    PIN Pad   PP190 Programmer’s Manual   Personal ID Number Pad    Revision 0  2014-02-06
PIN Pad 190 Programmer’s Manual   2014-02-06                       Page  1 Uniform Industrial Corp.  Proprietary and Confidential        Total  160 pages FEDERAL COMMUNICATIONS COMMISSION STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  You are cautioned that any change or modifications to the equipment not expressly approve by the party responsible for compliance could void your authority to operate such equipment.
PIN Pad 190 Programmer’s Manual   2014-02-06                       Page  2 Uniform Industrial Corp.  Proprietary and Confidential        Total  160 pages NOTICE The issuer of this manual has made every effort to provide accurate information. The issuer will not be held liable for any technical and editorial omission or errors made herein; nor for incidental consequential damages resulting from the furnishing, performance or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated without the prior written consent of the issuer. The information provided in this manual is subject to change without notice.  第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、 大功率或變更原設計之特性及功能。  第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。  前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。  AGENCY APPROVED - FCC class B - CE class B  WARRANTY This product is served under one-year warranty to the original purchaser. Within the warranty period, merchandise found to be defective would be repaired or replaced. This warranty applies to the products only under the normal use of the original purchaser, and in no circumstances covers incidental or consequential damages through consumers’ misuse or modification of the products.
PIN Pad 190 Programmer’s Manual   2014-02-06                       Page  3 Uniform Industrial Corp.  Proprietary and Confidential        Total  160 pages Document History Document Version Apply to FW version Change 0A 190BL00A 190SC00A 190PM00A First SQA 0B 190BL00A 190SC00B 190PM00A 1. First SQA debug. 0C 190BL00A 190SC00C 190PM00A 1. Second SQA debug. 2. Add new command ”01”、”16”. 3.  Add new command “94”、”96”. 4. Add new function “self diagnostic”. 0D 190BL00A 190SC00D 190PM00A 1.  Third SQA debug 2. Add new function “Remote key injection” (R00 ~ R02) 0E 190BL00A 190SC00E 190PM00A 1.  Fourth SQA debug 2. Add new function RTC(Real time clock) and new command “P18” 0F 190BL00A 190SC00F 190PM00A 1. Fifth SQA debug a. Modify command 02. b. Modify command 08. c. Modify command 72. d. Modify command Z2 to response <EOT> at end of transmit. e.  Modify command Z60. f.   Modify command 70 (PIN Entry Request  with DUKPT) to check exist of DUKPT key early.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page4 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Table of Contents Section 2 PP190 Setup & Diagnostic Menu __________________________________ 7  Start Up Self Test _____________________________________________________________ 7  Call up Diagnostic Menu ______________________________________________________ 7  Diagnostic Menu 1: HW Tests __________________________________________________ 7  Diagnostic Menu 2: Display Info ________________________________________________ 8  Diagnostic Menu 3: Set LCD Backlight ___________________________________________ 8  Diagnostic Menu 4: Set Keypad Beep ____________________________________________ 8  Diagnostic Menu 5: Update Password ___________________________________________ 8  About USB virtual COM port (only applied on USB version) _________________________ 9 Section 3  Message format ______________________________________________ 10  Notation Conventions ________________________________________________________ 10  Message frame summary _____________________________________________________ 11 Section 4    Administration and maintenance messages _______________________ 12  Message 01 Self Test ________________________________________________________ 12  Message 02 Load Master Key _________________________________________________ 14  Symmetric Keys Loading Authentication ________________________________________ 18  Message 04 Check Master Key ________________________________________________ 20  Message 05 Load Serial Number _______________________________________________ 22  Message 06 Get Serial Number ________________________________________________ 23  Message 07 Test DES Implementation __________________________________________ 24  Message 08 Select Master Key ________________________________________________ 25  Message 09 Communication Test ______________________________________________ 26  Message 11 PIN Pad Device Connection Test ____________________________________ 28  Message 13 Adjust COM1 Baud Rate (RS-232 version only) ________________________ 29  Message 16 Remote self-test request ___________________________________________ 31  Message 17 Request random number __________________________________________ 32  Message 18 Get/Set PIN pad system time _______________________________________ 33  Message 19 Query Firmware Version ___________________________________________ 35  Message 1J Turn ON/OFF LCD Backlight ________________________________________ 37  Message 1M Setup Keypad Beeper _____________________________________________ 39 Section 6    Online transaction messages with Master/Session Keys (MK/SK) _____ 41  Message 70 PIN entry request (MK/SK) _________________________________________ 41  Message 71 Encrypted PIN Block Response _____________________________________ 44  Message 72 PIN Entry Cancel _________________________________________________ 47  Message Z0 Move Display Cursor ______________________________________________ 48  Message Z1 Reset State ______________________________________________________ 49  Message Z2 Display String ____________________________________________________ 50  Message Z3 Display Line Prompts _____________________________________________ 53
PIN Pad 190 Programmer’s Manual   2014-02-06  Page5 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Z2 / Z3 Authenticated mode with fixed prompt ___________________________________ 56  Z2 / Z3 PIN entry mode with fixed prompt _______________________________________ 56  Message Z2 Display String with Authentication Code _____________________________ 57  Message Z3 Display Line Prompts with Authentication Code _______________________ 59  Example to use Z2 / Z3 with Authencation Code. _________________________________ 61  Message Z42    Read Key Code ________________________________________________ 62  Message Z43    Read Key Code Response _______________________________________ 63  Message Z50    String Entry Request ___________________________________________ 64  Message Z51    String Entry Response __________________________________________ 66  Message Z60    PIN entry request with external prompt (MK/SK)_____________________ 67  Message Z62    PIN entry request with customized prompt (MK/SK) _________________ 69  Message Z64    Query Key Check Value (KCV) ____________________________________ 72  Message Z65 Key Check Value Response _______________________________________ 73  Message Z66    Message Authentication Code (MAC) Request ______________________ 74  Message Z67    Message Authentication Code (MAC) Response _____________________ 77  Message Z7 Turn ON/OFF CANCEL Message Display _____________________________ 79  Message Z8 Set Idle Prompt __________________________________________________ 80 Section 7  Online transaction messages with Derived Unique Key per Transaction (DUKPT) ______________________________________________________________ 81  Message 60 Pre-authorization PIN Entry Request _________________________________ 82  Message 62 Pre-authorization Amount Authorization Request ______________________ 84  Message 70 PIN Entry Request (DUKPT) ________________________________________ 85  Message 71 Encrypted PIN Block Response _____________________________________ 87  Message 72 PIN Entry Cancel _________________________________________________ 89  Message Z60    PIN entry request with external prompt (DUKPT) ____________________ 90  Message Z62    PIN entry request with customized prompt (DUKPT) _________________ 92  Message 76 PIN Entry Test Request ____________________________________________ 95  Message 7A KSN output format _______________________________________________ 96  Message 90 Load First Initial Key Request ______________________________________ 97  Message 91 Load Initial Key Response _________________________________________ 99  Message 94 Load Second Initial Key Request ___________________________________ 100  Message 96 Select Active Key Set ____________________________________________ 101 Section 8    Remote key injection method __________________________________ 102  Message R00 Load Vender Public Key _________________________________________ 103  Message R01 Update RSA Key _______________________________________________ 106  Message R02 Remote Key Injection ___________________________________________ 112 Section 9    EMV Level 2 transaction messages _____________________________ 117  Message T51 Terminal Configuration Setup ____________________________________ 118  Message T52 Terminal Configuration Setup Response ___________________________ 121  Message T53 Certificate Authority Public Key Setup _____________________________ 122
PIN Pad 190 Programmer’s Manual   2014-02-06  Page6 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message T54 Certificate Authority Public Key Setup Response ____________________ 125  Message T55 EMV Application Configuration Setup ______________________________ 126  Message T56 EMV Application Configuration Setup Response ____________________ 131  Message T61 Start Transaction _______________________________________________ 132  Message T62 Start Transaction Response ______________________________________ 134  Message T63 Get Transaction Result’s Data ____________________________________ 136  Message T64 Get Transaction Result’s Data Response ___________________________ 137  Message T65 Get Online authorization Data ____________________________________ 138  Message T66 Response of Get Online authorization Data message _________________ 139  Message T71 Send Online Authorized Code ____________________________________ 140  Message T73 Send Issuer Script Command ____________________________________ 142  Message T74 Send Issuer Script Command Response ___________________________ 143  Message T75 Revocation List Setup ___________________________________________ 144  Message T76 Revocation List Setup Response__________________________________ 145  Message T77 Exception List Setup ____________________________________________ 146  Message T78 Exception List Setup Response ___________________________________ 147 Appendix A  Key management __________________________________________ 148 Appendix B    PIN Block Format _________________________________________ 156  ANSI x9.8 format (MK/SK, DUKPT, and Offline clear text PIN entry) _________________ 156 Appendix C    Fixed Prompts for Z2/Z3 authenticated mode ___________________ 157 Appendix D    Fixed Prompts for Z2/Z3 PIN entry mode ______________________ 159
PIN Pad 190 Programmer’s Manual   2014-02-06  Page7 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Section 2 PP190 Setup & Diagnostic Menu  Start Up Self Test PP190 will perform a series of self-tests during start up, which include:  Internal firmware checksum: PP190 will verify the internal firmware checksum to ensure the integrity of the firmware program. If firmware checksum error, PP190 will show following prompt and reject further commands:      Security Memory Integrity: PP190 will verify secret personalization information written in the Battery Powered Key (BPK) register of the CPU. If BPK verification failed (possibly by security breach or internal battery exhausted,) PP190 will show following prompt and reject further commands:      Call up Diagnostic Menu   Press function key [CLR] + [3] (quickly press ‘3’ after [CLR] released) of PP190 will call up diagnostic menu when PP190 in idle state. The default 2 passwords for diagnostic menu are “87806799” (both passwords)    Diagnostic Menu 1: HW Tests  DISPLAY ACTION Display Test Display two pages of test pattern: First page is turn on all pixels to check if there are any dot ** A L E R T ** ROM CHKSUM FAILD ** A L E R T ** PED WAS TAMPERED DISPLAY ACTION (Idle prompt)   Power on.   Press [CLR]+[3]   Password 1?  Input first setup password and press [ENTER]   Password 2?  Input second setup password and press [ENTER]   HW Tests  Display Info Set LCD Backlight Set Keypad Beep Update Password  Use left button [-] and right button [-] to scroll up and down. [ENTER] to execute.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page8 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages damage. Press any key or wait 10 sec to continue. Second page shows PP190 character sets. Press any key or wait 5 sec to leave. Keypad Test PP190 will echo user’s input key at line 2. Press [CAN] to leave this test.    Diagnostic Menu 2: Display Info  DISPLAY ACTION Show SerialNum Display current serial number. Refer to message 06. Show Version Display current firmware version.   Diagnostic Menu 3: Set LCD Backlight  DISPLAY ACTION Light Always ON Light Auto OFF  First item will set LCD backlight always on. This setting is the same with message 1J with parameter 1. Second item will set PP190 enable its backlight in following situation: a. Any key is pressed. b. PIN entry command is working c. Selecting Menu. And backlight will automatically turn off after 3 seconds of above operation ends.    Diagnostic Menu 4: Set Keypad Beep  DISPLAY ACTION Beep ON Key press with beep.   Beep OFF Key press without beep.     Diagnostic Menu 5: Update Password  DISPLAY ACTION
PIN Pad 190 Programmer’s Manual   2014-02-06  Page9 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages                    About USB virtual COM port (only applied on USB version) PP190 USB version will identify itself as a virtual COM port for Windows 2000/XP device enumeration. When Windows requests PP190’s device driver, please provide a directory name which contains PP190 USB driver, and answer “proceed anyway” when prompted with driver certification questions.   The baud rate of PP190 virtual COM port is determined by the application program. When AP calls Windows API to open COM port, PP190 and Windows virtual COM port driver will adjust its baud rate according to the parameters sent to API function.          Update Password1  PP190 will show following message:   NEW PASSWD   ****   CONFIRM PASSWD   ****   User should press 1st  password, press [ENTER] to enter 2nd password, then press [ENTER] to finish input. If two passwords mismatch the password will not be changed. Password must have 4 characters at least, with maximum 8 characters.   Update Password2  PP190 will show following message:   NEW PASSWD   ****   CONFIRM PASSWD   ****   (Usage is the same with password 1.)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page10 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Section 3  Message format This chapter details the format of messages exchanged between the host and PIN Pad.   Notation Conventions The following conventions are used to make the description of messages more readable:  Control Codes Control codes (non-displayable codes) are represented by two to three capital letters enclosed in angled brackets  “<>“. This PIN Pad uses 12 control codes in total. Their actual code, when referenced, is represented by two hex digits enclosed in angled brackets, <0F> for example. The following table lists their usage and value in hex codes.  CODE HEX VALUE USAGE STX 02 Denotes the beginning of a message frame ETX 03 Denotes the ending of a message frame EOT 04 Indicates communication session terminated ACK 06 Acknowledge of message received SI  0F  Denotes the beginning of a message frame SO 0E Denotes the ending of a message frame NAK 15 Indicates invalid message received SUB 1A Message parameter follows FS 1C Field separator GS 1D Message ID follows  [LRC] Each message frame transmitted is followed by an LRC byte to detect communication error. This byte should be regarded as part of the message frame but comes after the ending delimiter character. [LRC] is used to represents this LRC byte in describing message frames. LRC is calculated as an XORed value of every byte after start code in the message frame except itself, that means from the next byte of <STX> or <SI> through the <ETX> or <SO> byte.  [item] A descriptive item name enclosed in bracket denotes a string or data byte that has no fixed value.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page11 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message frame summary Data exchanged between PIN Pad and host computer are grouped into “message frames”. Each message frame has one of the two frame formats listed below:  <STX>[message ID][data]<ETX>[LRC]  <SI>[message ID][data]<SO>[LRC] Each type of message has a unique value in its message ID field. In the following texts, we reference a message type by its message ID value, e.g. “message 70”.  Message type Messages exchanged between the Signature PIN Pad and the HOST can be divided into two categories.   One is for administration and maintenance, in general administrative messages have <SI> packet header and will return message to HOST by the same message ID.   The other is for various transactions, in general transaction messages have <STX> packet header, and comes in pair. Even number message packets sends command and data to Signature PIN pad, then odd number message packets returns the result.  Time-out Whenever the PIN Pad sends a message, a response (<ACK> character for acknowledgement or <NAK> character if LRC error occurred) from host is expected. If the PIN Pad does not receive a response within 5 seconds, it will retransmit the last packet. If PIN pad does not receive <ACK> or <NAK> after two retransmit attempts, it will send <EOT> character and this communication session will be terminated.  Transmission Error The PIN Pad expects the host computer to send a NAK when the host decides that an invalid frame is received. When the PIN Pad receives a NAK, it will retransmit its last message. If the message retransmitted is invalid again, then a NAK should be sent by host to request for another try. The PIN Pad will keep on retransmitting until an <ACK> or <EOT> is received.  Packet Error When PIN pad received a good transmission but invalid packet (wrong message id) it will ignore the packet. If the packet has acceptable message id but have wrong format. PIN pad will send <EOT> as error message. When in PIN entry functions it will send more detail error code.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page12 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Section 4   Administration and maintenance messages   Message 01 Self Test Format:   <SI>01[test item]<SO>[LRC] Message length: Fixed 7 bytes. Usage:   Field maintenance users can issue message 01 to do interactive PIN Pad self-tests. Test results will be displayed on PIN Pad.   ’04’ PIN Pad will detect specific pattern of key presses as a “correct” pattern, which is “[F1] [MENU] [F2] 1 2 3 4 5 6 7 8 9 [CAN] 0 [ENTER] [CLEAR]”. Key press pattern other than above will be treated as fail. Issue message 72 will interrupt this test, too. ’05’: PIN pad will display 2 test pages: First one is a full screen of black dots to check for damaged dot. Press [ENTER] or wait 10 seconds to display page 2, which is some characters. Press [ENTER] again to end this test. ’06’: PIN pad will display its serial number on the LCD display. ’07’: PIN pad will execute a communication test, see next page for message flow.  Message element: Field Length  Value and description <SI>  1  <0F> 01  2  Message ID [Test item]  2  01 02 03   04 Keypad test 05 Display test 06 Check serial number 07 Communication test <SO>  1  <0E> [LRC]  1  Checksum  Message flow: (for test item 04 through 06) HOST Direction   PIN Pad Message 01     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     (Execute self test)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page13 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   <EOT> (when test done)   Message flow: (for test 07) HOST Direction   PIN Pad Message 01     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   09 Request Packet <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   09 Response Packet     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   09 Response Packet <ACK> (Good LRC) <NAK> (Bad LRC)     <EOT> (when test done)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page14 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 02 Load Master Key   Format:   <SI>02[Key ID][Key value] <FS>[Usage][Mode]<SO>[LRC]  (with clear text key) <SI>02[Key ID][Key value (ANSI TR31 format)]<SO>[LRC]  (with encrypted key)  Message length: Variable (38 to 94 bytes). Usage: Load Master Keys into PP190. PP190 can store 16 master keys; each has a one digit ID. Master keys are divided into three groups of different functions. Refer to Appendix A: Key management for key usage and ID definition.    PP190 implements multiple security measures to conform Payment Card Industry (PCI) security requirement. In order to load clear text master keys, two authorized people with their password are required. Otherwise the user must issue message 02 with encrypted key value (ANSI TR31 format). See next entity “Symmetric Keys Loading Authentication” for detailed information.  Note: 1. The [key value] field’s format is ASCII string with range ‘0’-‘9’,  ‘A’-‘V’, which represents a hexadecimal byte in two characters, i.e. “1F” represents 0x1F. 2. PP190 requires key loading key (master key #F) to be TDES. 3. Pass key loading authentication and then load new clear text master key will erase all other master keys, to prevent malicious key substitution. For more information refer to “Symmetric Keys Loading Authentication” at page 24.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page15 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message element: Request fame (HOST to PP190) Field  Length  Value and description <SI>  1  <0F> 02  2  Message ID [Key ID]  1  ‘0’ to ‘9’, ‘A’ to ‘F’ (A is not used) [Key value] Var. Hexadecimal string for key value.   