Triton Network Systems 28-SNP-03 User Manual Installation Manual

Triton Network Systems, Inc. Installation Manual

Contents

Installation Manual

,QYLVLEOH)LEHU708QLW,QVWDOODWLRQ*XLGHIRU*+]621(72&-$SSOLFDWLRQV
© 1999 Triton Network Systems, Inc. All Rights Reserved.This document and the information contained therein is the proprietary and confidential information of Triton Network Systems, Inc. that is provided by Triton Network Systems exclusively for evaluating the purchase of Triton Network Systems, Inc. technology and is protected by copyright and trade secret laws. No part of this document may be disclosed, reproduced, or transmitted in any form or by any means, electronic or mechanical, for any purpose without express written permission of Triton Network Systems, Inc., 8529 SouthPark Circle, Orlando, FL 32819.For permissions, contact marketing at +1-407-903-0975 or +1-407-903-0997 (FAX).Notice of DisclaimerThe information and specifications provided in this document are subject to change without notice.The Warranty(s) that accompany Triton Network Systems, Inc., products are set forth in the sales agreement/contract between Triton Network Systems, Inc., and its customer. Please consult the sales agreement for the terms and conditions of the Warranty(s) provided by Triton Network Systems, Inc. To obtain a copy of the Warranty(s), contact Triton Network Systems, Inc., the Marketing Group at +1-407-903-0975 or +1-407-903-0997 (FAX).The information provided in this Triton Network Systems, Inc., document is provided “as is” without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Some jurisdictions do not allow the exclusion of implied warranties, so the above exclusion may not apply to you.In no event shall any Triton Network Systems, Inc., company be liable for any damages whatsoever—including special, indirect, consequential or incidental damages or damages for loss of profits, revenue, use, or data whether brought in contract or tort, arising out of or connected with any Triton Network Systems, Inc., Document or the use, reliance upon or performance of any material contained in or accessed from this Triton Network Systems, Inc. document. Triton Network Systems’ license agreement may be provided upon request. Additional Terms and Conditions will be finalized upon negotiation of a purchase.Trademark InformationInvisible Fiber™ is a trademark of Triton Network Systems, Inc. All other brand or product names are trademarks or registered trademarks of their respective companies or organizations.Part Number: 5036001-0002
28 GHz SONET OC-3 IFU Installation - R1.0 iiiContentsList of Figures ................................................................................... viiList of Tables ..................................................................................... ixAbout This Book  ............................................................................... xiPurpose of This Book  ....................................................................................xiIntended Audience .........................................................................................xiFormat of This Book .....................................................................................xiiConventions Used in This Book ...................................................................xiiContacting Triton Network Systems, Inc.  ...................................................xiiiWarnings and Safety Guidelines  .....................................................xvConventions .................................................................................................. xvRisk of Personal Injury from Electrical Shock ............................................xviRisk of Personal Injury from Fiber Optics ...................................................xviRisk of Personal Injury from Radio Frequency Energy Exposure  ..............xviOther Risks of Personal Injury ....................................................................xviiRisk of Service Interruption .......................................................................xviiiOther Precautions .........................................................................................xixAvertissements et consignes de sécurité ........................................ xxiConventions .................................................................................................xxiRisque de lésions corporelles provoquées par la décharge électrique ........xxiiRisque de lésions corporelles provoquées par les câbles à fibres optiques  xxii
iv © 1999 Triton Network Systems, Inc. All Rights Reserved.Risque de lésions corporelles provoquées par l’exposition de l’énergie radiofréquences ..........................................................................................xxiiiAutres risques des lésions corporelles  .......................................................xxiiiRisque d’interruption de service ................................................................xxivAutres mises en garde .................................................................................xxvChapter 1 — Installation Overview  .............................................. 1-1Installation Overview ...................................................................................1-1Site Engineering Folder .........................................................................1-1IFU Link Manager .................................................................................1-2Power Source  ...............................................................................................1-2Cabling .........................................................................................................1-2Power Cable  ..........................................................................................1-2Fiber Optic Cable  ..................................................................................1-2System Grounding and Surge Protection .....................................................1-3Earth Ground .........................................................................................1-3Surge Protection  ....................................................................................1-3Chapter 2 — Staging Procedure .................................................... 2-1Configuring IFUs .........................................................................................2-1Chapter 3 — Installation Procedures  ........................................... 3-1Setup ............................................................................................................3-2Before Starting  ......................................................................................3-2Preparing for Installation .......................................................................3-2Installing IFU Components ..........................................................................3-3Mounting the IFU Bracket  ....................................................................3-3Installing Power Cables .........................................................................3-5IFU Power Cable Test ...........................................................................3-7Installing the Fiber Optic Cable  ............................................................3-9Fiber Optic Continuity Test .................................................................3-14Installing an IFU  ........................................................................................3-18Mounting the IFU ................................................................................3-18Attaching IFU Cables ..........................................................................3-21
28 GHz SONET OC-3 IFU Installation - R1.0 vChapter 4 — Commissioning Procedures  .................................... 4-1Setup ............................................................................................................4-2Before Starting  ......................................................................................4-2Preparing for Installation .......................................................................4-2Aligning the IFU ..........................................................................................4-3Commissioning the IFU ...............................................................................4-6SONET OC-3 Link Performance Test .........................................................4-8Chapter 5 — Removing an IFU ..................................................... 5-1Servicing an IFU ..........................................................................................5-2Removing an IFU .........................................................................................5-2Removing Cables  ..................................................................................5-2Removing an IFU from a Mounting Bracket  ........................................5-4Packing the IFU for Shipment  .....................................................................5-5Appendix A — IFU Test Results  .................................................. A-1Power Source Tests .....................................................................................A-1SONET OC-3 Fiber Optic Test  ..................................................................A-2Far-End Test  ...............................................................................................A-2Near-End Test .............................................................................................A-2SONET OC-3 Link Performance Test ........................................................A-3Invisible Fiber™ Product Glossary ................................... glossary-1Index ..........................................................................................index-1
vi © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 viiList of FiguresFigure 1-1. SONET OC-3  Fiber Optic Cable Configuration  ................1-4Figure 2-1. IFU Lifting Guideline ..........................................................2-3Figure 2-2. IFU Power Cable Hookup  ...................................................2-4Figure 2-3. Power Test Setup  .................................................................2-4Figure 2-4. IFU Configuration Setup  .....................................................2-6Figure 3-1. Example of IFU Bracket Attached to Wall ..........................3-3Figure 3-2. Example of IFU Bracket Attached to Pole ..........................3-4Figure 3-3. Typical Power Cable Wiring  ...............................................3-6Figure 3-4. Typical IFU Power Termination Wiring Schematic  ............3-7Figure 3-5. Power Test Setup  .................................................................3-8Figure 3-6. Demarcation Patch Panel ...................................................3-11Figure 3-7. Typical SONET OC-3 Site Schematic ...............................3-13Figure 3-8. Typical SONET OC-3 Demarcation Jumper Locations  ....3-14Figure 3-9. SONET OC-3 Fiber Optic Continuity Test Setup  .............3-17Figure 3-10. Mounting the IFU ..............................................................3-19Figure 3-11. IFU Cable Connections  .....................................................3-21Figure 4-1. Coarse Alignment ................................................................4-3Figure 4-2. Alignment Test Setup  ..........................................................4-4Figure 4-3. SONET Link Test Setup ......................................................4-9Figure 5-1. IFU Cable Connections  .......................................................5-3Figure 5-2. IFU Removal  .......................................................................5-5
viii © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 ixList of TablesTable 2-1. Typical IFU Configuration Parts List  ..................................2-1Table 3-1. Site Installation Tools ..........................................................3-2Table 3-2. Site Installation Parts (for two IFUs) ...................................3-2Table 3-3. Typical Power Cable Wiring  ...............................................3-6Table 3-4. Typical SONET OC-3 Demarcation Panel Input Connections 3-12Table 3-5. Typical SONET OC-3 Demarcation Panel Jumper Connections 3-14Table 3-6. SONET OC-3 Fiber Test Connections  ..............................3-18Table 4-1. Site Commissioning Tools ...................................................4-2Table A-1. Power Supply Test Results  .................................................A-1Table A-2. SONET OC-3 Fiber Optic Test Results ..............................A-2Table A-3. Far-End Test Results #1 ......................................................A-2Table A-4. Far-End Test Results #2 ......................................................A-2Table A-5. Near-End Test Results #1  ...................................................A-2Table A-6. Near-End Test Results #2  ...................................................A-3Table A-7. SONET OC-3 Link Performance Test ................................A-3
x© 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 xiAbout This BookThe Triton Network Systems, Inc., 28 GHz Invisible Fiber™ unit (IFU) delivers high bandwidth, high-speed traffic through a wireless transport. IFUs are configured at the factory to work with Fast Ethernet or SONET applications. This book describes the SONET OC-3 application for the IFU.Purpose of This BookThis book describes how to:Configure IFUsPerform preparatory (prior to installation) operations on an IFU, such as downloading attributes.Install IFUsInstall the brackets, mount the IFU, and run and connect cables.Commission IFUsAlign IFUs and perform a series of tests to ensure proper operation.Remove IFUsServicing and removing and IFU.The procedures include required verification tests and appropriate warning messages.Intended AudienceThis book is written specifically for installation and commissioning technicians and network engineers. The book assumes that the reader has a basic understanding of installing hardware.
xii © 1999 Triton Network Systems, Inc. All Rights Reserved.Format of This BookThis book contains:Conventions Used in This BookThis book uses the following conventions:nItalic - to indicate:½A book title½A heading or chapter title reference (for example, See Conventions Used in This Book)½Word emphasis (for example, Do not turn on the power ....)nA Note: label to identify an informational note. For example:NOTE:  Refer to the previous chapter for more information.For warning and safety precaution conventions, see Conventions on page xv (English version) or Conventions on page xxi (French version).Book Unit DescriptionWarnings and Safety Guidelines on page xv Provides a list of all warning, danger, and caution messages related to working with IFUs.Chapter 1, Installation Overview Describes a typical IFU installation, the types of cables used, and power requirements.Chapter 2, Staging Procedure Provides the procedures to perform before installing the IFU.Chapter 3, Installation Procedures Provides the component installation procedures.Chapter 4, Commissioning Procedures Provides alignment and test procedures to ensure proper operation.Chapter 5, Removing an IFU Provides the procedure to remove and replace an IFU.Appendix A, IFU Test Results Provides test forms.Invisible Fiber™ Product Glossary Provides descriptions of product terminology.Index Provides an alphabetical list with the page location of information included in this book.
28 GHz SONET OC-3 IFU Installation - R1.0 xiiiContacting Triton Network Systems, Inc.Direct any questions to your project liaison or:Triton Network Systems, Inc.Technical Assistance Center (TAC)8529 SouthPark CircleOrlando, FL 32819Telephone - Domestic, Toll-free: 1-877-6TRITON (1-877-687-4866) Telephone - International: +1-407-903-2070E-Mail: support@triton-network.comFAX: +1-407-903-0995
xiv © 1999 Triton Network Systems, Inc. All Rights Reserved.
Warnings and Safety Guidelines (9/17/99) - R0.1 xvCONFIDENTIAL & PROPRIETARYDO NOT COPYWarnings and Safety GuidelinesConventionsThe following list identifies the warning and caution graphic symbols used in this guide:Risk of Personal Injury from Electrical ShockThis symbol indicates a risk of personal injury due to an electrical shock.Risk of Personal Injury from Fiber OpticsThis symbol indicates a risk of personal injury from fiber optic cable laser radiation.Risk of Personal Injury from Radio Frequency Energy ExposureThis symbol indicates a risk of personal injury due to radio frequency energy exposure.Other Risks of Personal InjuryThis symbol indicates a risk of personal injury from a source other than electrical shock, laser radiation, or radio frequency energy exposure.Risk of Service InterruptionThis symbol indicates a risk of service interruption or equipment damage.
xvi © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYRisk of Personal Injury from Electrical Shock DANGER – HIGH CURRENT HAZARD: Do not turn on power before reading the Triton Network Systems’ product documentation. This device has a – 48 Vdc (4 amps operating peak per feed) direct current input.DANGER – HIGH CURRENT HAZARD: Ensure that the – 48 Vdc power source is set to the OFF position before beginning the installation procedures for the Invisible Fiber™ unit. DANGER – HIGH VOLTAGE HAZARD: Do not work on the system or connect or disconnect cables during periods of lightning activity, rainy weather, or both.WARNING: Instructions for installing cables are intended for licensed contractors or building maintenance personnel.Risk of Personal Injury from Fiber Optics DANGER: Invisible laser radiation. Avoid direct eye exposure to the end of a fiber, fiber cord, or fiber pigtail. The infrared light used in fiber optics systems is invisible, but can cause serious injury to the eye.WARNING: Never touch exposed fiber with any part of your body. Fiber fragments can enter the skin and are difficult to detect and remove.Risk of Personal Injury from Radio Frequency Energy ExposureWARNING: Beware! Radio transmitter is ON when the red light indicator on back side of Invisible Fiber™ unit is illuminated. Observe all radio frequency energy exposure and service interruption cautions.WARNING – RF EXPOSURE HAZARD: Ensure the safety of all personnel. Do not stand in front of the Invisible Fiber™ unit (antenna) in order to avoid possible harmful radio frequency energy exposure.
