45DEPARTMENT OPTIONS Edit Name Set Location Information Delete DepartmentSet Department Quick Key Set Avoid New DepartmentEdit ChannelEdit Name See Data Naming.Set Department Quick KeyThis assigns a quick key to the Department and the scanner will scan the Department when the key is enabled. The default setting is . (no quick key). If you don’t assign a Quick Key to a departmtnt, it will always be scanned unless you Avoid it.0-99 or . (for no quick key)Note: Pressing the rst number of a 2-digit quick key will get you closer. For example, press 1 for 10, 2 for 20, etc., then scroll to the second digit.Edit Channel See Channel Options.Set Location Information – This allows you program a location for the Department to use with Location Control enabled or with a GPS. You can program a circle with a radial range or multiple rectangles as a location. See Set Up GPS rst.CircleSet LatitudeEnter the latitude. Press ./no to toggle N or S, and press E/yes.Set LongitudeEnter the longitude. Press ./no to toggle E or W, and press E/yes.Set Range See also Understanding Range.0-6000Rectangles New RectangleLatitude - Top LeftEnter the latitude. Press ./no to toggle N or S, and press E/yes.Longitude - Top LeftEnter the longitude. Press ./no to toggle E or W, and press E/yes.Latitude - Bottom RightEnter the latitude. Press ./no to toggle N or S, and press E/yes.Longitude - Bottom RightEnter the longitude. Press ./no to toggle E or W, and press E/yes.Stored RectangleEdit Rectangle See Rectangles above.Delete RectangleAt Confirm Delete? press E/yes or ./no.Set Avoid – This determines whether a Department will be scanned or not. Temporary Avoids cancel when you cycle power.
46The default setting is Stop Avoiding. Stop Avoiding, Temporary Avoid, or Permanent AvoidSee also Scan Avoids.Delete Department – Deletes the Department.At Confirm Delete? press E/yes or ./no.New Department – See New Department.PROGRAMMING FREQUENCIES/TGIDSQUICKLY STORING A FREQUENCY/TGIDIn scan mode press Channel to hold on any channel.Enter the Frequency or TGID and press E/yes. See also Edit Frequency/TGID.Note: You have to enter a TGID/frequency in the proper format for the system you are holding on. Example: You can’t enter a Motorola Type II TGID when holding on an LTR system.Store a Frequency/TGID into a “Quick Save” Favorites ListAt Quick Freq/TGID Save?, press E/yes.The scanner will save the Frequency/ TGID in a Favorites List called Quick Save Favorites List, in a System called Quick Save System, (with no quick keys assigned), in a Department called Quick Save Department.Store a Frequency/TGID into a Current Favorites List At Quick Freq/TGID Save?, press ./no.At inquiry Press E/yes.At Select Favorites List, scroll to the Favorites List where you want to store the Frequecy/TGID and press E/yes.At Select System, scroll to the System where you want to store the Frequency/TGID and press E/yes.At Select Department, scroll to the Department where you want to store the Frequency/TGID and press E/yes.After storing the Frequency/TGID, you will be at the Channel Options menu to complete the settings for the new channel. If you don’t want to edit the channel settings press Avoid to return.NEW CHANNEL/CHANNEL OPTIONSPress Menu then scroll to Manage Favorites and press E/yes.Scroll to the Favorites List and press E/yes. Scroll to Review/Edit System and press E/yes. Scroll to the System and press E/yes.Scroll to Edit Department and press E/yes.Scroll to the Department and press E/yes.Scroll to Edit Channel and press E/yes.To Create a New Channel, scroll to New Channel and press E/yes.
47At Input Frequency/TGID, enter the frequency or TGID and press E/yes.To Edit an Existing Channel, scroll to the Channel and press E/yes.CHANNEL OPTIONSNote: Not all options will appear for all channels. Edit Name Set Attenuator Set AlertEdit Frequency or TGID Set Service Type Set AvoidSet Audio Type Set Delay Time Volume OffsetSet Number Tag Set Priority Delete ChannelSet Modulation New ChannelEdit Name See Data Naming.Edit Frequency or TGIDEnter the frequency or TGID and press E/yes to save. See also Entering IDs for Partial IDs.To enter a Conventional Frequency, enter the Frequency and press E/yes.To enter a Motorola Type II TGID, enter the TGID and press E/yes.To enter a Motorola Type I TGID, enter the Block Number and Fleet Number, press ./no twice for a hyphen, then enter the Subfleet and press E/yes.To enter an EDACS ID in AFS format, enter the Agency Number, press ./no twice for a hyphen, then the Fleet and Subfleet and press E/yes. To enter an EDACS TGID in Decimal format, enter the TGID and press E/yes.To enter a LTR TGID, enter the Area Code (0 or 1) and press ./no twice for a hyphen, then enter the Home Repeater Number (01-20) and press ./no once, then the User ID (1-254) and press E/yes.To enter an I-Call ID, press ./no once then enter the ID and press E/yes.To enter a Wildcard I-Call ID, press ./no once then enter 0 and press E/yes.To enter Hexadecimal IDs, see Data Naming.Note: If the channel is already stored in the group TGID or Frequency Exists Accept? (Y/N) appears. Press ./no to return. You can also Avoid wildcard IDs.Set Audio Type (Conventional/Motorola Only) – Select All if this channel might contain both digital and analog signals. If you are sure the channel is analog set the channel to Analog Only. This will prevent the P25 Waiting Time for the conventional system from losing the rst part of the transmission up to the wait time you set there.All. The scanner determines whether the audio is analog or digital.Digital Only. The scanner will receive the channel only if it is carrying APCO 25 digital audio.P25 NAC Option (Conventional Only)Search - the scanner searches and displays any NAC tone received.Set P25 NAC - allows you to program a NAC code. See Data Naming.Note: You can also store a (blinking) NAC code when receiving the frequency in scan mode by pressing E/yes.Analog Only. The scanner will only receive analog audio. Set CTCSS/DCS
48Search. The scanner searches and displays any CTCSS or DCS tone.Note: You can also store a (blinking) CTCSS/DCS tone when receiving a frequency in scan mode by pressing E/yes.CTCSS. Scroll to the desired CTCSS tone. Press E/yes to save.DCS. Scroll to the desired DCS tone. Press E/yes to save. Set Lockout. Scroll to CTCSS or DCS and press E/yes. Scroll to the desired tone you want avoided and press E/yes to save.Set Number Tag – This allows you to number a Channel so you can access it quickly from scan hold mode. The default setting is no number tag. See also Using Number Tags.0-999, Blank (No number tag)Set Modulation (Conventional Only) – This setting selects the modulation used for the channel. The default setting is Auto.Auto, AM, FM, NFM, WFM, or FMB (FM Broadcast)See also Scan Modulation.Set Attenuator (Conventional Only) – This setting controls whether the scanner attenuates signals on the Channel by about 20 dB. The default setting is Off.On or OffSee also Scan Attenuation.Set Service Type – This sets the Service Type for The Channel. The Appendix has a list of Service Types and their general descriptions. Default is Custom 1.Scroll to the Service Type and press E/yes.Set Delay Time – This sets (in seconds) the amount of time the scanner stays on a channel after the transmission has ended before moving to the next channel. A negative delay will force a resume after that number of seconds. The default setting is 2 seconds.-10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 sec.Set Priority – This sets the channel as a priority channel while scanning. The default setting is Off.Note: To use Priority ID Scan you must also enable Priority ID Scan for each System. See also Priority Scanning.On or OffSet Alert – This setting controls when and how the scanner alerts you if the channel becomes active. The default setting is Off.Set Alert ToneAlert 1-9 or Off.Set LevelLevel 1-15 or Auto (the master volume level). Set Alert LightSet Color Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White.
49Set PatternOn, Slow Blink, or Fast Blink.Set Avoid – This determines whether a channel will be scanned or not. Temporary Avoids cancel you cycle power. The default setting is Stop Avoiding.Stop Avoiding, Temporary Avoid, or Permanent AvoidSee also Scan Avoids.Volume Offset – This sets the Volume Offset for the Channel.-3, -2, -1, 0, 1, 2, or 3Note: You can also toggle volume offset for a channel in scan hold mode by pressing Func then 0(LVL).Delete Channel – Deletes the Channel.At Confirm Delete? press E/yes or ./no.New Channel – See New Channel.SET SCAN SELECTIONManage Quick Key Status – This is one way to enable or disable your System quick keys and Favorites Lists quick keys. The other way is using the number keys on the keypad. See Selecting Quick Keys.Favorites Quick KeyScroll to each Favorites List quick key and press E/yes to enable or disable.System Quick KeyScroll to each Favorites List and press E/yes.Favorites ListScroll to each System quick key and press E/yes to enable or disable.Set Nationwide Systems (Database Only) – This setting enables or disables Nationwide systems in the Database, only when the Database is being scanned.Scroll to each Nationwide System and press E/yes to enable or disable.Select Lists to Monitor – This setting enables or disables your Favorites Lists and the database for scanning. You must rst enable each list here, before you can enable the quick key for the list or you will see Nothing to Scan.Note: You will need to set a location to enable the database.Scroll to the Full Database, Search with Scan, or each Favorites List, then press E/yes to enable or disable. For Search with Scan, see also Search with Scan and Edit Custom Search.Set All Lists Off/On – These settings turn all Favorites Lists on or off.Select Set All Lists Off/On then press E/yes to toggle each setting.MANAGING FULL DATABASEPress Menu then scroll to Manage Full Database and press E/yes.Scroll to the options below and press E/yes.
