Suprema BLROC BioLite Net User Manual

Suprema Inc. BioLite Net

User manual

2                                        This manual is provided for information purpose only. All information included herein is subject to change without notice. Suprema is not responsible for any changes, direct or indirect, arising from or related to us of this manual.   ⓒ  Copyright 2008 Supremainc. All rights reserved.
 3 Contents Contents ..................................................................................................................... 3 Safety Instructions .................................................................................................... 5 1. Before Use ............................................................................................................. 6 1.1 Components ..................................................................................................................... 6 1.2 Body.................................................................................................................................. 7 1.3 Methods for fingerprint input ............................................................................................. 8 1.4 System setup procedure ................................................................................................. 10 1.4.1 Registering the initial administrator .......................................................................... 11 1.4.2 Network configuration............................................................................................... 12 1.4.3 Stand-alone configuration ........................................................................................ 15 1.4.4 Configuring Secure I/O ............................................................................................. 17 1.4.5 Configuring environment settings ............................................................................. 18 1.5 Authorization methods .................................................................................................... 19 1.5.1 Finger Only ............................................................................................................... 19 1.5.2 Finger or PIN ............................................................................................................ 20 1.5.3 Finger and PIN ......................................................................................................... 23 1.5.4 PIN Only ................................................................................................................... 24 1.5.5 Card Only ................................................................................................................. 25 2. User Management................................................................................................ 26 2.1 Enrolling a user ............................................................................................................... 26 2.2 Editing a user data .......................................................................................................... 28 2.3 Deleting a user data ........................................................................................................ 31 3. Configuration for Screen and Sound ................................................................. 32 3.1 Date, Time ...................................................................................................................... 32 3.2 Backlight ......................................................................................................................... 33 3.3 Sound ............................................................................................................................. 34 4. Device Configuration .......................................................................................... 35 4.1 Authorization ................................................................................................................... 35 4.2 In/Out .............................................................................................................................. 40 4.3 System ............................................................................................................................ 47 5. Attendance Management .................................................................................... 51 5.1 Operating environment ................................................................................................... 51 5.2 Setup for attendance management ................................................................................ 52 5.3 Operation modes ............................................................................................................ 53 5.3.1 Key Input .................................................................................................................. 53 5.3.2 Manual ...................................................................................................................... 53 5.3.2 Auto .......................................................................................................................... 54 5.3.3 Fixed ......................................................................................................................... 55 6. FAQ ....................................................................................................................... 56 6.1 Error messages .............................................................................................................. 56 6.2 Troubleshooting .............................................................................................................. 57 6.3 Usage summary.............................................................................................................. 58 6.4 System Installation .......................................................................................................... 59
 4 6.4.1 Cable specifications ................................................................................................. 59 6.4.2 Installing the bracket ................................................................................................ 60 6.4.3 Connecting Power & RS-485 ................................................................................... 61 6.4.4 Connecting the switch .............................................................................................. 61 6.4.5 Connecting the relay ................................................................................................ 62 6.4.6 Connecting Network ................................................................................................ 63 6.4.7 Connecting Wiegand ............................................................................................... 63 6.4.8 Electrical specifications ............................................................................................ 64 6.5 Specifications ................................................................................................................. 65 6.6 FCC Notice ..................................................................................................................... 67
 5 Safety Instructions   Installation             In Use                     Do not arbitrarily install or repair the product.  The warranty does not apply to any product damage  caused by an  arbitrary  installation or  repair. Use the power adapter provided or one for 12V 0.5A or above. Endure that password does not exposed to unauthorized individuals. Frequent change of password is recommended. Any illegal access to your product may happen. Be cautioned for the fingerprint contact area not to be contaminated or damaged by dirty hands or foreign materials. It may affect fingerprint  recognition performance  or cause a failure.  Do not forcibly press the buttons of the product and avoid any contact with sharp object to the device.  It may cause  a failure. Do not clean the device with any form of liquid. Use soft and dry cloth only.  When sharing the power with other devices such as electric  door lock, check the power capacity considering power  requirements for each device. If appropriate power is not used,  it may not operate normally.
