Televic NV CONFIDEAWCAP Wireless Conference System (Access Point) User Manual

Televic NV Wireless Conference System (Access Point)

User Manual

                           Confidea  Wireless Conference System Installation and User Manual
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 2
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 3  Table of Contents  Table of Contents ......................................................................................................................... 3 Section 1 – General Information ................................................................................................... 7 1. Copyright Statement ...................................................................................................... 9 2. Trademarks .................................................................................................................. 10 3. Safety Instructions ........................................................................................................ 11 3.1. FCC and ICES information .............................................................................................. 11 3.1.1.  Statements for FCC and Industry Canada .............................................................................. 11 3.2. Important safety instructions ........................................................................................ 12 3.3. Power Connections ....................................................................................................... 15 4. Confidea System Information ........................................................................................ 16 4.1. General  System Architecture ........................................................................................ 16 4.1.1.  Components .......................................................................................................................... 16 4.1.2.  Stand-alone system ............................................................................................................... 16 4.1.3.  Connected to Televic wired conference system ................................................................... 16 5. Wireless networks and frequency bands ....................................................................... 17 5.1. Wireless LAN ................................................................................................................ 17 5.2. Televic Confidea system ................................................................................................ 17 5.3. Frequency Planning ...................................................................................................... 18 5.3.1.  Use with WiFi base stations nearby ...................................................................................... 18 5.3.2.  Use of multiple Confidea systems ......................................................................................... 18 Section 2 – System Components .................................................................................................. 19 6. Confidea  wireless units ................................................................................................ 21 6.1. Introduction ................................................................................................................. 21 6.2. Controls and indicators ................................................................................................. 21 6.3. Installation ................................................................................................................... 23 6.4. Storage ......................................................................................................................... 23
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 4 6.5. Maintenance ................................................................................................................ 23 6.5.1.  General .................................................................................................................................. 23 6.5.2.  Cleaning ................................................................................................................................. 23 7. Microphones ................................................................................................................ 24 7.1. Introduction ................................................................................................................. 24 7.2. Electrical and  acoustic properties ................................................................................. 24 7.3. Microphone connector ................................................................................................. 24 7.4. Operation ..................................................................................................................... 25 7.5. Installation  and handling .............................................................................................. 25 8. Battery Pack ................................................................................................................. 26 8.1. Introduction ................................................................................................................. 26 8.2. Safety ........................................................................................................................... 26 8.3. Controls and indicators. ................................................................................................ 27 8.4. Installation ................................................................................................................... 27 9. Wall plug battery charger.............................................................................................. 28 9.1. Introduction ................................................................................................................. 28 9.2. Installation ................................................................................................................... 28 9.3. Charging a battery pack ................................................................................................ 29 10. Wireless Conference Access Point (WCAP) ..................................................................... 30 10.1. Introduction ................................................................................................................. 30 10.2. Installation ................................................................................................................... 30 10.2.1.  General .................................................................................................................................. 30 10.2.2.  Wall Mounting ....................................................................................................................... 30 10.2.3.  Table or Ceiling  Mounting .................................................................................................... 30 10.2.4.  Tripod Mounting .................................................................................................................... 31 10.2.5.  Antennas................................................................................................................................ 31 10.3. Connections and Controls ............................................................................................. 31 Section 3 – System  Configuration ................................................................................................ 33 11. Accessing the built-in web server .................................................................................. 35 11.1. Introduction ................................................................................................................. 35 11.2. First time access ........................................................................................................... 35 11.2.1.  Step 1 – Reset ........................................................................................................................ 35 11.2.2.  Step 2 – PC or MAC TCP/IP setup .......................................................................................... 36
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 5 11.2.3.  Step 3 – Cable Setup .............................................................................................................. 38 11.2.4.  Step 4 – Accessing WCAP ...................................................................................................... 38 11.2.5.  Step 5 – Default Screen ......................................................................................................... 38 11.3. Setting the IP address ................................................................................................... 39 12. Web server ................................................................................................................... 40 12.1. Setup ........................................................................................................................... 40 12.1.1.  Summary................................................................................................................................ 40 12.1.2.  TCP/IP settings ....................................................................................................................... 40 12.1.3.  Admin .................................................................................................................................... 41 12.2. RF Configuration ........................................................................................................... 42 12.2.1.  General .................................................................................................................................. 42 12.2.2.  Quality 2.4 GHz ISM ............................................................................................................... 42 12.2.3.  Quality 5.15 –  5.35 GHz ........................................................................................................ 42 12.2.4.  Quality 5.47 – 5.725 GHz ....................................................................................................... 42 12.2.5.  Quality 5.8 GHz ISM ............................................................................................................... 43 12.3. Conference Management .............................................................................................. 44 12.3.1.  General .................................................................................................................................. 