Other Risks of Personal InjuryWarnings and Safety Guidelines (9/17/99) - R0.1 xviiCONFIDENTIAL & PROPRIETARYDO NOT COPYOther Risks of Personal InjuryNOTE:  The following warning and cautions are for risk of injury from sources other than electrical shock, fiber optics, or radio frequency energy exposure.WARNING: This Invisible Fiber™ unit is designed to permit the connection of the earthed conductor from the DC source circuit to the earthing conductor at the Invisible Fiber™ unit. Do not switch or disconnect devices in the earthed circuit conductor between the DC source and point of connection of the earthing electrode conductor.WARNING: Failure to follow operating instructions could result in death or serious injury.CAUTION: Instructions for installing cables are intended for licensed contractors or building maintenance personnel.CAUTION: Lifting hazard: Two people are required to lift the Invisible Fiber™ unit. Grasp the Invisible Fiber™ unit underneath the lower edge and lift with both hands. To prevent injury, keep your back straight and lift with your legs, not your back. To prevent damage to the Invisible Fiber™ unit and components, never attempt to lift the radio by the attached cables.CAUTION: Keep tools and parts away from walkways. When carrying large, heavy equipment (such as the Invisible Fiber™ unit), obstacles (such as hand tools, cables or components) may not be easily visible and can cause accidents.
xviii © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYRisk of Service InterruptionCAUTION: Handle the Invisible Fiber™ unit with care to avoid equipment damage.CAUTION: Ensure the outside optical fiber connectors are environmentally protected. Failure to do so may cause contamination of the fiber surfaces.CAUTION: The Invisible Fiber™ unit contains no owner or user serviceable parts. Opening the radio unit or tampering with any of its seals voids all warranties.CAUTION: Prior to installing an Invisible Fiber™ unit, the installation site must be surveyed to assess its appropriateness or adequacy, system requirements, path analysis, signal path, and power requirements.CAUTION: Instructions for installing cables are intended for licensed contractors or building maintenance personnel.CAUTION: DO NOT lift the Invisible Fiber™ unit by the Radome (front) Cover to avoid damaging the antenna.CAUTION: Ensure the mounting bracket and Invisible Fiber™ unit are installed properly according to the instructions in the Triton Network Systems’ product documentation.CAUTION: Ensure that the – 48 Vdc power source is set to the OFF position before attaching power cables to the Invisible Fiber™ unit.CAUTION: Do not block the front of the Invisible Fiber™ unit to avoid possible radio service interruption.CAUTION: To reduce the risk of fiber optic cable damage, use the following bend radius guidelines for indoor/outdoor fiber optic cable: nLong-term (installed): bend radius is equal to 10 times the diameter of the cable.nShort-term (during installation): bend radius is equal to 20 times the diameter of the cable.
Other PrecautionsWarnings and Safety Guidelines (9/17/99) - R0.1 xixCONFIDENTIAL & PROPRIETARYDO NOT COPYOther PrecautionsFailure to follow the installation procedure described in the Triton Network Systems’ product documentation may result in damage to the Invisible Fiber™ unit and render the unit unusable. If you have any questions, contact your Triton Network Systems’ project liaison or the Technical Assistance Center at:Triton Network Systems, Inc.8529 SouthPark CircleOrlando, FL 32819Telephone - Domestic, Toll-free: 1-877-6TRITON (1-877-687-4866)Telephone - International: +1-407-903-2070E-Mail: support@triton-network.comFAX: +1-407-903-0995The Invisible Fiber™ unit must be installed in accordance with wall-mount or pole-mount specifications described in the Triton Network Systems’ product documentation.Observe all federal and local laws, regulations, electrical codes, building codes, fire codes, and licensing agreements.Ensure the safety of all personnel and bystanders from potential radio frequency energy exposure hazards. Observe FCC 47 CFR 1.1307 for environmental assessments, FCC 47 CFR 1.1310 for radio frequency exposure limits, Health Canada Safety Code 6 for limits to exposure to RF fields, and other relevant regulatory and safety compliance rules for proper safety procedures, training, and assessment.Ensure that appropriate warning signs are properly placed and posted at the equipment site or access entry.Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.The equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by performing
xx © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYone or more of the following measures on the radio or television antenna that is affected by interference:nReorient or relocate the receiving antenna.nIncrease the separation between the equipment and the receiver.nConnect the equipment to an outlet on a different circuit than the circuit the receiver is connected to.nConsult the dealer or an experienced radio or TV technician for help.This device complies with RSS-191 of Industry Canada. Operation is subject to the following two conditions:nThis device may not cause interferencenThis device must accept any interference, including interference that may cause undesired operation of the device.This Class B digital apparatus complies with Canadian ICES-003.
Warnings and Safety Guidelines (9/17/99) - R0.1 xxiCONFIDENTIAL & PROPRIETARYDO NOT COPYAvertissements et consignes de sécuritéConventionsLa liste suivante explique les symboles d’avertissement et de mise en garde utilisés dans ce guide:Risque de lésions corporelles provoquées par la décharge électrique Ce symbole indique un risque de lésions corporelles provoquées par la décharge électrique.Risque de lésions corporelles provoquées par les câbles à fibres optiquesCe symbole indique un risque de lésions corporelles provoquées par les câbles à fibres optiques.Risque de lésions corporelles provoquées par l’exposition de l’énergie radiofréquencesCe symbole indique un risque de lésions corporelles provoquées par l’exposition de l’énergie radiofréquences.Autres risques de lésions corporellesCe symbole indique d’un risque de lésions corporelles (à part celles provoquées par la décharge électrique, par la radiation du laser, ou par l’exposition de l’énergie radiofréquences).Risque d’interruption de serviceCe symbole indique un risque d’interruption de service ou de dommage aux équipements.
xxii © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYRisque de lésions corporelles provoquées par la décharge électriqueDANGER – L’HASARD DU COURANT ÉLEVÉ : Ne pas mettre la tension avant de lire la documentation du produit fournie par la société Triton Network Systems. Cet appareil a une alimentation directe de – 48 V CC (courant de pointe de 4 ampères par ligne d’alimentation).DANGER – L’HASARD DU COURANT ÉLEVÉ : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’aborder les procédures pour l’installation de l’unité Invisible FiberMD.DANGER – L’HASARD DU TENSION ÉLEVÉ : Ne pas travailler sur le système ni brancher ni débrancher les câbles durant l’activité de la foudre, par de temps pluvieux, ou tous le deux.AVERTISSEMENT : Les instructions pour l’installation des câbles sont destinées exclusivement aux entrepreneurs agréés et aux préposés à l’entretien de l’immeuble.Risque de lésions corporelles provoquées par les câbles à fibres optiquesDANGER : Rayonnement laser invisible. Éviter l’exposition directe des yeux à l’extrémité d’une fibre, d’un cordon à fibres ou d’une fibre amorce. La lumière infrarouge utilisée dans les systèmes à fibres optiques est invisible, mais peut provoquer des lésions graves aux yeux.AVERTISSEMENT : Ne jamais laisser une fibre nue entrer en contact avec une partie quelconque du corps. Des fragments de fibre peuvent entrer dans la peau, et sont difficiles à déceler et à enlever.
Risque de lésions corporelles provoquées par l’exposition de l’énergie radiofréquencesWarnings and Safety Guidelines (9/17/99) - R0.1 xxiiiCONFIDENTIAL & PROPRIETARYDO NOT COPYRisque de lésions corporelles provoquées par l’exposition de l’énergie radiofréquencesMISE EN GARDE : Attention ! Le poste émetteur est EN MARCHE lorsque le témoin rouge sur le dos de l’unité Invisible FiberMD est allumé. Respecter toutes les mises en garde concernant l’exposition aux radiofréquences et l’interruption de service.MISE EN GARDE – RF EXPOSURE HAZARD : Assurer la sécurité de tout le personnel. Ne pas rester debout devant l’unité Invisible FiberMD (l’antenne) afin d’éviter toute exposition dangereuse aux radiofréquences. Les lésions corporelles serieux s’ensuivre.Autres risques des lésions corporellesLes mises en garde suivantes concernent les risques de lésions corporelles attribuables à des causes autres que la décharge électrique, la radiation du laser, ou l’exposition de l’énergie radiofréquences).AVERTISSEMENT : Cette unité Invisible FiberMD permet la connexion entre le conducteur de mise à la terre du circuit d’alimentation CC et le conducteur de mise à la terre de l’unité Invisible FiberMD. Ne pas changer ni débrancher les dispositifs qui se trouvent dans le conducteur du circuit mis à la terre entre la source de l’énergie CC et le point de connexion au conducteur de l’électrode de prise de terre.AVERTISSEMENT : Ne pas suivre les instructions d’utilisation peut causer de sérieuses blessures et même la mort.MISE EN GARDE : Les instructions pour l’installation des câbles sont destinées exclusivement aux entrepreneurs agréés et aux préposés à l’entretien de l’immeuble.MISE EN GARDE : Danger de levage. Il faut deux personnes pour soulever l’unité Invisible FiberMD. Saisir l’unité Invisible FiberMD au-dessous du rebord inférieur, puis soulever l’unité avec les deux mains. Pour éviter les lésions corporelles, garder le dos en position verticale et soulever l’unité en utilisant les jambes et non pas les reins. Pour éviter l’endommagement de l’unité Invisible FiberMD et de ses composants, ne jamais essayer de soulever la radio en tirant sur les câbles qui y sont attachés.
xxiv © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYMISE EN GARDE : Garder les outils et les pièces loin des allées. Lorsqu’on transporte des équipements lourds et à grandes dimensions (tels que l’unité Invisible FiberMD), les obstacles (tels que les outils à main, les câbles ou les composants) sont parfois difficiles à voir et peuvent causer des accidents.Risque d’interruption de serviceMISE EN GARDE : Manipuler l’unité Invisible FiberMD  avec soin pour éviter des dommages aux équipements.MISE EN GARDE : S’assurer que les raccords extérieurs fibre optique sont protégés contre l’environnement. L’absence d’une telle protection peut entraîner la contamination des surfaces des fibres.MISE EN GARDE : L’unité Invisible FiberMD contient pas de parts utilés par le propriétaire ou l’usager. Ouverture de l’unité de la radio ou toucher aux scelles rend toute garantie nulle et non avenue.MISE EN GARDE : Avant d’installer une unité Invisible FiberMD, il faut vérifier que les lieux de l’installation sont convenables et adéquats, déterminer les besoins du système, analyser les trajets, préciser le parcours du signal et déterminer les exigences en matière d’énergie.MISE EN GARDE : Les instructions pour l’installation des câbles sont destinées exclusivement aux entrepreneurs agréés et aux préposés à l’entretien de l’immeuble.MISE EN GARDE : NE PAS soulever l’unité Invisible FiberMD par le couvercle du radôme (couvercle avant), afin d’éviter l’endommagement de l’antenne.MISE EN GARDE : S’assurer que le support de montage et l’unité Invisible FiberMD  sont installés convenablement, selon les instructions figurant dans la documentation du produit fournie par la société Triton Network Systems.MISE EN GARDE : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’attacher les câbles d’alimentation à l’unité Invisible FiberMD.MISE EN GARDE : Ne pas bloquer le devant de l’unité Invisible FiberMD, pour éviter toute interruption éventuelle du service de transmission radio.
