disassemble, modify, frequently pull/plug the antenna, stretch, rotate or bend the antenna with great force. z Before pulling out the data terminal, please use Windows safely removing the hardware and make sure to exit the application. Do not directly pull out the terminal to avoid the damage of data terminal or the influence on the normal operation of operating system. z Do not forcefully plug/pull the data terminal to avoid the damage of connector. z Do not use your data terminal near weak signal or high-precision electronic devices. Radio wave interference may cause misoperation of electronic devices or other problems. z Turn off your data terminal on airplane where it’s forbidden to use it. The data terminal may affect the normal operation of electronic devices, therefore please follow the relevant regulations when using your mobile phone on airplane. z Turn off your data terminal in hospital where it’s forbidden to use it. The data terminal may affect the normal operation of medical apparatus, therefore please follow the relevant regulations when using your mobile phone in hospital. z Please do not use the data terminal near flammable or explosive materials, otherwise it might cause failure or fire. z Keep your data terminal away from water. This may cause overheating or failure if water or any other kind of liquid enters your mobile phone. Please do not use your data terminal near high temperature, damp or dusty place. z Keep your data terminal away from children to avoid shock, plunge or impact. It may cause body injury when the data terminal is used as a toy.
3. Run the Application After the application is installed successfully, the application icon will appear on your desktop. Double-click this icon or select from Start  Programs   ZTEMT   ZTEMT UI Run the application to display the user interface.  The icons on the interface are used to access the function, which indicate as below:  Connect  ZAPAK   Voice Call  Voice Log   Short Message  Net Connect  Net Log   Phone book  Setting  Help                Status Bar:    1X indication   Call indication  Signal strength indication. The more bars there are, the stronger signals are.   Missed call indication  CDMA network unavailable   Unread message indication  Connection indication   Inbox full indication  Sleep indication   No R-UIM card inserted indication  Roaming indication   R-UIM card inserted indication 4. Connect/Disconnect Connect         Click  icon to set the relevant parameters. For details, please refer to 12 “Setting” for details.         Click  to enter the interface.
        Click  .  After connecting to Internet, the current network information will appear on the interface. Double-click any place in the display area to view the connection drawing.  Please connect the Data Terminal and PC with USB extension cable under weak signal to obtain the optimal performance. If necessary, adjust the Data Terminal’s position and the antenna’s direction. Disconnect         After connecting to Internet, click  . 5. Connection Records Click  icon to view connection records. Connection records save the previous relevant information including Start at, Duration and Transmit bytes, which will help you know the status easily. By switching among “List”, “Monthly” and “Statistic”, you could inquire the records every time, by month or by time.  Note: The relevant information contained in connection records are just for user’s reference rather than the charging basis. Delete Connection Records Click   button to delete the records you have selected on the interface. Clear Connection Records Click   button to delete all the records. 6. Voice Call (If this feature is not supported by your Data Terminal, please skip over this chapter.) Click  to enter voice call interface.
Make a call         Click the digits in the right side of the interface, or input the digits directly from keyboard. Press   button or press “Backspace” to delete the previous input digit; press  button or press “Esc” to clear all the inputs.          Click   button in the right side of the interface or press “Enter” to make a call.  Receive a call         When there is an incoming call, your computer will alert and the incoming caller ID will appear on the interface.         Click   button in the right side of the interface or press “Enter” to receive the call.         Press   button or press “Esc” to reject the call. Redial the latest outgoing call         Click   button in the right side of the interface.  Call Waiting During a call, you could select to answer the second incoming call, and then you could switch between the two incoming calls. Please firstly apply for this service from your local telecom operator.         During a call, if there is a new incoming call, a pop-up window will prompt you that you have the second incoming call.          If you select to answer, please click “Accept waiting call” button. The previous call won’t be ended, but temporarily paused.         You could switch between two incoming calls by clicking “Switch call”. Three-way Call This function allows for the call among three parties. Please firstly apply for this service from your local telecom operator. Note: You need set “Show 3 way call button during calling”. Please perform the setting according to “Setting”.          You could click “Dial second call” button during a call, input the third-party number in the pop-up window, and then press “OK” button to call the third party. In this case, the original call won’t be ended, but temporarily paused.         If the third party answers the call, click “Start conference” to enter the conference call.
         During three-way conference call, click “Hangup second call” button to end the conference call, and return to the original call.  7. Call History (If this feature is not supported by your Data Terminal, please skip over this chapter.) Click  icon to view the call history. The outgoing/incoming calls are saved in call history, including missed calls, incoming calls, outgoing calls, and talk duration. You could select the type you want to view. Missed/Received/Dialed Calls         Click   button to delete your selected record.         Click   button to delete all records in Missed/ Received/Dialed catalog.         Click   button to dial the number.         Click   button to send a short message to this number.         Click   button to save this number to the phone book. Data Log         Click   button to clear the talk duration. 8. Short Message (If this feature is not supported by your Data Terminal, please skip over this chapter.) Click  icon to enter Short message interface. Send a Message         Input the text and the recipient’s number..         Input the recipient’s number or click   button to select the recipient from phone book.
        Add more recipients if you like.         Select priority.         Click   button to send a message.          Click   button to save the text into Draftbox. The received messages will be saved in the Data Terminal In-box. You could copy the messages from the Data Terminal In-box to PC In-box by selecting Copy or Copy All; you could also copy the messages from PC In-box to the Data Terminal In-box by selecting Copy. Take Data Terminal In-box as an example: Reply         Click   to reply to the sender.  Forward         Click   to forward this message to other recipients. Dial Sender’s Number         Click   to dial the sender’s phone number.  Save Sender’s Number         Click   to save the sender’s number into phone book. Delete         Click   to delete your selected records. Clear         Click   to delete all the records in the inbox..  Copy         Click   to copy your selected record into PC. Copy All         Click   to copy all the records from the data terminal to PC. 9. Contacts (If this feature is not supported by your Data Terminal, please skip over this chapter.)
