Technalogix TM100 Modulator User Manual TM 100oct03

Technalogix, Ltd. Modulator TM 100oct03

Manual

                                                                                       TM-100 BROADCAST MODULATOR OPERATING MANUAL Technalogix
  Technalogix Ltd.                                                 TM-100 Modulator 1               TABLE OF CONTENTS    1.0 SAFEGUARDS ..................................................................................................................... 2  General Safeguards................................................................................................................ 2 Safety and First Aid................................................................................................................. 3  2.0 WARRANTY ........................................................................................................................ 4  3.0 DESCRIPTION AND SPECIFICATIONS .................................................................................... 5  General Description ................................................................................................................ 5 Available Options .................................................................................................................... 6 Specifications.......................................................................................................................... 6 Video Conditioning Module..................................................................................................... 9  4.0 INSTALLATION .................................................................................................................... 9  Building Recommendations.................................................................................................... 9 Heating and Cooling Requirements........................................................................................ 9 Electrical Service Recommendations................................................................................... 10 Antenna and Tower Recommendations............................................................................... 10 Shelter Security..................................................................................................................... 11 Unpacking and Inspection .................................................................................................... 12 Location and Function of Controls and Connectors............................................................. 13  5.0 OPERATING PROCEDURE.................................................................................................. 15  Preliminary Hook-up ............................................................................................................. 15 Setup and Operation............................................................................................................. 15 Transmitter Hookup .............................................................................................................. 18  6.0 BILL OF MATERIALS, SCHEMATICS, AND PCB OVERLAYS ................................................ 20  Agile Logic Board.................................................................................................................. 20 Agile Output Amplifier Board ................................................................................................ 25 Audio Video Modulator Board............................................................................................... 28 Digital Up converter Board.................................................................................................... 37 750 MHz Down Converter Board.......................................................................................... 43 Power Supply Board ............................................................................................................. 49
  Technalogix Ltd.                                                 TM-100 Modulator 21.0 SAFEGUARDS  General Safeguards  This section is written as a general guide for those having previous knowledge and experience with these kinds of equipment.  It is not intended to contain a complete statement of all safety precautions, which should be observed by personnel using this or other electronic equipment.  To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture.  Do not open the cabinet.  Refer servicing to qualified personnel.  1. READ INSTRUCTIONS - All safety, installation, and operating instructions should be read before the equipment is operated.  2. RETAIN INSTRUCTIONS - The safety and operating instructions should be retained for future reference.  3. FOLLOW INSTRUCTIONS - All safety, installation, and operating instructions should be followed.  4. GROUNDING AND POLARIZATION - The TM-100 Modulator is equipped with a three prong grounded power plug.  Do not remove the ground prong from the plug. Do not use an AC receptacle where the plug blades cannot be fully inserted.  5. SERVICING  - Do not attempt to service this equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards and will void the warranty.  Refer all servicing to qualified service personnel.  6. DAMAGE REQUIRING SERVICE - Unplug this equipment and refer servicing to qualified service personnel under the following conditions: • if the power cord or plug is damaged. • if liquid has been spilled or objects have fallen into the equipment. • if the equipment has been exposed to rain or water. • if the equipment does not operate normally by following the operating instructions. Adjust only those controls covered by the operating instructions.  An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the equipment to its normal operation. • if the equipment has been dropped or the cabinet has been damaged. • if the equipment exhibits a distinct change in performance.
  Technalogix Ltd.                                                 TM-100 Modulator 3Safety and First Aid Personnel engaged in the installation, operation, maintenance, or servicing of electronic equipment are exposed to the hazard of high voltage.  It is imperative that all safety regulations and precautions are consistently observed.  Knowledge of first aid procedures is recommended.  The following information is presented as a reference only.  • At all times, avoid placing any part of the body in series between ground and circuit points, whether power is on or off.  • Dangerous voltage may be present in equipment even though power is off.  Do not open the cabinet.  Refer servicing to qualified service personnel.  • It is the duty of all personnel to be prepared to give adequate emergency first aid treatment and thereby prevent avoidable loss of life.  • There are three principle degrees of burns, recognizable as follows: • a first-degree burn reddens the skin. • a second-degree burn blisters the skin. • a third degree burn chars the flesh and frequently places the victim in a state of shock accompanied by respiratory paralysis.  • Respiratory paralysis can cause death by suffocation within seconds.  It is imperative that the approved methods of artificial respiration are initiated immediately and continue until the victim’s breathing is normal.  • A muscular spasm of unconsciousness may render the victim unable to break free of the electric power.  If this is the case, turn the power off immediately.   DO NOT TOUCH THE VICTIM OR YOU MAY SHARE THE SAME PREDICAMENT.  • If the power cannot be turned off immediately, very carefully loop a dry rope, article of clothing, length of strong cloth or a rolled-up newspaper around the victim and pull the victim free of the power source.  Carefully avoid touching the victim or clothing.  • Once free of the power source, the victim must be placed in a reclining position and covered with a blanket or newspapers to keep warm.  At the first opportunity, enlist help in summoning a doctor.  If a doctor cannot be summoned, transport the victim to the doctor or a hospital.  Be sure the victim is kept well covered and warm while awaiting professional treatment.
  Technalogix Ltd.                                                 TM-100 Modulator 42.0 WARRANTY  Technalogix Ltd. products have been completely tested and found to meet specifications and be in proper operating condition.  They are warranted to be free from defects in materials and workmanship for a period of one year from the date of shipment.  Technalogix Ltd. will not be liable for damages of whatever nature arising out of or in connection with the equipment or its use thereof. Technalogix does not assume responsibility for injury or damage resulting from the practices of untrained or unqualified personnel in the handling of this equipment.   Technalogix Ltd. warranty does not include:  • misuse, neglect or accident. • incorrect wiring and /or improper installation. • unauthorized repairs, modifications or use in violation of instructions issued by Technalogix. • incidental or consequential damages as a result of any defect. • reshipment cost or insurance of the unit or replacement units or parts. • acts of God.  Technalogix agrees, at our option, to remedy warranted defects or furnish a new part in exchange for any part of a unit which, under normal installation, use and service, becomes defective. The user will pay for transportation costs to and from the repair center.  To claim your rights under this warranty:  • Contact Technalogix and describe the problem in as much detail as possible.  See troubleshooting section in this manual.  If a solution cannot be found at this time, it may be determined that the unit will have to be returned to Technalogix for repair.  • Package equipment carefully for prepaid shipment to Technalogix.  Include a written description of the problem experienced and a copy of the original invoice establishing warranty status.  Technalogix reserves the right to make revisions in current production of the equipment and assumes no obligation to incorporate these changes in earlier models.
  Technalogix Ltd.                                                 TM-100 Modulator 53.0 DESCRIPTION AND SPECIFICATIONS  General Description  The high output modulator eliminates the need for preamplifiers prior to the power amplifier system. The modulator processes baseband audio and video information to provide an IF output consisting of a visual IF carrier at 45.75 MHz, using amplitude modulation, and an aural IF carrier at 41.25 MHz, using frequency modulation. An internal upconverter translates the modulator circuitry’s IF carriers to VHF and UHF television frequencies.  All operating controls are located on the front panel, as described in a later section. An aural loop through is provided to properly set transmitter power.   Standard Features  • Totally microprocessor controlled with self-diagnostic monitoring. • Selectable output channels:  § Standard Broadcast VHF 2 – 13, UHF 14 – 60, T7 – T13 § HRC channels 1 through 118 § ±10 kHz offsets  • SAW filtered IF designed for adjacent channel operation. • + 60 dBmV output using low distortion hybrid amplifiers. • Synthesized oscillators – crystal referenced phase locked. • Bar graph modulation and digital LED readout. • Internal switch selects standard or HRC output. • Surface mount technology construction. • RF muted during tuning. • Optional aural sub-carrier and baseband audio input • Phase lock loop FM audio. • BTSC stereo compatible. • External separate audio/video and composite IF loop-through. • RS-232 control option (daisy-chain capable) • Sound carrier level adjustable –10 dB to –20 dB. • Video delay predistortion network meets FCC 73.687. • High stability TCXO, ± 250 Hz • Non-volatile memory retains channel selection after power loss. • Video Detection turns off carrier in event of loss of video.