Autres mises en gardeWarnings and Safety Guidelines (9/17/99) - R0.1 xxvCONFIDENTIAL & PROPRIETARYDO NOT COPYMISE EN GARDE : Pour réduire le risque de dommage aux câbles à fibres optiques, suivre les consignes suivantes en matière de rayon de courbure des câbles à fibres optiques extérieurs ou intérieurs : nCorbure à long terme (installée). Le rayon de courbure ne doit pas dépasser 10 fois le diamètre du câble.nCourbure à court terme (pendant l’installation). Le rayon de courbure ne doit pas dépasser 20 fois le diamètre du câble.Autres mises en gardeL’inobservation de la procédure d’installation décrite dans la documentation du produit fournie par la société Triton Network Systems peut endommager l’unité Invisible FiberMD et la rendre inutilisable. Si vous avez des questions à poser, veuillez communiquer avec votre agent de liaison des projets chez Triton Network Systems, ou bien joindre notre Centre d’assistance technique à l’adresse suivante :Triton Network Systems, Inc.8529 SouthPark CircleOrlando, FL 32819Téléphone - Aux États-Unis, sans frais : 1-877-6TRITON (1-877-687-4866) Téléphone - Dans d’autres pays : +1-407-903-2070Internet : support@triton-network.comTélécopieur : +1-407-903-0995Il faut installer l’unité Invisible FiberMD selon la spécification pour le montage mural ou sur poteau, telle que précisée dans la documentation du produit fournie par la société Triton Network Systems.Il faut respecter l’ensemble des lois, règlements, codes d’électrique, codes du bâtiment et codes des incendies du gouvernement fédéral et des municipalités ainsi que tous les contrats de licence.Assurez la sécurite de toute les personnels et les autres autour, contre l’hasard d'exposition de l’énergie des radiofréquences. Observez FCC 47 CFR 1.1307 pour l’appréciation de l’environnement, FCC 47 CFR 1.1310 pour les limitations d’exposition des radiofréquences, Code 6 de Sécurité de Santé Canada pour la limite d’exposition aux champs RF, et les autre réglements alliés et de complaisance de la sécurité pour les procédures appropriées de la sécurité, de l’apprentissage, et de l’appréciation.Assurez que le signals d’avertissement appropriés soivant placés appropriatement et affichés dans la location d’équipment ou l’acces d’y entrer.
xxvi © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYCet appareil est conforme au RSS-191 de Industrie Canada. L’utilisation dépend des deux conditions suivantes:nCet appareil ne devrait pas causer d’interférence.nCet appareil doit accepter toute interférence, y compris une interférence pouvant causer une opération indésirable de l’appareil.Cet appareil numerique de la classe B est conforme avec la norme NMB-003 du Canada.
28 GHz SONET OC-3 IFU Installation - R1.0 1-11Installation OverviewThis chapter provides an overview of the installation procedure for the Invisible Fiber™ unit (IFU). In addition, this chapter describes:nIFU Link ManagernPower sourcenCablesnSystem grounding and surge suppression Installation OverviewIFUs are loaded with default system attributes at the factory. At the customer’s designated staging area, the customer-specific attributes, identified in the site database, are downloaded to the IFU, which is then ready for installation. At the installation site, the IFU is installed on a mounting bracket, aligned, and commissioned. When all installation tests are complete and expected results are achieved on all IFU sites, the network is ready for customer acceptance.Site Engineering FolderBefore installing the IFU, the site must be prepared with the appropriate cables, demarcation box, and any equipment as detailed in the site engineering folder. (Refer to the Invisible Fiber™ SONET OC-3 Site Evaluation Guide for details about the contents of the site engineering folder).The site engineering folder is referenced throughout this document. Photos and diagrams of the site are included in the folder.
Installation Overview1-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.IFU Link ManagerThe IFU Link Manager is a local element management software application that helps you configure and commission the IFU. You use this application to complete the following procedures:nIFU configurationnAntenna alignmentnLink commissioning testsPower SourceThe IFUs require a – 48 Vdc power source. The specifications of the power source are defined in the site engineering folder.CablingIFU installations require two types of cables:Power Connects the IFU to the – 48 Vdc power source.Fiber OpticConnects the IFU to the site equipment cabinet.Power CableThe power cable is outdoor/indoor rated. The power cable contains four 12 AWG conductors. Fiber Optic CableFor SONET networks, the IFU requires a multimode/single-mode, fiber optic cable (see Figure 1-1).
System Grounding and Surge Protection28 GHz SONET OC-3 IFU Installation - R1.0 1-3System Grounding and Surge ProtectionThe IFU grounding system has two conceptually distinct, but electrically interconnected functional subsystems, for connection to “earth ground.” The two functional subsystems are:nEarth ground (complies with the National Electrical Code (NEC) for equipment grounding systems).nSurge protection.Earth GroundThe IFU has an external electrical interconnection point for connecting the IFU ground subsystems to earth ground. Surge ProtectionThe sole purpose of surge protection is to transport lightning-related currents to the earth ground. During site installation, surge suppression devices are installed inline with the power and alarm conductors to assist in protecting equipment.
Installation Overview1-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.Figure 1-1. SONET OC-3  Fiber Optic Cable Configuration1234568712345687       PLUGCONNECTION  BULKHEADCONNECTIONCABLE SCHEMATICTRITON NETWORK SYSTEMSSONET  CABLEBLUE     9/1251310 nm1WHITE62.5/125  850 nm8ORANGE     9/1251310 nm23DUMMY4DUMMY5BROWN62.5/125  850 nm6GREY62.5/125  850 nm7PLUGCOLORFIBER TYPEWAVE LENGTH123678(PINS 4 & 5 PLUGGED)(PINS 4 & 5 PLUGGED)GREEN62.5/125  850 nm18234567SCSIGTXTXTXRXRXRXPAYLOADPAYLOADOAM&POAM&PINTERCONNECTINTERCONNECT
28 GHz SONET OC-3 IFU Installation - R1.0 2-12Staging ProcedureThis chapter describes the IFU configuration procedure to be performed at the designated staging area.Configuring IFUsIFUs are configured by using the IFU Link Manager to load the site-specific attributes from the attributes table in the site engineering folder. Table 2-1 identifies the parts needed for configuring a typical IFU site.Table 2-1. Typical IFU Configuration Parts ListItem No. Description Qty.1IFU 12 BNC to banana plug adapter 13 IFU Link Manager test cable  14 Laptop computer with IFU Link Manager installed 15 Power source (– 48 Vdc)  16 IFU power cable 17 Site engineering folder 18 Digital multimeter 1
Staging Procedure2-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.To configure each IFU, complete the following steps:1Remove the IFU from the shipping carton and place it upright on a table with the antenna radome cover facing away from you and the connectors facing you. Verify that the part number on the IFU label matches the attributes table in the site enginering folder. 22380PT-FA00 is a sample part number, where the letters are variables defined as follows:P = Protocol (1=SONET, 2=Ethernet)T = Protocol type (1=OC-3, 2=OC-12, 1=Fast, 2=Gigabit)F = Filter combination for transmit/receive (1/3=1, 2/4=2, 3/1=3, 4/2=4)A = Antenna orientation (Vertical=1, Horizontal=2)CAUTION: Lifting hazard: Two people are required to lift the Invisible Fiber™ unit. Grasp the Invisible Fiber™ unit underneath the lower edge and lift with both hands. To prevent injury, keep your back straight and lift with your legs, not your back. To prevent damage to the Invisible Fiber™ unit and components, never attempt to lift the radio by the attached cables.MISE EN GARDE : Danger de levage. Il faut deux personnes pour soulever l’unité Invisible FiberMD. Saisir l’unité Invisible FiberMD au-dessous du rebord inférieur, puis soulever l’unité avec les deux mains. Pour éviter les lésions corporelles, garder le dos en position verticale et soulever l’unité en utilisant les jambes et non pas les reins. Pour éviter l’endommagement de l’unité Invisible FiberMD et de ses composants, ne jamais essayer de soulever la radio en tirant sur les câbles qui y sont attachés.2238011-1200PRODUCT FREQUENCYFILTER COMBINATIONPROTOCOLANTENNA ORIENTATIONPLACE HOLDER (Future)PROTOCOL TYPEPLACE HOLDER (Future)PRODUCT BLOCK
Configuring IFUs28 GHz SONET OC-3 IFU Installation - R1.0 2-3Figure 2-1. IFU Lifting GuidelineCAUTION: DO NOT lift the Invisible Fiber™ unit by the Radome (front) Cover to avoid damaging the antenna.MISE EN GARDE : NE PAS soulever l’unité Invisible FiberMD par le couvercle du radôme (couvercle avant), afin d’éviter l’endommagement de l’antenne.DANGER – HIGH VOLTAGE HAZARD: Do not work on the system or connect or disconnect cables during periods of lightning activity, rainy weather, or both.DANGER – L’HASARD DU TENSION ÉLEVÉ : Ne pas travailler sur le système ni brancher ni débrancher les câbles durant l’activité de la foudre, par de temps pluvieux, ou tous le deux.DANGER – HIGH CURRENT HAZARD: Ensure that the – 48 Vdc power source is set to the OFF position before beginning the installation procedures for the Invisible Fiber™ unit. DANGER – L’HASARD DU COURANT ÉLEVÉ : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’aborder les procédures pour l’installation de l’unité Invisible FiberMD.34567DCBEFGIFURADOMECOVERLIFTING AREALIFTING AREA
Staging Procedure2-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.2Connect the IFU power cable to the – 48 Vdc power source as shown in Figure 2-2.Figure 2-2. IFU Power Cable Hookup3Set the – 48 Vdc power source to ON. 4Set multimeter to DC voltage.5Connect a black test lead from the negative input of the multimeter to pin C on the IFU power cable (see Figure 2-3).Figure 2-3. Power Test Setup34567DCBEFGIFUPOWERCABLE- 48 VDC POWERSOURCE- 48RTNRTN   WHITE/RED (CABLE PIN C)RTN   WHITE (CABLE PIN H)- 48    WHITE/BLACK (CABLE PIN A)- 48    WHITE/BROWN (CABLE PIN B)CABLE WIRE COLOR CODE34DC567EFDCBEFGTEXTTEXTTEXT T EXTTEXT T EXTTEXT TEXTTEXT TEXTTEXTTEXT- 48+- MULTIMETER IFURTN   CABLE PIN CRTN   CABLE PIN H- 48    CABLE PIN A- 48    CABLE PIN BCABLE PIN ASSIGNMENTIFU POWERCABLEAEDCBHGF
Configuring IFUs28 GHz SONET OC-3 IFU Installation - R1.0 2-56Connect a red test lead from the positive input of the multimeter to pin A on the IFU power cable.7Read the measurement on the multimeter. Passing criteria is – 46 Vdc to – 56 Vdc. 8Connect a black test lead from the negative input of the multimeter to pin H on the IFU power cable.9Connect a red test lead from the positive input of the multimeter to pin B on the IFU power cable.10 Read the measurement on the multimeter. Passing criteria is – 46 Vdc to – 56 Vdc. 11 Set the – 48 Vdc power source to OFF.12 Connect – 48 Vdc power cable to the power connector on the IFU as illustrated in Figure 2-4. DANGER – HIGH CURRENT HAZARD: Do not turn on power before reading the Triton Network Systems’ product documentation. This device has a – 48 Vdc (4 amps operating peak per feed) direct current input.DANGER – L’HASARD DU COURANT ÉLEVÉ : Ne pas mettre la tension avant de lire la documentation du produit fournie par la société Triton Network Systems. Cet appareil a une alimentation directe de – 48 V CC (courant de pointe de 4 ampères par ligne d’alimentation).DANGER – HIGH CURRENT HAZARD: Ensure that the – 48 Vdc power source is set to the OFF position before beginning the installation procedures for the Invisible Fiber™ Unit. DANGER – L’HASARD DU COURANT ÉLEVÉ : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’aborder les procédures pour l’installation de l’unité Invisible FiberMD.
Staging Procedure2-6 © 1999 Triton Network Systems, Inc. All Rights Reserved.Figure 2-4. IFU Configuration Setup13 Set the – 48 Vdc power source to ON.WARNING: Beware! Radio transmitter is ON when the red light indicator on back side of Invisible Fiber™ unit is illuminated. Observe all radio frequency energy exposure and service interruption cautions.MISE EN GARDE : Attention ! Le poste émetteur est EN MARCHE lorsque le témoin rouge sur le dos de l’unité Invisible FiberMD est allumé. Respecter toutes les mises en garde concernant l’exposition aux radiofréquences et l’interruption de service.WARNING – RF EXPOSURE HAZARD: Ensure the safety of all personnel. Do not stand in front of the Invisible Fiber™ unit (antenna) in order to avoid possible harmful radio frequency energy exposure. Serious bodily injury may result.MISE EN GARDE – RF EXPOSURE HAZARD : Assurer la sécurité de tout le personnel. Ne pas rester debout devant l’unité Invisible FiberMD (l’antenne) afin d’éviter toute exposition dangereuse aux radiofréquences. Les lésions corporelles serieux s’ensuivre.34567IFUPOWERCABLE- 48 VDC POWERSOURCE - 48 RTNPC/LINK MANAGERTESTCABLE
Configuring IFUs28 GHz SONET OC-3 IFU Installation - R1.0 2-714 Connect a laptop computer to the IFU as shown in Figure 2-4. 15 Enter the site attributes from the site database into the IFU Link Manager program.NOTE:  Refer to IFU Link Manager help screens to enter the required site database attributes.16 Power down the IFU and remove the cables.NOTE:  If the staging site and the installation site are the same place, continue with Chapter 3, Installation Procedures.17 Confirm that the correct installation address is on the packing box and the packing box label matches the IFU data plate, located on the back of the IFU.18 Use the original packing material to ship the IFU to the installation site. Should the packing material not be available, contact Triton Network Systems (see Contacting Triton Network Systems, Inc. on page xiii) for packing instructions.
