Teltronic U PTRUNK25RF450 RF Unit P25 Base Station Radio/Repeater User Manual Installation Manual

Teltronic S.A.U. RF Unit P25 Base Station Radio/Repeater Installation Manual

Contents

Installation Manual

 RF Unit USER AND INSTALLATION MANUAL  01.01.00/1 Rev.1 PRODUCT:  RF Unit CODE:  D168X01_DDS09 VERSION:  01  REVISION:  01  DATE:  09/10/08 CLASSIFICATION: General information   Internal document   DOCUMENT MAINTENANCE THIS DOCUMENT HAS 16 PAGES EDIT.  DATE  AUTHOR  DESCRIPTION 1.0  27/12/07  José Roman  RF Unit User and Installation Manual. 1.1  09/10/08  Javier Córdova  General revision.                                                      DOCUMENT APPROVAL ACTIVITY  NAME  DATE  SIGNATURE Prepared      Revised Project Manager      Approved R&D Director
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 2 of 16  01.01.00/1 Rev.1   Disclaimer  Although every reasonable effort has been made to ensure the accuracy of the information contained herein and any other referred document, this should not be construed as a commitment on the part of Teltronic S.A. Unipersonal, and the liability of Teltronic S.A. Unipersonal for any errors and omissions shall be limited to the correction  of  such  errors  and  omissions.  Teltronic  S.A.  Unipersonal  welcomes  any  comment  as  a  way  to improve any delivered documentation.  The information contained herein has  been prepared for the use of appropriately trained personnel, and it  is intended for the purpose of the agreement under which the information is submitted. Any party using or relying upon this information assumes full responsibility for such use and in no event shall Teltronic S.A. Unipersonal be liable to anyone for especial, collateral, incidental, or consequential damages in connection with or arising out of the use of this information.  The information or statements given in these documents regarding the suitability, capacity or performance of the  mentioned  hardware  or  software  products  cannot  be  considered  binding  but  shall  be  defined  in  the agreement made between Teltronic S.A. Unipersonal and the customer.  Teltronic S.A. Unipersonal reserves the right to revise these documents and to make changes to its content at any time, without prior notification.   Copyrights  No part of the information contained herein  and  the  other  referred  documents  may  be copied, distributed or transmitted by any means to any other party without prior written permission of Teltronic S.A. Unipersonal. The distribution of this document may be also covered by NDA (non-disclosure agreement) between Teltronic S.A. Unipersonal and the receiver.  Please also note that part of these contents even may be covered by patent rights.  This  document,  the  referred  documents  and  the  described  product  are  considered  protected  by  copyright according to the applicable laws.  Teltronic and the Teltronic logo are registered trademarks of Teltronic S.A. Unipersonal.  Copyright © Teltronic S.A. Unipersonal. All rights reserved.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 3 of 16  01.01.00/1 Rev.1  CONTENTS:    1. INTRODUCTION ......................................................................................................... 4 2. UNPACKING AND CHECKING .................................................................................. 5 3. PREVIOUS CONSIDERATIONS................................................................................. 5 4. INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY ............ 5 5. EQUIPMENT DESCRIPTION ...................................................................................... 7 5.1. FRONT VIEW ....................................................................................................... 7 5.2. REAR VIEW ......................................................................................................... 8 5.3. MODULES ............................................................................................................ 9 6. INSTALLATION GUIDE ............................................................................................ 12 6.1. LOCATION ......................................................................................................... 12 6.2. POWER SUPPLY CONNECTION ...................................................................... 12 6.3. ANTENNA CONNECTION ................................................................................. 13 6.4. SWITCHING ON THE RF UNIT .......................................................................... 13 7. CONFIGURATION .................................................................................................... 14 8. INCIDENTS ............................................................................................................... 14 8.1. ALARMS ............................................................................................................ 14