Clear text format: 32 bytes for double length, 48 bytes for triple length. TR31 format: 56 bytes for single length, 72 bytes for double length, 88 bytes for triple length. <FS>  1  Field separator.   (Optional, only available in clear text format frame if following [Usage] and [Mode] exists) [Usage]  2  Optional: ANSI TR-31 key usage for clear text frame. Available value are: “K0” for key encryption. (id 0 ~ 9, B ~ F) “P0” for PIN encryption. (id 0 ~ 9) “M3” for MAC calculation. (id B ~ E) If omitted, default value is “K0” [Mode]  1  Optional: ANSI TR-31 key mode for clear text frame. Available value are: ‘D’ for decryption only. (K0 keys) ‘E’ for encryption only (P0 / D0 keys) ‘G’ for MAC generation only (M3 keys) ‘V’ for MAC verification only (M3 keys) If omitted, default value is ‘D’. <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page16 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Request fame – Error message (HOST to PP190) Field  Length  Value and description <SI>  1  <0F> 02  2  Message ID ?  1   [Err msg]  1  ‘1’: KLK does not exist. ‘2’: Key value duplicated with other existing key. ‘3’: Internal fail: fail to allocate memory ‘4’: Internal fail: fail to read key structure ‘7’: Fail to decrypt key value. ‘A’: TR31 format error. ‘B’: Insecure key inject. (New key is longer than  the key used to protect it.) ‘C’: Fail to verify MAC value. ‘E’: Key usage incompatible with key ID.   <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 02 (request frame)     <ACK> /<NAK>/<EOT>   Processing request. If format error, send <EOT> and end. Message 02 (echo of request frame). Verify echo frame. If verify ok, send <ACK>. If packet LRC error, send <NAK>. If host want to cancel key loading procedure, send <EOT>.      Save key value and send <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page17 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Example:   Clear Text Master key to be loaded:    1919191919191919 5B5B5B5B5B5B5B5B The Key ID you want to load:  0 The resulting 02 message :   <SI>02019191919191919195B5B5B5B5B5B5B5B<SO>[LRC]  Encrypted (ANSI TR-31 2005 Key Variant Binding Method)   Key encrypting key (Mkey #F): 1919191919191919 5B5B5B5B5B5B5B5B Master key to be loaded (K0): AA55AA55AA55AA55 3434343434343434 Key Block Header (KBH):      (ASCII) A0072K0TD00N0000 TDES CBC encrypted key value: 7D2D21FC9ECD3EEC BB0A2615BD8F0560 5722120BDFF2CCAC Left 4 bytes of MAC value:    319C3198 The Key ID you want to load:  0  The resulting 02 message:   <SI>020A0072K0TD00N00007D2D21FC9ECD3EECBB0A2615BD8F05605722120BDFF2CCAC319C3 918 <SO>[LRC]  Encrypted (ANSI TR-31 2010 Key Derivation Binding Method) Key condition: Load a double length PIN encryption key to key position #1 Key block protection key (KBPK):   1919191919191919 5B5B5B5B5B5B5B5B PIN encryption key to be loaded:   AA55AA55AA55AA55 3434343434343434 Padded key data:   0080 AA55AA55AA55AA55 3434343434343434 1C2965473CE2 Key Block Header (KBH):      (ASCII) B0080P0TE00N0000 Derived Key block encryption key (KBEK): DB7F2A99D5647A7D D3EDFE3DA7CF5B21 Derived Key block MAC key (KBMK):    87EE6C0795954446 A34A0BB5F305BCE1        (See Appendix A for detail derive process) CMAC of (KBH + Padded key data), using KBMK:    EA391E5834C1AA0C        (See Appendix A for detail CMAC algorithm) Use CMAC as IV to do TDES CBC encryption on padded key data, using KBEK: Encrypted key data: 3C4F5024C59C182F 7165BC870FCB7F63 456AAE07DB736C32 The resulting 02 message:   <0F>021B0080P0TE00N0000 3C4F5024C59C182F 7165BC870FCB7F63 456AAE07DB736C32 EA391E5834C1AA0C<0E>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page18 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Symmetric Keys Loading Authentication  In order to make PP190 accept clear text key loading frame, the key loading authentication must be processed.    [Enter key loading authentication menu] Press [CLR]+[2] on the keypad of PP190, then PP190 will show key injection authentication login screen as following: ENTER PASSWORD 1:  (Default password will be sent to authentic owner separately) The first authorized person come to enter 1st password on keypad and press [ENTER]. Then PP190 will prompt to enter 2nd password if 1st password is correct. If 2nd password is correct, too, PP190 will enter key loading mode and show following menu: KEY INJECT MODE Update Password1 Update Password2 Inject MKEY/IPEK Use [F1] and [F4] key to navigate light bar to “Inject MKEY/IPEK”, then press [ENTER]. Then user is free to load clear text master key by message 02, or load DUKPT initial key by message 90 and 94.  [Timing constraint and message constraint of Key Inject Mode] According to PCI security requirement, PIN pad cannot stay in Key Inject Mode forever. Thus when PP190 entered Key Inject Mode, its internal timer will start to countdown, and its operating system will monitor specific message packets. If any one of following criteria is matched, PP190 will exit Key Inject Mode and reject message 02(clear text form) and 90, 94 command: 1. When PIN pad idled for 60seconds, it will exit Key Inject Mode. (Each time 02 / 90 / 94 / 08 / 96 is succeeded, the 60 seconds counter will reset to 60 again.) 2. When PIN pad has been in Key Inject Mode for 15 minutes. It will unconditionally exit Key Inject Mode. 3. When PIN pad receives messages other than 02 / 90 / 94 / 08 / 86, it will exit Key Inject Mode. 4. When user pressed CAN key on keypad, it will exit key inject mode.  [Master key substitution protection] When user entered Key Inject Mode, PIN pad operating system will set up a new “Key Injecting Session”. The first injected clear text master key in a new session will erase all other master keys. The other master keys loaded in the same session will not erase any other master key. DUKPT key set 0 and set 1 will not erase each other.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page19 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Example flow to load master keys with security: In the following example we assume a bank receives a new PP190 and wants to initialize it before deploy. And want to update some master keys after its deployed. We also assume the master key to be loaded is position 0 and position F; their values are already stored in a Tamper Resistant Security Module (TRSM) in a secure way.  1. The bank must generate two passwords, and make two authorized people to keep them separately. 2. Authorized people must enter KEY INJECT AUTH menu and change password 1 and password 2. 3. After password changed, connect PIN pad to TRSM, enter KEY INJECT AUTH menu again and choose Inject MKEY/IPEK function. 4. Operate TRSM to load master key #F and master key #0.  After step 4 finishes, user can issue other commands to PIN pad (such as message 08 to select key #0 as active master key) or turn it off and deploy it.  5. To load or update master keys at field site, user should issue encrypted command 02.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page20 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 04 Check Master Key Format:   <SI>04[key ID][Key Info Query]<SO>[LRC] Message length: Variable (6 or 7) bytes. Usage: Host sends this message to PIN Pad for checking if the master key with an ID of [key ID] has been loaded or not. Message 04 should be used before loading any master key. Message 04 can be also used to query key information (key usage/mode/algorithm) if the designated key is not empty. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 04  2  Message ID [key ID]  1  Master key ID    (0~9, A~G) [Key Info Query]  1  <Option>, 1: query key information <SO>  1  <0E> [LRC]  1  Checksum    Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 04  2  Message ID [response code]  1  0 Master key not loaded F Master key loaded [Key usage]  2  <Option, if key info query filed is set> “K0”: Key encrypting key. (Master key   for PIN / MAC / Data key) “P0”: PIN key “D0”: Data key “M1”: MAC key for MAC algorithm 1 “M3”: MAC key for MAC algorithm 3 <FS>  1  <Option, if key info query filed is set> <1C>, filed separator [Mode]  2  <Option, if key info query filed is set> “E”: Encryption use “D”: Decryption use <FS>  1  <Option, if key info query filed is set> <1C>, filed separator [Algorithm]  2  <Option, if key info query filed is set>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page21 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages “T”: Triple DES “D”: Single DES <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 04 (request)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Check requested memory location Message 04 (response) <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page22 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 05 Load Serial Number Format:   <SI>05[string]<SO>[LRC] Message length: Variable, maximum length is 21 bytes Usage: Load the PIN Pad with the serial number given in the message frame. PIN Pad will send the whole message frame back to host as a confirmation of good reception. Host should then send an <ACK> to confirm or <EOT> to cancel this serial number loading process if the LRC is good but serial number echoed is incorrect. Follow the standard <NAK> process if an invalid LRC is detected.   Message element: Field  Length  Value and description <SI>  1  <0F> 05  2  Message ID [string]  0..16 Alphanumeric string (0~9, A~Z, a~z) <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 05     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 05 (echo frame) or <EOT> indicate error. <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     (Stores serial number) <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page23 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 06 Get Serial Number Format:   <SI>06<SO>[LRC] <SI>06[string]<SO>[LRC] Message length: Fixed 5 bytes for requesting message, variable for response message (max 21 bytes.) Usage: This message is used to get serial number of the PIN Pad. PIN Pad will send the serial number previously loaded or string of 16 ‘0’s as the serial number if it has not been loaded. Serial number will be displayed on LCD, too. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 06  2  Message ID <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 06  2  Message ID [string]  0..16 String for serial number <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 06 (request)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 06 (response frame) or <EOT> if read error <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page24 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 07 Test DES Implementation Format:   <SI>07[master key][clear text][cipher text]<SO>[LRC] Message length: Fixed 53 bytes. Usage: This message is used to validate DES implementation of PIN Pad. Testing result will be shown on the PIN Pad display and return response code for remote diagnostic. Message element:   Request frame (HOST to PIN Pad) Field  Length Value and description <SI>  1  <0F> 07  2  Message ID [Master key] 16 Master Key used of encoding (hexadecimal string) [Clear text] 16 Clear text for encoding (hexadecimal string) [Cipher text] 16 Known ciphered text (hexadecimal string) <SO>  1  <0E> [LRC]  1  Checksum Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 07  2  Message ID [response code]  1  0: Test Success F: Test Failed. <SO>  1  <0E> [LRC]  1  Checksum Message flow: HOST Direction   PIN Pad Message 07 (request)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 07 (response) <ACK>/<NAK>/ <EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page25 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message 08 Select Master Key Format:   <SI>08[KeyID]<SO>[LRC] Message length: Fixed 6 bytes. Usage: This message is used to select one of the 10 possible PIN encrypting master keys previously loaded using message 02. The selected master key will be used in the following transactions.  Note: Check master key existence before change: This message does not respond for checking master key existence. You may choose an empty master key without notice.   TDES capability: If selected master key is a double length key (32 characters when loaded with message 02), PP190 will treat all session keys (in MK/SK message 70, Z60, Z62) as EDE encrypted by this master key. (See Appendix A)   Confirm key existence before issue 08: message 08 is not responsible for check if [KeyID] has a valid master key, use message 04 before 08.  Message element: Field  Length Value and description <SI>  1  <0F> 08  2  Message ID [KeyID]  1  0~9, one of Master key id. <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 08     <ACK>/<NAK>/<EOT>   [Success] <SI>080<SO> [Fail] <SI>08[errCode]<SO> <EOT>  Error Message: Error Code Meaning ‘1’  Key index > 9
PIN Pad 190 Programmer’s Manual   2014-02-06  Page26 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 09 Communication Test Format:   <SI>09<SO>[LRC] <SI>09<SUB>PROCESSING<SO>[LRC] Message length: Fixed 5 bytes for requesting message, fixed 16 bytes for response message. Usage: This message is used to test communication link between HOST and the PIN Pad. Both HOST and PIN Pad can initiate communication test. The initiating party should send the requesting message; the other party should response with the response message that should be ACKed if received correctly. After verifying that the response message is correctly, the initiating party should send back the same response message and the receiving party should acknowledge this message. Testing results are shown on the PIN Pad display. Message element:   Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 09  2  Message ID <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 09  2  Message ID <SUB>  1  <1A> [Test string] 10 ASCII string “PROCESSING” <SO>  1  <0E> [LRC]  1  Checksum  Result frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 09  2  Message ID [response code]  1  0: Test Success F: Test Failed. <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page27 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Message flow: HOST Direction   PIN Pad Message 09 (request)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 09 (response frame) <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 09 (response)     <ACK> (Good LRC) <NAK> (Bad LRC)   Message 09 (result frame) <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page28 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 11 PIN Pad Device Connection Test Format:   <SI>11<SO>[LRC] Message length: Fixed 5 bytes. Usage: This message is used to ensure that the PIN Pad is attached to the HOST working normally. PIN Pad will response an ACK (or NAK if LRC incorrect) within one second. Message element: Field  Length  Value and description <SI>  1  <0F> 11  2  Message ID <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad Message 11     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page29 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 13  Adjust COM1 Baud Rate (RS-232 version only) Format:   <SI>13[baud code][mode]<SO>[LRC] Message length: Variable, 6 bytes. Usage: This message will change the working baud rate and transmit mode of PP190 for later operations. The setting is kept in the  battery-powered  memory, which will not be erased until security is breached or the battery exhausted. Baud rate will be changed after message flow ends. Note: If [mode] parameter is not specified, the default transmit mode is N, 8, 1. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 13  2  Message ID [baud code]  1  ASCII character ‘1’ = 1200bps ‘2’ = 2400bps ‘3’ = 4800bps ‘4’ = 9600bps ‘5’ = 19200bps ‘6’ = 38400bps ‘7’ = 57600bps ‘8’ = 115200bps <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 13  2  Message ID [status]  1  ASCII character ‘0’ for success ‘1’ for parameter error <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad Message 13 (request) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page30 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 13 (response) <ACK>/<NAK>/<EOT>     <EOT>   (Change working baud rate and save setting) Message flow: HOST Direction PIN Pad Message 14 (Request frame)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 14 (Response frame) <ACK>/<NAK>/<EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page31 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 16 Remote self-test request Format:   <SI>16<SO>[LRC] Message length: Fixed 5 bytes. Usage: This message is used to ensure that the PP190 attached to the HOST is working normally. PP190 will response an ACK (or NAK if LRC incorrect) within one second. If multiple tests failed, response code will concatenate such as “<SI>1625<SO>”. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 16  2  Message ID <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 16  2  Message ID [Response]  1 .. 3 0 – Healthy 2 – System Core checksum fail 5 – Master keys CRC error <SO>  1  <0E> [LRC]  1  Checksum Message flow: HOST Direction PIN Pad Message 16 (Request frame)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 16 (Response frame) <ACK>/<NAK>/<EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page32 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 17  Request random number Format:   <SI>17<SO>[LRC] Message length: Fixed 5 bytes. Usage: This message is used to request PIN Pad to generate an 8bytes random number block. This random number is generated by hardware TRNG that is certified with sufficient security. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 17  2  Message ID <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 17  2  Message ID [RndBlk]  16 Random number block generated by PP190.   Format: hexadecimal string. <SO>  1  <0E> [LRC]  1  Checksum Message flow: HOST Direction PIN Pad Message 17 (Request frame)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 17 (Response frame) <ACK>/<NAK>/<EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page33 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 18 Get/Set PIN pad system time Format:   <SI>18<SO>[LRC] (Request frame to get system time) <SI>18[YYYY][MM][DD][HH][MM][SS]<SO>[LRC] (Request frame to set system time) Message length: Fixed 5 bytes or 19 bytes. Usage: This message is used to set real world time in PP190 and for EMV level 2 transaction log.   Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 18  2  Message ID [YYYY]  4  (optional, only set time need) AD year, i.e. “2006” [MM]  2  (optional, only set time need) Month, “01”~”12” [DD]  2  (optional, only set time need) Day of month, “01”~”31” [HH]  2  (optional, only set time need) Hour, “00”~”23” [MM]  2  (optional, only set time need) Minute, “00”~”59” [SS]  2  (optional, only set time need) Second, “00”~”59” <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page34 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 18  2  Message ID [status]  1  0: Success F: Failed. [YYYY]  4  (optional, only get time will response) AD year, i.e. “2006” [MM]  2  (optional, only get time will response) Month, “01”~”12” [DD]  2  (optional, only get time will response) Day of month, “01”~”31” [HH]  2  (optional, only get time will response) Hour, “00”~”23” [MM]  2  (optional, only get time will response) Minute, “00”~”59” [SS]  2  (optional, only get time will response) Second, “00”~”59” <SO>  1  <0E> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad Message 18 request frame     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 18 Response Frame <ACK> /<NAK> /<EOT>      Processing and send <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page35 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 19  Query Firmware Version Format:   <SI>19[part]<SO>[LRC] (request frame) <SI>19.[Version].[SubVer].[Chksum] <SO>[LRC] (response frame) Message length: Fixed 6 bytes (request frame) / 82 bytes (response frame). Usage: This message is used to query PP190 firmware version number and firmware check sum value. Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 19  2  Message ID [part]  1  Firmware Part number 1: System Core 2: Prompt Message <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 19  2  Message ID .  1  <2E>, field separator [Version]  8.  Firmware version (ASCII string) .  1  <2E>, field separator [SubVer] 2  Firmware sub version (‘0’~’9’) .  1  <2E>, field separator [chksum] 64 Firmware checksum (‘0’~’9,  ‘A’ ~’F’’) <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page36 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Message flow: HOST Direction PIN Pad Message 19 (Request frame)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 19 (Response frame) <ACK>/<NAK>/<EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page37 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 1J Turn ON/OFF LCD Backlight Format:   <SI>1J[option]<SO>[LRC] Message length: Fixed 6 bytes. Usage: This message can control the global backlight ON or OFF for the LCD of PP190 with backlight option. By default, PP190 will turn on its LCD backlight when it receives PIN entry or clear text entry message such as 70 or Z52, and turn it off when those functions exits. With message “1J1”,  the PP190 will keep LCD backlight turned ON until “1J0” is issued.  Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 1J  2  Message ID [option]  1  ASCII character ‘0’: Turn off LCD backlight ‘1’: Turn on LCD backlight <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 1J  2  Message ID [status]  1  ASCII character ‘0’: Turn off LCD backlight ‘1’: Turn on LCD backlight <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page38 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction   PIN Pad Message 1J     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 1J (Response frame) <ACK>/ <NAK>/ <EOT>     <EOT>     LCD backlight turned ON/OFF