Staging Procedure2-8 © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 3-13Installation ProceduresThis chapter provides the procedures for installing IFU components and IFUs.This chapter includes the following topics:nSetupnInstalling IFU componentsnInstalling an IFUThe instructions in this chapter describes the procedure for installing two IFUs. Use the same process to install one IFU or many IFUs; the wiring conventions are the same.NOTE:  Observe all federal and local laws, regulations, electrical codes, building codes, fire codes, and licensing agreements.Il faut respecter l’ensemble des lois, règlements, codes du bâtiment et codes des incendies du gouvernement fédéral et des municipalités ainsi que tous les contrats de licence.NOTE:  Failure to follow the installation procedure described in the Triton Network Systems’ product documentation may result in damage to the Invisible Fiber™ unit and render the unit unusable. Read through the entire installation procedure before beginning installation.L’inobservation de la procédure d’installation décrite dans la documentation du produit fournie par la société Triton Network Systems peut endommager l’unité Invisible FiberMD et la rendre inutilisable.
Installation Procedures3-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.SetupBefore StartingBefore starting the procedures in this chapter, verify that all parts have been received by checking the received items against the equipment and parts lists in the site engineering folder.Preparing for InstallationTable 3-1 identifies the special tools required for installation and Table 3-2 identifies the parts required.Table 3-1. Site Installation ToolsItem No. Description Qty.1 Digital multimeter 12 Fiber cleaning kit (solution & air) 13Fiber scope 14 Fiber tester transmitter 15 Fiber tester receiver 16 Fiber test adapter 27 Site engineering folder 18 Right-angled snap ring pliers (for external snap ring) 1Table 3-2. Site Installation Parts (for two IFUs)Item No. Description Qty.1IFU 22 IFU mounting bracket with snap ring kit 23 IFU power cable 24 Fiber optic cable 25 Tie-wraps, UV-rated A/R
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-3Installing IFU ComponentsThis section describes how to:nMount the IFU bracketnInstall the power cablesnInstall fiber optic cablesMounting the IFU Bracket Using approved engineering methods, mount the IFU bracket in the location specified in the site engineering folder (see Figure 3-1 for typical wall mounting and Figure 3-2 for a typical pole mounting).Figure 3-1. Example of IFU Bracket Attached to Wall 31456452MOUNTING SURFACELEGENDITEM   1   2   3   4   5   6        DESCRIPTIONIFU M0UNTING BRACKETTHREADED ROD*FLAT WASHERSPLIT RING WASHERNUTLARGE FLATWASHERQTY  1  4  4  8  8  4* THREADED ROD LENGTH IS DETERMINED BY WALLTHICKNESS PLUS 2.5 INCHES 102 MM 4.0 IN276 MM10.9 IN    BRACKET HOLE PATTERN       ALLOW 11MM/0.5 IN.          FOR CLEARANCE               (Not to Scale)
Installation Procedures3-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.Figure 3-2. Example of IFU Bracket Attached to PoleNOTE:  Refer to the site engineering folder for location and mount the bracket to the building or pole, using bolts as indicated. NOTE:  Ensure the mounting bracket is mechanically stable, plumb, and level.LEGENDITEM   1   2   3   4   5   6   7        DESCRIPTIONIFU MOUNTING BRACKETMOUNTING POLEBRACKETU-BOLTFLATWASHERLOCK WASHERNUTQTY  1  1  2  2  4  4  45671342
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-5Installing Power CablesThere are two cable routes as follows:nThe IFU Alpha power cable runs from the IFU mounting location to the surge suppression assembly. nThe IFU Beta power cable runs from the IFU mounting location to the surge suppression assembly.To install the IFU power cables:1Route the IFU power cables to a surge suppression assembly according to the site drawing. NOTE:  Allow an extra three-foot service loop at the IFU and twelve inches at each surge suppressor. Use large radius bends to avoid kinking the cables during the cable routing.NOTE:  Connect the cable shields to the suppressor mounting panel. Trim the shield back to the cable breakout and keep the shield as short as possible.2Trim each cable to the appropriate length.3Strip each cable wire to 3/8 inch and tin.4Attach the IFU power cables to the surge suppressors as shown on Figure 3-3, Figure 3-4, and Table 3-3.DANGER – HIGH VOLTAGE HAZARD: Do not work on the system or connect or disconnect cables during periods of lightning activity, rainy weather, or both.DANGER – L’HASARD DU TENSION ÉLEVÉ : Ne pas travailler sur le système ni brancher ni débrancher les câbles durant l’activité de la foudre, par de temps pluvieux, ou tous le deux.CAUTION: Instructions for installing cables are intended for licensed contractors or building maintenance personnel.MISE EN GARDE : Les instructions pour l’installation des câbles sont destinées exclusivement aux entrepreneurs agréés et aux préposés à l’entretien de l’immeuble.
Installation Procedures3-6 © 1999 Triton Network Systems, Inc. All Rights Reserved.Figure 3-3. Typical Power Cable Wiring IFU AlphaSuppressorIFU BetaSuppressorIFU Beta Power CableWhite(PB-2)IFU Alpha Power CableWhite/Black(PA-4)White/Brown(PA-3)White/Red(PA-1)ProtectedShield-+-+White(PA-2) White/Red(PB-1)White/Black(PB-4)White/Brown(PB-3)ShieldProtectedSurge SurgeTable 3-3. Typical Power Cable Wiring IFU AlphaSurge Input Wire Color/Number IFU BetaSurge Input Wire Color/NumberRTN (+) White (PA-2),White/Red (PA-1) RTN (+) White (PB-2),White/Red (PB-1)– 48 (–) White/Black (PA-4),White/Brown (PA-3) – 48 (–) White/Black (PB-4),White/Brown (PB-3)
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-7Figure 3-4. Typical IFU Power Termination Wiring Schematic IFU Power Cable TestTo ensure proper wiring, perform the input power test on both IFU power cables prior to connecting to the IFU. This test ensures that the input power to the IFU is between – 46 Vdc and – 56 Vdc.To test the power cable:RTNWH (PA-2)AIFU AlphaPowerCableWH/BK (PA-4)B- 48 Vdc WH/BN (PA-3)CWH/RD (PA-1)HSuppressorGNDShieldRTNIFU BetaPowerCable - 48 VdcGNDShieldF1 Conn++-PowerSourceF1Common BarF2Common BarF2 ConnShield toChassis GroundSite EquipmentCabinetSurgeProtectedProtectedSurge++++-------White (PB-2)Brown (PB-3)Black (PA-4)Red (PA-1)WhiteRedBrownBlack++ABCHWH (PB-2)WH/BK (PB-4)WH/BN (PB-3)WH/RD (PB-1)Chassis toEarth GroundPanel toEarth GroundDANGER – HIGH VOLTAGE HAZARD: Do not work on the system or connect or disconnect cables during periods of lightning activity, rainy weather, or both.DANGER – L’HASARD DU TENSION ÉLEVÉ : Ne pas travailler sur le système ni brancher ni débrancher les câbles durant l’activité de la foudre, par de temps pluvieux, ou tous le deux.
Installation Procedures3-8 © 1999 Triton Network Systems, Inc. All Rights Reserved.1Set the – 48 Vdc power source to ON.2Set multimeter to DC voltage.3At the mounting location, connect a black test lead from the negative input of the multimeter to pin C on the power cable (see Figure 3-5).Figure 3-5. Power Test Setup4Connect a red test lead from the positive input of the multimeter to pin A on the power cable. Record the results in Table A-1 on page A-1.5Read the measurement on the multimeter. Passing criteria is – 46 Vdc to – 56 Vdc. Record the results in Table A-1 on page A-1.6Connect a black test lead from the negative input of the multimeter to pin H on the power cable.7Connect a red test lead from the positive input of the multimeter to pin B on the power cable.8Read the measurement on the multimeter. Passing criteria is – 46 Vdc to – 56 Vdc. Record the results in Table A-1 on page A-1.Repeat the above test for each IFU power cable.OUTSIDEINSIDEIFU POWERCABLERTN   CABLE PIN CRTN   CABLE PIN H- 48    CABLE PIN A- 48    CABLE PIN BCABLE PIN ASSIGNMENTAEDCBHGFTEXTTEXTTEXT TEXTTEXT TEXTTE XT T E XTTE XT T E XTTEXTTEXT- 48+- MULTIMETER
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-9Installing the Fiber Optic CableThere are two fiber optic cable routes as follows: nThe IFU Alpha fiber optic cable runs from the IFU mounting location to the site equipment cabinet. nThe IFU Beta fiber optic cable runs from the IFU mounting location to the site equipment cabinet.To install the fiber optic cable:WARNING: Never touch exposed fiber with any part of your body. Fiber fragments can enter the skin and are difficult to detect and remove.AVERTISSEMENT : Ne jamais laisser une fibre nue entrer en contact avec une partie quelconque du corps. Des fragments de fibre peuvent entrer dans la peau, et sont difficiles à déceler et à enlever.DANGER: Invisible laser radiation. Avoid direct eye exposure to the end of a fiber, fiber cord, or fiber pigtail. The infrared light used in fiber optics systems is invisible, but can cause serious injury to the eye.AVERTISSEMENT : Rayonnement laser invisible. Éviter l’exposition directe des yeux à l’extrémité d’une fibre, d’un cordon à fibres ou d’une fibre amorce. La lumière infrarouge utilisée dans les systèmes à fibres optiques est invisible, mais peut provoquer des lésions graves aux yeux.CAUTION: Ensure the outside optical fiber connectors are environmentally protected. Failure to do so may cause contamination of the fiber surfaces.MISE EN GARDE : S’assurer que les raccords extérieurs fibre optique sont protégés contre l’environnement. L’absence d’une telle protection peut entraîner la contamination des surfaces des fibres.
Installation Procedures3-10 © 1999 Triton Network Systems, Inc. All Rights Reserved.1Route the IFU fiber optic cables from each of the IFU mounting locations to the site equipment cabinet. Refer to the site drawing in the site engineering folder for the specific route.NOTE:  Allow an extra three-foot service loop at both ends. Use large radius bends to avoid crimping and kinking the cables during the cable routing.2Connect the IFU fiber optic cables to the rear side of the patch panel as shown in Figure 3-6 and Table 3-4.CAUTION: To reduce the risk of fiber optic cable damage, use the following bend radius guidelines for indoor/outdoor fiber optic cable: nLong-term (installed): bend radius is equal to 10 times the diameter of the cable.nShort-term (during installation): bend radius is equal to 20 times the diameter of the cable.MISE EN GARDE : Pour réduire le risque de dommage aux câbles à fibres optiques, suivre les consignes suivantes en matière de rayon de courbure des câbles à fibres optiques extérieurs ou intérieurs : nCourbure à long terme (installée). Le rayon de courbure ne doit pas dépasser 10 fois le diamètre du câble.nCourbure à court terme (pendant l’installation). Le rayon de courbure ne doit pas dépasser 20 fois le diamètre du câble.
