Yaesu Musen 20224X20 AMATEUR RADIO-SCANNNING RECEIVER User Manual P65

Yaesu Musen Co., Ltd. AMATEUR RADIO-SCANNNING RECEIVER P65

Contents

USERS MANUAL 1

UHF FM TRANSCEIVERVX-127OPERATING MANUALVERTEX STANDARD CO., LTD.4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, JapanVERTEX STANDARDUS Headquarters10900 Walker Street, Cypress, CA 90630, U.S.A.YAESU EUROPE B.V.P.O. Box 75525, 1118 ZN Schiphol, The NetherlandsYAESU UK LTD.Unit 12, Sun Valley Business Park, Winnall CloseWinchester, Hampshire, SO23 0LB, U.K.VERTEX STANDARD HK LTD.Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,Kwun Tong, Kowloon, Hong Kong
ContentsScanning .......................................................... 36VFO Scanning .............................................. 37Manual VFO Scan ................................... 37Programmed VFO Scan ........................... 37Memory Scanning ........................................ 38How to Skip (Omit) a Channelduring Memory Scan Operation .............. 38Preferential Memory Scan ....................... 39Memory Bank Scan ................................. 40Programmable (Band Limit) Memory Scan(PMS) ........................................................... 41“Priority Channel” Scanning(Dual Watch) ................................................ 42Automatic Lamp Illuminationon Scan Stop ................................................ 44Band Edge Beeper ........................................ 44Emergency Feature ........................................ 46Emergency Channel Operation .................... 46Emergency Automatic ID (EAI) Feature ..... 47Smart Search Operation ................................ 49Internet Connection Feature ......................... 50ARTS (Automatic Range Transponder System)....... 52DTMF Operation ........................................... 55DTMF Pager Operation ................................ 57Miscellaneous Settings ................................... 60Password ...................................................... 60Changing the Channel Steps ........................ 61Receive Battery Saver Setup ........................ 62TX Battery Saver .......................................... 62Disabling the TX/BUSY Indicator .............. 63Automatic Power-Off (APO) Feature .......... 63Transmitter Time-Out Timer (TOT) ............ 64Busy Channel Lock-Out (BCLO) ................ 64DCS Code Inversion .................................... 65Changing the TX Deviation Level ............... 66Reset Procedures ............................................ 67Cloning ............................................................ 68Set Mode .......................................................... 70Specifications .................................................. 83Installation of the FTD-7 DTMF Pager Unit...... 84General Description ......................................... 1Accessories & Options ..................................... 2Controls & Connections .................................. 3Top & Front Panel .......................................... 3LCD ................................................................ 4Side Panel ....................................................... 5Keypad Functions .......................................... 6Installation of Accessories ............................... 8Antenna Installation ....................................... 8Installation of FNB-83 Battery Pack ............. 8Battery Charging ............................................ 9Low Battery Indication .................................. 9Belt Clip Installation .................................... 10Installation of FBA-25A Battery Case ......... 10Interface of Packet TNCs .............................. 11Operation ........................................................ 12Switching Power On and Off ....................... 12Adjusting the Audio Volume Level ............. 12Squelch Adjustment ..................................... 13Frequency Navigation .................................. 13Transmission ................................................ 15Advanced Operation ...................................... 16Keyboard Locking ........................................ 16Keypad/LCD Illumination ........................... 17Disabling the Keypad Beeper ...................... 17RF Squelch ................................................... 18Checking the Battery Voltage ...................... 18Repeater Operation ........................................ 19Repeater Shifts ............................................. 19Automatic Repeater Shift (ARS) ................. 19Manual Repeater Shift Activation ............... 20VFO Split Mode ........................................... 21CTCSS/DCS/EPCS Operation ...................... 23CTCSS Operation ........................................ 23DCS Operation ............................................. 24Tone Search Scanning ................................. 25EPCS (Enhanced Paging & Code Squelch)....... 26CTCSS/DCS/EPCS Bell Operation ............. 27Split Tone Operation .................................... 28Tone Calling (1750 Hz) ............................... 28Memory Mode ................................................ 29Memory Storage ........................................... 29Storing IndependentTransmit Frequencies (“Odd Split”) ........ 29Memory Recall ............................................. 30HOME Channel Memory ............................. 30Labeling Memories ...................................... 31Memory Offset Tuning ................................ 32Deleting Memories ....................................... 32Memory Bank Operation ............................. 33Moving Memory Data to the VFO ............... 34Memory Only Mode ..................................... 34
VX-127 OPERATING MANUAL 1GENERAL DESCRIPTIONThe VX-127 is a compact, high-performance subnersible FM hand-held providing up tofive watts of RF power and wealth of convenient features for the 2-meter amateur band.New and exciting features of the VX-127 are are the Emergency Automatic ID (EAI)function, that will automatically cause your VX-127 to transmit your callsign and engageyour rig’s microphone, even if you are disabled and unable to press the PTT switch; En-hanced Paging and Code Squelch (EPCS), that allows you to page a particular station andonly receive calls from that station, if desired; and a security Password feature, that willallow you to turn on and operate your transceiver only after you enter your Password.Additional features include a convenient access key for Vertex Standard’s WIRES™ (Wide-coverage Internet Repeater Enhancement System), a transmit Time-Out Timer (TOT),Automatic Power-Off (APO), Automatic Repeater Shift (ARS), Vertex Standard’s exclu-sive ARTS™ (Auto-Range Transponder System) which “beeps” the user when you moveout of communications range with another ARTS™ equipped station, plus provision forreduction of the TX deviation in areas of high channel congestion. And an RF squelchcircuit allows the owner to set the squelch to open at a programmable setting of the S-Meter, thus reducing guesswork in setting the squelch threshold.We appreciate your purchase of the VX-127, and encourage you to read this manual thor-oughly, so as to learn about the many exciting features of your exciting new Vertex Stan-dard hand-held transceiver!: IPX-7 Specification for submersibility: 3 ft. for 30 minutes
VX-127 OPERATING MANUAL2SUPPLIED ACCESSORIESFNB-83 7.2 V, 1,400 mAhRechargeable Nickel-Metal Hydride Battery PackNC-88B/COvernight Battery Charger (10-Hour)YHA-69 AntennaQuick Draw Belt ClipOperating ManualWarranty CardAVAILABLE OPTIONSFNB-83 7.2 V, 1,400 mAhRechargeable Nickel-Metal Hydride Battery PackNC-88B/C/UOvernight Battery Charger (10-Hour)VAC-370 Desktop Rapid ChargerCD-26 Charger CradleFBA-25A Dry Cell Battery Case for 6 “AA” Alkaline Cells (not supplied)CN-3 BNC-to-SMA AdapterCT-91 Microphone AdapterE-DC-5B DC Cable with Cigarette-Lighter AdapterE-DC-6 DC Cable; plug and wire onlyMH-57A4B Speaker/MicrophoneCMP460A Waterproof Speaker/MicrophoneVC-27 Earpiece/MicrophoneVC-24 VOX HeadsetFTD-7 DTMF Paging Unit:“B” suffix is for use with 100-120 VAC, “C” suffix is for use with 230-240 VAC, and“U” suffix is for use with 230 VAC.Availability of accessories may vary. Some accessories are supplied as standard per localrequirements, while others may be unavailable in some regions. This product is designedto perform optimally when used with genuine Vertex Standard accessories. Vertex Stan-dard shall not be liable for any damage to this product and/or accidents such as fire,leakage or explosion of a battery pack, etc., caused by the malfunction of non- VertexStandard accessories. Consult your Vertex Standard dealer for details regarding theseand any newly-available options. Connection of any non-Vertex Standard-approved ac-cessory, should it cause damage, may void the Limited Warranty on this apparatus.ACCESSORIES & OPTIONS
VX-127 OPERATING MANUAL 3Antenna JackConnect the supplied rubber flex antenna (or an-other antenna presenting a 50-Ohm impedance)here. MIC/SP JackThis four-conductor miniature jack provides con-nection points for microphone audio, earphoneaudio, PTT, and ground.Do not allow the VX-127 to become submerged in water while the plasticcover over the MIC/SP jack is removed. VOL/PWR KnobTurn this control clockwise to turn the radio on and to increase the volume. Counter-clockwise rotation into the click-stop will turn the radio off. DIAL KnobThis (inner) 20-position detented rotary switch is used for setting the operating fre-quency, and also is used for menu selections and other adjustments. SpeakerThe internal speaker is located here.LCD (Liquid Crystal Display)The display shows the current op-erating conditions, as described onthe next page. KeypadThese 8 keys select many of mostimportant operating features on theVX-127. The functions of the keysare described in detail on the pagesto follow. TX/BUSY Indicator LampThis indicator glows green when thesquelch opens, and turns red dur-ing transmit. MICThe internal microphone is locatedhere.CONTROLS & CONNECTORS (TOP & FRONT PANELS) 
VX-127 OPERATING MANUAL4CONTROLS & CONNECTORS (LCD)Operating FrequencyMemory Channel NumberS- & PO MeterSecondary KeypadActiveSkip Memory Channel orPreferential Memory ChannelRepeater Shift DirectionCTCSS/DSC OperationInternet ConnectionFeature ActiveKey Lock ActiveBell Alarm ActiveBattery Saver ActiveDual Watch ActivePriority ChannelBattery IndicatorMemory Bank ActiveLow TX Power SelectedAutomatic Power-Off ActiveDTMF Autodial Active Emergency Automatic ID (EAI)Feature Active
VX-127 OPERATING MANUAL 5 PTT (Push To Talk) SwitchPress this switch to transmit, and release it (to receive) after your transmission is com-pleted. MONI SwitchPressing this switch disables the noise squelching action, allowing you to hear veryweak signals near the background noise level temporarily.Press the [F] key on the keypad first, then press this switch to enable to adjustment ofthe squelch threshold level. EXT DC JackThis coaxial DC jack allows connection to an external DC power source (6-16V DC).The center pin of this jack is the Positive (+) connection.Do not allow the VX-127 to become submerged in water while the rubbercap over the EXT DC jack is removed.CONTROLS & CONNECTORS (SIDE PANEL)
VX-127 OPERATING MANUAL6CONTROLS & CONNECTORS (KEYPAD FUNCTIONS)Primary Function(PRESS KEY)Secondary Function(PRESS [F] + KEY)Third Function(PRESS & HOLD KEY)Activates the Internet Connectionfeature.Sets the frequency control to theMemory Recall mode.Activates the “Memory “Tune” modewhile in the Memory Recall mode.Selects the Memory Scan “Skip”channel-selection mode.Engages the Set (Menu) Mode. Selects the desired transmit poweroutput level.Activates the Key Lockout feature.Activates the “Alternate” keyfunction.Disables the “Alternate” keyfunction.Activates the “Memory Write” mode(for memory channel storage).Primary Function(PRESS KEY)Secondary Function(PRESS [F] + KEY)Third Function(PRESS & HOLD KEY)Starts the programmable scannerupward (toward a higher frequencyor a higher channel number)Activates the EMERGENCY feature.Activates the Key Lockout feature.
VX-127 OPERATING MANUAL 7CONTROLS & CONNECTORS (KEYPAD FUNCTIONS)Increases the VFO frequency byone step or moves the memorychannel to the next-highest channel.Tunes the VFO frequencyupward in 1 MHz steps.Starts the scanner upward(toward a higher frequency ora higher channel number).Decreases the VFO frequency byone step or moves the memorychannel to the next-lowest channel.Tunes the VFO frequencydownward in 1 MHz steps.Starts the scanner downward(toward a lower frequency ora lower channel number).Reverses the transmit and receivefrequencies while working through arepeater.Switches to the “Home” (favoritefrequency) Channel.NoneSets frequency control to the VFO mode.Toggles the VFO between “VFO A” and“VFO B” while in the VFO mode.Activates the Priority (Dual Watch)function.Starts the programmed VFO scannerupward  while in the VFO mode.Selects the Memory Bank while in theMemory Recall mode.Primary Function(PRESS KEY)Secondary Function(PRESS [F] + KEY)Third Function(PRESS & HOLD KEY)Primary Function(PRESS KEY)Secondary Function(PRESS [F/W] + KEY)Third Function(PRESS & HOLD KEY):You can exchange the function between the primary (press key) function and secondary (press[F] key +) function, if desired. See page 79 for details.
VX-127 OPERATING MANUAL8ANTENNA INSTALLATIONThe supplied antenna provides good results over the entirefrequency range of the transceiver. However, for enhancedreception on certain non-Amateur frequencies, you may wishto connect an antenna designed specifically for that frequencyrange, as the supplied antenna is necessarily a compromiseoutside the Amateur band, and cannot be expected to providehigh performance at all frequencies.To install the supplied antenna, hold the bottom end of theantenna, then screw it onto the mating connector on the trans-ceiver until it is snug. Do not over-tighten by use of extremeforce.Notes:Never transmit without having an antenna connected.When installing the supplied antenna, never hold the upper part of the antenna whilescrewing it onto the mating connector on the transceiver.If using an external antenna for transmission, ensure that the SWR presented to thetransceiver is 1.5:1 or lower, to avoid excessive feedline loss.INSTALLATION OF FNB-83 BATTERY PACKThe FNB-83 is a high-performance Ni-MH battery providing high capacity in a compactpackage. Under normal use, the FNB-83 may be used for approximately 300 charge cycles,after which operating time may be expected to decrease. If you have an old battery packwhich is displaying capacity which has become diminished, you should replace the packwith a new one.Installation of the battery is easy and quick:Insert the battery pack into the battery compart-ment on the back of the radio while tilting theBelt Clip outward, then close the Battery PackLatch until it locks inplace with a “Click.”To remove the battery,turn the radio off andremove any protectivecases. Open the BatteryPack Latch on the bot-tom of the radio, then slide the battery downward and out from the radio while tiltingthe Belt Clip out of the way.INSTALLATION OF ACCESSORIES
VX-127 OPERATING MANUAL 9BATTERY CHARGINGIf the battery has never been used, or its charge is depleted, it may be charged by connect-ing the NC-88 Overnight Battery Charger, as shown in the illustration, to the EXT DCjack. If only 12 ~ 16 Volt DC power is available, the optional E-DC-5B DC Cable (with itscigarette lighter plug) or E-DC-6 DC Cable (plug and wire only) may also be used forcharging the battery.A fully-discharged pack will be charged completely in 10 hours. Disconnect the NC-88from the EXT DC jack and the AC line outlet.INSTALLATION OF ACCESSORIESImportant NoteThe NC-88 is not designed to power the transceiver for operation (reception or trans-mission).Do not leave the NC-88 connected to the transceiver for continuous periods in excessof 24 hours. Long term overcharging can degrade the Ni-MH battery pack and signifi-cantly shorten its useful life.Please be advised that the NC-88 may contribute noise to TV and radio reception inthe immediate vicinity, so we do not recommend its use adjacent to such devices.LOW BATTERY INDICATIONAs your battery discharges during use, the voltage will gradually become lower. Whenthe battery voltage is becoming too low for reliable operation,the “ ” icon will blink on the LCD display, indicating that thebattery pack must be recharged before further use.Avoid recharging Ni-MH batteries before the “ ”indicator isobserved, as this can degrade the charge capacity of your Ni-MH battery pack.NC-88 E-DC-6E-DC-5B
VX-127 OPERATING MANUAL10BELT CLIP INSTALLATIONConnect the hanger to the rear of the VX-127, with the notch pointing directly up,using the supplied screw (Figure 1). Use only the screw included with the clip tomount the clip to the back of the VX-127.Clip the Quick-Draw Belt Clip onto your belt (Figure 2).To install the VX-127 into the Quick-Draw Belt Clip, align the hanger with the Quick-Draw Belt Clip, and slide the VX-127 into its slot until a click is heard (Figure 3).To remove the VX-127 from the Quick-Draw Belt Clip, rotate the VX-127 180 de-grees, then slide the VX-127 out from the Quick-Draw Belt Clip (Figure 4).INSTALLATION OF ACCESSORIESINSTALLATION OF FBA-25A ALKALINE BATTERY CASE (OPTION)The optional FBA-25A Battery Case allows operation of the VX-127 using six “AA” sizeAlkaline batteries.When installing batteries, insert the (–) end first, then press in the (+) end so the batterysnaps into place. Always replace all six batteries at the same time, paying attention to thepolarity indicated inside the case.The FBA-25A must not be used with rechargeable cells. The FBA-25A does not containthe thermal and over-current protection circuits (provided in the “FNB” series of Ni-MHBattery Packs) required when utilizing Ni-Cd and Ni-MH cells.Note that the power output and battery life will be much shorter when using Alkaline AAcells. They should be considered an emergency backup power source only, for this reason.Figure 4Figure 3Figure 2Figure 1
VX-127 OPERATING MANUAL 11The VX-127 may be used for Packet operation, using the optional CT-91 MicrophoneAdapter (available from your Yaesu dealer) for easy interconnection to commonly-avail-able connectors wired to your TNC. You may also build your own cable, using a four-conductor miniature phone plug, per the diagram below.The audio level from the receiver to the TNC may be adjusted by using the VOL knob, aswith voice operation. The input level to the VX-127 from the TNC should be adjusted atthe TNC side; the optimum input voltage is approximately 5 mV at 2000 Ohms.Be sure to turn the transceiver and TNC off before connecting the cables, so as to preventvoltage spikes from possibly damaging your transceiver.When you are operating on Packet, switch the Receive Battery Saver OFF, as the “sleep”cycle may “collide” with the beginning of an incoming Packet transmission, causing yourTNC not to receive the full data burst. See page 62 for details regarding Battery Saversetup.INTERFACE OF PACKET TNCS
VX-127 OPERATING MANUAL12Hi! I’m R. F. Radio, and I’ll be helping you along as you learn the manyfeatures of the VX-127. I know you’re anxious to get on the air, but I encour-age you to read the “Operation” section of this manual as thoroughly aspossible, so you’ll get the most out of this fantastic new transceiver. Now. . .let’s getoperating!SWITCHING POWER ON AND OFFBe sure the Battery Pack is installed, and that the battery is fully charged. Connect theantenna to the top panel ANTENNA jack.Rotate the top panel’s VOL/PWR knob (inner knob)out of the click-stop to turn on the radio. The currentDC supply voltage will be indicated on the display for2 seconds. After this 2 second interval, the display willresume its normal indication of the operating frequency.To turn the radio off, turn the VOL/PWR knob fullycounter-clockwise into the click stop position.ADJUSTING THE AUDIO VOLUME LEVELRotate the VOL/PWR knob (inner knob) to adjust the re-ceiver level for a comfortable listing level, using the back-ground noise as a reference. Clockwise rotation increasesthe volume level.OPERATION
VX-127 OPERATING MANUAL 13OPERATIONSQUELCH ADJUSTMENTTo set the squelch, press the [F] key, followed by the MONI switch just below the PTTswitch on the left side of the transceiver.Now rotate the DIAL (outer knob) to find the lowestsetting (“LVL 1” through “LVL 15”) that will just si-lence the background noise. Do not use a higher settingthan necessary, or sensitivity to weak incoming signalswill be degraded.Press the PTT switch momentarily when you’ve madethe new setting; this will return you to normal operation (without having transmitted).1) A special “RF Squelch” feature is provided on this radio. This featureallows you to set the squelch so that only signals exceeding a certain S-meterlevel will open the squelch. See page 18 for details.2) If you’re operating in an area of high RF pollution, you may need to consider “ToneSquelch” operation using the built-in CTCSS Decoder. This feature will keep your ra-dio quiet until a call is received from a station sending a carrier which contains a matching(subaudible) CTCSS tone. Or, if your friends have radios equipped with DCS (DigitalCoded Squelch) like your VX-127 has, try using that mode for silent monitoring of busychannels.FREQUENCY NAVIGATIONThe VX-127 will initially be operating in the “VFO” mode, a channelized system whichallows free tuning throughout the currently-selected operating band.Three basic frequency navigation methods are available on the VX-127:1) Tuning DialRotation of the DIAL (outer knob) allows tuning in the pre-programmed steps establishedfor the current operating band. Clockwise rotation of the DIAL causes the VX-127 to betuned toward a higher frequency, while counter-clockwiserotation will lower the operating frequency.If you press the [F] key momentarily, then rotate the DIAL,frequency steps of 1 MHz will be selected. This feature isextremely useful for making rapid frequency excursions overthe wide tuning range of the VX-127.
