Confidential    WPW-220 Wireless Power     Switch (US)    Installation instructions      Table of Contents 一、Product Overview .......................................................................................... 1二、Feature............................................................................................................ 1三、Installation Operation..................................................................................... 2四、Precautions ..................................................................................................... 2五、Troubleshooting ............................................................................................. 3
 Confidential  1一、Product Overview 1. Product Name:Wireless Power Switch (US) 2. Model:WPW-220 3. Power supply:100~120VA C  4. Dimensions  (mm)  and  Accessories:82 x 45x 36mm The  controller base, manual      二、Feature 1. Radio  transmission,  sent  to  the  receiving  host  on  /  off  signals to control the power supply or power outlet execution, also by phone to remotely control home electrical equipment, improve convenience of life. 2. Series compatible, can be used with wireless door detector (SCT-230) or  wireless  displacement  detector  (SMT-230)  do  not  even  move control, such as corridors auxiliary lighting at night. 3. Easy to use, placed in a power outlet, press the SET button, so that the host is connected to each other to complete the setup. 4. It  can  be  connected  to  other  appliances.  Transparent  LED  keys  to control the power state, the red light indicates that the power output. 1. Setting LED status 2. Button (with warning lights) 3. (SET) set key 4. 3-point power outlet 5. 3-point power plug
   25. Both  wireless  signal  router  functions,  transmission  system  may extend the terminal host and detector distance.  三、Installation Operation 1. First WPW-220 connected to the power outlet, then will enter the boot mode, the blue light on the front of  the boot will be  completed after about 90 seconds of constant light. If you want to skip this program, press the SET button. 2. To  register  the  first  to  prepare  the  upper  device  -  Press  Gateway (Host)  or  short  press  Router  (router)  behind  the  SET  button,  then press the SET button on the side of the machine. In this case the host device  and  this  opportunity  within  about 15  seconds  flashing  lights; when the connection is successful, the host device and the machine's LED  light  will  flash  at  the  same  time  long  after  the  close,  that  has successfully paired connection. 3. If  the  connection  fails,  the  second  party  device  will  flash  after  15 seconds in length at the blue lights. 4. Transparent  front  LED  button  to  control  the  power  state,  blue  light indicates power output. 5. Power  Measurement:  When  I  want  to  measure  the  electrical connector  socket  on  the  machine,  turn  the  power  output  starts automatically  calculate  the  voltage,  current,  power.  (Need  to  use power measurement value for at least one hour) 6. Price calculation: please set by the web user interface peak, off-peak electricity price and time, and set the time of desire accumulated (in months, up to three months), the system automatically calculates the total price, and to distinguish between peak, off-peak electricity (as far back in 1 year) 7. Power  measured  values  via  web,  mobile  APP,  wireless  terminal controller  made,  APP  achieved  price  calculated  values  via  web, phone. 8. Releasing the connection: Press the sides of the machine SET button until flashing green light goes out and then release, the unit for about three  seconds  after  the  long  flashed  blue  lights,  that  means  lifting successful connection.  四、Precautions 1. The maximum current load of 10A / 120V, 1200W
   32. Power measurement ranges: (1) Measuring voltage range:100~130VA C  (2) Measuring Current Range:0.3~10A (3) Measuring power range:30~1300W (4) Measuring the cumulative time in months, up to three months (as far back in 1 year) 3. As the wireless signal router can connect up to 16 wireless detectors. 1 set of system can accommodate up to 16 wireless signal router. 4. Wireless signals in series to host up to three relay.  五、Troubleshooting 1. Abnormal  situation:  WPW-220  LED  indicator  flashes  the  number  of abnormal, can not recognize the connection status. Treatment:            a. Make sure the power outlet is connected properly and whether the power supply is normal supply.            b. Re-plug power, restore factory value, and set the connection again.            c. If the above situation to handle invalid, please contact your dealer. 2. Abnormal  situation:  unable  to  connect  with  the  wireless  host. Treatment: Make sure the distance WPW-220 and the host or between repeaters, whether in unsheltered effective distance of 300 meters straight. If the shelter will shorten the effective distance, you can shorten the distance between the two, or join repeaters, re-test without improvement.  Specifications UIS/Wireless Power Switch Model No.  WPW-220 Electrical Specification Transmit Frequency  2.4GHz ISM band, IEEE802.15.4: 2405 ~ 2480MHz Channel NO.  16 Channel (2405MHz to 2480MHz) Operation Range  Up to 200 meters (LOS) RF Nominal output power  15 ± 1 dBm RF Receiver sensitivity  -97 dBm(typ) Power Consumption  Working:    ~1.87W
   4Standby:    ~1.32W LED Indicator  Blue 1PC/Red 1PC LED Status: Relay (ON/OFF) Operation Interface  Push button switch for setting on the side Push button switch for Relay on/off in front Operating Voltage  100~120VAC 50/60 Hz Resistive Load  10A/120VAC, 1200W max. Inductive Load (Single Face)  0.5HP/120VAC Over Current Protection  11A Measure Voltage Range  100~130VAC Measure Current Range  0.3A~10A± 10% Measure Power Range  30~1300W± 10% Software Protocol Version  ZHA1.2x Reconnect scenario Reconnect scenario will be implement when device in ORPHAN state   STEP 1 : Reconnect to original network 3 times every 5min. If not success, enter STEP-2   STEP 2 : Reconnect to original network 3 times every 30min. If not success, enter STEP-3   STEP 3 : Reconnect to original network every 60min repeatedly. Environmental Requirement Operating Temperature  -10°C to 50°C Storage Temperature  -10°C to 70°C Humidity  90% RH Max., Non-Condensing Mechanical Specification Dimension (WxHxD, mm)  82 x 45x 36 Weight    70g
5Notice : The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.低功率電波輻射性電機管理辦法第十二條  經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。第十四條  低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。  低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。