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-11Figure 3-6. Demarcation Patch Panel 1A 1B2A 2B3A 3B4A5A4B5B6A 6B7A 7B8A9B8B9A10A 10B11A 11B12A 12BFiber Optic CablesFrom IFUsConnect IFU Fiber Cablesto Rear of PanelPanel FrontConnect Site EquipmentCables to Front of PanelPANELFRONT
Installation Procedures3-12 © 1999 Triton Network Systems, Inc. All Rights Reserved.3Connect the jumpers to the front of the demarcation patch panel as shown in Figure 3-6, Figure 3-7, Figure 3-8 and Table 3-5.Table 3-4. Typical SONET OC-3 Demarcation Panel Input ConnectionsFiber Function FiberColor/NumberRear of Demarcation Panel Fiber TypeIFU Alpha Payload TX Gray (FA-1) 1A Single-ModeIFU Alpha Payload RX White (FA-2) 1B Single-ModeIFU Alpha OAM&P TX Green (FA-3) 2A MultimodeIFU Alpha OAM&P RX Brown (FA-6) 2B MultimodeIFU Alpha Interconnect TX Blue (FA-7) 3A MultimodeIFU Alpha Interconnect RX Orange (FA-8) 3B MultimodeIFU Beta Payload TX Gray (FB-1) 4A Single-ModeIFU Beta Payload RX White (FB-2) 4B Single-ModeIFU Beta OAM&P TX Green (FB-3) 5A MultimodeIFU Beta OAM&P RX Brown (FB-6) 5B MultimodeIFU Beta Interconnect TX Blue (FB-7) 6A MultimodeIFU Beta Interconnect RX Orange (FB-8) 6B Multimode
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-13Figure 3-7. Typical SONET OC-3 Site SchematicIFU AlphaFiberCableGrayDemarcation12BlueWhite36781A1B2A2B3A3B4A4BRear Front1A1B2A2B3A3B4A4BIFU BetaFiberCable1236785A5B6A6B7A7B8A8B5A5B6A6B7A7B8A8B1234IFU AlphaPayloadIFU AlphaOAM&PIFU BetaPayloadIFU BetaOAM&PSite EquipmentCabinetTXRXTXRXTXRXTXRXTXRXTXRXChassis toEarth GroundBrownGreenOrangeBlue (FA-3)Orange (FA-6)Yellow (FB-1)Violet (FB-2)Brown (FB-6)Green (FB-3)Red (FA-1)Black (FA-2)GrayBlueWhiteBrownGreenOrange
Installation Procedures3-14 © 1999 Triton Network Systems, Inc. All Rights Reserved.Figure 3-8. Typical SONET OC-3 Demarcation Jumper LocationsFiber Optic Continuity TestThis test is to ensure that the signal loss in the fiber optic assemblies meet the specifications and that cables have not been damaged during installation. The fiber optic continuity test consists of:nCleaning the fiber optic cablenTesting the fiber optic cable1A 1B2A 2B3A 3B4A5A4B5B6A 6B7A 7B8A9B8B9A10A 10B11A 11B12A 12BTable 3-5. Typical SONET OC-3 Demarcation Panel Jumper ConnectionsFiber Function From To Fiber FunctionIFU Alpha Interconnect TX 3A 6B IFU Beta Interconnect RXIFU Alpha Interconnect RX 3B 6A IFU Beta Interconnect TX
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-15To clean the fiber optic cable:WARNING: Never touch exposed fiber with any part of your body. Fiber fragments can enter the skin and are difficult to detect and remove.AVERTISSEMENT : Ne jamais laisser une fibre nue entrer en contact avec une partie quelconque du corps. Des fragments de fibre peuvent entrer dans la peau, et sont difficiles à déceler et à enlever.DANGER: Invisible laser radiation. Avoid direct eye exposure to the end of a fiber, fiber cord, or fiber pigtail. The infrared light used in fiber optics systems is invisible, but can cause serious injury to the eye.AVERTISSEMENT : Rayonnement laser invisible. Éviter l’exposition directe des yeux à l’extrémité d’une fibre, d’un cordon à fibres ou d’une fibre amorce. La lumière infrarouge utilisée dans les systèmes à fibres optiques est invisible, mais peut provoquer des lésions graves aux yeux.CAUTION: Ensure the outside optical fiber connectors are environmentally protected. Failure to do so may cause contamination of the fiber surfaces.MISE EN GARDE : S’assurer que les raccords extérieurs fibre optique sont protégés contre l’environnement. L’absence d’une telle protection peut entraîner la contamination des surfaces des fibres.
Installation Procedures3-16 © 1999 Triton Network Systems, Inc. All Rights Reserved.1Remove the dust cap on the connector. Using the automatic cleaner, wipe the connector once in each direction across cleaning pad.2With canned air, blow a slow 3 to 4 second burst of air across fiber/ferrule end face to dry connector then replace the dust cap.3Repeat Step 1 and Step 2 on the other end of fiber optic cable.NOTE:  Never leave connectors unprotected after cleaning.4Attach the fiber optic cable to the scope and inspect for dirt, grease, defects, dust, oil, etc.5Repeat Step 1 and Step 2, if necessary.To test the fiber optic cable:1Connect fiber optic test adapters to the IFU Alpha and IFU Beta fiber cables. 2Carefully place the laser receiver IFU Beta test adapter (see Figure 3-9 and Table 3-6).NOTE:  Never connect the transmitter first.CAUTION: To reduce the risk of fiber optic cable damage, use the following bend radius guidelines for indoor/outdoor fiber optic cable: nLong-term (installed): bend radius is equal to 10 times the diameter of the cable.nShort-term (during installation): bend radius is equal to 20 times the diameter of the cable.MISE EN GARDE : Pour réduire le risque de dommage aux câbles à fibres optiques, suivre les consignes suivantes en matière de rayon de courbure des câbles à fibres optiques extérieurs ou intérieurs : nCourbure à long terme (installée). Le rayon de courbure ne doit pas dépasser 10 fois le diamètre du câble.nCourbure à court terme (pendant l’installation). Le rayon de courbure ne doit pas dépasser 20 fois le diamètre du câble.
Installing IFU Components28 GHz SONET OC-3 IFU Installation - R1.0 3-17Figure 3-9. SONET OC-3 Fiber Optic Continuity Test Setup3Connect the transmitter to the IFU Alpha test adapter as called out in Table 3-6. 4Set the transmitter to 0 dBm continuous wave and 1310 nm.5Turn on both units and take readings at the receiver. Record the results in Table A-2 on page A-2.NOTE:  The received signal should be stronger than – 7.4 dBm (less than 7.4 dB).Repeat steps 1 through 5 on each fiber optic cable.Outside BuildingINSIDE BUILDING     LaserTransmitterTest AdapterIFU BetaIFU AlphaDemarcation BoxIFU AlphaFiber CableIFU BetaFiber Cable   LaserReceiverTest Adapter786SONET TEST BOX5MultimodeSingle-Mode12786SONET TEST BOX5MultimodeSingle-Mode12
Installation Procedures3-18 © 1999 Triton Network Systems, Inc. All Rights Reserved.Installing an IFUIFUs are installed in the locations as specified by each site drawing. A near-end IFU is the first installed IFU in a pair, and the far-end IFU is the second in the pair. Figure 3-10 provides a close-up view of an installed IFU. Installing an IFU is a two-part process:1Mounting the IFU to the mounting bracket.2Attaching cables to the IFU.Mounting the IFU Verify the correct IFU for location by checking the product number on the IFU against the site drawing in the site engineering folder. Table 3-6. SONET OC-3 Fiber Test ConnectionsIFU AlphaFiber NameIFU Alpha Test Adapter ConnectorIFU Beta Test Adapter ConnectorIFU Beta Fiber NameIFU Alpha Interconnect TX 7 8 IFU Beta Interconnect RXIFU Alpha Interconnect RX 8 7 IFU Beta Interconnect TXCAUTION: Lifting hazard: Two people are required to lift the Invisible Fiber™ unit. Grasp the Invisible Fiber™ unit underneath the lower edge and lift with both hands. To prevent injury, keep your back straight and lift with your legs, not your back. To prevent damage to the Invisible Fiber™ unit and components, never attempt to lift the radio by the attached cables.MISE EN GARDE : Danger de levage. Il faut deux personnes pour soulever l’unité Invisible FiberMD. Saisir l’unité Invisible FiberMD au-dessous du rebord inférieur, puis soulever l’unité avec les deux mains. Pour éviter les lésions corporelles, garder le dos en position verticale et soulever l’unité en utilisant les jambes et non pas les reins. Pour éviter l’endommagement de l’unité Invisible FiberMD et de ses composants, ne jamais essayer de soulever la radio en tirant sur les câbles qui y sont attachés.
Installing an IFU28 GHz SONET OC-3 IFU Installation - R1.0 3-193Refer to Figure 3-10 and position the IFU (2) on the mounting studs (7) and engage the top clamp.4Install a snap ring (3) on each mounting stud (7). Figure 3-10. Mounting the IFUCAUTION: Keep tools and parts away from walkways. When carrying large, heavy equipment (such as the Invisible Fiber™ unit), obstacles (such as hand tools, cables or components) may not be easily visible and can cause accidents.MISE EN GARDE : Garder les outils et les pièces loin des allées. Lorsqu’on transporte des équipements lourds et à grandes dimensions (tels que l’unité Invisible FiberMD), les obstacles (tels que les outils à main, les câbles ou les composants) sont parfois difficiles à voir et peuvent causer des accidents.345621LEGENDITEM   1   2   3   4   5   6   7           DESCRIPTIONIFU M0UNTING BRACKETIFUSNAP RINGFLAT WASHERLOCK WASHERNUTMOUNTING STUDQTY  1  1  2  1  1  1  2  IFU GROUNDSTRAP7BUILDINGGROUNDSTRAPTOPCLAMP
Installation Procedures3-20 © 1999 Triton Network Systems, Inc. All Rights Reserved.5Position the building ground strap, IFU ground strap, flat washer (4), and lock washer (5) on the bottom bolt of the mounting bracket (1) and install nut (6).
Installing an IFU28 GHz SONET OC-3 IFU Installation - R1.0 3-21Attaching IFU CablesTo test the fiber optic cable:1Connect the power and fiber optic cable to the IFU locations as shown in Figure 3-11. Figure 3-11. IFU Cable Connections2Secure the power and fiber optic cables to the building with tie-wraps as needed.DANGER – HIGH CURRENT HAZARD: Ensure that the – 48 Vdc power source is set to the OFF position before beginning the installation procedures for the Invisible Fiber™ unit. DANGER – L’HASARD DU COURANT ÉLEVÉ : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’aborder les procédures pour l’installation de l’unité Invisible FiberMD.
Installation Procedures3-22 © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 4-14Commissioning ProceduresThis chapter provides the procedures for commissioning IFUsThe following topics are included in this chapter:nAligning the Near-End IFUnCommissioning the Far-End IFUnCommissioning the Near-End IFUnTesting the LinkNOTE:  Observe all federal and local laws, regulations, electrical codes, building codes, fire codes, and licensing agreements.Il faut respecter l’ensemble des lois, règlements, codes d’électrique, codes du bâtiment et codes des incendies du gouvernement fédéral et des municipalités ainsi que tous les contrats de licence.NOTE:  Failure to follow the installation procedure described in the Triton Network Systems’ product documentation may result in damage to the Invisible Fiber™ unit and render the unit unusable.L’inobservation de la procédure d’installation décrite dans la documentation du produit fournie par la société Triton Network Systems peut endommager l’unité Invisible FiberMD et la rendre inutilisable.
Commissioning Procedures4-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.SetupBefore StartingBefore starting the procedures in this chapter, ensure that the IFUs have been mounted at the near-end site and far-end site, and that the cables have been tested.Preparing for InstallationTable 4-1 identifies the basic commissioning tools required for commissioning the near-end and far-end sites.Table 4-1. Site Commissioning ToolsItem No. Description Qty.1 IFU Link Manager test cable  22 IFU Link Manager software 23 Personnel computer with IFU Link Manager installed 24 SONET test set  25 Digital multimeter (measures DC Voltage up to 100V, accuracy 0.3% or better) 26 BNC/banana interface cable 17 Site engineering folder 1
Aligning the IFU28 GHz SONET OC-3 IFU Installation - R1.0 4-3Aligning the IFUTo align the IFU:1Loosen the four vertical alignment screws on the IFU mounting bracket.2Coarse align the near-end IFU to the far-end IFU pair and the far-end IFU to the near-end IFU using an optical alignment tool (see Figure 4-1).Figure 4-1. Coarse Alignment3Loosen the horizontal alignment nut on the holding bracket. Coarse align the near-end IFU to the designated far-end IFU using an optical alignment tool.4Tighten the four vertical screws and single horizontal nut on the IFU mounting bracket.DANGER – HIGH VOLTAGE HAZARD: Do not work on the system or connect or disconnect cables during periods of lightning activity, rainy weather, or both.DANGER – L’HASARD DU TENSION ÉLEVÉ : Ne pas travailler sur le système ni brancher ni débrancher les câbles durant l’activité de la foudre, par de temps pluvieux, ou tous le deux.COARSE ALIGNNEAR-END IFUNEAR-ENDFAR-ENDCOARSE ALIGNFAR-END IFUNEAR-ENDFAR-END
Commissioning Procedures4-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.5Set the – 48 Vdc power source to ON.6Remove the protective cap from the IFU test connector.7Connect the IFU test cable to the test port of the near-end IFU.Figure 4-2. Alignment Test Setup8Connect the BNC plug of the test cable to the BNC/banana interface cable.9Connect the banana plug of the BNC/banana interface cable to the multimeter (red plug to the volt terminal, black plug to the Common terminal).DANGER – HIGH CURRENT HAZARD: Do not turn on power before reading the Triton Network Systems’ product documentation. This device has a – 48 Vdc (4 amps operating peak per feed) direct current input.DANGER – L’HASARD DU COURANT ÉLEVÉ : Ne pas mettre la tension avant de lire la documentation du produit fournie par la société Triton Network Systems. Cet appareil a une alimentation directe de – 48 V CC (courant de pointe de 4 ampères par ligne d’alimentation). IFULAPTOP WITH IFU LINK MANAGERTEXTTEXTTEXT TEXTTEXT TEXTTEXT TEXTTEXT TEXTTEXTTEXT3+- TEST CABLE BNC/BANANAMULTIMETER
Aligning the IFU28 GHz SONET OC-3 IFU Installation - R1.0 4-510 Turn on the multimeter and set it up to measure DC voltage.11 Connect the RJ-45 plug of the test cable to the laptop.12 Power up the laptop and access the IFU Link Manager application. Initialize the IFU if it has not been initialized (refer to IFU Link Manager online help).13 Log on to the near-end IFU.14 Use the IFU Link Manager application to set the near-end IFU radio transmitter to ON (refer to IFU Link Manager online help).15 Ensure that the power control is OFF.Repeat this procedure for the far-end IFU.WARNING: Beware! Radio transmitter is ON when the red light indicator on back side of Invisible Fiber™ unit is illuminated. Observe all radio frequency energy exposure and service interruption cautions.MISE EN GARDE : Attention ! Le poste émetteur est EN MARCHE lorsque le témoin rouge sur le dos de l’unité Invisible FiberMD est allumé. Respecter toutes les mises en garde concernant l’exposition aux radiofréquences et l’interruption de service.WARNING – RF EXPOSURE HAZARD: Ensure the safety of all personnel. Do not stand in front of the Invisible Fiber™ unit (antenna) in order to avoid possible harmful radio frequency energy exposure. Serious bodily injury may result.MISE EN GARDE – RF EXPOSURE HAZARD : Assurer la sécurité de tout le personnel. Ne pas rester debout devant l’unité Invisible FiberMD (l’antenne) afin d’éviter toute exposition dangereuse aux radiofréquences. Les lésions corporelles serieux s’ensuivre.