VX-127 OPERATING MANUAL142) ScanningPress and hold in either the [(MHz)] or [(MHz)] keyfor one second to initiate upward or downward scanning,respectively (Manual VFO Scan).For scanning within a limited sub-band range, from the VFOmode, press and hold in the [MR(SKIP)] key for one sec-ond to begin scanning toward a higher frequency within thepreviously-defined sub-band (Programmed VFO Scan). De-tails regarding sub-band setup may be found on page 37.If you wish to reverse the direction of the scan (i.e. toward alower frequency, instead of a higher frequency), just rotatethe DIAL one click in the counter-clockwise direction whilethe VX-127 is scanning. The scanning direction will be re-versed. To revert to scanning toward a higher frequency oncemore, rotate the DIAL one click clockwise.The scanner will stop when it receives a signal strong enoughto break through the Squelch threshold. The VX-127 will then hold on that frequencyaccording to the setting of the “RESUME” mode (Set Mode Item 32: RESUME). Press thePTT switch momentarily to cancel the scanning. This only stops the scan; it does not causetransmission to occur. See page 36 for details regarding Scan Operation.OPERATIONFREQUENCY NAVIGATION(PROGRAMMED VFO SCAN)(MANUAL VFO SCAN)
VX-127 OPERATING MANUAL 15OPERATIONTRANSMISSIONOnce you have set up an appropriate frequency inside the 144 MHz Amateur band onwhich the VX-127 can transmit, you’re ready to go on the air! These are the most basicsteps; more advanced aspects of transmitter operation will be discussed later.To transmit, press the PTT switch, and speak into thefront panel microphone (located in the lower left-handcorner of the speaker grille) in a normal voice level.The TX/BUSY indicator will glow red during trans-mission.To return to the receive mode, release the PTT switch.During transmission, the relative power level will beindicated on the bar graph at the bottom of the LCD; full scaledeflection confirms “High Power” operation, while deflectionof two bars indicates “Low Power” operation. Five bars indicate“Medium Power” operation. Additionally, the “LOW” icon willappear at the bottom of the display while operating on the “LowPower” and “Medium Power” settings.1) If you’re just talking to friends in the immediate area,you’ll get much longer battery life by switching to LowPower operation, described in the next chapter. And don’tforget: always have an antenna connected when you transmit.2) Transmission is possible only on the 144 MHz amateur band.Changing the Transmitter Power LevelTo change the power level:Press the [LOW(LOCK)] key. The LCD shows the cur-rent power output level.Rotate the DIAL knob to select the desired power out-put level. Available selections are “HIGH” (5 W), “MID”(2 W), and “LOW” (0.5 W).When you have made your choice, press the PTT switchto save the new setting and return to normal operation.1) The VX-127 is smart! When you store memories, you can store the poweroutput settings separately in each memory, so you don’t waste battery powerwhen using very close-in repeaters!2) When you are operating on the “Low” or “Medium” power setting, you can press the[F] key, then press the PTT switch, to cause the VX-127 to transmit (temporarily) onHigh power. After one transmission, the power level will revert to the previously-selected(“Low” or “Medium” power) setting.“LOW” POWER“MID” POWER“HIGH” POWER
VX-127 OPERATING MANUAL16Now that you’re mastered the basics of VX-127 operation, let’s learn more about some ofthe really neat features.KEYBOARD LOCKINGIn order to prevent accidental frequency change or inadvertent transmission, various as-pects of the VX-127’s DIAL and keypad may be locked out. The possible lockout combi-nations are:LK KEY: Just the front panel keypad is locked outLKDIAL: Just the top panel DIAL is locked outLK K+D:Both the keypad and DIAL are locked out (factory default)LK PTT: The PTT switch is locked out (TX not possible)LK P+K: Both the PTT switch and keypad are locked outLK P+D:Both the PTT switch and DIAL are locked outLK ALL: All of the above are locked outTo lock out some or all of the keys:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 26: LOCK.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to choose between one of the lockingschemes as outlined above.5. When you have made your selection, press the PTT switch tosave the new setting and return to normal operation.To activate the locking feature, (1) press and hold in the [LOW(LOCK)] key for onesecond, or (2) press the [F] key, followed by the [LOW(LOCK)]key. The “ ” icon will appear on the LCD. To cancel locking, re-peat this process.ADVANCED OPERATION
VX-127 OPERATING MANUAL 17ADVANCED OPERATIONKEYPAD/LCD ILLUMINATIONYour VX-127 includes a reddish illumination lamp which aids in nighttime operation. Thereddish illumination yields clear viewing of the display in a dark environment, with mini-mal degradation of your night vision.Three options for activating the lamp are provided:KEY Mode: Illuminates the Keypad/LCD lamp for five seconds when you rotatethe DIAL knob or press the keypad or any switch (except PTT switch).This is the factory-programmed default setting.CONT Mode: Illuminates the Keypad/LCD lamp continuously.OFF Mode: Disables the Keypad/LCD lamp.Here is the procedure for setting up the Lamp operating mode:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 25: LAMP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select one of the three modes describedabove.5. When you have made your choice, press the PTT switch to savethe new setting and return to normal operation.DISABLING THE KEYPAD BEEPERA keypad beeper provides useful audible feedback whenever a keypad is pressed.If you want to turn the beep off:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 6: BEEP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to change the setting to “OFF.”5. Press the PTT switch to save the new setting and return to nor-mal operation.6. To turn the beep back on again, select “KEY” or “KEY+SC (fac-tory default)” in step 4 above.KEY: The beeper sounds when you press the keypad.KEY+SC: The beeper sounds when you press the keypad, or when the scanner stops.
VX-127 OPERATING MANUAL18ADVANCED OPERATIONRF SQUELCHA special RF Squelch feature is provided on this radio. This feature allows you to set thesquelch so that only signals exceeding a certain S-meter level will open the squelch.To set up the RF squelch circuit for operation, use the following procedure:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 34: RF SQL.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select the desired signal strength levelfor the squelch threshold (S-1, S-2, S-3, S-4, S-5, S-6, S-8,S-FULL, or OFF).5. Press the PTT switch to save the new setting and return to nor-mal operation.CHECKING THE BATTERY VOLTAGEThe VX-127’s microprocessor includes programming which will measure the current bat-tery voltage.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 12: DC VLT.3. Press the [F] key momentarily to display the current DC voltagebeing supplied.4. Press the [F] key, followed by the PTT switch to return to nor-mal operation.
VX-127 OPERATING MANUAL 19REPEATER OPERATIONRepeater stations, usually located on mountaintops or other high locations, provide a dra-matic extension of the communication range for low-powered hand-held or mobile trans-ceivers. The VX-127 includes a number of features which make repeater operation simpleand enjoyable.REPEATER SHIFTSThe VX-127 has been configured, at the factory, with the repeater shift set to 1.6 MHz, 7.6MHz, or 5 MHz (USA version).Depending on the part of the band in which youare operating, the repeater shift may be eitherdownward (–) or upward (+), and one of theseicons will appear at the top of the LCD whenrepeater shifts have been enabled.AUTOMATIC REPEATER SHIFT (ARS)The VX-127 provides a convenient Automatic Repeater Shift feature, which causes theappropriate repeater shift to be applied automatically whenever you tune into the desig-nated repeater sub-bands in your country. These sub-bands are shown below.If the ARS feature does not appear to be working, you may have accidentally disabled it.To re-enable ARS:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 4: ARS.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select “ARS. ON.”5. When you have made your selection, press the PTT switch tosave the new setting and return to normal operation.Euro Version 1Euro Version 2Version A440.0 445.0 450.0439.45438.20433.00 433.40ARS-Repeater Subbands
VX-127 OPERATING MANUAL20MANUAL REPEATER SHIFT ACTIVATIONIf the ARS feature has been disabled, or if you need to set a repeater shift direction otherthan that established by the ARS, you may set the direction of the repeater shift manually.To do this:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 35: RPT.MOD.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select the desired shift among “RPT.–,”“RPT.+,” and “RPT.OFF.”5. When you have made your selection, press the PTT switch tosave the new setting and return to normal operation.If you make a change in the shift direction, but still have Automatic RepeaterShift still engaged (see previous section), when you change frequency (byrotating the DIAL knob, for example) the ARS will over-ride your manualsetting of the shift direction. Turn ARS off if you do not wish this to happen.If you make a change in the repeater shift on a memory channel that you already stored, theradio will consider this a “temporary” change unless you store the memory once more, thistime with the desired repeater shift engaged.Changing the Default Repeater ShiftsIf you travel to a different region, you may need to change the default repeater shift so as toensure compatibility with local operating requirements.To do this, follow the procedure below:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 41: SHIFT.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select the new repeater shift magni-tude.5. When you have made your selection, press the PTT switch tosave the new setting and return to normal operation.If you just have one “odd” split that you need to program, don’t change the“default” repeated shifts using this Set Mode Item. Enter the transmit andreceive frequencies separately, as shown on page 29.REPEATER OPERATION
VX-127 OPERATING MANUAL 21REPEATER OPERATIONMANUAL REPEATER SHIFT ACTIVATIONChecking the Repeater Uplink (Input) FrequencyIt often is helpful to be able to check the uplink (input) frequency of a repeater, to see if thecalling station is within direct (“Simplex”) range.To do this, just press the [REV(HOME)] key. You’ll noticethat the display has shifted to the repeater uplink frequency.Press the [REV(HOME)] key again to cause operation torevert to normal monitoring of the repeater downlink (out-put) frequency. While you are listening on the input fre-quency to the repeater using the [REV(HOME)] key, therepeater offset icon will blink.The configuration of this key may be set either to “RV” (for checking the input fre-quency of a repeater), or “HM” (for instant switching to the “Home” channel for theband you are operating on). To change the configuration of this key, use Set Mode Item33: REV/HM. See page 79.VFO SPLIT MODEFor working on repeaters with odd splits, or communicating with astronauts on orbitingspace vehicles, it may be necessary to use non-standard splits between the receive andtransmit frequency. If the application is infrequent enough not to warrant the dedication ofa memory channel for this purpose, the “VFO Split” mode may be used. Here is the proce-dure for going Split:1. Press the [VFO(PRI)] key, as needed, to select VFO-A. Set VFO-A for the desiredreceiving (downlink) frequency (e.g.145.800 MHz).2. Now press the [VFO(PRI)] key, and set VFO-B for the desired transmit (uplink) fre-quency (e.g. 144.490 MHz).3. Press the [VFO(PRI)] key once more to re-establish VFO-A as the “Main” (receive)VFO.4. Press the [SET( )EMG] key momentarily to enter the Set mode.5. Rotate the DIAL to select Set Mode Item 50: VFO.SPL.6. Press the [F] key, then rotate the DIAL to set this function “VSP.ON.”7. Press the PTT switch once to save the new setting and exit tonormal operation.8. You will now be operating in the Split mode. When you pressthe PTT switch to transmit, you will observe that VFO-A and VFO-B will reversepositions. The VFO selection indicator “-b-” will blink while the transceiver is trans-mitting, this means that the VFO Split feature is now activated.
VX-127 OPERATING MANUAL229. If you need to modify the VFO-B (transmit) frequency (for Doppler Shift correction,etc.), just press the [VFO(PRI)] key, then make the necessary change, then press[VFO(PRI)] key once more to restore VFO-A to the “receive VFO” position.10. When you have finished with Split operation, re-enter the Set mode, and change SetMode Item 50: VFO.SPL to “VSP.OFF.”A split frequency pair set up via the VFO Split feature cannot be stored directly into memory.You can, however, store odd frequency pairs using a different (slightly simpler) procedure.See page 29.VFO SPLIT MODEREPEATER OPERATION
VX-127 OPERATING MANUAL 23CTCSS/DCS/EPCS OPERATIONCTCSS OPERATIONMany repeater systems require that a very-low-frequency audio tone be superimposed onyour FM carrier in order to activate the repeater. This helps prevent false activation of therepeater by radar or spurious signals from other transmitters. This tone system, called“CTCSS” (Continuous Tone Coded Squelch System), is included in your VX-127, and isvery easy to activate.CTCSS setup involves two actions: setting the Tone Mode and then setting of the ToneFrequency. These actions are set up by Set mode.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 44: SQL.TYP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob so that “TONE” indication appears on thedisplay; this activates the CTCSS Encoder, for access to repeat-ers requiring a CTCSS tone.5. Rotation of the DIAL knob one more “click” in step “2” abovewill cause the “TSQL” notation to appear. When “TSQL” is dis-played, this means that the Tone SQueLch system is active, whichmutes your VX-127’s receiver until it receives a call from an-other radio sending out a matching CTCSS tone. This can help keep your radio quietuntil a specific call is received, which may be helpful while operating in congestedareas of the band.1) You may notice a “REV TN” indication on the display while you rotatethe DIAL knob in this step; this means that the Reverse Tone Squelchsystem is active, which mutes your VX-127’s receiver (instead of openingthe squelch) when it receives a call from the radio sending a matched CTCSS tone.The “ ” icon will blink on the display when the Reverse Tone Squelch system isactivated.2) You may notice the “DCS” and “ECS” indications on the display while you rotatethe DIAL knob still more. We’ll discuss the Digital Code Squelch system (for “DCS”)and Enhanced Paging & Code Squelch (for “ECS”) later.6. When you have made your selection of the CTCSS tone mode, press the [F] key tosave the new setting.7. Rotate the DIAL knob to select Set Mode Item 46: TN FRQ.8. Press the [F] key momentarily to enable adjustment of the CTCSSfrequency.9. Rotate the DIAL knob until the display indicates the Tone Fre-quency you need to be using (ask the repeater owner/operator ifyou don’t know the tone frequency).