  Technalogix Ltd.                                                 TM-100 Modulator 6Available Options   • 4.5 MHz sub carrier and baseband audio inputs.  • Dual RS-232 control with daisy chain capabilities that allow for remote control by PC workstation.   HRC Output Frequency Set:  This Technalogix frequency agile product can be set for HRC frequency output. This feature is controlled by an internal dip switch assembly, DS-1. The switch is located near the right front corner (with the panel facing you) between the test point and the output converter module. DS-1 is clearly marked on the PCB. Switch #3 placed in the OFF position switches the output frequency to HRC on all channels. The switch is normally set to ON at the factory.   Specifications  RF Characteristics  Frequency range 7 to 750 MHz Frequency Response (one channel) ±0.5 dB Frequency Stability ±250 Hz RF Output Level +60 dBmV max Output Impedance 50 Ohms Harmonics > 60 dB below rated power Predominant Intermodulation Distortion dBc = decibels below visual carrier + 920 kHz > -53 dBc - 920 kHz > -53 dBc + 2.66 MHz > -53 dBc - 2.66 MHz > -53 dBc + 5.42 MHz > -53 dBc + 7.16 MHz > -53 dBc 3rd Order Intermodulation Distortion   + 4.5 MHz > -60 dBc + 9.0 MHz > -60 dBc All others > -60 dBc Spurious Emissions > -60 dBc
  Technalogix Ltd.                                                 TM-100 Modulator 7NTSC Video Characteristics  Input Level to modulator (for 87.5% modulation) 1.0 VPP Differential Phase (at 87.5% modulation) ±2 Degrees Differential Gain (at 87.5% modulation) 2% Group Delay < ±40 nS Video Group Delay Pre-emphasis Conforms to IC/FCC specifications K-Factor 1.9% for 2T Pulse Hum and Noise > 60 dB below rated power  Aural Characteristics  Input: 50 Hz – 15 KHz 0 dBm (0.8V) Impedance 600 ohms, balanced Frequency Response +/- 1.0 dB Frequency Tolerance, +/- 500 Hz 4.5 MHz Frequency Deviation +/- 25 KHz Harmonic Distortion 1% max Preemphasis (mono) 75 µs Internally Defeatable      IF Section  Output Impedance 75 ohms, unbalanced Video IF level + 37 dBmV, +97 dBµV Audio IF Level +22 dBmV Adjustable +82 dBµV  Return Loss > 14 dB IF Frequency, Video Carrier 45.75 MHz IF Frequency, Audio Carrier 41.25 MHz Video Sound Spacing + 4.5 MHz Vestigial side-band width 0.05 MHz Second IF Frequency 945.75 MHz  Physical Characteristics   Power Requirements 100-130, 210-230 VAC, 50/60 Hz Operating Temperature 0 - 50°C Weight 12 lbs Dimensions (modulator only) W-19", D-14 ", H 1.75”, 1U-high
  Technalogix Ltd.                                                 TM-100 Modulator 8 Video Conditioning Module  The TM-100 modulator includes a separate circuit board called the Video Conditioning Module.  The baseband video signal passes into the modulator, through a group delay filter, and onto the video conditioning Module circuit board.  This module accomplishes two processes:  1. Sync Stretch.  Allows the user to adjust the sync level to maintain the proper level.  Adjustment is made via potentionmeter VR2 and can be made through the ventilation holes in the modulator lid without having to remove the lid.  Potentionmeter VR1 adjusts the video modulation level and must be made by either removing the lid and adjusting VR1 or by the Video Modulation adjust on the front panel of the modulator.  The sync stretch is powered by +5Vdc  brought in to the connector and  –5Vdc, which is generated on board by U1.  2. Video Detect.  Turns off the 24Vdc supply to the final amplifier in the TM-100 in the event of missing video input.  The power supply for the final amplifier (+24Vdc) is routed through a relay on the circuit board.  In the event of a missing video signal, the relay contact is opened and the +24Vdc is disconnected from the final amplifier.  The input and output impedance of the Video Conditioning Module is 75-ohms and video connections are made via RCA connectors.  The video Conditioning Module can be bypassed, if necessary
  Technalogix Ltd.                                                 TM-100 Modulator 94.0 INSTALLATION  This section contains installation recommendations, unpacking, inspection, and installation instructions for the Technalogix TM-100 Modulator. Carefully read all material in this section prior to installation. Also read and review operating procedures later in this section.  Building Recommendations  The quality of the building is of great importance if you are to expect long life and continued performance from the modulator. The building must be clean, dry, temperature controlled and secure. The modulator takes up a single 1-U high space on a 19” rack. Don’t forget to allow space in the building for any additional racks to house test equipment, a workbench area, line regulating transformers, ladders, equipment and parts storage, first aid kit, emergency generator if used, as well as heating and cooling devices that may be unique to your installation. A sloping roof will tend to develop leaks less rapidly. The building should be well roofed with good material. The cooling load will be lowered with reflective or light colored roofing material.  Heating and Cooling Requirements  The environment’s temperature will contribute greatly to the length of the modulator’s life. Technalogix recommends that the building’s filtered air intake must have capacity for all air-flow in the building plus an additional 20%.  Keep the intake below the roofline to avoid intake of solar heated air. Please ensure that the intake and exhaust areas are on the same side of the building to avoid pressure differentials during windy conditions. Also, do not position intake near exhaust’s preheated air. If air conditioning is required to cool the shelter, discuss the situation with a qualified HVAC technician. Under average conditions, 12,000 BTUs will cool approximately 500 square feet to a comfortable level.
  Technalogix Ltd.                                                 TM-100 Modulator 10Electrical Service Recommendations  Technalogix recommends that a qualified, licensed local electrician be consulted for the required electrical service. We suggest local electricians because:  • The personnel knows the local codes • The personnel can be on site readily • You are apt to get better overall support if you give what business you can to local suppliers  Technalogix recommends that proper AC line conditioning and surge suppression be provided on the primary AC input to the power amplifier. All electrical service should be installed with your national electrical code in your area, any applicable provincial or state codes, and good engineering practice. Special consideration should be given to lightning protection of all systems in view of the vulnerability of most transmitter sites to lightning. Lightning arrestors are recommended in the service entrance. Straight and short grounds are recommended. The electrical serviced must be well grounded. Do not connect the unit to an open delta primary power supply, as voltage fluctuations could harm the unit. Branch your circuits. Do not allow your lights, your workbench plugs, and your transmitting or translating equipment off of one circuit breaker. Each transmitter should have its own circuit breaker, so a failure in one does not shut off the whole installation.  Antenna and Tower Recommendations  Your preliminary engineering workgroup should establish your antenna and tower requirements, both for receiving and transmitting antennas. Construction of sturdy, high quality antenna/tower systems will pay off in terms of coverage of your service area, the overall quality and saleability of your radiated signal, and reduced maintenance expenses. Technalogix provides complete turnkey antenna systems if needed.  Transmitting antennas can enhance or seriously impair the transmitter output. It is assumed that one has been selected prior to system installation, but the best-designed antenna system will function poorly if shortcuts and compromises are used during installation. Follow the manufacturer’s instructions exactly, along with any engineering data prepared for the site.
  Technalogix Ltd.                                                 TM-100 Modulator 11The selection, routing, and length of coaxial cable is extremely important in the installation. If there is a 3 dB line loss in the cable between your unit’s output and the transmitting antenna, a 500 watt unit will only deliver 250 watts to the antenna. Buy the best cable you can obtain, route it via the shortest way to the antenna, and keep it straight. Do not form it into sharp bends on its way. Do not use any more cable fittings for the installation than absolutely necessary. All cautions here apply equally to all coaxial cables in the system - input and output. The better known tower manufacturers offer complete technical and safety documentation with their towers. Be sure that you have this information as it regards wind loading, guying, etc. Be absolutely safe and certain about this aspect as human lives may be at stake.  Shelter Security  The FCC requires that the transmitter be secure from entry or control by unauthorized persons, and that any hazardous voltages or other dangers (including most tower bases) be protected by locks or fences as necessary to protect personnel and prevent unauthorized tampering or operation. Security of the building further implies that it be secure from wildlife. Use sturdy construction materials, including sheet metal if necessary. Holes around conduit, cable, and other similar entry points should be stuffed with steel wool and caulked to prevent entry of wildlife. Other features of security for your shelter may include its location with respect to the prevailing wind conditions. A location leeward of some natural topographical feature will prevent wind damage and snowdrifts. Check the soil runoff conditions that may slow or hasten wind or water erosion and other concerns that may be unique to your location.
