3567910111214Safety PrecautionsProduct ComponentsOptional AccessoriesProduct Description Product DimensionCables and Connectors Power ConnectionRS485 ConnectionDigital Input Connection Contents-2-14161718192021Digital Input Connection WiegandInput/OutputWall-mount Bracket InstallationExtended Bracket InstallationSpecification Electrical SpecificationFCC Rules
Do not install the device in a place subject to direct sun light, humidity, dust or soot.Do not place a magnet near the product. Do not place the device next to heating equipments.When cleaning, do not splash water on the device; wipe it clean with smooth cloth or towel. Safety Precautions-3-The list above is to keep user’s safety and prevent any loss. Please read safety precautions carefully before use.Be careful not to let liquid like water, drinks or chemicals leak inside the device.Clean the device often to remove dust on it.It may cause a damage or a failure to the product.It may cause a failure.
Do not drop the device.  Do not disassemble, repair or alter the device.Do not let children touch the devicewithout supervision. Do not use the device for any other purpose than specified.The warranty does not apply to any product damage cause by an arbitrary installation or repair.Safety Precautions-4-Do not damage the device. Contact your nearest dealer in case of a trouble or problem. The list above is to keep user’s safety and prevent any loss. Please read safety precautions carefully before use.
Product Description-7-
LED Status-8-
(unit : mm)Product Dimensions-9-< Extended bracket >< Front View > < Bracket >< Side View >
Pin Pin Name Description Color5SWIN 0 Switch Input 0 Purple6 SWIN 1 Switch Input 1 Brown7SW GND Switch GND Gray8WGD D0 Wiegand Data 0 Green9WGD D1 Wiegand Data 1 whiteCables and Connectors-10-10 WGD GND Wiegand GND Black11 485 TRX+ 485 TRX+ Blue(white string)12 485 TRX- 485 TRX- Yellow(black string)13 485 GND 485 GND White(black string)14 PWR IN Power IN Red15 PWR GND Power GND Black (white string)
Power ConnectionPin Pin Name Color14 PWR IN Red15 PWR GND Black (white string)-11-12V ±10%, at least 500mA.Comply with standard IEC/EN 60950-1.When sharing the power with other devices, use a power supply with a higher current ratings.Recommended Power Supply:
Pin Pin Name Color11 485 TRX+ Blue (white string)12 485 TRX- Yellow (black string)13 485 GND White (black string)RS485 Connection for Host Communication-12-
Pin Pin Name Color11 485 TRX+ Blue (white string)12 485 TRX- Yellow (black string)13 485 GND White (black string)RS485 Connection for Secure I/O-13-Max Number of Devices:Maximum eight(8) devices (including master) within an RS485 loop.
Pin Pin Name Color5SWIN 0 Purple6 SWIN 1 Brown7SW GND GrayDigital Input Connection (Alarm, Emergency S/W)-14-
Pin Pin Name Color5SWIN 0 Purple6 SWIN 1 Brown7SW GND GrayDigital Input Connection (RTE, Door sensor)-15-
Pin Pin Name Color8WGD D0 Green9WGD D1 White10 WGD GND BlackWiegand InputWiegand Input/Output-16-Pin Pin Name Color8WGD D0 Green9WGD D1 White10 WGD GND BlackWiegand Output
Wall-mount Bracket InstallationFix the wall mount bracket on a wall using the wall mounting screws Hook Xpass Slim on the wall mount bracket-17-Fix Xpass Slim and wall mounting bracket using the mounting screw
Assemble the extended bracket using the provided screwsExtended Bracket InstallationMount the extended bracket to the desired location using the wall mounting screws-18-Hook Xpass Slim on the extended bracketFix Xpass Slim and the extended bracket using the mounting screw
CPU  32 bit Micro-processorMemory 1MB FLASH + 16MB SDRAM RF Card 13.56 MHz ISO14443A/B, ISO15693, Mifare/DesFire(CSN), Inside(CSN), Felica(IDM)User Capacity 40,000 userLog Capacity 50,000 logInterfaces RS485, WiegandIn or OutIP Rate IP65 classSound  Multi-tone BuzzerSpecification-19-LED Multi-color LED RTC  Lithium-ion Rechargeable BatteriesI/OTamper x 1Switch Input x 2 Wiegandx 1Power 12VDCOperating Temperature -20 ~ 50°C Size 80 x 120 x 11.4mm (W x H x D ) Certificates CE, FCC, KCC, RoHS, IP65Improper replacement of the battery may result in an explosion. Please use the specified battery according to proper instructions.Caution for RTC Battery
Electrical SpecificationMin. Typ. Max. NotesPowerVoltage (V) 10.8 12 13.2 Use regulated DC power adaptor onlyCurrent (mA) - 500Switch InputVIH (V) - TBD -VIL (V) - TBDPull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistorsTTL/Wiegand OutputVOH (V)-5--20-VOH (V)-5-VOL (V) - 0.8 -Pull-up resistance (Ω) - 10k - The outputs ports are open drain type, pulled up with 10k resistors internallyRelaySwitching capacity (A) - - 10.3 30V DC125V ACSwitching power (resistive) - - 30W37.5VA DCACSwitching voltage (V) - - 110125 DCAC
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential CautionWarningInformation to UserFCC Rules-21-to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can  radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures:1. Reorient / Relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.4. Consult the dealer or an experienced radio/TV technician for help