VX-127 OPERATING MANUAL247. When you have made your selection, pressthe [F] key momentarily, then press thePTT switch to save the new settings andexit to normal operation. This is differentthan the usual method of restoring nor-mal operation, and it applies only to theconfiguration of the CTCSS/DCS fre-quencies.Your repeater may or may not re-transmit a CTCSS tone - some systems justuse CTCSS to control access to the repeater, but don’t pass it along whentransmitting. If the S-Meter deflects, but the VX-127 is not passing audio,repeat steps “1” through “4” above, but rotate the DIAL so that “TSQ” disappears - thiswill allow you to hear all traffic on the channel being utilized.DCS OPERATIONAnother form of tone access control is Digital Code Squelch, or DCS. It is a newer, moreadvanced tone system which generally provides more immunity from false paging thandoes CTCSS. The DCS Encoder/Decoder is built into your VX-127, and operation is verysimilar to that just described for CTCSS. Your repeater system may be configured forDCS; if not, DCS is frequently quite useful in Simplex operation if your friend(s) usetransceivers equipped with this advanced feature.Just as in CTCSS operation, DCS requires that you set the Tone Mode to DCS and thatyou select a tone code.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 44: SQL.TYP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob until the “DCS” indication appears on thedisplay; this activates the DCS Encoder/Decoder.5. Press the [F] key to save the new setting.6. Rotate the DIAL knob to select Set Mode Item 13: DCS.COD.7. Press the [F] key momentarily to enable adjustment of the DCScode.8. Rotate the DIAL knob to select the desired DCS Code (a three-digit number). Ask the repeater owner/operator if you don’t knowDCS Code; if you are working simplex, just set up the DCS Codeto be the same as that used by your friend(s).9. When you have made your selection, press the [F] key momen-CTCSS OPERATIONCTCSS/DCS/EPCS OPERATIONCTCSS TONE FREQUENCY (Hz)  67.0   69.3   71.9   74.4   77.0   79.7  82.5   85.4   88.5   91.5   94.8   97.4100.0 103.5 107.2 110.9 114.8 118.8123.0 127.3 131.8 136.5 141.3 146.2151.4 156.7 159.8 162.2 165.5 167.9171.3 173.8 177.3 179.9 183.5 186.2189.9 192.8 196.6 199.5 203.5 206.5210.7 218.1 225.7 229.1 233.6 241.8250.3 254.1 – – – –
VX-127 OPERATING MANUAL 25CTCSS/DCS/EPCS OPERATIONtarily, then press the PTT switch to savethe new settings and exit to normal op-eration.Remember that the DCS is an En-code/Decode system, so your re-ceiver will remain muted until amatching DCS code is received on an incom-ing transmission. Switch the DCS off whenyou’re just tuning around the band!TONE SEARCH SCANNINGIn operating situations where you don’t know the CTCSS or DCS tone being used byanother station or stations, you can command the radio to listen to the incoming signal andscan in search of the tone being used. Two things must be remembered in this regard:You must be sure that your repeater uses the same tone type (CTCSS vs. DCS).Some repeaters do not pass the CTCSS tone; you may have to listen to the station(s)transmitting on the repeater uplink (input) frequency in order to allow Tone SearchScanning to work.To scan for the tone in use:1. Set the radio up for either CTCSS or DCS Decoder operation (see the previous discus-sions). In the case of CTCSS, “ ” will appear on the display; in the case of DCS,“” will appear on the display.2. Press the [SET( )EMG] key momentarily to enter the Set mode.3. Rotate the DIAL knob to select Set Mode Item 44: SQL.TYP when TONE SQL isselected, or select Set Mode Item 13: DCS.COD when DCS is selected4. Press the [F] key momentarily to enable adjustment of the se-lected Set Mode Item.5. Press and hold in the [(MHz)] or [(MHz)] key for one sec-ond to start scanning for the incoming CTCSS or DCS tone/code.6. When the radio detects the correct tone or code, it will halt onthat tone/code, and audio will be allowed to pass. Press the [F]key to lock in that tone/code, then press the [F] key followed by the PTT switch to exitto normal operation.If the Tone Scan feature does not detect a tone or code, it will continue toscan indefinitely. When this happens, it may be that the other station is notsending any tone. You can press the PTT switch to halt the scan at any time.DCS OPERATIONDCS CODE023 025 026 031 032 036 043 047 051 053054 065 071 072 073 074 114 115 116 122125 131 132 134 143 145 152 155 156 162165 172 174 205 212 223 225 226 243 244245 246 251 252 255 261 263 265 266 271274 306 311 315 325 331 332 343 346 351356 364 365 371 411 412 413 423 431 432445 446 452 454 455 462 464 465 466 503506 516 523 526 532 546 565 606 612 624627 631 632 654 662 664 703 712 723 731732 734 743 754 – – – – – –
VX-127 OPERATING MANUAL26You also can press the MONI key during Tone Scanning to listen to the (muted) signalfrom the other station. When you release the MONI key, Tone Scanning will resume afterabout a second. Tone Scanning works either in the VFO or Memory modes.EPCS (ENHANCED PAGING & CODE SQUELCH)The VX-127 includes an Enhanced CTCSS tone encoder/decoder and a dedicated micropro-cessor providing paging and selective calling features. This allows you to place a call to aspecific station (Paging), and to receive calls of your choice directed only to you (Code Squelch).The paging and code squelch systems use two pairs of (alternately switched) CTCSS toneswhich are stored in the pager memories. Basically, your receiver remains silent until itreceives the CTCSS tone pair that matches those stored in the Receiving Pager Memory.The squelch then opens so the caller is heard, and the paging ringer immediately sounds, ifactivated. When you close the PTT switch to transmit, the CTCSS tone pair which isstored in the Transmitting Pager Memory will be transmitted automatically.On the paged radio, the squelch will close automatically after the incoming page ends.Storing the CTCSS Tone Pairs for EPCS Operation1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 18: ECS.CDRfor the Receiving CTCSS Tone Pair or Set Mode Item 19:ECS.CDT for the Transmitting CTCSS Tone Pair.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set the CTCSSTone number which corresponds to the firsttone of the CTCSS Tone Pair.5. Press the [(MHz)] or [(MHz)] key,then rotate the DIAL knob to set the CTCSSTone number whichcorresponds to the sec-ond tone of the CTCSSTone Pair.6. Press the PTT switch tosave the new settingand exit to normal op-eration.CTCSS/DCS/EPCS OPERATIONHz67.069.371.974.477.079.782.585.488.591.5No.01020304050607080910Hz94.897.4100.0103.5107.2110.9114.8118.8123.0127.3No.11121314151617181920Hz131.8136.5141.3146.2151.4156.7159.8162.2165.5167.9No.21222324252627282930Hz171.3173.8177.3179.9183.5186.2189.9192.8196.6199.5No.31323334353637383940Hz203.5206.5210.7218.1225.7229.1233.6241.8250.3254.1No.41424344454647484950CTCSS TONE NUMBERTONE SEARCH SCANNING
VX-127 OPERATING MANUAL 27The VX-127 does not recognize the order of the 1st tone and the 2nd tone. Inother words, for example, the VX-127 considers both CTCSS pairs “10, 35”and “35, 10” to be identical.Activating the Enhanced Paging & Code Squelch System1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 44: SQL.TYP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob until the “ECS” indication appears on thedisplay; this activates the Enhanced Paging & Code SquelchSystem.5. Press the [F] key momentarily, then press the PTT switch tosave the new setting.6. To disable the Enhanced Paging & Code Squelch, just repeat the above procedure,rotating the DIAL knob to select “OFF” in step 4 above.When the Enhanced Paging & Code Squelch feature is activated, the“” icon will blink on the display.CTCSS/DCS/EPCS BELL OPERATIONDuring CTCSS Decode, DCS, or EPCS operation, you may set up the VX-170 such that aringing “bell” sound alerts you to the fact that a call is coming in. Here is the procedure foractivating the CTCSS/DCS/EPCS Bell:1. Set the transceiver up for CTCSS Decode (“Tone Squelch”), DCS, or EPCS opera-tion, as described previously.2. Adjust the operating frequency to the desired channel.3. Press the [SET( )EMG] key momentarily to enter the Set mode.4. Rotate the DIAL knob to select Set Mode Item 7: BELL.5. Press the [F] key momentarily to enable adjustment of this Item.6. Rotate the DIAL knob to set the desired number of rings of theBell. The available choices are “1 T,” “3 T,” “5 T,” or “8 T”rings, CONT (continuous ringing), or OFF.7. Press the PTT switch momentarily to save the new setting andexit to normal operation.When you are called by a station whose transceiver is sending a CTCSS tone, DCS code,or CTCSS code pair which matches that set into your Decoder, theBell will ring in accordance with this programming. When the CTCSS/DCS/EPCS Bell is activated, the “ ” icon will appear at the upperright corner on the LCD.CTCSS/DCS/EPCS OPERATIONEPCS (ENHANCED PAGING & CODE SQUELCH)
VX-127 OPERATING MANUAL28SPLIT TONE OPERATIONThe VX-127 can be operated in a Split Tone configuration via the Set mode.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 43: SPLIT.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the  DIAL knob to select ON (to enable the Split Tonefeature).5. Press the PTT switch momentarily to save the new setting andexit to normal operation.When the Split Tone feature is activated, you can see the following additional parametersfollowing the “DCS” parameter (while selecting the Set Mode Item 44: SQL.TYP):D: DCS Encode only (the “ ” icon will blink during operation)T DCS: Encodes a CTCSS Tone and Decodes a DCS code(the “ ” icon will blink and the “ ” icon will appear during operation)D TSQL: Encodes a DCS code and Decodes a CTCSS Tone(the “ ” icon will appear and the “ ” icon will blink during operation)Select the desired operating mode from the selections shown above.TONE CALLING (1750 HZ)If the repeaters in your country require a 1750-Hz burst tone for access (typically in Eu-rope), you can set the MONI key to serve as a “Tone Call” switch instead. To change theconfiguration of this switch, we again use the Set Mode to help us.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 27: M/T-CL.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select “T-CALL” on the display.5. Press the PTT switch to save the new setting and exit to normaloperation.To access a repeater, press and hold in the MONI key for the amount of time specified bythe repeater owner/operator. The transmitter will automatically be activated, and a 1750-Hz audio tone will be superimposed on the carrier. Once access to the repeater has beengained, you may release the MONI key, and use the PTT switch for activating the transmit-ter thereafter.CTCSS/DCS/EPCS OPERATION
VX-127 OPERATING MANUAL 29MEMORY MODEThe VX-127 provides a wide variety of memory system resources. These include:200 “Standard” memory channels, numbered “1” through “200.”A “Home” channel, providing storage and quick recall of one prime frequency.10 sets of band-edge memories, also known as “Programmable Memory Scan” chan-nels, labeled “L1/U1” through “L10/U10.”10 Memory Banks, labeled “BANK 1” through “BANK10.” Each Memory Bankcan be assigned up to 200 channels from the “standard” memory channels.10 “Weather Broadcast” Channels.MEMORY STORAGE1. Select the desired frequency, while operating in the VFO mode. Be sure to set up anydesired CTCSS or DCS tones, as well as any desired repeater offset, now. The powerlevel may also be set at this time, if you wish to store it.2. Press and hold in the [F] key for one second.3. Within ten seconds of releasing the [F] key, you need to make a decision regardingchannel storage. The microprocessor will automatically select the next-available “free”channel (a memory register on which no data has been stored), so you may not wish tomake any change; if this is the case, proceed to step 4. If you wish to select a differentchannel number into which to store the data, rotate the DIAL knob to select the desiredmemory channel. You may jump 10 memory channels, if you’re in a hurry (11  21 31 …) by pressing the [VFO(PRI)] key (multiple times, if necessary).4. Press the [F] key once more to store the frequency into memory.5. You still will be operating in the “VFO” mode, so you may now enter other frequen-cies, and store them into additional memory locations, by repeating the above process.Storing Independent Transmit Frequencies (“Odd Splits”)All memories can store an independent transmit frequency, for operation on repeaters withnon-standard shift. To do this:1. Store the receive frequency using the method already described under MEMORYSTORAGE (it doesn’t matter if a repeater offset is active).2. Tune to the desired transmit frequency, then press and hold in the [F] key for onesecond.3. Within ten seconds of releasing the [F] key, rotate the DIAL knob to select the samememory channel number as used in step “1” above.4. Press and hold in the PTT switch, then press the [F] key once more momentarily whileholding the PTT switch in (this does not key the transmitter).Whenever you recall a memory which contains inde-pendently-stored transmit and receive frequencies, the“” indication will appear in the display.
VX-127 OPERATING MANUAL30MEMORY MODEMEMORY RECALL1. While operating in the VFO mode, press the [MR(SKIP)] key toenter the Memory mode.2. Rotate the DIAL knob to select the desired channel.3. To return to the VFO mode, press the [VFO(PRI)] key.HOME CHANNEL MEMORYA special one-touch “HOME” channel is available, to allow quick recall of a favoriteoperating frequency.Home Channel storage is simple to accomplish:1. Change the setting of Set Mode Item 33: REV/HM from “REV” to “HOME,” if it isnot already set to this option (see page 79).2. Select the desired frequency, while operating in the VFO mode. Be sure to set up anydesired CTCSS or DCS tones, as well as any desired repeater offset. The power levelmay also be set at this time, if you wish to store it.3. Press and hold in the [F] key for one second.4. While the memory channel number is blinking, just press the [REV(HOME)] key. Thefrequency and other data (if any) will now be stored in the special HOME channelregister.5. To recall the HOME channel, press the[REV(HOME)] key momentarily whileoperating either in the VFO or MR mode.“USA” VERSION “EXP” VERSION
VX-127 OPERATING MANUAL 31MEMORY MODELABELING MEMORIESYou may wish to append an alpha-numeric “Tag” (label) to a memory or memories, to aidin recollection of the channel’s use (such as a club name, etc.). This is easily accomplishedusing the Set Mode.1. Recall the memory channel on which you wish to append a label.2. Press the [SET( )EMG] key momentarily to enter the Set mode.3. Rotate the DIAL knob to select Set Mode Item 29: NM WRT.4. Press the [F] key momentarily to display the previouslystored label (if any).5. Press the [F] key again to clear any previous label.6. Rotate the DIAL knob to select the first digit of the desiredlabel.7. Press the [F] key to move to the next character.8. If you make a mistake, press the [(MHz)] key to back-space the cursor, then re-enter the correct letter, number,or symbol.9. Repeat steps 5 through 7 to program the remaining letters,numbers, or symbols of the desired label. A total of six charac-ters may be used in the creation of a label.10. When you have programmed a label which is under 6 characters,press and hold in the [F] key for one second to confirm the label (if the label is exactly 6characters in length, you do not need to press and hold in [F] key).11. When you have completed the creation of the label, press thePTT switch to save the label and return to the memory recallmode with labeled (alpha-numeric “Tag”) display.To disable the alpha-numeric Tag (enabling the frequency display):1. Set the VX-127 to the “MR” (Memory Recall) mode, and recall the memory channelon which you wish to disable the alpha-numeric Tag.2. Press the [SET( )EMG] key momentarily to enter the Set mode.3. Rotate the DIAL knob to select the Set Mode Item 28: NAME.4. Press the [F] key momentarily to enable adjustment of this Item’ssetting.5. Rotate the DIAL knob to set this Set Mode Item to “FREQ”(enabling the frequency display).6. Press the PTT switch to save the new setting and activate thealpha-numeric Tag.To display the alpha-numeric Tag again, just repeat the above procedure, rotating the  DIALknob to select “ALPHA” in step 5 above.Set Mode Item 28:NAME is not applied to all memory channels at once (justthe channel on which you currently are operating).