  Technalogix Ltd.                                                 TM-100 Modulator 12Unpacking and Inspection  Check the outside of the container. Carefully open the container and remove the modulator. Retain all packing material that can be reassembled in the event that the equipment must be returned to the factory.   Exercise care in handling equipment during inspection to prevent damage due to rough or careless handling.   Visually inspect the enclosure of the modulator for damage that may have occurred during shipment. Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous packing material in connectors. Inspect all connectors for bent connector pins. If the equipment is damaged, a claim should be filed with the carrier once the extent of the damage is assessed. Technalogix cannot stress too strongly the importance of immediate careful inspection of the  equipment and subsequent immediate filing of the necessary claims against the carrier if necessary. If possible, inspect the equipment in the presence of the delivery person. If the equipment is damaged, the carrier is your first area of recourse. If the equipment is damaged and must be returned to the factory, phone for a return authorization. Claims for loss or damage may not be withheld from any payment to Technalogix, nor may any payment due be withheld pending the outcome thereof. Technalogix cannot guarantee the carrier’s performance.
  Technalogix Ltd.                                                 TM-100 Modulator 13Location and Function of Controls and Connectors  The following illustrations depict the location of the installation connectors when installing the power amplifier with a modulator or processor.  FRONT     BACK     Audio Deviation – Allows user to control extent of audio deviation.  Original factory setting at 25 KHz deviation using standard pre-emphasis curve.  Audio/Video Display Select - Provides a graphical representation of audio deviation and visual modulation levels on an LED bar graph.  The switch selects between audio deviation or visual modulation.      Video Modulation -- Allows user to control extent of video modulation.  Original factory setting at 87.5% video modulation with 1.0 Volt peak to peak baseband input video signal.  Frequency  Offset Select – Toggles between +10 KHz, 0KHz, and  –10 KHz frequency offset.  Aural Carrier Level  - Allows user to set aural carrier level relative to visual carrier level.  Modulator is factory tested at –10 dBc (decibels below visual carrier).
  Technalogix Ltd.                                                 TM-100 Modulator 14Output Select  – Selects the desired channel of operation.  If you require a lower channel than the one currently displayed, push the toggle switch down.  The channels will change one at a time as many times as you press the switch.  Holding the select switch in the up or down position will “scan” to the desired channel.  It is normal for the frequency lock LED to turn off during and for a few seconds after, changing channels.  The switch must be held up or down initially for three seconds. This helps to ensure that no accidental channel changes will occur.  Output Level – Sets visual carrier output level.    RF Out Test Point – Provides a sample of the RF output level which is 20 dB below the actual value.  RF test point is only a relative indicator of the actual RF output level and may vary.  All RF operating measurements should be made at the RF output of the unit.  RF Output -  Modulated Audio/ Video output capable of +60 dBmV levels using built in low distortion hybrid amplifiers.  RS-232 Ports – Set up for optional RS-232 control option.  Combined IF Input/ Output – 45.75 MHz visual carrier and 41.25 MHz audio carrier intermediate frequency signal loop.  Audio Input/ Ouput Loop – Available for baseband audio processing.  Video Input/ Output Loop - Available for baseband video processing.  Video In – Connection for 1.0 Volt peak to peak video source.   Balanced Baseband Audio In – Used to connect a 1 Volt peak to peak baseband audio signal.  For balanced input connection, connect 1 audio input lead to the left terminal on the connector and the other audio input lead to the right terminal.  For an unbalanced input connection, connect one audio input lead to the left terminal on the connector and the other audio input lead to the centre terminal.  Center terminal is chassis ground.
  Technalogix Ltd.                                                 TM-100 Modulator 155.0 OPERATING PROCEDURE  Preliminary Hook-up  1. Terminate modulator into a 50 ohm load before applying power.  2. Connect the power cord of the Technalogix TM-100 agile modulator to a proper electrical source as indicated on the back of the unit  3. Observe the front panel.  If power is applied and present, the red power LED will illuminate.  Also, all the elements of the displays behind the display readout window will illuminate momentarily as a display test.  4. Observe the numbers displayed behind the display readout window after the test.  They will indicate: • Microprocessor software version; • Internal option dipswitch settings; • RS-232 unit ID (if so equipped); and • Last tuned channel.  5. After a moment, the Lock Detect LED will illuminate.  Setup and Operation  A. Output level and channel selection; connecting monitor.  1. Connect a spectrum analyzer, or a field strength meter tuned to the frequency of the video RF carrier of the desired channel, to the RF OUTPUT jack on the rear panel of the unit.  Alternatively, connect a spectrum analyzer or a field strength meter to the –20dB TEST POINT on the front panel of the unit.  2. Select the desired output channel using the CHANNEL SELECT paddle switch on the front panel. • Hold the CHANNEL SELECT switch in the up- or down-position for approximately 3 seconds to activate the channel-select circuit; • Toggle the CHANNEL SELECT switch up to select a higher channel or toggle it down to select a lower channel.  The switch may be held in the up- or down-position for rapid channel switching.
  Technalogix Ltd.                                                 TM-100 Modulator 16 3. Observe the output on the spectrum analyzer, or the field strength meter.  If measuring from the rear panel RF OUTPUT jack, adjust the front panel OUTPUT LEVEL potentiometer for an output level between +55dBmV and +60dBmV.  If measuring from the front panel –20dB TEST POINT, ensure that the rear panel RF OUTPUT jack is terminated into a 50Ω load, then adjust the front panel OUTPUT LEVEL potentiometer for an output level between +35dBmV and +40dBmV.  4. If using a field strength meter, retune the meter to the frequency of the audio RF Carrier.  5. Still observing the output on the spectrum analyzer, or the field strength meter (now tuned to the frequency of the audio RF carrier), adjust the front panel AURAL CARRIER potentiometer for an output level 10-13dB lower than that at which the video RF Carrier is set.  6. Remove the spectrum analyzer, or field strength meter from the unit.  If available, connect a television/monitor to the front panel –20dB TEST POINT, apply power to the television/monitor and tune to the selected output channel of the Technalogix TM-100 modulator.  B. VIDEO input connection and adjustment.  1. Connect a 1.0VP-P video source to the VIDEO IN jack on the rear panel.  2. Adjust the front panel VIDEO MODULATION control for 87.5% modulation. • Set the front panel DISPLAY SELECT switch to VIDEO (down) position; • Observe front panel LED bargraph behind front panel display readout window. • First RED LED will begin illumination at approximately 87.5% modulation; or • Observe TV monitor for good visual image.
  Technalogix Ltd.                                                 TM-100 Modulator 17C. AUDIO input connection and adjustment – BASEBAND AUDIO  1. If your Technalogix TM-100 agile modulator is equipped with a 4.5MHz sub-carrier input option, ensure that the rear-panel AUDIO SELECT switch is in the BASEBAND position.    2. Connect a 1VP-P baseband audio signal to the rear panel baseband audio connector as follows: • For balanced input connection, connect one audio input lead to the left terminal on the connector and the other audio input lead to the right terminal. • For unbalanced input connection, connect one audio input lead to the left terminal on the connector and the other audio input lead to the center terminal. • Center terminal is chassis ground. • Insert the terminal into the connector on the rear panel of the TM-100.  3. Adjust the front panel AUDIO MODULATION control for 100% modulation. • Set the front panel DISPLAY SELECT switch to AUDIO (up) position. • Observe front panel LED bargraph behind front panel display readout window. • First RED LED will begin illumination at approximately 95% modulation; or • Adjust for ±25KHz deviation using a spectrum analyzer; or • Listen to the audio output from TV monitor and setting the loudness equal to that of an off-air channel carried on your system.  D. AUDIO input connection and adjustment – 4.5MHz Subcarrier input  1. Set the rear panel AUDIO SELECT switch in the 4.5 position.  2. Connect a modulated 4.5MHz subcarrier signal to the rear panel 4.5MHz input F-connector jack.  3. Inject a minimum +36dBmV (-12.75dBm) 4.5MHz RF carrier into the unit.  4. Using the setup in Step A.5., measure the audio RF carrier output level at the rear panel RF OUTPUT jack.  Level should be within ±2dB of the measurement taken in Step A.5.
