Transtek Medical Electronics TMB1591BS Blood Pressure Monitor User Manual TMB 1591 FDA

Guangdong Transtek Medical Electronics Co.,Ltd Blood Pressure Monitor TMB 1591 FDA

Users Manual

User ManualBlood Pressure Monitor TMB-1591-BSTo use the monitor correctly and safely, please read the manual thoroughly.Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1591-BS.Please keep this manual well in order to reference in future.Arm Typeversion:1.0Guangdong Transtek Medical Electronics Co., Ltd.Zone B, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China  FCC ID:OU9TMB1591BS
Table of ContentsINTRODUCTION........................................................................................2General DescriptionSafety InformationIndications for UseContraindicationsMeasurement PrincipleLCD Display SignalMonitor Components BEFORE YOU START................................................................................8The Choice of Power SupplyInstalling and Replacing the BatteriesMEASUREMENT.......................................................................................9PairingTie the CuffStart the MeasurementINFORMATION FOR USER......................................................................14Tips for measurementMaintenancesABOUT BLOOD PRESSURE....................................................................16What are systolic pressure and diastolic pressure?What is the standard blood pressure classification?Irregular heartbeat detectorWhy does my blood pressure fluctuate throughout the day?Why do I get a different blood pressure at home compared to the hospital?Is the result the same if measuring on the right arm?TROUBLESHOOTING..............................................................................18SPECIFICATIONS.....................................................................................19AUTHORIZED COMPONENT ..................................................................20CONTACT INFORMATION........................................................................20FCC STATEMENT......................................................................................21COMPLIED STANDARDS LIST.................................................................22EMC GUIDANCE.......................................................................................23CATALOGUE CATALOGUE1
Thank you for selecting TRANSTEK arm type blood pressure monitor (TMB-1591-BS). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service.Readings taken by the TMB-1591-BS are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.This manual contains important safety and care information, and provides step by step instructions for using the product.Read the manual thoroughly before using the product.The signs below might be in the user manual, labeling or other component. They are the requirement of standard and using.Safety InformationFeatures:68mm*90mm Digital LCD display with White backlightMaximum 99 records Measuring during inflation technologyT1A/250V Φ3.6*10CCCF1For indoor use onlySymbol for “MANUFACTURER”Symbol for “SERIAL NUMBER”Symbol for “TYPE BF APPLIED PARTS”Symbol for “ENVIRONMENT PROTECTION – Electrical waste products should not be disposed of with household waste. Please followlocal guidelines.”Symbol for “DIRECT CURRENT”Symbol for “Class II Equipment”Symbol for “THE OPERATION GUIDE MUST BE READ”General DescriptionCaution: These notes must be observed to prevent any damage to the device.Indications for UseThe Transtek Blood Pressure Monitor is digital monitors intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from  22cm to 42cm(about 8¾˝-16½˝). It is intended for adult indoor use only.IP22The ingress protection: the device could protected against solid foreign objects of 12.5mm and greater, and against vertically falling water drops when ENCLOSURE tilted up to 15° SNCAUTION* Be careful to strangulation due to cables and hoses, particularly due to excessive length.* At least 30 min required for ME equipment to warm from the minimum storage temperature between uses until it is ready for intended use. At least 30 min required for ME equipment to cool from the maximum storage temperature between uses until it is ready for intended use.* This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS;* Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies can affect this equipment and should be kept at least a distance d away from the equipment. The distance d is calculated by the MANUFACTURER from the 80 MHz to 5.8 GHz column of Table 4 and Table 9 of IEC 60601-1-2:2014, as appropriate.* Please use ACCESSORIES and detachable partes specified/ authorised by MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the user/patients.* There is no luer lock connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel.* Please use the device under the environment which was provided in the user manual. Otherwise, the performance and lifetime of the device will be impacted and reduced.INTRODUCTION INTRODUCTION32Measurement Principle   This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the air pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate.1.The device is not suitable for use on may be pregnant women or pregnant women.2.The device is not suitable for use on patients with implanted,electrical devices,such as cardiac pacemakers, defibrillators.Contraindications