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 4 of 16  01.01.00/1 Rev.1 1.  INTRODUCTION  The  RF  Unit  is  the  RF  transceiver  of  Teltronic  P25  systems,  with  a  transmitter output  power  of  100W.  Therefore,  this  is  a  mandatory  module  in  the  infrastructure  P25 network.  It  is  manufactured following  a  robust  mechanical  modular  design which  allows simple and economic maintenance.  The RF Unit is available in the following frequency bands:  380 - 400 MHz  410 - 430 MHz  450 - 470 MHz  764 - 806 MHz  806 - 870 MHz  The modules that form the RF Unit are:    RPS (Repeater Power Supply P25)  RPA P25 (Repeater Power Amplifier P25)  RTX P25 (Repeater Transmitter P25)  RRX P25(Repeater Receiver P25)  BSYNC (RF Unit Synchronism) - OPTIONAL  RCPU P25(Repeater Control Processing Unit P25)  The  proper  operation  of  any  electronic  device  depends  on  its  correct  use.  It  is therefore recommended to follow the instructions in this manual.  !CAUTION: Switch the RF Unit off before inserting/removing any of its modules.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 5 of 16  01.01.00/1 Rev.1  2.  UNPACKING AND CHECKING  The following elements are supplied in the box:  RF Unit  50Ω / 20W load termination Power Supply Cable Maintenance Cable Two Ethernet Cables  The equipment is supplied with all the modules already assembled in the rack. The modules  in  the  basic  configuration  are:  Power  Supply  module  (RPS),  Power  Amplifier (RPA  P25),  Transmitter  (RTX  P25),  Receiver  (RRX  P25)  and  Control  (RCPU  P25). Synchronism module (BSYNC) is necessary for testing purposes.   IMPORTANT: if any of these elements is missing or damaged, contact your dealer and / or installer.    3.  PREVIOUS CONSIDERATIONS  This manual contains information on instructions for installation, maintenance and use. Read the following pages before using this equipment.  Do not switch on the RF Unit without having previously connected the TX antenna and the 50Ω load to the TNC connector. The equipment may be seriously damaged. It is important to use an antenna adjusted to the RF Unit transmitter frequency band.  INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY  The equipment has been designed to fulfil the applicable compliance regulations.  The equipment complies with Part 15 of the FCC Title 47 of the Code of Federal Regulations.  Operation is subject to the condition that this device does not cause harmful interference.  The  equipment  complies  with  the  applicable  Part  90  of  the  FCC  Title  47  of  the Code of Federal Regulations.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 6 of 16  01.01.00/1 Rev.1  In any case, take the following points into consideration:      Most electronic equipments are susceptible to electromagnetic interference if they  are  not  duly  protected.  If  the  RF  Unit  is  placed  near  unprotected electronic devices, they may malfunction.  The RF Unit must not transmit without its antenna connected or without the 50Ω load in the TNC connector.  When installing the antenna, follow the guidelines for exposure of the human body to high and low frequency electromagnetic fields. Follow the supplier’s / manufacturer’s instructions.  Burns may be suffered if the antenna connector output of the power module (RPA P25) is touched by bare skin when the RF Unit is transmitting with the antenna disconnected.  Take care when handling the RF Unit. It has sharp edges, which may cut if handled incorrectly.  Maintenance and repair of these repeaters must be  carried out by qualified personnel only.  Connect the RF Unit chassis to the earth intake in the cabinet where it is to be installed.  Switch off the RF Unit before inserting/removing any of its modules   !