  Technalogix Ltd.                                                 TM-100 Modulator 18Important  Technalogix power supplies are designed so that under certain power line or heat buildup conditions, the unit shuts off. An indicator would be no RF output, but the POWER LED remains on. If this occurs, unplug the power cord and wait two minutes before re-powering. Upon applying power, you should again have RF output. If not, or should the unit return to shutdown mode, please contact Technalogix for assistance. Technalogix highly recommends a 1.75 inch air circulation space between any rack mounted equipment.  Transmitter Hookup  1. Connect modulated video from TM-100 RF OUT to the Technalogix power amplifier.  2. Turn down RF level on TM-100 all the way.  3. Ensure that IF OUT is connected to IF IN on the TM-100 modulator using the loop F to F cable supplied.  4. Connect the transmitting antenna cable to the RF output connector on the power amplifier. It is recommended that a quality through line wattmeter be installed in this same line.  5. Verify that all signal and RF cables are connected properly.  6. After following proper installation procedures outlined in the power amplifier manual, plug the power amplifier’s power cords into an appropriate electrical outlet.   Output power should be adjusted with a sync and blanking signal only with the aural carrier removed. This is simply done by disconnecting one end of the audio carrier loop found on the back panel of the TM-100.
  Technalogix Ltd.                                                 TM-100 Modulator 196.0 PROBLEM TROUBLESHOOTING GUIDE  The guide below covers some typical symptoms, possible associated causes and suggested actions to follow before returning the unit for repair.  It is not meant to be all-inclusive. Symptom Possible Cause Suggested Action                                     No output Weak output  Unit tuned to output channel different from desired (this occurs particularly on the units which have green LED on the front panel to indicate “T” channels and channels above 99)  Input signal is too weak    IF loop cable on rear of unit loose/disconnected   Unit not plugged in or not getting power  Ensure selected output channel is desired channel    Ensure input signal strength is 1V  peak to peak  Check IF loop cable is securely attached  Check power cord and power source, fuse Excessive noise Spurious signals  Output level above rated maximum (most often occurs when changing from high-number channel to low-number channel, especially to the “T” channels)   IF level too high (most often occurs when routing IF through scrambler or other external device)     Input signal too strong or no input signal at all  Measure RF output from rear panel jack and adjust front panel OUTPUT LEVEL control as required  Measure normal IF output level for applied CW/unmodulated input carrier and ensure same level is returned to unit after external processing  Measure video level and pad to within specified input levels. Bad/noisy video  Aural carrier interfering with video carrier Measure Aural Carrier level and/or adjust AURAL CARRIER LEVEL control on front panel Channels do not change  Delay feature active Hold channel change switch in raised/lowered position for at least three seconds
  Technalogix Ltd.                                                 TM-100 Modulator 20 7.0 BILL OF MATERIALS, SCHEMATICS, AND PCB OVERLAYS    Agile Logic Board Bill of Materials  Last Revision: 09.12.00  Component Reference Quantity Identification Modifier Package C1 1 22pF    CAP250D C10 1 0.47uF    CAP100RP C11 1 10 uF    CAP100RP C12 1 22 uF    CAP100RP C13 1 22 uF    CAP100RP C14 1 22 uF    CAP100RP C15 1 22 uF    CAP100RP C16 1 0.01uF    CAP250D C17 1 0.01uF    CAP250D C18 1 47 uF    CAP100RP C19 1 47 uF    CAP100RP C2 1 22pF    CAP250D C20 1        CAP100RP C21 1 0.01uF    CAP250D C22 1 0.01uF    CAP250D C23 1 0.01uF    CAP250D C24 1 0.01uF    CAP250D C3 1 22 uF    CAP100RP C4 1 10 uF    CAP100RP C5 1 0.47uF    CAP100RP C6 1 0.47uF     CAP100RP C7 1 0.01uF    CAP250D C8 1 0.01uF    CAP250D C9 1 470 uF    CAP197R D1 1    RED T1 LED T1-W/HLD D2 1    T1 W/HLD LED   D3 1    RED T1 LED T1-W/HLD DS1 1    8 POS DPS8W JP1 1    4 POS HEADER JP-DUAL4 JP2 1    8 POS HEADER JP-DUAL8 JP3 1       JP-DUAL4
  Technalogix Ltd.                                                 TM-100 Modulator 21JP4 1     3PIN JP3IL JP5 1     3PIN JP3IL JP6 1    3PIN JP3IL JP7 1    3 POS  JP3IL JP8 1    3 IL JP3IL L1 1 6 T    COIL 60 L2 1 6 T    COIL 60 L3 1 6 T    COIL 60 L4 1 6 T    COIL 60 L5 1 6 T    COIL 60 P1 1     4 PIN SMB P10 1    10 POS DIPIL10 P11 1    4 PIN SMB P12 1    8 POS CONNIL8 P2 1    RT ANG F FCONN P3 1    12 POS CONN IL12 P4 1    12 POS CONN IL12 P5 1    ON DISPLAY BDS CONN IL19 P6 1    12 POS CONN IL12 P7 1    12 POS CONN IL12 P8 1    4 PIN SMB P9 1    10 PIN CONN10IL Q1 1    2222 TRANS2222 Q2 1    2907 TO18C QP1 1    4-2222A DIP14C R1 1 10 Mohm    RES1-8 R10 1 1 kOhm    RES1-8 R11 1 5 kOhm    POT1 R12 1 10 Kohm    RES1-8 R13 1 10 Kohm    RES1-8 R14 1 1 kOhm    RES1-8 R15 1 6.8 kOhm    RES1-8 R16 1 1 kOhm    RES1-8 R17 1 500 Ohm    POT1 R18 1 10 Kohm    RES1-8 R19 1 5.6 kOhm    RES1-8 R2 1 4.7 Ohm    RES1-8 R20 1 10 Kohm    RES1-8 R21 1 91 Ohm    RES1-8 R22 1 10 Ohm    RES1-8 R23 1 5 kOhm    POT1 R3 1 5 kOhm    POT1 R4 1 10 Kohm    RES1-8