INTRODUCTIONCAUTION* This device is intended for adult use in homes only. * The device is not suitable for use on neonatal patients, pregnant women,patients with implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from illnesses.* The device is not suitable for measuring the blood pressure of children. Ask your doctor before using it on older children.* The device is not intended for patient transport outside a healthcare facility.* The device is not intended for public use.* This device is intended for no-invasive measuring and monitoring of arterial blood pressure.It is not intended for use on extremities other than the arm or for functions other than obtaining a blood pressure measurement.* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure.Do not begin or end medical treatment without asking a physician for treatment advice.* If you are taking medication,consult your physician to determine the most appropriate time to measure your blood pressure. Never change a prescribed medication without consulting your physician.* Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose of a medicine prescribed by a doctor. Consult your doctor if you have any question about your blood pressure.* When the device was used to measure patients who have common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, the best result may occur with deviation. Please consult your physician about the result.* Don't kink the connection tube during use, otherwise, the cuff pressure may continuously increase which can prevent blood flow and result in harmful injury to the PATIENT.* When using this device, please pay attention to the following situation which may interrupt blood flow and influence blood circulation of the patient, thus cause harmful injury to the patient: connection tubing kinking too frequent and consecutive multiple measurements; the application of the cuff and its pressurization on any arm where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present; inflating the cuff on the side of a mastectomy.* Warning: Do not apply the cuff over a wound;otherwise it can cause further injury.*Do not inflate the cuff on the same limb which other monitoring ME equipment is applied around simultaneously, because this could cause temporary loss of function of those simultaneously-used monitoring ME equipment.*On the rare occasion of a fault causing the cuff to remain fully inflated during measurement, open the cuff immediately. Prolonged high pressure (cuff pressure > 300mmHg or constant pressure > 15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis.*Please check that operation of the device does not result in prolonged impairment of patient blood circulation.* When measurement, please avoid compression or restriction of the connection tubing.* The device cannot be used with HF surgical equipment at the same time.* The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was clinically investigated according to the requirements of ISO 81060-2:2013.* To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the manufacturer.* This device is contraindicated for any female who may be suspected of, or is pregnant. Besides providing inaccurate readings, the effects of this device on the fetus are unknown.* Too frequent and consecutive measurements could cause disturbances in blood circulation and injuries.* This unit is not suitable for continuous monitoring during medical emergencies or operations.Otherwise, the patient’s arm and fingers will become anaesthetic, swollen and even purple due to a lack of blood.* When not in use, store the device with the adapter in a dry room and protect it against extreme moisture, heat, lint, dust and direct sunlight. Never place any heavy objects on the storage case.* This device may be used only for the purpose described in this booklet. The manufacturer cannot be held liable for damage caused by incorrect application.*This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in this booklet.CAUTION* The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide.* Warning: No servicing/maintenance while the ME equipment is in use.