 6 1. Before Use 1.1 Components                                   Main Body Wall mounting bracket Extended bracket (Option) Fixing Screws (2 EA) Knife Blocks(2 EA) Star-shape wrench (For fixing bracket) Adapter (Option) Shrinkable Tubes Ethernet Connector The components shown above may differ depending on the installation environment.
 7 1.2 Body                 No.  Name  Description 1  LCD Display The operation status is displayed. 2  Key Pad 0–9 Buttons: Used to enter the ID and password. < > Arrow Buttons: Used to move the selected item.  Button: Used to select the desired function.  Button: Used to enter or exit the menu.  Button: Used to exit from the menu or cancel the desired action. 3  LED Lamp The operation status is displayed with an alert sound. – Green (Sound: beep beep beep beep!): Authorization success – Red (Sound: beep beep beep!) : Authorization failure – Pink (Sound: beep!) : Processing – Blue and Yellow blink in turn at an interval of 2 seconds (No sound): No IP address is given because DHCP is set in TCP/IP Setup – Blue and Sky Blue blink in turn at an interval of 2 seconds (No sound): Normal operation – Red and Pink blink in turn at an interval of 2 seconds (No sound): Device locked or no administrator – Blue and Red blink in turn at an interval of 2 seconds (No sound): The time is reset due to battery discharge. – At first use, Red blinks at an interval of 2 seconds (No sound): Initialization error, Consult with the manufacturer. – In normal use, Red blinks at an interval of 2 seconds (No sound): On the watch. – Yellow blinks shortly (No sound): Entry standby or in communication for getting an IP when DHCP is set in TCP/IP Setup 4  Fingerprint Touch Area Used to input a fingerprint for authentication. LCD DisplayLED LampFingerprint Touch AreaKey Pad
 8 1.3  Methods for fingerprint input BioLite Net can easily recognize fingerprints even though the angle and location of the pattern change. However, it is recommended to properly input fingerprints for more precise recognition.  Selecting a finger on fingerprint enrollment              How to proerply place a fingerprint           Place your finger firmly on the sensor area.  Adjust the finger so that its middle position can be located in the center of the sensor. When the finger is vertically placed or its angle goes astray, the recognition may be a failure. Up to two fingerprints can be enrolled for each user in preparation of any abnormal situation like having a wounded finger or carrying an object with a hand.  In the case of a low recognition, the user can register  the same fingerprint twice to increase the recognition  rate.  It is recommended to use the index or middle finger. In case of other fingers, the recognition rate  decreases because it tends to be more difficult to  place the finger in the center of the sensor area. Place the first Finger When enrolling your fingerprint, the first finger input window prompts. Then register the desired finger on the terminal as shown in the figure below. When the re-entry window appears with a “tick” sound, re-enter the previously enrolled finger. The fingerprint input is made twice. (Gently push your finger on the sensor to have a full fingerprint.)
 9    In case fingerprint is not recognized normally                 Cautions while registering your fingerprint                  BioLite Net is designed to normally operate regardless of weather change or the angle and location of the fingerprint to place. However, the recognition rate may vary depending on the external environment or fingerprint condition.  In abnormal cases, follow the directions below: 1. Retry after drying the wetness of your finger. 2. When your finger is too dry, retry after blowing on your fingertip. 3. When you have a cut on your registered finger, register another fingerprint. The initial fingerprint registration is important. Because the recognition process compares the scanned fingerprint with the registered one, an abnormally registered fingerprint can cause a failure.  To increase the recognition rate, follow the directions below: 1. Put the center of your fingerprint on the middle of the sensor. 2. If you have a cut in your finger or your fingerprint is not clear enough, retry with another finger. 3. When fingerprint recognition is in progress, do not move your fingerprint .