50Review Avoids – You can review all Systems, Departments, and Channels that are avoided and stop avoiding each one. Note: The Database must be enabled for scan to review Avoids.Scroll to each System, Department, or Channel and press E/yes to stop avoiding. Temporary Avoids appear reversed in the display -   .Stop All Avoiding – This will stop avoiding all Systems, Departments, and Channels in the Database.At Confirm Delete?, press E/yes or ./no.Information – This will show the database version in the scanner.USING STARTUP KEYSTO USE A STARTUP KEY:1.  Turn the scanner off.2.  Press and hold the number key that corresponds to the startup key when you turn the scanner on.3.  Continue holding the number key until the scanner display shows the number of the startup key congurationWhen you use Startup Conguration, the scanner checks all Favorites Lists and:1.  Favorites whose Startup Key matches the one the user pressed are changed to Monitor Status ON.2.  Favorites whose Startup Key DOES NOT match the one the user pressed are changed to Monitor Status OFF.Caution: If you press the wrong key when you press the power key to set your startup conguration, and that wrong key doesn’t have any Favorites Lists assigned to that key, you will start up your scanner with all systems Avoided-Nothing to Scan.PRIORITY SCANNINGPriority Scan – When the scanner is scanning a Conventional System, it interrupts scanning, based on the Priority Interval and Max Channels settings, to check priority channels for activity. The more channels you have set to priority, the longer the interruption will be. The Favorites List(s) and System(s) containing the priority channel(s) have to be enabled (and not Avoided) or the scanner will display Priority Scan No Channel.Priority ID Scan – This function is similar to conventional priority although there is no interruption during the transmission. Priority is checked in between transmissions, when the scanner is receiving the control channel, and during the channel delay period. The scanner can only look for priority IDs in the trunked system it is currently scanning. Priority DND – The scanner checks priority channels, based on the Priority Interval and Max Channels settings, only when not receiving other conventional channels so there is no interruption in scanning with conventional systems.The highest priority is for channels in System and Department Quick Key 0. The lowest priority is for channels in System and Department Quick Key 99. Priority for priority channels in the same channel Department follows the order in which the channels were created.
51To use Priority Scan, you must rst set your Priority Channels.To use Priority ID Scan, you must also enable Priority ID Scan for each system.To Toggle Priority Modes, press Func then ./no(Pri).PRIORITY SCAN OPTIONSPress Menu then scroll to Priority Scan and press E/yes.Set Priority Set Interval MaxChannels/Pri-ScanSet Priority – Sets the Priority mode. You can also toggle these modes by holding on any channel in scan mode and pressing Func then ./no(Pri).Off - The Priority feature is off. Priority DND - The scanner checks Priority channels only when not receiving other conventional channels.PRI appears in the display reversed -  .Priority Scan - The scanner checks conventional priority channels.PRI appears in the display -    .Set Interval – This sets (in seconds) how often the scanner will check the priority channels.1-10 sec.MaxChannels/Pri-Scan – This sets the maximum number of priority channels that are scanned during one priority scan interrupt. If there are more priority channels than the value you select, the channels are divided into more than one group and the scanner scans each group in turn. Example: If you set the maximum channels to 20 and there are 100 priority channels, the scanner checks those 100 channels in groups of 20 and takes a total of 5 intervals to complete the priority scan. 1-100SCANNING BY ASSIGNING QUICK KEYSWith previous scanners, you selected banks to scan. With this scanner, you select Favorites List, and Systems, and Departments to scan by assigning Quick Keys to them. See also Understanding Quick Keys.Scanning is performed with a mixture of FLQK, SQK, and DQK order. The scanner will not scan all Systems in one Favorites List and then move to the next List. For each Favorites List, starting with 0, the scanner will scan each 0 SQK in FLQK order and then move to the next set of SQKs for each list.   Example:FLQK 0, SQK 0; FLQK 1, SQK 0…. FLQK 98, SQK 99; FLQK 99, SQK, 99. Systems with the same quick key are scanned in order of creation.The Database is scanned next, in order of creation. Then, Systems with no quick key (including created Quick Save Systems) are scanned and in order of creation. Departments within Systems are also scanned the same as Systems.Conventional Channels within Systems are also scanned in order of creation.IDs are not really scanned. The scanner checks for any activity in the trunking system and:
52•  Will display all IDs when ID Search mode is set to On. •  Will display only programmed IDs when ID Search mode is set to Off.Next, any Custom Searches (enabled for Search with Scan) are scanned in order.Then, the scanner scans the Close Call ‘Hits with Scan’ system (if Unavoided). This is a system that automatically stores the frequencies found by Close Call. If the ‘Hits with Scan’ system has no frequencies, the scanner will not scan the system.The scanner scans a system for the duration you set using the System Hold Time option. For trunked systems, the scanner moves to the next system after the hold time expires, the current transmission ends, and the channel delay expires. Conventional systems operate similarly, but all (Unavoided) channels are scanned at least one time regardless of the hold time setting.Scanning Checklist:1.  You must enable at least one Favorites List or the Full Database in Select Lists to Monitor.2.  Favorites Lists, or Systems, or Departments with Quick Keys assigned to them, must be enabled with quick keys or through Manage Quick Key Status for Favorite Lists or Systems.3.  Service Types required for channels must be set to On.Any Favorites List not assigned to a quick key, not Avoided, and set to On in Select – to Monitor will be scanned.Any Departments not assigned to a quick key and not Avoided will be scanned.Any System not assigned to a quick key and not Avoided, will be scanned.ScanningDirectionSystemNameFavorites List NameTimeandDateQuick Key forFavorites ListQuick Key forSystemDepartment  NameScan ModeChannelNameFunction Tag Frequency CTCSS/DCS/NACSignal StrengthScan Receive
53System Hold Site HoldUnit ID Display - Channel Hold Search with Scan - Frequency HoldChange Direction or Resume Scan Turn the Scroll Control.SELECTING QUICK KEYS Select a Favorites List Quick Key – Press the number key(s) assigned to the Favorites List then press E/yes. Example: 00, E/yes to enable or disable List 0.Select a System Quick Key in the Current List – Press ./no, then the number key (2 digits) assigned to the System. Example: ./no, 03, E/yes to enable or disable System 3.Select a Department Quick Key in the current List – Press ./no twice, then the number key (2 digits) assigned to the Department.Example: ./no twice, 07, E/yes to enable or disable Department 7.
54Select a System Quick Key in a Different List – Press the number key(s) assigned to the Favorites List then ./no, then the number key (2 digits) assigned to the System then E/yes.Example: 00, ./no, 04, E/yes to enable or disable List 0, System 4.TOGGLE DISPLAY MODESHold on any channel and press Func then 9(DISP). Press Channel to resume.In BCD536HP, you can turn 3-Line Display on and off.In BCD436HP, you can turn on Disp. Unit ID on and off. TOGGLE ID SCAN OR ID SEARCH While scanning each Trunked System, press Func then E/yes.SELECT SERVICE TYPES (BCD536HP) Press Serv.(BCD436HP) Press Func then Zip/Services. Scroll to each Service Type and press E/yes to enable or disable.HOLDINGChannel HoldPress Channel to hold on a Channel. Scroll to channels. Press Channel to release Hold mode. 3-Line Display O3-Line Display On
55Department HoldPress Dept to pause then hold on any Department.Double press Dept to hold without a pause.Press Dept then quickly scroll to the Department in pause mode.Double press Dept to release Department hold. Site HoldPress Func then Dept to hold on any Site.Press Func then Dept to release Site hold.Press Dept then rotate the scroll control to select a Site. System HoldPress System to pause then hold on any System.Double press System to hold without a pause.Press System then quickly scroll to the System in pause mode.Double press System to release System hold.REPLAY THE LAST TRANSMISSIONS While scanning, press Replay.Press Channel to pause/resume replay.Turn the Scroll Control to select recordings.START/STOP RECORDING While scanning, press Func then Replay.Note: Resets to Off when you turn off the scanner.ADVANCED CHANNEL MENUWhile the channel is in the display, press E/yes.Edit Current Channel - See Channel Options.Add to Favorites List - Press E/yes or ./no.At Select Favorites List, scroll to the Favorites List and press E/yes. Save Sub Audio/P25 NAC - CTCSS Tone or DCS/NAC Code (blinking)At Are you sure?, press E/yes.Save Talk Group ID - Unknown Talk Group ID with ID SearchAt Are you sure?, press E/yes or .No.At Select Department, scroll to the Department and press E/yes.Save Unit ID - Unknown Unit IDAt Are you sure?, press E/yes or .No.STORE A SEARCH FREQUENCY SEARCH WITH SCANPress E/yes.Then see Storing Frequencies.Adding Systems From the DatabasePress E/yes to store a frequency.