* The patient is an intended operator.* The patient can measure data and change batteries under normal circumstances and maintain the device and its accessories according to the user manual.* To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated interference signal or electrical fast transient/burst signal.* The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient environment. If you are allergic to polyester, nylon or plastic, please don't use this device. * During use, the patient will be in contact with the cuff. The materials of the cuff have been tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not cause any potential sensization or irritation reaction.* Adaptor is specified as a part of ME EQUIPMENT.* If you experience discomfort during a measurement, such as pain in the arm or other complaints, press the START/STOP button to release the air immediately from the cuff. Loosen the cuff and remove it from your arm.* If the cuff pressure reaches 40 kPa (300 mmHg), the unit will automatically deflate. Should the cuff not deflate when pressures reaches 40 kPa (300 mmHg), detach the cuff from the arm and press the START/STOP button to stop inflation.* Before use, make sure the device functions safely and is in proper working condition. Check the device, do not use the device if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.* Do not wash the cuff in a washing machine or dishwasher!* The service life of the cuff may vary by the frequency of washing, skin condition, and storage state. The typical service life is 10000 times.* It is recommended that the performance should be checked every 2 years and after maintenance and repair, by retesting at least the requirements in limits of the error of the cuff pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the local guidelines.* Manufacturer will make available on request circuit diagrams, component part lists, descriptions, calibration instructions,etc., to assist to service personnel in parts repair.* The plug/adapter plug pins insulates the device from the main supply. Do not position the device in a position where it is difficult to disconnect from the supply mains to safely terminate operation of ME equipment.* The operator shall not touch output of batteries /adapter and the patient simultaneously.* Cleaning :Dust environment may affect the performance of the unit. Please use the soft cloth to clean the whole unit before and after use. Don’t use any abrasive or volatile cleaners.* The device doesn’t need to be calibrated within two years of reliable service.* If you have any problems with this device, such as setting up, maintaining or using, please contact the SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself in the event of malfunctions. The device must only be serviced, repaired and opened by individuals at authorized sales/service centers.* Please report to Transtek if any unexpected operation or events occur.* Keep the unit out of reach of infants, young children or pets to avoid inhalation or swallowing of small parts. It is dangerous or even fatal.INTRODUCTION54
LCD Display SignalSYMBOL DESCRIPTIONSystolic blood pressure High pressure resultDiastolic blood pressure Low pressure resultEXPLANATIONPulse Pulse/minutemmHg Measurement Unit of the blood pressureBattery Indicator Indicate the current battery Irregular heartbeat detectionIrregular heartbeatGradeHeartbeat Heartbeat dectetion during measurementThe grade of the blood pressureComponent list of pressure measuring system1 Cuff 2 Air pipe3 PCBA4 Pump5 ValveMonitor ComponentsBATTERY COMPARTMENTON/STANDBY BUTTONLCD DISPLAY AIR HOSEAIR CONNECTOR PLUGCUFFList1. Blood Pressure Monitor    (TMB-1591-BS)4. User manual3. 4*AA alkaline batteries2. Cuff (about 22cm~42cm)    (Type BF applied part)5. AC adaptor (UE08WCP-060100SPA)Data transmission errorShocking reminder Shocking will result in inaccurateSYSmmHgPULSE  /MINmmHgDIAData transmission errorDC POWER SOCKETINTRODUCTION INTRODUCTION76
The Choice of Power SupplyIn order to get the best effect and protect your monitor,please use the right battery and special power adaptor. The power adapter is a part of the device. After using, please pull out the adaptor plug insulates  from the main supply. Do not position the device in a position where it is difficult to disconnect from the supply mains. 1.Slide off the battery cover.2.Install the batteries by matching the correct polarity, as shown.3.Replace the cover.1.Battery powered mode:    6VDC 4*AA alkaline batteries2.AC adaptor powered mode:    6V       1A(Can be supplied by AC adaptor model UE08WCP-060100SPA !)   