 10 1.4 System setup procedure                                      Install the system according to the environment - Grasp the locations for installation site, door open switch,   dead bolt, and such. - Install the system (see 6.4).Step 1 Register users - Use the system after user registration (see 2.1).Step 6 Register an initial administrator - Register the initial administrator for setting devices (See 1.4.1). Step 2 Configure the environment - Configure various environments (see 1.4.5). Step 5 Test for system operation - Check the door lock/unlock status and switch operation. - Deliver the setting items to the customer. Step 4 - Network configuration (see 1.4.2) - Stand alone configuration (see 1.4.3.) or Secure I/O configuration (see 1.4.4) Step 3  Configure the system
 11 1.4.1  Registering the initial administrator There is no administrator set for the product in the initial status. So register an administrator for configuring the environments for relay, door open switch, door open detection sensor, and such.  1. When the product is connected, a window appears as shown in the right figure. Enter an ID and press OK.   2. When the authorization mode window appears, use   /   buttons to move to PIN Only, and press OK.    3. When the password entry window appears, enter the desired password and press OK.    4. When the password re-entry window appears, enter the previously input password again and press OK.    5. The completion message window appears.           Operation Mode PIN Only Enroll Enter PIN **** Enroll Confirm PIN ****Enroll Completed  This procedure is necessary to temporarily configure the installation-related settings. Modify the administrator information after the installation is complete. Enter ID 1Enroll Admin
 12 1.4.2 Network configuration The network configuration is required to connect the dedicated PC software or other devices via network. Configure the settings according to the communication environment in your place.  [In case of configuring the network via Ethernet] 1. Connect the terminal to the computer that has the dedicated PC software according to the network environment after seeing “6.4.6 Connecting network.”  2. Configure the settings for TCP/IP port and server according to the installation environment.                        Use   /   buttons to set whether or not to use DHCP and press OK.   Server IP 192.168.1.30 TCP/IP Server Port 1480 TCP/IP Subnet Mask 255.255.255.0 TCP/IP Server Use TCP/IP Port 1471 TCP/IP Item TCP/IP In/Out Device  In/OutDHCP Not Use TCP/IP IP Address 192.168.1.35 TCP/IP Gateway 192.168.1.10 TCP/IP ※ The following example explains how to directly connect the server PC without using DHCP. Use   /  buttons to select the Device icon and press OK. Use   /  buttons to select the In/Out icon  and press OK. Use   /  buttons to select the TCP/IP and press OK. Enter the IP address   and press OK.Enter Port and   press OK. Enter Server Port and press OK. Enter the Gateway using numeric and arrow buttons and press OK. Enter Server IP address using numeric and arrow button and press OK. Enter IP address using numeric and arrow button and press OK. Use   /  buttons to select the Use and press OK. Cont.
 13               ※IP Address/Gateway/Subnet Mask Setup: If DHCP is used, the values for  IP address, gateway, and subnet mask are automatically assigned. Otherwise, set DHCP  to Not Use and enter the corresponding values.  (When the right arrow is pressed, “.” is entered while the left arrow deletes characters  one by one.) ※Server: To directly connect the server of the dedicated PC software that enables  monitoring and setting the terminal, use Server for its setup and enter the values for  IP address and port number. (Refer to the dedicated PC software manual.) ※TCP/IP Port, Server Port: Should be the same values defined in the dedicated  PC software. It is recommended to set the TCP/IP port to “1471” and Server to “1480.” (When the port number is modified as you want, TCP/IP communication may not be active.)     The completion message window appears.  Use   /  buttons to  set whether or not to support 100Base-T and press OK.  Completed  100Base-T support Not support TCP/IP When you exit from the menu before completing the TCP/IP setting, the data is not stored so please finish the remaining steps until the setting completion message appears.
 14  [In case of configuring the network via RS-485] 1. Connect the terminal to the computer that has the dedicated PC software or to another device according to the network environment after seeing “6.4.3 Connecting Power & RS-485.”  2. Configure the settings for RS-485 according to the installation environment.                          Device  In/OutItem Serial Conn. In/Out The completion message window appears. Completed Use /  buttons to◀▶  select 115200 for PC connection speed and press OK. Use  /  buttons to◀▶  select Not Use for termination and press OK. Baudrate 115200 Serial Conn. Type PC Conn. Serial Conn. Termination Not Use Serial Conn. Use   /  buttons to select the Device icon and press OK. Use   /  buttons to select the PC Conn. and press OK. Use   /  buttons to select the In/Out icon and press OK. Use   /  buttons to select the Serial Conn. and press OK.
