Symbol Technologies CCRF5020 802.11b RF Port User Manual Hardware Installation Guide

Symbol Technologies Inc 802.11b RF Port Hardware Installation Guide

Hardware Installation Guide

MobiusModel CCRF-5020-10-WWIEEE 802.11b Access PortHardware Installation GuidePre-Release72-55582-01May 20, 2002
CopyrightCopyright © 2002 by Symbol Technologies, Inc. All rights reserved. No part of this publication maybe modified or adapted in any way, for any purposes without permission in writing from SymbolTechnologies, Inc. (Symbol). The material in this manual is subject to change without notice. Symbolreserves the right to make changes to any product to improve reliability, function, or design. Nolicense is granted, either expressly or by implication, estoppels, or otherwise under any SymbolTechnologies, Inc., intellectual property rights. An implied license only exists for equipment, circuitsand subsystems contained in Symbol products. Symbol, the Symbol logo and Spectrum24 areregistered trademarks of Symbol Technologies, Inc.PatentsThis product is covered by one or more of the following U.S. and foreign Patents:U.S. Patent No.4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095;4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717;5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520;5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232;5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553;5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498;5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148;5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198;5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042;5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469;5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680;5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139;5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043;5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287;5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078;5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478;5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285;6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297;6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620;6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; D305,885; D341,584;D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077;D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159;D431,562Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269(Japan);European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/0938; Italy1,138,713
Symbol Technologies, Inc.One Symbol Plaza Holtsville, N.Y. 11742-1300Telephone: (800)SCAN234, (516) 738-2400Telex: 6711519http://www.symbol.com
About this DocumentAudienceThis guide is intended for the technician responsible for installing the MobiusWireless LAN Switch. It is also assumed that the technician is familiar withEthernet LAN-based networking concepts.PurposeThe purpose of this document is to provide specifications, features andguidelines for the installer to use during installation. This document does notgive site-specific installation instructions. Refer to site-specific documentation,derived from site survey and site network analysis, for detailed installations.Document ConventionsBefore working on any equipment, be aware of the hazards associated with itsinstallation and use. Also, become familiar with standard practices for preventingaccidents. Note:  Indicates tips, hints and special requirements that the reader shouldtake note.Caution!  Indicates that care is required. Disregarding cautions can resultin data loss or equipment damage.WARNING!  Indicates a potentially dangerous condition or procedure thatonly Symbol-trained personnel should attempt to correct orperform.
WarningsWARNING! Only trained and qualified personnel are allowed to install thisequipment.WARNING! Read all installation instructions and site survey reports, andverify correct equipment installation before connecting the system toits power source.WARNING! Remove any jewelry (rings, watches, necklaces, etc.) whileinstalling this equipment.WARNING! Verify that any device connected to this unit is properly wiredand grounded.WARNING! Verify connecting power circuits have appropriate overloadprotection.WARNING! Attached only approved cables to this device.WARNING! Verify adequate ventilation around the device, and thatambient temperatures meet equipment operation specifications.WARNING! Verify uninterruptible power sources, if equipment is carryingemergency traffic.WARNING! Install unit in plenum-rated ceilings only.WARNING! Do not include the surface assembly for plenum-rated ceilingmounting.
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 6 of 13IntroductionThe Mobius Access Port provides area coverage to 802.11b wireless networkdevices. The Access Port includes different installing options, allowing bestplacement for the operate with its optimum range.The standard mounting base allows the unit to get secured to most surfaces bythe use of two screws. The ceiling mounting option allows the unit to attach toceiling by a single screwThe Access Port receives power and transfers data through the same (CAT-5)cable.Technical SpecificationsOperating Voltage 48 vdc (typical)36 vdc to 57 vdc (range)Operating Current 10 mA to 150 mAPeak Current 250 mAOperating Temperature -20°C to 50°COperating Humidity 5% to 95%Storage Temperature -40° to 70°CAltitude 2.4 km (operating max)4.6 km (storage max)
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 7 of 13Drop .8 meter (to concrete)MTBF 27,000 hrsElectrostatic Discharge +/-15 kV (air discharge)+/-8 kV (contact discharge)+/-2 kV (pin discharge)
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 8 of 13Preparing for Site InstallationVerify that the contents of the box include the following:•  Access Port Assembly• Surface-Mount Assembly• Mounting Anchors• Mounting Screws• Surface-Mount Badge• Surface-Mount Cover•  Surface-Mount Light Pipe Screw• Ceiling-Mount Grommet• Ceiling-Mount Badge•  Ceiling-Mount Light Pipe Screw• Installation GuideReview Site survey and network analysis reports to determine the method forAccess Port installation.Surface MountingMobius Access Ports mount to any surface, using the surface mounting screws.Use the mounting mask to determine the proper placement for the unit and themounting screws.
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 9 of 13
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 10 of 13Ceiling MountingSome installations require Access Port mounting above the ceiling tile. The typeof installation hides the unit and cable away from visual access. Note:  Use this installation in plenum-rated ceiling configurations. Verify thatthe attaching Ethernet cable is also plenum rated.Caution!  Use care when pulling cables attached to a mounted unit.
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 11 of 13Power/Data (RJ-45) ConnectionThe Access Port receives power from the Ethernet cable. It supports thefollowing Symbol-branded Power-Over-Ethernet devices.Mobius 1-Port Power Port (Model )Mobius 12-Port Power Port (Model ) Note:  Review installation plans to determine device placement and cablerouting.
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 12 of 13Customer SupportSymbol Technologies provides its customers with prompt and accuratecustomer support. Use the Symbol Support Center as the primary contact forany technical problem, question or support issue involving Symbol products.If the Symbol Customer Support specialists cannot solve a problem,access to all technical disciplines within Symbol becomes available forfurther assistance and support. Symbol Customer Support responds to calls byemail, telephone or fax within the time limits set forth in individual contractualagreements.When contacting Symbol Customer Support, please provide thefollowing information:•  serial number of unit•  model number or product name•  software type and version number.North American ContactsInside North America, contact Symbol by:• Symbol Technologies, Inc.One Symbol PlazaHoltsville, New York 11742-1300Telephone: 1-516-738-2400/1-800-SCAN 234Fax: 1-516-738-5990• Symbol Support Centertelephone: 1-800-653-5350fax: (516) 563-5410Email: support@symbol.com
Mobius Model 5020 Access Port Hardware Installation GuideJun/19/2002Page 13 of 13International ContactsOutside North America, contact Symbol by:• Symbol Technologies, Inc.Symbol PlaceWinnersh Triangle, Berkshire, RG41 5TPUnited Kingdom0800-328-2424 (Inside UK)+44 118 945 7529 (Outside UK)Symbol Developer Program Web Sitehttp://software.symbol.com/devzoneSymbol Knowledge Basehttp://kb.symbol.com/register.aspAdditional InformationObtain additional information by contacting Symbol at:•  1-800-722-6234, inside North America•  +1-516-738-5200, in/outside North America•  http://www.symbol.com/