56ATTENUATIONChannel Attenuation - Press Channel to hold on the channel and press Func then 4(ATT) to toggle attenuation. Global Attenuation - Press Channel to hold on any channel then press Func then press and hold 4(ATT) to toggle global attenuation. MODULATIONConventional Channel ModulationPress Channel to hold on the channel.Press Func then Channel(MOD) to toggle modulation. Press Channel to release hold mode.Site ModulationPress Func then Dept to hold on the Site.Press Channel to hold on any channel.Press Func then Channel(MOD) to toggle modulation. Press Channel to release hold mode.Press Func then Dept to release Site hold mode.INTERMEDIATE FREQUENCY EXCHANGEPress Channel to hold on the channel.Press Func then 7(IFX) to toggle on or off.REPEATER FREQUENCY CONVENTIONAL CHANNELPress Channel to hold on the channel.Press Func then press and hold 8(REV).CHANNEL VOLUME OFFSETPress Channel to hold on the channel. Press Func then press 0(LVL) to toggle.AVOIDING CHANNELS, DEPARTMENTS, SITES, AND SYSTEMSAvoids are common to every System in the Favorites List.Temporary Avoids cancel when you cycle power. See also Review Avoids.Channel Avoid When the Channel is in the display or in Channel Hold mode:To Temporary Avoid, press Avoid once.To Permanent Avoid, press twice when the channel is in the display or in Channel Hold mode.Department AvoidPress Dept then Avoid once to Temporary Avoid.Press Avoid twice to Permanent Avoid.Site Avoid When the Site is in the display or in Site Hold mode (Func then Dept):
57To Temporary Avoid, press Dept then quickly press Avoid. To Permanent Avoid, press Dept then quickly press Avoid twice.To Stop Avoiding, press Dept then Avoid once.Press Func then Dept to release Site hold.System AvoidPress System then Avoid once to Temporary Avoid.Press Avoid twice to Permanent Avoid.CHANGE YOUR LOCATION  (BCD536HP) Press the Zip button.(BCD436HP) Press Zip/Services.Select your Country, and enter a zip/postal code. See also Set Your Location.SET THE RANGE (BCD536HP) Press the Rang button.Enter new range using the numeric keys and press E/yes to save.(BCD436HP) See Set Range. See also Understanding Range and Understanding Location Control.DIRECT FREQUENCY/TGID ENTRYPress Channel to hold on any Channel.Enter the Frequency/TGID and press E/yes. Press Channel to release hold.USING NUMBER TAGS If two Favorites Lists have the same number tag, they will be selected in sequence. The rst time you select the number tag, the scanner will go to the rst Favorites List assigned to that number tag; if you select the same number tag again, it will go to the 2nd Favorites List assigned to that number tag, and so on. The same rule applies to System and Channel number tags.View Number Tags BCD436HP - Number Tag is always displayed in Scan Hold mode.BCD536HP - Press Func in Scan Hold mode..Go To Number Tag Press Channel to hold on any channel.Favorite Number TagSystem Number Tag Channel Number Tag
58Enter the Favorites number tag, ./no, then the System number tag, ./no, then the Channel number tag and press Channel.Examples:1.01.36 to go to Channel 36 in System 01 in Favorites List 1..01.36 to go to Channel 36 in System 01 in current Favorites List. ..36 to go to Channel 36 in current System. CLOSE CALL MODESTo toggle CC Off, CC DND, or CC Pri:(BCD536HP) Press SQ (   ). (BCD436HP) Hold on any channel and press Func then Avoid(   ).Close Call Hit See Using Close Call.PRIORITY MODES Press Func then ./no(PRI) to toggle Priority mode Off, DND, or On.Weather Alert Priority Press Channel to hold on any channel. Press Func then 6(WX) to toggle on or off.CUSTOM SEARCH BY SEARCH KEY Press Channel to hold on any channel.Press Func then 1(SRCH1), 2(SRCH2), or 3(SRCH3), to start a Custom Search assigned to a Search Key.CLOSE CALL ONLY (BCD536HP) Press and hold SQ (   ).(BCD436HP) Press Func then press and hold Avoid  (   ).WEATHER SCANPress Channel to hold on any channel.Press Func then press and hold 6(WX).System Number TagFavorite Number TagChannel Number Tag
59TONEOUT STANDBY/SEARCH (BCD536HP Only)  Press Func then SQ. (Push F+FTO)(BCD436HP) Assign Tone-Out Standby/Search to a Search Key.REVIEW AVOIDSDatabase Avoids. Press Menu and scroll to Manage Full Database.Scroll to the following:Review Avoids - Scroll to each channel, department, site, or system and press E/yes to Stop Avoiding. Temporary Avoids appear reversed in the display -   .Stop All Avoiding - At Confirm?, press E/yes or ./no.Favorites List Avoids. Press Menu and scroll to Manage Favorites.Scroll to the Favorites List and press E/yes.Scroll to the following:Review Avoids - Scroll to each channel, department, site, or system and press E/yes to Stop Avoiding.  Temporary Avoids appear reversed in the display -   .Stop All Avoiding - At Confirm? press E/yes or ./no.ID Avoids. Press Menu and scroll to Manage Favorites.Scroll to the Favorites List and press E/yes.Scroll to Review/Edit System and press E/yes.Scroll to the System and press E/yes.Scroll to Edit Sys Options and press E/yes.Scroll to the following:Review ID Avoids - Scroll to each ID and press E/yes to Stop Avoiding.Clear All ID Avoids - At Conrm? press E/yes or ./no.   Clear All Avoids for Site or Department – Press Channel to hold on any System. Press and hold Avoid.QUICK SEARCHPress Func then E/yes to start Quick Search at the current frequency. P25 ADJUSTMENT MODE(BCD536HP) Press Func then Scroll Control knob. Press Func then Scroll Control knob to exit. (BCD436HP) Press Scroll Control knob then Func then Scroll Control knob. Press Scroll Control knob to exit.APCO Decode Error RateThreshold LevelP25 Condition ModeThreshold Voltage
60Set the P25 Threshold mode to Manual in Site Options or System Options for a Conventional channel. Press Func then Dept to hold on a Site or Channel to hold on a digital Channel.The rst line on the display now shows the digital error rate and the decode threshold setting (0-20). The second line on the display shows the decode threshold levels for the site.Allow the scanner to monitor the site or channel for several minutes. The error rate should drop for each transmission and the threshold levels should automatically adjust to a more optimal setting. Then, once the threshold level settles to a stable setting, make a note of the value. This is the site’s or channel’s optimum decode threshold.Press Func and rotate the Scroll Control to set the MAN decode threshold start level to a setting that most closely matches the system’s optimum decode threshold. Whatever you set at this point will be remembered for this site as the starting point for the auto-tuning function for subsequent transmission on  site. See also P25 Threshold Level.USING A GPSLOCATIONBASED SCANNINGYou can connect the scanner to a compatible GPS device and set the scanner to automatically Avoid and Unavoid Departments and Sites based on your current location. This frees you from having to manually enable and disable Departments and Sites as you change locations.For the BCD436HP, use the 4-pin mini plug to connect to the scanner using a NMEA compatible GPS device. The BCD536HP has a 9-pin RS232 male serial connector and you should select a baud rate of (4800 bps) for the serial port.A good application of this feature would be to set the longitude and latitude for each multi-site system transmitter as usually you can receive at least a handful in any given location. Set the range to around 30 miles and the scanner will automatically Avoid or Unavoid Sites when in and out of range. It may also be relevant to set different locations/ranges for the Departments within the site.You can nd the physical location of antennas using the databases available at Radio Reference or the FCCs Antenna Structure Registration site.Both sites list the latitude, longitude, and height of the antenna and both sites can map the exact location for you. Once the scanner completes the initial GPS review, if you move into or out of an area covered by a Site/Department, the scanner will Avoid and Unavoid Sites and Departments according to Range settings for the scanner and Sites/Departments.If you cycle power, all Sites/Departments are Unavoided until the scanner reacquires the GPS signal and completes the initial GPS review. Note: If you unplug your GPS device or it loses reception to satellites, the scanner will use the last known location as the current location.See also Set Location to set your Location, Range, and relevant GPS options.See also Understanding Location Control and Understanding Range.All Sites/Departments with locations set and not within range of your current location will be temporarily Avoided.
61DISCOVERY MODETrunking Discovery mode allows you to monitor a trunked radio system, logging system channel activity and recording the audio for channels. Conventional Discovery mode lets you monitor a range of frequencies, logging frequencies with activity and recording the audio for frequencies that are not already known to be in use in your area so that you can more easily identify the users. This includes frequencies used conventionally as well as in trunked radio systems. In both modes, you also have the option to compare hits to the Database and log all hits or just new hits. If you use the Auto Store option, Discovery will create a new Trunking System for IDs found for each Session or will create a new Conventional System for frequencies found for each Session. You can create and save several sessions with different settings. Every time you start a session you create a Run that can later be reviewed in the scanner or the Sentinel software.NEW SESSIONPress Menu then scroll to Discovery and press E/yes.Scroll to Trunking Discovery or Conventional Discovery and press E/yes.Scroll to New Session and press E/yes. Conventional DiscoveryInput Session Name - Enter the Name and press E/yes. See Data Naming.Trunking DiscoveryInput System Name - Enter the rst few relevant letters of the system and press E/yes. See Data Naming.Note: The System must be enabled for scan to input system name.Select System - Scroll to the System and press E/yes.Select Site - Scroll to the Site and press E/yes.Input Session Name - Enter the Name and press E/yes. See Data Naming.SESSION OPTIONSPress Menu then scroll to Discovery and press E/yes.Scroll to Trunking/Conventional Discovery and press E/yes.Scroll to the Discovery Session and press E/yes.Start Discovery Set Compare to databaseEdit Session Name Set Record DurationSet Limit Frequencies Set Time-Out TimerSet Modulation System InformationSet Step Set Auto StoreSet Delay Delete SessionSet Logging Change System
62Start DiscoveryThis starts the Discovery Session.Press Menu to stop and review the Run information. See Review Discovery.Press Avoid to Avoid a hit.Press Func then System to exit.Edit Session NameThis allows you to name a Session.See Data Naming.Set Limit Frequencies (Conventional Only)This sets the lower and upper frequencies for conventional discovery session.Set Lower Limit Enter the lower limit.Set Upper Limit Enter the upper limit.Set Modulation (Conventional Only)This sets the modulation for conventional discovery session. Auto, AM, FM, NFM, WFM, or FMB (FM Broadcast)Set Step (Conventional Only)This sets the step size for conventional discovery session. Auto, 5, 6.25, 7.5, 8.33, 10, 12.5, 15, 20, 25, 50, or 100 kHzSet DelayThis sets the Delay when monitoring a site or frequencies. 0, 1, 2, 3, 4, or 5 sec.Set LoggingThis will log all hits or just new hits.All or New OnlySet Compare to DatabaseSelect On to compare hits against the channels already in the Database. Only new channels will have audio recorded (if enabled). Select Off to treat all hits as new channels.On or OffSet Record DurationThis sets how much audio will be recorded for each new channel. None, 30, 60, 90, 120, 150, 180, 300, or 600 sec.Set Time-Out TimerThis is used to keep a stuck channel from stealing the whole Run in a session.Off, 10, 30, or 60 sec.System Information (Trunking Only)This will give you where it came from, (Full Database or Favorites List), the System Type, (Motorola, P25, etc.), and the System used for the Discovery Session.