 15 1.4.3 Stand-alone configuration This configuration is required to use the device for stand alone purpose, which device which requires no communication with PC or other devices.    1. As shown in the figure, connect BioLite Net to respective switches.             2. Configure the internal relay settings as shown below. (It is explained based on the figure above.)                    For actual wring method,  see “6.4 System Installation.”.  Follow the instructions below only when the dedicated PC software is not used. When using the software, refer to the software manual. Use   /  buttons to select Internal and press OK. Use   /  buttons to select Input 0 and press OK. Use   /  buttons to select N.O and press OK. *N.O/N.C Relay Internal Door Exit ButtonInput 0 Internal TypeN.O Exit Button Use   /  buttons to select the In/Out icon and press OK. Press MENU -> Enter ID   -> Enter the password -> Use   /  buttons to select the Device icon and press OK. Use   /  buttons to select Door and press OK. Device In/Out ItemDoor In/Out Cont.
 16                            ※ Opening Mode - Temporary Open: When the door is open, it is automatically closed after a specific time. - Toggle: The door is open after the first authorization success and it remains unlocked  until the second authorization success.          Enter the time and press OK. *The time is set for automatically closing the door after the specified time. Use   /  buttons to select Not Use for Held Open Alarm and press OK. *Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/SIO Relay1 Door Sensor Input 1 Internal Held Open Alarm Not Use Door Use   /  buttons to select N.O and press OK. *N.O/N.C Use   /  buttons to select Input 1 and press OK. *Not Use/Input0/Input1 Use   /  buttons to select Temporary Open for opening mode and press OK. * Temporary Open/ Toggle Opening Mode Temporary Open DoorTypeN.O Door Sensor Open Time 3 Door Use   /  buttons to select Not Use for Forced Open Alarm and press OK. *Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1 The completion message window appears. Forced Open Alarm Not Use Door  Complete  When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message “Complete” appears.
 17 Cont. 1.4.4 Configuring Secure I/O This connects BioLite Net to Secure I/O.  1. Connect wires between BioLite Net, Secure I/O, and respective switches as shown below.               2. Configure the relay settings as shown below. (Based on the figure above)                    For actual wiring, see “6.4 System Installation.” Follow the instructions below only when the dedicated PC software is not used. When using the software, refer to the software manual. Use   /  buttons to select SIO Relay 0 and press OK. Use   /  buttons to select SIO Relay 0 and press OK. (*Not Use/ SIO Input 0/ SIO Input 1) Relay SIO Relay 0 Door Exit ButtonSIO Input 0 SIO Relay 0Use   /  buttons to select N.O and press OK.TypeN.O Exit Button Device In/Out Use   /  buttons to select the In/Out icon and press OK. Press Menu -> Enter ID -> Enter password ->Use /  buttons to select the Device icon and press OK. ItemDoor In/Out Use   /  buttons to select Door and press OK.
 18                         ※Opening Mode -Temporary Open: When the door is open, it is automatically closed after a specific time. -Toggle: The door is opened after the first authorization success and it remains unlocked until the second authorization success.       1.4.5 Configuring environment settings  Settings for date and time: Set the values as “3.1 Date, Time.”  Fingerprint authorization related settings: Set the values after reading the case of fingerprint selection in “4.1 Authorization.”  Operation mode setting: Finish the setting after seeing the operation mode selection case in “4.1 Authorization.” ※Sync. Button (In case of using Secure I/O) Sync. button should be pressed when Relay setting is completed. Enter the time and press OK. *The time is set for automatically closing the door after the specified time. Use   /  buttons to select Not Use for Held Open Alarm and press OK. *Not Use/Sound/Backlight/ Sound & Light/SIO Relay0/ SIO Relay1 Door Sensor SIO Input 1 SIO Relay 0 Held Open Alarm Not Use DoorUse   /  buttons to select N.O and press OK. Use   /  buttons to select SIO Input 1 and press OK. *Not Use/ SIO Input0/ SIO Input1 Opening Mode Temporary Open Door Use   /  buttons to select Temporary Open for opening mode and press OK. * Temporary Open/Toggle TypeN.O Door SensorOpen Time(sec) 3 Door Use   /  buttons to select Not Use for Forced Open Alarm and press OK. *Not Use/Sound/Backlight/ Sound & Light/SIO Relay0/ SIO Relay1 The completion message window appears. Forced Open Alarm Not Use Door  Complete  When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message “Complete” appears.