Right picture is the hole in for power adaptor.Installing and Replacing the BatteriesCAUTIONRemove batteries if the device is not likely to be used for some time.The old batteries are harmful to the environment, do not dispose with other daily trash.Remove the old batteries from the device and follow your local recycling guidelines.CAUTIONReplace the batteries whenever the below happenThe showsThe display dimsThe display does not light upWhen the blood pressure monitor is off, press On/Standby button for 2 full seconds to enter bluetooth pairing mode. The symbol        flashes, indicating the pairing is proceeding.  Turn on Bluetooth and APP. Make sure both are ON when pairing is proceeding.Then please select the user ID you want to connect with your smartphone on the app to continute the pair-up.If succeed, symbol          will be shown. Then blood pressure monitor will turn off.If fail, symbol          will flash all the time until the blood pressure turns off. PairingBluetooth Module No.: AW51802RF Frequency Range: 2402 MHz to 2480 MHz Max Power: -0.43dbmSupply Voltage: 2V-3.6 VTransmitting Distance: 10 metersBEFORE YOU START MEASUREMENT98
Rest for 5 minutes before measuring.Wait at least 3 minutes between measurements. This allows your blood circulation to recover.For a meaningful comparison, try to measure under similar conditions. For example, take daily measurements at approximately the same time, on the same upper arm, or as directed by a physician.Tie the Cuff1.Tie the cuff on your upper arm, then position the tube off-center toward the inner side of arm in line with the little finger.2.The cuff should be snug but not too tight. You should be able to insert one finger between the cuff and your arm.3.Sit comfortably with your arm resting on a flat surface. 2~3cm4.Correct position:   - Bare your arm or wear tights only when starting measurement.   - Sit comfortably with legs uncrossed, feet flat on the floor, back and arm supported.   The center of the cuff should be at the same level as the right atrium of the heart.Start MeasurementWhen the blood pressure monitor is off, press On/Standby button to turn it on, it will finish the whole measurement.LCD display Adjust to zero.Inflating and Measuring Display and save the result.MEASUREMENT MEASUREMENT1110
The blood pressure monitor will proceed to data transmission after measurement. The bluetooth symbol flashes on the LCD indicates data is transmitting.Segments Pressure1 >= 02 >= 403 >= 804 >= 120Segments Pressure5 >= 1406 >= 1607 >= 1808 >= 200Notes: During inflation, the heart icon in the upper left blinks in accordance with the user’s pulse rate.Additionally, during inflation the progress metre to the right of the digits builds vertically up as the pressure increases according to the table below.After successful transfer, the device powers off the Bluetooth radio and the icon (and rectangle) are removed.If the user presses and releases the On/Standby button, another reading is initiated.If the user presses and holds the On/Standby button for 2 seconds, the device powers down.Or if there is no operation, after a 10 seconds of inactivity, the device powers down.During the measurement, if you press the On/Standby button to stop the measurement, the numerics are cleared.  It will display as below:If you press and release the On/Standby button, another reading is initiated.If you press and hold the On/Standby button for 2 seconds, the device powers down.Or if there is no operation, after a 10 seconds of inactivity, the device powers down.MEASUREMENTMEASUREMENT1312The most recent record (1) is shown first.  Each new measurement is assigned to the first (1) record. All other records are pushed back one digit (e.g., 2 becomes 3, and so on), and the oldest record (99) is dropped from the list.   CAUTION
Tips for Measurementwait at least 1 hour after dinner or drinkingWait at least 20 minutes after taking a bathIn a very cold environmentImmediate measurement after tea, coffee, smoking When talking or moving your fingersWhen you want to discharge urineMeasurements may be inaccurate if taken in the following circumstances.MaintenanceIn order to get the best performance, please follow the instructions below.Put in a dry place and avoid the sunshineAvoid intense shakingand collisionsUsing wet cloths to remove dirtAvoid touching water,clean it with a dry cloth in case.Avoid dusty and unstabletemperature environmentAvoid washing the cuffINFORMATION FOR USER INFORMATION FOR USER1514