44 12.3.2.  Unit Monitoring ..................................................................................................................... 46 12.3.3.  Init Units ................................................................................................................................ 46 12.4. Service ......................................................................................................................... 47 12.4.1.  Logging .................................................................................................................................. 47 12.4.2.  Update ................................................................................................................................... 47 12.5. Encryption .................................................................................................................... 47 12.5.1.  Key Assignment ..................................................................................................................... 47 13. Initialization ................................................................................................................. 49 13.1. Introduction ................................................................................................................. 49 13.2. Stand-alone mode ........................................................................................................ 49 13.2.1.  Access modes ........................................................................................................................ 49 13.2.2.  Selecting the Access Mode .................................................................................................... 49 13.2.3.  Unit initialization in ‘Open Access’ mode .............................................................................. 50 13.2.4.  Unit initialization in ‘Controlled Access’ mode ..................................................................... 50 13.2.5.  Adding a new unit in ‘Open Access’ mode ............................................................................ 51 13.2.6.  Adding a new unit in ‘Controlled Access’ mode .................................................................... 51 13.2.7.  Reviewing Init information .................................................................................................... 52 13.3. Coupled mode .............................................................................................................. 52 14. Encryption .................................................................................................................... 53
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 6 14.1. Introduction ................................................................................................................. 53 14.2. Default encryption ........................................................................................................ 53 14.3. Setting the default encryption ....................................................................................... 53 14.4. Custom encryption ....................................................................................................... 54 14.5. Setting a customized encryption ................................................................................... 54 14.6. Adding a unit with a customized encryption .................................................................. 56 14.7. Using multiple customized keys .................................................................................... 56 Section 4 – Use Cases .................................................................................................................. 57 15. Stand alone system ....................................................................................................... 59 15.1. Basic discussion ............................................................................................................ 59 15.2. Basic voting and opinion polling .................................................................................... 60 16. Connected to CE2500 or CPU5500 ................................................................................. 62 16.1. Discussion .................................................................................................................... 63 16.2. Advanced Voting .......................................................................................................... 65 16.3. Interpretation ............................................................................................................... 65 Section 5 – Appendix ................................................................................................................... 67
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 7     Section 1 – General Information
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 9 1. Copyright Statement No part of this publication or documentation accompanying this Product may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without the prior written permission of the publisher, except in case of brief quotations embodied in critical articles or reviews. Contents are subject to change without prior notice.  Copyright© 2008 by Televic NV. All rights reserved. The authors of this manual have made every effort in the preparation of this book to ensure the accuracy of the information. However, the information in this manual is supplied without warranty, either express or implied. Neither the authors, Televic NV, nor its dealers or distributors will be held liable for any damages caused or alleged to be caused either directly or indirectly by this book.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 10 2. Trademarks All terms mentioned in this manual that are known to be trademarks or service marks have been appropriately capitalized. Televic NV cannot attest to the accuracy of this information. Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 11 3. Safety Instructions The Confidea Wireless Conference system is state of the art and has been designed to meet quality. Nevertheless, the individual components of the conference system can cause danger for persons and material assets if  the conference system is not used as intended,  the conference system is set up by personnel not familiar with the safety regulations,  the conference system is converted or altered incorrectly,  the safety instructions are not observed. 3.1. FCC and ICES information (U.S.A and Canadian Models only) 3.1.1.  Statements for FCC and Industry Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  The Confidea equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  This Wireless discussion units and the Wireless Access Point comply with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and  2. this device must accept any interference received, including interference that may cause undesired operation.      Warning:  Changes or modifications made to this equipment not expressly approved by Televic NV may void the FCC authorization to operate this equipment.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 12   3.2. Important safety instructions 1. Read Instructions All the safety and operating instructions should be read before the product is operated. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Heed Warnings All warnings on the product and the operating instructions should be adhered to. 4. Follow Instructions All instructions for installation or operating / use should be followed. 5. Cleaning Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.  6. Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer's instructions have been adhered to. 7. Heat The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat. 8. Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards. 9. Water and Moisture Do not use this product near water or in a moistures environment - for example, near a bath tub, wash bowl, kitchen sink, or laundry tub; in a wet basement; or near a swimming pool, in an unprotected outdoor installation; and the like. 10. Accessories Only use attachments/accessories specified by the manufacturer. Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer.   Radiofrequency radiation exposure Information: This Wireless discussion units and the Wireless Access Point comply with FCC radiation exposure limits set forth for an uncontrolled environment. This Wireless discussion units and the Wireless Access Point should be installed and operated with minimum distance of 20 cm between the radiator and your body. The RF-parts of the Wireless discussion units and the Wireless Access Point must not be co-located or operating in conjunction with any other antenna or transmitter.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 13 11. Moving A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn. 12. Power Sources This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions. 13. Power Lines  An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching such power lines or circuits, as contact with them might be fatal. U.S.A. models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems. 14. Grounding or Polarization Do not defeat the safety purpose of the polarized or ground-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 15. Power-Cord Protection Power-supply cords should be routed to that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plug, convenience receptacles, and the point where they exit from the product. 16. Lightning For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and power-line surges. Not applicable when special functions are to be maintained, such as evacuation systems 17. Overloading Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock. 18. Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product. 19. Inflammable and Explosive Substance Avoid using this product where there are gases, and also where there are inflammable and explosive substances in the immediate vicinity. 20. Heavy Shock or Vibration When carrying this product around, do not subject the product to heavy shock or vibration. 21. Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 14 22. Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power-supply cord or plug is damaged. b. if liquid has been spilled, or objects have fallen into the product. c. If the product has been exposed to rain or water. d. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation. e. If the product has been dropped or damaged in any way. f. When the product exhibits a distinct change in performance-this indicates a need for service. 23. Replacement Parts When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. 