 19 1.5 Authorization methods For changing the terminal authorization method, see the operation mode selection case in “4.1 Authorization.” To separately set the authorization method for each user, see “2.2 Editing a user data.”    1.5.1 Finger Only When the user authorization method is set to “Finger Only,” you can open the door by using the three different methods:  1. Fingerprint recognition 2. Fingerprint recognition after entering ID 3. Fingerprint recognition after identifying user card   Fingerprint recognition          Fingerprint recognition after entering ID              Input the fingerprint of the user. The door is open with the authentication success message. Access Granted ID : 2BioLite Net 10:33:02 BioLite Net 10:33:02 Enter ID2Input the fingerprint   of the user. The door is open with the authentication success message. Access Granted ID : 2 Enter the ID of the user and press OK.
 20  Fingerprint recognition after identifying user card                 1.5.2  Finger or PIN When the user authorization method is set to “Finger or PIN,” you can open the door by using the five different methods:  1. Fingerprint recognition 2. Fingerprint recognition after entering ID 3. Password entry after entering ID 4. Fingerprint recognition after identifying the user card 5. PIN entry after identifying the user card  Fingerprint recognition        Input the fingerprint of the user. The door is open with the authentication success message. Access Granted ID : 2BioLite Net 10:33:02 BioLite Net 10:33:02 Input the fingerprint of the user. The door is open with the authentication success message. Access Granted ID : 2 Place the user card on the SUPREMA logo area.
 21  Fingerprint recognition after entering ID             PIN entry after entering ID             Fingerprint recognition after identifying user card             Enter Finger or PIN****BioLite Net 10:33:02 Enter ID2Input the fingerprint of the user. The door is open with the authentication success message. Access Granted ID : 2 BioLite Net 10:33:02 Enter ID2The door is open with the authentication success message. Access Granted ID : 2 BioLite Net 10:33:02 Input the fingerprint of the user. The door is open with the authentication success message. Access Granted ID : 2 Place the user card on the SUPREMA logo area. Enter the password of the user and press OK. Enter the ID of the user and press OK. Enter the ID of the user and press OK.
 22  PIN entry after identifying the user card                           BioLite Net 10:33:02 The door is open with the authentication success message.  Access Granted ID : 2 Place   the user card on the SUPREMA logo area. Enter Finger or PIN ****Enter the password of the user and press OK.
 23 1.5.3  Finger and PIN When the user authorization method is set to “Finger and PIN,” you can open the door by using the three different methods:  1. PIN entry after identifying fingerprint 2. PIN entry after entering ID and fingerprint 3. PIN entry after entering user card and fingerprint   PIN entry after identifying fingerprint                PIN entry after entering ID and fingerprint              The door is open with the authentication success message. Access Granted ID : 2 Enter PIN****BioLite Net 10:33:02 Input the fingerprint of the user. BioLite Net 10:33:02 Enter ID2The door is open with the authentication success message. Access GrantedID : 2Enter PIN **** Input the fingerprint of the user. Enter the password of the user and press OK. Enter the password of the user and press OK. Enter the ID of the user and press OK.