63Set Auto StoreThis turns Auto Store on and will create a System called Conventional or Trunking Discovery.On or OffDelete SessionThis deletes the session.At Confirm Delete? Press E/yes or ./no.Change System (Trunking Only)This allows you to create or change the System used and change the Site used for the session.Input System NamePress E/yes to Skip if System is saved.See Data Naming.Select SystemSelect the System to use for the session.Select SiteSelect the Site to use for the session.REVIEW DISCOVERYIn Review Discovery mode, you can review the results of discovery mode runs, resume runs, or restart saved discovery sessions.Press Menu then scroll to Discovery and press E/yes.Scroll to Review Discovery and press E/yes.Scroll to Trunking/Conventional Discovery Results and press E/yes.Scroll to select each Run.Review Run ResultsSummary List by each frequency.Detail - List by each hit.Restart this Run. Delete all log les.Restart? Press E/yes or ./no. Resume this Run Continue without deleting log les.Resume? Press E/yes or ./no.Delete this RunAt Confirm Delete?, press E/yes or ./no.Rename this RunConventional Discovery
64See Data Naming.Run InformationShows the Session settings.SEARCH/CLOSE CALL OPTIONSThese are the settings you should look at before you perform a Quick Search, or Close Call Search.Press Menu. Scroll to Srch/CloCall Opt and press E/yes.Scroll to the options below and press E/yes. Freq Avoids Set Delay Time P25 Waiting TimeBroadcast Screen Set Attenuator P25 Threshold ModeRepeater Find Set Audio AGC P25 Threshold LevelFreq Avoids – This allows you to review Avoided Frequencies or Stop Avoiding all Frequencies for Searching and Close Call search. Temporary Avoids appear reversed in the display -   .Stop All Avoiding. See also Search Avoids.At Confirm? Press E/yes or ./no.Rvw Search AvoidScroll to Frequency and press E/yes to Stop Avoiding. Broadcast Screen – Automatically ignores transmissions that are on common broadcasts, paging systems, and other annoyance radio sources during Custom Search, Quick Search, or Close Call Search. The default setting is Pager On.Set All Band On/Off. Turns Broadcast Screen On or Off for All Bands.Set Each BandScroll to each Band and press E/yes to enable or disable.Program BandBand 0-9 Select for each Close Call Band and other searches.Set Lower Limit - Input the lower frequency limit.Set Upper Limit  - Input the upper frequency limit.Press Menu to return and repeat for each band as needed.Repeater Find – Sets whether the scanner tries to tune to a repeater output frequency when it detects a transmission on a repeater input frequency, in Search and Close Call modes. Turning this feature on can let you hear both sides of the conversation on the output frequency. The default setting is Off.On or OffSet Delay Time – Determines how long the scanner waits after a transmission ends before resuming Quick Search and Close Call Search operations. A negative delay will force a resume after that number of seconds. The default setting is 2 seconds.   -10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 sec.
65Set Attenuator – This controls the attenuator for Quick Search, and Close Call operations by about 20dB. The default setting is Off.On or OffSee also Search Attenuation.Set Audio AGC – This allows you to turn AGC (Automatic Gain Control) on or off for Quick Search and Close Call modes. The default settings are Off. Analog. Press E/yes to toggle On or Off.Digital. Press E/yes to toggle On or Off. P25 Waiting Time – This setting gives the scanner time to determine if frequencies have digital or analog transmissions. During this time, the scanner will evaluate the received signal and, if it detects digital data, will open squelch immediately. If digital is not detected before the delay expires, the scanner will open squelch at the end of this delay. This is to prevent “false decode” problems. The default setting is 400 ms.0 to 1000 msNote: Any analog transmissions will lose the rst part of the transmission, up to the wait time you set here.P25 Threshold Mode – The default setting is Auto.Auto. Automatically sets the decode threshold based on the received signal.Manual.  Allows you to manually set the threshold in threshold setting mode or using the P25 Threshold Level setting.Default. Sets the scanner to the default threshold of 8, Auto.P25 Threshold Level – The default setting is 8.0 to 20SEARCH OPTIONSPress Menu. Scroll to Search for... and press E/yes.Scroll to the options below and press E/yes.Custom Search Set Search KeyEdit Custom Search with ScanIMPORTANT! There are many options and setting in Search/Close Call Options that affect and compliment the settings for searching. Please review those rst.EDIT CUSTOMYou can edit the 10 Custom Search ranges. The default custom search range names appear as Custom 1, Custom 2, and so on.Custom 0-9. Select for each Custom Search.Edit Name. See Data Naming.Edit Srch LimitSet Lower Limit. Enter the lower limit.Set Upper Limit. Enter the upper limit.Set Delay Time
66   -10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 sec.Set ModulationAuto, AM, NFM, FM, WFM, or FMB (Broadcast)Set AttenuatorOn or OffSet StepAuto, 5, 6.25, 7.5, 8.33, 10, 12.5, 15, 20, 25, 50, or 100 kHz Set Audio AGCAnalog - Press E/yes to toggle On or Off.Digital - Press E/yes to toggle On or Off. P25 Waiting Time0 to 1000 msP25 Threshold ModeAuto, Manual, DefaultP25 Threshold Level0 to 20Search with Scan. See also Select Lists to Monitor and Search with Scan.Set AvoidStop Avoiding, Temporary Avoid, or Permanent AvoidSet Hold Time. Sets how long to search when scanning.Enter the hold time (0-255 sec.) and press E/yes to save.SET SEARCH KEYThe scanner has three search keys that you can assign to a search range. The search keys are number keys 1, 2, and 3. This allows you to start a Custom, Tone-Out, or Close Call Search without having to go into the menus.Search Key 1-3. Select a search for each Search Key. . (nothing assigned), Custom Search 0-9, Tone-Out, or Close Call. SEARCH WITH SCANThis enables Custom Searches in Scan mode.See also Select Lists to Monitor and Edit Custom Search.Set System AvoidStop Avoiding, Temporary, or Permenant Avoid. QUICK SEARCHAllows you to start searching at the displayed frequency, or enter a frequency and start searching from that frequency in hold modes.Quick Search will search all the way up to 1300 MHz or all the way down to 25 MHz then start over. To Start a Quick Search from the Displayed Frequency:Press Channel to hold on the channel or frequency. Press Func then E/yes. At Quick Search? Press E/yes.
67Press Channel again to release hold mode and start searching.To Start a Quick Search from a New Frequency:Press Channel to hold on any channel or frequency. Enter the new frequency then press Channel to set the new starting frequency. Press Channel again to release hold mode and start searching.Press Channel to hold on any channel or frequency. Enter the new frequency you wish to start at then press Channel to set the new starting frequency. Press Channel again to release hold mode and start searching. CUSTOM SEARCHAllows you to search the scanners 10 programmed frequency ranges. See also Edit Custom Search.Press Menu. Scroll to Search for... and press E/yes.Scroll to Custom Search and press E/yes. See also Set Search Key.Change Direction or Resume SearchTurn the Scroll Control.Select Custom Search BandsPress the number keys to enable or disable each Custom Search band.HoldingFrequency Hold. Press Channel to hold on a Frequency. Scroll to frequencies. Press Channel to release hold. Avoiding FrequenciesTemporary Avoids cancel when you cycle power.Frequency Avoid - Press Avoid once to Temporary Avoid.Range number currently being searchedSearch range nameSearching Direction
68Press quickly to toggle Permanent Avoid and Stop Avoiding when the the scanner stays in a frequency or in Search Hold mode.Review Avoids - Press Channel to hold on any Frequency. Press Func then Avoid. Scroll to each frequency and press E/yes to Stop Avoiding. Temporary Avoids appear reversed - T .Stop All Avoiding - Press Channel to hold on any Frequency. Press and hold Avoid. The scanner displays Search Frequencies All Unavoided.See also Freq Avoids.Attenuation Band Attenuation. Press Func then 4(ATT) for each band.Global Attenuation. Press Channel to hold on any frequency then press and hold Func then 4(ATT) to toggle global attenuation.Modulation Press Func then Channel(MOD) for each band.Direct Frequency EntryPress Channel to hold on any frequency. Enter the frequency and press Channel. Press Channel to release hold. Frequency Intermediate ExchangePress Channel to hold on any frequency. Press Func then 7(IFX) to toggle on or off.Repeater FrequencyPress Channel to hold on any frequency. Press Func then press and hold 8(REV).Replay the Last TransmissionsWhile searching, press Replay.Press Channel to pause/resume replay.Turn the Scroll Control to select recordings.Start/Stop Recording While searching, press Func then Replay.Note: Resets to Off when you turn off the scanner.Storing FrequenciesDisplayed Frequency into a Quick Save Department – Press E/yes. You will see Quick Frequency Save in the display then press E/yes. The scanner stores the frequency into the Quick Save Department in the Quick Save System.Displayed Frequency into an Existing Department – Press E/yes. You will see Saving to Quick Dept in the display then press ./no.At Saving Channel to scroll to the Favorites List and press E/yes. At Select System scroll to the System and press E/yes.At Select Department scroll to the and press E/yes.