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 7 of 16  01.01.00/1 Rev.1  5.  EQUIPMENT DESCRIPTION 5.1. FRONT VIEW               1.- RPS (Repeater Power Supply). 2.- RPA P25 (Repeater Power Amplifier). 3.- RTX P25 (Repeater Transmitter). 4.- RRX P25 (Repeater Receiver). 5.- BSYNC (RF Unit Synchronism) - OPTIONAL 6.- RCPU P25 (Repeater Control Processing Unit). 7.- Power Supply switch. 7 1  2  3  4  5  6
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 8 of 16  01.01.00/1 Rev.1   5.2. REAR VIEW                 8.- Power Supply Connector. 9.- TX Antenna Connector (type N). 10.- RF cables between RTX P25 and RPA P25. 11.- RX Antenna Connector (type BNC). 12.- RX Diversity Antenna Connector (not used). 13.- BSYNC Connectors (not used). 14.- Ethernet Connector “ETHERNET_A”. 15.- Ethernet Connector “ETHERNET_B”. 16.- Synchronism Output Connector “SYNC_OUT_2”. 17.- Synchronism Output Connector “SYNC_OUT_1”. 18.- Synchronism Input Connector “SYNC_IN_1”. 19.- Synchronism Input Connector “SYNC_IN_2”. 20.- Bus BSR maintenance connector. 21.- RCPU P25 maintenance connector (VT-100). 22.- RRX2 maintenance connector (Not used). 23.- RRX P25 maintenance connector (VT-100). 24.- RTX P25 maintenance connector (VT-100). 25.- 50Ω / 20W load termination (TNC connector). 24 23 22 21 20 19 18 17 16 15 14 9 10 11 12 13 8 25
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 9 of 16  01.01.00/1 Rev.1  5.3. MODULES  1.- RPS (REPEATER POWER SUPPLY)  LEDs to indicate module status.  LED  TYPE  NORMAL STATUS FUNCTIÓN SUPPLY  Green   On   There are 26.4V at the RPS input 26.4V  Green   On   There are 26.4V at the RPS output 13.2V  Green   On   There are 13.2V at the RPS output  Power Supply switch (Ref. 7): ON/OFF switch to connect to and disconnect from the RF Unit   2.- RPA P25 (REPEATER POWER AMPLIFIER)  LEDs to indicate module status.  LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green  On  Power supply correct TX POWER  Green   On  Module transmitting   3.- RTX P25 (REPEATER TRANSMITTER)  LEDs to indicate module status.  LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR Red  Off  Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BUS ERROR  Red  Off   Communication failure with the RCPU P25 module RPA ERROR  Red  Off  RPA P25 failure RPW ERROR Red  Off   Reflected power failure
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 10 of 16  01.01.00/1 Rev.1 4.- RRX P25 (REPEATER RECEIVER)  LEDs to indicate module status.  LED TYPE NORMAL STATUS FUNCTIÓN ON  Green  On  Power supply correct REF. ERROR  Red  Off   Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BUS ERROR  Red  Off   Communication  failure  with  the  RCPU P25 module   5.- SLOT OPTION: BSYNC (RF Unit SYNCHRONISM)  LEDs to indicate the status of option BSYNC.   LED TYPE NORMAL STATUS FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR  Red  Off   Failure in the 10 MHz reference WARM UP  Red  Off   Oscillator in warming up phase TIME GPS  Green   Flashing  There is NMEA signal from GPS PPS GPS  Green   Flashing  There is PPS signal from GPS TIME LOCAL  Green   Flashing  There is NMEA local signal (without GPS) PPS LOCAL  Green  Flashing  There is PPS local signal (without GPS)  NOTE: this slot is not used in the RF Unit basic configuration.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 11 of 16  01.01.00/1 Rev.1 6.- RCPU P25 (REPEATER CONTROL)  LEDs to indicate the module status.  LED TYPE NORMAL STATUS FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR  Red  Off  Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BUS ERROR  Red  Off   RF Unit bus failure DIV ERROR  Red  Off   Diversity failure LSC ERROR  Red  Off   Communication failure with the LSC AUX  Green   Off   Not used MCCH  Green  Off / On  Main carrier indicator RF RX  Green   Flickering  APCO P25 information received RF TX  Green  On   APCO P25 information transmission ETH LINK1  Yellow  On   Link between the local network switch and the RCPU P25 module in Ethernet port 1 ETH LINK2  Yellow  Off   Link between the local network switch and the RCPU P25 module in Ethernet port 1 ETH RX  Green   Flashing   Reception of an Ethernet packet ETH TX  Green   Flashing   Transmission of an Ethernet packet