PIN Pad 190 Programmer’s Manual   2014-02-06  Page39 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 1M Setup Keypad Beeper Format:   <SI>1M[option]<SO>[LRC] Message length: Fixed 6 bytes. Usage: This message is used to turn on or turn off beeper when the keypad is pressing.  Message element: Request frame (HOST to PIN Pad) Field  Length  Value and description <SI>  1  <0F> 1M  2  Message ID [option]  1  ASCII character ‘0’: Disable keypad beeper. ‘1’: Enable keypad beeper. <SO>  1  <0E> [LRC]  1  Checksum  Response frame (PIN Pad to HOST) Field  Length  Value and description <SI>  1  <0F> 1M  2  Message ID [status]  1  ASCII character ‘0’: Keypad beeper disabled. ‘1’: Keypad beeper enabled. <SO>  1  <0E> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page40 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction   PIN Pad Message 1M     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 1M (Response frame) <ACK>/ <NAK>/ <EOT>     <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page41 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Section 6    Online transaction messages with Master/Session Keys (MK/SK)   Message 70 PIN entry request (MK/SK) Format:   <STX>70.[Account]<FS>[session key][Amount] <FS>[timeout]<ETX>[LRC] Message length: Variable 36 to 51 bytes (max. 67 bytes for TDES session key). Usage: Display prompt and accept customer PIN input. The following prompt will be displayed:  "Total Amount"  "$xxx.xx"  "Enter PIN"  "Push "ENTER""  The PIN Pad will then wait till the PIN entered and [ENTER]  key is pressed. After ENTER key is pressed, the string “PIN PAD” and “PROCESSING” will be displayed until the CLEAR key is pressed. During this period, the PIN Pad will not process any message other than the CANCEL message (message 72).  NOTE: Aborting transaction: Press CLEAR button to reset the PIN input and CAN (cancel) button to abort the transaction. PIN length: According to ANSI X9.8 standard, the length of PIN should between 4 to 12 digits. If user inputs less than 4 digits and press ENTER, PP190 will beep for error and continue to wait for user’s input. When user inputs 13th character, PIN pad will beep for error, conserves PIN character 1st to 12th, and wait for ENTER. This message has DES Time Throttle: See Appendix A for details. Master key must be selected before transaction: PP190 will warn and refuse message 70 if message 08 was not issued before. Triple DES capability: Following table shows the logic of PP190 when processing single-length and double-length MK/SK. (TDES in EDE order, see Appendix A).  Session Key: If the selected key is with usage “P0”, the session key should be all zeros.  Session key Master key Double length Single length Double length PP190 TDES decrypts L-key and R-key of [session key] value, using active master key. PIN blocks are TDES encrypted by decrypted session key. PP190 TDES decrypts [session key] value, using active master key. PIN blocks are DES  encrypted by decrypted session key.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page42 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Single length PP190 DES decrypts L-key and R-key of [session key] value, using active master key. PIN blocks are TDES encrypted by session key. PP190 DES decrypts [session key] value, using active master key. PIN blocks are DES  encrypted by session key.   Message element:   Field  Length  Value and description <STX>  1  <02> 70  2  Message ID .  1  <2E>, delimiter [Account] 8..19 Card account number <FS>  1  <1C>, field separator [session key] 16 or 32 Working key encrypted using selected master key.  32-characters session key produces TDES encrypted PIN block with EDE order. Format: hexadecimal string. This filed should be all zeros if the selected key is with usage “P0” [Amount] 4..8 Amount of goods to be displayed on PIN Pad. <FS>  1  (optional) <1C>, field separator [timeout]  1  (optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page43 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction PIN Pad Message 70     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) Prompt user to enter PIN.   Message 71 or <EOT> when input timed out or user pressed [CAN] <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)       Display “PIN PAD PROCESSING”
PIN Pad 190 Programmer’s Manual   2014-02-06  Page44 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 71 Encrypted PIN Block Response Format:   <STX>71.<fkey flag><PIN length>01[PIN][LRC] (PIN block frame) <STX>71[error code]<ETX>[LRC] (Error code frame) Message length: Fixed 27 bytes for PIN block frame, 6 bytes for error code frame. Usage: Send the entered PIN to HOST in encrypted format. Message element:   Field  Length  Value and description <STX>  1  <02> 71  2  Message ID .  1  <2E> delimiter [Fkey flag]  1  Always  ‘0’  (This field is kept to retain old model compatibility.) [PIN length]  2  00, 04..12 length of PIN entered 01  2  01 format of PIN block, always 01 [PIN] 16  Encrypted PIN blocks Format: hexadecimal string. <ETX>  1  <03> [LRC]  1  Checksum  Message 71 (Error message) Field  Length  Value and description <STX>  1  <02> 71  2  Message ID [Error code]  1  Code to indicate error (see next page) <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page45 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST  Direction   PIN Pad Message 70/Z60/Z62     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 71 or <EOT> when input tined out or user pressed [CAN] <ACK> (Good echo) <NAK> (Bad LRC) (<EOT> after 3 NAKs)       Display processing prompt Error codes: Code Meaning '0' Null Account input field. '1'  Key value error. (Active master key not exist, or session key value conflicted with the usage of active master key, or session key length longer than active master key) '2' Account number shorter than 8 digits. '3' Account number longer than 19 digits. '4' Account number have character other than '0'-'9'. '5' Working key format error. '6' Timeout value error '7'  No more DES operation within 60 min. (see Appendix A) '8' From 70, Amount string format error. From Z62, PIN count, Accept Null PIN flag, and Prompt string format error. 'A'  Currently selected master key over range (Master key slot A to F will cause this error message because they are supposed to do authentication and MAC, not for PIN entry) 'B'  Flash memory read/write error 'C'  Memory buffer allocation error 'E'  Data length error in a field. 'G'  Specified file not found or authentication error. 'H'  Receive command 72.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page46 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages 'I'  Cancel key is press. 'J'  PIN entry timeout.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page47 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 72 PIN Entry Cancel Format:   <STX>72<ETX>[LRC] Message length: Fixed 5 bytes. Usage: Cancel current transaction and return the PIN Pad to IDLE state, used to interrupt command in process. If PP190 receives message 72 while processing user input such as swipe card or enter PIN, It will send <EOT> to acknowledge that operation is canceled. Message element:   Field  Length  Value and description <STX>  1  <02> 72  2  Message ID <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 72     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   <EOT> Optional. If PIN pad is waiting for user’s PIN input.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page48 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z0  Move Display Cursor Format:   <STX>Z0[XX][YY]<ETX>[LRC] Message length: Fixed 9 bytes. Usage: Move the display cursor.  Z0 message is enabled when PIN pad receives first Z2 message. Under Z2-authenticated mode, Z0 message is also disabled. Message element:   Field  Length  Value and description <STX>  1  <02> Z0  2  Message ID [XX]  2  X-coordinate, 01 ~ Max. Characters per line [YY]  2  Y-coordinate, 01 ~ Max. line <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message Z2      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string. Message Z0     <ACK>  /  <NAK>  / <EOT>       PIN pad moves cursor Message Z2 (without clear screen)     <ACK>  /  <NAK>  / <EOT>     Display 2nd string from the coordinate specified by Z0.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page49 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z1 Reset State Format:   <STX>Z1<ETX>[LRC] Message length: Fixed 5 bytes. Usage: Force the PIN Pad to enter IDLE state. Message element:   Field  Length  Value and description <STX>  1  <02> Z1  2  Message ID <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message Z1     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page50 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z2 Display String Format:   <STX>Z2<SUB>[string]<ETX>[LRC] (Request frame, normal) <STX>Z2<GS>[PromptID]<SUB><ETX>[LRC]  (Request frame, authenticated) <STX>Z2<RS>[PromptID]<SUB><ETX>[LRC]  (Request frame, authenticated for PIN entry) <STX>Z2[status]<ETX>[LRC]  (Response frame, authenticated) Message length: Variable, at least 6 bytes. Usage: PIN Pad to show the indicated prompt string on its display, until [CAN] key is pressed. If the first character of message is <GS> (0x1D) or <RS> (0x1E), PIN pad will treat following message string as ID number, and search its predefined message table for corresponding message string, then display the string on the screen. Note: 1. Two Z2 message with authenticated prompt ID can be issued in serial to form a longer sentence, or used in combination with normal string which contains only digits. 2. Z2 message with PIN entry prompt will force user issue every message with <SUB>, which implies the PIN entry message can’t be concatenated.   3. PIN pad will temporarily turn off timer display for the first Z2 message it received. After Z42, Z50, Z60 are performed, [CAN] key is pressed, or any other message received and processed, PIN pad will turn on the timer display. Message element:   Z2 request frame (normal mode) Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID <SUB>  1  <1A> (optional) When <SUB> exists, PIN pad will clear screen contents and hide pop window before display string. [string]  0 .. 32 ASCII string to be displayed <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page51 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Z2 request frame (authenticated mode with fixed prompt) Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID <GS>  1  <1D>, mark of authenticated frame with fixed prompt. Prompt ID  3 Prompt ID that corresponds to fixed prompt provided by PIN pad.   Decimal string: 001 ~ 999. <SUB>  1  <1A> (optional) When <SUB> exists, PIN pad will clear screen contents and hide pop window before display string <ETX>  1  <03> [LRC]  1  Checksum  Z2 request frame (PIN entry mode with fixed prompt) Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID <RS>  1  <1E>, mark of PIN entry frame with fixed prompt. Prompt ID  3 Prompt ID that corresponds to fixed PIN entry prompt provided by PIN pad.   Decimal string: 001 ~ 999. <SUB>  1  <1A>   PIN pad will clear clear screen contents and hide pop window before display string <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page52 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Z2 response frame (authenticated mode) Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID [status]  1  ‘0’: OK ‘1’: Prompt ID not supported. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Normal frame HOST Direction   PIN Pad Message Z2     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string  Authenticated frame HOST Direction   PIN Pad Message Z2     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z2  (response frame) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string <EOT> (if received <ACK>)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page53 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z3 Display Line Prompts Format:   <STX>Z3[count]<SUB>[prompt1]<FS>[prompt2..7]<ETX>[LRC] (Request frame, normal)  <STX>Z3<GS>[PromptID1]<FS>[PromptID2..7]<SUB><ETX>[LRC] (Request frame, authenticated) <STX>Z3<RS>[PromptID1]<FS>[PromptID2..7]<ETX>[LRC] (Request frame, authenticated for PIN entry) <STX>Z3[status] <ETX>[LRC]  (Response frame, authenticated) Message length: Variable 8 to 124 bytes. Usage: The PIN Pad will display the received prompt strings (up to 7 lines of prompt). If the length of prompt exceeds the maximum characters per line, this prompt will be truncated.  Message element: Z3 request frame (normal mode) Field  Length  Value and description <STX>  1  <02> Z3  2  Message ID [Count]  1  Number of prompts to be displayed <SUB>  1  <1A> (optional) When <SUB> exists, PIN pad will clear clear screen contents and hide pop window before display string [Prompt1] var First string to be displayed, max length is one line (20 or 40 characters depend on font size). <FS>  1  <1C>, field separator [Prompt2..7] var Remaining strings to be displayed.   Note. <FS> is required between   messages <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page54 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Z3 request frame (authenticated mode or PIN entry mode) Field  Length  Value and description <STX>  1  <02> Z3  2  Message ID <GS> or <RS>  1  <1D> for authenticated mode <1E> for PIN entry mode (In these mode, PIN Pad will clear screen contents and hide pop window before showing prompts.) [Prompt ID1]  3  Prompt ID that corresponds to fixed prompt provided by PIN pad. Decimal string: 001 ~ 999. <FS>  1  <1C>, field separator [Prompt ID2..7]  3  Prompt ID that corresponds to fixed prompt provided by PIN pad.   Decimal string: 001 ~ 999. Note. <FS> is required between   prompt ID. <ETX>  1  <03> [LRC]  1  Checksum   Z3 response frame (authenticated mode) Field  Length  Value and description <STX>  1  <02> Z3  2  Message ID [status]  1  ‘0’: OK ‘1’: Prompt ID not supported. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page55 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: Normal frame HOST Direction   PIN Pad Message Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display prompts as required  Authenticated frame HOST Direction   PIN Pad Message Z3      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z3  (response frame) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string <EOT> (if received <ACK>)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page56 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Z2 / Z3 Authenticated mode with fixed prompt To enable message Z42 and Z50, user has to issue Z2 / Z3 message with a prompt ID supported by PIN pad (See Appendix  C). These prompts are verified during Payment Card Industry (PCI) Security Conformance tests to make sure users will not expose sensitive information (such as PIN) accidentally.    For security reason, to issue authenticated frame of Z2 / Z3 at the first time, the <SUB> flag is mandatory. After Z2 authenticated mode entered, PIN pad will accept two kind of Z2 packet:   1. Z2 packet in normal mode, without <SUB> flag, and contains only digits (0~9) 2. Z2 packet in authenticated mode, without <SUB> flag. For example, issue Z2<GS>005<SUB> and Z2<GS>016 will show “PLEASE ENTER DRIVER LICENSE” on the screen.   Z2 / Z3 PIN entry mode with fixed prompt To enable Z60, user has to issue Z2 / Z3 message with a prompt ID supported by PIN pad, dedicated for PIN entry (See Appendix D). These prompts are verified during Payment Card Industry (PCI) Security Conformance tests to make sure users will not misunderstand PIN entry request as other non-sensitive data. Also message Z62’s prompt1 and prompt2 will be checked to see if they are listed in this prompt table. If not, PIN pad will reject Z62.  Any other messages other than Z2, Z3, Z42, Z50, and Z60 or any unsuccessful Z2 / Z3 messages (wrong prompt ID, format error, Z2 message includes non decimal characters) will make PIN pad to leave Z2 / Z3 authenticated mode to avoid attack.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page57 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z2 Display String with Authentication Code Format:   <STX>Z2<FS>[KeyID][MAC][Mode][string]<SUB><ETX>[LRC] (Request frame) <STX>Z2[status]<ETX>[LRC] (Response frame) Message length: Variable. Usage: This command allows acquirer to show free message on screen as prompt for clear text entry (Z42, Z50) and PIN entry (Z60). PP190 will verify MAC value by the following rule: * Collect [Mode] character, [string] (exclude white space, punctuation marks and digits), and <SUB> character (if exist), as byte array, padding with ASCII ‘0’ (0x30) to the multiple of 8. * Use the key specified by [KeyID] and ISO-9797-1 Algorithm 3 to generate message authentication code for above data. * Compare the leftmost 4 bytes of MAC value and the one written in the Z2 command. If MAC value matches, PP190 will display the [string] written in Z2 command.  Note: 1. If Z2 (string with MAC) is used in combination with Z2 (fixed prompt), their mode character (GS / RS) must be the same; Otherwise PIN pad will reject secondary Z2. 2. PIN pad will temporarily turn off timer display for the first Z2 message it received. After Z42, Z50, Z60 are performed, [CAN] key is pressed, or any other message received and processed, PIN pad will turn on the timer display.  3. If continuous Z2 (string with MAC) without <SUB> cause the string out of LCD display’s range, some character will be cut. Message element :   Z2 with MAC, request frame Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID <FS>  1  <1C>, field separator. [KeyID]  1  ‘B’ ~ ‘E’, key to verify MAC value. The specified key must have usage ‘M3’  and mode ‘V’.   [MAC]  8 Message authentication code of following message (including <SUB> if exist). [Mode]  1  <GS> (0x1D) for Non-PIN entry. <RS> (0x1E) for PIN entry. [string]  0 .. 32 ASCII string to be displayed <SUB>  1  <1A> (optional)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page58 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages When <SUB> exists,  PIN pad will clear screen contents and hide pop window before display string, and also reset entry mode. <ETX>  1  <03> [LRC]  1  Checksum  Z2 with MAC, response frame Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID [status]  1  ‘0’: OK ‘1’: MAC key ID error (out of ‘B’~’E’). ‘2’: MAC key attribute error. ‘3’: MAC value error. ‘4’: Packet format error. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message Z2     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z2  (response frame) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string <EOT> (if received <ACK>)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page59 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z3  Display Line Prompts with Authentication Code Format:   <STX>Z3<FS>[KeyID][MAC][count][Mode][prompt1]<FS> [prompt2..7]<SUB><ETX>[LRC] (Request frame) <STX>Z3[status]<ETX>[LRC] (Response frame) Message length: Variable. Usage: This command allows acquirer to show free message on screen as prompt for clear text entry (Z42, Z50) and PIN entry (Z60). PP190 will verify MAC value by the following rule: * Collect [Mode] character, [prompt_n] (exclude white space, punctuation marks and digits), and <SUB> character (if exist), as byte array, padding with ASCII ‘0’ (0x30) to the multiple of 8. * Use the key specified by [KeyID] and ISO-9797-1 Algorithm 3 to generate message authentication code for above data. * Compare the leftmost 4 bytes of MAC value and the one written in the Z2 command. If MAC value matches, PP190 will display the [string] written in Z2 command.  Note: 1. If Z3 (string with MAC) is used in combination with Z3 (fixed prompt), their mode character (GS / RS) must be the same; Otherwise PIN pad will reject secondary Z3. 2. PIN pad will temporarily turn off timer display for the first Z2 message it received. After Z42, Z50, Z60 are performed, [CAN] key is pressed, or any other message received and processed, PIN pad will turn on the timer display.  Message element:   Z2 with MAC, request frame Field  Length  Value and description <STX>  1  <02> Z3  2  Message ID <FS>  1  <1C>, field separator. [KeyID]  1  ‘B’ ~ ‘E’, key to verify MAC value. The specified key must have usage ‘M3’  and mode ‘V’.   [MAC]  8  Message authentication code of following message (including <SUB> if exist). [count]  1  ‘1’ ~ ‘7’, number of following prompts. [Mode]  1  <GS> (0x1D) for Non-PIN entry. <RS> (0x1E) for PIN entry. [prompt1]  Var. First string to be displayed, max length is one line (20 or 40 characters depend on