What are systolic pressure and diastolic pressure? pressartery veinblood dischargingSystolicrelaxblood enteringDiastolic  Irregular Heartbeat DetectorCAUTIONWhy does my blood pressure fluctuate throughout the day?Is the result the same if measuring on the right arm?Why do I get a different blood pressure at home compared to the hospital?1. Individual blood pressure varies multiple times everyday. It is also affected by the way you tie your cuff and your measurement position, so please take the measurement under the same conditions.2.If the person takes medicine, the pressure will vary more.3.Wait at least 3 minutes for another measurement.The blood pressure is different even throughout the day due to weather, emotion, exercise etc, Also, there is the “white coat” effect, which means blood pressure usually increases in clinical settings.It is ok for both arms, but there will be some different results for different people. We suggest you measure the same arm every time.What you need to pay attention to when you measure your blood pressure at home: If the cuff is tied properly. If the cuff is too tight or too loose.If the cuff is tied on the upper arm.If you feel anxious.Taking 2-3 deep breaths before beginning will be better for measuring.        Advice: Relax yourself for 4-5 minutes until you calm down.When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement. Usually this is NOT a cause for concern. However, if the symbol appears often, we recommend you seek medical advice. Please note that the device does not replace a cardiac examination, but serves to detect pulse irregularities at an early stage.An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is measuringthe systolic and diastolic blood pressure.During each measurement, the monitor records all thepulse intervals and calculate the average ; if there are two or more pulse intervals ,the differencebetween each interval and the average is more than the average value of ±25% , or there are fouror more pulse intervals ,the difference between each interval and the average is more than theaverage value of ±15%,the irregular heartbeat symbol appears on the display when themeasurement results are appear.What is the standard blood pressure classification?The chart on the right is the standard blood pressure classifi-cation published by AmericanHeart Association (AHA).Please consult a physician if your measuring result falls outside the range. Please note that only a physician can tell whether your blood pressure value has reached a dangerous point.CAUTIONBlood Pressure CategoryNormalElevatedHigh Blood Pressure(Hypertension) Stage 1High Blood Pressure(Hypertension) Stage 2Hypertensive Crisis(Consult your doctor immediately)SystolicmmHg (upper#)DiastolicmmHg (lower#)less than 120120-129130-139140 or higherHigher than 180andororand/orless than 8080-8990 or higherHigher than 120This chart reflects blood pressure categories defined by American Heart Association.and less than 80ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE1716
    This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you think it should, check here before arranging for servicing.Power supplyBattery powered mode: 6VDC 4*AA alkaline batteriesAC adaptor powered mode:6V     1A(Can be supplied by AC adaptor model UE08WCP-060100SPA !)Display mode Digital  LCD  V.A.68mm*90mmMeasurement mode Oscillographic testing modeMeasurement rangeAccuracyNormal working conditionStorage & transportationconditionMeasurement perimeterof the upper arm About 22cm~42cmNet Weight Approx.300g(Excluding the dry cells)External dimensionsAttachmentApprox.92mm*140mm*46mm4*AA alkaline batteries,user manual,AC adapter  Mode of operation Continuous operationDegree of protectionSoftware VersionType BF applied partProtection against ingress of waterV01WARNING: No modification of this equipment is allowed.IP22Rated cuff pressure: 0mmHg~299mmHg(0kPa ~ 39.9kPa)Measurement pressure: SYS: 60mmHg~230mmHg (8.0kPa~30.7kPa) DIA: 40mmHg~130mmHg (5.3kPa~17.3kPa)Pulse value: (40-199)beat/minutePressure:5℃-40℃ within±3mmHgpulse value:±5%Temperature:-20°C to +60°CA relative humidity range of ≤ 93%, non-condensing, at a water vapour pressure up to 50hPaPROBLEM SYMPTOM CHECK THIS REMEDYNo powerLowbatteriesErrormessageDisplaywill not light up.Batteries are exhausted. Replace with new batteriesInsert the batteries correctlyReplace with new batteriesBatteries are insertedincorrectly.Batteries are low.showsUnsuccessful pairing.Check if both the APP and Bluetooth are on, operateand send the data again.E 1 shows The cuff is not secure.Readjust the cuff and relax for a momentand then measure again.AC adaptor is insertedincorrectly.Insert the AC adaptor tightlyThe display indicates the “BAT LO”message, pauses for 3 seconds.The battery icon shows empty (does not flash.)A temperature range of :+5°C to +40°CA relative humidity range of 15% to 90%, non-condensing, but not requiring a water vapour partial pressure greater than 50 hPaAn atmospheric pressure range of : 700 hPa to 1060 hPaWarningmessage “out ” shows Out of measurementrangeRelax for a moment.Refasten the cuff and thenmeasure again. If theproblem persists, contactyour physician.TROUBLESHOOTING SPECIFICATIONS1918