  Technalogix Ltd.                                                 TM-100 Modulator 22R5 1 1 kOhm    RES1-8 R6 1 68 kOhm    RES1-8 R7 1 68 kOhm    RES1-8 R8 1 68 kOhm    RES1-8 R9 1 4.7 Ohm    RES1-8 RP1 1 10 Kohm    DIPIL11 RP2 1 10 Kohm    DIPIL11 RP3 1 10 Kohm    DIPIL11 RP4 1 150 Ohm    DIP IL8 RP5 1 150 Ohm    DIP IL8 SW1 1    PADDLE SW1 SW2 1    PADDLE SW1 SW3 1    ROCKER SW1 SW4 1    ROCKER SW1 U1 1    MC74HC165 DIP16C U2 1    IC34064 REGTO92 U3 1    68705C8 DIP40C U4 1    74H04 DIP14C U5 1    74H04 DIP14C U6 1    MC14499 DIP18C U7 1    DS232 DIP16C U8 1    X2402 DIP8C Y1 1 4MHz    XTAL
1133EEPROM MEMORY STORAGEMUTESPARES/DEMOD(360 MOD)VIDEO MODULATIONVIDEO OUTMODULATOR INPUTVIDEO IN370/370T VIDEO GAIN(360.361.362360 VIDEO MOD ADJ361/2 ALR LEVEL360 VIDEO MODULATIONNOTES:ON M/N UNITS W411808 DISPLAY BD. ONLY1. CUT THE ETCH CONNECTING PINS 6&9 ONTOP OF P5 ON TOP OF BOARD2. CUT THE ETCH CONNECTING PINS 7&11 ONP5 ON BOTTOM OF BOARD3. CONNECT PINS 1&6 OF P5 W/INSULATED WIRE ONBOTTOM OF BOARD4. CONNECT PINS 2&7 OF P5 W/INSULATED WIRE ONBOTTOM OF BOARD-20dB RF MONITOR90-FMONITOR IN360 BAR GRAPHDISPLAY(370 MOD) T CHANNEL(370 MOD) VHF/UHFTO JP2 P5-4TO P6.2 DEDOM INTERFACE+12VN/C  360 TEXTOVERLAY OPTION5K/370500R/360100K/361-2(360/370)(361/2)TDORDIRSTXRSRXLDOLDILD+12VTESTNORMINPUT CHOUTPUT CHINPUT MODEINPUT LD+30V+12V(362.SW33 W/R17)+5V+5V(DEMOD)W/R23CW/R23RSTXRSRX25 KHz12.5KHz+12VTO RP RJ11+5VMUTE-12VREFDATALDO12.5KHzOUT PLL ENCLOCK25KHz +12V+5V-12V+24V+12VIN PLL ENDATACLOCKLDOFFOUT LVLOUT LVLPROCESSOR  INPUTTO UP CONV.TO OUTPUT CONV.W/R17C20PLLI ENPLLO ENPLL ENDATA IOCLKPWRSBSELLED1LED0SPR41SPR51SPR61VINVRSTDATA IOCLK+5VN/COUT LVLOMIT FOR DEMODFP OUTPUTLEVEL ADJTO JP5.2TO JP5.3TO P4.2 RSRXTO P4.1 RSTXC5045.6 REAR PANELRJ11/RS232 INPUT+25VP/S LED+30V+12V-12VFROM P/SVIDEO TEXT OVERLAYP1P2P3P4P5P6P7P8JP3P1P2P3P4 P5P6P7P8U812345678 910111213141516U11QP112105313149867211234567891011121314151617181920P512345678 910111213141516JP2RP5RP4123456789101112131415161718U912345678 910111213141516U7NOT RESETNOT IRQNOT VPRSW1UPSW1DWNSW0UPSW0DWNPA3PA2S/LSHREGDATAIOCLKDSPENVRSTPLLIENPLLOENPLLENPWRGND ISTHROFF AIRSPR6ISPR5ISPR4ILED0LED1SBSELRDITDOLD0LDILDPD 5MUTE1VINTCAPOSC 2OSC 1VddU6S1S2S35V198673254RP3+C8INCOMOUTU3+C75VY1C4 C3123456910RP2RP15V5VC2L1+C9+5VQ1Q2+12VJP4+C12+C13+C14+C1+C11+C10+C6+C55VD4LOCK LEDP7P4P3P6U2FU2EU2DU2CU2BU2AU1FU1EU1DU1CU1BU1AP10R3+5VD3D2R171P1J1L3+5V+C181+12VJPRP111P9R111R1410k 40%+C200J2CON     +C191+C161+5VSW412VJP6        P100 P200J101                P12POWER ON LEDC22 C21L4+5VL5C23 C24+12VU4 U5+5V +5VP1P2P3P4P5P6P7P8JP1R11R2 R18R19R20R16R9R8 R7 R6R4R121R13R10R5R21R1R15R2213 21191143213219 841151310391112115437654321109876542117651132314324131323313512131411131011237363422216745212298121913719181716151413122122232425262728293031323334353611109876542111 111111Technalogix Ltd.#4, 8021 Edgar Industrial PlaceRed Deer, Alberta, Canada      T4P 3R3Agile LogicCDate: 09/11/00 Page: 1 of 1Rev ID1122334455667788991010A AB BC CD DE EF FG G
23
  Technalogix Ltd.                                                 TM-100 Modulator 25 Agile Output Amplifier Bill of Materials  Last Revision: 09.12.00  Component Reference Quantity Identification Modifier Package C1 1 0.1uF    1206 C2 1 0.1uF    1206 C3 1 2.7 pF    1206 C4 1 3-10pF VCAP CGKG27 C5 1 3-10pF VCAP CGKG27 C6 1 3-10pF VCAP CGKG27 C7 1 2.7 pF    1206 E1 1     E-COAX    E2 1 12 V    EPAD E3 1     E-COAX   E5 1 GND    EPAD I1 1       1206 L1 1        IND400 L2 1 10 nH    1210 L3 1 12 nH    1210 L4 1 12 nH    1210 L5 1 10 nH    1210 P1 1       FCONN-S U1 1     AMP6342
L3C4 C5L5L2C6L4C3 P1OUTPUTE3-20dB TEST1 952+U1C7E2+24VE1INPUTL1C2C1R1Technalogix Ltd.#4, 8021 Edgar Industrial PlaceRed Deer, Alberta, Canada    T4P 3R3Agile Output Amplifier BoardHDate: 09/11/00 Page: 1 of 1Rev ID11223344556677A AB BC CD DE EF FG GH HI IJ J24
  Technalogix Ltd.                                                 TM-100 Modulator 28 Audio Video Modulator Board Bill of Materials  Last Revision: 09.12.00  Component Reference Quantity Identification Modifier Package      C1 1 0.1uF    SMD1206 C10 1 0.1uF    SMD1206 C100 1 4.7uF    CAP100RP C101 1 100pF    SMD1206 C102 1 47uF    CAP100RP C103 1 0.1uF    SMD1206 C104 1 470pF    SMD1206 C105 1 0.1uF    SMD1206 C106 1 470uF    CAP200RP C107 1 0.1uF    SMD1206 C108 1 470uF    CAP200RP C109 1 0.0027uF    SMD1206 C11  1 0.1uF    SMD1206 C110 1 0.1uF    SMD1206 C111 1 NI    SMD1206 C112 1 470uF    CAP200RP C113 1 0.1uF    SMD1206 C114 1 0.1uF    SMD1206 C115 1 0.1uF    SMD1206 C116 1 0.1uF    SMD1206 C117 1 0.01uF    SMD1206 C118 1 18pF    SMD1206 C119 1 NI    SMD1206 C12  1 0.01uF    SMD1206 C120 1 0.1uF    SMD1206 C121 1 470uF    CAP200RP C122 1 0.01uF    SMD1206 C123 1 470uF    CAP200RP C124 1 10pF    SMD1206 C125 1 27pF    SMD1206 C126 1 82pF    SMD1206 C127 1 0.001uF    SMD1206 C128 1 0.01uF    SMD1206 C129 1 0.01uF    SMD1206 C13 1 0.1uF    SMD1206
  Technalogix Ltd.                                                 TM-100 Modulator 29C130 1 0.1uF    SMD1206 C131 1 NI    SMD1206 C132 1 0.1uF    SMD1206 C133 1 0.01uF    SMD1206 C134 1 0.01uF    SMD1206 C135 1 0.1uF    SMD1206 C136 1 0.1uF    SMD1206 C137 1 0.01uF    SMD1206 C138 1 0.1uF    SMD1206 C139 1 0.01uF    SMD1206 C14 1 0.001uF    SMD1206 C140 1 0.01uF    SMD1206 C141 1 0.01uF    SMD1206 C142 1 0.1uF    SMD1206 C143 1 12pF    SMD1206 C144 1 12pF    SMD1206 C145 1 3-10pF    CGKG27 C146 1 12pF    SMD1206 C147 1 12pF    SMD1206 C148 1 0.1uF    SMD1206 C149 1 0.01uF    SMD1206 C15  1 0.01uF    SMD1206 C150 1 0.1uF    SMD1206 C151 1 27pF    SMD1206 C152 1 56pF    SMD1206 C153 1 27pF    SMD1206 C154 1 0.01uF    SMD1206 C155 1 0.01uF    SMD1206 C156 1 0.01uF    SMD1206 C16 1 0.1uF    SMD1206 C17 1 22pF    SMD1206 C18 1 56pF    SMD1206 C19 1 10pF    SMD1206 C2 1 0.1uF    SMD1206 C20 1 0.001uF    SMD1206 C21 1 0.47uF    SMD1206 C22 1 22pF    SMD1206 C23 1 22pF    SMD1206 C24 1 4.5-20pF    CGKG27 C25 1 0.01uF    SMD1206 C26 1 0.001uF    SMD1206 C27 1 22pF    SMD1206 C28 1 4.7uF    CAP100RP C29 1 100pF    SMD1206