24. Safety Check Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition. 25. Coax Grounding  If an outside cable system is connected to the apparatus, be sure the cable system is grounded. U.S.A. models only: Section 810 of the National Electrical Code, ANSI/NFPA No.70-1981, provides information with respect to proper grounding of the mount and supporting structure, grounding of the coax to a discharge apparatus, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 15 3.3. Power Connections For permanently connected equipment, a readily accessible disconnect device shall be incorporated in the fixed wiring; For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. TODO LABEL IN COLOR  This label may appear on the bottom of the apparatus due to space limitations. The lightning flash with an arrowhead symbol, with an equilateral triangle, is intended to alert the user to the presence of un-insulated ‘dangerous voltage’ within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.            Attention:  Equipment with or without ON/OFF switches have power supplied to the equipment whenever the power cord is inserted into the power source; however, the equipment is operational only when the ON/OFF switch is in the ON position. The power cord is the main power disconnect for all equipment.   Attention:  Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes.   Warning:  To prevent electric shock, do not use this (polarized) plug with an extension cord receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.   Warning:  To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not open the cabinet; refer servicing to qualified personnel only.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 16 4. Confidea System Information 4.1. General  System Architecture 4.1.1. Components Confidea is a wireless conference system offering conferencing facilities over a robust wireless link. Depending on the model, these facilities include discussion, voting and/or language distribution. The delegate units are stand-alone, table top units that wirelessly connect to the Confidea Wireless Conferencing Access Point (WCAP). This Access Point has a built-in web server that allows configuring and monitoring of the system from any PC or laptop with a network card, using a standard internet browser.  Depending on the application, Confidea can work as a standalone system, but can also be connected to an existing Televic TCS2500 or TCS5500 system. 4.1.2. Stand-alone system A stand-alone Confidea system offers basic discussion and basic voting or opinion polling (depending on the model) In this case there are no connections to other systems, except for the Confidea WCAP that can be connected to a LAN network for monitoring and configuring. The Confidea access point (WCAP) will in this set-up act as a mini central unit, offering all functionality for a basic discussion and/or opinion polling application. 4.1.3. Connected to Televic wired conference system As part of a wired system, the Confidea offers full functionality such as extended voting facilities and language distribution. When connected to a TCS2500 or TCS9000 central unit, the Confidea set-up becomes an integral part of the wired system
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 17 5. Wireless networks and frequency bands 5.1. Wireless LAN Most of the wireless local area computer networks today are based on the IEEE 802.11 a/b/g standards.  These standards were developed by the IEEE (Institute of Electrical and Electronics Engineers) in order to insure inter-operability between different WLAN vendors.  Refer to Table 5.1: Wireless LAN standardsTable 5.1 for an overview of the different standards:  Table 5.1: Wireless LAN standards 802.11 Standard Release Date Frequency (GHz) Maximum bit rate (Mbits/sec) Modulation type a 1999 5 54 OFDM b 1999 2.4 11 DSSS g 2003 2.4 54 OFDM    5.2. Televic Confidea system The wireless network of the Televic Confidea system is based on the 802.11 a/g standards.  Additional protocols have been added on top of the 802.11 a/g standards to provide high robustness against interference from other wireless devices. These additional protocols also ensure a guaranteed quality of service for the audio streams on the wireless network.  The Confidea system supports the following frequency bands (refer to Table 5.2): Table 5.2: Frequency bands supported by Confidea ISM 2.4 GHz RLAN low RLAN high ISM 5 GHz 2412 MHz 5180 MHz 5500 MHz 5745 MHz 2417 MHz 5200 MHz 5520 MHz 5765 MHz 2422 MHz 5220 MHz 5540 MHz 5785 MHz 2427 MHz 5240 MHz 5560 MHz 5805 MHz 2432 MHz 5260 MHz 5580 MHz   2437 MHz 5280 MHz 5600 MHz   2442 MHz 5300 MHz 5640 MHz   2447 MHz 5320 MHz 5660 MHz   2452 MHz   5680 MHz   2457 MHz   5700 MHz   2462 MHz       2467MHz       2472 MHz        In the 2.4 GHz ISM (Industrial Scientific Medical) band, there are 13 overlapping wireless carriers available. Only 3 non-overlapping carriers are available. In the “RLAN low” frequency band, there are 8 non-overlapping wireless carriers. In Europe all of these wireless carriers can be used. In the USA and Canada (FCC regulations) only the 4 lowest wireless carriers Note:  The 2.4GHz and 5GHz frequency bands are license free world wide. However you must be aware of country specific limitations and follow them.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 18 may be used (5180 MHz – 5200 MHz – 5220MHz – 5240MHz). In the “RLAN high” frequency band, there are 10 non-overlapping carriers. In Europe all of these wireless carriers can be used. In the USA and Canada (FCC regulations) these frequencies cannot be used. In the 5 GHz ISM frequency band, there are 4 non-overlapping carriers. All of these carriers can be used.  5.3. Frequency Planning 5.3.1. Use with WiFi base stations nearby When the CONFIDEA system is set to automatically select the wireless carrier frequency, the COFIDEA carrier frequency will be dynamically set to another channel if other existing WiFi wireless devices occupy the same channel.  This dynamic frequency allocation ensures a high robustness of the system even if the frequency occupation changes during the meeting. When the CONFIDEA system is set to manually select the wireless carrier frequency, then you must make sure the CONFIDEA wireless carrier does not overlap the already occupied WiFi wireless carrier channels.  5.3.2. Use of multiple Confidea systems When the CONFIDEA system is set to automatically select the wireless carrier frequency, the COFIDEA carrier frequency will be dynamically set to another channel if another CONFIDEA wireless system occupies the same channel.  This dynamic frequency allocation ensures that each CONFIDEA system will be set automatically to different frequencies. When the CONFIDEA system is set to manually select the wireless carrier frequency, you must make sure the CONFIDEA wireless carriers of the different rooms do not overlap each other.    Note:  When manually setting the  CONFIDEA wireless carrier, make sure to avoid channels already occupied by Wireless LANs or other Confidea systems in the area. Note:  When manually setting the  CONFIDEA wireless carrier, make sure to avoid channels already occupied by Wireless LANs or other Confidea systems in the area. Note:  The user can choose to set the wireless carriers manually or let the CONFIDEA system automatically select the best wireless carrier frequency.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 19     Section 2 – System Components
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 21 6. Confidea  wireless units 6.1. Introduction The wireless Confidea units consist out of Delegate and Chairman units.  Both are used as speech enforcement in a conference meeting.  The chairman units are in addition used to guide and control an ongoing discussion. All units can be divided into three categories:  Discussion : Confidea DD, CD (Figure 6.1 and Figure 6.4)  Voting : Confidea DV, CV (Figure 6.2 and Figure 6.5)  Interpretation : Confidea DIV, CIV (Figure 6.3 and Figure 6.6) 6.2. Controls and indicators The Confidea wireless units contain: 1. Microphone connector:  Connection of a microphone to the wireless unit. (see “reference to chapter microphone”) 2. Microphone button:  Activation/deactivation of the microphone.  Indication LEDs show the status of the microphone. (red : active, green : request) 3. Loudspeaker:  Distributes audio of the floor.  Mutes in case microphone is active. 4. Headphone connector:  Connection of headphone to the wireless unit. (see “reference to figure jack) 5. Volume buttons:  Change the volume level of the headphones. 6. Voting buttons:  Each voting button has a blue indication LED. 7. Information display:  Indication of voting, volume and channel information. 8. Channel selection buttons:  Changes the audio channel sent to the headphones.  Each button has a blue indication LED.  Pressing these buttons affects the information display. 9. Voting control buttons:  Use by a chairman to control a voting session. (start / pause / stop) 10. PRIOR button:  Short press : temporarily deactivate microphone of all active units. Long press : permanently deactivates microphone of all active units. 11. Next button:  Grants the floor to the next delegate in the waiting list. 12. RF Status LEDs:  Blue LED Indication of the condition of the RF connection. Off    :  connection established Blinking  :  searching connection On    :  out of range   13. Battery status LEDs : Red LED blinking the remaining operation time 1 Hz   :  4h remaining 2Hz   :  2h remaining 4Hz   :  1h remaining 14. Battery connector : (see battery pack – connectors and indicators) Note:  Units with the out of range LED on will be switched of after 2 minutes.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 22 Figure 6.1: Confidea DD   Figure 6.2: Confidea DV   Figure 6.3: Confidea DIV  Figure 6.4: Confidea CD    Figure 6.5: Confidea CV   Figure 6.6: Confidea CIV
