Welltronic Technology SIGMA-S400 Sigma Industrial remote controller User Manual Sigma handbook EN V120 FCC

Welltronic Technology CO. LTD. Sigma Industrial remote controller Sigma handbook EN V120 FCC

user manual

SigmaIndustrial RemoteControllerOPRATION GUIDESigma S300 -6 single step buttonsSigma S302 -6 Buttons, 2 double step buttons+4single step buttonsSigma S304 -6 Buttons, 4 double step buttons+2single step buttonsSigma S306 -6 double step buttonsSigma S400 -8 single step buttonsSigma S402 -8 Buttons, 2 double step buttons+6single step buttonsSigma S404 -8 Buttons, 4 double step buttons+4single step buttonsSigma S406 -8 Buttons, 6 double step buttons+2single step buttonsSigma S408 -8 double step buttonsSigma S40xAB -8 Buttons + A/B select function
STOPButtonA/BindicatiorStatusindicatorFunctionbuttonsSigma makes convenience!!ΣΣTransmitter specification-Frequence range :419.2MHzTransmitting power : 10mW<Modulation mode :FSKTransmitting mode :F1DSecurity codes : 4.2billion setsPower source :2 x AA (LR6) 1.5V alkaline batteriesPower consumption : 8mA<Opration temperature :-10°C~+40°CSize S30x / S40xS50x / S60x230mm X 70mm X 43mm:175mm X 70mm X 43mmWeight S30x / S40x 250gS50x / S60x 310g(batteries included):ΣΣIndicators of transmittor-1. Red ON(2sec When STOP Button is pressed down,the Red LED would light on 2 secs. Now it is in theSTOP Mode.):2. reen ON After clockwise turning ON the STOPbutton, press any button(or press the Start-up Button,it depends on the set up) then the Green LED wouldlight on. It is in the Start-up Procedure.G:3. reen flash During operation, the Green LED wouldflash every 2 secs.G:4. ed flash During operation, if the Red LED flashesper sec., it is telling you that the battery power is low.Please renew 2 x AA alkaline batteries.R:5. A/B indicator In the type S40xAB,S50xAB andS60xAB, this indicator can show which hoist (A and/orB) is controlled.:S30x/S40xTransmitterS50x/S60xTransmitterΣΣEnclosure rating: IP600.03mW
Sigma makes convenience!!ΣΣΣΣReceiver specification-Frequence range : 419.2MHzReceive Sensitivity : 115dBm<-Security codes : 4.2billion setsPower source :AC110VPower consumption :W<8Opration temperature :-10°C~+40°CSize :S50x / S60x240mm X 120mm X90mmS30x / S40x220mm X 120mm X75mmWeight :S50x / S60x 950g(Cable excluded)S30x / S40x 760gContacts ability : 5A @ 250VACEnclosure rating: IP60S30x/S40x ReceiverS50x/S60x ReceiverCurrent rating : 0.5 A
Sigma makes convenience!!ΣΣΣΣIndicators of receiver -1. (GreenPower indicator. It lightens on when the power is fed in.PWR ):2. :Green ON - The Receiver got the Start-up command, and is in WorkingMode, ready for the operation anytime.Green OFF - The Receiver is still in the Stand-by Mode, and it needs toreceive the Start-up command to operate.Red Flash - The Receiver is in the Security Code Learning Mode.WORK3.Red ON -The RF signal is received.Red OFF Non RF signal or low signal.RF :-4. :Red ON - The Receiver is waiting for the RF signal.Red OFF - The RF signal received and decoded correctly.Red fast Flash 5 times/sec The RF Signal received, but the SecurityCode does not match with each other.Red slow Flash 1 times/sec The RF signal received, but it is not Sigma'sCode. The receiver is interfered by other RF signals.DATA-,-,ΣΣOpration of Sigma-Start upPWR LEDSTOP STOPStart-up Set-upprogram Green LEDStart-upStart-up WORK LEDGreen LED-1. Power on the receiver and check the lightening or not.2. Turn the Button clockwise and release, the will spring up.(Please placed batteries into the transmitters at first,if have't placedbatteries)3. Push any button, or the Button (if already set by). Wait till the Transmitter indicator lightenen,and the Transmitter will send the command to the Receiver.Mean time, if the Receiver got the command, itswill lighten. Release the pressed button(s), and the transmitter'swill be off.4. It is ready, and you can operate now.Sigma-1. Push down the Button anytime, the transmitter will send out thecommand to the Receiver. The Receiver will cut down any output,and the should be shut off. The transmitter's willstill lights on and sending command 2 secs.2. Now, you may power off the Receiver.Power offSTOPSTOPWORK LED RED LEDSTOP
