    WT530 Programmable Thermostat Heat/Cool/Off Instruction Manual 24Vac (915MHz)              170803                          Before Installation   Turn off WT530R Receiver, all electronic source and electrical devices which will be connected before installation and maintenance.   The installer must be a trained service personnel.  Installation Location The WT530T thermostat should be mounted on an inner wall ~5 feet above the floor in a position where it is readily affected by changes of the general room temperature with freely circulating air.    Prevent direct exposure to sunlight, drip or splash. Do not place the unit at a location where air circulation is low, or where there are great temperature changes (e.g. near door). Do not place the thermostat near heat generating sources (e.g. radiators, hot air vents, TV or lights).  WT530T transmitter Installation  Opening Pull out the battery drawer. Then lightly press on the spot shown below in order to detach the front shell from the base.  Mounting 1. Ensure that the surface is level. 2. Place the cables at the hole near the terminal block. 3. Insert 2 pcs of wall anchors into the holes           of the wall. 4. Fasten the thermostat with 2 pcs of long screws through the 2 mounting holes.    Communication address Set communication address for   Communication Setup you   wish to use.  Batteries Insertion Pull out the battery drawer   and insert 2 fresh AAA alkaline   batteries into the drawer   according to the polarity   marked inside, then slide the   drawer back into place.  Dimension in mm(Transmitter)             WT530R receiver Installation  Using the accessory screws and wall anchors provided, mount the receiver with the key-hole at the back.   Open the front door and remove the battery compartment that hide the second screw hole. (This unit does not use battery; the battery compartment is a dummy to cover the screw hole.)            Wiring  There are 5 terminals. R and C connect to 24V power supply.   Terminal W is for heating , terminal Y is for cooling and terminal G is for fan.        WT530T Operation  When the unit is powered on, all the LCD segments are ON and then the first display screen is Normal Display Mode as below picture.             Button  Description MODE For changing the system mode: OFF: system off HEAT: heating only on COOL: cooling only on. SET For changing the Setting Menu.  (Fan, Time, Program) UP & DOWN To adjust temperature setpoint (temporary override)   LCD  Description DEFROST In heat mode, when temperature is below 5°C / 40°F, Heater is on regardless of the setting temperature. LO Below 0°C / 32°F, heating will be activated in Heat Mode. HI Above 40°C/ 99°F. cooling will be activated in Cool Mode. - - Sensor is shortened or not connected.   Communication Setup 1. Power on WT530R receiver, all LED light up then turn off. 2. Select the communication address at the WT530T transmitter. 3. Power on the WT530T transmitter (thermostat). 4. Press and hold the setup key on the receiver for 1 second, then the setup LED will be flashing.   5. Press and hold MODE and SET buttons on the thermostat, enter to the initial pairing mode (“PA” shown on screen for 5 second). 6. If the pairing is completed, the receiver setup LED will turn on.  In case the RF receiver is interfered by other wireless products, power OFF the receiver and change  to other  address.  Redo the above steps  with another address to reestablish a communication with the receiver.    Time Setting 1. Press SET button to enter Setting Menu. 2. Press UP or DOWN button to display CLOC and press SET button. 3. Press NEXT button to select the item that you want to change (Day of week, Hour or Minute). 4. Press UP or DOWN button to adjust the item. 5. Press MODE button to confirm the setting and return to Setting Menu. 6. *** Press MODE button to return to Normal Display Mode.   Temperature Control This product can work as a simple setback thermostat or a programmable thermostat. By default, this product is configured as a simple setback thermostat (Program Off).  Program On When program is on, this thermostat will control the output according to the programmed time and temperature.   The Default Program Settings are as below:    Heat Mode: Time Zone MON~FRI  SAT  SUN Time °F/°C Time °F/°C Time °F/°C WAKE  6AM 70/21.0 8AM 70/21.0 8AM 70/21.0 OUT  8AM 61/16.0 10AM 61/16.0 10AM 61/16.0 BACK  6PM  70/21.0 6PM  70/21.0 6PM  70/21.0 SLEEP  10PM 61/16.0 11PM 61/16.0 11PM 61/16.0  UP Button DOWN Button MODE   Button  SET    Button Room Temperature Time Upper position: 1 Lower position: 0
Cool Mode: Time Zone MON~FRI  SAT  SUN Time °F/°C  Time °F/°C  Time °F/°C WAKE 6AM 75/24.0 8AM 75/24.0 8AM 75/24.0 OUT 8AM 85/29.5 10AM 85/29.5 10AM 85/29.5 BACK 6PM 75/24.0 6PM 75/24.0 6PM 75/24.0 SLEEP 10PM 85/29.5 11PM 85/29.5 11PM 85/29.5  Program Setting The above program time and temperature can be modified.    To adjust Heat/Cool program settings: 1. In Heat/Cool Mode, press SET button to enter Setting Menu. 2. Press UP or DOWN button to display PROG.   3. Press SET button to enter program setting: “ON”/”OFF”. 4. Press UP or DOWN button to select program on / program off. 5. Make sure “On” is selected, press SET button to select the item that you want to change (Weekday/Weekend, Four Zones, Hour, Minute or Setting Temperature). 6. Press UP or DOWN button to adjust the item. 7. Press MODE button to return to Weekday/Weekend program 8. Press MODE button again, to confirm the setting and return to Setting Menu. 9. *** Press MODE button to return to Normal Display Mode.    