 24  PIN entry after entering user card and fingerprint                1.5.4 PIN Only When the user authorization method is set to “PIN Only,” you can open the door by using the two different methods:  1. PIN entry after entering ID 2. PIN entry after identifying user card   PIN entry after entering ID              BioLite Net 10:33:02 The door is open with the authentication success message.Access GrantedID : 2Place the user card on the SUPREMA logo area. Enter PIN **** Access Granted ID : 2 Input the fingerprint of the user. The door is open with the authentication success message.Enter the password of the user and press OK. Enter the password of the user and press OK. Enter the ID of the user and press OK. Enter Finger or PIN ****BioLite Net 10:33:02 Enter ID2
 25   PIN entry after identifying user card                 1.5.5 Card Only When the user authorization method is set to “Card Only,” you can open the door by following the instructions below:                  Place the user card on the SUPREMA logo area. BioLite Net 10:33:02 Access Granted ID : 2 Place the user card on the SUPREMA logo area. Enter Finger or PIN****BioLite Net 10:33:02 For “Card Only,” register the card user on the dedicated PC software first. The door is open with the authentication success message.The door is open with the authentication success message. Enter the password of the user and press OK. Access Granted ID : 2
 26 2. User Management The user management and other environment settings can be updated after authorizing the registered administrator (see “1.4.1 “Registering the initial administrator”).    2.1 Enrolling a user You can enroll a new user as shown below:    1. Use   /   buttons to select the User ( ) icon and press OK.    2. Use   /   buttons to select Enroll ( ) icon and press OK.    3. The ID that can be used appears. Use it or enter another ID and press OK. (1–8 digit number)      4. Use   /   buttons to select Level and press OK. (Level: General /Administrator) ※The user enrollment and environment configuration are enabled only in Administrator level.    User Enroll Enter ID 3 Enroll Level General Enroll ID is used to edit or delete the user data so please keep it carefully.
 27  5. Enter the finger or PIN depending on the operation mode. (Password: 4–8 digit number, Fingerprint: 1st finger or 1st + 2nd fingers)      Finger Only/Finger or PIN/Finger and PIN         ※In order to skip the second fingerprint enrollment after enrolling the first  fingerprint, press ESC. ※The user can enroll one or two fingerprints for passing the door.    PIN Only/ Finger and PIN       ※For password, it is recommended to enter 4 to 8 digit number not to be easily exposed.    6. When the user enrollment is successfully done, the completion message window appears. ※User can be enrolled up to maximum 5000.   Completed Enter the required information after selecting Device > Authorization > Operation Mode > Auth Mode. Place the firstfinger again Place the first finger Place the second finger(Skip=ESC)Place the first finger on the sensor. Place the same finger on the sensor again. Place the second finger in the same manner. Confirm PIN*****EnrollEnter PIN ***** Enroll
 28 2.2  Editing a user data You can modify the data of the previously enrolled user.   1. Use   /   buttons to select the User ( ) icon and press OK.    2. Use   /   buttons to select the Edit ( ) icon and press OK.    3. Enter the ID or fingerprint of the desired user and press OK.    4. Use   /   buttons to select the desired item and press OK. ※ select any of Level/Operation Mode/Security Level/Finger/PIN/Access Group(1~4)    Changing the user level         ※The settings for user, screen/sound, device, and such can be configured   only by the administrator level.   User Edit Enter ID/Finger 4Edit Item Level Edit Use   /  buttons to select Level and press OK. Use   /  buttons to select General or Administrator. Press OK. LevelGeneral Edit
 29  Changing the authorization method                Autho※rization methods: *Finger Only/PIN Only/Finger or PIN / Finger and PIN/Card Only/Per Device - Finger Only: Only fingerprint is used. - PIN Only: Only PIN is used. - Finger or PIN: Fingerprint or PIN is used. - Finger and PIN: Both fingerprint and PIN are used. - Card Only: Only user card is used. - Per Device: The mode set in “Device > Authorization > Operation Mode >  Auth Mode” is used.   Changing the security level of the user         ※Security Level: *Per Device/Lower/Low/Normal/High/Higher - Per Device: The security level in “Device>Authorization>Fingerprint>”  on page 37 is applied. - The higher the security level, the more sensitive the fingerprint recognition. But the authorization failure rate can increase.  This authorization method setting for each user has higher priority than the terminal setting that has been defined in Device > Authorization > Operation Mode > Auth Mode. Note that this function is applied to the case when the user enters ID or card and when Use is set in Device > Authorization > Operation Mode  > Private Auth Item Operation Mode Edit Use   /  buttons to select Operation Mode and press OK. Use   /  buttons to select an desired operation mode and press OK. Press OK.Operation Mode Finger Only Edit Use   /  buttons to select Security Level and press OK. Use   /  buttons to select a security level. Item Security Level Edit Security Level Normal Edit Press OK.