VX-127 OPERATING MANUAL32MEMORY OFFSET TUNINGOnce you have recalled a particular memory channel, you may easily tune off that channel,as though you were in the “VFO” mode.1. With the VX-127 in the “MR” (Memory Recall) mode, selectthe desired memory channel.2. Press the [MR(SKIP)] key momentarily to activate the “MemoryTuning” feature. The Memory Channel number will be replacedby “tun.” And if you have an alpha-numeric Tag displayed onthe memory channel, the display will automatically revert to dis-play of the operating frequency, so you can navigate withouthaving to enter the Menu to change the display configuration.3. Rotate the DIAL knob, as desired, to tune to a new frequency.The synthesizer steps selected for VFO operation on the currentband will be the steps used during Memory Tuning.4. If you wish to return to the original memory frequency, just pressthe [MR(SKIP)] key momentarily. The display will revert todisplay of the alpha-numeric Tag (if any) that may have origi-nally appeared on the LCD.5. If you wish to store a new frequency set during Memory Tuning, just press and hold inthe [F] key for one second, per normal memory storage procedure. The microproces-sor will automatically set itself to the next-available clear memory location, and youthen press [F] again to lock in the new frequency.1) If you want to replace the original memory contents with those of the newfrequency, be sure to rotate the DIAL knob to the original memory channelnumber!2) Any required CTCSS/DCS changes, or repeater offset modifications, must be donebefore storing the data into the new (or original) memory channel location.DELETING MEMORIESYou may delete any of the memories (except for Memory Channel “1” and the HomeChannel). The procedure for deleting a channel is quite simple.1. Press the [MR(SKIP)] key, if needed, to enter the MR mode.2. Press and hold in the [F] key for one second, then rotate the DIAL knob to select thememory channel to be deleted.3. Press the [MR(SKIP)] key momentarily. The display will revert to memory channel#1. The previously-selected memory will be deleted.Important Notice! Once deleted, the channel data cannot be recovered!MEMORY MODE
VX-127 OPERATING MANUAL 33MEMORY MODEMEMORY BANK OPERATIONThe large number of memories available in the VX-127 could be difficult to utilize withoutsome means of organizing them. Fortunately, the VX-127 includes provision for dividingthe memories into as many as ten Memory Groups, so you can categorize the memories ina manner convenient to you.Assigning Memories to a Memory Bank1. Recall the memory channel to be assigned to a Memory Bank.2. Press and hold in the [VFO(PRI)] key for one second, then ro-tate the DIAL knob to select the Memory Bank number you wantas the Memory Bank for this channel (“BANK 1” ~“BANK10”).3. Press and hold in the [F] key for one second to copy the memorychannel data into the Memory Bank.1) You may assign one memory channel into multiple Memory Banks.2) The PMS memory channels (L1/U1 through L10/U10) may not be as-signed to a Memory Bank.Memory Bank Recall1. Press the [MR(SKIP)] key, if needed, to enter the Memory Re-call mode.2. Press and hold in the [VFO(PRI)] key, then rotate the DIALknob to select the desired Memory Bank (“BANK 1” through“BANK10”).3. Press the [MR(SKIP)] key momentarily; now, as you rotate theDIAL knob to select memories, you will observe that you canonly select memory channels in the current memory bank. The“” indication will appear at the left side of the frequency display while operatingwithin a Memory Bank.4. To change to another Memory Bank, press and hold in the [VFO(PRI)] key, rotate theDIAL knob to select the new Memory Bank, then press the [MR(SKIP)] key momentarily.5. To exit from Memory Bank operation, select “NOBANK” instep 4 above. You are now in the “standard” Memory Recallmode, without utilization of the Memory Banks. The memoriesstored in the various Banks will remain in those banks, however;you do not need to store them again.Removing Memories from a Memory Bank1. Recall the memory channel to be removed from a Memory Bank.2. Press and hold in the [VFO(PRI)] key for one second, then press and hold in the [F] keyto remove the memory channel data from the Memory Bank.
VX-127 OPERATING MANUAL34MOVING MEMORY DATA TO THE VFOData stored on memory channels can easily be moved to the last selected VFO, if you like.1. Select the memory channel containing the frequency data to be moved to the VFO.2. Press the [MR(SKIP)] key momentarily to activate the “Memory Tune” feature tem-porarily, then press and hold in the [VFO(PRI)] key for one second. The data will nowhave been copied to the last selected VFO, although the original memory contents willremain intact on the previously-stored channel.If a Split Frequency Memory channel was transferred, the TX frequency will be ignored(you will be set up for Simplex operation on the Receive frequency).MEMORY ONLY MODEOnce memory channel programming has been completed, you may place the radio in a“Memory Only” mode, whereby VFO operation is impossible. This may be particularlyuseful during public-service events, where a number of operators may be using the radiofor first time, and ultimate simplicity of channel selection is desired.To place the radio into the Memory Only mode:1. Turn the radio off.2. Press and hold in the MONI switch (just below the PTT switch)while turning the radio on.3. Rotate the DIAL knob to select the “F5 M-ONLY” option, thenpress the [F] key.To return to normal operation, repeat the above power-on procedure.MEMORY MODE
VX-127 OPERATING MANUAL 35NOTE
VX-127 OPERATING MANUAL36The VX-127 allows you to scan just the memory channels, the entire operating band, or aportion of that band. It will halt on signals encountered, so you can talk to the station(s) onthat frequency, if you like.Scanning operation is basically the same in each of the above modes. Before you begin,take a moment to select the way in which you would like the scanner to resume scanningafter it halts on a signal.Setting the Scan-Resume TechniqueThree options for the Scan-Resume mode are available:BUSY: In this mode, the scanner will halt on a signal it encounters. Two seconds after thecarrier has dropped because the other station(s) ceased transmission, the scannerwill resume. In the case of constant-carrier signals like Weather Station broad-casts, the scanner will likely remain on this frequency indefinitely.HOLD: In this mode, the scanner will halt on a signal it encounters. It will not restartautomatically; you must manually re-initiate scanning if you wish to resume.TIME: In this mode, the scanner will halt on a signal it encounters, and will hold there forfive seconds. If you do not take action to disable the scanner within that timeperiod, the scanner will resume even if the stations are still active.To set the Scan-Resume mode:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 32: RESUME.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired scan-resume mode.5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.The default condition for this Set Mode Item is “BUSY.”SCANNINGSETTING THE SQUELCH LEVEL DURING ACTIVE SCANNING OPERATIONThe VX-127 allows adjustment of the Squelch level “on the fly” while you are scanning.1. While the scanner is engaged, press the [F] key, then pressthe MONI switch (the current squelch level (e.g. “S 3”)will appear in fine print above the frequency display).2. Rotate the DIAL to select the desired Squelch level.3. Press the PTT switch momentarily to save the new setting and exit to normaloperation. In this case, pressing the PTT switch this one time will not causingscanning to stop.
VX-127 OPERATING MANUAL 37SCANNINGVFO SCANNINGThe VX-127 provides two VFO scanning functions: “Manual VFO Scanning” and “Pro-grammed VFO Scanning.”Manual VFO Scan1. Select the VFO mode by pressing the [VFO(PRI)] key, if necessary.2. Press and hold in either the [(MHz)] or [(MHz)] key for one second to initiateupward or downward scanning, respectively.3. If and when the scanner encounters a signal strong enough to open the squelch, thescanner will halt temporarily; the decimal point of the frequency display will blinkduring this “Pause” condition.4. The scanner will then resume according to the Scan-Resume mode selected in theprevious section.5. To cancel scanning, press the PTT switch or [VFO(PRI)] key.Programmed VFO Scan1. Select the VFO mode by pressing the [VFO(PRI)] key, if necessary.2. Press and hold in the [VFO(PRI)] key for one second, then rotate the DIAL knob toselect the bandwidth for the Programmed VFO scanner. Available selections are ±1MHz, ±2 MHz, ±5 MHz, PMS-x, and ALL.PMS-x: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page 41 for details.ALL: The scanner will sweep all frequencies.3. Press the [VFO(PRI)] key momentarily to save the new setting and exit to normaloperation.4. Press and hold in the [MR(SKIP)] key for one second to start scanning.5. If and when the scanner encounters a signal strong enough to openthe squelch, the scanner will halt temporarily; the decimal point ofthe frequency display will blink during this “Pause” condition.6. The scanner will then resume according to the Scan-Resumemode selected in the previous section.7. To cancel scanning, press the PTT switch or the [VFO(PRI)] key.When you start the Programmed VFO Scanner, the VX-127 will be changingfrequency in the upward direction. If you want to change direction of thescan while it is underway, rotate the DIAL knob one click in the oppositedirection (in this case, one click counter-clockwise). You’ll see the scanner turn aroundand change frequency downward!
VX-127 OPERATING MANUAL38MEMORY SCANNINGMemory scanning is similarly easy to initiate:1. Select the Memory mode by pressing the [MR(SKIP)] key, if necessary.2. Press and hold in either the [(MHz)] or [(MHz)] key for one second to initiateupward or downward scanning, respectively.3. If and when the scanner encounters a signal strong enough to open the squelch, thescanner will halt temporarily; the decimal point of the frequency display will blinkduring this “Pause” condition.4. The scanner will then resume according to the Scan-Resume mode selected in theprevious section.5. To cancel scanning, press the PTT switch or [MR(SKIP)] key.How to Skip (Omit) a Channel during Memory Scan OperationAs mentioned previously, some continuous-carrier stations like a Weather Broadcast sta-tion will seriously impede scanner operation if you are using the “Carrier Drop” Scan-Resume mode, as the incoming signal will not pause long enough for the transceiver toresume scanning. Such channels may be “Skipped” during scanning, if you like:1. Recall the Memory Channel to be skipped during scanning.2. Press the [F] key, then press the [MR(SKIP)] key to enter the “Skip” channel-selec-tion mode.3. Rotate the DIAL knob so as to select “SKIP.” The current MemoryChannel will now be ignored during scanning. The “ONLY” se-lection is used for “Preferential Memory Scan,” described in thenext section.4. When you have made your selection, press the PTT switch to save the setting and exitto normal operation.When you recall the “skipped” memory channel manually, a small“” icon will appear at the left of the memory channel number, indi-cating it is to be ignored during scanning.To re-institute a channel into the scanning loop, select “OFF” in step 3 above (the “Skipped”channel will, of course, still be accessible via manual channel selection methods using theDIAL knob in the MR mode, whether or not it is locked out of the scanning loop).SCANNING
VX-127 OPERATING MANUAL 39SCANNINGPreferential Memory ScanThe VX-127 also allows you to set up a “Preferential Scan List” of channels which you can“flag” within the memory system. These channels are designated by a blinking “” iconwhen you have selected them, one by one, for the Preferential Scan List.When you initiate memory scanning, beginning on a channel with the blinking “” iconappended, only those channels bearing the blinking “” icon will be scanned. If youinitiate scanning on a channel which does not have the blinking “” icon appended, youwill scan all channels including those with the blinking “” icon appended.Here is the procedure for setting up and using the Preferential Scan List:1. Recall the Memory Channel which you wish to add to the Preferential Scan List.2. Press the [F] key, then press the [MR(SKIP)] key to enter the “Skip” channel-selec-tion mode.3. Rotate the DIAL knob so as to select “ONLY.”4. When you have made your selection, press the PTT switch tosave the setting and exit to normal operation.5. To remove a channel from the Preferential Scan List, just repeat the above procedure,rotating the DIAL knob to select “OFF” in step 3 above.To initiate Preferential Memory Scan:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 39: SCN MD.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob so as to select “ONLY.”5. Press the PTT switch to save the setting and exit to normal op-eration.6. Now, press and hold in either the [(MHz)] or [(MHz)] key for one second toinitiate the Preferential Memory Scan. Only the channels which have the blinking “”icon appended to the channel number will be scanned.7. To cancel the Preferential Memory Scan, just repeat the above procedure, rotating theDIAL knob to select “MEM” in step 4 aboveMEMORY SCANNING
VX-127 OPERATING MANUAL40Memory Bank ScanWhen the Memory Bank feature is engaged, the scanner sweeps only memory channels inthe current Memory Bank. However, if the Memory Bank Link Scan feature is enabled,you may sweep the memory channels in several Memory Banks which you have selected.To enable the Memory Bank Link Scan feature:1. Set the radio to the Memory mode by pressing the [MR(SKIP)] key, if necessary.2. Press and hold in the [VFO(PRI)] key for one second, then rotate the DIAL knob toselect the first Memory Bank (“BANK 1” ~ “BANK10”) you wish to sweep usingMemory Bank Link Scan.3. Press the [F] key momentarily. The current Memory Bank willnow be swept during Memory Bank Scan. A “decimal point”will be appended between the “N” and “K” of the Memory Banknumber indication (such as BAN.K 2).4. Repeat steps 2 and 3 above, to append the “decimal point” to any other Memory Banksyou wish to sweep.5. Now, press and hold in the [MR(SKIP)] key for one second to initiate the MemoryBank Link Scan.6. To remove a Memory Bank from the Memory Bank Link Scan, repeat steps 2 and 3above, to delete the “decimal point” from the Memory Bank number indication.SCANNINGMEMORY SCANNING
VX-127 OPERATING MANUAL 41SCANNINGPROGRAMMABLE (BAND LIMIT) MEMORY SCAN (PMS)This feature allows you to set sub-band limits for either scanning or manual VFO opera-tion. For example, you might wish to set up a limit (in North America) of 144.300 MHz to148.000 MHz so as to prevent encroachment into the SSB/CW “Weak Signal” portion ofthe band below 144.300 MHz. Here’s how to do this:1. Set the radio to the VFO mode by pressing the [VFO(PRI)] key, if necessary.2. Using the techniques learned earlier, store (per the above concept) 144.300 MHz intoMemory Channel #L1 (the “L” designates the Lower sub-band limit).3. Likewise, store 148.000 MHz into Memory Channel #U1 (the “U” designates theUpper sub-band limit).4. Confirm the radio is in the VFO mode, press and hold in the [VFO(PRI)] key for onesecond, and rotate the DIAL knob to select the desired PMS frequency pair (PMSxx),then press the [VFO(PRI)] key.5. Now, press and hold in the [MR(SKIP)] key for one second to initiate Programmable(Band Limit) Memory Scan. Scanning will now be limited within the just-programmedrange.6. 10 pairs of Band Limit memories, labeled L1/U1 through L10/U10 are available. Youtherefore can set upper and lower operation limits in multiple segments on the band, ifyou like.
VX-127 OPERATING MANUAL42“PRIORITY CHANNEL” SCANNING (DUAL WATCH)The VX-127’s scanning features include a two-channel scanning capability which allowsyou to operate on a VFO or Memory channel, while periodically checking a user-definedMemory Channel for activity. If a station is received on the Memory Channel which isstrong enough to open the Squelch, the scanner will pause on that station in accordancewith the Scan-Resume mode set via Set Mode Item 32: RESUME. See page 36.Here is the procedure for activating Priority Channel Dual Watch operation:VFO Priority1. Recall the memory channel you wish to use as the “Priority” frequency.2. Now, set the radio to the VFO mode by pressing the [VFO(PRI)] key.3. Press the [F] key, then press the [VFO(PRI)] key to activate theVFO Priority mode. The display will remain on the VFO fre-quency, but every five seconds the radio will check the PriorityChannel (memory channel) for activity.4. Press [F]  [VFO(PRI)] again to disable the VFO Priority mode.Memory Channel Priority1. Store the frequency you wish to be the “Priority” Channel into memory channel “1.”2. Now, set the radio for operation on another memory channel.3. Press the [F] key, then press the [VFO(PRI)] key to activate theMemory Priority mode. The display will remain on the currentmemory channel frequency, but every five seconds the radio willcheck the Priority Channel (memory channel “1”) for activity.4. Press [F]  [VFO(PRI)] again to disable the Memory Priority mode.When the Memory Bank feature is activated, the VX-127 will check the lowest  num-bered memory channel in the current Memory Bank as the Priority Channel.HOME Channel Priority1. Recall the memory channel you wish to use as the “Priority” frequency.2. Now set the radio for operation on the HOME channel by pressing the [F] key fol-lowed by [REV(HOME)].3. Press the [F] key, then press the [VFO(PRI)] key to activate theHOME Priority mode. The display will remain on the HOMEchannel frequency, but every five seconds the radio will checkthe Priority Channel (memory channel) for activity.4. Press [F]  [VFO(PRI)] again to disable the HOME Priority mode.SCANNING
VX-127 OPERATING MANUAL 43VFO-VFO Dual Watch1. Press the [VFO(PRI)] key to switch the VFO mode, if needed.2. Press the [F] key, then press and hold in the [VFO(PRI)] key for one second. The VX-127 will now periodically change from VFO-A frequency to the VFO-B frequency,checking for activity on each VFO for 0.2 second interval.3. Press the [VFO(PRI)] key to disable the VFO-VFO Dual Watch.SCANNING“PRIORITY CHANNEL” SCANNING (DUAL WATCH)Priority Revert ModeDuring Priority channel operation (Dual Watch), a special feature is available whichwill allow you to move to the Priority channel instantly, without waiting for activity toappear on the Priority channel.When this feature is enabled, and Priority monitoring is engaged, just press the PTTswitch; operation will instantly revert to the Priority channel.To enable the Priority Revert operation:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 36: PRI.RVT.3. Press the [F] key momentarily to enable adjustment of thisSet Mode Item.4. Rotate the DIAL knob to set this Set Mode Item to “RVT.ON.”5. When you have made your selection, press the PTT switchto save the setting and exit to normal operation.6. To disable the Priority Revert operation, just repeat the above procedure, rotatingthe DIAL knob to select “RVT.OFF” in step 4 above.