PIN Pad 190 Programmer’s Manual   2014-02-06  Page60 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages font size). <FS>  1  <1C>, field separator [prompt N]  Var. Second to end string to be displayed. Each prompt is separated by <FS>. <SUB>  1  <1A> (optional) When <SUB> exists,  PIN pad will clear clear screen contents and hide pop window before display string <ETX>  1  <03> [LRC]  1  Checksum  Z3 with MAC, response frame Field  Length  Value and description <STX>  1  <02> Z2  2  Message ID [status]  1  ‘0’: OK ‘1’: MAC key ID error (out of ‘B’~’E’). ‘2’: MAC key attribute error. ‘3’: MAC value error. ‘4’: Packet format error. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message Z3      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z3  (response frame) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display string <EOT> (if received <ACK>)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page61 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Example to use Z2 / Z3 with Authencation Code. [Example 1] 1. Use message 02 (ANSI TR31 frame) to load following key to position ‘B’: BCDE90123456789ABCDE90123456789A, Usage = M3, Mode = V. 2. Assume we want to clear screen and display following string for PIN entry: “AMOUNT 123456.78 ENTER YOUR PIN”. 3. The data for MAC generation (‘A’ to ‘Z’, ‘a’ to ‘z’ and ISO8859-15 high page character from 0xBC to 0xFF, padded with ASCII 0): <RS>AMOUNTENTERYOURPIN<SUB>0000    1E414D4F554E54454E544552594F555250494E1A30303030 The white spaces and digits are not counted into MAC, this feature enables acquirer to issue PIN entry prompts with different amount, but keep the same MAC value. 4. Use the key specified in the step 1 to calculate ISO9797-1 algorithm 3 MAC. The result is: C51401D727D761E2.   Take leftmost 4 bytes as MAC value: C51401D7. 5. Send  <02>Z2<1C>BC51401D7<1E>AMOUNT 123456.78 ENTER YOUR  PIN<1A><03> to PIN Pad, Then message Z60 can be issued to request PIN entry. 6. Send <02>Z2<1C>BC51401D7 <1A>AMOUNT 123.45 ENTER YOUR PIN<03> to PIN Pad to see the same MAC applies to different amounts.  [Example 2] 1. Use message 02 (ANSI TR31 frame) to load following key to position ‘B’: 6AC292FAA1315B4D8234B3A3D7D5933A, Usage = M3, Mode = V. 2. Assume we want to clear screen and display for non-PIN entry: “MESSAGE ONE 1.0”  and “MESSAGE TWO 2.0”. 3. The data for MAC generation (padded with ASCII 0): <GS>MESSAGEONE<FS>MESSAGETWO<SUB>0  1D4D4553534147454F4E451C4D45535341474554574F1A30 4. Use the key specified in the step 1 to calculate ISO9797-1 algorithm 3 MAC. Take leftmost 4 bytes as MAC value: 22C0BAD9. 5. Send <02>Z3<1C>B22C0BAD92<1D>MESSAGE ONE 1.0<1C>MESSAGE TWO 2.0<1A><03> to PIN pad.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page62 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z42   Read Key Code Format:   <STX>Z42[timeout]<ETX>[LRC] Message length: Variable 6 to 9 bytes. Usage: Once PP190 receives this command, it begins polling functional key array until timeout.   If  PP190 received Z2 / Z3 authenticated frame before Z42, it will return any key pressed by user by ASCII key codes via message Z43. Else it will return only function key codes (F1, F2, F3, F4, CAN, CLR, ENTER), and reject numerical key (0 to 9). Multiple key press or combined key press will be discarded. Abort input: Issue message 72 to abort the operation. Note: Z2/Z3 required: Because Z42 will not show any message to prompt user operation, Z2 or Z3 should be issued before this command, or   PIN pad will send <EOT> and stop.    Message element:   Field  Length  Value and description <STX>  1  <02> Z42  3  Message ID [timeout] 1 to 3 ASCII character from 1 to 255, for example “10” means 10 seconds timeout. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PP190 Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show prompt message Message Z42      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z43 <ACK>/<NAK>/<EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page63 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z43   Read Key Code Response Format:   <STX>Z43[Keycode]<ETX>[LRC] Message length: Fixed 7 bytes. Usage: This is the response frame of Z42. Message element:   Field  Length  Value and description <STX>  1  <02> Z43  3  Message ID [keycode]  1  ‘0’ to ‘9’   ASCII ‘A’ to ‘C’ denotes 3 function keys.   ‘A’ = [F1] ‘B’ = [F2] ‘C’ = [F3] ‘D’ = [F4] ‘*’ = [CAN] ‘#’ = [ENTER] ‘/’ = [CLR] ‘?’ means time out. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: (Please refer to message Z42)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page64 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z50   String Entry Request Format:   <STX>Z50[echo flag][timeout][max entry]<ETX>[LRC] Message length: Variable 10 to 12 bytes. Usage: Request user to input string on keypad. Then PP190 will wait for keypad input and store ASCII data into internal buffer. To input English character on the keypad, press [F2] key to rotate the last character. For example, press [1], [F2], [F2] will input a ‘Z’  character into PP190. The maximum length of internal buffer is 32 characters. User can use [CLR] to clear input buffer and input again, or [CAN] to cancel input. Press ‘0’ and press [F2] will transform ‘0’ into period or white space.  Abort input: Issue message 72 to abort the operation. Note: A Z2 or Z3 message with authenticated frame must be issued before Z50. Otherwise PIN pad will refuse to execute. Message element:   Field  Length  Value and description <STX>  1  <02> Z50  3  Message ID [echo flag]  1  ‘0’: echo input as ‘*’ ‘1’: echo input as is ‘2’: do not echo [timeout]  3  ASCII character from 1 to 255 to set the timeout for each keypress, for example “010” means 10 seconds timeout after the last keypress. [max entry] 1 or 2 (optional) Maximum entry count.   Range from 00 to 32 (or 0 to 32) <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page65 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction   PP190 Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show prompt message Message Z50     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z51 (or <EOT> when input cancelled) <ACK>/<NAK>/<EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page66 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z51   String Entry Response Format:   <STX>Z51[string]<ETX>[LRC] Message length: Variable, maximum 55 bytes. Usage: This is the response frame of Z50 and ZG. Message element:   Field  Length  Value and description <STX>  1  <02> Z51  3  Message ID [string]  1..32 User inputted string. ‘?’ means time out. ‘!’ means file not found or authentication error. (For Message ZG error response) ‘%’ means prompt ID not supported. (For Message ZG error response) <ETX>  1  <03> [LRC]  1  Checksum  Message flow: (Please refer to message Z50)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page67 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z60   PIN entry request with external prompt (MK/SK) Format:   <STX>Z60.[account]<FS>[session key]<FS>[timeout]<ETX>[LRC] Message length: Variable 32 to 43 bytes (max. 59 bytes for TDES session key). Usage: Request the PIN Pad to accept customer PIN entry and encrypt it using the account number and working key sent along in this message. The encrypted PIN block should be retrieved via message 71.  Note: Z2/Z3 (PIN entry mode) required: Message Z2 or Z3 (PIN entry mode) should be issued before this command, or PIN pad will send <EOT> and stop. Aborting Transaction: Please refer to message 70. PIN length: Please refer to message 70. Master key must be selected before transaction: Please refer to message 70. Triple DES capability: Please refer to message 70.  Session Key: If the selected key is with usage “P0”, the session key should be all zeros.  Message element:   Field  Length  Value and description <STX>  1  <02> Z60  3  Message ID .  1  <2E>, delimiter [Account] 8 .. 19 Account number <FS>  1  <1C>, Field separator [Session key] 16 or 32 Session key encrypted with selected master key.  32-characters session key produces TDES encrypted PIN block with EDE order. Format: hexadecimal string. This filed should be all zeros if the selected key is with usage “P0” <FS>  1  (Optional) <1C>, Field separator [timeout]  1  (Optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page68 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction    PIN Pad Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show prompt message Message Z60     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 71 (after customer PIN entered), or <EOT> when input timed out or user pressed [CAN] <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page69 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z62   PIN entry request with customized prompt (MK/SK) Format:   <STX>Z62.[account]<FS>[session key][minPIN][maxPIN] [null flag][prompt1]<FS>[prompt2]<FS>[proc prompt]<FS> [timeout]<ETX>[LRC] Message length: Variable 39 to 100 bytes (max. 116 bytes for TDES session key). Usage: Request the PIN Pad to display the prompt message in this data frame, accept customer PIN entry and encrypt it using the account number and working key sent along in this message. Display the [proc prompt] when the PIN has been entered. The encrypted PIN block should be retrieved via message 71.  NOTE:   Aborting Transaction: Please refer to message 70. PIN length: Although Z62 allow programmer to specify the maximum and minimum PIN length, but it is not allowed to set the value of [maxPIN] and [minPIN] to exceed ANSI x9.8 specification except allow null PIN. Master key must be selected before transaction: Please refer to message 70. Triple DES capability: Please refer to message 70. Session Key: If the selected key is with usage “P0”, the session key should be all zeros.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page70 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message element: Field  Length  Value and description <STX>  1  <02> Z62  3  Message ID .  1  <2E>, delimiter [account] 8 .. 19 Account number <FS>  1  <1C>, field separator [session key] 16 or 32 Session key encrypted with selected master key. 32-characters session key produces TDES encrypted PIN block with EDE order. Format: hexadecimal string. This filed should be all zeros if the selected key is with usage “P0” [minPIN]  2  00, 04 .. 12 minimum PIN length. ('00' only available when [null flag] set to 'Y'). [maxPIN]  2  00, 04 .. 12 maximum PIN length. ('00' only available when [null flag] set to 'Y'). [null flag]  1  Y Null PIN allowed N Null PIN not allowed [prompt1]  1 .. 16  Prompt displayed before any key is pressed, alternate with prompt2 <FS>  1  <1C>, field separator  [prompt2]  1…16  Prompt displayed before any key is pressed, alternate with prompt1 <FS>  1  <1C>, field separator [proc prompt]  1…16  Prompt displayed after PIN is entered <FS>  1  (optional) <1C>, field separator [timeout]  1  (optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page71 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction    PIN Pad Message Z62     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   (Display [prompt1] and [prompt2] wait for user enter PIN)   Message 71 (after customer PIN entered) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)  (Display [proc prompt])
PIN Pad 190 Programmer’s Manual   2014-02-06  Page72 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z64   Query Key Check Value (KCV) Format:   <STX>Z64[KeyId]<ETX>[LRC] Message length: Fixed 7 bytes. Usage: This message will export the KCV of specified master key. KCV is calculated as following: 1. Use [KeyID] specified key as encryption key. 2. Use "0000000000000000" (8 bytes zero) as data. 3. If the encrypt key is single length (8 bytes), use DES algorithm to encrypt the data, else, use TDES algorithm to encrypt the data. 4. Take leftmost 3 bytes as KCV, output KCV as message Z65. Example: TDES key "0123456789ABCDEF FEDCBA9876543210" will have KCV as "08D7B4".  Message element: Field  Length  Value and description <STX>  1  <02> Z64  3  Message ID [KeyID]  1  ‘0’ ~ ‘9’, ‘A’ ~ ‘G’, The ID of master keys <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message Z64     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z65 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page73 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z65 Key Check Value Response Format:   <STX>Z65[KeyId][KCV]<ETX>[LRC] Message length: Variable. 13 bytes for KCV, or 8 bytes for error code. Usage:    This message is the response of Z64. If [KeyID] specified in Z64 is pointing to a valid master key, the KCV will be sent. Otherwise a question mark '?' will be sent.  Message element: Field  Length  Value and description <STX>  1  <02> Z65  3  Message ID [KeyID]  1  ‘0’ ~ ‘9’, ‘A’ ~ ‘G’, The ID of master keys [KCV] 6 or 1 Success: 6 characters KCV. Fail: '?'. <ETX>  1  <03> [LRC]  1  Checksum  Message flow:     Refer to message Z64.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page74 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z66   Message Authentication Code (MAC) Request Format:   <STX>Z66[PktType][SeqNo][KeyId] <FS> [SessionKey] <FS> [SecKeyId] <FS> [Message] <ETX> [LRC] Message length: Variable 14 to 270 bytes. Usage: This message is used to generate MAC codes according to algorithm specified in ANSI X9.19 (ISO 9797-1). User can send ASCII strings or hexadecimal strings to PP190 by Z66 message to generate its MAC. User can also separate a long message into multiple Z66 messages with increasing sequence number to generate a MAC.  NOTE: Message Length: Onetime message can be up to 224 characters (equal to 112bytes when send as hexadecimal string because 2 characters represents 1 bytes). Multiple messages can have sequence number from 00 to 99, thus the maximum capacity of Z66 message is 22400 characters (or 11200 bytes in binary mode). Multiple messages: When using multiple messages, [KeyId] and [SessionKey] and [SecKeyId] must be the same. [Message] must be the multiple of 8 characters (or 16 characters in binary mode). Or PP190 will generate a wrong MAC. MAC algorithm: PP190 generate TDES MAC according to ISO9797-1 algorithm 3. (Padding with 0. Initial vector = 0. Refer to Appendix A point 10 for detail algoritgm.)  Session Key: The value of session key relates to the usage of specified master keys. Usage of 1st Key ID Usage of 2nd Key ID Value of session key MAC Key “K0”  N/A Non-zero Session key “M3” (mode G) N/A Zero Master key specified by [KeyId]. If specified key is mode ‘V’, this is for MAC verification and cannot used to generate MAC for Z66 command. “M1” (mode G) “M1”  Zero Master key specified by [KeyId] as left key, and master key specified by [SecKeyId] as right key.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page75 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message element: Field  Length  Value and description <STX>  1  <02> Z66  3  Message ID [PktType]  1  '4' = ASCII last or only packet. '5' = ASCII first or middle of multiple packets. '6' = Binary last or only packet. '7' = Binary first or middle of multiple packets. [SeqNo]  2  '00' to '99', for onetime only packet, set to 00. [KeyId]  1  (Optional) Master key to use, range = 'B' to 'E'. If this filed is blank, the MAC master key will be the selected key 0 ~ 9. <FS>  1  <1C>, field separator [SessionKey] 32 Session key will be decrypted by: Master key pointed by [KeyId]. Format: hexadecimal string. This filed should be all zeros if the selected key is with usage “M1” or “M3” <FS>  1  <1C>, field separator [SecKeyId]  1  (Optional) Refer to note of Z66 usage. If first [KeyId] points to key with “K0”  or  “M3” usage, this field should be omitted. <FS>  1  <1C>, field separator [Message]  1-224 ASCII string or Hexadecimal string to be MACed. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: (Onetime only packets) HOST Direction    PIN Pad Message Z66 (type 4,6)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z67 (with MAC) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page76 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: (Multiple packets) HOST Direction    PIN Pad Message Z66 (Seq'00' and type 5,7)     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message Z67 (with status code '1') <ACK>  /  <NAK>  / <EOT>   Message Z66 (Seq'01'--'98', type 5,7)     <ACK> / <NAK> / <EOT>   Message Z67 (with status code '1') …………………  ……..  ………………………………….. Message Z66 (Sequence# larger than last packet, type 4,6)     <ACK> / <NAK> / <EOT>   Message Z67 (with MAC) <ACK>  /  <NAK>  / <EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page77 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z67   Message Authentication Code (MAC) Response Format:   <STX>Z67[status][MAC]<ETX>[LRC] Message length: Fixed 7 (status only) or 23 (with MAC) bytes. Usage: PP190 generated MAC calculation response. It contains status codes or MAC. Message element:   Field  Length  Value and description <STX>  1  <02> Z67  3  Message ID [status]  1  '0'=Success, MAC follows '1'=Ready for next Z66 packet, user in multiple messages. '2'=Sequence numbers out of order '3'=Master key specified in [KeyId] not exist, or range unacceptable (id 0 to A), or usage not “K0”, “M1”, “M3. '4'=Master key specified in [SecKeyId] unreasonable or not exist.   The [SecKeyId] only exists if [KeyId] points to a “M1” master key, and the [SecKeyId] itself should have “M1” usage. '5'=[Message] length have error (too long, zero length, or not even number in binary mode) '6'=[PkyType] flag has invalid value '7'=[Message] contents error (i.e. characters larger than 'F' in binary mode) '8'=[SessionKey] invaild ‘9’=MAC master key length should not be 8 ‘A’=Session key is incompatible to the usage of specified master key. (If MK’s usage is “M1”  or  “M3”, SK should contains all zero, if MK’s usage is “K0”, SK should not be zero.) [MAC] 16 Calculated MAC. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page78 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Message flow: (Please refer to message Z66)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page79 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z7 Turn ON/OFF CANCEL Message Display Format:   <STX>Z7[option]<ETX>[LRC] Message length: Fixed 6 bytes. Usage: When a CANCEL message received or a CANCEL key pressed to cancel a current transaction, the PIN Pad will display a “CANCEL REQUESTED” message. This could be turned ON or OFF using message Z7. Message element:   Field  Length  Value and description <STX>  1  <02> Z7  2  Message ID [option]  1  0 CANCEL REQUESTED displayed 1 CANCEL REQUESTED not displayed <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message Z7     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   CANCEL REQUEST prompt turned ON/OFF
PIN Pad 190 Programmer’s Manual   2014-02-06  Page80 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z8 Set Idle Prompt Format:   <STX>Z8[prompt]<ETX>[LRC] Message length: Variable 6 to 21 bytes. Usage: The   PIN Pad will display an idle prompt when it is in IDLE state. HOST can change this idle prompt via message Z8. If the prompt field is filled with a null string, then the   PIN Pad will use the default prompt afterwards. Message element:   Field  Length  Value and description <STX>  1  <02> Z8  2  Message ID [Prompt]  1 .. 16  Idle prompt to be used <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message Z8     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Displays idle prompt
PIN Pad 190 Programmer’s Manual   2014-02-06  Page81 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Section 7    Online transaction messages with Derived Unique Key per Transaction (DUKPT) The following messages are designed  for  Derived Unique Key Per Transaction (DUKPT) key management scheme described in ANSI X9.24-1992 and 2002 (Triple-DES DUKPT).   Note that some of the messages have the same IDs as those in MK/SK scheme, but with different message format. [TDES Capability] If PP190 receives double length key in message 90/94 (Load Initial Key), the following DUKPT operation will be done in TDES mode. PIN block will be TDES encrypted by derived key in EDE order. [Secondary DUKPT Key Set] PP190 provides 2nd key set of DUKPT operation for scalability. For example, customer can inject a DES initial key into key set 0 and a TDES initial key into key set 1, using key set 0 to process traditional DES transactions at first. When host systems ready to shift to TDES transaction, simply issue key set selection command (96) to make PP190 switch to key set 1 without recall all PP190 to inject new initial keys.    The following messages fall into this category:  60 Pre-Authorization PIN Entry Request  62 Pre-Authorization Amount Authorization Request  63 Pre-Authorization Amount Authorization Response  70 PIN entry request 78 PIN entry request via GUI  71 Encrypted PIN block response  72 PIN entry cancel  Z60 PIN entry request with external prompt (DUKPT)  Z62 PIN entry request with customized prompt  76 PIN Entry Test Request  90 Load First Initial Key Request  91 Load Initial Key Response  94  Load Second Initial Key Request  96  Select Active Key Set
PIN Pad 190 Programmer’s Manual   2014-02-06  Page82 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 60 Pre-authorization PIN Entry Request Format:   <STX>60[account] <ETX>[LRC] Message length: Variable 13 to 24 bytes. Usage: PIN pad will wait till the PIN entered and ENTER key is pressed. After PIN is entered, message 71 with PIN block will be sent as response. The HOST must transmit message 62 to ask for confirmation on transaction amount.  Note: Z2/Z3 (PIN entry mode) required: Message Z2 or Z3 (PIN entry mode) should be issued before this command, or PIN pad will send <EOT> and stop. Aborting Transaction: Please refer to message 70(DUKPT). PIN length: Please refer to message 70(DUKPT).     Message element:   Field  Length  Value and description <STX>  1  <02> 60  2  Message ID [Account] 8..19 Primary account number <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page83 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction    PIN Pad Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show Prompt Messages Message 60     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   (User enter PIN and press ENTER) Message 71 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display  “PIN PAD PROCESSING” until CLEAR pressed or another message received. Message 62     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   (User confirm the amount) Message 63 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)  
PIN Pad 190 Programmer’s Manual   2014-02-06  Page84 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 62 Pre-authorization Amount Authorization Request Format:   <STX>62[DC Ind][amount]<ETX>[LRC] Message length: Variable 10 to 14 bytes. Usage: Display prompt and accept customer PIN input. The following prompt will be displayed:  “Total Amount $xxx.xx” “Enter – Confirm” ”Cancel – Decline”  xxx.x is the content of Amount field, with length between 4 to 8 positions. The PIN Pad will then wait till either CAN or ENTER key is pressed. If ENTER key is pressed, the PIN PAD will response with positive confirmation. If CAN is pressed, the PIN PAD will response a negative confirmation. During this period, the PIN Pad will not process any message other than the message 72(cancel transaction). Message element:   Field  Length  Value and description <STX>  1  <02> 62  2  Message ID [DC Ind]  1  D/C: Debit/Credit Indicator [amount]  4..8  Amount of goods to be displayed on PIN Pad. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please reference message 60.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page85 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 70 PIN Entry Request (DUKPT) Format:   <STX>70[account]<FS>[DC Ind][amount]<FS>[timeout]<ETX>[LRC] Message length: Variable 21 to 36 bytes. Usage: Display prompt and accept customer PIN input. The following prompt will be displayed:  "Total Amount"  "$xxx.xx"  "Enter PIN"  "Push "ENTER""  xxx.x is the content of Amount field, with length between 4 to 8 positions. The PIN Pad will then wait till the PIN entered and [ENTER] key is pressed. After ENTER key is pressed, the string “PIN PAD” and “PROCESSING” will be displayed until the CLEAR key is pressed. During this period, the PIN Pad will not process any message other than the CANCEL message (message 72). NOTE: Aborting transaction: Press CLEAR button to reset the PIN input and CAN (cancel) button to abort the transaction. PIN length: According to ANSI X9.8 standard, the length of PIN should between 4 to 12 digits. If user inputs less than 4 digits and press ENTER,  PIN pad will beep for error and continue to wait for user’s input. When user inputs 13th character,  PIN pad will beep for error, conserves PIN character 1st to 12th, and wait for ENTER. Triple DES capability: If preloaded initial key is double length key, PP190 will produce TDES encrypted PIN block (EDE order).    Message element:   Field  Length  Value and description <STX>  1  <02> 70  2  Message ID [Account] 8..19 Primary account number <FS>  1  <1C>, field separator [DC Ind]  1  D/C: Debit/Credit Indicator [Amount]  4..8  Amount of goods to be displayed on PIN Pad. <FS>  1  (optional) <1C>, field separator [timeout]  1  (optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum  Message flow:
PIN Pad 190 Programmer’s Manual   2014-02-06  Page86 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages HOST Direction    PIN Pad Message 70     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 71 or   <EOT> when [CAN] pressed or input timed out. <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Display  “PIN PAD PROCESSING” until CLEAR pressed or another message received.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page87 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 71 Encrypted PIN Block Response Format:   <STX>71<fkey flag>[Key Serial#][PIN][LRC] (PIN block frame) <STX>71[error code]<ETX>[LRC] (Error code frame) Message length: Variable 32 to 42 bytes. Usage: Send the entered PIN to HOST in encrypted format. Message element: Field  Length  Value and description <STX>  1  <02> 71  2  Message ID [fkey flag]  1  Always  ‘0’ (This field is kept to retain old model compatibility.) [Key Serial#] 10..20 Key Serial number used in encrypting PIN. Included only when PIN is entered. Format: hexadecimal string. [PIN] 16  Encrypted PIN block Format: hexadecimal string. <ETX>  1  <03> [LRC]  1  Checksum  Message flow:   Please refer to message70 (DUKPT). Error codes: Code Meaning ‘0’ Null Account input field. ‘2’ Account number shorter than 8 digits. ‘3’ Account number longer than 19 digits. ‘4’ Account number have character other than ‘0’-‘9’. ‘5’ [D/C ind] field not exist or format error. ‘6’  Timeout value error. '8' Amount string format error. ‘A’ No DUKPT key injected. ‘B’ Flash read/write error. ‘C’ Memory buffer allocation error. ‘F’ DUKPT operation limit (1 million) reached, program stop. ‘G’  Specified file not found or authentication error.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page88 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages 'H'  Receive command 72. 'I'  Cancel key is press. 'J'  PIN entry timeout.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page89 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 72 PIN Entry Cancel Format:   <STX>72<ETX>[LRC] Message length: Fixed 5 bytes. Usage:  Cancel current transaction and return the PIN Pad to IDLE state, used to interrupt command in process. If   PIN Pad receives message 72 while processing user input such as signing, swipe card, enter PIN or key-in data, It will respond with <EOT> to acknowledge that operation is canceled.  Message element: Field  Length  Value and description <STX>  1  <02> 72  2  Message ID <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction    PIN Pad Message 72     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   <EOT> Optional. If  PIN pad is waiting for user’s input.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page90 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z60   PIN entry request with external prompt (DUKPT) Format:   <STX>Z60.[account]<FS>[timeout]<ETX>[LRC] Message length: Variable 15 to 28 bytes. Usage: Request the PIN Pad to accept customer PIN entry and encrypt it using the account number and working key sent along in this message. The encrypted PIN block should be retrieved via message 71.  Note: Z2/Z3 (PIN entry mode) required: Message Z2 or Z3 (PIN entry mode) should be issued before this command, or PIN pad will send <EOT> and stop. Aborting Transaction: Please refer to message 70. PIN length: Please refer to message 70. Triple DES capability: Please refer to message 70.  Message element:   Field  Length  Value and description <STX>  1  <02> Z60  3  Message ID .  1  <2E>, delimiter [Account] 8 .. 19 Account number <FS>  1  (Optional) <1C>, Field separator [timeout]  1  (Optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page91 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction    PIN Pad Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show prompt message Message Z60     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 71 (after customer PIN entered), or <EOT> when input timed out or user pressed [CAN] <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page92 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message Z62   PIN entry request with customized prompt (DUKPT) Format:   <STX>Z62.[account]<FS>[minPIN][maxPIN][null flag] [prompt1]<FS>[prompt2]<FS>[proc prompt]<FS>[timeout]<ETX>[LRC] Message length: Variable 39 to 100 bytes. Usage: Request the  PIN Pad to display the prompt message in this data frame, accept customer PIN entry and encrypt it using the account number and working key sent along in this message. Display the [proc prompt] when the PIN has been entered. The encrypted PIN block should be retrieved via message 71.  NOTE: Aborting Transaction: Please refer to message 70. PIN length: Although Z62 allow programmer to specify the maximum and minimum PIN length, but it is not allowed to set the value of [maxPIN] and [minPIN] to exceed ANSI x9.8 specification except allow null PIN. Triple DES capability: Please refer to message 70.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page93 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message element: Field  Length  Value and description <STX>  1  <02> Z62  3  Message ID .  1  <2E>, delimiter [account] 8 .. 19 Account number <FS>  1  <1C>, field separator [minPIN]  2  00, 04 .. 12 minimum PIN length. ('00' only available when [null flag] set to 'Y'). [maxPIN]  2  00, 04 .. 12 maximum PIN length. ('00' only available when [null flag] set to 'Y'). [null flag]  1  Y Null PIN allowed N Null PIN not allowed [prompt1]  1 .. 16  Prompt displayed before any key is pressed, alternate with prompt2 <FS>  1  <1C>, field separator  [prompt2]  1…16  Prompt displayed before any key is pressed, alternate with prompt1 <FS>  1  <1C>, field separator [proc prompt]  1…16  Prompt displayed after PIN is entered <FS>  1  (optional) <1C>, field separator [timeout]  1  (optional) ASCII character from ‘1’ to ‘9’ which is the timeout value in the unit of 30 seconds. Default = 9x30 = 270 seconds. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page94 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message flow: HOST Direction    PIN Pad Message Z2 or Z3     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)     Show prompt message Message Z62     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   (Display [prompt1] and [prompt2] wait for user enter PIN)   Message 71 (after customer PIN entered) <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)  (Display [proc prompt])
PIN Pad 190 Programmer’s Manual   2014-02-06  Page95 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 76 PIN Entry Test Request Format:   <STX>76[account]<FS>[DC Ind][amount]<ETX>[LRC] Message length: Variable 19 to 34 bytes. Usage: This message is designed to do DUKPT continuous PIN entry test. PP190 will send message71 assuming a PIN of ‘1234’.  Message element:   Field  Length  Value and description <STX>  1  <02> 76  2  Message ID [Account] 8..19 Primary account number <FS>  1  <1C>, field separator [DC Ind]  1  D/C: Debit/Credit Indicator [Amount]  4..8  Amount of goods to be displayed on PIN Pad. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: This message is identical to message70 except that a PIN of ‘1234’ is used instead of getting keypad input.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page96 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 7A  KSN output format Format:   <STX>7A[KSN_format] <ETX>[LRC] Message length: Fixed 6 bytes. Usage: This message will set the key serial number (KSN) format of message 71 (DUKPT frame). Format 0 is the original mode (strip leading ‘F’ of KSN) which is compatible of PP690, PP790SE and PP795, Format 1 is full mode (output full 20 characters of KSN).  Message element:   Field  Length  Value and description <STX>  1  <02> 7A  2  Message ID [KSN_format]  1  ‘0’: message 71 output KSN without leading ‘F’ ‘1’: message 71 output KSN with leading ‘F’. <ETX>  1  <03> [LRC]  1  Checksum  Message flow:   HOST Direction    PIN Pad Message 7A      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page97 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 90 Load First Initial Key Request Format:   <STX>90[IPEK][KSN]<ETX>[LRC] (Clear Text) <STX>90[TR-31 Key Block]<ETX>[LRC] (Encrypted) Message length: Fixed 41 or 57 bytes for clear text format, 93 or 109 bytes for TR-31 format. Usage: Load first set of DUKPT initial key and serial number key to PP190. Consequent keys will be generated using provided data.   If 32-characters (double length) initial key being loaded, PP190 will do key generation, PIN entry, and other DUKPT operations in TDES manner.  PP190 implements multiple security measures to conform Payment Card Industry (PCI) security requirement. In order to load clear text IPEK key, two authorized people with their password are required. Otherwise the user must issue message 90 with encrypted key value (ANSI TR31 format). See “Symmetric Keys Loading Authentication” for detailed information.  Note: VISA required key serial number format are as follows: 4’F’ characters, a 6-digit keyset identifier, 5-digit device ID, followed by a ‘0’,   i.e. “FF FF kk kk kk dd dd d0 00 00”  Message element: (Clear text format) Field  Length  Value and description <STX>  1  <02> 90  2  Message ID [IPEK]  16 or 32 Initial PIN encryption key. 32-characters Initial key will make PP190 act in TDES DUKPT mode. Format: hexadecimal string. [KSN]  20 Key serial number used in generating consequent keys. Format: hexadecimal string. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page98 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages (Encrypted format) Field  Length  Value and description <STX>  1  <02> 90  2  Message ID [TR-31 Key Block] 88 or 104 TR-31 key block with optional header block that contains KSN. See Appendix A for detail. <ETX>  1  <03> [LRC]  1  Checksum   Message flow: HOST Direction    PIN Pad Message 90     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 91 <ACK>/<NAK>/<EOT>    Example:   Clear Text IPEK key to be loaded:    ABCDEF0123456789FEDCBA9876543210 KSN:        FFFF9876543210E00000 The resulting 90 message :  <STX>90ABCDEF0123456789FEDCBA9876543210FFFF9876543210E00000<ETX>[LRC] TR-31 Key Block Key Block Protecting Key:    AA55AA55AA55AA55 3434343434343434 IPEK key to be loaded:    ABCDEF0123456789 FEDCBA9876543210 KSN:        FFFF9876543210E00000 Key Block Header:   B0104B1TX00N0100 KS18FFFF9876543210E00000 Padded IPEK:        0080 ABCDEF0123456789 FEDCBA9876543210 30111D18CC4C Derived KBEK:        3C50E1B7962F2171DC8643F1D923ABF7 Derived KBMK:        46FBEEB64EAE26A650952DA4F6DD8325 CMAC of (KBH + Padded key data), using KBMK: 93C3D5EBC6C407E4 Use CMAC as IV to do TDES CBC encryption on padded key data, using KBEK: Encrypted key data:   EC86E6E3B24544F97C629FB0E0586A0285D35BA78E9B13FB Result: <02>90B0104B1TX00N0100KS18FFFF9876543210E00000EC86E6E3B24544F9 7C629FB0E0586A0285D35BA78E9B13FB93C3D5EBC6C407E4<03>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page99 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 91 Load Initial Key Response Format:   <STX>91[Status]<ETX>[LRC] Message length: Variable (max 7 bytes.) Usage: Confirmation of the initial key loading. PP190 will also show a message “IPEK n loaded” (n = 1 or 2) to confirm the success loading of initial key of set 1 and set 2 visually. Message element:   Field  Length  Value and description <STX>  1  <02> 91  2  Message ID [Status]  1..2  ‘0’ if successful ‘1’ + [Error Code] if process failed. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please reference message90.  Error codes: Code Meaning '1' Processing message 90 without authentication, process authentication at first '2' IPEK and KSN format error: not hexadecimal character. '3' Data length error. '4' Internal memory allocation error. '5'  Cannot read internal flash memory. ‘7’  Cannot write new IPEK into flash memory. ‘F’  DUKPT 1 million limit reached or flash memory write cycle has been exhausted.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page100 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 94 Load Second Initial Key Request Format:   <STX>94[IPEK][KSN][Key MAC]<ETX>[LRC] Message length: Fixed 41 bytes (57 bytes for TDES initial key). Usage: Load second set of DUKPT initial key and serial number key to PP190. Consequent keys will be generated using provided data.   If 32-characters (double length) initial key being loaded, PP190 will do key generation, PIN entry, and other DUKPT operations in TDES manner. PP190 will reject message 94 if it has not yet get the authentication. See Symmetric Keys Loading Authentication section for detail. Note: VISA required key serial number format are as follows: 4’F’ characters, a 6-digit keyset identifier, 5-digit device ID, followed by a ‘0’,   i.e. “FF FF kk kk kk dd dd d0”  Message element:   Field  Length  Value and description <STX>  1  <02> 94  2  Message ID [IPEK]  16 or 32 Initial PIN encryption key. 32-characters Initial key will make PP190 act in TDES DUKPT mode. Format: hexadecimal string. [KSN]  20 Key serial number used in generating consequent keys. Format: hexadecimal string. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 94      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message 91 <ACK>/<NAK>/<EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page101 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message 96 Select Active Key Set Format:   <STX>96[keyset]<ETX>[LRC] Message length: Fixed 6 bytes. Usage: Select active key set for following transactions. This parameter is kept in flash memory and lasts until next 96 message or DUKPT life cycle ends.  Message element:   Request frame (HOST to PIN Pad) Field  Length  Value and description <STX>  1  <02> 96  2  Message ID [keyset]  1  ASCII character ‘0’ = First key set ‘1’ = Second key set <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message 96 request frame     <ACK>/<NAK>/<EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page102 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Section 8    Remote key injection method
PIN Pad 190 Programmer’s Manual   2014-02-06  Page103 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message R00 Load Vender Public Key Format:   <STX>R00[Last pkt][Pkt no.]<FS>[Exp len][Exp data]<FS>[Mod data]<ETX>[LRC] Message length: Variable Usage: This message is used to load vender public key to PP190. If vender public key is already exists in PP190, PP190 will return error, in this circumstance, user should use R01 command to update vender public key. Message element: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R00  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last. [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ <FS>  1  (optional, only first packet need) <1C>, Field separator [Exp len]  1  (optional, only first packet need) Exponent length, value from ‘1’ to ‘8’. [Exp data] 1~8 (optional, only first packet need) Exponent data, hexadecimal string for exponent data. <FS>  1  (optional, only first packet need) <1C>, Field separator [Mod data] Var. (Max. 256-byte per transmit) (optional) Hexadecimal string for  Modulus data to be loaded, and the modulus total length must be 512 bytes. <ETX>  1  <03> [LRC]  1  Checksum  Note: Modulus data must be  256 bytes  (2048 bits), and it should convert to hexadecimal string for transmission, so modulus data is 512 bytes hexadecimal string in transmission. Because hardware restriction, host could send R00 command with several packet: 1.  First packet contain: [Last pkt][Pkt no.]<FS>[Exp len][Exp data]<FS>a part of [Mod data]. 2. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Mod data]. 3. PP190 will send R00 response (R00F if success) after host send all command   packet ([Last pkt] = ‘1’).
PIN Pad 190 Programmer’s Manual   2014-02-06  Page104 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Note: If the received packet’s time interval is over 1 minute, PP190 will return timeout error. Reply fame (PP190 to HOST) Field  Length  Value and description <STX>  1  <02> R00  3  Message ID [Status]  1  Status byte: ‘0’: Packet received success, and wait for next packet. ‘1’: Error occurred, abort transmission. ‘F’: Load vendor public key successfully. [ErrCode]  1  (optional, if [Status] = 1) ‘1’ = Command format error. ‘2’ = Memory allocate fail. ‘3’ = Vendor public key has loaded. ‘4’  =  received modulus length is not equal to user assigned length. ‘5’ = Flash write fail. '6' = Timeout. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad Message R00     <ACK> <EOT>   Message R00 ([Status] = '0') <ACK> <EOT>   Message R00 (while modulus data not end)     <ACK>   <EOT>     Message R00 ([Status] = '0') ………………  ……..  ………………… Message  R00(with [Last pkt] = ‘1’)      <ACK>   <EOT>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page105 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Send message R00 (reply frame). <ACK>   <EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page106 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message R01 Update RSA Key Format:<STX>R01[Last pkt][Pkt no.][Key type][Data type]<FS>[Sig data]<ETX>[LRC] (1st message) <STX>R01[Last pkt][Pkt no.][Key type][Data type]<FS>[Exp data]<ETX>[LRC] (2ndmessage) <STX>R01[Last pkt][Pkt no.][Key type][Data type]<FS>[Mod data]<ETX>[LRC] (3rd message)  Message length: Variable. Usage: This message is used to update PP190 Remote Key Injection RSA key (include Vender Public Key、Server Public Key、PP190 Private Key and PP190 Public Key). Description: Steps for update RSA key. 1. Calculate SHA256 hash value of new RSA key(32-byte), and following RSA Cryptography Standard to generate signature packet, reference to PKCS#1 v2.2: a.  Generate an hexadecimal string PS with value 0xff, PS length equals to Sig msg Len - T Len - 3. b. Since PP190 only use SHA256 to generate hash value, the DigestInfo value of T (D)should be:  (0x) 30 31 30 0d 06 09 60 86 48 01 65 03 04 02 01 05 00 04 20  and T should be:     D || Hash value of new RSA key(32-byte). c. Sig msg = 0x00 || 0x01 || PS || 0x00 || T. 2. Generate RSA digital signature by Vender private key. 3. Issue 1st message R01 to PIN pad. 4. PIN pad will use Vender public key to authenticate the message format (the length of digital signature should equal to RSA modulus stored in PIN pad) and issues 1st message R01 with the authenticate result. 5. Issue 2nd and 3rd message R01 to PIN pad. 6. PIN pad will calculate the hash value of the [Exponent] and [Modulus] data from 2nd and 3rd message R01 and compare the hash value that decrypt from 1st message R01.   Message element: 1st: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R01  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page107 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ [Key type]  1  (optional, only first packet need) ‘1’: Vender public key ‘2’: Server public key ‘3’: PP190 public key ‘4’: PP190 private key [Data type]  1  (optional, only first packet need) Value: ‘1’ (Signature data). <FS>  1  (optional, only first packet need) <1C>, Field separator [Sig data]  Var. (Max. 256-byte per transmit) (optional) Hexadecimal string for Signature data of RSA key, and the total signature length must be 512 bytes. <ETX>  1  <03> [LRC]  1  Checksum  2nd: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R01  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last. [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ [Key type]  1  (optional, only first packet need) ‘1’: Vender public key ‘2’: Server public key ‘3’: PP190 public key ‘4’: PP190 private key [Data type]  1  (optional, only first packet need) Value: ‘2’ (Exponent data). <FS>  1  (optional, only first packet need) <1C>, Field separator [Exp data]  Var. (Max. 256-byte per transmit) (optional) Hexadecimal string for exponent data. (1~8 bytes for public key and
PIN Pad 190 Programmer’s Manual   2014-02-06  Page108 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  for private key must be 512 bytes.) <ETX>  1  <03> [LRC]  1  Checksum  3rd: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R01  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last. [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ [Key type]  1  (optional, only first packet need) ‘1’: Vender public key ‘2’: Server public key ‘3’: PP190 public key ‘4’: PP190 private key [Data type]  1  (optional, only first packet need) Value: ‘3’ (Modulus data). <FS>  1  (optional, only first packet need) <1C>, Field separator Modulus data Var. (Max. 256-byte per transmit) (optional) Hexadecimal string for Modulus data to be loaded, and the total signature length must be 512 bytes.. <ETX>  1  <03> [LRC]  1  Checksum  Note:   1st message: Signature data must be 256 bytes, and it should convert to hexadecimal string for transmission, so signature data is 512 bytes hexadecimal string in transmission. Because hardware restriction, host could send R01 command with several packets: 1. First packet contain: [Last pkt][Pkt no.][Key type][Data type]<FS>a part of [Sig data]. 2. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Sig data]. 3. PP190 will send load success response (R010 if success) after host send all signature data packet ([Last pkt] = ‘1’).
