www.RoperMobile.com CMU056-A1 11Return To Table of ContentsPRODUCT SPECIFICATIONS (CONTINUED)ELECTRICAL & ENVIRONMENTAL REQUIREMENTS (Continued)Free Fall Drop Resistance (*):Meets  and  exceeds  IEC  68-2-32  method  1  (2 meter drop on concrete)Meets  and  exceeds  MIL-STD-810F  method 516.4 procedure IV<••Electrostatic Discharge:Meets EN 61000-4-2•Approvals CE Certication• FCC Class B•Warranty Manufacturer’s warranty: 1 year parts & labor Optional DAPCare Warranty extension availableRoper Mobile Technology reserves the right to change specications without notice.WARNING / CAUTION / NOTE DEFINITIONThe words WARNING, CAUTION, and NOTE carry special meanings and should be carefully reviewed.WARNINGAlerts the reader about a situation, which if not avoided, could affect the proper functioning of the unit and result in permanent damage to the unit.  CAUTIONAlerts the reader of a potentially hazardous situation, which if not avoided, may result in minor injury to the user or may cause damage to the equipment. This includes special care necessary for the safe and effective use of the device and the care necessary to avoid any damage that may occur as a result of use or misuse.Note:This provides special information to make important instructions clearer.Introduction
12 CMU056-A1 www.RoperMobile.comReturn To Table of ContentsSymbolsWarning, pay special attention.In  accordance  with  European  Directive  2002/96/EC  on  Waste  Electrical  and  Electronic Equipment (WEEE), this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately.  Refer to your local distributor for return and/or collection systems available in your country. Caution must be used when this symbol is present. This symbol indicates a danger for laser radiation.
www.RoperMobile.com CMU056-A1 13Return To Table of ContentsSafety PrecautionsWARNINGRefer to this Guide when inserting or removing batteries, cables or external peripherals.Operate  and  store  your  DAP  unit  within  the  temperature  limits  specied  in  this  Guide.Do not use any pointed objects on the keyboard, door or mechanisms. Doing so may damage the unit.Use  the  ‘Stylus’  which  has  been  provided    with  the  unit  by  Roper  Mobile  Technology,  as  it  has  been designed with a non-abrasive material that cannot scratch or damage the touch screen.Never expose the battery to extreme heat or dispose of by burning.Any attempts to open the case of a CE3240B unit will void the warranty.If  you  need  to  use  a  cable  other  than  the  ones  provided  or  recommended  by  Roper Mobile we recommend that you contact your Customer Service Representative nearest you. •••••••
14 CMU056-A1 www.RoperMobile.comReturn To Table of ContentsQuick TourFRONT VIEWOn/Off Key Light Sensor EndCap with aDAPtable Extension Color Screen Microphone Battery Status Indicator Cradle Communication Connector Head-Set Adapter Hand Strap Attachment Trigger Button (both sides) Function Key Navigation Key  (Left, Right, Top & Bottom)1.2.3.4.5.6.7.8.9.10.11.12.764235810911211
www.RoperMobile.com CMU056-A1 15Return To Table of ContentsQuick Tour2134BACK VIEWRelease screws for PC & SDIO Card Access Door Stylus (Pen) holder Trigger Buttons (Left & Right) Speaker Release screws to change eld replaceable battery (2 screws left and right).1.2.3.4.5.35
16 CMU056-A1 www.RoperMobile.comReturn To Table of ContentsGetting StartedBATTERY WARNINGSMain Batteries Very Low Following several hours of use or storage, the main battery will become very low and this warning will appear when there is still some power remaining. At  5%  the  battery  status  indicator  continues  to ash  and  a  window  will  display  to  indicate  to  the user that the battery is at a critical level and must be  re-charged.  This  warning  shall  be  displayed approximately  every  4  minutes  for  as  long  as  the battery is below 5 %.It is strongly recommended that the batteries be re-charged  immediately  to  avoid  loss  of  data.  Note: The level at which this warning is to appear can  be  congured  according  to  preference.  Refer to  “Battery  Power  Management”  for  further instructions.Main Battery Expired This  warning  will  appear  when  the  power  is  too low.Turn  the  unit  off  immediately  and  recharge  the batteries.WARNINGData may be lost if the unit is not re-charged immediately.  Backup Battery Low The backup battery will save programs and les in the memory for days.  The backup battery  is used when replacing the main battery or when the main battery has expired. The backup battery will be re-charged every time the main batteries are charged.  Note: The life of the backup battery will depend on:The residual power of the main battery.The amount of memory installed in the unit.••WARNINGUpon receiving your CE3000B unit, it is strongly recommended that you rst charge the batteries prior to use. These following messages are likely to appear due to the length of time the unit was stored. When the battery reaches the low level, the battery status indicator will ash red. The Main Battery eld will be highlighted as “Low” under the Battery or Status Tab. It will remain highlighted as long as the battery level is between 6% and 16%.
www.RoperMobile.com CMU056-A1 17Return To Table of ContentsGetting Started CHARGING THE BATTERYThe installation requires the Modular Charger CSCE300-NA (North America - 110V / 120V AC Adapter) or the CSCE300-EU (Europe 220V) or the CSCE300-UK (United Kingdom 220 V).          Insert modular charger into round connector (a) at the back of the cradle.  Connect the Modular Charger to the wall outlet.           Insert unit into cradle.Note: The CE3240B Battery Status indicator will turn red in the next 5 seconds indicating that charging is now in progress. The light will turn green when charging is complete. Charging may take up to 3 hours. If the unit was turned off, it should turn back on after a few seconds or after 2 to 3 minutes if the main battery charge has been very low for some time. Processing will resume exactly where it was interrupted once re-charging starts.1.2.3.4.••CSCE300-NA,  CSCE300-EU,CECE300-UK(a)
18 CMU056-A1 www.RoperMobile.comReturn To Table of ContentsGetting StartedBATTERY STATUS INDICATORColor DenitionRed Charger is connected and charging.Green  Battery is fully charged.Blinking Red Warning, low batteryYellow Charger detected, but the battery charger temperature is too high or too low to re-charge. Charge will start when temperature is adequate.No Light Power from the charger is not detected.
www.RoperMobile.com CMU056-A1 19Return To Table of ContentsOperation GuideTURNING THE UNIT ON & OFFOnce charging is complete, the unit will automatically turn itself off after approximately 3 minutes.Turn Unit OnTo  turn  on  the  CE3240B  Unit,  press  the  ON / OFF key for 2 seconds and release.Note: Should the unit not turn on, it could be because the battery is too low. Refer back to “Charging the Battery” Section for further instructions.Turning the Unit Off ManuallyThere are two ways to turn the unit off:Press on the Start button located at the bottom left corner of the screen and then select “Suspend”  or To manually turn off the CE3240B unit, press the Function Key followed by the ON / OFF Key.1.1.2.+