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 12 of 16  01.01.00/1 Rev.1 6.  INSTALLATION GUIDE  The following recommendations must be followed closely before starting up the RF Unit module.  6.1. LOCATION  The RF Unit has been designed in the standard format of 19” / 3 units high and it must be installed in cabinets with this format.  The RF Unit site must be permanent, well-ventilated and without vibrations.  6.2. POWER SUPPLY CONNECTION  DC  power  supply:  check  that  the  power  supply  source  and/or  the  battery  to  be used meets the voltage and current requirements necessary to supply the equipment:   Nominal voltage: 26.4VDC (range: from 21.12 to 31.68 VDC).  Minimum source current: 20 A.  There is a 15 A internal fuse in the RPS module (Ref. 1 of RF Unit) to protect the equipment from over-voltage. There is a power control circuit  in the RPS P25 module in order to avoid an over-current condition.  If  lead  batteries  are  used,  they  are  to  be  placed  as  far  from  the  RF  Unit  as possible  to  prevent  corrosion  in  the  repeater  due  to  battery  vapours.  They should be situated in a well-ventilated place.  Use the power supply connector provided (D013000) to connect the RF Unit to the  power  supply  source.  Use  a  cable  with  2.5  mm2  minimum  diameter  (or AWG-12). Ensure that the connection is made with the correct polarity.  Ensure that the earth connection is made. Make this connection with a cable of maximum diameter and minimum length. NEVER use a gas or electricity conduit as an earth.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 13 of 16  01.01.00/1 Rev.1  6.3. ANTENNA CONNECTION   Choose  the  most  adaptable  antenna  for  the  installation.  The  antenna  must have  an  impedance  of  50  ohms  to  the  equipment  transmission  frequency. Install the antenna in accordance with the manufacturer’s instructions.  Use a coaxial cable, avoiding as much as possible large cable lengths. Cable impedance is 50 ohms.  Measure the ROE of the installation. Never accept a ROE greater than 2.  If  a  duplexer  module  or  a  band  pass  filter  is  required,  adjust  them  to  the working frequency before starting up.  6.4. SWITCHING ON THE RF Unit   Check the connections between the modules.  Check that the power supply source is connected correctly.  Check  that  the  RF  SMB  cables  are  connected  correctly  (see  Rear  View diagram Ref. 10).  Check the connections of the antennas in the RPA P25 and RRX P25 modules.  Check the 50Ω load is connected to the rear TNC connector in the RPA P25.  Check that the RPS P25 module LED SUPPLY is on.  Activate the power on switch on the RPS P25 module.  Check that the 26.4V LED and 13.2V LED on the RPS P25 module are on and check that the LEDS “ON” are switched on in the other modules.  Wait for the RF Unit to start up.  Note:  See  subclause  5.3  for  more  information  on  references  for  the  different modules and LEDs.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 14 of 16  01.01.00/1 Rev.1  7.  CONFIGURATION  A RF Unit is configured via an NMS (Network Management System). To configure the RF Unit, consult the NMS manual.   8.  INCIDENTS  The repeater must be repaired by authorized technical personnel only. If a RF Unit failure occurs, the entire RF Unit must be replaced. If transmitter module is  damaged  and  there  is  not  an  entire  RF  Unit  available  to  replace, set  RTX P25 and RPA P25 modules previously calibrated jointly. In last case and if is not possible to carry out one of  the two previous options, replace one of these two modules and make the gain calibration again.    If  an  error  or  alarm occurs in  the  RF  Unit,  this  is  indicated in  the  corresponding LED for each one of the modules. The following list shows the possible failures and their solutions.  8.1. ALARMS   Led indication Status  Failure / Solution RPS SUPPLY  OFF POWER SUPPLY FAILURE. CHECK THAT THE SOURCE AND THE POWER SUPPLY CABLE ARE CORRECTLY CONNECTED. CHECK THE INTERNAL FUSE OF THE RPS. CONTACT TECHNICAL SERVICES IF UNSOLVED.  26.4V  OFF  Power supply failure. Contact Technical services. 13.2V  OFF  Power supply failure. Contact Technical services.  RPA P25 ON  OFF POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES.  TX POWER  OFF No power transmission in the antenna. Wait for RF Unit to be started up. Check other LED indications. Contact Technical Services if unsolved.   !