PIN Pad 190 Programmer’s Manual   2014-02-06  Page109 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   2nd message: Exponent data could be 1~8 bytes (public key) or 512 bytes (PP190 private key) hexadecimal string, host could send R01 command as following: 1. First packet contain: If [Key type] = 4 (PP190 private key): [Last pkt][Pkt no.][Key type][Data type]<FS>a part of [Exp data]. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Exp data]. Else [Last pkt][Pkt no.][Key type][Data type]<FS>[Exp data] 2. PP190 will send load success response (R010) after host send all exponent data packet ([Last pkt] = ‘1’).    3rd message: Modulus data must be 512 bytes hexadecimal string, host could send R01 command with several packet: 1. First packet contain: [Last pkt][Pkt no.][Key type][Data type]<FS>a part of [Mod data]. 2. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Mod data]. 3. PP190 will send load success response (R01F if success) after host send all modulus data packet ([Last pkt] = ‘1’).   Reply fame (PP190 to HOST) Field  Length  Value and description <STX>  1  <02> R01  3  Message ID [Status]  1  Status byte: ‘0’: Packet received success, and wait for next packet. ‘1’: Error occurred, abort transmission. ‘F’: Load vendor public key successfully. [ErrCode]  1  (optional, if [Status] = ‘1’) ASCII character. ‘1’ = SHA engine is busy ‘2’ = Vendor public key not loaded ‘3’ = Memory allocate fail ‘4’ = Command format error ‘5’ = Last state error
PIN Pad 190 Programmer’s Manual   2014-02-06  Page110 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages ‘6’ = Packet number error ‘7’ = Key type error   ‘8’ = Data type error   ‘9’ = Range of key length error ‘A’ = Received modulus length is not equal to user assigned length. ‘B’ = Signature original data format error ‘C’ = Hash compare error ‘D’ = Flash write error ‘E’ = Flash erase error 'H' = AES engneer error 'I' = Timeout <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad 1st Message R01     <ACK> <EOT>   Message R01 ([Status] = '0') <ACK> <EOT>   1st Message R01 (while data not end)     <ACK> <EOT>   Message R01 ([Status] = '0') ………………  ……..  …………………   Message R01 ([Status] = '0') 1st Message R01 (with [Last pkt] = ‘1’)      <ACK> <EOT>   Message R01 ([Status] = '0') 2nd Message R01     <ACK> <EOT>   Message R01 ([Status] = '0')
PIN Pad 190 Programmer’s Manual   2014-02-06  Page111 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages <ACK> <EOT>   2nd Message R01 (while data not end)     <ACK> <EOT>   Message R01 ([Status] = '0') ………………  ……..  …………………   Message R01 ([Status] = '0') 2nd Message R01 (with [Last pkt] = ‘1’)      <ACK> <EOT>   Message R01 ([Status] = '0') 3rd Message R01     <ACK> <EOT>   Message R01 ([Status] = '0') <ACK> <EOT>   3rd Message R01 (while data not end)     <ACK> <EOT>   Message R01 ([Status] = '0') ………………  ……..  …………………   Message R01 ([Status] = '0') 3rd Message R01 (with [Last pkt] = ‘1’)      <ACK> <EOT>   Send message R01 (reply frame). <ACK> <EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page112 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message R02 Remote Key Injection Format:   <STX>R02[Last pkt][Pkt no.][Data type]<FS>[Sig data]<ETX>[LRC] (1st message) <STX>R02[Last pkt][Pkt no.][Data type]<FS>[Enc data]<ETX>[LRC] (2nd message) Message length: Variable Usage: This message is used to load Terminal Master Key(TMK) to PP190. (Terminal Master Key length should be 16-byte or 24-byte) Description: Steps for Remote Key Injection: 1. Send R02 packet, and PP190 will reply R02 with Sig[PPpub]Vendorpriv to host, authenticate the Signature of PP190 Public Key, then use this public key to encrypt the Key Encryption Key (MK or DUKPT) and use server’s private key to sign the hash value of Key Encryption Key (MK or DUKPT). 2. Calculate SHA256 hash value of Terminal Master Key (32-byte), and following RSA Cryptography Standard to generate signature packet, reference to PKCS#1 v2.2: a.  Generate an hexadecimal string PS with value 0xff, PS length equals to Sig msg Len - T Len - 3. b. Since PP190 only use SHA256 to generate hash value, the DigestInfo value of T (D)should be:     (0x) 30 31 30 0d 06 09 60 86 48 01 65 03 04 02 01 05 00 04 20     and T should be:       D || Hash value of new KEK key(32-byte). c. Sig msg = 0x00 || 0x01 || PS || 0x00 || T. 3. Generate RSA digital signature by Server private key: Sig data = RSA(Sig msg) 4. Issue 1st message R02 to PIN pad. 5. PIN pad will use Server public key to authenticate the message format (the length of digital signature should equal to RSA modulus stored in PIN pad) and issues 1st message R02 with the authenticate result. 6. Use Terminal Master Key to generate a PKCS#1 encryption format, reference to PKCS#1 v2.2: a.  Generate an hexadecimal string PS with random generated hex characters (PS could not have any 0x00), PS length equals to Enc data Len - KEK Len - 3. b. Enc msg = 0x00 || 0x02 || PS || 0x00 || KEK. 7. Generate Enc data by PP190 public key, which should be pre-load to host before R02 command: Enc data = RSA(Enc msg) 8. Issue 2nd message R02 to PIN pad. 9. PIN pad will use PP190 private key to decrypt data from 2nd message R02, and calculate the hash value of the TMK, then compare the hash value that decrypt from 1st message R02.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page113 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Message element: 1st: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R02  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last. [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ [Data type]  1  (optional, only first packet need) Value: ‘1’(Signature data). <FS>  1  (optional, only first packet need) <1C>, Field separator [Sig data]  Var. (Max. 256-byte per transmit) (optional) Hexadecimal string for Signature data. [Signature data]: Hash value of TMK with PKCS#1 format signed by Server private key. The signature total length must be 512 bytes. <ETX>  1  <03> [LRC]  1  Checksum  2nd: Request fame (HOST to PP190) Field  Length  Value and description <STX>  1  <02> R02  3  Message ID [Last pkt]  1  ‘0’: packet is not last. ‘1’: packet is last. [Pkt no.]  1  Packet sequence number. Range:’1’~’9’ [Data type]  1  (optional, only first packet need) Value: ‘2’ (Encrypted KEK data). <FS>  1  (optional, only first packet need) <1C>, Field separator [Enc data]  Var. (Max. 256-byte (optional) Hexadecimal string for encrypted data.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page114 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages per transmit) [Encrypt data]: Encryption value of TMK (by PP190 public key). The encrypted total length must be 512 bytes. <ETX>  1  <03> [LRC]  1  Checksum  Note:   1st message: Signature data must be 256 bytes, and it should convert to hexadecimal string for transmission, so signature data is 512 bytes Hex string in transmission. Because hardware restriction, host could send R02 command with several packet: 1. First packet contain: [Last pkt][Pkt no.][Data type]<FS>a part of [Sig data]. 2. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Sig data]. 3. PP190 will send load success response (R020 if success) after host send all signature data packet ([Last pkt] = ‘1’).   2nd message: Encrypted data must be  512 bytes hexadecimal string, host could send  R02  command with several packet: 1. First packet contain: [Last pkt][Pkt no.][Data type]<FS>a part of [Enc data]. 2. The rest of packets contains: [Last pkt][Pkt no.] and the rest of [Enc data]. 3. PP190 will send load success response (R02F if success) after host send all encrypted data packet ([last pkt] = ‘1’). Reply fame (PP190 to HOST) Field  Length  Value and description <STX>  1  <02> R02  3  Message ID [Sig data] 512 bytes  (Only first R02 packet gets response with [Sig data].) Hexadecimal string for Sig[PPpub]Vendorpriv. Signature of PP190 public key. [Status]  1  Status byte: ‘0’: Packet received success, and wait for next packet. ‘1’: Error occurred, abort transmission. ‘F’: Load vendor public key successfully. [ErrCode]  1  (optional, if [Status] = 1)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page115 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages ‘1’ = SHA engine is busy ‘2’ = KEK length error ‘3’ = Memory allocate fail ‘4’ = Command format error ‘5’ = Last state error ‘6’ = Packet number error ‘7’ = Verify encrypted format error ‘8’ = Data type error   ‘9’ = Range of key length error ‘A’ = Received modulus length is not equal to user assigned length. ‘B’ = Signature original data format error ‘C’ = PP190 public key is not loaded ‘D’ = Server public key is not loaded ‘E’ = PP190 private key is not loaded ‘H’ = KEK load fail. ‘I’ = AES engineer fail. ‘J’ = Hash compare error ‘K’ = Time out. ‘L’ = PP190 private key verify fail. ‘M’ = PP190 vendor public key is not loaded. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction PIN Pad Send R02 packet     <ACK> <EOT>   Message R02 with [Sig data] <ACK> <EOT>   1st Message R02     <ACK> <EOT>   Message R02 ([Status] = '0') <ACK> <EOT>   1st Message R02 (while data not end) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page116 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   <ACK> <EOT>   Message R02 ([Status] = '0') ………………  ……..  …………………   Message R02 ([Status] = '0') 1st Message R02 (with [Last pkt] = ’1’)      <ACK> <EOT>   Message R02 ([Status] = '0') 2nd Message R02     <ACK> <EOT>   Message R02 ([Status] = '0') <ACK> <EOT>   2nd Message R02 (while data not end)     <ACK> <EOT>   Message R02 ([Status] = '0') ………………  ……..  …………………   Message R02 ([Status] = '0') 2nd Message R02 (with [Last pkt]=’1’)      Send message R02 (reply frame). <ACK> <EOT> 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page117 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Section 9  EMV Level 2 transaction messages EMV Level2 transaction messages are divided into 2 groups. One is EMV-configuration data operation messages (T01, T03, T05, T07, T09 and T0B) and the other one is EMV-transaction messages (T11, T13, T15, T17, T19, T1C, T21, T25, T27 and T29).    The EMV transaction messages issuing sequence is control by PIN pad, an invalid sequence will terminate EMV transaction. At the beginning of EMV transaction, user has to issue messages T11 to make PIN pad negotiate with card and generate a candidate list of EMV-application that supported by PIN pad and card both, and then select a highest priority one automatically or selected by user (according to the terminal configuration data installed in PIN pad), finally return the EMV-application name. Message T15 is used for terminal-side to transmit transaction information such as amount and then PIN pad do a complete transaction with card if the transaction needs not to be authorized online. Terminal can issue message T1D to transmit additional transaction data into PIN pad for EMV transaction, such as online response data, magnetic stripe card track data. Message T17 is applied if the transaction needs to be authorized online, terminal-side will transmit necessary information via this message to PIN pad to continue the rest steps of transaction. If the response from host contains issuer script (see EMV Book), terminal-side applies message T19 to input these scripts into PIN pad and PIN pad will issue these scripts at appropriate time to card. Message T1C is used to terminate an EMV transaction. Finally, message T21 is used for terminal-side to get the transaction information through EMV transaction.  Terminal can apply Txx messages to handle a complete EMV transaction except that the transaction must be changed to magnetic stripe card processing. According to EMV rule, if terminal fails to read IC card, the transaction could be change to magnetic stripe card transaction. Because of different types of magnetic stripe card, the magnetic stripe card processing should be taken by terminal. Terminal could issue message Q1 provided by PIN pad to make user swipe his card and then issue message 70 to complete a magnetic stripe card transaction. In this situation, terminal will get response of T11 message that indicates an failed IC card read, terminal should then issue message T1D, T15 and T17 to PIN pad for batch data capture. The flow chart for changing to magnetic stripe card processing could be referred in “Overall EMV level 2 transaction flow reference” section.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page118 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T51 Terminal Configuration Setup Format:   <STX>T51[Pkt No.][Total Pkts]<SUB>[DO]<ETX>[LRC]  Message length: Variable.   Usage: Host can use this command to send terminal configuration data to  PIN  pad, this command can be sent many times. PIN pad will save those data inside and apply those data when do the transaction. PIN pad will send the message T52 (Terminal Configuration Setup Response) to host. Message element: Field Length Value and description    <STX>  1  <02> T51  3  Message ID Pkt No.  1  Decimal. Packet sequence number (1 ~ 9)(ex. 2) Total Pkts  1  Decimal. Total packets (1~9)(ex. 8). <SUB>  1  <1A, Optional, only if [DO] is existed DO Var. Data Object, format as below <ETX>  1  <03> [LRC]  1  Checksum  Data Object:   Each <DO> shall include three data field: [Tag#] || [Format] || [Value], and each field shall delimit with a <FS>. Each data object is delimited by a <SUB> to construct multiple <DO>. The [tag#] defined in EMV 4.1 Book3 Annex A and specific [tag#] defined at Appendix D of this manual have the pre-defined data format and length range, those [tag#] must follow up the rule, otherwise the PIN Pad will reject this data setup.   Data Format: (Please also refer to EMV 4.1 BOOK3, section 4.3) Format Description 1  a - Alphabetic data (a ~z, A~Z) 2  b - unsigned binary numbers or bit combinations 3  an - Alphanumeric data (a ~z, A~Z, 0~9) 4  ans - Alphanumeric Special data (Characters defined in ISO8859) 5  cn - Compressed numeric data (0~9, left justify, pad hexadecimal ‘F’s. Ex. 12 34 56 12 3F FF) 6  n - Numeric data (0~9, right justify, pad leading hexadecimal zeroes. Ex. 00 00 00 01 23 45) 7  var - Variable data (Any bit combination)  Note: Please be careful that only when all data objects send to PIN Pad correctly with sequence packet number within total packets number, these data will be saved to PIN Pad. Any update shall include whole items of <DO>, because previous setup <DO> will be lost when update!
PIN Pad 190 Programmer’s Manual   2014-02-06  Page119 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Note.   If the data format is ‘2’ (binary), ‘5’(compressed numeric), ‘6’(numeric) or ‘7’(variable data), the [value] correspond to these format can not be sent with these format directly in message T51. It shall be converted to hexadecimal string and with pad char ‘F’ in the last one for format ‘cn’ if this tag# has odd chars or with pad char ‘0’ in the first one for format ‘b’ or ‘n’ if this tag# has odd chars.    Example: (Clear the terminal configuration data and then setup new data.) Merchant Category Code: 0000 (Numerical) Terminal ID:      SmartPOS (Ascii) UI Capability:      0x01 (binary)  <STX>T5111<SUB>9f15<FS>6<FS>0000<SUB>9f1c<FS>3<FS>SmartPOS<SUB> 50000002<FS>2<FS>01<ETX>[LRC]  PIN pad will check if terminal downloads minimum set of terminal-related information into PIN pad. The download process will be failed if there is not enough data in this message. Please refer to appendix E for minimum set of terminal-related data  Message flow: HOST Direction   PIN Pad 1st Message T51     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   1st Message T52 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   2nd Message T51     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   2nd Message T52 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   …  …  … Last one Message T51 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page120 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Last one Message T52 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page121 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T52 Terminal Configuration Setup Response Format:   <STX>T52[Res][Reason][Err Msg]<ETX>[LRC] Message length: Variable. Usage: The response message of command T51.    Message element:   Field  Length  Value and description <STX>  1  <02> T52  3  Message ID [Res]  1  ‘0’: Ok, ‘1’: Fail [Reason]  1  <Optional, if Res = ‘1’> ‘1’: Fatal Error ‘2’: Format Error ‘3’: Invalid Data Object format. ‘4’: Invalid Tag value [Err Message]  8  Optional, if Reason = ‘1’, Hex decimal string [Err Tag Number]  Var. Optional, if Reason = ‘3’ or ‘4’, Hex decimal string <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T51.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page122 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T53 Certificate Authority Public Key Setup Format:   <STX>T53[Pkt No.][Total Pkts][RID][PKI][Key Size][Hash Alg][PK Alg][Exponent Len][Exponent][Hash]<ETX>[LRC] <STX> T53[Pkt No.][Total Pkts][Modulus Len][Modulus]<ETX>[LRC] Message length: Variable.   Usage: Host can use this command to send the Certificate Authority Public key data to PIN pad, each command can only setup one key but this command can be sent many times. PIN pad will save those key data inside and use those data when do the transaction. PIN pad will send the message T54 (Certificate Authority Public Key Setup Response) to host. The data installed into PIN pad via this message, PIN pad will save it in internal storage structure with a name same as concatenation of value in [RID] and [PKI] fields. Ex. value in [RID] field is “A000000003”, value in [PKI] filed is “90”, PIN pad will save these data and give an ID as “A00000000390”.  Message element:   1st Packet (Load RSA public key): Field  Length  Value and description <STX>  1  <02> T53  3  Message ID Pkt No.  1  Decimal. Packet sequence number (1 ~ 9) Total Pkts  1  Decimal. Total packets (1~9)(ex. 8). RID 10 Hexadecimal string, the left 5 bytes of EMV Application ID. PKI  2  Public Key Index, hexadecimal string. (Refer to EMV 4.1, tag ‘9f22’) Key Size  4 Public Key size, hexadecimal string. Key: [Hash Alg] || [PK Alg] || [Exponent Len] || [Exponent] || [Hash] || [Modulus Len] || [Modulus] The value is displayed as big endian and is half of the key hex string. For example: ‘00A9’=169 bytes. And key string will be 338 bytes. Hash Algorithm 2  Hash Algorithm Index, hexadecimal string ‘01’: SHA-1. Now, PIN pad accepts only ‘01’. PK Algorithm 2  Public Key Algorithm, hexadecimal string ‘01’: RSA digital signature. Now, PIN pad accepts only ‘01’. Exponent Len 2  Public Key Exponent size, hexadecimal string. For example:
PIN Pad 190 Programmer’s Manual   2014-02-06  Page123 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages ‘03’ = 3 bytes Exponent Var. Public Key Exponent, hexadecimal ‘03’: 3 ‘010001’: 216+1 Hash 40 Hash checksum, hexadecimal <ETX>  1  <03> [LRC]  1  Checksum  2nd Packet (Load RSA public key): Field  Length  Value and description <STX>  1  <02> T53  3  Message ID Pkt No.  1  Decimal. Packet sequence number (1 ~ 9) Total Pkts  1  Decimal. Total packets (1~9)(ex. 8). Modulus Len  2 Public Key Exponent size, hexadecimal string. For example: ‘80’ = 128 bytes = 1024 bits Modulus Var. (Max. 256-byte per transmit) Public Key Modulus, presented in hexadecimal, data length = 2*[ Modulus Len] <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad 1st Message T53     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   1st CA Public Key Setup Response Message T54 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   2nd Message T53     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page124 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   2nd CA Public Key Setup Response Message T54 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)    Command Example: 1. Visa CA 51, RID: A000000003 <02>T5313A0000000035100A901010103B9D248075A3F23B522FE45573E04374DC4995D71<03><LRC> <02>T532390DB5FA29D1FDA8C1634B04DCCFF148ABEE63C772035C79851D3512107586E02A917F7C7E885E7C4A7D529710A145334CE67DC412CB1597B77AA2543B98D19CF2CB80C522BDBEA0F1B113FA2C86216C8C610A2D58F29CF3355CEB1BD3EF410D1EDD1F7AE0F16897979DE28C6EF293E0A19282BD1D793F1331523FC71A228800468<03><LRC> <02>T5333C01A3653D14C6B4851A5C029478E757F<03><LRC> 2. Paypass CA EF, RID: A000000004 <02>T5313A000000004EF01110101010321766EBB0EE122AFB65D7845B73DB46BAB65427A<03><LRC> <02>T5323F8A191CB87473F29349B5D60A88B3EAEE0973AA6F1A082F358D849FDDFF9C091F899EDA9792CAF09EF28F5D22404B88A2293EEBBC1949C43BEA4D60CFD879A1539544E09E0F09F60F065B2BF2A13ECC705F3D468B9D33AE77AD9D3F19CA40F23DCF5EB7C04DC8F69EBA565B1EBCB4686CD274785530FF6F6E9EE43AA43FDB02CE0<03><LRC> <02>T53330DAEC15C7B8FD6A9B394BABA419D3F6DC85E16569BE8E76989688EFEA2DF22FF7D35C043338DEAA982A02B866DE5328519EBBCD6F03CDD686673847F84DB651AB86C28CF1462562C577B853564A290C8556D818531268D25CC98A4CC6A0BDFFFDA2DCCA3A94C998559E307FDDF915006D9A987B07DDAEB3B<03><LRC>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page125 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T54 Certificate Authority Public Key Setup Response Format:   <STX>T54[Resp][Reason][Err Msg]<ETX>[LRC] Message length: Variable. Usage: The response message of command T53.    Message element:   1st, 2nd Packet: Field  Length  Value and description <STX>  1  <02> T54  3  Message ID Sequence  1  1 / 2 (first/second part of RSA public key) [Resp]  1  ‘0’: Ok, ‘1’: Fail [Reason]  1  Option if [Resp] is ‘1’, ‘1’: Fatal Error ‘2’: Format Error ‘3’: Authentication Fail [Err Message]  8  Optional, if Reason = ‘1’, Hex String <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T53.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page126 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T55 EMV Application Configuration Setup Format:   <STX>T55[PktNo.][Total Pkts]<SUB>[TranType]<SUB>[KID]<SUB> [AID]<SUB>[DO]<ETX>[LRC]  <STX>T55[Pkt No.][Total Pkts]<SUB>[DO]<ETX>[LRC] Message length: Variable.   Usage: Host can use this command to send the EMV application configuration data to PIN pad, this command can be sent many times but each command is only for one application. PIN pad will save those data inside and use those data when do the transaction. PIN pad will response the message T56 (EMV Application Configuration Setup Response) to host. The data installed into PIN pad via this message, PIN pad will save it in internal storage structure with a name same as in [AID] field.  Message element: 1st Message: Field Length Value and description    <STX>  1  <02> T55  3  Message ID Pkt No.  1  Decimal. Packet sequence number (1 ~ 9) Total Pkts  1  Decimal. Total packets (1~9)(ex. 8). <SUB>  1  Optional, if Pkt No is 1 <1A> [TranType]  2  Optional, if Pkt No is 1. Hexadecimal, Transaction Type. <SUB>  1  Optional, if Pkt No is 1 <1A> [KID]  2  Optional, if Pkt No is 1. Hexadecimal, kernel ID. <SUB>  1  Optional, if Pkt No is 1 <1A> AID 10~32 Optional, if Pkt No is 1. EMV Application ID, refer to EMV 4.1 <SUB>  1  Optional, only if [DO] is existed DO Var. (Max. 220-byte per transmit) Data Object, format as below <ETX>  1  <03> [LRC]  1  Checksum Rest of Message (If there are 2 more messages): Field Length Value and description    <STX>  1  <02> T55  3  Message ID
PIN Pad 190 Programmer’s Manual   2014-02-06  Page127 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages <SUB>  1  Optional, only if [DO] is existed DO Var. (Max. 256-byte per transmit) Data Object, format as below <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page128 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Data Format: (Please also refer to EMV 4.1 BOOK3, section 4.3) Format Description 1  a - Alphabetic data (a ~z, A~Z) 2  b - unsigned binary numbers or bit combinations 3  an - Alphanumeric data (a ~z, A~Z, 0~9) 4  ans - Alphanumeric Special data (Characters defined in ISO8859) 5  cn - Compressed numeric data (0~9, left justify, pad hexadecimal ‘F’s. Ex. 12 34 56 12 3F FF) 6  n - Numeric data (0~9, right justify, pad leading hexadecimal zeroes. Ex. 00 00 00 01 23 45) 7  var - Variable data (Any bit combination)  Data Object:   Each <DO> shall include three data field: [Tag#] || [Format] || [Value], and each field shall delimit with a <FS>. Each data object is delimited by a <SUB> to construct multiple <DO>. The [tag#] defined in EMV 4.1 Book3 Annex A and specific [tag#] defined at Appendix D of this manual have the pre-defined data format and length range, those [tag#] must follow up the rule, otherwise the PIN Pad will reject this data setup.  Note. If the data format is ‘2’ (binary), ‘5’(compressed numeric), ‘6’(numeric) or ‘7’(variable data), the [value] correspond to these format can not be sent with these format directly in message T55. It shall be converted to hexadecimal string and with pad char ‘F’ in the last one for format ‘cn’ if this tag# has odd chars or with pad char ‘0’ in the first one for format ‘b’ or ‘n’ if this tag# has odd chars.  Example: Default TDOL: 97 07 9f 02 06 95 05 9b 02 (binary) Threshold Value for Biased Random Selection: 00 00 00 00 40 00(numerical) Max. Target percentage to be used for Biased Random selection: 100 (decimal) / 0x46 (binary)  <STX>T5511<SUB>00<SUB>03<SUB>A00000031010<SUB>97<FS>2<FS>97079f020695059b02<SUB>40000004<FS>6<FS>000000004000<SUB>40000006<FS>2<FS>46<ETX>[LRC] PIN pad saves these data and give an ID as “A00000031010” to this group of data.    Special Tag# defined by PIN pad: (Not EMV defined) Name Description Format Tag Length Application Selection Indicator See below  n  40000001  1 Threshold Value for Biased Random Selection See below  n  40000004  6 Target Percentage to be used  See below  b  40000005  1