Temporary Override When Program is On, this thermostat controls the output according to the program.   If you want to override the programmed temperature temporarily: 1. Press UP or DOWN button to adjust Heat / Cool setting temperature setpoint with    displayed. 2. In Heat Mode, only Heat setting temperature can be adjusted. 3. In Cool Mode, only Cool setting temperature can be adjusted. 4. The Heat / Cool setting temperature will be confirmed and the thermostat will return to Normal Display Mode, if no key is pressed for 10 sec. Temporary Override Mode will last until the next programmed time (zone) begins. At that time, the Heat / Cool setting temperature will follow the programmed setting temperature and    will disappear. Or   can be stopped manually by pressing MODE key.  Program Off  (default) When Program is Off, this thermostat controls the output according to a single setpoint like a simple setback thermostat. To set the unit to be Program Off, follow the above “Program Setting” to select Program Off. When this thermostat is Program Off, the Program Mode will be disabled and the time zone icons will disappear in Normal Display Mode. To adjust the setpoint at Program Off: 1. Press UP or DOWN button to adjust the Heat / Cool setting temperature. The icon    will NOT be shown in Program Off. 2. In Heat Mode, only Heat setting temperature can be adjusted. 3. In Cool Mode, only Cool setting temperature can be adjusted. 4. *** The Heat / Cool setting temperature will be confirmed.        Fan Operation If FAN ON is selected, fan runs continuously. If FAN AUTO is selected, fan runs only when the Heating or Cooling system is on. Fan will be turned off 2 minutes after the Heating / Cooling system is off.   Fan Mode setting:  1. Press SET button to enter Setting Menu. 2. Press UP or DOWN button to display FAN and press SET button. 3. Press UP or DOWN button to select FAN ON / FAN AUTO. 4. Press MODE button to confirm the setting and return to Setting Menu. 5. *** Press MODE button to resume to Normal display mode    Advanced Setting Advanced Setting contains Function Setting Selection and Temperature Calibration and Room Temperature Display.  Function Setting Selection           1. Press and hold SET and DOWN buttons for 2 seconds to enter Advanced Setting Mode. 2. The left letters represent Function Type; the right letters represent the settings. 3. Press UP or DOWN button to adjust the setting. 4. *** Press MODE button to select Function Type or to return to Normal Display Mode at the end of Function Setting selection.  Table of the Function Setting Selection Function Type Setting Description LCD Display Fan Control  FC E (Electrical Heat) (default) O (Gas/Oil Heat) Temperature Display Unit  dE °C  °F (default) Temperature Control Span  SP 05 (+/- 0.5°C ) 10 (+/- 1.0°C ) 10 (+/- 1°F) (default) 20 (+/- 2°F) 12hr/24hr Selection  hr 12 (default) 24 Heater Minimum-Off Delay dL S (10 seconds) (default) L (4 minutes off time)    Temperature Control Span : It controls how much the room temperature can be deviated from the setpoint. A smaller degree will result in a more accurate control. A larger degree will result in less on/off cycling and it usually saves more energy.  Fan Control : It should be set according to the type of Heating system used. Select “E” for Electric Heat, fan will be On when Heat is On. Select “O” for Gas Heating or Oil Heating, fan will NOT be on when Heat is On. Heater Minimum Off Delay : It should be set according to the heater type. Select “L” if compressor is used for heating. Select “S” when a compressor is not used.   Temperature Calibration This thermostat is calibrated at factory and calibration is generally not required. However, in the event that a deviation is found.    1. In Normal Display Mode, press and hold UP and DOWN buttons for 5 seconds to change the temperature calibration display and the current temperature will flash,   2. Press UP and DOWN button to calibrate the temperature. The maximum range to be adjusted is +/- 3.0°C or +/- 6°F, in step of 0.5°C / 1°F. 3. ***Press MODE key to confirm the setting and return to Normal Display Mode.      Specification  WT530T Transmitter 1. RF transmission:      915MHz 2. Power Supply:                  2 x AAA Alkaline Batteries 3. Temperature Measurement:    0 - 40°C / 32 - 99°F 4. Accuracy:                   ±0.5°C / 1°F 5. Resolution:                     0.5°C /1°F 6. Heat/Cool Setting:      5 - 35°C / 40 - 95°F 7. Sensing Element:        NTC Thermistor     RT530R Receiver 1. RF transmission:                 915MHz 2. Power Supply:                  24Vac 50/ 60Hz     3. Rating:          24Vac 50/ 60Hz 1A Max 4. Relay Contact Voltage:  24Vac Max. 50/60 Hz 5. Relay Contact Current:  1A Max.   6. Operating Temperature:  0 - 50°C / 32 - 122°F 7. Storage Temperature:                -5 - 50°C / 23 -122°F       FCC STATEMENT Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:      Reorient or relocate the receiving antenna.     Increase the separation between the equipment and receiver.     Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.     Consult the dealer or an experienced radio/TV technician for help.  The Responsible party information: World Excel Company Limited Room B ,26/F, Capital   Trade Centre, 62 Tsun Yip St.,   Kwun Tong, H.K. Technical Helpline Tel: 852 - 2304 0993 <Down> button  Function Type    <SET> button   Setting  <Up> button *** The operation will return to Normal Display Mode if no key is pressed for 10 sec.

Navigation menu