69After storing the frequency, you will be at the Edit Channel menu to complete the settings for the new channel.If you don’t want to edit the channel settings or are done editing the channel, press Avoid to return to searching.Search MenuPress Func then Menu.Close Call ModesTo toggle CC Off, CC Pri, or CC DND: (BCD536HP) Press SQ(   ). (BCD436HP) Press Func then Avoid(   ).Weather Alert Priority ModePress Channel to hold on any channel.Press Func then 6(WX) to toggle on or off.CLOSE CALLYour scanner’s Close Call feature lets you set the scanner so it detects, alerts you to, and displays the frequency of a nearby strong radio transmission. You can set the scanner so the Close Call feature checks for a Close Call hit every 2 seconds in the background while you are scanning, searching, listening to the weather frequency, etc. or use Close Call Only mode. Close Call ‘Do-Not-Disturb’ will only check for close call signals when you are not receiving transmissions. You can also select the frequency band(s) to look for transmissions. When the scanner detects a Close Call hit, it alerts you according to the alert settings. ‘Hits with Scan’ is a special system that automatically stores the last 10 Close Call hits until you cycle power. The Close Call feature works well for locating the source of strong local transmissions such as mobile and handheld two-way radios in areas with no other strong transmission sources. Performance is increased with higher transmit power, a receive antenna tuned to the target band, and a low background RF level.The Close Call feature works better with some types of transmissions than others.It might not correctly display frequency information for transmitters using a highly directional antenna (such as an amateur radio beam antenna) or if there are many transmitters operating at the same time in the same area. CLOSE CALL OPTIONSImportant! There are many options and settings in Search/Close Call Options that affect and compliment the settings for Close Call. Please review those rst.Note: Close Call does not operate in Weather Scan or Tone-Out Standby/Search.Press Menu. Scroll to Close Call and press E/yes. Scroll to the options below and press E/yes.Close Call Only Set CC BandsHits with Scan Set CC Alert
70Set CC ModeClose Call OnlyThis setting puts the scanner in Close Call Only mode.See also Using Close Call.You can also toggle these modes by:BCD436HP: Holding on any channel and pressing Func then Avoid ( ).BCD536HP: Pressing SQ ( ).Hits with ScanThis is a special system that automatically stores the last 10 close call hits and allows you to scan them. Accessible only in the Close Call menu, the system has to be Unavoided to view while scanning (default is Permanent Avoid). The scanner will delete the frequencies in this system when you turn the power off. Set AvoidStop Avoiding, Temporary, or Permanent AvoidSet Hold Time. Sets how long to search when scanning.Enter the hold time (0-255 sec.) and press E/yes to save.Set CC Mode Selects the Close Call mode when scanning or searching.Off. Close Call is turned off.CC DND. Close Call checks for frequencies every two seconds when the scanner is not receiving a transmission.CC Priority. Close Call checks for frequencies every two seconds.You can also toggle these modes by:(BCD536HP) Pressing SQ (   ). (BCD436HP) Holding on any channel and pressing Func then Avoid (  ). Set CC Bands Lets you select the Close Call bands to be searched.Scroll to each Band and press E/yes to toggle On or Off.Press Menu to return.VHF Low 1 - 25-54 MHz VHF High2 - 225-320 MHzVHF Low 2 - 54-108 MHz UHF - 320-512 MHzAir Band - 108-137 MHz 800MHz+ - 758-960, 1240-1300 MHzVHF High1 - 137-225 MHz (Cellular frequencies not scanned)Set CC AlertThis allows you to set an Alert Tone, Alert Light, and sets the Pause time for Close Call when you receive a hit. Set Alert ToneAlert 1-9 or Off.
71Set LevelLevel 1-15 or Auto (the master volume level). Set Alert LightSet Color Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White.Set PatternOn, Slow Blink, or Fast Blink.Set CC Pause3, 5, 10, 15, 30, 45, 60, sec. or Innite.Close Call Only Mode(BCD536HP) Press and hold SQ (   ).(BCD436HP) Press Channel to hold on any channel/frequency.Press Func then press and hold Avoid (   ) . See also Set Search Key.You will see activity on the 7 bands in the display. Bands with an * (asterisk) under them are turned off.When the scanner detects a Close Call signal, CC Found! and Press Any Key display for the length of time set in Close Call Pause. Toggle Close Call BandsPress the number keys to enable or disable each Close Call band.Cancel a HitTurn the Scroll Control. Holding on a HitPress System, Department, or Channel to hold on the Close Call Hit. Press Channel to cancel hold. Turn the Scroll Control to start Quick Search.View Last HitPress System, Department, or Channel to recall the last hit. Press Channel to cancel hold.Avoiding Hits Temporary Avoids cancel when you cycle power.Press Avoid once to Temporary Avoid.Close Call Only Mode
72Press quickly to toggle Permanent Avoid and Stop Avoiding when the frequency is in the display or in Search Hold mode.Review Avoids. Press Channel to hold on any Frequency. Press Func then Avoid. Scroll to each frequency and press E/yes to Stop Avoiding. Temporary Avoids appear reversed in the display - T .Clear All Avoids - Press Channel to hold on any Frequency. Press and hold Avoid. The scanner displays Search Frequencies All Unavoided.Close Call HitAttenuation Press Func then 4(ATT) for all bands.Modulation Press Func then Channel(MOD) for all bands.Intermediate Frequency ExchangePress Channel to hold on any frequency. Press Func then 7(IFX) to toggle on or off.Repeater FrequencyPress Channel to hold on any frequency. Press Func then press and hold 8(REV).Replay the Last TransmissionsPress Replay.Press Channel to pause/resume replay.Turn the Scroll Control to select recordings.Start/Stop RecordingPress Func then Replay.Note: Resets to Off when you turn off the scanner.StoringDisplayed Frequency into a Quick Save Department. Press E/yes. You will see Saving to Quick Save Department in the display then press E/yes. The scanner stores the frequency into the Quick Save Department.Displayed Frequency into an Existing Department Press E/yes. You will see Saving to Quick Save Department in the display, then press ./no.At Select Department, scroll to the department where you want to store the frequency and press E/yes.
73After storing the frequency, you will be at the Edit Channel menu to complete the settings for the new channel.If you don’t want to edit the channel settings or are done editing the channel, press Avoid to return to searching.Close Call MenuPress Func then Menu.WEATHER OPERATIONWEATHER OPTIONSPress Menu. Scroll to WX Operation and press E/yes.Scroll to the options below and press E/yes.Set Delay Time WX Alt PrioritySet Attenuator Weather ScanSet Audio AGC Weather AlertProgram SAME Review WX AlertsSet Delay TimeSets the number of seconds the scanner should wait after a transmission stops before moving on to the next channel during weather scan. A negative delay will force a resume after that number of seconds. The default setting is 2 seconds.   -10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 sec.Set Attenuator Sets the attenuator (20 dB) for weather operation. The default setting is Off.On or OffNote: You can also toggle attenuation for weather scan by pressing Func then 4(ATT). Set Audio AGC This allows you to turn AGC (Automatic Gain Control) on or off for Weather operations. The default setting is Off.Analog - Press E/yes to toggle On or Off.Program SAMESAME (Specic Area Messaging System) is a system developed by the National Weather Service to reduce the number of alerts received by consumers by allowing them to hear alerts only for the county(ies) they are interested in. Each alert contains information about the type and severity of the alert, as well as the specic geographic locations affected by the alert. To receive SAME alerts, you can program up to 5 groups of 8 FIPS codes (40 codes) into the scanners memory.
74To nd the FIPS codes for your scanner call the NWS toll free at 1-888-697-7263 (follow the instructions you hear) or see FIP codes for the United States and its Possessions.SAME 0-4 Select for each SAME group.Edit Name. See Data Naming.Edit CountyCode 1-8. Select for each FIP code.Enter the FIPS code and press E/yes to save.Weather Alert Priority Turning the weather alert priority feature on allows the scanner to check the weather channels every 5 seconds for a 1050 Hz weather alert signal and still scan or search. If you should receive an alert, you will hear a loud warbling then the weather channel audio.On or OffNote: You can also toggle weather alert priority in scan or search modes by holding on any channel and pressing Func then 6(wx).Weather ScanPress Channel to hold on any channel/frequency. Press Func then press and hold 6(WX).The scanner starts scanning the preprogrammed weather frequencies and stops on the rst good signal. If the signal is lost, the scanner resumes searching for another weather transmission.Change ChannelTurn the Scroll Control.Attenuation Press Func then 4(ATT).Intermediate Frequency ExchangePress Channel to hold on any frequency. Press Func then 7(IFX) to toggle on or off.Replay the Last TransmissionsRecording starts when the scanner receives an Alert in Weather Alert.Press Replay.Press Channel to pause/resume replay.Turn the Scroll Control to select recordings.Quick SearchPress Func then E/yes to start Quick Search at the current frequency. Weather MenuPress Func then Menu.
75WEATHER ALERT This setting turns on weather alert and determines which types of signals will trigger an alert. See also Program SAME.Press Channel to hold on any channel/frequency.Press Func and then press and hold 6(WX). Press Func then Menu.Scroll to Weather Alert and press E/yes.Alert Only - The scanner will scan all the weather channels and immediately sound a weather alert siren when it detects the 1050 Hz weather alert tone. Press any key to stop the siren which opens the squelch and the scanner remains on the weather channel.SAME 0-4 - The scanner sounds a weather alert siren for any programmed county(ies). The scanner displays warning level as “Warning WX”, “Watch WX” or “Advisory WX” and it displays decoded Event Code.When an alert is received, press any key to listen to the alert.All FIPS - The scanner sounds a weather alert siren for any county.The scanner displays warning level as “Warning WX,” “Watch WX” or “Advisory WX” and it displays decoded Event Code.When an alert is received, press any key to listen to the alert.The scanner will mute and scan only the weather channels. WARNING! If you receive an alert it will be at FULL volume. Review WX Alerts Replay and review WX/SAME alert event results. The scanner drops these alert events after the alert time expires.FIRE TONEOUTFire Tone-Out will monitor up to 32 different channels for paging tones (two-tone sequential, single tone, and group tone). Weather AlertWeather Warning
76Tone-Out Standby Mode is used if you use programmed tones.Tone-Out Search Mode is used if you don’t know the tones.All tone-outs (channels) that have the same frequency (and modulation and attenuation) as the one you select will also (and only) be monitored so you can monitor up to 32 tone-out channels for one frequency.In this case, the scanner displays each tone-out channel for two seconds. It does not scan them; tone-out monitors the frequency for all tone-out channels with the same frequency. Regardless of the current display, the scanner will alert on any received tone out that matches a stored setting (channel) for the frequency.Note: Tone-Out Search Mode will not display each Tone-Out channel for two seconds, even when multiple channels have the same frequency, modulation and attenuator settings with other channels. TONEOUT SETUP Press Menu. Scroll to Tone-Out for... and press E/yes.Scroll to Tone-Out Setup and press E/yes.Scroll to Tone-Out (0-31) and press E/yes.Note: Close Call DND/Pri and Weather Alert Priority do not operate in this mode.Edit Name Start Delay TimeSet Frequency Set AlertSet Tone Set Audio AGCEdit NameSee Data Naming.Set FrequencyEdit Frequency Enter the frequency and press E/yes.Set ModulationAuto, NFM, FMSet AttenuatorOn or OffSet ToneEdit Tone A and press E/yes. Enter the tone and press E/yes to save.Edit Tone B and press E/yes. Enter the tone and press E/yes to save.Press Menu to return.For two-tone pages, enter the tones (in Hz) for tone A and tone B.For one-tone pages using short tones between 1.25 and 3.75 seconds, enter tone for tone A, and 0 for tone B.For long-tone pages, such as group pages of more than 3.75 seconds, enter 0 for tone A, and the tone for B.To search for tones, leave the tones for A and B at 0.