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 23 6.3. Installation In order to use the wireless units the battery and microphone need to be installed. For instructions see install the microphone and install the battery. 6.4. Storage Disconnect the battery to avoid unwanted operation of the unit, causing discharge of the battery. Keep the devices in a clean and dry area. 6.5. Maintenance 6.5.1. General    6.5.2. Cleaning  To keep its original condition it is advised to periodically clean the unit. 15. Remove the battery out of the unit. 16. Use a clean soft cloth that is not fully moist. 17. Make sure the device is fully dry before usage.     Caution:  Do not use alcohol, ammonia or petroleum solvents or abrasive cleaners to clean the units. Caution:  Make sure the units are not exposed to excessive dust, humidity, mechanical vibration or shock. Caution:  Do not install the units in a location near heat sources as radiators, air ducts. or direct sunlight. Caution:  Do not put any objects on top of the units.  Object falling through the holes of the unit can cause damage.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 24 7. Microphones 7.1. Introduction The CONFIDEA-MICL and CONFIDEA-MICS pluggable microphones are used with the different delegate- and chairman units.  These microphones have a uni-directional response for optimum performance even in noisy conditions.  Both types have a very low susceptibility to interference from mobile phones. 7.2. Electrical and  acoustic properties Table 7.1: Microphone characteristics Transducer type Back electret (condenser) Operating principle Pressure gradient Polar pattern Uni-directional,  Super-cardioïd Frequency response 50 Hz – 16000 Hz Nominal impedance 1kOhm (at 1 kHz, drop resistance = 1k2, Vdd = 3.3VDC ) Load impedance > 5kOhm Max.SPL at 1 kHz 120 dB SPL Equivalent sound pressure level < 25 dB(A) Free field sensitivity 7mV/Pa, +/- 3 dB at 1 kHz  or  (-43dB, 0dB=1V/Pa at 1kHz) Power supply 3.3V DC, 0.5 mA Consumption 0.5 mA (without LED ring);  max. 25 mA (with illuminated ring)  7.3. Microphone connector Figure 7.1: Connector pin layout (bottom view)   pin 1 : microphone GND  pin 2 : microphone signal  pin 3 : unused  pin 4 : LED +  pin 5 : LED -
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 25 7.4. Operation The microphone contains following elements (refer to Figure 7.2): 1. Indicator ring: shows the status of the microphone 2. Union nut: attaches the pluggable microphone to the unit 3. Microphone plug: connects the microphone to the unit Figure 7.2: Microphone   The color of the microphone ring shows the status of the microphone (refer to Table 7.2: LED ring status). Table 7.2: LED ring status Color Condition Red (on) Microphone active Red (flash) Last minute of speech time (if set via software) or Speech request (if set via software)  7.5. Installation  and handling The pluggable microphone has a screw connection. For mounting, plug and fasten the microphone into the unit.          Caution:  Do not force the microphone thread wire while mounting the microphone on the unit. This can cause permanent damage to the microphone and receptacle connector on the delegate unit. 2 1 3
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 26 8. Battery Pack 8.1. Introduction The Confidea  battery  pack  is  used  with  the  wireless conference  units.  Refer  to  Table  8.1  for  the  list  of compatible devices. Table 8.1: Compatible devices Type Art-nr Description Confidea DD 71.80.9111 Delegate Unit Confidea CD 71.80.9112 Chairman Unit Confidea DV 71.80.9113 Delegate Unit Confidea CV 71.80.9114 Chairman Unit Confidea DIV 71.80.9115 Delegate Unit Confidea CIV 71.80.9116 Chairman Unit  Table 8.2: Characteristics Output voltage: 7.4V Capacity: 6600 mAh Charge time: 4 Hours Max charge voltage: 18V Autonomy: + 20 Hours (Typical) Dimensions(mm): 172 x 24 x 78  8.2. Safety Figure 8.1: Battery label 1  Figure 8.2: Battery label 2     Caution:  To avoid damage, use only the charger supplied by Televic to charge the Confidea Battery Packs.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 27 8.3. Controls and indicators. The battery pack (refer to Figure 8.3) contains: 1. Test button: Push to check the capacity and the status of the battery pack.  2. Capacity and status indicator:  Shows the capacity of the battery pack  (refer to Table 8.3) and the status of the charge circuitry (refer to Table 8.4). 3. Clip:  Locks the battery pack in the wireless unit. 4. Power LED Indicates the charger is connected and powered. 5. Charging LED: Indicates the status of the charge (in progress or completed) when the wall plug battery charger is connected. 6. Socket To connect the charger plug Figure 8.3: Confidea battery pack  8.4. Installation Install a charged battery pack in a compatible device (refer to Table 8.1). To  check  the  charge  of  the  battery  pack,  push  the test button 1 (refer to Figure 8.3). The  indicator  is  a  five  segment  LED.  The  first  LED (LED1 closest to the test button) is red and indicates a  low  capacity  battery.  The  higher  the  charge,  the higher the number of LEDs that light up. Table 8.3: Capacity Indicators LED on Remaining charge LED 1 (red) 0-20% (<4hours) LED 2 (orange) 20-40% (4-8 hours) LED 3 (orange) 40-60% (8-12 hours) LED 4 (green) 60-80% (12-16 hours) LED 5 (green) 80-100% (16-20 hours)   After  the  display  of  the  battery  condition  (for  4-5 seconds),  the  first  three  LEDs  (LED1  to  LED3)  will indicate  the  status  of  the  charge  circuitry  (refer  to Table 8.4). Table 8.4: Charge circuitry status LED 3 is flashing: Charging circuitry is ok All other indications: Indicates a failure Disconnect the charger from the battery pack and remove the battery pack from the conference unit.  To  charge  a  battery  pack,  refer  to  chapter  9.3 ‘Charging a battery pack’. Note:  The battery capacity as listed in Table 8.3 has an accuracy of 20%.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 28 9. Wall plug battery charger 9.1. Introduction Use the supplied wall plug battery charger to charge the battery pack used with wireless conference units. Refer to Table 9.2 for the compatible battery packs. Table 9.1: Electrical properties Input: 90-264V(AC)    50-60Hz Output: 15V(DC), 2A     Table 9.2: Compatible battery packs Type Art-nr Description Confidea BP 71.80.9121 Rechargeable Lithium-ion battery pack.  9.2. Installation Installing the plug of your need can be done by simply sliding one of the interchangeable plugs on the battery charger. (refer to Figure 9.1) Figure 9.1:Wall plug battery pack    Caution:  To avoid damage, use only the charger delivered by Televic to charge the Confidea Battery Packs.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 29 9.3. Charging a battery pack Connect the wall plug charger to the socket (6) of the battery pack (refer to Figure 8.3). The Power LED lights up (refer to Table 9.3).  During the charge, the charge LED is lit, and the capacity indicator shows the capacity of the battery pack. The top LED segment of the capacity indicator flashes (e.g.: if state of charge = 36% then LED2 will blink). Pushing the test button has no effect when the charge is in progress. When the charge is completed, the charging LED (5) and the capacity indicator (2) switch off. Push the test button (1) to check again the capacity of the battery pack. The LED segment indicator will show the capacity of the battery for a few seconds, then the status of the battery (refer to chapter 8.4 ‘Installation’).   Table 9.3: Charging status indicators Status Power  LED (green) Charging LED (yellow) Capacity indicator Charge is in progress On On On (top LED segment flashes) Charge is completed On Off Off (Push test button to check the capacity and the status) Charger is disconnected or not powered Off Off Off  (Push test button to check the capacity and the status)        Note: The wall plug charger can be used to power a Confidea wireless unit. In this case the battery pack needs to be installed in the unit.  Note: A battery pack can be charged separately, or when inserted in a wireless unit.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 30 10. Wireless Conference Access Point (WCAP) 10.1. Introduction All communication to and from the wireless units is controlled by the WCAP. 10.2. Installation 10.2.1. General     10.2.2. Wall Mounting The WCAP can be mounted on the wall by means of the 2 fixing holes at the bottom side of the device  Figure 10.1: Wall mounting  10.2.3. Table or Ceiling  Mounting The WCAP can simply be put on a flat surface or attached to a ceiling, using a bracket or the 2 fixing holes at the bottom side of the device.  Figure 10.2: Table or ceiling mounting    Caution:  Do not open the wireless access point. Opening the wireless access point may cause permanent damage to the device.   Opening WCAP is only allowed by qualified personnel.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 31 10.2.4. Tripod Mounting The WCAP can also be mounted on a tripod. Figure 10.3: Tripod mounting   10.2.5. Antennas The WCAP has 3 antennas which can be positioned in different directions independent from each other.  10.4: Antenna mounting  10.3. Connections and Controls Figure 10.5: WCAP connections   1. Power Switch The WCAP can be switched off with the power switch at the back of the WCAP. 2. Power Supply The power supply of the wireless delegate and interpreter units is provided by batterypacks (see also chapter 2.3) The power supply of the WCAP is provided by a 220VAC/24VDC adaptor The WCAP can also be powered like a SDC8200 or TCS2500 wired delegate unit (48VDC) or by connecting it to a SPL5000 ; in both case no seperate power supply is needed . (see also Chapter 4) 3. Digital Bus Connection Digital Bus connection is done through RJ45- connectors at the back of the WCAP. Connections can be made to CE2500 or SPL5000. 4. Bracket …. 5. LAN connection Through the LAN connector at the back of the WCAP, a PC can be connected using a standard network cable 6. Status  LEDS The status LEDs give information on selected mode, RF link quality (Signal/Noise Ratio) and delegate unit detection (see Figure 10.6, Table 10.1, Table 10.2 and Table 10.3).   Caution:  Only use antennas supplied by Televic. Use of other antennas can cause damage to the unit, reduce system performance and
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 32 Figure 10.6: LED indicators   Table 10.1: LED 1 (Blue) - Mode OFF N/A SLOW BLINKING Slave mode BLINKING N/A ON Standalone mode  Table 10.2: LED 2 (Red) - RF link quality OFF RF LINK OK SLOW BLINKING 10<SNRAVG<15 BLINKING 5<SNRAVG<10 ON SNRAVG<5  Table 10.3: LED 2 (Red) - Status OFF N/A SLOW BLINKING N/A BLINKING No units initialized ON At least 1 unit has been connected with the WCAP    LED1 LED2 LED3
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 33     Section 3 – System  Configuration