VX-127 OPERATING MANUAL44AUTOMATIC LAMP ILLUMINATION ON SCAN STOPThe VX-127 will automatically illuminate the LCD/Keypad Lamp whenever the scannerstops on a signal; this allows you to see the frequency of the incoming signal better at night.Note that this will, of course, increase the battery consumption, so be sure to switch it offduring the day (the default condition for this feature is “ON”).The procedure for disabling the Scan Lamp is:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 40: SCN.LMP.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “OFF.”5. When you have made your selection, press the PTT switch tosave the setting and exit to normal operation.BAND EDGE BEEPERThe  VX-127 will automatically “beep” when a band edge is encountered during scanning(either in standard VFO scanning or during PMS operation). You may also enable thisfeature (band edge beeper) to operate when the frequency reaches the band edge whiletuning using the DIAL knob.The procedure for enabling the Band-Edge Beeper is:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 20: EDG.BEP.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “BEP. ON.”5. When you have made your selection, press the PTT switch tosave the setting and exit to normal operation.SCANNING
VX-127 OPERATING MANUAL 45NOTE
VX-127 OPERATING MANUAL46EMERGENCY CHANNEL OPERATIONThe VX-127 includes an “Emergency” feature which may be useful if you have someonemonitoring on the same frequency as your transceiver’s “Home” channel. See page 30 fordetails on setting up the Home channel.The “Emergency” feature is activated by pressing and holding in the [SET( )EMG] keyfor one second. When this is done, (A) the radio is placed on the Home channel, (B) itemits a loud “Alarm” sound (the volume is controlled by the VOL/PWR knob), (C) itflashes the LCD/keypad lamp, (D) if you press the PTT switch, you will disable the Emer-gency feature temporarily; you can then transmit on the Home channel, and (E) two sec-onds after the PTT switch release, the Emergency feature will resume.To disable the “Emergency” feature, press the [F] key momentarily or turn the radio off byrotating the VOL/PWR knob fully counter-clockwise into the click-stop position.Use this feature if you are out for a walk and want a quick way of alerting a family memberas to a dangerous situation. The alarm sound may discourage an attacker and allow you toescape.1) Be sure to arrange with a friend or family member to be monitoring on thesame frequency, as there will be no identification sent via the Emergencyalarm sound. And do not transmit the alarm tone except in a true emergency!2) The “Emergency” feature may be changed to another function via Set Mode Item 21:EMG S; see page 76 for details.EMERGENCY FEATURE
VX-127 OPERATING MANUAL 47EMERGENCY FEATUREEMERGENCY AUTOMATIC ID (EAI) FEATUREThe Emergency Automatic ID (EAI) feature can be used for searching for persons who areincapacitated in disasters like earthquakes, especially search-and-rescue personnel whomay have become injured in a debris field. In such cases, if another searcher sends out aunique command (CTCSS tone pair), the radio of the incapacitated party, who may not beable to speak or even press the PTT switch,  will automatically cause the injured party’sradio to transmit, so others may perform direction-finding and effect a rescue. The callsignof the incapacitated person will also be transmitted, to assist the rescue team.If an emergency group is working in a dangerous area, all members should engage the EAIfeature on their transceiver, so that others can provide assistance to a fallen team member,if necessary.The Emergency Automatic ID (EAI) Feature has two operating modes: (1) Interval modeand (2) Continuous mode.In the Interval mode, when the VX-127 receives the CTCSS tone pair which is stored inthe Receiving Pager Code Memory (configured via Set Mode Item 18: ECS.CDR) on thefrequency which is stored in Memory Channel “200” for more than five seconds, the radiowill automatically transmit a brief (0.5 second) beep tone every 2.5 seconds until the EAItimer expiration at the power level stored in that memory channel; it is NOT necessary forthe incapacitated person to press the PTT switch.In the Continuous mode, when the VX-127 receives the CTCSS tone pair which is storedin the Receiving Pager Code Memory (configured via Set Mode Item 18: ECS.CDR) on thefrequency which is stored in Memory Channel “200” for more than five seconds, the radiowill automatically transmit (with maximum microphone gain) continuously, until the EAItimer expiration, at the power level stored in that memory channel; it is NOT necessary forthe incapacitated person to press the PTT switch.Furthermore, if your call sign is stored in the radio via Set Mode Item 11: CW WRT and you haveenabled the CW identifier by Set Mode Item 10: CWID, the radio will transmit your callsign onthe air when the EAI feature is first engaged by the remote page, and every 10 minutes thereater.The “callsign” ID can be changed to any desired sequence of characters, such as a name.After sending the callsign or name, the radio will repeatedly transmit three tones for a user-defined period of time (between 1 and 30 minutes). The callsign or name will be transmit-ted every 10 minutes.
VX-127 OPERATING MANUAL48EMERGENCY AUTOMATIC ID (EAI) FEATUREThe Emergency Automatic ID (EAI) Feature requires that you (1) store the CTCSS TonePair into the Receiving Pager Memory (see page 26 for procedure), and (2) store the desiredcoordination frequency into Memory Channel “200” (see page 29 for procedure).To enable this feature:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 53: EAI.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired EAI mode (INTtervalEAI or CONtinuous EAI) and its transmit time (1-10, 15, 20,30, 40, and 50 minutes) or OFF.5. Press the PTT switch to save the new setting and exit to normal operation.6. To disable the Emergency Automatic ID feature, just repeat the above procedure, ro-tating the DIAL knob to select “OFF” in step 4 above.When the Emergency Automatic ID feature is activated, the “ ”icon will blink in the LCD.The VX-127 will ignore the EAI feature when the (1) the squelch is open, (2)there is an incoming the signal on the operating frequency, or (3) the operat-ing frequency is the same as the frequency which is stored in the MemoryChannel “200.”EMERGENCY FEATURE
VX-127 OPERATING MANUAL 49The Smart Search feature allows you to load frequencies automatically according to whereactivity is encountered by your radio. When Smart Search is engaged, the transceiver willsearch above and below your current frequency, storing active frequencies as it goes (with-out stopping on them even momentarily); these frequencies are stored into a special SmartSearch memory bank, consisting of 31 memories (15 above the current frequency, 15 be-low the current frequency, plus the current frequency itself).Two basic operating modes for Smart Search are available:SINGLE: In this mode, the transceiver will sweep the current band once in each directionstarting on the current frequency. All channels where activity is present will beloaded into the Smart Search memories; whether or not all 31 memories arefilled, the search will stop after one sweep in each direction.CONT: In this mode, the transceiver will make one pass in each direction as with One-Shot searching; if all 31 channels are not filled after the first sweep, however, theradio will continue sweeping until they are all filled.Starting the Smart Search Mode1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 38: S SRCH.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired Smart Search mode(see above).5. Press the [F] key momentarily to begin the Smart Search scanning.6. As active channels are detected, you will observe the number of “loaded” channelsincreasing in the regular memory channel window.7. Depending on the mode you set for Smart Search operation (“SINGLE” or “CONT”),the Smart Search scan will eventually terminate, and the LCDwill revert to Smart Search Memory Channel “C.”8. To recall the Smart Search memories, rotate the DIAL knob tochoose from among the frequencies stored by Smart Search.9. To return to normal operation, press the [VFO(PRI)] key.Smart Search is a great tool when visiting a city for the first time. You don’tneed to spend hours looking up repeater frequencies from a reference guide-book. . .just ask your VX-127 where the action is!SMART SEARCH OPERATION
VX-127 OPERATING MANUAL50The VX-127 can be used to access a “node” (repeater or base station) which is tied into theVertex Standard WIRES™ (Wide-Coverage Internet Repeater Enhancement System) net-work, operating in the “SRG” (Sister Radio Group) mode. Details may be found at theWIRES-II Web site: http://www.vxstd.com/en/wiresinfo-en/. This feature may also be usedto access other systems, as described below.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 23: INT CD.3. Press the [F] key to enable adjustment of this Set Mode Item.4. Rotate the DIAL knob to select the access number (CODE “0” ~“9,” “A,” “B,” “C,” “D,” “E (),” “F (#),”) corresponding tothe WIRES™ node to which you wish to establish an Internetlink (ask the node or repeater owner/operator if you don’t knowthe access number in the network).5. Press the [F] key momentarily to save the new setting.6. Rotate the DIAL knob to select Set Mode Item 22: I NET.7. Press the [F] key to enable adjustment of this Set Mode Item.8. Rotate the DIAL knob to set this Set Mode Item to “INT.COD”(thus activating the “WIRES™” mode).9. Press the PTT switch momentarily to save the new settings andexit to normal operation.10. The “ ” icon will appear in the upper right corner of the dis-play (thus activate the Internet Connection feature).11. With the Internet Connection feature activated (as in step 8above), the VX-127 will generate a brief (0.1 second) DTMF tone according to yourselection in step 4. This DTMF tone is sent at the beginning of every transmission toestablish or maintain the link to the local WIRES™ node operating in the SRG mode.12. To disable the Internet Connection feature, press the [F] key, then press the[WX(EMG) ] key (the “ ” icon will disappear from the display).If other users report that you always have a DTMF “beep” at the beginningof each transmission, and you are not operating in conjunction with Internetaccess, disable this function via step (12) above.INTERNET CONNECTION FEATURE
VX-127 OPERATING MANUAL 51INTERNET CONNECTION FEATUREYou may access other Internet Link Systems (including WIRES™ in the “FRG” mode)that use a DTMF string for access.1. Load the DTMF tones which you wish to use for Internet-link access into a DTMF Autodialmemory register. For purposes of this example, we will use “#123” as the access code.A. Press the [SET( )EMG] key momentarily to enter the Set mode.B. Rotate the DIAL knob to select Set Mode Item 17: DT WRT.C. Press the [F] key to enable adjustment of this Set Mode Item.D. Rotate the DIAL knob to select the DTMF Memory register(“d1” ~ “d9”) into which you wish to store the access code.E. Press the [F] key momentarily. The first digit will blink.F. Rotate the DIAL knob to select “F” (representing DTMF“#”: the first digit of the DTMF string).G. Press the [F] key momentarily to accept the first digit andmove to the second digit of the DTMF string.H. Repeat the previous steps until you have completed the ac-cess code (“#(F)123”).I.Press and hold in the [F] key for one second to save the setting.2. Press the PTT switch to exit to normal operation.3. Press the [SET( )EMG] key momentarily to enter the Set modeagain.4. Rotate the DIAL knob to select Set Mode Item 24: INT MR.5. Press the [F] key to enable adjustment of this Set Mode Item.6. Rotate the DIAL knob to select the DTMF access number (“d1” ~ “d 9”) corresponding to the Internet link repeater to whichyou wish to establish an Internet link, then press the [F] keymomentarily to lock in the selected access number.7. Rotate the DIAL knob to select Set Mode Item 22: I NET.8. Press the [F] key to enable adjustment of this Set Mode Item.9. Rotate the DIAL knob to set this Set Mode Item to “INT.MEM”(thus activating the “Other Internet Link System” mode).10. Press the PTT switch momentarily to save the new settings andexit to normal operation.11. The “ ” icon will appear in the upper right corner of the dis-play (thus activate the Internet Connection feature).12. Once the Internet Connection feature is activated per step 9 above,you may now press the [SET( )EMG] key, while you are trans-mitting, to send out the selected DTMF string (to establish thelink to the desired Internet-link mode).13. To disable the Internet Connection feature, press the [F] key, then press the[SET( )EMG] key (the “ ” icon will disappear from the display).To return to the WIRES™ mode, repeat steps 3 - 6 above, selecting “INT.COD” in step 9.
VX-127 OPERATING MANUAL52The ARTS™ feature uses DCS signaling to inform both parties when you and anotherARTS™-equipped station are within communications range. This may be particularly use-ful during Search-and Rescue situations, where is important to stay in contact with othermembers of your group.Both stations must set up their DCS codes to the same code number, then activate theirARTS™ feature using the command appropriate for their radio. Alert ringers may be acti-vated, if desired.Whenever you push the PTT switch, or every 25 (or 15) secondsafter ARTS™ is activated, your radio will transmit a signal whichincludes a (subaudible) DCS signal for about 1 second. If the otherradio is in range, the beeper will sound (if enabled) and the displaywill show “IN.RNG” as opposed to the out of range display“OUT.RNG” in which ARTS™ operation begins.Whether you talk or not, the polling every 15 or 25 seconds willcontinue until you de-activate ARTS™. Every 10 minutes, moreover, you can have yourradio transmit your callsign via CW, so as to comply with identification requirements.When ARTS™ is de-activated, DCS will also be deactivated (if you were not using itpreviously in non-ARTS™ operation).If you move out of range for more than one minute (four pollings), your radio will sensethat no signal has been received, three beeps will sound, and the display will revert to“OUT.RNG.” If you move back into range, your radio will again beep, and the display willchange back to the “IN.RNG” indication.During ARTS™ operation, your operating frequency will continue to be displayed, but nochanges may be made to it or other settings; you must terminate ARTS™ in order to resumenormal operation. This is a safety feature designed to prevent accidental loss of contactdue to channel change, etc.Basic ARTS™ Setup and OperationThe ARTS™ feature allows two kinds of alert beeps (with the additional option of turningthem off), so as to alert you to the current status of ARTS™ operation. Depending on yourlocation and the potential annoyance associated with frequent beeps, you may choose theBeep mode which best suits your needs before starting the ARTS™ operation.INRANG: The beeps are issued only when the radio first confirms that you are withinrange, but does not re-confirm with beeps thereafter.ALWAYS: Every time a polling transmission is received from the other station, the alertbeeps will be heard.OFF: No alert beeps will be heard; you must look at the display to confirm currentARTS™ status.ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
VX-127 OPERATING MANUAL 53To activate the ARTS™ feature:1. Set your radio and the other radio(s) to the same DCS code number, per the discussionon page 24.2. Press the [SET( )EMG] key momentarily to enter the Set mode.3. Rotate the DIAL knob to select Set Mode Item 2: ARTS.4. Press the [F] key momentarily to enable adjustment of this SetMode Item.5. Rotate the DIAL knob to select the desired ARTS™ Beep mode(see above).6. Press the [F] key mamentarily. You will observe the “OUT. RNG”display on the LCD below the operating frequency. ARTS™operation has now commenced.7. Every 25 seconds, your radio will transmit a “polling” call to theother station. When that station responds with its own ARTS™polling signal, the display will change to “IN.RNG” to confirmthat the other station’s polling code was received in response toyours.8. Press the [F] key momentarily to exit ARTS™ operation and resume normal function-ing of the transceiver.ARTS™ constitutes a form of “remote control” operation that may be re-stricted to certain frequencies. U.S. users should confirm the current statusof §97.201(b) of the FCC’s rules governing the 430 MHz band of the Ama-teur service before utilizing this feature.ARTS™ Polling Time OptionsThe ARTS™ feature may be programmed to poll every 25 seconds (default value) or 15seconds. The default value provides maximum battery conservation, because the pollingsignal is sent out less frequently. To change the polling interval:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 3: AR INT.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired polling interval (15or 25 seconds).5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
VX-127 OPERATING MANUAL54CW Identifier SetupThe ARTS™ feature includes a CW identifier, as discussed previously. Every ten minutesduring ARTS™ operation, the radio can be instructed to send “DE (your callsign) K” ifthis feature is enabled. The callsign field may contain up to 6 characters.Here’s how to program the CW Identifier:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 11: CW WRT.3. Press the [F] key momentarily to display any previously-storedcallsign.4. Press the [F] key again to clear any previous callsign.5. Rotate the DIAL knob to select the first letter/number of yourcallsign, then press the [F] key momentarily to save the firstletter/number and move on to the next character.6. Repeat the previous step, as many times as necessary, to com-plete your callsign. If you make a mistake, press the [(MHz)]key to move back to the previous letter/number’s slot, then re-select the correct letter/number.7. When you have finished entering your entire callsign and it con-tains less than 6 characters, press and hold in the [F] key for onesecond to confirm the callsign. (if you callsign has exactly 6 characters, you do notneed to press and hold in [F] in this step).8. Press the PTT switch to save the settings and exit to normal operation.9. Press the [SET( )EMG] key momentarily to enter the Set mode again.10. Rotate the DIAL knob to select Set Mode Item 10: CWID.11. Press the [F] key momentarily, then rotate the DIAL knob to setthis Item to “TX ON” (to enable the CW ID function).12. Press the PTT switch to save the settings and exit to normaloperation.You may check your work by monitoring the enteredcallsign. To do this, repeat steps 1- 7 above, then pressthe MONI switch.ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
VX-127 OPERATING MANUAL 55DTMF OPERATIONThe VX-127 is provided the Nine DTMF Autodial memories which allowing you to storetelephone numbers for autopatch use. You can also store short autopatch or Internet-linkaccess code streams so as to avoid having to send them manually.Here is the DTMF Autodial storage procedure:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 17: DT WRT.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the DTMF Memory register (“d1”~ “d9”) into which you wish to store this DTMF string.5. Press the [F] key momentarily to begin DTMF Memory entryinto the selected register.6. Rotate the DIAL knob to select the first digit of the DTMF string.Selectable entries are 0 - 9, and A - F, with E and F representingDTMF “” and “#” tones respectively.7. Press the [F] key to accept the first digit and move to the next digit of the DTMF string.8. Repeat steps 6 and 7 until you have completed the telephonenumber.9. If you make a mistake, press the [(MHz)] key to move back tothe previous digit, then re-select the correct number.10. Press and hold in the [F] key for one second to save the setting.11. If you store other numbers, repeat steps 4- 10 above, using adifferent DTMF memory register.12. When all required DTMF memories are filled to your satisfaction, press the PTTswitch to save the settings and exit to normal operationTo send the Telephone Number, Hold the PTT switch to continue transmitting duringfollowing steps:1. Press the [(MHz)] or [(MHz)] key to select the DTMF Memory register (“d1” ~“d9”) you wish send.2. Press the [LOW(LOCK)SET]  key momentarily to transmit the tone string. Once thestring begins, you may release the PTT switch, as the transmitter will be held “on theair” until the DTMF string is completed.You can change the DTMF Autodialer sending speed, using Set Mode Item 16: DT  SPD.See page 73 for details.You can also set a longer delay between the time you press the numerical key (correspond-ing to the DTMF memory string; with PTT switch pressed) and the instant when the firstDTMF digit is sent, using Set Mode Item 15: DT  DLY. See page 75 for details.