Commissioning Procedures4-6 © 1999 Triton Network Systems, Inc. All Rights Reserved.Commissioning the IFUTo commission the far-end IFU:1Ensure the near-end IFU transmitter is set to ON.2Loosen the four vertical screws on the holding bracket. 3While viewing the multimeter, sweep the IFU vertically by pointing the IFU all the way up and then down. The measured voltage of the multimeter displays a succession of peak signals as the IFU moves. Specifically, the signal displays a “small” peak, a relatively higher peak, and then redisplays the “small” peak. Note the approximate position of the IFU when the higher peak occurs and the corresponding voltage value. The peak voltage should be approximately 3 Vdc. 4Move the IFU to the higher peak position as indicated by the multimeter display.5Tighten the four vertical screws on the IFU mounting bracket.6Loosen the horizontal alignment nut on the IFU mounting bracket. WARNING: Beware! Radio transmitter is ON when the red light indicator on back side of Invisible Fiber™ unit is illuminated. Observe all radio frequency energy exposure and service interruption cautions.MISE EN GARDE : Attention ! Le poste émetteur est EN MARCHE lorsque le témoin rouge sur le dos de l’unité Invisible FiberMD est allumé. Respecter toutes les mises en garde concernant l’exposition aux radiofréquences et l’interruption de service.WARNING – RF EXPOSURE HAZARD: Ensure the safety of all personnel. Do not stand in front of the Invisible Fiber™ unit (antenna) in order to avoid possible harmful radio frequency energy exposure. Serious bodily injury may result.MISE EN GARDE – RF EXPOSURE HAZARD : Assurer la sécurité de tout le personnel. Ne pas rester debout devant l’unité Invisible FiberMD (l’antenne) afin d’éviter toute exposition dangereuse aux radiofréquences. Les lésions corporelles serieux s’ensuivre.
Commissioning the IFU28 GHz SONET OC-3 IFU Installation - R1.0 4-77Sweep the IFU from the far left to the far right. The measured voltage of the multimeter displays a succession of peak signals as the IFU moves. Note the approximate position of the IFU when the higher peak occurs and the corresponding voltage value. 8Move the IFU to the higher peak position as indicated by the multimeter display.9Tighten the horizontal alignment nut on the IFU mounting bracket.To commission the far-end IFU:1Ensure the far-end IFU transmitter is set to ON.2Loosen the four vertical screws on the IFU mounting bracket. 3While viewing the multimeter, sweep the IFU vertically by pointing the IFU all the way up and then down. The measured voltage of the multimeter displays a succession of peak signals as the IFU moves. Specifically, the signal displays a “small” peak, a relatively higher peak, and then redisplays the “small” peak. Note the approximate position of the IFU when the higher peak occurs and the corresponding voltage value. The peak voltage should be approximately 3 Vdc. WARNING: Beware! Radio transmitter is ON when the red light indicator on back side of Invisible Fiber™ unit is illuminated. Observe all radio frequency energy exposure and service interruption cautions.MISE EN GARDE : Attention ! Le poste émetteur est EN MARCHE lorsque le témoin rouge sur le dos de l’unité Invisible FiberMD est allumé. Respecter toutes les mises en garde concernant l’exposition aux radiofréquences et l’interruption de service.WARNING – RF EXPOSURE HAZARD: Ensure the safety of all personnel. Do not stand in front of the Invisible Fiber™ unit (antenna) in order to avoid possible harmful radio frequency energy exposure. Serious bodily injury may result.MISE EN GARDE – RF EXPOSURE HAZARD : Assurer la sécurité de tout le personnel. Ne pas rester debout devant l’unité Invisible FiberMD (l’antenne) afin d’éviter toute exposition dangereuse aux radiofréquences. Les lésions corporelles serieux s’ensuivre.
Commissioning Procedures4-8 © 1999 Triton Network Systems, Inc. All Rights Reserved.4Move the IFU to the higher peak position as indicated by the multimeter display.5Tighten the four vertical screws on the IFU mounting bracket.6Loosen the horizontal alignment nut on the IFU mounting bracket. 7Sweep the IFU from the far left to the far right. The measured voltage of the multimeter displays a succession of peak signals as the IFU moves. Note the approximate position of the IFU when the higher peak occurs and the corresponding voltage value. 8Move the IFU to the higher peak position as indicated by the multimeter display.9Tighten the horizontal alignment nut on the IFU mounting bracket.10 Access the IFU Link Manager application and enable Power Control for both the near-end and the far-end IFUs (see IFU Link Manager online help).11 Record the minimum, maximum, and actual RSSI levels set for the IFU in Table A-3 and Table A-5. 12 Turn off the laptops, disconnect the test cables, and replace the protective caps on the IFU test connectors.13 Secure all IFU cabling with UV-rated tie-wraps. Continue to tie wrap the cables every 18 inches until they enter the building.SONET OC-3 Link Performance TestThis test verifies the continuity of the optical fiber signal path end to end.To perform the Link Performance Test:1Configure both SONET test sets for OC-3 testing and connect fiber patch cables as shown in Figure 4-3.2Test sets will sync up with each other and run head to head. Record the results in Table A-5.3Configure both SONET test sets for DS-3 testing and connect fiber patch cables as shown in Figure 4-3.4Test sets will sync up with each other and run head to head. Record the results in Table A-5.
SONET OC-3 Link Performance Test28 GHz SONET OC-3 IFU Installation - R1.0 4-95Set up both SONET test sets for DS-1 testing.6Test sets will sync up with each other and run head to head. Record the results in Table A-5.7A frame/bit error can be injected and received to further demonstrate a good path during all tests.8If all tests run error free and the cabling and termination are correct, all tests pass.Figure 4-3. SONET Link Test SetupFAR-END IFU  NEAR-END IFUPROTECTEDPAYLOADPAYLOADSONET TEST SETOUTSIDE BUILDINGINSIDE BUILDINGOUTSIDE BUILDINGINSIDE BUILDINGBLUERECEIVERX TXORANGETRANSMITIFU A IFU BPATCH PANELSONET TEST SETBLUERECEIVERX TXORANGETRANSMITIFU A IFU BPATCH PANEL
Commissioning Procedures4-10 © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 5-15Removing an IFUThis chapter provides the procedures for removing an IFU. The following topics are included in this chapter:nServicing an IFUnRemoving an IFUNOTE:  Observe all federal and local laws, regulations, electrical codes, building codes, fire codes, and licensing agreements.Il faut respecter l’ensemble des lois, règlements, codes d’électrique, codes du bâtiment et codes des incendies du gouvernement fédéral et des municipalités ainsi que tous les contrats de licence.NOTE:  Failure to follow the installation procedure described in the Triton Network Systems’ product documentation may result in damage to the Invisible Fiber™ unit and render the unit unusable. Read through the entire installation procedure before beginning installation.L’inobservation de la procédure d’installation décrite dans la documentation du produit fournie par la société Triton Network Systems peut endommager l’unité Invisible FiberMD et la rendre inutilisable.CAUTION: The Invisible Fiber™ unit contains no owner or user serviceable parts. Opening the radio unit or tampering with any of its seals voids all warranties.MISE EN GARDE : L’unité Invisible Fibermd contient pas de parts utilés par le propriétaire ou l’usager. Ouverture de l’unité de la radio ou toucher aux scelles rend toute garantie nulle et non avenue.
Removing an IFU5-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.Servicing an IFUServicing an IFU is done at the factory. To service the IFU, remove it and replace it with a new IFU.  Send the IFU needing service to the factory.Removing an IFU Removing an IFU is a two-part process:1Removing the power and cables from the IFU.2Removing the IFU from the mounting bracket.Removing CablesTo remove power and cables from the IFU:CAUTION: Ensure that the – 48 Vdc power source is set to the OFF position before attaching power cables to the Invisible Fiber™ Unit.MISE EN GARDE : S’assurer que le bloc d’alimentation – 48 V CC est en position HORS TENSION avant d’attacher les câbles d’alimentation à l’unité Invisible Fibermd.WARNING: Never touch exposed fiber with any part of your body. Fiber fragments can enter the skin and are difficult to detect and remove.AVERTISSEMENT : Ne jamais laisser une fibre nue entrer en contact avec une partie quelconque du corps. Des fragments de fibre peuvent entrer dans la peau, et sont difficiles à déceler et à enlever.
Removing an IFU28 GHz SONET OC-3 IFU Installation - R1.0 5-31Set the – 48 Vdc power source to the OFF position.2Remove the power and fiber optic cables from the IFU locations as shown in Figure 5-1.Figure 5-1. IFU Cable ConnectionsCAUTION: Ensure the outside optical fiber connectors are environmentally protected. Failure to do so may cause contamination of the fiber surfaces.MISE EN GARDE : S’assurer que les raccords extérieurs fibre optique sont protégés contre l’environnement. L’absence d’une telle protection peut entraîner la contamination des surfaces des fibres.
Removing an IFU5-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.Removing an IFU from a Mounting BracketTo remove an IFU from its mounting bracket:1Remove the nut (6), lock washer (5), flat washer (4), and earth ground strap from the bottom bolt of the mounting bracket (1) (see Figure 5-2). 2Remove two snap rings (3) from mounting studs (7) as shown in Figure 5-2.3Disengage the top IFU clamp and remove the IFU (2) from the mounting bracket (1) as shown in Figure 5-2.4Replace dust caps on exposed IFU and cable connectors. CAUTION: Lifting hazard: Two people are required to lift the Invisible Fiber™ unit. Grasp the Invisible Fiber™ unit underneath the lower edge and lift with both hands. To prevent injury, keep your back straight and lift with your legs, not your back. To prevent damage to the Invisible Fiber™ unit and components, never attempt to lift the radio by the attached cables.MISE EN GARDE : Danger de levage. Il faut deux personnes pour soulever l’unité Invisible FiberMD. Saisir l’unité Invisible FiberMD au-dessous du rebord inférieur, puis soulever l’unité avec les deux mains. Pour éviter les lésions corporelles, garder le dos en position verticale et soulever l’unité en utilisant les jambes et non pas les reins. Pour éviter l’endommagement de l’unité Invisible FiberMD et de ses composants, ne jamais essayer de soulever la radio en tirant sur les câbles qui y sont attachés.CAUTION: Keep tools and parts away from walkways. When carrying large, heavy equipment (such as the Invisible Fiber™ Unit), obstacles (such as hand tools, cables or components) may not be easily visible and can cause accidents.MISE EN GARDE : Garder les outils et les pièces loin des allées. Lorsqu’on transporte des équipements lourds et à grandes dimensions (tels que l’unité Invisible FiberMD), les obstacles (tels que les outils à main, les câbles ou les composants) sont parfois difficiles à voir et peuvent causer des accidents.