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 35 11. Accessing the built-in web server 11.1. Introduction The WCAP has a built-in web server that allows you to set/monitor certain parameters characterizing the wireless conference system. The following is a step-by-step guide to give you a general idea of how to access your WCAP.   11.2. First time access 11.2.1. Step 1 – Reset  Figure 11.1: Power connection and power switch  Figure 11.2: Reset button  Follow these steps to reset the access point (WCAP)  Unplug ALL connections   Connect the power cord   Activate the WCAP by flipping the power switch to the “on” position  Hold down the reset button for at least 5 seconds using a fine object or stylus.  Using the ON/OFF switch, switch the unit “off” and back “on” for the reset to take effect  After the reset the default settings in the WCAP will be restored. Please refer to appendix x to get a complete overview of all default settings.  24V ON  Note:  This step is only required if the default settings have been altered.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 36 11.2.2. Step 2 – PC or MAC TCP/IP setup  In order to access the built-in web server for the first time the TCP IP settings from the PC or MAC must be modified. A fixed IP address has to be set. Therefore follow the instructions below. Assigning a Static IP Address in WINDOWS XP/2000  Go to the ‘ Control Panel’ (refer to Figure 11.3)  Double-click on Network Connections Figure 11.3: Control Panel   Right-click on Local Area Connections (refer to Figure 11.4).  Double-click on Properties Figure 11.4: Network Connections   Click on Internet Protocol (TCP/IP)  Click Properties  Input your IP Address and subnet mask (refer to Figure 11.5). The IP Addresses on the network must be within the same range. The default IP address from the WCAP is 192.168.0.10 so the computer should have an IP Address that is within the same subnet, like 192.168.0.11 and 192.168.0.20. The subnet mask must be the same for all equipment on the network: 255.255.255.0)  Click OK    Note:  Be sure not to use the IP address 192.168.0.10 for your computer, as this is reserved and used by the WCAP as a default.   Note:  The WCAP has a default fixed IP address and subnet mask:  IP:     192.168.0.10  Subnet mask:   255.255.255.0
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 37 Figure 11.5: TCP/IP properties   Assigning a Static IP Address with MACINTOSCH OSX  Go to the Apple Menu and select System Preferences  Click on Network  Select Built-in Ethernet in the Show pull-down menu  Select Manually in the Configure pull-down menu  Input the Static IP Address and the Subnet Mask Address in the appropriate fields. (The IP Addresses on the network must be within the same range. The default IP address from the WCAP is 192.168.0.10 so the computer should have an IP Address that is sequential, like 192.168.0.11 and 192.168.0.20. The subnet mask must be the same for all equipment on the network: 255.255.255.0)  Click Apply Now       Reference:  Please refer to the documentation that came with your PC or MAC installation for additional information and the correct settings.   Note:  If you have a proxy server or firewall installed on your computer check the connection restrictions to the WCAP IP address and content that uses java scripts. Please refer to the documentation that came with your installation for the correct settings.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 38 11.2.3. Step 3 – Cable Setup   Connect your computer (PC or MAC) to the LAN  port using a straight-through cable.  11.2.4. Step 4 – Accessing WCAP Figure 11.6: Internet Explorer address bar   Open Internet Explorer or any other browser (with the computer connected to the WCAP)   Enter 192.168.0.10 into the Address Bar, push Enter  Figure 11.7: WCAP password page   Leave the Password field blank   Click “OK” 11.2.5. Step 5 – Default Screen After successfully establishing a connection to the WCAP and passing the password screen, the default WCAP screen appears. Figure 11.8: WCAP default screen
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 39 11.3. Setting the IP address After you successfully accessed the WCAP for the first time (refer to 11.2 ‘First time access’) you can customize the TCP/IP settings to allow the WCAP into you own personal or company LAN network.  Select the “TCP/IP settings” sub tab in the “Setup” menu (refer to Figure 11.9)  Figure 11.9: Confidea Setup menu   In the TCP/IP settings - screen you can modify the TCP/IP settings of the WCAP (refer to Figure 11.10). 1. The name of the installed conference system can be customized. 2. The MAC address of the WCAP 3. The IP address mode determines how the WCAP will get its IP address  Static: in this mode the IP address and subnet mask is fixed and must be provided in the appropriate fields.  DHCP: DHCP stands for Dynamic Host Configuration Protocol and is a protocol used by the WCAP to obtain the parameters necessary for operation in an Internet Protocol network automatically. This protocol reduces system administration workload, allowing the WCAP to be added to the network with little or no manual configuration.  4. Here you can enter the desired fixed IP address. Only applicable in fixed IP address mode. 5. Here you can enter the desired subnet mask. Only applicable in fixed IP address mode. 6. Press this button to save the modified values.   Figure 11.10: Screen TCP/IP settings        Note:  The new TCP/IP settings will only be active after repowering the WCAP     Note:  There must be a DHCP server on the network that dynamically assigns IP addresses when using the DHCP setting. 1 2 3 4 5 6
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 40 12. Web server 12.1. Setup 12.1.1. Summary Device information  General device information is summarized in this section.  System Name: Displays the system name. Configured in the TCP/IP settings page.   IP Address: Displays the device IP address.  Subnet Mask: Displays the currently configured IP subnet mask. DNS Servers: Displays IP address for the DNS server.  Address Mode: Displays the protocol used to define the IP address.  Base MAC Address: Displays the device MAC address. System Information  Here you can find information about the components inside the system.  Hardware components and software components each have their own version.   Serial Number: Displays the device serial number.  Model Name: Displays the device model name.  Hardware Version: Displays the hardware version number.  Boot Version: Indicates the system boot version currently running on the device.  Firmware Version: Displays the firmware/software version.  FPGA VHDL Version: Displays the VHDL version for the FPGA.  RF hardware 1 Version: Displays the RF hardware version for the active module.  RF hardware 2 Version: Displays the RF hardware version for the passive module.  RF Firmware 1 Version: Displays the RF firmware version for the active module.  RF Firmware 2 Version: Displays the RF firmware version for the passive module.      12.1.2. TCP/IP settings This is the help text for the TCP/IP settings page Identification  System Name: Defines the user-defined system name.   Base MAC Address: Displays the MAC addresses assigned to the system. IP configuration In this section you can configure how the system will acquire its IP address   IP Address Mode: Retrieves the IP addresses using DHCP or Static. DHCP: Retrieves the IP addresses using DHCP. Static: The IP address is statically defined.   IP Address: Defines the system IP address.   Subnet Mask: Defines the system IP address mask. Note:  Use this information when you contact the service department in case you experience problems with the system.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 41    12.1.3. Admin This is the help text for the Admin page.  Change password Only users that know the password are authenticated to use and consult the Confidea WCAP web pages! In this section the password can be redefined: 1. Enter the OLD password 2. Enter a new password (Max. 50 characters long) 3.  Confirm the new password 4. Submit the values to the server and wait for the result. Note: The old password will work as long as no positive feedback has been received.     Note:  The old password will work as long as no positive feedback has been received.  Note:  Any modification to the settings becomes active instantly. When pressing the ‘Save’ button, the active settings are stored in memory and recalled after power-down.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 42 12.2. RF Configuration 12.2.1. General Power Room size: the transmitted output will be adjusted to cover the configured room size. The system will decide the appropriate power setting when the auto setting has been selected  Frequency The drop down list box allows you to select the frequency on which the system needs to operate. Auto When the ‘Auto’ setting has been selected, the system will decide automatically on which frequency to operate, based on its measurements of the available spectrum. In this way, interference with equipment that operates nearby is avoided. Frequencies listed in BLACK color. When one of the frequencies is selected out of the list, the system will be forced to work on that frequency and will not automatically switch to another channel should interference occur. Frequencies listed in BLUE color. Some frequencies require a special procedure before equipment can occupy the channel. These frequencies are indicated with a blue color. Compliancy with the ETSI EN301893 standard requires a channel availability check on these special frequencies before one of these frequencies can be used. This also implicates that, although an operating frequency has been manually selected, the system will still switch to another available channel when a radar signal or other interfering signal has been detected on that channel.   Frequencies listed in RED color. Some frequencies will be marked in red indicating that an interfering signal was detected on that channel. The interference severity can be monitored in the quality pages. 12.2.2. Quality 2.4 GHz ISM Channel Quality On this webpage the expected quality for each possible RF channel in the 2.4GHz ISM band can be monitored. This visualization of channel availability and quality helps to select a fixed RF channel in case the system is set not to work in automatic mode. 12.2.3. Quality 5.15 –  5.35 GHz On this webpage the expected quality for each possible RF channel in the 5.15-5.35 GHz band can be monitored. This visualization of channel availability and quality helps to select a fixed RF channel in case the system is set not to work in automatic mode. 12.2.4. Quality 5.47 – 5.725 GHz On this webpage the expected quality for each possible RF channel in the 5.47-5.725 GHz band can be monitored. This visualization of channel availability and quality helps to select a fixed RF channel in case the system is set not to work in automatic mode.  Note:  The channel availability check takes 60 seconds. During that time delegate units cannot connect to the Confidea Access Point