VX-127 OPERATING MANUAL56NOTE
VX-127 OPERATING MANUAL 57The VX-127 allows you to utilize a DTMF (Dual-Tone, Multi-Frequency) tone encoder/decoder, with a dedicated microprocessor providing paging and selective calling featuresnow that you've installed the optional FTD-7 DTMF Paging Unit. This capability allowsyou to make a call to a specific station (Paging), and to receive calls of your choice di-rected only to you (Code Squelch).The paging and code squelch systems use 3-digit numeric codes (000 - 999) which arestored in the DTMF Pager Memories. Basically, your receiver remains silent until it re-ceives the 3-digit DTMF pager code that matches those stored in the DTMF Pager Memory.The squelch then opens so the caller is heard, and the LCD displays the 3-digit DTMFpager code which was received. Also, the paging ringer immediately sounds, if the Bellfunction is activated. When you close the PTT switch to transmit, the 3-digit DTMF pagercode which is stored in the last selected DTMF Pager Memory register will be transmittedautomatically.On the paged radio, the squelch will close automatically five seconds after the incomingpage ends (you may now resume DTMF Pager operation).Storing the 3-digit code for the DTMF Pager Operation1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 56: PAG.COD.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the DTMF Pager Memory regis-ter into which you wish to store the access code.5. Press the [F] key momentarily. The first digit will blink.6. Rotate the DIAL knob to select the first digit of the 3-digit DTMFpager code. The “A” and “D” keys are “wild cards.”7. Press the [F] key momentarily to accept the first digit and moveto the second digit of the 3-digit DTMF pager code.8. Repeat the previous steps until you have completed the 3-digitDTMF pager code.9. Press the [REV(HOME)] key to toggle the decoder “on” and“off.” When the decoder is set to “off,” the “--” notation appearsbetween the DTMF pager memory register number and the 3-digit DTMF pager code; for example, “P2- -123.”The 3-digit DTMF pager code which does not have the “--” notation is used for en-code only.10. Press the PTT switch to save the new settings and exit to normal operation.DTMF PAGER OPERATION (REQUIRES OPTIONAL FTD-7)
VX-127 OPERATING MANUAL58Activating the DTMF Pager1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 55: PAGER.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select “ON.”5. Press the PTT switch to save the new setting and activate theDTMF Pager.When the DTMF Pager is activated, the “P” notation will re-place the “100 MHz” digit of the frequency display.6. Press the PTT switch to send the 3-digit DTMF pager code whichis stored in the last-selected DTMF Pager Memory register.7. When you receive a DTMF paging call, it will open your radio’sDTMF squelch, and the LCD will display the 3-digit DTMFpager code which was received. After five seconds, the DTMFpager will revert to its squelched mode.8. To disable the DTMF Pager, just repeat the above procedure, rotating the DIAL knobto select “OFF” in step 4 above.During DTMF Pager operation, you may set up the VX-127 such that a ringing “Bell”sound alerts you to the fact that a call is coming in, as described previously. See page 27 ofthe Operating Manual for details.DTMF PAGER OPERATION (REQUIRES OPTIONAL FTD-7)
VX-127 OPERATING MANUAL 59DTMF PAGER OPERATION (REQUIRES OPTIONAL FTD-7)When you activate the ANI (Automatic Number Identification) feature during DTMF Pageroperation, the DTMF tones stored in ANI memory will automatically be sent wheneveryou press the PTT switch. When the ANI is received, the LCD will displays the receivedANI code after the 3-digit DTMF pager code.Storing the ANI code1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 54: ANI.WRT.3. Press the [F] key momentarily to display any previously-stored ANI code.4. Press the [F] key again to clear any previous ANI code.5. Rotate the DIAL knob to select the first number/letter (0-9, A, B, C, D, E (substitutefor “”), and F (substitute for “#”), then press the [F] key momentarily to save thefirst letter/number and move on to the next character.6. Repeat the previous step, as many times as necessary (up to 16 characters), to com-plete ANI code. If you make a mistake, press the [(MHz)] key to move back to theprevious letter/number’s slot, then re-select the correct letter/number.7. When you have finished entering the ANI code and it contains less than 16 characters,press and hold in the [F] key for one second to confirm the callsign. (if the ANI codehas exactly 16 characters, you do not need to press and hold in [F] in this step).8. Press the PTT switch to save the settings and exit to normal operation.You may check your work by monitoring the entered callsign. To do this,repeat steps 1- 7 above, then press the MONI switch.Activating the ANI feature1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 53: ANI.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select “ON.”5. Press the PTT switch to save the new setting and activate theANI feature.6. Press the PTT switch to send the DTMF tones stored in ANI memory after the 3-digitDTMF pager code which is stored in the last-selected DTMFPager Memory register.7. When you receive a ANI code, the LCD will displays the re-ceived ANI code after the 3-digit DTMF pager code. You mayscroll the received ANI code by rotating the DIAL knob.8. To disable the ANI feature, just repeat the above procedure, ro-tating the DIAL knob to select “OFF” in step 4 above.ANI CODEFLAGPAGER CODE
VX-127 OPERATING MANUAL60PASSWORDThe VX-127 provides a security password feature which can minimize the chance thatyour transceiver could be used by an unauthorized party.When the password feature is activated, the radio will ask for the four digit password to beentered when the radio is first turned on. You must enter the fourdigit password from the keypad. If the wrong password is entered,the microprocessor will shut down the radio automatically.To enter the password , use the following procedure:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 31: PSWD W.3. Press the [F] key momentarily to display any previously-storedpassword.4. Press the [F] key again to clear any previous password.5. Rotate the DIAL knob to select the first digit of the desired letterwhich corresponding with the front panel keypad (S(substitutefor [SET( )EMG] key), L (substitute for [LOW(LOCK)] key) ,R (substitute for [REV(HOME)] key), U (substitute for[(MHz)] key), F (substitute for [F] key), M (substitute for[MR(SKIP)] key), V (substitute for [VFO(PRI)] key), and , D(substitute for [(MHz)] key).6. Press the [F] key to move to the next digit.7. Repeat steps 5 and 6 to program the remaining letters of thedesired password.8. If you make a mistake, press the [(MHz)] key to move back to the previous digit,then re-select the correct number/letter.9. When you have finished entering the password, press the PTT switch to save the newsetting and exit to normal operation.We recommend that you to write down the password number, and keep it in asafe place you can easily find if you forget your password.MISCELLANEOUS SETTINGS
VX-127 OPERATING MANUAL 61To Activate the Password feature:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 30: PSWD.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to set this Set Mode Item to “PWD. ON.”5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.6. If you wish to disable the Password feature, just repeat the aboveprocedure, rotating the DIAL knob to select “PWD.OFF” in step 4 above.If you forget the password number, you may turn on the transceiver by per-forming the “All Reset” procedure (see page 65). However, the VX-127 willclear the password, as well as all memories, and will restore all other settingsto factory defaults.CHANGING THE CHANNEL STEPSThe VX-127’s synthesizer provides the option of utilizing channel steps of 5/10/12.5/15/20/25/50/100 kHz per step, as well as an automatic step selection based on the currentoperating frequency (“AUTO”), any number of which may be important to your operatingrequirements. The VX-127 is set up at the factory in the “AUTO” configuration, whichprobably is satisfactory for most operation. However, if you need to change the channelstep increments, the procedure to do so is very easy.1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 45: STEP.3. Press the [F] key momentarily to enable adjustment of this Item.4. Rotate the DIAL knob to select the new channel step size.5. When you have made your selection, press the PTT switch tosave the new setting and return to normal operation.MISCELLANEOUS SETTINGSPASSWORD
VX-127 OPERATING MANUAL62MISCELLANEOUS SETTINGSRECEIVE BATTERY SAVER SETUPAn important feature of the VX-127 is its Receive Battery Saver, which “puts the radio tosleep” for a time interval, periodically “waking it up” to check for activity. If somebody istalking on the channel, the VX-127 will remain in the “active” mode, then resume its“sleep” cycles. This feature significantly reduces quiescent battery drain, and you maychange the amount of “sleep” time between activity checks using the Set Mode:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 37: RXSAVE.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired “sleep” duration. Theselections available are 200 ms, 300 ms, 500 ms, 1 second, 2seconds, or OFF. The default value is 200 ms.5. When you have made your selection, press the PTT switch to save the new setting andexit to normal operation.When you are operating on Packet, switch the Receive Battery Saver OFF, asthe sleep cycle may “collide” with the beginning of an incoming Packet trans-mission, causing your TNC not to receive the full data burst.TX BATTERY SAVERThe VX-127 also includes a useful Transmit Battery Saver, which will automatically lowerthe power output level when the last signal received was very strong. For example, whenyou are in the immediate vicinity of a repeater station, there generally is no reason to usethe High Power output in order to achieve full-quieting access to the repeater. With theTransmit Battery Saver, the automatic selection of Low Power operation conserves batterydrain significantly.To activate the Transmit Battery Saver:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 49: TXSAVE.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “SAV. ON”(thus activating the Transmit Battery Saver).5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.
VX-127 OPERATING MANUAL 63DISABLING THE TX/BUSY INDICATORFurther battery conservation may be accomplished by disabling the TX indicator whiletransmitting and disabling the BUSY indicator while receiving a signal. Use the followingprocedure:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 8: BSY.LED ifyou wish to disable the BUSY indicator or Set Mode Item 48:TX.LED if you wish to disable the TX indicator.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “LED.OFF”(thus disabling the BUSY or TX lamp).5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.6. If you wish to re-enable the TX/BUSY Indicator, just repeat theabove procedure, rotating the DIAL knob to select “LED. ON” in step 4 above.AUTOMATIC POWER-OFF (APO) FEATUREThe APO feature helps conserve battery life by automatically turning the radio off after auser-defined period of time within which there has been no dial or key activity. The avail-able selections for the time before power-off are 0.5 to 12.0 hours in 0.5 hour multiple, aswell as APO Off. The default condition for the APO is OFF, and here is the procedure foractivating it:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 1: APO.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired time period afterwhich the radio will automatically shut down.5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.When the APO is activated, the “ ” icon will appear on the LCD. Ifthere is no action by you within the time interval programmed, themicroprocessor will shut down the radio automatically.Rotate the VOL/PWR knob counter-clockwise to the “off” position, then clockwise out ofthe click-stop, to turn the radio on after an APO shutdown.MISCELLANEOUS SETTINGS
VX-127 OPERATING MANUAL64TRANSMITTER TIME-OUT TIMER (TOT)The TOT feature provides a safety switch which limits transmission time to a pre-pro-grammed value. This will promote battery conservation by not allowing you to make ex-cessively-long transmissions, and in the event of a stuck PTT switch (perhaps if the radioor a Speaker/Mic is wedged between car seats) it can prevent interference to other users aswell as battery depletion. As configured at the factory the TOT feature is set to “6 min-utes,” and here is the procedure for activating it:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 47: TOT.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set the Time-Out Timer to the desired“Maximum TX” time (between 1 and 30 minutes), or OFF.5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.1) When your transmission time is within 10 seconds of the Time-Out Timerexpiration, an Alert bell will provide an audible warning from the speaker.2) Since brief transmissions are the mark of a good operator, try setting upyour radio’s TOT feature for a maximum transmission time of one minute. This willsignificantly improve battery life, too!BUSY CHANNEL LOCK-OUT (BCLO)The BCLO feature prevents the radio’s transmitter from being activated if a signal strongenough to break through the “noise” squelch is present. On a frequency where stationsusing different CTCSS or DCS codes may be active, BCLO prevents you from disruptingtheir communications accidentally (because your radio may be muted by its own ToneDecoder). The default setting for the BCLO is OFF, and here is how to change that setting:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 5: BCLO.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “BCL. ON”(thus activating the BCLO feature).5. When you have made your selection, press the PTT switch tosave the new setting and exit to normal operation.MISCELLANEOUS SETTINGS
VX-127 OPERATING MANUAL 65DCS CODE INVERSIONThe DCS system was first introduced in the commercial LMR (Land Mobile Radio) ser-vice, where it is now in widespread use. DCS is sometime referred to by its different pro-prietary names, such as DPL® (Digital Private Line®, a registered trademark of Motorola,Inc.).DCS uses a codeword consisting of a 23-bit frame, transmitted (subaudible) at a data rateof 134.4 bps (bit/sec). Occasionally, signal inversion can result in the complement of acode to be sent or received. This prevents the receiver’s squelch from opening with DCSenabled, as the decoded bit sequence would not match that selected for operation.Typical situations that might cause inversion to occur are:Connection of an external receiver preamplifier.Operating through a repeater.Connection of an external linear amplifier.Note that code inversion does not mean that any of the above listed equipment is defective!In certain amplifier configurations, the output signal (phase) is inverted from the input.Small signal or power amplifiers having an odd number (1, 3, 5, etc.) of amplificationstages may result in inversion of a transmitted or received DCS code.While under most circumstances this should not occur (amplifier designs and industrystandards take this into account), if you find that your receiver squelch does not open whenboth you and the other station are using a common DCS code, you or the other station (butnot both) can try the following:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 14: DCS.N/R.3. Press the [F] key momentarily, then rotate the DIAL knob toselect one of the following modes:T/RX N: Encoder, Normal; Decoder, NormalRX R: Encoder, Normal; Decoder, Reverse (Inverted)TX R: Encoder, Reverse (Inverted); Decoder, NormalT/RX R: Encoder, Reverse (Inverted); Decoder, Reverse (Inverted)4. When you have made your selection, press the PTT switch to save the new setting andexit to normal operation.5. Remember to restore the default setting to “T/RX N” (Encoder; Normal, Decoder;Normal) when done.MISCELLANEOUS SETTINGS