Packing the IFU for Shipment28 GHz SONET OC-3 IFU Installation - R1.0 5-5Figure 5-2. IFU Removal5To install a new IFU see Mounting the IFU on page 3-18 and Attaching IFU Cables on page 3-21.Packing the IFU for ShipmentUse the original packing material to ship the IFU to the factory. Should the packing material not be available, contact Triton Network Systems (see Contacting Triton Network Systems, Inc. on page xiii) for packing instructions.345621LEGENDITEM   1   2   3   4   5   6   7           DESCRIPTIONIFU M0UNTING BRACKETIFUSNAP RINGFLAT WASHERLOCK WASHERNUTMOUNTING STUDQTY  1  1  2  1  1  1  2  IFU GROUNDSTRAP7BUILDINGGROUNDSTRAPTOPCLAMP
Removing an IFU5-6 © 1999 Triton Network Systems, Inc. All Rights Reserved.
28 GHz SONET OC-3 IFU Installation - R1.0 A-1AIFU Test ResultsThis appendix contains tables for recording the power, fiber optic, and commissioning test data.Power Source TestsTable A-1. Power Supply Test ResultsPins Results Pass Criteria Pass/FailIFU Alpha - A & C – 46 Vdc to – 56 VdcIFU Alpha - B & H – 46 Vdc to – 56 VdcIFU Beta - A & C – 46 Vdc to – 56 VdcIFU Beta - B & H – 46 Vdc to – 56 VdcIFU Gamma - A & C – 46 Vdc to – 56 VdcIFU Gamma - B & H – 46 Vdc to – 56 Vdc
IFU Test ResultsA-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.SONET OC-3 Fiber Optic Test Far-End Test  Near-End Test Table A-2. SONET OC-3 Fiber Optic Test ResultsIFU Alpha Test Adapter End Fiber Signal Strength>–7.4 dBm  @ 1310 nm IFU Beta Test Adapter EndIFU Alpha Interconnect TX IFU Beta Interconnect RXIFU Alpha Interconnect RX IFU Beta Interconnect TXTable A-3. Far-End Test Results #1IFU Number Min/MaxSignal StrengthIFU Signal Strength Set Pass/FailTable A-4. Far-End Test Results #2IFU Number Min/MaxSignal StrengthIFU Signal Strength Set Pass/FailTable A-5. Near-End Test Results #1IFU Number Min/MaxSignal StrengthIFU Signal Strength Set Pass/Fail
SONET OC-3 Link Performance Test28 GHz SONET OC-3 IFU Installation - R1.0 A-3 SONET OC-3 Link Performance Test Table A-6. Near-End Test Results #2IFU Number Min/MaxSignal StrengthIFU Signal Strength Set Pass/FailTable A-7. SONET OC-3 Link Performance TestTest Errors Received(Expect 0 Errors) Errors Sent(Expect 0 Errors)OC-3DS-1DS-3
IFU Test ResultsA-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.
Product Glossary - R0.1 glossary-5CONFIDENTIAL & PROPRIETARYDO NOT COPYInvisible Fiber™ Product Glossary10BaseFLPart of the IEEE 802.1j standard for 10 Mbps Ethernet fiber.10BaseTIEEE 802.3 standard specifying Ethernet over unshielded twisted pair cables.99.999% availability (Also known as five 9s availability.) Amount of time the system is expected to be available. If the system is available 99.999% of the time, expected down time is approximately six minutes per year, derived as follows:Days per year X hours per day X (100–99.999) ÷ 100 X 60 =365.25 X 24 X (100–99.999) ÷ 100 X 60 = 5.2 minutes100BaseFXPart of the IEEE 802.3u standard for 100 Mbps Ethernet over fiber.AAdd/Drop Multiplexer (ADM)A device that provides an interface between the different signals in a digital T-carrier or SONET network. When an ADM is inserted in a transmission line, it enables lower rate signals to be extracted (dropped) and transported differently (electrical or optical). Similarly, a lower rate signal can be inserted (added) into a higher rate signal.ADD/DROPMULTIPLEXERSignals added and droppedat an intermediate point in  the transmission (via a multiplexer)Communication Flow
glossary-6 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYADMSee Add/Drop Multiplexer (ADM). AISSee Alarm Indication Signal (AIS). Alarm Indication Signal (AIS)A special signal that is transmitted to downstream equipment for specific equipment fault conditions.antennaA mechanical device that can convert electrical signals to and from electromagnetic waves. An IFU contains an antenna.Asynchronous Transfer Mode (ATM)A cell-based protocol, developed by the ITU-T, for transmitting and switching voice, video, and data traffic. ATM technology does not use a fixed timing reference, hence the name asynchronous.ATMSee Asynchronous Transfer Mode (ATM).atmospheric absorptionAmount of energy lost when radio waves are transmitted due to the presence of atmospheric gases. attenuationThe reduction in the strength of a signal measured in dB. See also propagation loss. azimuthThe horizontal angle the radiating lobe of an antenna makes. When you adjust an IFU by its azimuth, you move it on its horizontal plane (left to right or right to left).BbackboneA backbone is the transport path that provides connectivity to other paths. On the Internet or a WAN, the backbone is a series of paths to which local, regional, or global networks connect.
Product Glossary - R0.1 glossary-7CONFIDENTIAL & PROPRIETARYDO NOT COPYbackhaulA transmission path used to move traffic to/from a remote location from/to a central location. The message can be routed “out of its way” so that it arrives at its destination more quickly. A network can perform a back haul transmission if a direct communication link is busy and an indirect link would be faster. (The verb form is back haul.)bandwidthThe range of frequencies over which a signal is transmitted.BERSee Bit Error Rate (BER).Bit Error Rate (BER)The number of bit errors detected – displayed as the ratio of the average number of errored bits in a given number of bits sent. The BER is used to measure transmission quality. For example, a BER of 10–12 is equivalent to one error in a trillion bits, which means that for:nSONET OC-3, one error bit is detected approximately every 1.8 hoursnFast Ethernet, one error bit is detected approximately every 2.8 hours.BNC connectorBayonet Neil-Concelman connector. A bayonet type of connector for coaxial cables in an Ethernet network.CCentral Office (CO)Location at which one or more switches reside for aggregating voice or data traffic.Central Processing Unit (CPU)Central controller that coordinates functions in the IFU.channelPhysical medium through which signals are transmitted. In optical fiber transmissions, a channel is a separate wavelength of light within a combined multiplexed light stream.channelizationLogically subdividing a frequency (normally assigned by a regulatory agency for the delivery of broadband wireless services).
glossary-8 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYCLECIndependent company that competes with the already established local telephone company by providing its own network and switching. CLEC distinguishes a new or potential competitor from an established local exchange carrier (LEC). The term originated from the Telecommunications Act of 1996, which was intended to promote competition among long-distance and local phone service providers.COSee Central Office (CO).cochannel interferenceInterference between signals transmitted within one radio frequency channel.colocationSpace set aside for a customer’s telecommunications equipment on the service provider’s premises. For example, a web site owner could place its computer server on the premises of an ISP, or an ISP could locate its network router at a company that supplies switching services to other ISPs. Competitive Local Exchange Carrier See CLEC.commissioningTasks required to enable equipment to be placed in a live network. IFU commissioning tasks include configuration and antenna alignment.configuration managementThe process of setting equipment attributes that enables equipment to function as intended.consecutive pointNetwork architecture implemented via a point-to-point-to-point design.CPESee Customer Premise Equipment (CPE).CPUSee Central Processing Unit (CPU).Customer Premise Equipment (CPE)Equipment (such as telephones and computers) installed at a customer’s office.customer siteNetwork equipment configuration for a location at which network access is provided in a carrier’s consecutive point network.
Product Glossary - R0.1 glossary-9CONFIDENTIAL & PROPRIETARYDO NOT COPYCrane rain modelSystem of formulas, charts, and maps developed by Robert K. Crane to depict a global prediction of attenuation caused by rain. See also rain attenuation.DdBDecibel. The unit of measurement for signal strength, usually the ratio between a transmitted signal and a standard signal source.decibel (dB)See dB.demarcation pointLogical dividing point between equipment and a network.EElement Management System (EMS)Software application used to manage network equipment.EMSSee Element Management System (EMS).EthernetGeneric term for the IEEE 802.3 standard network transmission protocol.exciterAn oscillator that enables a tuner to change its frequency.Ffade marginAmount of signal reduction a receiver can tolerate and continue to maintain satisfactory performance.far-end IFUa) IFU at the other end of the link in the network (during site evaluation).b) Second IFU installed in a linked pair of IFUs.See also near-end IFU.Fast EthernetGeneric term for a IEEE standard network 100 Mbps transmission protocol.fault managementSoftware that reports and identifies the source of network faults.
glossary-10 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYfiber opticsTechnology in which information is transmitted as light impulses from one point to another through extremely thin glass or plastic wire or fiber.fixed wireless systemCommunication system that uses radio spectrum to provide services to locations that are not mobile.forward error correctionA system in which redundant information is generated at the transmitted end so that the receiving unit can detect, locate, and correct any errors before delivering the transmission.free space propagation lossNormal signal attenuation of radio waves transmitted through free space. Free space loss increases logarithmically with increased hop distance. Fresnel zoneA defraction zone around the line-of-sight path between two points as shown in the following illustration.The line-of-sight, including the Fresnel zone, must be clear of obstructions to ensure communication between the IFUs.GgatewayA network point that aggregates traffic and acts as an entrance to another network.gateway siteNetwork equipment configuration for a location that aggregates customer traffic in a consecutive point network for access to and from the Internet.general purpose input/outputSee GPIO.2 MilesFresnel Zone
Product Glossary - R0.1 glossary-11CONFIDENTIAL & PROPRIETARYDO NOT COPYGPIOGeneral Purpose Input/Output. Input/output ports on the IFU that provide external control of equipment or detection and generation of external alarms. Each IFU contains four GPIO ports (two input-only and two output-only).HhistogramA graphical representation of the distribution of a performance parameter. For example, a histogram can show the value and proportion of time a particular transmit power is used on a link.hop distanceThe distance between two communicating IFUs. One objective in network design is to design link hop distances so that the RF path loss does not exceed the path loss allowance for the required availability or grade of service.HP OpenView™Hewlett Packard’s network management product consisting of a suite of software tools that enable network operations staff to manage the elements in a network. HP OpenView Network Node Manager™ and the IFU Link Manager software provide complete element management functions for an IFU network.hubA location in a network where data is aggregated and forwarded to its destination. A hub contains a switch and a router.IIFUInvisible Fiber™ unit. Outdoor fixed-wireless device, designed to fiber-optic specifications, that combines antenna, transceiver, modem, and controller modules to transport high-bandwidth network-grade broadband telephony and data services.IFU Link ManagerTriton Network Systems’ software application that provides fault, performance, configuration, and security management functions, enabling onsite technicians and network management staff to configure and monitor IFUs.ILECIncumbent Local Exchange Carrier. Generic term for the carrier that telephone company in the U.S. that was providing local service when the Telecommunications Act of 1996 was enacted.
glossary-12 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYIn Service (IS)System status indicating that an IFU is working with no known problems.Incumbent Local Exchange CarrierSee ILEC.indoor repeater siteLocation used to extend a consecutive point network to enable future customer access.Internet ProtocolSee IP.Internet Service Provider (ISP)An operator that provides its customers access to the Internet.Invisible Fiber™ unitSee IFU.IPInternet Protocol. A connectionless network layer protocol used for forwarding individual packets from one intermediate destination (typically a router) to another on the way to their final destination.ISSee In Service (IS).ISPSee Internet Service Provider (ISP).ITU rain modelSystem of formulas, charts, and maps developed the International Telecommunication Union (ITU) to characterize rain attenuation.JJava™A C++-like, object-oriented programming language, created by Sun Microsystems and used to build client and server applications that run on any hardware platform where a Java virtual machine resides. Java™ Runtime EnvironmentSee JRE.JREJava™ Runtime Environment. Software platform that enables Java applications to execute. The IFU Link Manager software requires JRE.