 30  Changing the fingerprint of the user              Changing the PIN of the user          Changing the access group               Item Access Group1 Edit Select Full Access Access Group1Setting the access groups other than Full Access or No Access is  enabled through the dedicated PC software only. Using the terminal,  you cannot add or edit them but only selecting them is enabled  for each user. Place the first finger again Item Fingerprint Edit Place the second finger (Skip=ESC) Place the first fingerUse   /  buttons to select Fingerprint and press OK. Place the first finger on the sensor. Place the same finger on the sensor again. Enroll the second fingerprint in the same manner. Item PIN Edit Use   /  buttons to select PIN and press OK. Enter the desired password and press OK. After re-entering the password of the user, press OK. Enter PIN**** Edit Confirm PIN **** Edit Press OK. Use   /  buttons to  select any of Access   Group and press OK. Use   /   buttons to select access privilege for selected Access Group *Full Access/No Access/Not Use/Or user designated Access Group
 31 2.3  Deleting a user data You can delete unnecessary user data.  1. Use   /   buttons to select the User ( ) icon and press OK.    2. Use   /   buttons to select the Delete ( ) icon and press OK.    3. After entering the ID or finger to delete and press OK.    4. When the action is successfully made, the message Deletion appears.  ※The deleted user cannot be recovered. If necessary, enroll it again.           - If all the users including the administrator are deleted, you must register the initial administrator again (see 1.4.1). - When an administrator is deleted by mistake except normal users, the initial administrator registration step does not require registering normal users. User Delete Enter ID/Finger 4Delete Deletion
 32 3. Configuration for Screen and Sound 3.1 Date, Time You need to set the current system date and time. After setting the date and time, the log data can store correct information.  1. Use   /   buttons to select the Screen, Sound () icon and press OK.    2. Use   /   buttons to select the Date, Time ( ) icon and press OK.    3. Enter the current date by following the suggested format and press OK. For example, in case of November 15 in 2008, enter “20081115” and press OK.   4. Enter the current time by following the suggested format and press OK. For example, in case of 10:20 55 AM, enter “102055” and press OK.   Screen, Sound Date, Time Date(YYYYMM00) 20081115 Date, Time Time(hhmmss) 102055 Date, Time
 33  3.2 Backlight 1. Use   /   buttons to select the Screen, Sound () icon and press OK.    2. Use   /   buttons to select Backlight ( ) icon and press OK.    3. Use   /   buttons to select a backlight operation status and press OK.     Always On          On at Use         When no operation is made, it sets the time (second) to switch the screen. Enter the backlight-on time (second) on the menu window. Mode Always On Backlight Timeout(sec) 20 Menu Duration Mode On at Use Backlight Timeout(sec) 20 Backlight ※When no input is made, it sets the time to exit from the menu. ※When no input is made on the menu window, it sets the time to automatically turn off the backlight. Screen, Sound Backlight ModeAlways On Backlight Use   /  buttons to select the Always On and press OK. Use   /  buttons to select the On at Use and press OK.
 34 3.3 Sound  1. Use   /   buttons to select the Screen, Sound () icon and press OK.   2. Use   /   buttons to select Sound ( ) icon and press OK.    3. Use   /   buttons to select the sound operation status and press OK.        Or Screen, Sound Sound Mode On Sound ModeOff Sound
 35 4. Device Configuration 4.1 Authorization 1. Use   /   buttons to select the Device ( ) icon and press OK.    2. Use   /   buttons to select the Authorization () icon and press OK.    3. Use   /   buttons to select any of Fingerprint, and Operation Mode and press OK.     In case of Fingerprint                    Authorization Device Item Fingerprint Authorization Use   /  buttons to select Fingerprint and press OK. Use   /  buttons to select Security Level and press OK. Use   /   buttons to select Security Level and press OK. * Normal /Secure/More Secure Use   /  buttons to select Image Quality and press OK. Use   /  buttons to select Image Quality and press OK. *Normal/High/Low ItemSecurity Level Fingerprint Security Level Normal Fingerprint ItemImage Quality FingerprintImage Quality Normal FingerprintItemFingerprint Authorization Cont.