VX-127 OPERATING MANUAL66CHANGING THE TX DEVIATION LEVELIn many areas of the world, channel congestion has required that operating channels beclosely spaced. In such operating environments, it often is required that operators usereduced deviation levels, so as to reduce the potential for interference to users on adjacentchannels. The VX-127 includes a simple method of accomplishing this:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 51: WID.NAR.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to set this Set Mode Item to “NARROW.”In this configuration (HALF DEVIATION active), thetransmitter’s deviation will be approximately ±2.5 kHz, and thereceived audio output level will be increased, for easier listening on the narrow signal.5. When you have made your selection, press the PTT switch to save the new setting andexit to normal operation.The “normal” setting for the deviation (when this Menu Item is set to WIDE) is ±5 kHz.MISCELLANEOUS SETTINGS
VX-127 OPERATING MANUAL 67In the event of erratic operation of the transceiver, it is possible that data on the micropro-cessor may have become corrupted. While this is a highly unusual situation, the only pathto recovery may involve resetting of the microprocessor. Here’s how to do this:1. Turn the radio off.2. Press and hold in the MONI switch (just below the PTT switch) while turning theradio on.3. Rotate the DIAL knob to select one of the choices from the reset menu:F1 SETRST: Resets the Set (Menu) mode settings to their factory defaults.F2 MEMRST:Clears the Memory settings to factory defaults.F3 MB RST: Clears the Memory Bank Assignments.F4 ALLRST: Clears all memories and other settings to factory defaults.4. Press the [F] key momentarily to complete the reset procedure.The “F5” option is used for setting up the “Memory Only” mode, and “F6”is used for Cloning. See page 34 for details regarding the memory Only mode,and the next section regarding Cloning.RESET PROCEDURES
VX-127 OPERATING MANUAL68The VX-127 includes a convenient “Clone” feature, which allows the memory and con-figuration data from one transceiver to be transferred to another VX-127. This can beparticularly useful when configuring a number of transceivers for a public service opera-tion. Here is the procedure for Cloning one radio’s data to another:1. Turn both radios off.2. Connect the user-constructed cloning cable and two optional CT-91 Microphone Adapt-ers (one on each end) between the MIC/SP jacks of the two radios.3. Press and hold in the MONI switch (just below the PTT switch) while turning theradios on. Do this for both radios (the order of switch-on does not matter).4. Rotate the DIAL knob on each radio to select to “F6 CLONE,”then press the [F] key momentarily.5. The display will disappear for a moment, then the “CLONE”notation will appear on the displays of both radios when the Clonemode is successfully activated in this step.6. On the Destination radio, press the MONI switch (“- - RX - -”will appear on the LCD).7. Press and hold in the PTT switch on the Source radio; “- - TX - -”will appear on the Source radio, and the data from this radio willbe transferred to the other radio.8. If there is a problem during the cloning process, “ERROR” willbe displayed. Check your cable connections and battery voltage,and try again.9. If the data transfer is successful, “CLONE” will reappear on bothdisplays. Turn both radios off and disconnect the cloning cable.You can then turn the radios back on, and begin normal opera-tion.CLONING
VX-127 OPERATING MANUAL 69NOTE
VX-127 OPERATING MANUAL70The VX-127 Set Mode, already described in parts of many previous chapters, is easy toactivate and set. It may be used for configuration of a wide variety of transceiver param-eters, some of which have not been detailed previously. Use the following procedure toactivate the Set Mode:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select the Set Mode Item to be ad-justed.3. Press the [F] key momentarily to enable adjustment of the SetMode Item.4. Rotate the DIAL knob to adjust or select the parameter to bechanged on the Set Mode Item selected in above step.5. After completing your selection and adjustment, press the PTT switch momentarily tosave the new setting and exit to normal operation.Some Set Mode Items (like Set Mode Item 46: TN FRQ) require that the [F]key be pressed after setting of the parameter, and before exiting to normaloperation.SET (MENU) MODESET MODE ITEM1 [APO]2 [ARTS]3 [AR INT]4 [ARS]5 [BCLO]6 [BEEP]7 [BELL]8 [BSY.LED]9 [CLK.SFT]10 [CWID]11 [CW WRT]12 [DC VLT]13 [DCS.COD]14 [DCS.N/R]15 [DT DLY]16 [DT SPD]17 [DT WRT]18 [ECS.CDR]19 [ECS.CDT]20 [EDG.BEP]FUNCTIONSetting of the Automatic Power-Off feature.Selects the Beep option during ARTS operation.Selects the Polling Interval during ARTS operation.Enables/Disables the Automatic Repeater Shift function.Enables/Disables the Busy Channel Lock-Out feature.Enables/Disables the beeper.Selects the number of CTCSS/DCS Bell ringer repetitions.Enables/Disables the BUSY LED while the Squelch is open.Shifting of the CPU clock frequency.Enables/disables the CW identifier during ARTS operation.Programs and activates the CW Identifier.Indicates the DC Supply Voltage.Setting of the DCS code.Enables/Disables “Inverted” DCS code decoding.Setting of the DTMF Autodialer Delay Time.Setting of the DTMF Autodialer Sending Speed.Programming of the DTMF Autodialer.Setting the Receiver Pager Code for the Enhanced CTCSSPaging & Code Squelch. Setting the Transmitting Pager Code for the EnhancedCTCSS Paging & Code Squelch.Enables/Disables the Band-edge beeper while selecting thefrequency via the DIAL knob.AVAILABLE VALUES(DEFAULT: BOLD ITALIC)OFF / 0.5H - 12.0 HINRANG / ALWAYS / OFF25 SEC / 15 SECARS. ON / ARS.OFFBCL. ON / BCL.OFFKEY+SC / KEY / OFFOFF / 1T / 3T /5T / 8T / CONTLED. ON / LED.OFFSFT.OFF / SFT. ONTX OFF / TX ON------104 DCS codes (023)T/RX N, RX R,TX R, T/RX R50MS / 100MS / 250MS /450MS / 750MS / 1000MS50MS / 100MS--- (R05 47)(T05 47)BEP.OFF / BEP. ON
VX-127 OPERATING MANUAL 71SET (MENU) MODEFUNCTIONSelects the alarm(s) utilized when the Emergency function isengaged.Selects the Internet Link Connection mode.Selects the Access Number (DTMF digit) for WIRES™operation.Selects the memory register for an Access Number (DTMFcode) for non-WIRES™ Selects the LCD/Keypad Lamp mode.Selects the Control Locking lockout combination.Selects the MONI switch function.Toggles the display indication between “frequency” and thechannel’s “Alpha/Numeric Tag.”Stores Alpha-Numeric “Tags” for the Memory channels.Enables/disables the Password feature.Stores the password.Selects the Scan Resume mode.Selects the function of the [HM/RV] key.Adjusts the RF Squelch threshold level.Sets the Repeater Shift Direction.Enables/disables the Priority Revert feature.Selects the Receive-mode Battery Saver interval (“sleep” ratio)Selects the Smart Search Sweep mode.Selects the Memory Scan channel-selection mode.Enables/Disables the Scan lamp while paused.Sets the magnitude of the repeater Shift.Selects the Memory Scan “Skip” channel-selection mode.Enables/Disables split CTCSS/DCS coding.Selects the Tone Encoder and/or Decoder mode.Setting of the synthesizer steps.Setting of the CTCSS Tone Frequency.Setting of the TOT time.Enables/Disables the TX LED while the radio is transmitting.Enables/Disables the Transmitter Battery Saver.Enables or disables “VFO Split” operation.Select Wide (±5 kHz) or Narrow (±2.5 kHz) TX Deviation.Enables/Disables the Emergency Automatic ID (EAI) Feature.AVAILABLE VALUES(DEFAULT: BOLD ITALIC)EMG.BEP / EMG.LMP /EMG.B+L / EMG.CWT /EMG.C+B / EMG.C+L /EMG.ALL / OFFINT.OFF / INT.COD / INT.MEMCODE 0 - CODE 9,CODE A - CODE F (CODE 1)d1 - d9KEY / CONT / OFFLK KEY / LKDIAL / LK K+D /LK PTT / LK P+K /LK P+D / LK ALLMONI / T-CALLFREQ / ALPHA---PWD.OFF / PWD. ON---BUSY / HOLD / TIME<REV> / <HOME>S-1 / S-2 / S-3 / S-4 / S-5 /S-6 / S-8 / S-FULL / OFFRPT.OFF / RPT.– / RPT. +RVT.OFF / RVT. ON200 MS / 300 MS /500 MS /1 SEC / 2 SSEC / OFFSINGLE / CONTONLY / MEMON / OFF0.00 - 99.95 MHz (0.60 MHz)OFF / SKIP / ONLYSPL.OFF / SPL. ONOFF / TONE / TSQL /REV TN / DCS / ECS5 / 10 / 12.5 / 15 / 20 / 25 / 50/ 100 kHz, or AUTO50 CTCSS tones (100 Hz)1MIN - 30MIN or OFF (6 MIN)LED. ON / LED.OFFSAV.OFF / SAV. ONVSP.OFF / VSP.ONWIDE / NARROWINT. 1M - INT.50M /COM. 1M-COM.50M / OFFSET MODE ITEM21 [EMG S]22 [I NET]23 [INT CD]24 [INT MR]25 [LAMP]26 [LOCK]27 [M/T-CL]28 [NAME]29 [NM WRT]30 [PSWD]31 [PSWD W]32 [RESUME]33 [REV/HM]34 [RF SQL]35 [RPT.MOD]36 [PRI.RVT]37 [RXSAVE]38 [S SRCH]39 [SCN MD]40 [SCN.LMP]41 [SHIFT]42 [SKIP]43 [SPLIT]44 [SQL.TYP]45 [STEP]46 [TN FRQ]47 [TOT]48 [TX.LED]49 [TXSAVE]50 [VFO.SPL]51 [WID.NAR]52 [EAI]SET MODE ITEM53 [ANI]54 [ANI.WRT]55 [PAGER]56 [PAG.COD]57 [PAG.ABK]FUNCTIONEnables/Disables the ANI function.Program the ANI Identifier.Enables/Disables the ANI function.Setting the Pager Code for the DTMF Pager.Enables/Disables the Answer Back function of the DTMF Pager.AVAILABLE VALUES(DEFAULT: BOLD ITALIC)ANI.OFF/ANI. ON---PAG.OFF/PAG. ON000 - 999ABK. OFF/ABK. ONThe following Set Mode Items will appears when the optional FTD-7 DTMF Paging Unit is installed.
VX-127 OPERATING MANUAL72SET (MENU) MODEREPEATER SETTINGEnables/Disables the Automatic Repeater Shift function.Sets the Repeater Shift Direction.Sets the magnitude of the repeater Shift.CTCSS/DSC/DTMF/EPCS SETTINGSelects the number of CTCSS/DCS Bell ringer repetitions.Setting of the DCS code.Enables/Disables “Inverted” DCS code decoding.Setting of the DTMF Autodialer Delay Time.Setting of the DTMF Autodialer Sending Speed.Programming of the DTMF Autodialer.Setting the Receiver Pager Code for the Enhanced CTCSSPaging & Code Squelch.Setting the Transmitting Pager Code for the EnhancedCTCSS Paging & Code Squelch.Enables/Disables split CTCSS/DCS coding.Selects the Tone Encoder and/or Decoder mode.Setting of the CTCSS Tone Frequency.ARTS SETTINGSelects the Beep option during ARTS operation.Selects the Polling Interval during ARTS operation.Enables/disables the CW identifier during ARTS operation.Programs and activates the CW Identifier (used during ARTSoperation).MEMORY SETTINGToggles the display indication between “frequency” and thechannel’s “Alpha/Numeric Tag.”Stores Alpha-Numeric “Tags” for the Memory channels.SCAN SETTINGSelects the Scan Resume mode.Enables/disables the Priority Revert feature.Selects the Memory Scan channel-selection mode.Enables/Disables the Scan lamp while paused.Selects the Memory Scan “Skip” channel-selection mode.POWER SAVER SETTINGSelects the Receive-mode Battery Saver interval (“sleep”ratio).Enables/Disables the Transmitter Battery Saver.WIRES™ SETTINGSelects the Internet Link Connection mode.Selects the Access Number (DTMF digit) for WIRES™ op-eration.Selects the memory register for an Access Number (DTMFdigit) for non-WIRES™.SET MODE ITEM4 [ARS]35 [RPT.MOD]41 [SHIFT]SET MODE ITEM7 [BELL]13 [DCS.COD]14 [DCS.N/R]15 [DT DLY]16 [DT SPD]17 [DT WRT]18 [ECS.CDR]19 [ECS.CDT]43 [SPLIT]44 [SQL.TYP]46 [TN FRQ]SET MODE ITEM2 [ARTS]3 [AR INT]10 [CWID]11 [CW WRT]SET MODE ITEM28 [NAME]29 [NM WRT]SET MODE ITEM32 [RESUME]36 [PRI.RVT]39 [SCN MD]40 [SCN.LMP]42 [SKIP]SET MODE ITEM37 [RXSAVE]49 [TXSAVE]SET MODE ITEM22 [I NET]23 [INT CD]24 [INT MR]AVAILABLE VALUES (DEFAULT)ARS. ON / ARS.OFFRPT.OFF / RPT. –  / RPT. + ()0.00 - 99.95 MHz ()AVAILABLE VALUES (DEFAULT)OFF / 1T / 3T / 5T / 8T / CONT104 standard DCS codes (023)T/RX N, RX R, TX R, T/RX R50MS / 100MS / 250MS / 450MS /750MS / 1000MS50MS /100MS–(R05_47)(T05_47)SPL.OFF / SPL. ONOFF / TONE / TSQL /REV TN / DCS50 standard CTCSS tones (100 Hz)AVAILABLE VALUES (DEFAULT)INRANG / ALWAYS / OFF25 SEC / 15 SECTX OFF / TX ON–AVAILABLE VALUES (DEFAULT)FREQ / ALPHA–AVAILABLE VALUES (DEFAULT)BUSY / HOLD / TIMERVT.OFF / RVT. ONONLY / MEMON / OFFOFF / SKIP / ONLYAVAILABLE VALUES (DEFAULT)200 MS / 300 MS / 500 MS /1 S / 2 S / OFFSAV.OFF / SAV. ONAVAILABLE VALUES (DEFAULT)INT.OFF / INT.COD / INT.MEMCODE 0 - CODE 9,CODE A - CODE F, (CODE 1)d1 - d9
VX-127 OPERATING MANUAL 73SET (MENU) MODESWITCH/KNOB SETTINGEnables/Disables the beeper.Selects the LCD/Keypad Lamp mode.Selects the Control Locking lockout combination.Selects the MONI switch function.Selects the function of the [HM/RV] key.MISCELLANEOUS SETTINGSetting of the Automatic Power-Off feature.Enables/Disables the Busy Channel Lock-Out feature.Enables/Disables the BUSY LED while the Squelch is open.Shifting of the CPU clock frequency.Indicates the DC Supply Voltage.Enables/Disables the Band-edge beeper while selecting thefrequency via the DIAL knob.Selects the alarm(s) utilized when the Emergency functionis engaged.Enables/disables the Password feature.Stores the password.Adjusts the RF Squelch threshold level.Selects the Smart Search Sweep mode.Setting of the synthesizer steps.Setting of the TOT timeEnables/Disables the TX LED while the radio is transmit-ting.Enables or disables “VFO Split” operation.Select Wide (±5 kHz) or Narrow (±2.5 kHz) TX Deviation.Enables/Disables the Emergency Automatic ID (EAI) Fea-ture.PAGER SETTING (REQUIRES OPTIONAL FTD-7)Enables/Disables the ANI function.Program the ANI Identifier.Enables/Disables the ANI function.Setting the Pager Code for the DTMF Pager.Enables/Disables the Answer Back function of the DTMFPager.SET MODE ITEM6 [BEEP]25 [LAMP]26 [LOCK]27 [M/T-CL]33 [REV/HM]SET MODE ITEM1 [APO]5 [BCLO]8 [BSY.LED]9 [CLK.SFT]12 [DC VLT]20 [EDG.BEP]21 [EMG S]30 [PSWD]31 [PSWD W]34 [RF SQL]38 [S SRCH]45 [STEP]47 [TOT]48 [TX.LED]50 [VFO.SPL]51 [WID.NAR]52 [EAI]SET MODE ITEM53 [ANI]54 [ANI.WRT]55 [PAGER]56 [PAG.COD]57 [PAG.ABK]AVAILABLE VALUES (DEFAULT)KEY+SC / KEY / OFFKEY / 5SEC / TOGGLELK KEY / LKDIAL / LK K+D / LKPTT / LK P+K / LK P+D / LK ALLMONI / T-CALL<REV> / <HOME>AVAILABLE VALUES (DEFAULT)OFF / 0.5H - 12.0 HBCL. ON / BCL.OFFLED. ON / LED.OFFSFT.OFF / SFT. ON–BEP.OFF / BEP. ONEMG.BEP / EMG.LMP / EMG.B+L /EMG.CWT / EMG.C+B /EMG.C+L / EMG.ALL / OFFPWD.OFF / PWD. ON–S-1 / S-2 / S-3 / S-4 / S-5 / S-6 /S-8 / S-FULL / OFFSINGLE / CONT5 / 10 /12.5 / 15 / 20 / 25 /50 / 100 kHz, or AUTO1MIN - 30MIN or OFF (6MIN)LED. ON / LED.OFFSPL.OFF / SPL. ONWIDE / NARROWINT. 1M - INT.50M /COM. 1M-COM.50M / OFFAVAILABLE VALUES (DEFAULT)ANI.OFF / ANI. ON–PAG.OFF / PAG. ON000 - 999ABK. OFF / ABK. ON
VX-127 OPERATING MANUAL74Set Mode Item 1 [APO]Function: Setting of the Automatic Power-Off feature.Available Values: OFF/0.5H - 12.0 H in 0.5 hour multiplesDefault: OFFSet Mode Item 2 [ARTS]Function: Selects the Beep option during ARTS operation.Available Values: INRANG/ALWAYS/OFFDefault: INRANGINRANG: Beeps sound only when the radio first detects that you are within range.ALWAYS: Beeps sound every time a polling transmission is received from the other sta-tion (every 15 or 25 seconds when in range).OFF: No alert beeps sound.Set Mode Item 3 [AR INT]Function: Selects the Polling Interval during ARTS operation.Available Values: 25 SEC/15 SECDefault: 25SECSet Mode Item 4 [ARS]Function: Enables/Disables the Automatic Repeater Shift function.Available Values: ARS. ON/ARS.OFFDefault: ARS. ONSet Mode Item 5 [BCLO]Function: Enables/Disables the Busy Channel Lock-Out feature.Available Values: BCL. ON/BCL.OFFDefault: BCL.OFFSet Mode Item 6 [BEEP]Function: Enables/Disables the beeper.Available Values: KEY+SC/KEY/OFFDefault: KEY+SCKEY+SC: The beeper sounds when you press any key, or when the scanner stops.KEY: The beeper sounds when you press any key.OFF: Beeper is disabled.Set Mode Item 7 [BELL]Function: Selects the number of CTCSS/DCS Bell ringer repetitions.Available Values: OFF/1T/3T/5T/8T/CONT (Continuous ringing)Default: OFFSET (MENU) MODE