Product Glossary - R0.1 glossary-13CONFIDENTIAL & PROPRIETARYDO NOT COPYJava™ virtual machineSoftware, created for specific hardware platforms (microprocessors), that interprets compiled Java code (bytecode) using the microprocessor’s set of instructions. Java virtual machines enable any Java application (bytecode) to run on any platform without requiring the programmer to rewrite or recompile the application for each platform. LLANLocal Area Network. Integrated data communication network (linking computers and peripheral devices) designed to provide services to a closed user community. See also MAN and WAN.line-of-sightStraight line of space between a transmitter and receiver. The space between a transmitter and receiver must be clear of obstructions because the transmission media (such as microwave, infrared, and laser) travel in a perfectly straight line.link anglesGPS coordinates of the angle for an IFU linked pair.link budgetThe sum of transmission losses between transmitter and receiver. The total should be equal to or less than the system gain. The link budget is configured using the transmitted signal power and signal-to-noise ratio (SNR), the antenna gains, implementation degradation, and the noise figure of the receiver.link managerSee IFU Link Manager.LMDSSee Local Multipoint Distribution System (LMDS). Local Area Network (LAN)See LAN.Local Multipoint Distribution System (LMDS)Broadband wireless spectrum over which telephony and data services are delivered.loop backDirecting signals back toward the transmitting device at some point along the communications path. Used as a method for troubleshooting.
glossary-14 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYMMANMetropolitan Area Network. Integrated data communication network within a city. See also LAN and MAN.Management Information BaseSee MIB.MIBManagement Information Base. A collection of statistics and variables residing on an SNMP-managed device. The statistics allow collection of performance data and the variables allow configuration of the device.microwave radioDevice that uses microwave frequencies (3–300 GHz) for consecutive point communication.Millimeter WaveSee MMW.MMICSee Monolithic Microwave Integrated Circuit.MMWMillimeter Wave. The frequency range between 30 and 300 GHz. modemMOdulator, DEModulator. A device that converts between analog and digital signaling. modulationAct of encoding information onto a carrier signal.Monolithic Microwave Integrated CircuitIntegrated circuit technology that provides two-watt linear power at the Tx port of the RF power amplifier.multiplexerDevice that aggregates traffic into a single medium.NNENetwork Element. Single piece of equipment in the network.
Product Glossary - R0.1 glossary-15CONFIDENTIAL & PROPRIETARYDO NOT COPYnear-end IFUa) IFU at the location being evaluated.b) First IFU installed in a linked pair of IFUs.See also far-end IFU.Network ElementSee NE.Network Interface CardSee NIC.network managementThe policies, procedures, and tools that enable an operator to monitor and manage network elements.Network Management System (NMS)Integrated, comprehensive system of equipment used for monitoring and managing network elements.Network Operations Center (NOC)Location at which monitoring and management of a network might take place.network provisioningAct of configuring IFU network hardware and software to make the network operational.NICNetwork Interface Card. Interface between physical transmitter layer and modem.NMSSee Network Management System (NMS). NOCSee Network Operations Center (NOC).NREPNot REPorting. System status indicating the IFU is not reporting alarms because an operator has suspended alarm reporting.NRESNot RESponding. System status indicating the IFU is not responding to poll messages from HAMLET.
glossary-16 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYOOAM&POperations, Administration, Maintenance, and Provisioning. Describes a piece of equipment or personnel required to manage a network.OC-3Optical Carrier level 3. Optical signal designed to receive and transmit SONET. A pure OC-3 SONET channel carries 155.52 Mbps.OC-12Optical Carrier 12. Optical signal designed to receive and transmit SONET. A pure OC-12 SONET channel carries 622.08 Mbps.OC-48Optical Carrier level 48. Optical signal designed to receive and transmit SONET. A pure OC-48 SONET channel carries 2.4 Gbps.OOSOut Of Service. System status indicating that the IFU is currently not in service and is not expected to recover on its own. Service is required.operating systemSee OS.OSOperating System. Program that loads when a computer is booted and manages all the other applications in the computer.outdoor repeater siteLocation used to extend a consecutive point network.PpasswordA string of characters entered by a user, typically in a Login screen, to gain access to a computer system.path loss allowanceThe net amount of amplification given to the signal in an IFU link, including margins for adequate received SNR and channel fading. In other words, path loss allowance is equal to the system gain plus the antenna gains.payloadUser traffic transported over a network
Product Glossary - R0.1 glossary-17CONFIDENTIAL & PROPRIETARYDO NOT COPYPoint Of Presence (POP)Umbrella name referring to the location of the physical access point where user traffic is aggregated. polarizationDirectional orientation of a radio wave electric field. Some radio communication systems can exploit polarization differences to reduce interference from nearby links.POOSPotentially Out Of Service. System status indicating that the IFU is in service, but may be out of service in the future. Service may be required.POPSee Point Of Presence (POP).power sourceA separate unit or part of a circuit that supplies power to the rest of the circuit or to a system. propagation lossSignal attenuation that occurs during transmission.provisioningAct of configuring the gateway routers and the site equipment to enable a customer to receive service.QQAMQuadrature Amplitude Modulation. Transmitted signal defined by amplitude and phase.RRadio Frequency (RF)An electromagnetic wave frequency from approximately 3 KHz to approximately 300 GHz. Includes the frequencies used for radio and television transmission.radio overheadIFU communication channel in addition to the payload.rain attenuationTransmit signal loss due to rain.
glossary-18 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYReceived Signal Strength IndicatorSee RSSI.receiverTelecommunication equipment device that captures and converts a transmitted signal to the required format.reference oscillatorA device that generates a precise radio frequency signal to be used as a reference.RFSee Radio Frequency (RF).RF spectrumRange of available radio frequencies.routerA layer-3 physical device that aggregates and directs network traffic based on TCP/IP.RS-232Recommended standard physical interface (connector) for electrical, functional, and mechanical communication interfaces between computers, terminals, and modems.RSLSee RSSI.RSSIReceived Signal Strength Indicator (also known as RSL, Received Signal Level). A measured value from a receiver describing the received signal level or strength. Ssecurity managementSystem to protect a network from invalid access.Signal Quality Metric (SQM)Ratio of bit energy to noise power spectral density. The SQM value relates to transmission and receiver signal quality.Simple Network Management ProtocolSee SNMP.
Product Glossary - R0.1 glossary-19CONFIDENTIAL & PROPRIETARYDO NOT COPYsite drawingGraphic depiction, which shows the location of all IFU-related components drawn by a contractor and designee. A site drawing is a component of a site engineering folder.site engineering folderDocumentation generated by Triton Network Systems based on the information gathered during the site survey and product requirement specifications.SNMPSimple Network Management Protocol. An industry standard protocol used to communicate between elements and management systems in a network.SONETSynchronous Optical NETwork. Standard protocol that defines a group of fiber-optic transmission rates that can transmit various bit-rate signals inside a broadband synchronous signal. SONET was designed to allow for a multi-vendor environment.SNRSignal-to-Noise Ratio. The SNR measures the quality of the intended signal versus any background noise. Usually expressed in decibels (dB).SQMSee Signal Quality Metric (SQM).stagingInstallation phase during which equipment might be integrated and made ready for deployment.switchA network device that selects the path for sending traffic to its next destination.Synchronous Optical NETworkSee SONET.system gainThe ratio of transmit power to receiver sensitivity, usually expressed in dB. This ratio usually does not include antenna gain.
glossary-20 © 1999 Triton Network Systems, Inc. All Rights Reserved.CONFIDENTIAL & PROPRIETARYDO NOT COPYTTCMTrellis Coded Modulation. The goal of TCM is the same as other error correction schemes – to increase data rate by adding redundancy to reduce error. TCM uses redundancy to enhance the signal detection process.TCP/IPTransmission Control Protocol/Internet Protocol. Family of data communication protocols universally implemented on the Internet.TCP is a transport layer protocol used for reliable, connection-oriented communication between two applications. SNMP is a commonly used protocol in the TCP/IP family.TOOSTemporarily Out Of Service. System status indicating the IFU is out of service, but is expected to recover without human intervention.transceiverAbbreviation for a transmitter and receiver.transmitterDevice that converts signals for transmission.Trellis encoding rateRate of TCM. (See TCM.)TxTransmitted signal or transmitter. VVirtual Private NetworkSee VPN.VPNVirtual Private Network. Private network that is built on top of a public network.WWANWide Area Network. High-speed network that connects networks over a large geographical area. (See also LAN and MAN.)Wide Area NetworkSee WAN.
28 GHz SONET OC-3 IFU Installation - R1.0 index-1IndexAaligningnear-end IFU 4-3Bbracketattached to wall 3-3mounting 3-3pole mount 3-4removing IFU from 5-4Ccable 1-2connections 3-21fiber optic 1-2continuity test 3-14–3-18continuity test results form A-2power 1-2input test 3-7–3-8input test results form A-1verify connection 2-4–2-5removing 5-2verify connectionsetup 2-4cautionspersonal injury xviiconvention xvservice interruption xviiiconvention xvcleaningfiber optic cableprocedure 3-15commissioningsetup 4-2commissioning tools 4-2componentsfiber optic cable, installing 3-9IFU bracket, mounting 3-3power cables, installing 3-5configuration 2-1defined 2-1parts list 2-1procedure 2-2setup 2-6staging areacontacting Triton Network Systems, Inc. xiiiconventionswarnings and safetyEnglish xvfiber optic warning xvFrench xxirisk of electrical shock xvrisk of personal injury xvrisk of radio frequency energy exposure xvrisk of service interruption xvDdangerfiber optics xvihigh current hazard xvihigh voltage hazard xvidemarcation jumper cables 3-14demarcation panelconnections 3-11Eearth ground 1-3
index-2 © 1999 Triton Network Systems, Inc. All Rights Reserved.electrical shock warnings xviconvention xvengineering folder 1-1Ffar-end IFUdefined 3-18test 4-8results form A-2fiber optic cable 1-2cleaning procedure 3-15configuration 1-4continuity test 3-14–3-18results form A-2installing 3-9testing procedure 3-16, 3-21fiber optic warnings xviconvention xvGgounding systemearth ground 1-3IIFUaligning near-end 4-3bracketSee bracketcommissioningfar-end 4-6far-end test 4-8far-end test results form A-2near-end test results form A-2installing 3-18mounting 3-18part number 2-2pole setup 3-4power terminationwiring diagram 3-7removing from bracket 5-4servicing 5-2wall mount setup 3-3IFU Link Managerdefined 1-2for commissioning 4-2installationattaching cables to IFU 3-21cable requirements 1-2fiber optic cable 3-9IFU 3-18IFU components 3-3fiber optic cable 3-9power cable 3-5mounting IFU on bracket 3-18overview 1-1power cables 3-5power source requirements 1-2setup 3-2Jjumperdemarcation box connections 3-14jumper cablesdemarcation 3-14Llifting guideline 2-3lightning suppression 1-3link performance test 4-8results forms A-3setup 4-9Mmaintenance 5-2mises en garde xxvmountingIFU 3-18IFU bracket 3-3NNational Electrical Code (NEC) 1-3near-end IFUaligning 4-3defined 3-18testresults form A-2Ooptical fiberSee fiber optic
28 GHz SONET OC-3 IFU Installation - R1.0 index-3Ppart number 2-2parts listconfiguration 2-1site installation 3-2performance test, link 4-8results forms A-3performance test, link setup 4-9personal injurycautions xviielectrical shock warnings xvifiber optics warnings xvipole mount 3-4power cable 1-2hookup 2-4IFU power terminationwiring diagram 3-7input testsetup 3-8installing 3-5testresults form A-1verify connection 2-4–2-5wiring diagram 3-6power source 1-2precautions xixprocedurealigning near-end IFU 4-3configuration 2-2fiber optic cablecleaning 3-15testing 3-16, 3-21installing fiber optic cable 3-9cleaning 3-15testing 3-16, 3-21installing power cables 3-5link performance test 4-8mounting IFU bracket 3-3removing cables 5-2removing IFU from bracket 5-4Rradio frequencyenergy exposureconvention xvwarnings xviremovingIFU cables 5-2IFU from bracket 5-4riskelectrical shockconvention xvwarnings xvifiber opticsconvention xvwarnings xviother precautions xixpersonal injurycautions xviiconvention xvradio frequency energy exposureconvention xvwarnings xviservice interruptioncautions xviiiconvention xvrisquecâbles à fibres optiques xxiiconvention xxid’interruption de service xxivconvention xxide lésions corporelles xxiiiconvention xxidécharge électrique xxiiconvention xxil’exposition de l’énergie radiofréquences xxiiiconvention xxiSservice 5-2setupcommissioning IFUs 4-2configuration 2-6installing IFUs 3-2pole mounted bracket 3-4verify connection 2-4wall mounted bracket 3-3site engineering folder 1-1site equipment cabinetinputs 3-13site installationparts list 3-2tools 3-2SONET 1-2stagingSee configuration
index-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.surge suppression 1-3defined 1-3system groundingSee grounding systemTtestfar-end IFU 4-8results form A-2fiber optic continuity 3-14–3-18results form A-2link performance 4-8results forms A-3setup 4-9near-end IFUresults form A-2power cable 3-7–3-8results form A-1setup 3-8power cable connection 2-4–2-5testingfiber optic cableprocedure 3-16, 3-21toolscommissioning 4-2site installation 3-2Wwall mount 3-3warningsrisk from fiber optics xviconvention xvrisk of electrical shock xviconvention xvrisk of radio frequency energy exposure xviconvention xv