Authorized Component1.please use the TRANSTEK authorized adapter.Contact InformationAdapterInput:100~240V,50~60Hz,400mAOutput:6V      1AType: UE08WCP-060100SPA( Conforms to UL certificate )For more information about our products, please visit www.transtek.cn.you can get customer service, usual problems and customer download, transtek will serve you anytime.Manufactured by:Company:Address:Guangdong Transtek Medical Electronics Co., Ltd.Zone B, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China  Guangdong Transtek Medical Electronics Co., Ltd.FCC ID:OU9TMB1591BSThis device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation.Caution: The user is cautioned that changes or modifications notexpressly approved by the party responsible for compliance could voidthe user's authority to operate the equipment.NOTE: This equipment has been tested and found to comply with thelimits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference willnot occur in a particular installation.If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or moreof the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.FCC Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth foran uncontrolled environment.This transmitter must not be co-located or operating in conjunction withany other antenna or transmitter.FCC StatementFCC STATEMENTAUTHORIZED COMPONENT2120
Complied Standards ListEN ISO 14971:2012 / ISO 14971:2007 Medical devices - Application of risk management to medical devicesEN 1041:2008 Information supplied by the manufacturer of medical devicesEN 60601-1:2006+A1:2013/ IEC 60601-1:2005+A1:2012 Medical electrical equipment - Part 1: General requirements for basic safety and essential performanceEN 60601-1-11:2015/ IEC 60601-1-11:2015 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environmentEN 60601-1-2:2015/ IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and testsEN ISO 81060-1:2012 Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement typeEN 1060-3:1997+A2:2009 Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systemsEN 1060-4:2004 Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometersEN 60601-1-6:2010+A1:2015/IEC 60601-1-6:2010+A1:2013 Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: UsabilityIEC 62366-1:2015 Medical devices - Part 1: Application of usability engineering to medical devicesEN 62304:2006/AC: 2008 / IEC 62304: 2006+A1:2015   Medical device software - Software life-cycle processesRisk managementLabelingUser manualGeneral Requirements for SafetyElectromagneticcompatibilityPerformancerequirementsClinical investigationUsabilitySoftware life-cycle processesBio-compatibilityISO 10993-1:2009 Biological evaluation of medical devices- Part 1: Evaluation and testing within a risk management processISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicityISO 10993-10:2010 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitizationEN ISO 15223-1:2016 / ISO 15223-1:2016  Medical devices. Symbols to be used with medical device labels, labelling and information to be supplied. Part 1 : General requirementsIEC 80601-2-30:2009+A1:2013 Medical electrical equipment- Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometersISO 81060-2:2013  Non-invasive sphygmomanometers - Part 2: Clinical validation of automated measurement typeEMC Guidance1)This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided,and this unit can be affected by portable and mobile RF communications equipment.2)* Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.3)Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation!4)* Caution: This machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used.Table 1 Guidance and manufacturer’s declaration – electromagnetic emissionsRF emissions CISPR 11 Group 1 Class B Class ACompliesComplianceHarmonic emissions IEC 61000-3-2Voltage fluctuations/ flicker emissions  IEC 61000-3-3  RF emissions CISPR 11Emissions test Electromagnetic environment - guidanceThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.The device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.The device is suitable for use in all establishments,other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.EMC GUIDANCECOMPLIED STANDARDS LIST2322