  Technalogix Ltd.                                                 TM-100 Modulator 30C3 1 4.7uF    CAP100RP C30 1 0.01uF    SMD1206 C31 1 0.1uF    SMD1206 C32 1 0.001uF    SMD1206 C33 1 0.01uF    SMD1206 C34 1 68pF    SMD1206 C35 1 100pF    SMD1206 C36 1 100pF    SMD1206 C37 1 68pF    SMD1206 C38 1 470uF    CAP200RP C39 1 0.01uF    SMD1206 C4 1 0.1uF    SMD1206 C40 1 0.01uF    SMD1206 C41 1 0.1uF    SMD1206 C42 1 0.01uF    SMD1206 C43 1 0.01uF    SMD1206 C44 1 0.1uF    SMD1206 C45 1 470uF 25V CAP200RP C46 1 1000uF    CAP300RP C5 1 4.7uF    CAP100RP C6 1 0.1uF    SMD1206 C7 1 0.001uF    SMD1206 C8 1 470uF    CAP200RP C9 1 47pF    SMD1206 D1 1 5236    SOT23 D10 1 3800    SOT23 D100 1 2800    SOT23 D101 1 2800    SOT23 D11 1 3800    SOT23 D2 1 2800    SOT23 D3 1 2800    SOT23 D6 1 MMBV105GL    SOT23 D7 1 10 V    SOT23 D8 1 4.7V    SOT23 D9 1 3800    SOT23 F1 1      SIP5L F100 1      FILTER2219 F101 1      SF28S J1 1 NI    SMD1206 JP1 1 NI    SMD1206 JP2 1 0    SMD1206 JP3 1 NI    SMD1206 JP4 1 NI    SMD1206
  Technalogix Ltd.                                                 TM-100 Modulator 31JP5 1 0    SMD1206 L1 1 10.5 T,26GA    COIL L100 1 12.5T 22GA    COIL L101 1 0.47uH    SMD1812 L102 1 0.47uH    SMD1812 L103 1 12.5T 22GA    COIL-S L104 1 12.5T 22GA    COIL-S L105 1 0.47uH    SMD1812 L106 1 0.47uH    SMD1812 L107 1 0.47uH    SMD1812 L15 1 0.47uH    IND400 L2 1 0.33uH    SMD1812 L3 1 0.33uH    SMD1812 L4 1 0.33uH    SMD1812 L5 1 0.47uH    SMD1812 MX100 1      MIXER P1 1      FCONN-S P100 1      FCONN-S P101 1      RTARCA P102 1      RTARCA P103 1      FCONN-S P2 1      CONN10IL P7 1      CONHDR6 P8 1      CONHDR6 Q1 1 2369    SOT23 Q100 1 2222    SOT23 Q101 1 2907    SOT23 Q102 1 2222    SOT23 Q103 1 2222    SOT23 Q104 1 2907    SOT23 Q105 1 2222    SOT23 Q106 1 2222    SOT23 Q107 1 2222    SOT23 Q108 1      MRF559B2 Q109 1      MRF559B2 Q110 1      MRF559B2 Q2 1 2369    SOT23 R1 1 300kohm    SMD1206 R10 1 220kohm    SMD1206 R100 1 75ohm    R1206A R101 1 22kohm    SMD1206 R102 1 270ohm    SMD1206 R103 1 620ohm    SMD1206 R104 1 2kohm    SMD1206
  Technalogix Ltd.                                                 TM-100 Modulator 32R105 1 360ohm    SMD1206 R106 1 2kohm    SMD1206 R107 1 51ohm    SMD1206 R108 1 330ohm    SMD1206 R109 1 3.6kohm    SMD1206 R11 1 100ohm    SMD1206 R110 1 6.8kohm    SMD1206 R111 1 680kohm    SMD1206 R112 1 1kohm    SMD1206 R113 1 910ohm    SMD1206 R114 1 22ohm    SMD1206 R115 1 330ohm    SMD1206 R116 1 1.5kohm    SMD1206 R117 1 560ohm    SMD1206 R118 1 1kohm    SMD1206 R119 1 330ohm    SMD1206 R12 1 75kohm    SMD1206 R120 1 1kohm POTENTIOMETER ST53YJ R121 1 560ohm    SMD1206 R122 1 1.5kohm    SMD1206 R123 1 470kohm    SMD1206 R124 1 51ohm    SMD1206 R125 1 10kohm POTENTIOMETER ST53YJ R126 1 1kohm    SMD1206 R127 1 1kohm    SMD1206 R128 1 NI    SMD1206 R129 1 360ohm    SMD1206 R13 1 1kohm    SMD1206 R130 1 10kohm POTENTIOMETER ST53YJ R131 1 180ohm    SMD1206 R132 1 51ohm    SMD1206 R133 1 150ohm    SMD1206 R134 1 22ohm    SMD1206 R135 1 10kohm    SMD1206 R136 1 10kohm    SMD1206 R137 1 1.5kohm    SMD1206 R138 1 1kohm    SMD1206 R139 1 10kohm    SMD1206 R14 1 470kohm    SMD1206 R140 1 20kohm 1% SMD1206 R141 1 27ohm    SMD1206 R142 1 36ohms    SMD1206 R143 1 27ohm    SMD1206 R144 1 1kohm    SMD1206
  Technalogix Ltd.                                                 TM-100 Modulator 33R145 1 4.7ohm    SMD1206 R146 1 82ohm    SMD1206 R147 1 2kohm    SMD1206 R148 1 220ohm    SMD1206 R149 1 75ohm    SMD1206 R15 1 10kohm POTENTIOMETER ST53YJ R150 1 1kohm    SMD1206 R151 1 18ohm    SMD1206 R152 1 1kohm    SMD1206 R153 1 1kohm    SMD1206 R154 1 2kohm    SMD1206 R155 1 4.7ohm    SMD1206 R156 1 82ohm    SMD1206 R157 1 220ohm    SMD1206 R158 1 75ohm    SMD1206 R159 1 4.7ohm    SMD1206 R16 1 100ohm    SMD1206 R160 1 91ohm    SMD1206 R161 1 4.7ohm    SMD1206 R162 1 4.7ohm    SMD1206 R163 1 75ohm    SMD1206 R164 1 4.7ohm    SMD1206 R165 1 1kohm    SMD1206 R166 1 2kohm    SMD1206 R167 1 4.7ohm    SMD1206 R168 1 82ohm    SMD1206 R169 1 75ohm    SMD1206 R17 1 1kohm    SMD1206 R170 1 220ohm    SMD1206 R171 1 NI    SMD1206 R172 1 NI    SMD1206 R18 1 270ohm    SMD1206 R19 1 10kohm    SMD1206 R2 1 150kohm    SMD1206 R20 1 560ohm    SMD1206 R21 1 10kohm    SMD1206 R22 1 1kohm    SMD1206 R23 1 390ohm    SMD1206 R24 1 100kohm    SMD1206 R25 1 220kohm    SMD1206 R26 1 1Mohm    SMD1206 R27 1 2kohm    SMD1206 R28 1 68ohm    RES2010A R29 1 220ohm 1/2 WATT RES2010A
  Technalogix Ltd.                                                 TM-100 Modulator 34R3 1 300kohm    SMD1206 R30 1 75ohm    SMD1206 R31 1 1kohm    SMD1206 R32 1 1kohm    SMD1206 R33 1 2kohm    SMD1206 R34 1 1kohm    SMD1206 R35 1 4.7kohm    SMD1206 R36 1 2kohm    SMD1206 R37 1 1kohm    SMD1206 R38 1 430ohm    SMD1206 R39 1 27ohm    SMD1206 R4 1 150kohm    SMD1206 R40 1 430ohm    SMD1206 R5 1 1kohm    SMD1206 R7 1 4.7kohm    SMD1206 R8 1 10kohm    SMD1206 R9 1 10kohm    SMD1206 TB1 1      TERBLK TP100 1 0    SMD1206 TP101 1 0    SMD1206 U1  1 LF353    DIP8SM U100 1 NE592D    DIP8SM U101 1 2090    DIP16SM U102 1 LM1881    DIP8SM U103 1 LM358    DIP8SM U2 1 145106    145106 U4 1 501    FPT-08-M01 Y1  1      XTL49 Y100 1 45.75Mhz    XTL49