PIN Pad 190 Programmer’s Manual   2014-02-06  Page129 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages for Biased Random Selection Maximum Target Percentage to be used for Biased Random Selection See below  b  40000006  1 Terminal Action Code - Default See below  b  40000007  5 Terminal Action Code - Denial See below  b  40000008  5 Terminal Action Code - Online See below  b  40000009  5 Data Tags required in Online message (ARQC) See below  b  4000000A var. Data tags required in reversal message See below  b  4000000D var. Data tags for batch data capture See below  b  40000010 var. ARC Approve See below  b  4000001A var. ARC Decline See below  b  4000001B var. ARC Referral See below  b  4000001C var.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page130 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Message flow: HOST Direction   PIN Pad 1st Message T55      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   1st Message T56 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   2nd Message T55     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Application Select Response. 2nd Message T56 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   …  …  … Last one Message T55     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Application Select Response. Last one Message T56 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)    PIN pad will check if terminal downloads minimum set of EMV Application-related information into PIN pad. The download process will be failed if there is not enough data in this message. Please refer to appendix E for minimum set of EMV Application -related data
PIN Pad 190 Programmer’s Manual   2014-02-06  Page131 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T56 EMV Application Configuration Setup Response Format:   <STX>T56[Resp][Reason][Err Msg]<ETX>[LRC] Message length: Variable. Usage: The response message of command T55.    Message element:   Field  Length  Value and description <STX>  1  <02> T56  3  Message ID [Resp]  1  ‘0’: Ok, ‘1’: Fail [Reason]  1  Option if [Resp] is ‘1’,   ‘1’: Fatal Error ‘2’: Format Error ‘3’: Invalid Data Object format. ‘4’: Invalid Tag value [Err Message]  8  Optional, if Reason = ‘1’Hex String <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T55.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page132 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T61 Start Transaction Format:   <STX>T61<SUB>[AmtAuth]<SUB>[AmtOther]<SUB> [CurExponent][CurCode]<SUB>[TranType]<SUB>[TranInfo]<SUB> [Account Type]<SUB>[Force Online]<SUB> [Encrypted Session key]  <ETX>[LRC] Message length: Variable.   Usage: After receive this message command T61, PIN Pad will perform an completed EMV transaction flow (the flow will cover ‘Initiate Application’ through ‘Completion’, see EMV 4.1, book 3, chap 8.2, figure 6 - transaction flow example) based on the selected EMV application that has corrected application name on the T12 (Application Select response), PIN pad will also prompt user to do the appropriated entry when presented, like confirm or enter PIN code. PIN pad will send the message T62 (Start Transaction Response) to host.    If the IC card can’t be read (which has known from T12 response code with “T1214” when in message T11 processing and terminal changed to do magnetic stripe card processing; please refer the Notes in message T12), then after receive this message T61, PIN pad will not process the EMV transaction flow but in place of just storing the information provided from this message and return the message T62 with result code “A1” to ask terminal to go line to get the authorization then send back a message T71 to finish this transaction. Terminal could have extra operation on magnetic stripe card transaction (like issue message Q1 to read track data and issue message 70 for PIN entry, and so on.) before issue this message T61. Message element:   Field  Length  Value and description <STX>  1  <02> T61  3  Message ID <SUB>  1  <1A> [AmtAuth] 12 Hexadecimal, Amount Authrozied, will be stored at tag ‘0x9f02’ <SUB>  1  <1A> [AmtOther] 12 Hexadecimal, Amount Other, will be stored at tag ‘0x9f03’ <SUB>  1  <1A> [CurExponent]  1  Hexadecimal, stored at tag ‘0x5f36’ [CurCode] 3  Hexadecimal, stored at tag ‘0x5f2a’.   For example, USD$ = 0x840 <SUB>  1  <1A>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page133 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages [TranType] 2 Hexadecimal, Transaction Type, will be stored at tag ‘0x9c’ <SUB>  1  <1A> [TranInfo] 2  Transaction Info, will be stored at tag ‘0x60000001’ <SUB>  1  <1A> [Account Type] 2  Account Type, stored at tag ‘0x5f57’ <SUB>  1  <1A> [Force Online] 1 1: Force Online, only valid if this terminal has the capability of support online authorization. <SUB>  1  <1A>, optional [Encrypted Session key] 16 or 32 Optional, DES or TDES session key  that used to encrypt PIN entry when CVM ask online PIN verify. If the CVM ask online PIN verify but this session key does not input, PIN pad will ignore the PIN entry request and indicate that no PIN is entered in the TVR register.   <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message T61      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Start Transaction Response. Message T62 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)    Note: If [Encrypted Session key] is input, the tag# (for example, 0xDF02) to store this encrypted session key shall be defined at tag#50000005, please refer T01 command’s notes how to setup this tag#DF02.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page134 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T62 Start Transaction Response Format:   <STX>T62[Status][Reason][Err Message][Result]<SUB> <Advice Need> <Reversal Need> <Financial Need><ETX>[LRC] Message length: Variable. Usage: The message contains the transaction result on the smart card to be sent to terminal. Message element:   Field  Length  Value and description <STX>  1  <02> T62  3  Message ID Status  1  0:OK; 1:Fail Reason  1  Optional. (If Status = 1) 1:Fatal Error 2:Command Format Error [Err Message]  8  Optional, if Reason = ‘1’Hex String [Result]  2  Optional. (If Status = 0) ‘Y1’: Offline Approved, ‘Z1’: Offline Declined ‘Y3’: Unable to go online,      Offline Approved ‘Z3’: Unable to go online, Offline Decline. ‘Y4’: Online Approved ‘Z4’: Online Decline ‘A1’: Online Authorize Request,   ‘A4’: Application reselection. <Advice Need>  1  Optional, only valid if [Result] is “A1”. RFU. <Reversal Need> 1  0: Terminal does not need to send a reversal to   host for this transaction 1: Terminal should send a reversal to host for this  transaction. <Financial Need> 1  Optional, only valid if [Result] is “A1”. RFU <ETX>  1  <03> [LRC]  1  Checksum  Note: If the [Result] is ‘A1’, then terminal should send online authorization request to issuer host; and after done, terminal shall send message T71 to PIN pad to continue transaction. (See EMV 4.1, book 3, chap 9, figure 7, 8)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page135 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Note: If the transaction is switched to MSR processing, T62 will always return “A1” in [Result] field.  Note: if the previous selected application on IC card can’t do the transaction (for example, this application has blocked) but has another application ID within this IC card, PIN pad will response ‘A4’ to let terminal know and terminal can issue message T13 to select another application ID and issue message T61 to re-start the transaction. Please refer the paragraph of “Ref. 5 Packet command flow for first EMV application is blocked”  in the section of “Overall EMV Level 2 transaction flow reference”.  Message flow: Please refer to message T61.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page136 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T63 Get Transaction Result’s Data Format:   <STX>T63[DOL]<ETX>[LRC] Message length: Var.   Usage: PIN Pad will retrieve the data that list on the DOL after EMV transaction done. PIN Pad will send the message T64 (Get Transaction Result’s Data Response) to host. Message element:    Field  Length  Value and description <STX>  1  <02> T63  3  Message ID DOL Var Data Object List, each object is expressed by tag number, and <SUB> is used to delimit each object. For example, 9F12<SUB>9A<SUB>9F02<SUB>…. <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message T63     <ACK> (Good LRC) <NAK> (Bad LRC) <EOT> after 3 NAKs   Get Transaction Result’s Data Response. Message T64 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page137 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T64 Get Transaction Result’s Data Response Format: <STX>T64[DO]<ETX>[LRC] Message length: Var. Usage: The message contains the transaction result’s data to be sent to host. Message element:   Field  Length  Value and description <STX>  1  <02> T64  3  Message ID [DO]  Var. Data Object, each data object is expressed by TLV format with an <FS> delimit in each field, and <SUB> is used to delimit each object. For example: 9F12<FS>0F<FS>CREDITO DE VISA<SUB>9A<FS>06<FS>050806<SUB>……. <ETX>  1  <03> [LRC]  1  Checksum  Data Object: PIN pad will return series of data object that list on the [DOL] field in the message T64 with TLV (tag || length|| value) format as below:  [EMV Tag Number (2 ~ 8 byte)] <FS> [Length (2byte)] <FS> [Value] <SUB> [EMV Tag Number (2 ~ 8 byte)] <FS> [Length (2byte)] <FS> [Value] <SUB> . . . . . . . .   [EMV Tag Number (2 ~ 8 byte)] <FS> [Length (2byte)] <FS> [Value].    Note: When PIN Pad response these data object, it will convert these value from binary value to hex decimal string if the data object format is “b” or “cn” or “n”.  Message flow: Please refer to message T63.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page138 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T65 Get Online authorization Data Format: <STX>T65<ETX>[LRC] Message length: 6. Usage: Issue this message to get data (EMV) for online authorization. Message element:   Field  Length  Value and description <STX>  1  <02> T65  3  Message ID <ETX>  1  <03> [LRC]  1  Checksum   While the EMV transaction must be authorized online, terminal shall issue message T65 to get the necessary data for online authorization from PIN pad. And PIN pad will wait terminal to send one message T71 to tell the PIN Pad the go online authorization result  User shall load a data object’s tag list in tag# 4000000A for online authorization data into PIN Pad when do the application configuration setup (message T55), PIN pad will search the corresponding values according to this tag list and return it at message T66 after receive message T65 from terminal. Please refer to Appendix D for more details.  Message flow: HOST Direction   PIN Pad Message T65     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message T66 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page139 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T66 Response of Get Online authorization Data message Format: <STX>T66 [online authorization data]<ETX>[LRC] Message length: var. Usage: Return online authorization data to terminal. Message element:   Field  Length  Value and description <STX>  1  <02> T28  3  Message ID [Online authorization data] Var. Hex string. Optional, if this transaction needs to be authorized online. <ETX>  1  <03> [LRC]  1  Checksum  Online authorization data: According to the tag list of online authorization data (refer to appendix D) which defined at tag# 4000000A, PIN pad will search the corresponding values according to this tag list and return series of data object with TLV (tag || length|| value) format as below:  [EMV Tag Number (2 ~ 8 byte)] || [Length (2byte)] || [Value] <SUB> [EMV Tag Number (2 ~ 8 byte)] || [Length (2byte)] || [Value] <SUB> . . . . . . . .   [EMV Tag Number (2 ~ 8 byte)] || [Length (2byte)] || [Value].    PIN pad can return at maximum 256 bytes of data as one record, the right part of data will be ignored if the length record is greater than 256 byte.  When PIN Pad response these data object, it will convert these value from binary value to hex decimal string if the data object format is “b” or “cn” or “n”. For example, the data of one record is 0x9F02 || 06 || 000000001100 || 5A || 10 || 11223344556677889900AABBCCDDEEFF, terminal will see “9F0206000000001100<SUB>5A1011223344556677889900AABBCCDDEEFF”.  Message flow: Please refer to message T65
PIN Pad 190 Programmer’s Manual   2014-02-06  Page140 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T71 Send Online Authorized Code Format:   <STX>T71[Online Res]<SUB>[ARC][IAD]<ETX>[LRC] Message length: Fixed 7 or 16 bytes.   Usage: After receive this message T71, PIN Pad will continue to perform the EMV transaction flow if the previous T62 response result is ‘A1’ (online authorized request, see EMV 4.1, book 3, chap 8.2, figure 6 –  transaction flow example).  PIN  pad  will  response the message T62 (Start Transaction Response) to this T71 to host.  Message element:    Field  Length  Value and description <STX>  1  <02> T71  3  Message ID Online Res  1  ‘0’: Unable to go online <ETX>  1  <03> [LRC]  1  Checksum  OR Field  Length  Value and description <STX>  1  <02> T71  3  Message ID Online Res  1  ‘1’: Get Online Authorize Response, <SUB>  1  <1A> ARC  2 Authorisation Response code, ASCII (0~9, A~Z). Please see Note 1. <SUB>  1  <1A> [IAD] 16~32 Optional,  Issuer Authentication Data, Hex string. if there is IAD response from remote host , terminal shall send this to PIN pad. <ETX>  1  <03> [LRC]  1  Checksum  Note 1: These acceptable ARC code shall be matched with the pre-defined code at tag# 4000001A (ARC approval) and tag#4000001B (ARC decline) and tag# 4000001C (ARC referral) (please refer Appendix D) where these tag value can be setup by message T05. Please note the data format in tag# 4000001A to tag# 4000001C are binary but here [ARC] format is ASCII. So there
PIN Pad 190 Programmer’s Manual   2014-02-06  Page141 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages shall have a convert. For example, if the ARC approval code “Y0”, then the binary value in tag# 4000001A shall be 0x5930.  OR (If the transaction is changed to Magnetic stripe card processing) Field  Length  Value and description <STX>  1  <02> T71  3  Message ID Online Res  1  ‘3’: MSR Online Approve ‘4’: MSR Online Decline, <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message T71      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Start Transaction Response. Message T62 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page142 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T73 Send Issuer Script Command Format:   <STX>T73[IS]<ETX>[LRC] Message length: Var. Usage: PIN Pad performs the Issuer script processing as in EMV transaction flow after received this command from the host those are the response message when doing online authorization. This command can be send many times if too many script commands need to be processed, but the last one should be send before T71 command.   Message element:       Issuer Script Format: (see EMV 4.1, book 3, chap 10.10, Figure 10)    T  L  T  L  Script ID Commands ‘71’ or ‘72’ Including Script ID, tags, lengths ‘9F18’  ‘04’  Identifier (4 bytes) Issuer Script Command Format (see below)   Issuer Script Command Format: (see EMV 4.1, book 3, chap 10.10, Figure 11)    T1 L1 V1 T2 L2 V2 T3 L3 V3 Tx Lx Vx ‘86’  L(V1) Cmd  ‘86’  L(V2) Cmd  ‘86’  L(V3) Cmd  ‘86’  L(Vx) cmd  Field  Length  Value and description <STX>  1  <02> T73  3  Message ID IS Var. Issuer Script, format as follow. Hex string. <ETX>  1  <03> [LRC]  1  Checksum
PIN Pad 190 Programmer’s Manual   2014-02-06  Page143 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T74 Send Issuer Script Command Response Format:   <STX>T74[Status][Reason][Err Message]<ETX>[LRC] Message length: Variable. Usage: The message response the command T73.    Message element:   Field  Length  Value and description <STX>  1  <02> T74  3  Message ID Status  1  0:OK ; 1:Fail Reason  1  Optional. (if Status = 1) 1:Fatal Error 2:Command Format Error [Err Message]  8  Optional, if Reason = ‘1’, Hex String <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T73.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page144 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Message T75 Revocation List Setup Format:   <STX>T75<SUB>[RID][SN][PKI]<ETX>[LRC]  Message length: Fixed 25 bytes Usage: Host can use this command to send revocation key information to  PIN  pad, this command can be sent many times. PIN pad will save those information inside and check those information when do the transaction. PIN pad will send the message T76 (Revocation List Setup Response) to host. Message element: Field Length Value and description    <STX>  1  <02> T75  3  Message ID <SUB>  1  Separator RID 10 The RID for revocated public key. Present in hexstring. SN  6 The serial number of the revocated public key. Present in hexstring. PKI  2 The public key index of the revocated key. Present in hexstring. <ETX>  1  <03> [LRC]  1  Checksum  Example: Revocation list information RID: A0 00 00 00 03 SN: 00 00 01 PKI: 51  <STX>T75<SUB> A00000000300000151<ETX>[LRC]  Message flow: HOST Direction   PIN Pad Message T75      <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Message T76 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs) 
PIN Pad 190 Programmer’s Manual   2014-02-06  Page145 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T76 Revocation List Setup Response Format:   <STX>T76[Res][Reason][Err Msg]<ETX>[LRC] Message length: Variable. Usage: The response message of command T75.    Message element: Field  Length  Value and description <STX>  1  <02> T76  3  Message ID [Res]  1  ‘0’: Ok, ‘1’: Fail [Reason]  1  <Optional, if Res = ‘1’> ‘1’: Fatal error   ‘2’: Invalid Data format ‘3’: Revocation list is full ‘4’: The added info exists [Err Message]  8  Optional, if Reason = ‘1’, Hex decimal string <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T75.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page146 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T77 Exception List Setup Format:   <STX>T77<SUB>[PAN Len][PAN]<ETX>[LRC] Message length: Variable. Usage: Host can use this command to send the exception pan to PIN pad. PIN pad will save the information inside and check them when do the transaction. Once the transaction pan is on the exception list, the transaction will be terminated. PIN pad will send the message T78 (Exception List Setup Response) to host.  Message element: Field  Length  Value and description <STX>  1  <02> T77  3  Message ID <SUB>  1  Separator PAN Len  2  The length of PAN digits. Present in hexstring. PAN var Numeric string <ETX>  1  <03> [LRC]  1  Checksum  Message flow: HOST Direction   PIN Pad Message T77     <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)   Exception List Setup Response Message T78 <ACK> (Good LRC) <NAK> (Bad LRC) (<EOT> after 3 NAKs)    Command Example: PAN: 47 61 73 90 01 01 00 10 <STX>T77<SUB>104761739001010010<ETX><LRC>
PIN Pad 190 Programmer’s Manual   2014-02-06  Page147 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages   Message T78 Exception List Setup Response Format:   <STX>T78[Resp][Reason][Err Msg]<ETX>[LRC] Message length: Variable. Usage: The response message of command T77.    Message element:   Field  Length  Value and description <STX>  1  <02> T78  3  Message ID [Resp]  1  ‘0’: Ok, ‘1’: Fail [Reason]  1  Option if [Resp] is ‘1’, ‘1’: Fatal Error ‘2’: Format Error ‘3’: Exception List is full ‘4’: PAN exists [Err Message]  8  Optional, if Reason = ‘1’, Hex String <ETX>  1  <03> [LRC]  1  Checksum  Message flow: Please refer to message T77.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page148 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  Appendix A  Key management This PIN pad is designed to encrypt Personal Identification Numbers (PIN) as they are entered from the keypad, store the encrypted data in its memory and then transmit it to the HOST as requested.   Because the data-encryption standard (DES) and RSA algorithm are in the public domain, the security of the functions of the PP190 depend on the security of the key that is used in processing the algorithm. Therefore, after you load cryptographic keys into the PP190, the keys cannot be read. They are placed AES encrypted by a randomly generated AES key, resident in a battery-powered register. Once security is breached, the AES key will be erased, and all encrypted DES master keys become unusable. You can design a secure method for handling your keys when you are isolated from the PIN keypad, using the provisions for loading the keys. Randomly generate your keys, and store and distribute your keys in a secure, controlled manner that you can audit.   An independent Tamper Resistant Security Module (TRSM) is required for secure key injection process. UIC provides a software key injection utility (UICKIT for Windows) as demo for safely and manageable key injection procedure. Please refer to UICKIT programming manual for detail.  PP190 supports following management schemes:  1. Master/session key (MK/SK):   PP190 can store 16 master keys, key ID 0 to 9 are for MK/SK PIN entry (They can be PIN master key or PIN key), key ID B to  E is for generate or verify MAC, depend on its usage and mode settings. (They can be MAC master key or MAC key), F for master key transportation (It can be only key loading key). These master keys cannot be used in other ways (e.g. designer cannot use PIN entry keys for MAC generation.) Session keys (working keys) are transmitted from the HOST, encrypted by the master key for every transaction. Customer’s PIN is encrypted using the decrypted working key or by selected master key (If the selected one is with key usage “P0”). Thus the master keys must exist before any transaction can take place. PP190 can use 8 bytes DES key format or 16 / 24 bytes Triple DES key format, the working key can also be 16 bytes TDES key. When doing transactions using MK/SK scheme, firmware of PP190 applies a DES calculation count limiter (only 10 transactions are allowed in 5 minutes period.) to comply with PCI PED security requirement (average one transaction per 30 seconds.) This constraint is set to deter attacker using huge saturation DES transaction to detect master key in PP190. 2. ANSI TR31 Specified Key Bundle Key Attribute: When loading master keys into PP190 in encrypted format, the key data is wrapped by a key bundle specified in ANSI TR-31 2010 specification. 1. Key usage: indicate what usage of a key. “K0”, indicates that this key is used for key transportation; “P0”, indicates that this key is used for PIN entry directly;
PIN Pad 190 Programmer’s Manual   2014-02-06  Page149 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages “D0”, indicates that this key is used for data transportation; “M1” indicates that this key is used for MAC calculation directly by ISO 9797-1 method 1. “M3” indicates that this key is used for MAC calculation directly by ISO 9797-1 method 3. “B1”, indicates that this key is used for DUKPT initial key (ANSI TR-31 2010). 2. Algorithm: indicate what algorithm will be used with the key. “D” : DES algorithm “T”: TDES algorithm (double or triple length key) “A”: AES algorithm (RFU) 3. Mode: indicate what cryptograph operation will be applied with the key “D”: Decryption “E”: Encryption “G”: MAC generation “V”: MAC verification “X”: Key derivation (DUKPT) 4. Version (RFU): It should be 00. 5. Export (RFU): It should be “N”.      If the key usage is “K0”, the length of key must be 16 bytes or 24 bytes (algorithm must be “T”).            Key Architecture and limitation Group Key ID Length Usage Algorithm Mode Encrypt under PIN 0~9 8~24 P0 D or T  E  KLK     16~24 K0  T  D  KLK Data  A  RFU RFU RFU RFU RFU MAC B~E  8  M1  D  G  KLK     16 M3  T  G / V KLK     16~24 K0  T  D  KLK KLK  F  16~24 K0  T  D  KLK  Key attribute and limitation for IPEK IPEK Length Usage Algorithm Mode Encrypt under IPEK0 or IPEK1 8 or 16 B1 D or T  X  KLK 1. All the keys injected in cipher-text must be encrypted by key derived from KLK and calculate a MAC value by key derived from KLK 2. For key with usage “K0”, the length must be 16 bytes or 24 bytes. 3. For MAC key with usage “M1”, the length of key must be 8 bytes (DES-MAC). 4. For MAC key with usage “M3”, the length of key must be 16 bytes (TDES-MAC).