 Guidance and manufacturer’s declaration – electromagnetic immunity Immunity test ±8 kV contact±15 kV air ±8 kV contact±15 kV air  ±2 kV power supply lines: line(s) to line(s): ±1 kV  line(s) to earth: ±2 kV 0%UT; 0.5 cycleAt 0°, 45°, 90°, 135°,180°,225°,270° and 315°0%UT ;  1 cycle and 70%UT ; 25/30 cyclesSingle phase: at 0°0% UT ; 300 cycle30 A/m50Hz/60HzNOTE      UT  is the a.c. mains voltage prior to application of the test level. Table 2 Compliance levelElectrostatic discharge (ESD) IEC 61000-4-2 Electromagnetic environment - guidance30 A/m50Hz/60HzPower frequency (50Hz/60Hz) magnetic field IEC 61000-4-8 Voltage dips, short interruptionsand voltagevariations on power supply input linesIEC 61000-4-11 Electrical fast transient/burst IEC 61000-4-4 SurgeIEC61000-4-5input/output lines:±1 kVThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.IEC 60601 test levelFloors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.±2 kV power supply lines: 100 kHz repetitionfrequencyline(s) to line(s): ±1 kV  100 kHz repetitionfrequencyMains power quality should be that of a typical commercial or hospital environment.Mains power quality should be that of a typical commercial or hospital environment.Mains power quality should be that of a typical commercial or hospital environment.Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.0% UT ; 0.5 cycleAt 0°, 45°, 90°, 135°,180°,225°,270° and 315°0% UT ;  1 cycle and 70% UT ; 25/30 cyclesSingle phase: at 0°0% UT ;300 cycleTable 3Guidance and manufacturer’s declaration – electromagnetic immunityImmunity test Compliance levelIEC 60601 Test levelConducted RFIEC 61000-4-6 Radiated RF IEC 61000-4-310V/m, 80% Amat 1kHz150 kHz to80 MHz: 3 Vrms6Vrms (in ISM and amateur radio bands)80% Am at 1kHz Electromagnetic environment - guidanceNOTE 1  At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.aField strengths from fixed transmitters, such as base stations for radio (cellular / cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the device.Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.bThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.150 kHz to80 MHz: 3 Vrms6Vrms (in ISM and amateur radio bands)80% Am at 1kHz Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation appropriate for the frequency of the transmitter.Recommended separation distances:d=0.35        ;d=1.210V/m, 80% Amat 1kHz80 MHz to 800 MHz:d=1.2800 MHz to 2.7 GHz:d=2.3where, P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer, d is the recommended separation distance in meters (m).  Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than the compliance level in each frequency range.Interference may occur in the vicinity of equipment marked with the followingsymbol:PPPPEMC GUIDANCE EMC GUIDANCE2524
 150 kHz to 80 MHz  80 MHz to 800 MHz  800 MHz to 2.7 GHz Table 4Recommended separation distances between portable and mobile RF communications equipment and the device.Rated maximum outputpower of transmitter(W) Separation distance according to frequency of transmitter (m)0.010.11101000.12 0.120.381.23.8120.230.732.37.323=d =d 1.2 2.3=d0.371.23.8123.5The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmittters) and the device as recommended below, according to the maximum output power of the communications equipment.For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1    At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2    These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.PPP Table 5Guidance and manufacturer’s declaration - electromagnetic immunityTest Frequency (MHz)385 0.3 27The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device, should assure that it is used in such an environment.NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3.Radiated RF IEC61000-4-3 (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Band a)(MHz)Service a) Modulation b) Modulation b)(W)Distance (m)IMMUNITY TEST LEVEL (V/m)380-390 TETRA 400Pulse modulation b) 18Hz1.8450 380-390GMRS 460,FRS 460FM c) ± 5kHzdeviation 1kHzsine20.3 28710 704-787745780LTE Band13,17Pulse modulation b)217Hz0.2 0.3 9810870930800-960GSM 800/900,TETRA 800,iDEN 820,CDMA 850,LTE Band 5Pulse modulation b)18Hz20.3 281720184519701700-1990GSM 1800;CDMA 1900;GSM 1900;DECT;LTE Band 1,3,4,25; UMTSPulse modulation b)217Hz20.3 2820.3 282450 2400-2570Bluetooth,WLAN,802.11 b/g/n, RFID2450, LTEBand 7Pulse modulation b)217 Hz5240524057855100-5800WLAN802.11a/nPulsemodulation b)217 Hz0.2 0.3 9a) For some services, only the uplink frequencies are included.b) The carrier shall be modulated using a 50% duty cycle square wave signal.c) As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case.The MANUFACTURER should consider reducing the minimum separation distance, based on RISK MANAGEMENT, and using higher IMMUNITY TEST LEVELS that are appropriate for the reduced minimum separation distance. Minimum separation distances for higher IMMUNITY TEST LEVELS shall be calculated using the following equation:                                                                E=Where P is the maximum power in W, d is the minimum separation distance in m, and E is the IMMUNITY TEST LEVEL in V/m.EMC GUIDANCE EMC GUIDANCE26 27