Sigma makes convenience!!ΣΣΣΣCautions-①②....If you are not a professional, please do not install or uninstall .The equipments (or/and ) would be damaged from your errors.The equipments must have the , ,, and other safety protecting equipments.To avoid the influence caused by electromagnetic wave, the location ofreceiver should be away from motor/converter/welding machine and soon which may bring it.The 's receiver should not be mounted inside of any metal box. Itwill weaken the strength of the RF signals, and may cause bad receivingcondition for your operation. The receiver should be mounted outside ofany metal box or other safe places that wouldn't cause bad receivingcondition.If you will not use for a long time, about a week or more, thebatteries should be taken off to prevent the batteries electrolyte leakageto etch the .For PERMANENTLY CONNECTED EQUIPMENT, a readily accessibledisconnect device shall be incorporated external to the equipmentSigmaSigmaSigmaSigma.Main Power N.F.B. Main Power RelayLimits SW.PCB③④⑤⑥
Sigma makes convenience!!ΣΣΣΣSigma Functions-1. Interlocked -Left/ right button is interlocked from each other.3. ON/OFF -ON/ OFFFF ONIn this Function, you can set the Left/ Right Button as function.The Left Button as , and the Right Button as . (This functioncould be set by passing EMS.)O2. Non_Interlocked -Left/ right button is not interlocked, and its Two kinds of movements asbelow.①②Normal ON OFFToggle ONOFF- Push down is , and release to be .- Push down would output . Release and push down again,output . (This function could be set by passing EMS.)5. A/B Selector -Button HButton L Hoist A Hoist BOFF AA+B B OFFLED A/ BThis Function only supports in S40xAB,and in S60 x AB, as the A/B Selector to choose , ,or A + (plus) B to work together. The moves in turns like this, -> ->-> -> (Repeatedly). At the transmitter, it has the correspond-ing to indicate which Hoist being controlled.Button J in S50xABRelay 1Relay 2Relay 1Relay 2Step Step001212Standard Step Special 2nd Step4. Special 2nd Step -This function only supports the Special Two Step Button, and themovement is like the below diagram.6. Start Up mode -For the safety and convenience, Sigma has 2 kinds of Start-up Mode.①②Any button to start up - More convenience, but less safety.Specified button to start up - In S4xx, press at the same time, inS5xx, press , while in S6xx, press to start-up Sigma.This mode could prevent from starting-up by mistake. It provides youmore safety.G+HI+J K+L
Sigma makes convenience!!ΣΣ7. Working Mode -Sigma has kinds of Working Modes to meet the need of various workingplaces.-①No Auto StopSTOPAuto StopContinues LinkAuto Stop Continues LinkAuto StopSTOPAuto Stop- During operation, the Transmitter would not be shutdown automatically. You need to press theButton for shutting down.After starting up, the Transmitter could be automatic-ally shut down after the set time-out period.- After starting up, the Transmitter is set to be continu-ally sending out the RF signals to the Receiver. Thisfunction is for below purposes.a. Preventing from any interfering RF signal that maycut-off the regular signal-sending operation.b. The equipment will be automatically stopped andcut-off any Output, if the Receiver moves beyondthe effective remote distance.Notes -*1 - In the previous ode and mode:The Transmitter consistently consumes power all the time. You needto additionally set up the time. It can be selected among3, 1, 2, 5, 10 minute(s) for shutting down the Transmitter. To resumethe operation, you can press the Button at first, then releaseit to spring-up---- if the occurred.*2 - Working Modes are for you to choose among Safety, Power Consum-ption, and Convenience. The below table is for your reference.Sigma②③②m③ContinuesLinkAuto StopNoAuto StopSafetyPowerConsumptionConvenience HighMiddleLowLowLowHighHighLowMiddle
Sigma makes convenience!!ΣΣSigma S300 series installation wiring diagramMainMain12313141516PowerFUSE 0.5AA/B ComAStep 1BStep 1456C/D ComCStep 1DStep 118C/D Step 2789E/F ComEStep 1FStep 119E/F Step 2FUSE 5AABCDEFSigma S300 series wiring101112A/B 2ComAStep 2BStep 2
Sigma makes convenience!!ΣΣSigma S400 series installation wiring diagramMainMain12313141516PowerFUSE 0.5AA/B ComA Step 1B Step 117A/B Step 2456C/D ComC Step 1D Step 118C/D Step 2789E/F ComE Step 1F Step 119E/F Step 2101112G/H ComG Step 1H Step 1 (Hoist A)20G/H Step 2 (Hoist B)FUSE 5AABCDEFGHSigma S40x series wiring
You are cautioned that changes or modifications not expressly approved by theparty responsible for compliance could void your authority to operate theequipment.This device complies with part 15 of the FCC rules. Operation is subject to thefollowing two conditions(1) This device may not cause harmful interference and(2) this device must accept any interference received, including interferencethat may cause undesired operation.-