AUDIO/INPUTFROM LOGIC BOARD P8TO LOGIC BOARD P11VIDEO OUTP103P2:4 P2:3 P2:1L2L200P1P2P3P4 P5P6P7P8U1138165724U100P101P1P2 P3P4GROUP DELAYF100P1P2P3P4 P5P6P7P8U102P1P2P3P4P5P6P7P8 P9P10P11P12P13P14P15P16U101P1P2P3P4P5P6P7P8P9 P10P11P12P13P14P15P16P17P18U10L15+12VC47 D1C4C25647+U1:B+C3P2:5TB1 P2:6 C6+C5 +12V+C83281+U1:AC9C7J1STEREO+C46+12VC13C21C25C22C23C24Y1JP5JP4JP2JP1JP3C27C26+12VD8C28D7+12VAC11D2D3C1032841+U103:A+12VP2:9C12R15C14D6L1C15+12VC16+C38Q3C17C18C115D101D100C11656847+U103:B+12VP2:10C117R125TP100Q102+12VC113+C112 Q103Q101Q104C114R120+12V+12V+C45Q106C118+12VC129+C106C107C109+C108C111+12VC110+12VQ100P100 P102 +C100+C102C130C101C105C104C103+12VC29C30 C32C31P8:1P8:2P2:7+12VC41 C40C39D11D9D10C43P2:8 L5 C42P1+12V+C44+C156P2:2P7:5TP1C33C20Q2C19L3 L4TP2C35C34 C36 C37C123 L100C124C128C125C126y100Q107C127C12212VC120Q5+C121R130MX212345678TP1C119C131C132Q6C133L101C136C134C135 12VF1015 1C142C13912VC137C140C141C138Q7L102C143C145L103 L104C146C144C147C148 Q4C149L105C150C154C155 12VC151 C152 C153L106 L107R5R4R2R1 R23R10R8 R9R3R12R7R11R24 R26R25R13R18R27R29R28R14R17R16R19R20R21R22R123R126R124R118R115R114R116R119R117 R121R122R134R133R127R107R106R105R113R112R104R111R110R109R108R100R101 R102R103R37 R36 R35R32R33R34R31R38 R39R40R30R42R135R136R137 R140R138R139R132R131R129R128R141R142R143R147R144R145R146R148R150R151R152R149R159R156R155R158R153R154R157R160R161 R162R163R164R166R165R170R167R168R169Technalogix Ltd.#4, 8021 Edgar Industrial PlaceRed Deer, Alberta, Canada T4P 3R3Audio Video Modulator BoardEDate: 09/11/00 Page: 1 of 1Rev ID1122334455667788991010A AB BC CD DE EF FG G
  Technalogix Ltd.                                                 TM-100 Modulator 37Digital Up converter Bill of Materials  Last Revision: 09.12.00  Component Reference Quantity Identification Modifier Package C1 1 0.1uF    1206 C101 1 100 Pf    1206 C102 1 0.1uF    1206 C103 1 100uF 25V CAP100RP C104 1 0.47uF    1812 C105 1 0.1uF    1206 C106 1 0.22uF    1206 C107 1 100 Pf    1206 C108 1 1pF    1206 C109 1 100 Pf    1206 C11 1 0.1uF    1206 C110 1 100 Pf    1206 C111 1 1pF    1206 C112 1 1pF    1206 C113 1 1pF    1206 C114 1 1pF    1206 C115 1 0.47uF    1812 C116 1 0.1uF    1206 C116A 1 100uF 25V CAP100RP C117 1 0.1uF    1206 C118 1 0.1uF    1206 C119 1 0.1uF    1206 C12 1 0.01uF    1206 C120 1 100 Pf    1206 C126 1 0.1uF    1206 C127 1 0.1uF    1206 C128 1 100 Pf    1206 C129 1 0.1uF    1206 C13 1 0.1uF    1206 C130 1 2.2pF    1206 C131 1 100 Pf    1206 C132 1 0.1uF    1206 C133 1 0.47uF    1206 C134 1 100uF 25V CAP100RP C135 1 10 Pf    1206 C136 1 10 Pf    1206 C137 1 10 Pf    1206 C138 1 10 Pf    1206
  Technalogix Ltd.                                                 TM-100 Modulator 38C139 1 10 Pf    1206 C14 1 0.01uF    1206 C140 1 10 Pf    1206 C141 1    NI 1206 C15 1 0.1uF    1206 C2 1 0.01uF    1206 C201 1    NI CGKG27 C204 1 0.1uF    1206 C205 1 0.1uF    1206 C206 1 100 Pf    1206 C207 1 0.1uF    1206 C208 1 2.2pF    1206 C209 1 0.1uF    1206 C21 1 0.1uF    1206 C210 1 0.1uF    1206 C3 1 0.01uF    1206 C300 1 0.1uF    1206 C301 1 100 Pf    1206 C303 1 470 uF 25 V CAP200RP C4 1 0.01uF    1206 C5 1 0.1uF    1206 D1   1 3800    SOT-23 D100 1 9.1V DIODEZ DO214AC D101 1 9V 914 SOT-23 D102 1 4.7V    SOT-23 D103 1 10 V DIODEZ DO214AC D2 1 3800    SOT-23 D3 1 3800    SOT-23 F2 1      F-LP-TOKO F4 1      F-LP-TOKO FT200 1      FIL-TOKO J1 1 N/A    THRU-HOLE J10 1 N/A    THRU-HOLE J2 1 N/A    THRU-HOLE J3 1 N/A    THRU-HOLE J4 1 N/A    THRU-HOLE J5 1 N/A    THRU-HOLE J6 1 N/A    THRU-HOLE J7 1 N/A    THRU-HOLE J8 1 N/A    THRU-HOLE J9 1 N/A    THRU-HOLE L1 1 0.47uH    1812 L104 1 10nH    1812 L107 1 0.22uH    1210
  Technalogix Ltd.                                                 TM-100 Modulator 39L108 1 0.22uH    1210 L109 1 0.22uH    1210 L5 1 0.47uH    1812 L6 1 0.47uH    1812 M1 1    MIXER-RF2   P1 1 N/A    FCONN-S P2 1 N/A    FCONN-S R1   1 1k Ohm  1206 R101 1 1k Ohm  1206 R102 1 910 Ohm    1206 R103 1 910 Ohm    1206 R104 1 0    1206 R105 1 47 kOhm    1206 R106 1 220 Ohm 1/2 WATT  RES2010A R108 1 43 Ohm 1/2 WATTS RES2010A R109 1 220 Ohm 1/2 WATT  RES2010A R111 1 33 Ohm  1206 R112 1 180 Ohm    1206 R113 1 180 Ohm    1206 R114 1 220 Ohm 1/2 WATT  RES2010A R115 1 75 Ohm  1206 R116 1 10 Ohm  1206 R117 1 36 Ohm  1206 R118 1 10 Ohm  1206 R119 1 75 Ohm  1206 R120 1 110 Ohm 1 WATT RES2010A R121 1 4.7 Ohm    1206 R122 1 91 Ohm  1206 R123 1 4.7 Ohm    1206 R14 1 36 Ohm  1206 R15 1 62 Ohm  1206 R16 1 36 Ohm  1206 R17 1 1k Ohm  1206 R18 1 2k Ohm  1206 R19 1 75 Ohm  1206 R2 1 1k Ohm  1206 R20 1 8.2 Ohm    1206 R200 1 300 Ohm    1206 R201 1 18 Ohm  1206 R202 1 300 Ohm    1206 R203 1 100 Ohm    1206 R204 1 110 Ohm 1 WATT RES2010A R205 1 4.7 Ohm    1206 R206 1 75 Ohm  1206
  Technalogix Ltd.                                                 TM-100 Modulator 40R207 1 4.7 Ohm    1206 R21 1 82 Ohm  1206 R22 1 220 Ohm    1206 R23 1 100 Ohm    1206 R24 1 4.7 Ohm    1206 R25 1 100 Ohm    1206 R3 1 2k Ohm  1206 R4 1 4.7k Ohm    1206 R5 1 2k Ohm  1206 R6 1 1k Ohm  1206 U100 1     145200 TSSOP20 U101 1    ERA5 WW107 U102 1    ERA5 WW107 U2  1    RF559B2   U200 1    ERA5 WW107 VC01 1      MINI14SL
IF INLOCK DETECT TO MPUC300 C301 C21+C303+12V    +12V        D3D2D1C5C2                C1P1      L1C4        +12V+12VL5 C3C12C11ENABLE INJ6CLOCK INJ5DATA INJ4250 KHZ REF FROM ON CONVERTERJ3J2C129C128C38+1423U102C126C125L103C124L102C123L101C122C121L100+U101+C116AC141L107C135C136C139 C140L109C137 C138L108C131C132C133+C134D10212VD101C104C11012VD100+C103 C101 C102C108C107C106C105D10312VC109 C115 C116C117C119 C12012VC118C111C112C113C114L104C130IF OUTP2942 MHZC208C205+12VC210C209C207C206+1423U200C204C201C15L6C14+1423U2IF MIXERMIX 1LOFIL 200P1P2P3P4P5P6P7P8P9P10P11P12P13P14P15P16P17P18P19P20M145200U100VCD1U6R4R5R2R3R1R15R1900R6R14 R16R1800R17R120R116R119R109R101R106R105R104R103R102R108R111R112 R113R114 R115R117R118R121R123R122R206R205 R207R204R203R201R202R200R25R23R24R22R21R20Technalogix Ltd.#4, 8021 Edgar Industrial PlaceRed Deer, Alberta, Canada    T4P 3R3Digital Up ConverterA 412-0885-000Date: 09/11/00 Page: 1 of 1Rev ID1122334455667788991010A AB BC CD DE EF FG G
