Wistron NeWeb CB1GSKV2C Intergrate with certified module-End product User Manual UMC SKV2C Rev 05 20160426

Wistron NeWeb Corporation Intergrate with certified module-End product UMC SKV2C Rev 05 20160426

User manual

   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 1 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document          UMC-SKV2C User Manual                    The document contains proprietary information which is the property of Wistron NeWeb Corporation and is strictly confidential and shall not be disclosed to others in whole or in part, reproduced, copied, or used as basic for design, manufacturing or sale of apparatus without the written permission of Wistron NeWeb Corporation.
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 2 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Revision History Issue Date  Version  Description 2016/03/25  0.1  Initial Issued 2016/03/28  0.2  Add LTE P/D switch and appendix I 2016/03/30  0.3  Add assemble pictures including SMCC/Honey board/external antenna connection 2016/04/08  0.4  Update the control command for Zigbee 2016/04/26  0.5  Add warning messages and some notes
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 3 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Contents 1. Introduction .......................................................................................................................................... 4 2. Test Setup Configuration ..................................................................................................................... 5 2.1 Power Supply and Debug Console Connection ...................................................................... 5 2.2 Antenna Connection ................................................................................................................. 6 2.3 Whole DUT connection ............................................................................................................ 7 2.4 Hardware Component Introduction ....................................................................................... 8 3. Zigbee Test .......................................................................................................................................... 10 3.1 COM port Setup in a Windows Host PC ................................................................................ 10 3.2 Enter Zigbee Control mode .................................................................................................... 12 3.3 Zigbee Test Command ............................................................................................................ 12 4. LTE B4/B13 Test ................................................................................................................................. 13 4.1 For LTE connection to Test Equipment ................................................................................... 13 4.2 LTE Rx Primary/Secondary switch for OTA ........................................................................... 14 Appendix I ................................................................................................................................................... 16
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 4 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 1. Introduction This User Manual of Victor CB (Communication Board) module is to describe how to use the  following  sections  for  lab  test  by  specific  qualified  engineers  or  technicians. Furthermore,  this  module  is  NOT  intended  for  commercial  use  but  designed  as  part  of Smart  Meter  product  which  mainly  provides  4G  LTE  WAN  access  and/or  Zigbee  HAN access  capabilities.  For  the  procedure  of  CB  installation  into  electric  meter  and  the operation of CB in assembly factory, that information is described in assembly instruction document.     FCC Interference Statement This module complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This module may not cause harmful interference and (2) this module must accept any interference received, including interference  that may cause  undesired operation.  Radiation Exposure Statement This  module  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled environment.  This  module  should  be  installed  and  operated  with  minimum  distance  of 20cm between radiator and human body.  Any  changes  or  modifications  not  expressly  approved  by  the  party  responsible  for compliance could void the user’s authority to operate the device.
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 5 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.       Test Setup Configuration 2.1 Power Supply and Debug Console Connection  Power on Sequence: I. Connect 30-pin-to-Jig-baord cable II. Attach AC-DC Adaptor & USB Debug Port Cable III. Wait for 20 seconds when system ready [Caution] Improper power on sequence might lead to system boot-up failure!   Interface Board  DUT (CB)
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 6 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.2 Antenna Connection        Connect to LTE primary antenna Connect to LTE diversity antenna Connect to Zigbee antenna
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 7 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.3 Whole DUT connection
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 8 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.4 Hardware Component Introduction   AC-DC 5V Adaptor   Interface Board      Victor CB
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 9 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document   Honey Board  Extension Cable  External Antenna
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 10 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.       Zigbee Test 3.1 COM port Setup in a Windows Host PC Install PuTTy for connection to DUT, refer to http://www.putty.org/
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 11 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document  Serial Line: COMxx ; Speed: 115200 ; Connection Type: Serial Note: If there is no response when typing anything in the com port, please see the appendix I.
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 12 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.2 Enter Zigbee Control mode  Enter Zigbee control mode: ember-mfgtool 3.3 Zigbee Test Command Freq. channel setting:        mfg channel set 11 Channel Low : 11 -> CH11 Channel Mid : 18 -> CH18 Channel High : 25 -> CH25   Power level/mode setting:        mfg power set -3 mode 2 Enable callback:           mfg start 1 Single tone output:           mfg tone start Single tone output stop:        mfg tone stop Modulation signal output:        mfg stream start Modulation signal output stop :     mfg stream stop
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 13 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 4.     LTE B4/B13 Test It is suggested to use Anritsu MT8820C for RF conductive test For LTE radiation tests, the LTE antenna gain lists below.  LTE Main Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 4.5 dBi ~ 5.0 dBi    LTE Diversity Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 2.5 dBi ~ 3.0 dBi    4.1 For LTE connection to Test Equipment When UMC-I210C is installed with test SIM, it can automatically connect to tester, such as Anritsu 8820C.
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 14 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document 4.2 LTE Rx Primary/Secondary switch for OTA Login the cli mode (only in service mode 1,4)   Telnet IP:192.168.0.1 Port: 35003
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 15 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document     disable-primary-rx -p  Disable Primary Rx   disable-secondary-rx -p  Disable secondary Rx   restore-rx-default -p  Enable Primary/Secondary Rx Note: The setting will persist across reboots
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 16 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Appendix I Change System Service Mode for Serial Port Control Step 1: Confirm windows capture the device
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 17 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Step 2: Establish SSH connection by Putty in windows    Hostname: root@192.168.0.1    port: 35001 Connection type: SSH  Click “NO” for continue without saving ssh key
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 18 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Step 3: Login with one time password.  Login with one time pass word Look up the corresponding password in the OTP list below. Ex: 9998  NOB YET HECK CAKE CUR MALE Enter command: newrole -t unconfined_t   Look up the corresponding password in the OTP list below. Ex: 9997  VOID COON MEET TEST OVER MOD  One Time Password (OTP ) List: 9989: ACTS EDGY AMID TAG TREE SLIM 9990: DO SAT HI SOIL A HATE 9991: SOON CUE PEG SAUL LACK IFFY 9992: SALK NAVY ROVE INCA LOON HIT 9993: GULF NOUN HUH TAKE OLIN SILO 9994: WAYS AUNT GAUL IRK TALK ROSE 9995: HAT PRY CLAW CHIC GAP CHIN 9996: MAC OLAF GLOM OVAL SAC LO 9997: VOID COON MEET TEST OVER MOD 9998: NOB YET HECK CAKE CUR MALE
   Subject: UMC-SKV2C User Manual                                                                       REV: 0.5                                                                                                                                                                               PAGE 19 OF 19  Wistron Neweb Corporation Proprietary & Confidential     Design Document Step 4: Set system service mode   ucfg set config gridnet passedmfg 0 prctl setmode 1      Set system service mode to 1  prctl getmode        Read the system mode

Navigation menu