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 43 12.2.5. Quality 5.8 GHz ISM On this webpage the expected quality for each possible RF channel in the 5 5.8 GHz ISM band can be monitored. This visualization of channel availability and quality helps to select a fixed RF channel in case the system is set not to work in automatic mode.      Note:  From time to time, the Confidea system will also measure its own activity in the channel on which it is currently operating. This results in a RED indication on the corresponding bar graph, but does not affect the reliable operation of the system. Note:  The channel availability is visualized using colors:  A full GREEN bar indicates the channel is available 100% of the time. This channel is thus safe to use.  A full RED bar indicates the channel is fully occupied by other radio devices. This channel should not be used to operate the Confidea system.  The more activity on a channel, the more the corresponding bar will color RED, and thus the more likely interference will occur with other systems.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 44 12.3. Conference Management 12.3.1. General Conference Configuration  Maximum Number of Active Microphones: Defines the maximum number of simultaneous active microphones. The system can handle a maximum number of 8 active microphones.     Microphone Mode:  Defines the conference mode. With Request: Enables the participant to send a request to speak to the chairman or conference operator by pressing the microphone button (or to cancel his request by pressing the microphone button again). Once the floor is requested, the green LED above the microphone button will flash. This means that the conference unit is in request mode.  The chairman or conference operator grants the participant the permission to speak by using the NEXT button or by clicking the green microphone on the computer screen in case the Confidea system is connected to a central unit and PC control software is used. While the conference unit is in request, the red signal ring of the microphone will flash.   With Request No Clear:  Enables the participant to send a request to speak to the conference operator or chairman. However, he cannot cancel his request. The chairman or conference operator grants the participant the right to speak by using the NEXT button or by clicking the green microphone on the computer screen in case the Confidea system is connected to a central unit and PC control software is used.  While the conference unit is in request, the red signal ring of the microphone will flash.  Direct Access:  Enables the participant his microphone to turn on or off at any time. The only limitation here is the maximum number of microphones which may be active simultaneously.  FIFO: In this conference mode, only one microphone can be active at a time without intervention of the conference operator. Activation of another microphone switches of the current active microphone.  The only exception here is that the microphones of a delegate and the chairman can be active at the same time.  Override:  Works like the FIFO mode; however multiple microphones can be active at the same time. The number of microphones that can be active simultaneously is set by "Maximum Number of active Microphones" setting. When the maximum allowed number of microphones are switched on, activation of an additional microphone will automatically switch off the microphone that was active for the longest time. Again, the Chairmen units can always be activated, regardless of the number of microphones already switched on. Note:  Choosing a high number of active microphones will limit the number of interpretation channels.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 45  Group 1:  Enables one microphone at a time to be active without a request for activation. Other participants can switch their microphone in request mode; the first applicant gets the floor when the delegate who has the floor turns off his active microphone or when the chairman or conference operator grants the participant the permission to talk by using the NEXT button or by clicking the green microphone on the computer screen.  Group 2: Enables two microphones to be active at the same time. Other participants can switch their microphone in request mode; the first applicant who requested the floor gets the floor when one of the currently active microphones is turned off or when the chairman or conference operator grants the participant the permission to talk.  Group 3: Works exactly like Group 1 and Group 2, with the alteration that three participants can have the floor at the same time.  Group 4: Works exactly like Group 1 and Group 2, with the alteration that four participants can have the floor at the same time.     Volume: Defines the loudspeaker volume. Interpreter Configuration Defines the number of broadcasted interpretation channels.  A maximum of 16 interpreter channels can be set.    Note:  Although it is possible to select the highest setting of number of active microphones together with the highest number of interpretation channels, it is advised to use the settings that are not marked in red! Note:  Choosing a high number of interpretation channels will limit the number of maximum microphone channels.   Reference:  When using Confidea in conjunction with other Televic conference systems and PC control software, please refer to the User Manual of those systems for more information on the use and setting of the various conference modes. Note:  If the Confidea system is connected to a Televic conference system central unit, the conference mode settings will be managed from that central unit.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 46 12.3.2. Unit Monitoring Init State  Units Initialized: Displays the number of initialized units currently linked to the system.  Units in Init List: Displays the total number of initialized units. Unit List In this section a unit summary is displayed.  Microphone Number:  Displays the microphone number.  Serial Number:  Displays the unit serial number.  Status:  Displays the unit status. Units can either be ‘Connected ‘or ‘Disconnected’.  Link Quality:  Displays an indication of the quality of the radio link the unit and the Confidea access point. The quality is expressed as Excellent, Good, Fair and Low.   Battery Status: Displays the remaining battery capacity. The value indicates how many hours the unit can still be used before the rechargeable battery is depleted.    12.3.3. Init Units Init State  Units Initialized:  Displays the number of initialized units currently linked to the system.  Units in Init List:  Displays the total number of initialized units included in the list Init Init Control:  Open Access: When the system is set to ‘Open Access’ any delegate or chairman unit that powers up within the range of a Confidea Access Point will log itself on to that access point, and its ID will be added to the Init List  Manual: In manual mode, each units needs to be initialized manually before it is added to the Init List.  ‘Start Init’: Pressing this control will start an initialization cycle. Pressing the microphone button of each unit that needs to log on to the system will register that unit with the Access Point.  ‘Save and Stop Init’: This will stop the initialization and save the init list to memory. To add more units, restart the init cycle. Note:  During the first minutes a unit is switched on, the battery status is not accurate and higher values can be displayed. This is normal and due to the typical behavior of batteries. Note:  The information on the unit monitoring page is not refreshed automatically. To view the most recent condition of the system, click the “Refresh Unit Table” button.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 47  ‘Clear Init List: This will clear the init list and allow you to start from scratch to build an init list.   12.4. Service 12.4.1. Logging Log List On this web page, a list of events are displayed that occurred in the access point. This will help to diagnose the system when necessary.  Start:  This button starts capturing the access point events.  Stop:  This button stops capturing the access point events.  Clear:  This button will clear the events that were previously captured. Use the MS Windows Copy-Paste facilities to export the log list. 12.4.2. Update Firmware RF module 1 Choose a file and click the update button to program the firmware for the first RF module Firmware RF module 2 Choose a file and click the update button to program the firmware for the first RF module Firmware Access Point Choose a file and click the update button to program the firmware for the access point   12.5. Encryption 12.5.1. Key Assignment Introduction To ensure a highly secured wireless system, the Confidea system uses an encryption algorithm and mechanism that is fixed and cannot be changed. The information that is sent over the radio link is encrypted with a key to make it inaccessible for 3rd party equipment. This key is default and identical for all Televic units. Security can be increased by adding a custom key, that is specific to a certain set-up or installation. Only the units and access point that share the same encryption key are able to communicate with each other. In this way, the system has become customer exclusive and as a result an even higher degree of security has been reached. Encryption Key  Default Key: When selecting this key, information over the wireless link is encrypted, using the Televic default key, used by all Televic equipment  Custom Key: To further increase security, or to limit the access to the Access Point only to a well controlled number of delegate units, a custom key can be generated and send to those units that are allowed to join. The result of this action is that only the units that know this key can   Caution:  Updating of firmware is not without risk and should only be performed by, or under the strict guidance of, qualified personnel.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 48 access the system and participate in the conference   ‘Calculate128 bit full’ key: Pressing this button will randomly generate a 128 bit key. The key appears in the window and can still be edited by the user.  ‘Upload’ key: Pressing this button will upload the custom key to all units, currently logged on to the system. Units can only obtain the customer specific key during initialization. As soon as the initialization has been closed it will not be possible to access the system with other units.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 49 13. Initialization 13.1. Introduction The system can be controlled by the WCAP in stand-alone mode or together with the TCS2500 / TCS5500 Central unit in coupled mode.  In stand-alone mode it is not required to initialize the units. However, if you want to authorize the wireless units that will be connected into the system you can follow the unit initialization procedure.  In coupled mode, the same initialization procedures have to be followed as defined in the documentation from the central unit. To personalize the system and to further extend the confidentiality of your wireless conference system a unique encryption key can be defined. 13.2. Stand-alone mode 13.2.1. Access modes When you use the Confidea system in stand-alone mode, i.e. with no connection to a TCS2500 or TCS5500 central unit, the WCAP is responsible for the unit initialization and access control. In stand-alone mode, the WCAP supports two kinds of access: open access and controlled access.  Open access: This is the default mode. Any unit can connect to the WCAP without authorization procedure  Controlled access: a unit can only connect after going through an initialization and authorization procedure.  13.2.2. Selecting the Access Mode To select the desired access mode go to the “Init Units” sub tab in the “Conference Management” menu from the web server (refer to Figure 13.1) Figure 13.1: Web server init page selection  The following screen will appear: Figure 13.2: Unit init page