  Technalogix Ltd.                                                 TM-100 Modulator 43750 MHz Down Converter Bill of Materials  Last Revision: 09.13.00  Component Reference Quantity Identification Modifier Package C1 1 27 pF    1206 C10 1 100 pF    1206 C100 1 2.2 pF    1206 C101 1 2.2 pF    1206 C102 1    NI 1206 C11 1 0.1 uF    1206 C12 1 0.47 uF    1812 C13 1 100 uF 25 V CAP100RP C14 1    NI 1206 C15 1 10 pF    1206 C16 1 10 pF    1206 C17 1 10 pF    1206 C18 1 10 pF    1206 C19 1 10 pF    1206 C2 1 27 pF    1206 C20 1 10 pF    1206 C200 1    NI 1206 C205 1 2.7 pF    1206 C206 1 3-10 pF    CGKG27 C207 1 3-10 pF    CGKG27 C208 1 3-10 pF    CGKG27 C209 1 2.7 pF    1206 C21 1 0.1 uF    1206 C210 1 0.1 uF    1206 C211 1 0.1 uF    1206 C212 1 0.1 uF    1206 C213 1 100 pF    1206 C214 1 1 pF    1206 C215 1 10 pF    1206 C22 1 0.22 uF    1206 C23 1 100 pF    1206 C24 1 1 pF    1206 C25 1 100 pF    1206 C26 1 0.1 uF    1206 C27 1 100 uF 25 V CAP100RP C28 1 0.1 uF    1206 C29 1 0.1 uF    1206 C3 1 4.5-20 pF    CGKG27
  Technalogix Ltd.                                                 TM-100 Modulator 44C30 1 0.1 uF    1206 C301 1 0.1 uF    1206 C302 1 100 pF    1206 C303 1 470 uF 35 WV CAP275RP650 C304 1 0.1 uF    1206 C31 1      1206 C33 1 1 pF    1206 C34 1 1 pF    1206 C35 1 1 pF    1206 C36 1 1 pF    1206 C37 1 0.1 uF    1206 C38 1 0.1 uF    1206 C39 1    NI 1206 C4 1 0.47 uF    1812 C40 1    NI 1206 C41 1    NI 1206 C44 1 0.1 uF    1206 C45 1 0.1 uF    1206 C46 1 100 pF    1206 C5 1 100 pF    1206 C6 1 0.1 uF    1206 C7 1 0.47 uF    1812 C8 1 100 uF 25 V CAP100RP C9 1 100 pF    1206 D1 1 9 V D914 SOT23 D2 1 9.1 V DIODEZ D0214AC D3 1 9 V    SOT23 D4 1  DIODEZ D0214AC FT100 1      FIL-TOKO J1 1      THRU-HOLE J2 1      THRU-HOLE J3 1      THRU-HOLE J4 1      THRU-HOLE J5 1      THRU-HOLE J6 1      THRU-HOLE J7 1      THRU-HOLE J8 1      THRU-HOLE J9 1      THRU-HOLE L1 1 0.22 uH    1210 L100 1 10 nH    1210 L2 1 0.22 uH    1210 L200 1 10 nH    1210 L201 1 12 nH    1210
  Technalogix Ltd.                                                 TM-100 Modulator 45L202 1 12 nH    1210 L203 1 10 nH    1210 L204 1 10 nH    1210 L3 1 0.22 uH    1210 L4 1 10 nH    1210 M1 1    PULSAR MIXER-RF2 OSC1 1    MA06 MINI14SL P1 1      FCONN-S P2 1      FCONN-S R10 1 180 Ohm    1206 R100 1 33 Ohm    1206 R101 1 51 Ohm    1206 R102 1 4.7 Ohm    1206 R103 1 91 Ohm    1206 R104 1 4.7 Ohm    1206 R11 1 33 Ohm    1206 R12 1 180 Ohm    1206 R13 1 220 Ohm 1/2 WATT RES2010A R14 1 0 Ohm    1206 R15 1 75 Ohm    1206 R16 1 10 Ohm    1206 R17 1 33 Ohm    1206 R18 1    NI 1206 R19 1    NI 1206 R2 1 10 kOhm    1206 R20 1 4.7 Ohm    1206 R200 1    NI 1206 R201 1    NI 1206 R202 1 0 Ohm    1206 R203 1    NI 1206 R204 1 0 Ohm    1206 R207 1 0 Ohm    1206 R208 1 110 Ohm 1 WATT RES2010A R209 1 0 Ohm    1206 R21 1 110 Ohm 1 WATT RES2010A R210 1    NI 1206 R211 1 0 Ohm    1206 R22 1 75 Ohm    1206 R3 1 220 Ohm 1/2 WATT RES2010A R4 1 47 kOhm    1206 R5 1      RES2010A R6 1 910 Ohm    1206 R7 1 910 Ohm    1206 R8 1 0 Ohm    1206
  Technalogix Ltd.                                                 TM-100 Modulator 46R9 1 43 Ohm 1/2 WATT RES2010A U1 1    145200 TSSOP20 U2 1    ERA3 WW107 U201 1    ERA5 WW107 U3 1    ERA5 WW107 Y1 1 4000 MHz    XTL49
P3LOCK DETECT TO MPULORFRF OUT  L204C214C21112VC215C213C212C210C209L203L202C208C207C206L201L200C205C4212VC47C48C43C200C39C102P1      C100 C101L100C38C45C46L4C33C34C35C36C37C41C40C2912VC30C31C28C26C25C2712VD3C21C22C23 C24C5C6C7+C8 D29.1V12VC9C3C4D1        C2 C1Y14.00MHZ12VD4ZENER+C101uF C111uF C121uF C131uFRFOUT-J6CLK-J4  L2C141uFC151uFDI-J3   L1C161uFC171uFC181uF C191uFL3EN-J5   1234567891011121314151617181920U1U3ERA U4ERA5U4 U201FILTERU16VCCGNDVIN RFOUTOSCR211R210R209R208R207R204R206R205R212R212R202R203R201R20R18R19R200R103R104R102R101R100R21R16R22R17R15R14R13R12R10R11R8R6R7 R1R4R3R2 R5R9Technalogix Ltd.#4, 8021 Edger Industrial PlaceRed Deer, Alberta, Canada  T4P 3R3750MHz Down ConverterBDate: 9/11/2000 Page: 1 of 1Rev ID1122334455667788991010A AB BC CD DE EF FG G
  Technalogix Ltd.                                                 TM-100 Modulator 49Power Supply Bill of Materials  Last Revision: 09.12.00  Component Reference Quantity Identification Modifier Package C1 1 4700 35 V CAP400RPHORZ C10 1 0.1 uF    CAP250 C11 1 0.1 uF    CAP250 C12 1 0.1 uF    CAP250 C13 1 0.1 uF    CAP250 C14 1 1000 50 V CAP275RP650 C15 1 0.1 uF    CAP250 C16 1 4700 16 VDC CAP275RP650 C17 1 1000 50 V CAP275RP650 C18 1 0.1 uF    CAP250 C19 1 0.1 uF    CAP250 C2 1 4700 35 V CAP400RPHORZ C3 1 0.1 uF    CAP250 C4 1 0.1 uF    CAP250 C5 1 0.1 uF    CAP250 C6 1 0.1 uF    CAP250 C7 1 2200 35 V CAP275RP650 C8 1 0.1 uF    CAP250 C9 1 10000 25 VDC CAP400RPHORZ P1 1      CONHDR6 P2 1      CONHDR6 P3 1      CONHDR6 P4 1      CONHDR6 P5 1      CONHDR6 P6 1      CONHDR6 P7 1      CONHDR8 R1 1 2 kOhm    RES400 R2 1 240 Ohm    RES400 R4 1 5.6 kOhm    RES400 U1 1      BRIDGE U2 1      RBRDG-RECT-403M U3 1    LM317 T0-220-AB U4 1    7824 T0-220-AB U5 1    7812 T0-220-AB U6 1    7805 T0-220-AB U7 1      DIP6-2
432143214321GND+24VGND+12V+5V+30V123456P2123456P3123456P4123456P5123456P6C13C11+C17 C31IN2COM3OUT+30VU3LM317C6+C14C19 C18+C2 C81IN2COM3OUT +12VU57812C10+C9C1212345678P7+C16C151IN2COM3OUT +5VU67805654321P1+C7C51IN2COM3OUT +24VU47824+C1C4U7U2U1R2R4R1Technalogix Ltd.#4, 8021 Edgar Industrial PlaceRed Deer, Alberta, Canada      T4P 3R3Power Supply BoardDDate: 09/11/00 Page: 1 of 1Rev ID11223344556677A AB BC CD DE EF FG GH HI IJ J
Thank youfor choosingTechnalogix Ltd.

Navigation menu