Click   to view the Contacts. You could select to save the contacts in the PC, Modem (Data Terminal) Emergent. Take “Save the call history in PC” for example in the following: Add         Click   then input the contents and select “OK” to add a new contact. Edit         Click   then edit the contents and select “OK” to edit the contact information. Search for contacts         Click   to search for the contacts by name or number. Delete         Click   to delete your selected contact.  Delete All         Click   to delete all the contacts.  Send messages from the Contacts         Click   to compose the text. You could send the message to multiple recipients. Dial from the Contacts         Click   to dial your selected phone number. Copy         Click   to copy your selected contacts to other storage location. Copy All         Click   to copy all contacts to other storage location. Import the call history.          Click   to import the Contacts (*.txt format) in PC to the terminal. Export the call history.         Click   to export the Contacts (*.txt format) in the terminal to PC.
10.  Settings Click  to enter the settings interface.  Network Connection Settings         Set up the relevant parameters on the “Network” interface.         After the settings, click “Apply” button to save the settings on the current interface.         Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default..  Note: The default network setup parameters are as below. Different regions may have different network setup parameters, so please consult your local telecom operator. Phone: #777 User: card Password: card If your Data Terminal does not support some following functions, please neglect relevant description.  Other Settings:         Click “Options” to switch the interface, and you could set URL, etc. If you want to use conference call, please select “Show 3 way call button during calling”;         After the setting, click “Apply” button to save the settings on the current interface.         Click “Change Password” button to set lock device. The password is required when you start the application. The setting has nothing to do with "Default" button.         Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default. Select ring tone         After clicking “Ring”, you could set different ring tones for Unconditional forwarding, No answer forwarding, Busy forwarding and Call waiting.         After the settings, click “Apply” button to save the settings on the current interface.
        Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default. Supplementary Services         After clicking “Service”, you could set “Busy Forwarding”, “No answer forwarding”, “Unconditional forwarding”, “Call waiting”, etc. Double-click the selected option to modify the service number and forwarding number.         After the settings, click “call” button to send the corresponding request to the network system.          After the settings, click “Apply” button to save the settings on the current interface.         Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default. Update Select Manual Upgrade or Auto Upgrade for the software. 11.  Help Click  button to view the help file.          Click “Help” button to view the relevant help file; click “Online service” to enter our company’s website.         You could view the software version information under “About”. 12.  ZAPAK URL Web Click  button to directly connect ZAPAK URL web, URL:www.zapak.com.
13.  Common Failures Table: Failures  Causes  Solutions Error occurs during the program installation.  The setup file may be damaged.  Please download the program on our website WWW.ZTEMT.COM and reinstall it. Directly run the software before the Data Terminal is plugged in.  Close the software, plug in the Data Terminal and run it again. Open port failed.  The port is occupied by other applications, such as “Hyper terminal”, or the software is already run. Close relevant software and run the software again. R-UIM card is not inserted.  Insert R-UIM card. R-UIM card is  not inserted properly. Sometimes the front side and back side are confused. Please refer to User Guide. Properly insert R-UIM card. No R-UIM card. R-UIM card is damaged. Validate by using a CDMA terminal.   Replace R-UIM card. Antenna is not connected to the Access Box.  Insert the antenna into the Data Terminal. Out of the network service area.  Make sure it is in the CDMA network service area. No signal indicated. The antenna or RF component is damaged.  Replace relevant damaged parts. Wrong setting of parameters. (Phone, User, Password.)  Correct the parameter settings. Consult your service provider for details. Not enough money.  Consult your service provider for details. Dialing failed Network congestion or failure.  Try again later. The Data Terminal is being connected. (It usually occurs when the Internet connection is immediately made after the call is dialed.) Reconnect. Internet connection failure. Poor network signal.  View signal strength indication and check if the antenna is properly inserted. The program has already been installed in current system.  Firstly remove the original program and insert the terminal again. The installation program can't auto set up. (If the Data Terminal supports auto setup function.) Autorun function in CD-ROM is disabled because of installation of anti-virus software in the system, or Windows Vista system itself disabled Autorun function in CD-ROM in default. Open "My Computer" to enter CD-ROM disk ordinal, and double-click Setup.exe to install manually. CD-ROM will automatically disappear once the program is installed successfully. This is normal. If you want to display CD-ROM disk ordinal, you could firstly remove the program and then insert the terminal again. No CD-ROM disk ordinal in "My Computer".  The program is not yet installed, and no other previous version was installed in the system. Please restart your computer. Please contact your local operator or product technical support center if CD-ROM disk ordinal doesn't appear after your computer is restarted. The driver might be unable to work and the application is unable to run normally if the terminal is pulled out and plugged in again when the application is being used under Win2000 (SP4) operating system .In this case, the device in device manager will be marked with yellow exclamation mark, and the system must be restarted to run normally. The operating system needs installing Update Roll 1 patch for Win2K SP4. Please download the patch from the following web site and install it. http://www.microsoft.com/downloads/details.aspx?familyid=B54730CF-8850-4531-B52B-BF28B324C662&displaylang=en
14.  RF Exposure Information: FCC RF Exposure requirements: The highest SAR value reported under this standard during product certification for use next to the body is 0.988 W/kg.  This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter.  This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help

Navigation menu