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 50 To select ‘Open Access’ click the radio button next to ‘Open Access’ on the ‘Init Units’ page (refer to  Figure 13.3) Figure 13.3: Init units page - Open access  Select this mode if the wireless units are not required to be authorized, before they are allowed to connect with the WCAP.  This mode is especially useful for a fast setup.   To select ‘Controlled Access’ click the radio button next to ‘Manual’ on the ‘Init Units’ page (refer to Figure 13.4) To control which wireless units connect with the WCAP a manual initialization of the units is required.  Figure 13.4: Init units page - Manual   13.2.3. Unit initialization in ‘Open Access’ mode Switch on all wireless units and wait a few seconds until the units have discovered the WCAP (see chapter xxx) All active wireless units will automatically connect with the WCAP and join the conference. 13.2.4. Unit initialization in ‘Controlled Access’ mode In this mode, a manual initialization is required. The manual initialization procedure requires the use of the 3 buttons on the web server displayed above: “Start Init”, “Save and Stop Init” and “Clear Init List”. Take the following steps to initialize all units: 7. Switch on all wireless units and wait a few seconds until the units have discovered the WCAP (see chapter xxx)  8. Select the “Clear Init List”, , to clear any previously created initialization list. 9. Start the new initialization by selecting the “Start Init”,  ,button. After you started the new initialization, the LED’s on all wireless units will start to blink.  10. To add a unit to the initialization list, press the microphone button of the unit to add.   11. The LEDs will go out indicating that the unit has been added to the list. 12. Repeat step 3 for each unit that needs to be added. 13. When finished, stop and save the initialization by pressing the “Save and Stop Init” button,.   Note:  Avoid using Open Access in areas with more than one active Confidea system, as there is no control over which WCAP the delegate units will connect to.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 51 Only the units that are have been initialized and listed in the Init List will now be able to join the conference. The init list is stored in the WCAP and stays in memory even after switching the WCAP off. Next time the WCAP and delegate units are switched on, only these units that are in the Init List will be allowed to connect to the WCAP. 13.2.5. Adding a new unit in ‘Open Access’ mode In ‘Open access’ mode, adding a unit requires simply to switch the unit on. It will then automatically connect to the WCAP in operation.   13.2.6. Adding a new unit in ‘Controlled Access’ mode In a ‘Controlled Access’ set-up, adding a unit requires the following steps: 14. Switch on the wireless unit to add and wait a few seconds until the unit has discovered the WCAP (see chapter xxx) 15. Open the existing initialization by selecting the “Start Init”, , button. 16. After you started the new initialization, the LED’s on the wireless unit(s) will start to blink. The LED’s on the units that are already known in the init list will automatically go out. 17. Add the new wireless unit(s) by pressing the microphone button on the unit(s).    18. Stop and save the initialization by pressing the “Save and Stop Init” button,  .    Note:  When multiple WCAPs with ‘Open Access’ are in operation in the same area, there is no control over which WCAP the new unit will connect to.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 52 13.2.7. Reviewing Init information At any time it is possible to see how many units are known by the system, “Units in Init List”, and to see which units are actually connected with the WCAP, “Units Initialized”. This information is visible in the “Unit Monitoring” and “Init Units” sub tabs in the “Conference Management” menu (see Figure 13.2) Figure 13.5 shows the information on the screen when 1 unit is listed in the Init List but not connected with the WCAP: Figure 13.5: Init example 1  Figure 13.6 shows the information on the screen when 1 unit is listed in the Init List and this unit is switched on and connected with the WCAP: Figure 13.6: Init example 2  13.3.  Coupled mode If the WCAP is used in combination with a wired central conference unit, e.g. TCS2500 or TCS5500, then the initialization procedure explained for that wired unit has to be followed.           Reference:  Refer to the manual of the connected central unit for the initialization procedure   Note:  The Init control like displayed in the web server has no functionality when the WCAP is coupled with another wired conference unit.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 53 14. Encryption 14.1. Introduction To secure all communication between the WCAOP and the wireless delegate units, all information that is passed over the radio link is encrypted by default, using a default encryption key. This key is identical for all Televic equipment. To this default key, a custom encryption key can be added. This further enhances the confidentiality, but can also be used to control access in an environment where multiple adjacent rooms are using a Confidea conference system. In this way, access can be restricted to a single room or a selection of rooms. The custom key as it were adds a unique relationship between a wireless unit and a given access point. 14.2. Default encryption By default the system uses an encryption mechanism that is known by each unit in the wireless conference configuration. By using this setting it is possible to add new units in the conference configuration or using the delegate units with other WCAP’s at any time (also see Initialization)    14.3. Setting the default encryption The default encryption mechanism can be set by following these steps: 19. Select the “Key assignment” sub tab in the “Encryption” menu from the web server. Figure 14.1: Web server key assignment page selection  The following screen will appear: Figure 14.2: Key assignment page  20. Select the “Use default key” option to return to the default encryption mechanism Figure 14.3: Default key selection      Note:  The advanced encryption mechanism used in the Confidea system makes decryption by third party equipment practically impossible.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 54 14.4. Custom encryption The Confidea wireless conference system can be personalized by defining and selecting a unique encryption key.  By using a customized key, only the units that have this key, i.e. on which the specific key has been uploaded, can connect with the WCAP. All other units will be rejected.  It is impossible to receive the transmitted audio signal with a unit that does not have the customized key. Up to 3 (TBD) customized encryption keys can be defined.   14.5. Setting a customized encryption To set up your system with a custom encryption key, carefully follow these steps: Step 1 - Check your configuration Before uploading the custom key check if all units in your system are switched on and connected to the WCAP. Verify if the correct number of units is logged-on by checking the “Units Initialized” number which can be found under the “Unit monitoring” or “Init Units” sub tabs in the “Conference management” menu. Please refer to the initialization chapter (ref.) for more information.  Step 2 – Go to the Key assignment web page  Select the “Key assignment” sub tab in the “Encryption” menu from the web server (refer to Figure 14.1.) The key assignment page will appear (refer to Figure 14.2) Step 3 – Enter a new encryption key In this example we will modify custom key 1. To manually enter a new custom key, choose a 32-character long encryption key and manually enter it in the text box next to the “custom key 1” mark (refer to Figure 14.4).   Note:  If delegate units have received custom keys in the past, it may be necessary to select the default encryption mechanism first, (refer to chapter 14.3 Setting the default encryption) to allow each unit in the system to access the WCAP.   Note:  Once uploaded to the delegate units, custom keys cannot be retrieved from the system.    Note:  The basis of the encryption mechanism cannot be altered, so adding a custom key does not affect the encryption strength. Default- and custom encryption yield an encryption strength that is equally high.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 55  Alternatively, the system can generate a random 128-bit (32 hex characters) encryption key for you.  To do this, click the “Calculate 128-bit full key” button (refer to Figure 14.4).  Figure 14.4: Custom key entry field  Step 4 – Upload a new encryption key After a key has been generated it must be uploaded into the system. Not only the WCAP, but also all wireless delegate units that need to connect with the WCAP must know the same key. Upload the key by clicking the “Upload key” (refer to Figure 14.4)    Step 5 – Activating the new encryption key The WCAP will start encrypting the transmitted data and audio after a custom key has been selected. Figure 14.5: Custom key selection   If the WCAP needs to use the selected key next time it powers up, push the   button.    Caution:  Wireless units not containing the same encryption key as selected, because they were not connected with the WCAP at the time of upload, can no longer connect with the same WCAP.  The units will be ignored by the system!    Caution:  Only the units that are connected with the WCAP can receive the newly generated encryption key. Other units will be ignored!    Note:  During the upload, the microphone LEDs will flash. Once the upload is successful, the LEDs go out.    Caution:  Only use hexadecimal characters i.e. choose 32 characters from the following list:  0, 1, 2, 3, 4, 5, 6, 7, 8, 9, a, b, c, d, e, f. If a key shorter than 32 characters has been entered, then the remaining positions will be filled with zeros. If a key longer than 32 characters has been entered, then the key will be truncated after the first 32 characters.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 56 14.6. Adding a unit with a customized encryption  14.7. Using multiple customized keys