77Set Delay Time0 - the scanner resumes standby as soon as the carrier drops after a page.1, 2, 3, 4, 5, 10, 30 - (seconds): the scanner resumes standby mode after the carrier drops and the selected time expires.Infinite - you must press Hold after a page to resume standby mode.Set AlertSet Alert ToneAlert 1-9 or Off.Set LevelLevel 1-15 or Auto (the master volume level). Set Alert LightSet Color Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White.Set PatternOn, Slow Blink, or Fast Blink.Set Audio AGC This allows you to turn AGC (Automatic Gain Control) on or off for Tone-Out operations. The default setting is Off.Analog - Press E/yes to toggle On or Off.FIRE TONEOUT STANDBY/SEARCHPress Menu. Scroll to Tone-Out for... and press E/yes.Scroll to Tone-Out Standby and press E/yes. (BCD536HP Only) press FUNC then SQ.See also Set Search Key.Scroll to monitor a Tone-Out channel (0-31). Press Func then System to exit. Any transmission received on the frequency will not be heard but you will still see the signal strength bars. To monitor a different frequency, scroll to a tone-out (channel) with a different frequency.Tone-Out channel nameTone A and B frequencyTone-Out Standby StatusTone-Out channelTone-Out Standby Mode
78If you press Channel while in Standby/Search mode, the scanner temporarily exits and you will be able to hear any transmissions on that frequency. No alerts sound, even if a tone-out matches one you have programmed in hold mode. Press Channel again to return to Standby/Search mode.If the scanner nds tones in Tone-Out Search mode, you will see Set Found Tone A and B? after you press E/yes to save.Select a Dierent Tone-OutTurn the Scroll Control.Listen to Tone-Out FrequencyPress Channel.AttenuationPress Func then 4(ATT).ModulationPress Func then Channel(MOD).Intermediate Frequency ExchangePress Func then 7(IFX) to toggle on or off.Start/Stop RecordingPress Func then Replay.Note: Resets to Off when you turn off the scanner.Store Found Tones Press E/yes at Save Found Tones?.Tone-Out Menu Press Func then Menu.APPENDIXTROUBLESHOOTINGScan Mode, Nothing to Scan1.  Make sure you Set Your Location to scan the Database.2.  Make sure Favorites Lists are enabled in Set Scan Selection.3.  Make sure Service Types are enabled for the Channels you want to hear.4.  Make sure you have locations programed if Use Location Control is On.5.  Make sure longitude and latitude are N and W (for N America).Tone-Out Search Mode
796.  Make sure Systems/Departments/Channels are not Avoided.7.  Make sure Favorites List/System/Department quick key is enabled.8.  (Search with Scan) Make sure Search with Scan is enabled in Select Lists to Monitor and the Search for Menu and for the Custom Search.Scanning Interrupted1.  Turn off Priority Scan. Change Priority Interval.2.  Turn off Close Call Priority.3.  Turn off Weather Priority.4.  Set Channel Delay longer.5.  Set positive Channel Delay.All Channels Out of Range1.  Increase your range.2.  Turn Location Control off for the Favorites List..DEFAULT BAND COVERAGEFrequency Range Mode Step (kHz) BandLower Upper25.0000 26.9600 AM 5 Petroleum Products & Broadcast Pickup26.9650 27.4050 AM 5 CB Class D Channel27.4100 27.9950 AM 5 Business & Forest Products28.0000 29.6800 NFM 20 10 Meter Amateur Band29.7000 49.9900 NFM 10 VHF Low Band50.0000 53.9800 NFM 60 6 Meter Amateur Band54.0000 71.9500 WFM 50 VHF TV Broadcast 2 – 472.0000 75.9950 FM 5 Intersystem & Astronomy76.0000 87.9950 WFM 50 VHF TV Broadcast 5 – 688.0000 107.9000 FMB 100 FM Broadcast108.0000 136.9916 AM 8.33 Commercial Aircraft137.0000 143.9875 NFM 12.5 Military Land Mobile144.0000 147.9950 NFM 5 2 Meter Amateur Band148.0000 150.7875 NFM 12.5 Military Land Mobile150.8000 161.9950 NFM 5 VHF High Band162.0000 173.9875 NFM 12.5 Federal Government174.0000 215.9500 WFM 50 TV Broadcast 7 – 13216.0000 224.9800 NFM 20 1.25 Meter Amateur Band225.0000 379.9750 AM 25 UHF Aircraft Band380.0000 399.9875 NFM 12.5 Trunked Military Band
80Frequency Range Mode Step (kHz) BandLower Upper400.0000 405.9875 NFM 12.5 Miscellaneous406.0000 419.9875 NFM 12.5 Trunked Federal Government420.0000 449.9875 NFM 12.5 70 cm Amateur Band450.0000 469.9875 NFM 12.5 UHF Standard Band470.0000 512.0000 NFM 12.5 UHF TV Band758.0000 787.99375 NFM 6.25 Public Service Band788.0000 805.99375 NFM 6.25 Public Service Band806.0000 823.9875 NFM 12.5 Public Service Band849.0125 868.9875 NFM 12.5 Public Service Band894.0125 960.0000 NFM 12.5 Public Service Band1240.0000 1300.0000 NFM 25 25 cm Amateur BandWhen you select AUTO for a channel, modulation, or step, the above values are used unless you’ve edited the Band DefaultsSteps can be selected from 5/6.25/7.5/8.33/10/12.5/15/20/25/50/100/AUTO (kHz).Although TV bands are listed, the scanner cannot decode digital TV audio.SERVICE TYPESService Type DescriptionAircraft For civilian aircraft and air trafc control operations most typically in the 118-136 MHz and 225-380 MHz bands in AM mode.Business Most business related entities not covered by other tags.Corrections Jail/prison operations, corrections activities, federal prisons.Emergency Ops Emergency Operation Centers and similar emergency management or disaster related operations.EMS Dispatch Ambulance dispatch, including rescue squads.EMS-Tac Ambulance on-scene communications, tactical operations and secondary channels.EMS-Talk Ambulance talk-around, car-to-car and supervisor operations.Federal All federal government operations (except corrections, traditional law enforcement patrol and re/EMS operations).Fire Dispatch Fire dispatch, including combined re/ambulance dispatch.Fire-Tac Fireground, tactical and on-scene communications, including combined re/ambulance operations.Fire-Talk Fire talk-around and car-to-car operations, chiefs, supervisors, etc., including combined re/ambulance operations.Ham Any amateur radio assignmentHospital Ambulance-to-Hospital communications and patient reports.
81Service Type DescriptionInterop Interoperability communications, cross-agency communications, mutual aid, etc.Law Dispatch Law enforcement dispatch.Law-Tac Law enforcement tactical, SWAT, on-scene, surveillance and specic sub-agency communications.Law Talk Law enforcement talk-around, car-to-car and supervisor operations. Media Newspapers, television and broadcast radio operations.Military Military operations, e.g., range control, air-to-air combat, etc.Multi-Dispatch Combined law enforcement and re/ambulance dispatch.Multi-Tac Combined law enforcement and re/ambulance tactical and on-scene communications.Multi-Talk Combined law enforcement and re/ambulance tactical talk-around and car-to-car operations.Public Works Public agency non-public safety communications. This includes any non-public safety government services, such as trash, streets, roads, sewer, zoos, administration, maintenance, animal control, community initiatives, code compliance, etc.Racing Officials Available for use to identify ofcials’ frequencies for racing events.Racing Teams Available for use to identify team frequencies for racing events.Railroad All common carrier railroad communications.Schools School-related communications (schools, school buses, football games, etc.).Security Non-law enforcement security operations, including private security companies, noncommissioned government agency security, school security, etc.Transportation Public and private bus, taxi, and public passenger rail communications.Utilities Private electric, water, natural gas, phone, cable TV, etc. operations.Other Miscellaneous channels that do not fall into another service type.Custom 1-8 User-dened service types. These can be used for custom groups of channels, systems, sites, etc.REMOVING THE microSD CARDTurn your scanner off. Carefully remove the microSD card by using a thumbnail or pencil eraser to push the card in so it will spring out. Handle with care if you are going to use it in a card reader. Gently install the microSD card the same way it was removed and to push the card in so it will spring back into place.Reformatting the microSD CardReformat microSD cards using a special SD Card Formatter (https://www.sdcard.org/downloads/formatter_4/). Then, you need to “Clear User Data” using Sentinel to restore all HP les and directories to the card.
82After formatting, the HP won’t be automatically detected (since it is wiped clean), so you may need to uncheck “Hide empty drives” in windows “Tools>Folder Options>View before doing the “Clear User Data” step.ENTERING IDSThese are the acceptable ID entry formats.Partial IDs can be used to receive all IDs in a Fleet, Sub-Fleet, Agency, etc.Partial IDs can also be Avoided.System Type TGID FormatMotorola Type 1 SystemsB = BlockF = FleetS = Sub-FleetN = Decimal Numberi = I-Call IDBFF-SS = Normal IDBFFF-S = Normal ID (Fleet is 100 - 127)BFF- = Partial Fleet IDBFFF- = Partial Fleet ID (Fleet is 100 - 127)B- = Partial Block IDSNNNNN (Size code 0)iNNNNN (Size code 0)Motorola Type 2 SystemsN = Decimal NumberH = Hexadecimal Numberi = I-Call IDDecimal FormatNNNNNiNNNNNHexadecimal FormatHHHHiHHHHP25 Systems N = Decimal NumberH = Hexadecimal Numberi = I-Call IDDecimal FormatNNNNNiNNNNNNNNHexadecimal FormatHHHHiHHHHHHEDACS Systems A = AgencyF = FleetS = Sub-FleetN = Decimal Numberi = I-Call IDOnly AFS Format is allowed for direct entry except for I-Call ID.AFS FormatAA-FFS  (Normal ID)AA-FF-  (Partial Fleet ID)AA-  (Partial Agency ID)Decimal FormatNNNNiNNNNNLTR Systems A = Area numberRR = Home Repeater NumberU = Decimal NumberA-RR-UUU  (Normal ID)A-RR  (Partial Repeater ID)Note:  A-RR (Partial Repeater ID) cannot be used with decimal formats.TYPE II SPECIAL STATUS BITSType II Motorola Smartnet systems use these status bits for special transmissions such as emergency, patches, DES/DVP scrambled transmissions, and multiselects. Motorola trunking radios directly interpret them for their special functions, thus no difference is noticed by the person with the radio. The scanner however interprets these special talk group status bits as different talk groups entirely. Below is the conversion chart for these special status bits.