PIN Pad 190 Programmer’s Manual   2014-02-06  Page150 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages 5. Duplicate key injection is not allowed. (except IPEK0 and IPEK1) 6. The length of injected key in cipher-text should be equal to or less then the length of KLK.      Key Injection     To inject clear-text key (Key ID: 0~9, A~F) into PP190, the default attributes will be as following, Key usage = “K0”, Algorithm = “T”, Mode = “D”, Version = “00” and export = “N”     To inject cipher-text key into PP190, user has to assign these attributes.       For Key 0 ~ 9,   Key usage should be “K0” or “P0”, algorithm should be “T” or “D”, mode should be “D” (If for “K0” usage) or “E” (If for “D0” usage).   For Key B ~ E,   Key usage should be “K0”, “M1” or “M3”, algorithm should be “T” (If for “K0” or “M3” usage) or “D” (If for “M1” usage), mode should be “D” (If for “K0” usage) or “G” (If for “M1” or “M3” usage). For Key F,     Key usage should be “K0”, algorithm should be “T”.     For IPEK 0~1     Key usage could be any 2 bytes data, algorithm should be “D” or “T”, mode should be “E”.  Inject key in cipher-text (TR31 format) For Key 0~9, A~F <SI>02[Key ID][KBH][Encrypted KEY][MAC]<SO>, where [KBH] + [Encrypted KEY] + [MAC] is   TR31 block.  For IPEK0 <STX>90[KBH][Optional KBH][DUKPT0][MAC]<ETX>, where [KBH and Optional KBH] +   [IPEK0] + [MAC] is TR31 block. For IPEK1 <STX>94[KBH][Optional KBH][DUKPT1][MAC]<ETX>, where [KBH and Optional KBH] +   [IPEK1] + [MAC] is TR31 block.  KBH (Key Block Header – ASCII format): A[4byte  –  length of TR31 block][2byte -  Usage][1byte  -  Algorithm] [1byte -  Mode][2byte  - Version][1byte - Export][2byte - option][2byte - rfu]  Optional KBH (For DUKPT use only): [2byte: Optional Block ID, fixed as “KS”][2byte: Optional Block Length, fixed as “18”][20byte: Optional Block Data, put key serial number (refer to ANSI X9.24 SMID) in this field]  Encrypted KEY Block: 1. Derive Key1 by XOR KLK with 0x45
PIN Pad 190 Programmer’s Manual   2014-02-06  Page151 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages 2. Generate new key block, [2byte number indicate the key in bits][key][random padding] 3. Encrypt the new key block by Key1 with first 8byte of KBH as IV in CBC mode and get encrypted key block.  MAC: 1. Derive Key2 by XOR KLK with 0x4D 2.  Concatenate KBH with Optional KBH (if any) and encrypted key block and get new key block 2. 3. Encrypt the new key block 2 by Key2 without IV in CBC mode and get the last 8 bytes. 4. Get the first 4 bytes of result as MAC value  Example 1: KLK: 0123456789ABCDEFFEDCBA9876543210 New MK (Key ID = 1, key usage = “K0”): 89E88CF7931444F334BD7547FC3F380C Generate KBH: KBH = A | 0072 | K0 | T | D | 00 | N | 0000     Generate Encrypted KEY Block: 1. Derive K1 for encryption: 44660022CCEE88AABB99FFDD33117755 K2 for MAC value: 4C6E082AC4E680A2B391F7D53B197F5D 2. Key length = 16 bytes (128 bits = 0x80), 6 byte random padding = 720DF563BB07, New key block = 008089E88CF7931444F334BD7547FC3F380C720DF563BB07. 3. IV = first 8 byte of KBH (“A0072K0T”) = 41303037324B3054, apply TDES-CBC on new key block by K1 with IV and get encrypted key block = D078A2657E5B57972CD3 D308E05E1FE519B316309AA6354A MAC: 1. Concatenate KBH and encrypted key block = 41303037324B30544430304E303 03030D078A2657E5B57972CD3 D308E05E1FE519B316309AA6354A 2. Apply TDES-CBC  on new key block 2 by K2 without IV and get last 8 byte result  = 668071B5B73CC024 3. MAC value = 668071B5 4. The final TR31 block = A0072K0TD00N0000 -  D078A2657E5B57972CD3D308E05E 1FE519B316309AA6354A - 668071B5  Send message 02 to load this new key in cipher-text: <SI>021A0072K0TD00N0000D078A2657E5B57972CD3D308E05E1FE519B316309AA6354A66 8071B5<SO>[LRC]   3. Derived Unique Key Per Transaction (DUKPT): PP190 Implements ANSI X9.24-2002 and ANSI TR31 key management scheme for DUKPT.
PIN Pad 190 Programmer’s Manual   2014-02-06  Page152 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Authorized personnel can load 8bytes/16bytes Initial keys (also known as IPEK) and Key serial number (also known as ‘Security Management Information Data-SMID’ in ANSI X9.24). Every time when  PP190 finished a PIN entry transaction, a new key will be calculated. Every single transaction will use different key in order to prevent attacker to detect specific keys in any transactions.    The symmetric keys (MKSK/DUKPT) structure is shown as following: Master Key 0 (PIN entry master keys / PIN keys) Master Key 1 (PIN entry master keys / PIN keys) …  Master Key 9 (PIN entry master keys / PIN keys) ... Master Key B~E (MAC master keys) (MAC master keys / MAC keys) Master Key F (Key Loading Key) Master Key G (MSR master key / MSR data key)  4. RSA public key:   PP190 supports RSA encryption when processing EMV level 2 offline transactions with smart cards.    5. Second DUKPT Key Set of PP190:   PP190 provides 2nd key set of DUKPT operation for customer’s scalability. Message 90 is used to initialize first key set, with message 94 to initialize second key set. User must issue message 96 to select preferred key set before doing DUKPT transactions. These two key set are independent with each other, and both accepts double length key for TDES capability. Ether key set reaches 1million transaction limit will lock down PP190. In real operation, authorized user can load a 8byte DES initial key to key set 1 and a 16byte TDES initial key to key set 2 before PIN pad is deployed. At first use can transact with key set 1. When backbone system ready, user can use message 96 to select key set 2 to switch to TDES transaction immediately.  6. Triple DES (TDES) capability: DUKPT Set 0 DUKPT Set 1
PIN Pad 190 Programmer’s Manual   2014-02-06  Page153 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages TDES means that DES algorithm is applied three times on the data to be encrypted before it is sent over the line.  PP190 can detect key length when loading keys (message 02 for Master/Session key and message 90/94 for DUKPT) and doing transactions (Master/Session key message 70, Z60, Z62). If a 32 or 48 characters (16 or 24 byte) key is used, PP190 will treat all transactions using this key as TDES enabled, else PP190 use DES operation.   TDES algorithm needs a 16-byte key, which separated as L-key (leftmost 8 bytes) and R-key (rightmost 8 bytes). PP190 defaults EDE order for TDES encrypting operation as follows:  Clear Text  DES encryption via L-key  DES decryption via R-key  DES encryption via L-key  Ciphered Text EDE order of TDES operation – 16 byte key. (Data decrypting process is the reverse of encrypting process.)  Clear Text  DES encryption via L-key  DES decryption via Middle-key  DES encryption via R-key  Ciphered Text EDE order of TDES operation – 24 byte key. (Data decrypting process is the reverse of encrypting process.)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page154 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  7. TDES – ECB Encryption:          8. TDES – CBC Encryption:           9. DES-MAC (ISO 9797-1 method 1)          D1 D2 TDES-E  TDES-E  K K … DN TDES-E  K C1 C2 CN D1 D2 TDES-E  TDES-E  K K … DN TDES-E  K C1 C2 CN IV … CN-1 D1 D2 DES-E  DES-E  K K … DN DES-E  K C1 C2 CN IV … CN-1 MAC
PIN Pad 190 Programmer’s Manual   2014-02-06  Page155 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages  10. TDES – MAC (ISO 9797-1 method 3)                     D1 D2 DES-E  DES-E  KL KL … DN DES-E  KL C1 C2 CN IV … CN-1 DES-D  KR DES-E  KL MAC
PIN Pad 190 Programmer’s Manual   2014-02-06  Page156 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Appendix B  PIN Block Format   ANSI x9.8 format (MK/SK, DUKPT, and Offline clear text PIN entry) PP190 outputs ANSI X9.8 PIN blocks. Its format as follows:  PIN Block Format Bit  0-3  4-7  8-11 12-15 16-19 20-23 24-27 28-31 32-35 36-39 40-43 44-47 48-51 52-55 56-59 60-63 Value C  N  P  P  P  P  P/F P/F P/F P/F P/F P/F P/F P/F  F  F Bit field explanation: C - Control field (Format number). Value = 0000 (Does not support Format 1 or Format 3)   N - PIN length entered field. Value = 0100 to 1100 (4-12) (0x4 – 0xC) P - PIN digit. Value = 0000 to 1001 (0-9) F - Fill digit. Value = 1111 (F)   P/F - Pin digit or fill digit, as determined by PIN Length N. PIN Length is 4 to 12  Primary Account Number Block (PANB) Format Bit  0-3  4-7  8-11 12-15 16-19 20-23 24-27 28-31 32-35 36-39 40-43 44-47 48-51 52-55 56-59 60-63 Value 0  0  0  0  A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 Bit field explanation: A - The twelve rightmost digits of the primary account number (PAN), excluding the check digit. A1 is the most significant digit and A12 is the digit immediately preceding the PAN’s check digit. If the primary account number excluding the check digit is less than twelve digits, the digits are right justified and padded on the left with zeroes. Permissible values are 0000 to 1001.   0 - Pad digit = 0000. The first four digits of the account number block are always padded with this value.  Formatted Clear-Text PIN Block The PIN and account number blocks are Exclusive ORed before being assembled in the DES (Data Encryption Standard) input register. When the account number is not available, only the PIN block is assembled in the DES input register. PP190 will output DES/TDES encrypted PIN block with message 71 and delete clear-text PIN block immediately after transaction completed. Example:   Account Number: 1234567890-6 (6 is check number and will be ignored) PIN: 8780 The PIN block =   04 87 80 FF FF FF FF FF The PANB =     00 00 12 34 56 78 90 00 Formatted PIN block = 04 87 92 CB A9 87 6F FF (Data to be encrypted)
PIN Pad 190 Programmer’s Manual   2014-02-06  Page157 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Appendix C    Fixed Prompts for Z2/Z3 authenticated mode  Prompt ID Display 001 ACCOUNT NUMBER 002 AIRCRAFT TAIL NO 003 BADGE NUMBER 004 CARD NUMBER 005 CARD SEC CODE 006 CASH BACK AMOUNT 007 CID CODE 008 CVC CODE 009 CVN CODE 010 CVV CODE 011 CUSTOMER CODE 012 CUSTOMER DATA 013 CUSTOMER ID 014  CUSTOMER NUMBER 015 CUSTOMER REF 016 CUSTOMER REF NO. 017 DATE OF BIRTH 018 DEPARTMENT NO. 019 DRIVER ID 020 DRIVER LICENSE 021 DRIVER NUMBER 022 EMPLOYEE ID 023 EMPLOYEE NUMBER 024 ENTER 025 ENTER ACCOUNT # 026 ENTER AIR TAIL # 027 ENTER BADGE # 028 ENTER BIRTH DATE 029 ENTER CARD # 030 ENTER CASH BACK 031 ENTER CUST # 032 ENTER CUST CODE 033 ENTER CUST DATA 034 ENTER CUST ID Prompt ID Display 035 ENTER CUST REF 036 ENTER CUST REF # 037 ENTER CID CODE 038 ENTER CVC CODE 039 ENTER CVN CODE 040 ENTER CVV CODE 041 ENTER DEPT # 042 ENTER DOB 043 ENTER DRIVER # 044 ENTER DRIVER ID 045 ENTER DRIVER LIC 046 ENTER EMP ID 047 ENTER EMPLOYEE # 048 ENTER EXP DATE 049 ENTER FLEET # 050 ENTER FLEET DATA 051 ENTER HOME PHONE 052 ENTER ID # 053 ENTER JOB # 054 ENTER ODOMETER 055 ENTER PHONE # 056 ENTER PO # 057 ENTER REF # 058 ENTER ROUTE # 059 ENTER SEC CODE 060 ENTER SERIAL # 061 ENTER SOC SEC # 062 ENTER SSN 063 ENTER STREET # 064 ENTER TRAILER # 065 ENTER USER ID 066 ENTER V-CODE 067  ENTER VEH CARD # 068 ENTER VEHICLE #
PIN Pad 190 Programmer’s Manual   2014-02-06  Page158 Uniform Industrial Corp. Proprietary and Confidential  Total 160 pages Prompt ID Display 069 ENTER VEHICLE ID 070 ENTER WORK PHONE 071 ENTER ZIP CODE 072 EXPIRATION DATE 073 FLEET DATA 074 FLEET NUMBER 075 HOME PHONE NO. 076 ID NUMBER 077 JOB NUMBER 078 MMDDYY 079 MMDDYYYY 080 MMYY 081 ODOMETER READING 082 OR PHONE # 083 OR PHONE NUMBER 084 PHONE NUMBER 085 PLEASE 086 PLEASE ENTER 087 PLEASE RE-ENTER 088 PO NUMBER 089 RE-ENTER 090 REFERENCE NUMBER 091 RESTRICTION CODE 092 ROUTE NUMBER 093 SECURITY CODE 094 SERIAL NUMBER 095 SOCIAL SEC NO. 096 STREET NUMBER 097 SWIPE CARD 098 SWIPE CARD OR 099 TRAILER NUMBER 100 USER ID 101  V-CODE 102 VEHICLE CARD NO. 103 VEHICLE ID 104 VEHICLE NUMBER 105 WORK PHONE NO. Prompt ID Display 106 ZIP CODE 107 ENTER CARD 108 ENTER ST ADDRESS 109 STREET ADDRESS 110 SWIPE/TAP CARD 111 SWIPE/INSERT CRD 112 TAP/INSERT CARD 113 OR ENTER ACCT # 114 OR ENTER 115 TAP CARD 116 TAP CARD OR 117 INSERT CARD 118 INSERT CARD OR 119 SELECT CARD TYPE 120 CREDIT 121 DEBIT 122 EBT 123 GIFT 124 LOYALTY 125 GIFT/LOYALTY 126 HGM 127 STORED VALUE 128 GSB 129 ONECARD 130 GSB/ONECARD