VX-127 OPERATING MANUAL 75Set Mode Item 8 [BSY.LED]Function: Enables/Disables the BUSY LED while the Squelch is open.Available Values: LED. ON/LED.OFFDefault: LED. ONSet Mode Item 9 [CLK.SFT]Function: Shifting of the CPU clock frequency.Available Values: SFT.OFF/SFT. ONDefault: SFT.OFFThis function is only used to move a spurious response “birdie,” should it fall on a desiredfrequency.Set Mode Item 10 [CWID]Function: Enables/disables the CW identifier during ARTS operation.Available Values: TX OFF/TX ONDefault: TX OFFSet Mode Item 11 [CW WRT]Function: Programs and activates the CW Identifier (used during ARTS operation).See page 54 for details.Set Mode Item 12 [DC VLT]Function: Indicates the DC Supply Voltage.Set Mode Item 13 [DCS.COD]Function: Setting of the DCS code.Available Values: 104 standard DCS codesDefault: DCS.023Set Mode Item 14 [DCS.N/R]Function: Enables/Disables “Inverted” DCScode decoding.Available Values: T/RX N, RX R, TX R,T/RX RDefault: T/RX NSet Mode Item 15 [DT DLY]Function: Setting of the DTMF Autodialer Delay Time.Available Values: 50MS/100MS/250MS/450MS750MS/1000MSDefault: 450MSSet Mode Item 16 [DT SPD]Function: Setting of the DTMF Autodialer Sending Speed.Available Values: 50MS (high speed)/100MS (low speed)Default: 50MSSET (MENU) MODEDCS CODE023 025 026 031 032 036 043 047 051 053054 065 071 072 073 074 114 115 116 122125 131 132 134 143 145 152 155 156 162165 172 174 205 212 223 225 226 243 244245 246 251 252 255 261 263 265 266 271274 306 311 315 325 331 332 343 346 351356 364 365 371 411 412 413 423 431 432445 446 452 454 455 462 464 465 466 503506 516 523 526 532 546 565 606 612 624627 631 632 654 662 664 703 712 723 731732 734 743 754 – – – – – –
VX-127 OPERATING MANUAL76Set Mode Item 17 [DT WRT]Function: Programming of the DTMF Autodialer.See page 55 for details.Set Mode Item 18 [ECS.CDR]Function: Setting the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch.See page 26 for details.Set Mode Item 19 [ECS.CDT]Function: Setting the Transmitting Pager Code for the Enhanced CTCSS Paging & CodeSquelch.See page 26 for details.Set Mode Item 20 [EDG.BEP]Function: Enables/Disables the Band-edge beeper while selecting the frequency via theDIAL knob.Available Values: BEP.OFF/ BEP. ONDefault: BEP.OFFSet Mode Item 21 [EMG S]Function: Selects the alarm(s) utilized when the Emergency function is engaged.Available Values: EMG.BEP/EMG.LMP/EMG.B+L/EMG.CWT/EMG.C+B/EMG.C+L/EMG.ALL/OFFDefault: EMG.B+LEMG.BEP: Loud “Alarm” sounds.EMG.LMP: The LCD/Keypad lamp flashes.EMG.B+L: Loud “Alarm” sounds and the LCD/Keypad lamp flashes.EMG.CWT: Transmits the Morse Code “SOS” (• • • – – – • • •) message on the air begin-ning one minute after activation of the Emergency function.EMG.C+B: Loud “Alarm” sounds and the Morse Code “SOS” (• • • – – – • • •) message istransmitted on the air beginning one minute after activation of the Emergencyfunction.EMG.C+L: The LCD/Keypad lamp flashes, and the Morse Code “SOS” (• • • – – – • • •)message is transmitted on the air beginning one minute after activation of theEmergency function.EMG.ALL: All of the above are activated.OFF: Disables the Emergency function. The Emergency function also cannot beengaged, by pressing and holding in the [WX(EMG) ] key, if this Menu isset to “OFF.”When the radio is set to the EMG.CWT, EMG.C+B, EMG.C+L, or EMG.ALL mode, theradio will be instructed to send “DE (your callsign)” after the sending of the SOS message,if your callsign is entered via Set Mode Item 10: CWID.SET (MENU) MODE
VX-127 OPERATING MANUAL 77Set Mode Item 22 [I NET]Function: Selects the Internet Link Connection mode.Available Values: INT.OFF/INT.COD/INT.MEMDefault: INT.OFFINT.OFF: Disables the Internet Link Connection mode.INT.COD: Sets up the Internet Link Connection mode for WIRES™ access.INT.MEM: Sets up the Internet Link Connection mode for other (DTMF string) InternetLink System access.Set Mode Item 23 [INT CD]Function: Selects the Access Number (DTMF digit) for WIRES™ operation.Available Values: CODE 0 - CODE 9, CODE A - CODE FDefault: CODE 1Set Mode Item 24 [INT MR]Function: Selects the memory register for an Access Number (DTMF code) for non-WIRES™ Internet Link System access.Available Values: d1 - d9Default: d1Set Mode Item 25 [LAMP]Function: Selects the LCD/Keypad Lamp mode.Available Values: KEY/CONT/OFFDefault: KEYKEY: Illuminates the Keypad/LCD lamp for five seconds when you rotate the DIALknob or press the keypad or any switch (except PTT switch). This is the factory-programmed default setting.CONT: Illuminates the Keypad/LCD lamp continuously.OFF: Disables the Keypad/LCD lamp.Set Mode Item 26 [LOCK]Function: Selects the Control Locking lockout combination.Available Values: LK KEY/LKDIAL/LK K+D/LK PTT/LK P+K/LK P+D/LK ALLDefault: LK K+DNote: “K” = “Key;” “D” = “Dial;” and “P” = “PTT.”SET (MENU) MODE
VX-127 OPERATING MANUAL78Set Mode Item 27 [M/T-CL]Function: Selects the MONI key (just below the PTT switch) function.Available Values: MONI/T-CALLDefault: Depends on the transceiver version.MONI: Pressing the MONI key causes the Noise/Tone Squelch to be over-ridden, allow-ing you to listen for weak (or non-encoded) signals.T-CALL: Pressing the MONI key activates a 1750-Hz burst tone, used for repeater accessin many countries (especially in Europe).Set Mode Item 28 [NAME]Function: Toggles the display indication between “frequency” and the channel’s “Alpha/Numeric Tag.”Available Values: FREQ/ALPHADefault: FREQSet Mode Item 29 [NM WRT]Function: Stores Alpha-Numeric “Tags” for the Memory channels.See page 31 for details.Set Mode Item 30 [PSWD]Function: Enables/disables the Password feature.Available Values: PWD.OFF/PWD. ONDefault: PWD.OFFSet Mode Item 31 [PSWD W]Function: Stores the password.Available entries are W, L, R, U, F, M, V, and DSet Mode Item 32 [RESUME]Function: Selects the Scan Resume mode.Available Values: BUSY/HOLD/TIMEDefault: BUSYBUSY: The scanner will hold until the signal disappears, then will resume when the car-rier drops.HOLD: The scanner will stop when a signal is received, and will not restart.TIME: The scanner will hold for the five seconds, then resume whether or not the otherstation is still transmitting.SET (MENU) MODE
VX-127 OPERATING MANUAL 79Set Mode Item 33 [REV/HM]Function: Selects the function of the [REV(HOME)] key.Available Values: <REV>/<HOME>Default: <REV><REV>: Pressing the [REV(HOME)] key reverses the transmit and receive frequenciesduring repeater operation.<HOME>: Pressing the [REV(HOME)] key instantly recalls a favorite “Home” channel.Set Mode Item 34 [RF SQL]Function: Adjusts the RF Squelch threshold level.Available Values: S-1/S-2/S-3/S-4/S-5/S-6/S-8/S-FULL/OFFDefault: OFFSet Mode Item 35 [RPT.MOD]Function: Sets the Repeater Shift Direction.Available Values: RPT.OFF/RPT. –/RPT. +Default: Depends on the transceiver version, as well as the setting of Set Mode Item 4:ARS.Set Mode Item 36 [PRI.RVT]Function: Enables/disables the Priority Revert feature.Available Values: RVT.OFF/RVT. ONDefault: RVT.OFFSee page 43 for details.Set Mode Item 37 [RXSAVE]Function: Selects the Receive-mode Battery Saver interval (“sleep” ratio)Available Values: 200 MS(1:1)/300 MS(1:1.5)/500 MS(1:2.5)/1 S(1:5)/2 S(1:10)/OFFDefault: 200 MSSet Mode Item 38 [S SRCH]Function: Selects the Smart Search Sweep mode.Available Values: SINGLE/CONTDefault: SINGLESINGLE: The transceiver sweeps the current band once in each direction, starting on thecurrent frequency. All channels where activity is present (up to 15 in each di-rection) are loaded into the Smart Search memories. Whether or not all 31memories are filled, the search stops after one sweep in each direction.CONT: The transceiver makes a sweep in each direction as with the “SINGLE” mode,but if all 31 channels are not filled after the first sweep, the radio continuessweeping until they are all filled.SET (MENU) MODE
VX-127 OPERATING MANUAL80Set Mode Item 39 [SCN MD]Function: Selects the Memory Scan channel-selection mode.Available Values: ONLY/MEMDefault: MEMONLY: The scanner will only scan channels that are flagged (Preferential Scan List).MEM: The scanner will “skip” the flagged channels during scanning.Set Mode Item 40 [SCN.LMP]Function: Enables/Disables the Scan lamp while paused.Available Values: ON/OFFDefault: ONSet Mode Item 41 [SHIFT]Function: Sets the magnitude of the repeater Shift.Available Values: 0.00 - 99.95 MHz (50 kHz increments)Default: Depends on the operating band and transceiver version.Set Mode Item 42 [SKIP]Function: Selects the Memory Scan “Skip” channel-selection mode.Available Values: OFF/SKIP/ONLYDefault: OFFSKIP: The scanner will “skip” the flagged channels during scanning.ONLY: The scanner will only scan channels that are flagged (Preferential Scan List).OFF: All memory channels will be scanned (the “flag” will be ignored).Set Mode Item 43 [SPLIT]Function: Enables/Disables split CTCSS/DCS coding.Available Values: SPL.OFF/SPL. ONDefault: SPL.OFFWhen this Set Mode Item is set to “SPL. ON,” you will see the following additional param-eters after the “DCS” parameter while configuring Set Mode Item 44: SQL.TYP.D: DCS Encode only.T DCS: Encodes a CTCSS tone and Decodes a DCS code.D TSQL: Encodes a DCS code and Decodes a CTCSS tone.Select the desired operating mode from the selections shown above.SET (MENU) MODE
VX-127 OPERATING MANUAL 81Set Mode Item 44 [SQL.TYP]Function: Selects the Tone Encoder and/or Decoder mode.Available Values: OFF/TONE/TSQL/REV TN/DCS/ECSDefault: OFFTONE: CTCSS EncoderTSQL: CTCSS Encoder/DecoderREV TN: Reverse CTCSS Decoder (Mutes receiver when matching tone is received)DCS: Digital Coded Encoder/DecoderECS: Enhanced Paging & & Code SquelchNote: See also Set Mode Item 43: SPLIT regarding additional selections available during“Split Tone” operation.Set Mode Item 45 [STEP]Function: Setting of the synthesizer steps.Available Values: 5/10/12.5/15/20/25/50/100 kHz, or AUTODefault: AUTO (Step automatically changes according to operating frequency.)Set Mode Item 46 [TN FRQ]Function: Setting of the CTCSS Tone Fre-quency.Available Values: 50 standard CTCSS tonesDefault: 100.0 HzSet Mode Item 47 [TOT]Function: Setting of the TOT timeAvailable Values: 1MIN - 30MIN or OFFDefault: 6MIN (minutes)The time-out timer shuts off the transmitter after continuous transmission of the programmedtime.Set Mode Item 48 [TX LED]Function: Enables/Disables the TX LED while the radio is transmitting.Available Values: LED. ON/LED.OFFDefault: LED. ONSet Mode Item 49 [TXSAVE]Function: Enables/Disables the Transmitter Battery Saver.Available Values: SAV.OFF/ SAV. ONDefault: SAV.OFFSet Mode Item 50 [VFO.SPL]Function: Enables or disables “VFO Split” operation.Available Values: VSP.OFF/VSP. ONDefault: VSP.OFFSET (MENU) MODECTCSS TONE FREQUENCY (Hz)  67.0   69.3   71.9   74.4   77.0   79.7  82.5   85.4   88.5   91.5   94.8   97.4100.0 103.5 107.2 110.9 114.8 118.8123.0 127.3 131.8 136.5 141.3 146.2151.4 156.7 159.8 162.2 165.5 167.9171.3 173.8 177.3 179.9 183.5 186.2189.9 192.8 196.6 199.5 203.5 206.5210.7 218.1 225.7 229.1 233.6 241.8250.3 254.1 – – – –
VX-127 OPERATING MANUAL82Set Mode Item 51 [WID.NAR]Function: Select Wide (±5 kHz) or Narrow (±2.5 kHz) TX Deviation.Available Values: WIDE/NARROWDefault: WIDENote: If “Narrow” is selected, the receiver audio level is increased slightly to compensatefor the reduced deviation. The receiver IF filter bandwidth is not changed via this setting.Set Mode Item 52 [EAI]Function: Enables/Disables the Emergency Automatic ID (EAI) Feature.Available Values:INT. 1M - INT.10M, INT.15M, INT.20M, INT.30M, INT.40M, INT. 50M,CON. 1M - CON.10M, CON.15M, CON.20M, CON.30M, CON.40M, CON. 50M, and OFFDefault: OFFThe following Set Mode Items will appears when the optional FTD-7 DTMF PagingUnit is installed.Set Mode Item 53 [ANI]Function: Enables/Disables the ANI function.Available Values: ANI.OFF/ANI. ONDefault: ANI. OFFSet Mode Item 54 [ANI.WRT]Function: Program the ANI Identifier.See page 59 for details.Set Mode Item 55 [PAGER]Function: Enables/Disables the ANI function.Available Values: PAG.OFF/PAG. ONDefault: PAG. OFFSet Mode Item 56 [PAG.COD]Function: Setting the Pager Code for the DTMF Pager.See page 57 for details.Set Mode Item 57 [PAG.ABK]Function: Enables/Disables the Answer Back function of the DTMF Pager.Available Values: ABK.OFF/ABK. ONDefault: ABK. OFFSET (MENU) MODE
VX-127 OPERATING MANUAL 83GeneralFrequency Ranges: RX 430 - 440 MHz or 420 - 470 MHzTX 430 - 440 MHz or 430 - 450 MHzChannel Steps: 5/10/12.5/15/20/25/50/100 kHzFrequency Stability: ±5 ppm @ 14 °F to +140 °F (–10 °C to +60 °C)Repeater Shift: ±5 MHz, ±7.2 MHz, or ±1.6 MHzEmission Type: F2D, F3EAntenna Impedance: 50 ΩSupply Voltage: Nominal: 7.2 V DC(Negative Ground) Operating: 6.0 ~ 16.0 V DC (EXT DC Jack)11.0 ~ 16.0 V DC (EXT DC Jack with Charging)Current Consumption: 130 mA (Receive, 200 mW output)(Approx. @7.2 V) 50 mA (Standby, Saver Off)22 mA (Standby, Saver On)8 mA (Auto Power Off)1.8 A (5 W TX)Operating Temperature: –4 °F to +140 °F (–20 °C to +60 °C)Case Size: 2.36” (W) x 4.72” (H) x 1.26” (D) (60 x 120 x 32 mm)w/o knob, antenna, & belt clipWeight: 13.8 Oz (390 g) with FNB-83, antenna, and belt clipTransmitterRF Power Output: 5.0 W (High) / 2.0 W (Middle) / 0.5 W (Low)  (@7.2 V)Modulation Type: Variable Reactance F2D, F3EMaximum Deviation: ±5.0 kHz (F2D, F3E)Spurious Emission: At least 60 dB down (@ High and Middle power)At least 40 dB down (@ Low power)Microphone Impedance:2 kΩReceiverCircuit Type: Double-Conversion SuperheterodyneIntermediate Frequencies: 1st: 47.25 MHz2nd: 450 kHzSensitivity: 0.2 µV for 12 dB SINADSelectivity: 12 kHz/35 kHz (–6 dB /–60 dB)AF Output: 700 mW @ 16 Ω for 10 % THD (Internal Speaker)(@ 7.5 V) 400 mW @ 8 Ω for 10 % THD (EXT SP Jack)Specifications are subject to change without notice, and are guaranteed within the 430MHz amateur band only. Frequency ranges and functions will vary according to trans-ceiver version; check with your dealer.SPECIFICATIONS
VX-127 OPERATING MANUAL84INSTALLATION OF THE FTD-7 DTMF PAGING UNIT (OPTION)Peel off theCaution SealPress theOptional UnitAffix the suppliedCaution SealConnector1. Make sure that the transceiver is off. Remove the hard or soft case, if used.2. Remove the battery pack.3. Locate the connector for the FTD-7 under the caution seal in the battery compartmenton the back of the radio; just peel off the caution seal.4. Align the connector on the FTD-7 with the transceiver's connector, and gently pressthe unit into place.5. Affix the new (supplied) caution seal, and replace the battery.6. Installation is now complete.When the optional FTD-7 DTMF Pager Unit is installed, a “PGU”notation will be indicated on the display for 2 seconds, along withthe current DC supply voltage, when you turn the radio on.
1. Changes or modifications to this device not expressly approved by VERTEXSTANDARD could void the user’s authorization to operate this device.2. This device complies with part 15 of the FCC Rules. Operation is subject tothe following two conditions: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference includingreceived, interference that may cause undesired operation.3. The scanning receiver in this equipment is incapable of tuning, or readilybeing altered, by the User to operate within the frequency bands allocatedto the Domestic public Cellular Telecommunications Service in Part 22.WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULARRADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULESAND FEDERAL LAW.DECLARATION BY MANUFACTURERThe Scanner receiver is not a digital scanner and is incapable of being convertedor modified to a digital scanner receiver by any user.
Copyright 2005VERTEX STANDARD CO., LTD.All rights reserved.No portion of this manualmay be reproducedwithout the permission ofVERTEX STANDARD CO., LTD. 0511X-0KEH022U200

Navigation menu