83TT ID + # Usage TT ID + # UsageID+0 Normal Talk group ID+8 DES/DVP Encryption talk groupID+1 All Talk group ID+9 DES All Talk groupID+2 Emergency ID+10 DES EmergencyID+3 Talk group patch to another ID+11 DES Talk group patchID+4 Emergency Patch ID+12 DES Emergency PatchID+5 Emergency multi-group ID+13 DES Emergency multi-groupID+6 unassigned ID+14 unassignedID+7 Multi-select (initiated by dispatcher) ID+15 Multi-select DES TGTherefore, if a user was transmitting a multi-select call on talk group 1808, the scanner would actually receive those transmissions on 1815. Some common uses of these status bits are as follows:When a user hits their emergency button, all conversations on the talk group revert to the emergency status talk group (ID+2) until the dispatch clears the emergency status. Therefore, if someone hit their emergency button and their radio was on talk group 16, all communications would switch to talk group 18.A lot of Fire and EMS departments dispatch tone-outs and alarms as Multi-select communications (ID+7). Therefore, if your re department dispatch talk group is 1616, and they do dispatch tone-outs and alarms as Multi-selects, then those communications will be on talk group 1623.WEATHER CHANNELSChannel Frequency Channel Frequency1162.550 5162.4502162.400 6162.5003162.475 7162.5254162.425ST Event Code Warning Watch  Advisory Denition?ADR Administrative Message O Admin MessageAVA Avalanche Watch O AvalancheAVW Avalanche Warning O AvalancheBHW Biological Hazard Warning O BiologicalBWW Boil Water Warning O Boil WaterBZW Blizzard Warning O BlizzardCAE Child Abduction Emergency O Child EmergencyCDW Civil Danger Warning O Civil DangerCEM Civil Emergency Message O Civil EMGCFA Coastal Flood Watch O Coastal FloodCFW Coastal Flood Warning O Coastal Flood
84ST Event Code Warning Watch  Advisory Denition?CHW Chemical Hazard Warning O ChemicalCWW Contaminated Water Warning O Contam. WaterDBA Dam Watch O Dam BreakDBW Dam Break Warning O Dam BreakDEW Contagious Disease Warning O ContagiousDMO Practice/Demo O System DemoDSW Dust Storm Warning O Dust StormEAN Emergency Action NotificationO EMG NotifyEAT Emergency Action TerminationO EMG TerminateEQW Earthquake Warning O Earthquake EVA Evacuation Watch O Evacuate NoteEVI Immediate Evacuation O Evacuate NoteFCW Food Contamination Warning O FoodFFA Flash Flood Watch O Flash FloodFFS Flash Flood Statement O Flash FloodFFW Flash Flood Warning O Flash FloodFLA Flood Watch O FloodFLS Flood Statement O FloodFLW Flood Warning O FloodFRW Fire Warning O FireFSW Flash Freeze Warning O Flash FreezeFZW Freeze Warning O FreezeHLS Hurricane Statement O HurricaneHMW Hazardous Material Warning O HazardousHUA Hurricane Watch O HurricaneHUW Hurricane Warning O HurricaneHWA High Wind Watch O High WindHWW High Wind Warning O High WindIBW Iceberg Warning O IcebergIFW Industrial Fire Warning O Industrial FireLAE Local Area Emergency O Local EMGLEW Law Enforcement Warning O Law EnforcementLSW Land Slide Warning O Land SlideNAT National Audible Test O National Audible
85ST Event Code Warning Watch  Advisory Denition?NIC National Information Center O National InfoNMN Network Notification MessageO Network MessageNPT National Periodic Test O Nation PeriodNST National Silent Test O Nation SilentNUW Nuclear Power Plant Warning O Nuclear PlantPOS Power Outage Advisory O Power OutageRHW Radiological Hazard Warning O RadiologicalRMT Required Monthly Test O MonthlyRWT Required Weekly Test O WeeklySMW Special Marine Warning O Special MarineSPS Special Weather Statement O Special WXSPW Shelter In-Place Warning O SheleterSVA Severe Thunderstorm Watch O ThunderstormSVR Severe Thunderstorm WarningO ThunderstormSVS Severe Weather Statement O Severe WXTOA Tornado Watch O TornadoTOE 911 Telephone Outage EmergencyO 911 Phone OutageTOR Tornado Warning O TornadoTRA Tropical Storm Watch O Tropical StormTRW Tropical Storm Warning O Tropical StormTSA Tsunami Watch O TsunamiTSW Tsunami Warning O TsunamiTXB Transmitter Backup On O TX Backup OnTXF Transmitter Carrier Off O TX Carrier OffTXO Transmitter Carrier On O TX Carrier OnTXP Transmitter Primary On O TX Primary OnVOW Volcano Warning O VolcanoWFA Wild Fire Watch O Wild FireWFW Wild Fire Warning O Wild FireWSA Winter Storm Watch O Winter StormWSW Winter Storm Warning O Winter Storm**A Unrecognized Watch O Unrecognized**E Unrecognized Emergency O Unrecognized**S Unrecognized Statement O Unrecognized
86ST Event Code Warning Watch  Advisory Denition?**W Unrecognized Warning O UnrecognizedContinuous Tone Coded Squelch System (CTCSS) and Digital Coded Squelch (DCS) are two methods used to prevent interference by other radio communications. Your scanner can receive transmissions that use these codes. CTCSS and DCS systems all use some form of coded squelch. Coded squelch involves the transmission of a special code signal along with the audio of a radio transmission. A receiver with coded squelch only activates when the received signal has the correct code. This lets many users share a single frequency, and decreases interference caused by distant transmitters on the same channel. In all major metropolitan areas of the United States, every available radio channel is assigned to more than one user.CTCSS FREQUENCIESThe scanner can detect the following 50 CTCSS frequencies.67.0Hz 94.8Hz 131.8Hz 171.3Hz 203.5Hz69.3Hz 97.4Hz 136.5Hz 173.8Hz 206.5Hz71.9Hz 100.0Hz 141.3Hz 177.3Hz 210.7Hz74.4Hz 103.5Hz 146.2Hz 179.9Hz 218.1Hz77.0Hz 107.2Hz 151.4Hz 183.5Hz 225.7Hz79.7Hz 110.9Hz 156.7Hz 186.2Hz 229.1Hz82.5Hz 114.8Hz 159.8Hz 189.9Hz 233.6Hz85.4Hz 118.8Hz 162.2Hz 192.8Hz 241.8Hz88.5Hz 123.0Hz 165.5Hz 196.6Hz 250.3Hz91.5Hz 127.3Hz 167.9Hz 199.5Hz 254.1HzDCS CODES The scanner can detect the following hexadecimal DCS codes.006 031 054 116 145 205 245 266 332 411 452 506 612 703007 032 065 122 152 212 246 271 343 412 454 516 624 712015 036 071 125 155 214 251 274 346 413 455 523 627 723017 043 072 131 156 223 252 306 351 423 462 526 631 731021 047 073 132 162 225 255 311 356 431 464 532 632 732023 050 074 134 165 226 261 315 364 432 465 546 654 734025 051 114 141 172 243 263 325 365 445 466 565 662 743026 053 115 143 174 244 265 331 371 446 503 606 664 754
87REVERSE LISTBase Frequency(MHz)Offset(MHz)Base Frequency(MHz)Offset(MHz)29.5200 - 29.5800 +0.1 450.0000 - 454.9875 +529.6200 - 29.6800 -0.1 455.0000 - 459.9875 -552.0100 - 52.9900 +1 460.0000 - 464.9875 +553.0100 - 53.9900 -1 465.0000 - 469.9875 -5143.7500 +4.375 470.0000 - 472.9875 +3143.9000 +4.25 473.0000 - 475.9875 -3144.5100 - 144.8900 +0.6 476.0000 - 478.9875 +3145.1100 - 145.4900 -0.6 479.0000 - 481.9875 -3146.0100 - 146.3850 +0.6 482.0000 - 484.9875 +3146.4150 - 146.5050 +1 485.0000 - 487.9875 -3146.5950 +1 488.0000 - 490.9875 +3146.6100 - 146.9850 -0.6 491.0000 - 493.9875 -3147.0000 - 147.3900 +0.6 494.0000 - 496.9875 +3147.4150 - 147.5050 -1 497.0000 - 499.9875 -3147.5950 -1 500.0000 - 502.9875 +3147.6000 - 147.9900 -0.6 503.0000 - 505.9875 -3148.1250 -4.375 506.0000 - 508.9875 +3158.1500 -4.25 509.0000 - 511.9875 -3222.1200 - 223.3800 +1.6 758.0000 - 775.9937 +30223.7200 - 224.9800 -1.6 788.0000 - 805.9937 -30420.0000 - 424.9875 +5 806.0000 - 823.9875 +45425.0000 - 429.9875 -5 851.000 - 868.9875 -45440.0000 - 444.9875 +5 896.0000 - 901.0000 +39445.0000 - 449.9875 -5 935.0000 - 940.0000 -39REPEATER FREQUENCY LISTBase Frequency(MHz)Offset(MHz)Base Frequency(MHz)Offset(MHz)455.0151 - 459.9950 -5 497.0001 - 500.0000 -3465.0101 - 469.9950 -5 503.0001 - 506.0000 -3473.0001 - 476.0000 -3 509.0001 - 512.0000 -3479.0001 - 482.0000 -3 758.0000 - 775.9937 +30485.0001 - 488.0000 -3 806.0051 - 823.9875 +45491.0001 - 494.0000 -3 894.0125 - 921.0000 +39