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 15 of 16  01.01.00/1 Rev.1  RTX P25 ON  OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES.  REF. ERROR ON  Failure in the 10MHz reference. Contact Technical services.  INT. ERROR  ON  Internal failure. Contact Technical services.  BUS ERROR  ON Communication failure with the RCPU P25 module. Check that all the modules are correctly installed. Contact Technical services if still unsolved. RPA P25 ERROR  ON FAILURE IN THE RPA P25 MODULES. CHECK THAT THE RF SMB CABLES (REF. 10) ARE PROPERLY CONNECTED. CONTACT TECHNICAL SERVICES IF STILL UNSOLVED. RPW ERROR ON  Reflected power alarm. Check that the antenna is properly installed. Contact Technical services.  RRX P25 ON  OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES. REF. ERROR ON  Failure in the 10MHz reference. Contact Technical services. INT. ERROR  ON  Internal failure. Contact Technical services.  BUS ERROR  ON Communication failure with the RCPU P25 module. Check that all the modules are correctly installed. Contact Technical Services if still unsolved.  BSYNC ON  OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES. REF. ERROR ON  Failure in the 10MHz reference. Contact Technical services. TIME GPS  ON  If GPS is activated, there is failure in the data frame. Contact Technical Services. PPS GPS  OFF If GPS is activated, there is failure in the PPS signal of the GPS: - check that the starting up period has been exceeded (about 10 minutes after switching on) - check the GPS antenna connection. - check the correct positioning of the GPS antenna, in accordance with the manufacturer’s instructions. Contact technical services if still unsolved. TIME LOCAL  OFF  If GPS is not activated, there is failure in the local reference data frame. Contact Technical Services. PPS LOCAL  OFF  If GPS is not activated, there is failure in the local PPS signal. Contact Technical Services.
 RF Unit USER AND INSTALLATION MANUAL Code: D168X01_DDS09 Date: 09/10/08  Page: 16 of 16  01.01.00/1 Rev.1 RCPU ON  OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES. REF ERROR  ON Failure in the 10MHz reference. Check that the BSYNC module is installed or that the SYNC IN cable is correctly connected. Contact Technical services if still unsolved. INT ERROR  ON  Internal failure. Contact Technical Services. BUS ERROR  ON Communication failure by the RF Unit bus. Check that all the modules are correctly installed. Contact Technical services if still unsolved. DIV ERROR  ON Error in diversity: occurs when the difference in received power between received paths exceeds a level (20 dBs by default) for a consecutive number of receptions. These receptions on the received paths which do not have sufficient power are not counted. This alarm does not disappear until there are no receptions with the sufficient power, and until the difference of received power between received paths does not exceed the level previously mentioned. Check diversity configuration in the MSC.  Check that the reception antennas are correctly installed. Contact Technical services if still unsolved. LSC ERROR  ON Communication failure with the LSC. Check the Ethernet connections.  Check that the LSC is working correctly. Contact Technical Services if still unsolved. RF RX  Continuous ON Interference detection. Check the installation. Check that the work frequencies are correct. ETH LINK1  OFF  Failure in Ethernet link 1. Check Ethernet connection 1 and the Switch A. ETH LINK2  OFF  Failure in Ethernet link 2. Check Ethernet connection 2 and the Switch B. ETH RX  OFF  Packets are not received by Ethernet. Check the Ethernet connections. ETH TX  OFF  Packets are not sent by Ethernet. Check the Ethernet connections.