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 57     Section 4 – Use Cases
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 59 15. Stand alone system 15.1. Basic discussion In a basic setup where only discussion is applicable, the Wireless Conference Access Point WCAP (see link to chapter WCAP) acts as a central control unit. This means the system can operate without the need of an extra central control unit (CE2500 or CPU5500). Units applicable to this setup are listed below:  Confidea DD  Confidea CD In a standalone configuration power needs to be supplied to the WCAP separately. (see chapter WCAP power supply) Configuration and monitoring of the system can be done via the build-in web server, which is accessible via a standard web browser. (See chapter system configuration)         Figure 15.1: Stand alone set up for basic discussion Note:  In this case the chairman needs to guide the meeting by using his prior and next-inline button. Microphone activation by an operator is not possible via web server application.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 60 15.2. Basic voting and opinion polling In a setup where there is only a need for basic voting or opinion check, the Wireless Conference Access Point WCAP (see link to chapter WCAP) acts as a central control unit. This means the system can operate without the need of an extra central control unit (CE2500 or CPU5500). Units applicable to this setup are listed below:  Confidea DV (Figure 6.1 and Figure 6.4)  Confidea CV In a standalone configuration power needs to be supplied to the WCAP separately. (see chapter WCAP power supply) Configuration and monitoring of the system can be done via the build-in web server, which is accessible via a standard web browser. (See chapter system configuration)     Figure 15.2: Stand alone set up for opinion polling Note:  In this case the chairman needs to guide the meeting by using his prior and next-inline button. Microphone activation by an operator is not possible via web server application.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 61 Chairman has control over the voting session.  With the voting session control buttons (see Confidea Wireless units - Controls and indicators) he can start, pause or stop a voting session. Figure 15.3: Voting control buttons   After pressing the stop button, the voting session is terminated and the results are distributed to the information display of all registered Confidea units. Figure 15.4: Voting information display   Pressing the stop button a second time clears the voting results.     Note:  The voting results are not stored in a file in this setup.  In case there is a need see use case CE2500 or CPU5500
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 62 16. Connected to CE2500 or CPU5500 As the Confidea system is an addition to the Televic product family it is also possible to combine the Confidea system with the existing TCS2500 and TCS5500 system (refer to Figure 16.1: Televic Family concept) This family approach makes it possible to create a conference system fitting every customer needs.  In situations where every now and then an extension of the fixed conference system is required, adding some wireless units can reduces the setup costs drastically. Depending on the demands of a project the central control equipment of the TCS2500 or TCS5500 does the job. The Confidea access point (WCAP) can be directly connected to one of the digital output busses of the TCS2500 central control unit. (CE2500/B) Connecting the Confidea access point to the central control equipment of the TCS5500 requires an additional splitter unit (SPL5525). In the following section three possible applications are described.  This will help to define the correct system architecture for a given project.   Figure 16.1: Televic Family concept       Reference:  When using Confidea in conjunction with other Televic conference systems and PC control software, please refer to the User Manual of those systems for more information.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 63 16.1. Discussion For these applications, delegates of the meeting have a contribution unit with only a microphone to participate in an ongoing discussion. Several criteria can influence the choice of the Televic central control unit to be used.  The criteria described below should guide you in designing the best possible system architecture for a given project.       Figure 16.2: Central control equipment selection criteria    Project size The number of participant units in a meeting will influence the descision on the system to use. The TCS2500 central control unit is limited up to 120 active delegate units. Projects requiring a larger number of participants should use the TCS5500 central control unit with expandable system architecture. Table 16.1 below gives an overview on the system compatibility. Table 16.1: Project size vs. Televic system Number of Participants TS2500 TCS5500 <50 • (CE2500/B) • 50 > 120 • (upgrade full option) • > 120  •
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 64 External Audio Peripherals PA systems: Whereas the Confidea units have a build in loudspeaker, some meeting rooms are equipped with external PA systems with loudspeakers installed on walls or in ceilings. Making use of such a setup, the floor language of the conference system needs to insert into the PA system. This requires an analog output, which is available on the central control equipment of both TCS2500 and TCS5500. Recording: Whenever meetings reports need to be written or audio of meetings is being published on the web, recording needs to take place during the meeting. The recording device (hardware or software solution) needs to have an analog input signal provided by the conference system. Both the Televic TCS2500 and the TCS5500 central control units have 7 analog outputs available. Additional outputs can be provided by adding external TCS5500 output equipment to the TCS5500 system. Audio reproduction: Feeding external audio signals (music before meeting, DVD sound, input external microphone, telephone line, …) into the conference system requires analog inputs on the central control unit. Both the TCS2500 and TCS5500 central control units have two analog inputs.  If this is not sufficient the TCS5500 system has the capability to connect additional input equipment. Table 16.2: I/O Equipment vs. Televic system I/O TS2500 TCS5500 Input 2 2 Expandable Output 7 7 Expandable Connectivity Operator Control: Systems requiring a great degree of control can be equipped with the Televic software suite. This application makes it possible, depending on the license, to control the microphones in a meeting, assign delegate names, control speech time, display delegate and speech time information on monitors or projection screens. It offers easy initialization and configuration capabilities supporting an easy set-up and break-down, essential for successive meeting planning with low delays like convention centers. Furthermore it visualizes the battery and RF quality status of all units, giving the operator/technician the ability to assure no interruptions once the meeting started. Camera Control To enable a camera system to visualize the currently active Confidea user, a device bus controller needs to translate the commands received from the Televic system into preset positions of the camera control system. Both the TCS2500 and TCS5500 systems will do the job. The difference between the TCS2500 and the TCS5500 system on connectivity level is the way the communication takes place. The TCS2500 uses a serial communication protocol, whereas the TCS5500 system has additional IP connectivity.  (Refer to Table 16.3: Connectivity vs. Televic System) Table 16.3: Connectivity vs. Televic System Connectivity TS2500 TCS5500 RS232 • • TCP/IP  •
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 65 16.2. Advanced Voting The stand alone voting setup can be seen as an informal voting session. Making use of a Televic voting software suite enables following features:  Voting agenda  Voting session configuration options  Voting result reporting  Voting logging  Voting result visualization All of these options are available for as well TCS2500 as TCS5500 systems. Main differences between the two systems are:  Voting by authority  Customizable voting result visualization Table 16.4: Voting vs. Televic system Voting TS2500 TCS5500 Authority  • Result visualization fixed customizable  16.3. Interpretation Systems with simultaneous interpretation as a requirement always require a central control unit  in combination with the interpreter desks. Installation Whereas the TCS2500 interpreter desks are of the table-top type, the TCS 5500 interpreter equipment can be semi-flush mounted. Conformity Standard The ID5500 interpreter desk is conform to the XXXXX standard and approved by interpreter organizations as the European Commission (SCIC), United Nation, AIIC. Interpretation capabilities The Confidea wireless system has the capability to send up to 12 languages to the contribution units. Both the TCS2500 and TCS5500 systems are capable of handling that number of languages. External Equipment As already described in External Audio Peripherals the number of analog outputs required for recording or needed to connect to an Infra red distribution system will determine the central equipment to be used. Table 16.5: Interpretation vs. Televic system Interpretation TS2500 TCS5500 Installation Table-top Semi-flush mounted Standard xxxx xxxx # languages Confidea : 12 Confidea : 12 # outputs 9 Expandable  Next to these points it is also possible to connect interpreter systems of other vendors. That way it is
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 66 possible to use the Confidea system without the need to change all the interpreter desks. The PIO unit of the TCS5500 plays an imported role in such configuration handling the floor and interpretation languages between the two systems.
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 67     Section 5 – Appendix
Confidea Wireless System Installation and User Manual   Televic Conference Systems 2008-09-05 69