88TECHNICAL SPECIFICATIONS  BCD436HPBand Coverage  :  31 BandsSize:   2.8 in (W) x 1.5 in (D) x 6.3 in (H) (without antenna)  71.1 mm (W) x 36.9 mm (D) x 160.9 mm (H) (without antenna) Weight: 12.3 oz. (with antenna and battery)Operating Temperature:   + 14º F (– 10º C) to  + 140º F (+ 60º C ) Storage Temperature:   –  22º F (– 30º C) to  + 158º F (+ 70º C ) Power Requirements:   3 X AA Rechargeable Ni-MH Batteries (2300mAh)  (included)   3 X AA Alkaline Batteries (not included)   DC 5.0V ±5%. Connect to PC with USB cable (included)LCD Display:  192 X 160 Full Dot Matrix LCD with white-color backlight.Internal Speaker:  24ohm, 0.8W Max.Certied in accordance with FCC Rules and Regulations Part 15 Sub-part C as of date of manufacture. Weather Channels:  7 ChannelsScan Rate:  85 channels/second Search Rate:  80 steps/second (12.5kHz step) 250 steps/second (5kHz step)Scan Delay:  2 secondsAudio Output Power:  Internal Speaker - 360mW nominal     (24ohm)     Headphone (L-ch) 4mW nominal     (32 ohm)Antenna:  50 ohms (Impedance)Sensitivity (12dB SINAD) NominalVHF Low 1 Band(AM) 25.005 MHz 0.4 μV(NFM) 40.840 MHz 0.3 μV(NFM) 53.980 MHz 0.3 μVVHF Low 2 Band(WFM) 54.050 MHz 0.7 μV(FM) 72.515 MHz 0.3 μV(FMB) 107.100 MHz 0.6 μVAircraft Band(AM) 118.800 MHz 0.4 μV(AM) 127.175 MHz 0.4 μV(AM) 135.500 MHz 0.4 μV
89VHF High 1 Band(NFM) 138.150 MHz 0.4 μV(NFM) 161.985 MHz 0.3 μV(NFM) 173.225 MHz 0.3 μV(WFM) 197.450 MHz 0.6 uV(NFM) 216.020 MHz 0.3 uVVHF High 2 Band(AM) 225.050 MHz 0.3 μV(AM) 272.950 MHz 0.4 μV(AM) 315.050 MHz 0.4 μVUHF Band(AM) 325.050 MHz 0.4 μV(NFM) 406.875 MHz 0.3 μV(NFM) 511.9125 MHz 0.3 μVPublic Service Band(NFM) 758.0125 MHz 0.3 μV(NFM) 806.000   MHz 0.3 μV(NFM) 857.150   MHz 0.3 μV(NFM) 954.9125 MHz 0.3 μV1200MHz Band(NFM) 1299.925 MHz 0.4 μVClose Call Sensitivity (No Modulation)(NFM) 40.8400 MHz -58 dBm(FM) 72.5150 MHz -65 dBm(AM) 127.1750 MHz -69 dBm(NFM) 161.9850 MHz -71 dBm(AM) 272.9500 MHz -71 dBm(NFM) 406.8750 MHz -66 dBm(NFM) 857.1500 MHz -64 dBm(NFM) 1299.9250 MHz -58 dBmSignal Noise Ratio (nominal)VHF Low 1 Band(AM) 25.0050 MHz 49 dB(NFM) 40.8400 MHz 43 dBVHF Low 2 Band(WFM) 54.0500 MHz 53 dB
90(FM) 72.5150 MHz 47 dB(FMB) 107.100 MHz 60 dBAircraft Band(AM) 127.1750 MHz 50 dBVHF High 1 Band(NFM) 161.9850 MHz 41 dB(NFM) 173.2250 MHz 42 dB(WFM) 197.4500 MHz 52 dBVHF High 2 Band(AM) 272.9500MHz 50 dBUHF Band(AM) 325.0500 MHz 50 dB(NFM) 406.8750 MHz 41 dBPublic Service Band(NFM) 758.0125 MHz 42 dB(NFM) 857.1500 MHz 42 dB1200 MHz Band(NFM) 1299.9250 MHz 41 dBFeatures, specications, and availability of optional accessories are all subject to change without notice. TECHNICAL SPECIFICATIONS  BCD536HPSize: 7.2 in W (184 mm) x 5.9 in D (151) x 2.2 in H (56 mm) Weight: 54.3 oz. (without accessories)Operating Temperature:   + 14º F (– 10º C) to  + 140º F (+ 60º C )  Storage Temperature:   –  22º F (– 30º C) to  + 158º F (+ 70º C ) Power Requirements:   DC 11.0 V - 16.6 V (Ext. DC Power Jack or DC Power Jack) Orange Wire Operation:  DC 3 V - 16.6 V (Less than 10mA)LCD Display:  64 X 288 Full Dot Matrix LCDInternal Speaker:  8 ohm, 5W Max.Certied in accordance with FCC Rules and Regulations Part 15 Sub-part C as of date of manufacture. Weather Channels:    7 ChannelsScan Rate:     85 channels/second (nominal)Search Rate:     80 steps/second (nominal)    250 steps/second (5kHz step - nominal)
91Scan Delay:     2 secondsAudio Output Power :  5W Max., 8 ohm LoadAntenna:     50 ohms (Impedance)Sensitivity (12dB SINAD) NominalVHF Low Band(AM) 25.005 MHz 0.4 μV(NFM) 40.840 MHz 0.2 μV(NFM) 53.980 MHz 0.2 μVVHF Low 2 Band(WFM) 54.050 MHz 0.6 μV(FM) 72.515 MHz 0.2 μV(FMB) 107.100 MHz 0.6 μVAircraft Band(AM) 118.800 MHz 0.3 μV(AM) 127.175 MHz 0.3 μV(AM) 135.500 MHz 0.3 μVVHF High 1 Band(NFM) 138.150 MHz 0.2 μV(NFM) 161.985 MHz 0.2 μV(NFM) 173.225 MHz 0.3 uV(WFM) 197.450 MHz 0.6 uV(NFM) 216.020 MHz 0.3 uVVHF High 2 Band(AM) 225.050 MHz 0.3 μV(AM) 272.950 MHz 0.3 μV(AM) 315.050 MHz 0.4 μVUHF Band(AM) 325.050 MHz 0.4 μV(NFM) 406.8750 MHz 0.3 μV(NFM) 511.9125 MHz 0.3 μVPublic Service Band(NFM) 758.0125 MHz 0.3 μV(NFM) 806.000   MHz 0.3 μV(NFM) 857.150   MHz 0.2 μV(NFM) 954.9125 MHz 0.2 μV1200MHz Band(NFM) 1299.9250MHz 0.3 μV
92Close Call Sensitivity (No Modulation)(NFM) 40.8400 MHz -60dBm(FM) 72.5150 MHz -62dBm(AM) 127.1750 MHz -67dBm(NFM) 161.9850 MHz -66dBm(AM) 272.9500 MHz -67dBm(NFM) 406.8750 MHz -63dBm(NFM) 857.1500 MHz -63dBm(NFM) 1299.9250 MHz -56dBmSignal Noise Ratio (nominal)VHF Low 1 Band(AM) 25.0050 MHz 48dB(NFM) 40.8400 MHz 42dBVHF Low 2 Band(WFM) 54.0500 MHz 52dB(FM) 72.5150 MHz 47dB(FMB) 107.1000 MHz 58dBAircraft Band(AM) 127.1750 MHz 49dBVHF High 1 Band(NFM) 161.9850 MHz 40dB(NFM) 173.2250 MHz 41dB(WFM) 197.4500 MHz 53dBVHF High 2 Band(AM) 272.9500 MHz 49dBUHF Band(AM) 325.0500 MHz 49dB(NFM) 406.8750 MHz 40dBPublic Service Band(NFM) 758.0125 MHz 41dB(NFM) 857.1500 MHz 41dB1200 MHz Band(NFM) 1299.9250 MHz 42dBFeatures, specications, and availability of optional accessories are all subject to change without notice.
93WARRANTY INFORMATIONWARRANTOR: UNIDEN AMERICA CORPORATION (Uniden) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WARRANTY DURATION: This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. The warranty is invalid if the Product is(A) damaged or not maintained as reasonable or necessary, (B) modied, altered, or used as part of any conversion kits, subassemblies, or any congurations not sold by Uniden, (C) improperly installed, (D) serviced or repaired by someone other than an authorized Uniden service center for a defect or malfunction covered by this warranty, (E) used in any conjunction with equipment or parts or as part of any system not manufactured by Uniden, or (F) installed or programmed by anyone other than as detailed by the Operating Guide for this product. STATEMENT OF REMEDY: In the event that the product does not conform to this warranty at any time while this warranty is in effect, warrantor will repair the defect and return it to you without charge for parts, service, or any other cost (except shipping and handling) incurred by warrantor or its representatives in connection with the performance of this warranty. THE LIMITED WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or exclusion might not apply to you. LEGAL REMEDIES: This warranty gives you specic legal rights, and you might also have other rights which vary from state to state. This warranty is void outside the United States of America. PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: If, after following the instructions in this Operating Guide you are certain that the Product is defective, pack the Product carefully (preferably in its original packaging). Include evidence of original purchase and a note describing the defect that has caused you to return it. The Product should be shipped freight prepaid, by traceable means, or delivered, to warrantor at: Uniden America Corporation Parts and Service Division 743 Henrietta Creek Rd. Roanoke, Texas 76262.