 36 Cont.                                          Item Fast Mode Fingerprint Fast Mode Auto Fingerprint Item Scan Timeout Fingerprint Scan Timeout(sec) 10 Fingerprint Item Matching Timeout Fingerprint Matching Timeout(sec) 3 Fingerprint Use   /  buttons to select Sensitivity and press OK. Use   /  buttons to select Sensitivity level and press OK.  Use   /  buttons to select Check Duplicate and press OK. ItemSensitivity Fingerprint Sensitivity 7 Fingerprint ItemCheck Duplicate FingerprintCheck Duplicate Not Use Fingerprint Use   /  buttons Check Duplicate and press OK. * Not Use /Use Use   /  buttons to select Fast Mode and press OK. Use   /  buttons to select Scan Timeout and press OK. Use   /  buttons to select Matching Timeout and press OK. Enter Scan Timeout (second) and  press OK. Enter Matching Timeout (second)and press OK. Use   /  buttons to select desired Fast Mode and press OK. *Auto/Normal/Fast /Faster
 37         ※ Security Level: The higher the security level, the more sensitive the fingerprint  recognition. But the authorization failure rate can increase. ※ Image Quality: It is the image quality level used when entering the fingerprint data. In case of Low, the fingerprint can be easily input but the correct  authorization is not guaranteed. ※ Sensitivity: The higher the value, the more sensitive the sensor. ※ Check Duplicate: When enrolling a user, it determines whether or not to check the  fingerprint data is already enrolled. ※ Fast Mode: You can set the fingerprint recognition speed. If it is set to Fast,  the recognition accuracy may decrease. ※ Scan Timeout: You can set the terminal standby time for entering fingerprint.  If entry is not made within the specified time, the message,  ‘Entry time is over” appears. ※ Matching Timeout: You can set the maximum authorization time after entering fingerprint.  If this time limit expires, matching stops and the authorization fails. ※ Template Type: Format used in the terminal when identifying fingerprints (SUPREMA/SIF) - SUPREMA: SUPREMA’s own template format, SIF: ISO/IEC compatible template format (To change the template format, there must be no fingerprint data stored on the terminal.) Item Template TypeFingerprint Template Type SUPREMA Fingerprint Use   /  buttons to select Template Type and press OK. Use   /  buttons to select template format and press OK. *SUPREMA/SIF
 38 Cont.  In case of Operation Mode               ※ Sensor Mode:  *Always On/ID Entered/OK Pressed - Always On: The sensor always waits for a fingerprint input. - ID Entered/OK Pressed: If you enter ID or press OK, you can enter the time zone  for using the sensor. ※ Applied time: Use the dedicated PC software for setting the time zone except  All Time and Not Use. With the terminal, you cannot add and edit it but only selection  is not possible.           ※Auth Mode: *Finger Only/PIN Only/Finger or PIN / Finger and PIN /Card Only If no authorization setting exists for each user,  the user authorization method that has been set  on the terminal is applied.  ※Double Mode: When consequent two users are  authorized successfully, entrance  and exit are allowed.  Use /  buttons to ◀▶select the applicable time zone and press OK. Schedule All Time Always On Item Operation Mode Authorization Use   /  buttons to select Sensor Mode an press OK. Use   /  buttons to select a sensor mode. *Always On/ID Entered/OK Pressed Item Sensor Mode Operation Mode Sensor Mode Always On Operation Mode Use   /  buttons to select Operation Mode an press OK.Use /  buttons to◀▶  select the authorization method press OK. Use /  buttons to ◀▶select the applicable time zone and press OK. Use   /  buttons to set whether or not to use the double mode and press OK. Item Auth Mode Operation Mode Auth Mode Finger Only Operation ModeSchedule All Time Finger Only Double Mode Not Use Finger Only Use   /  buttons to select Auth Mode and press OK.
 39                    ※Card entry methods: - Use Template: After placing the user card, enter your fingerprint and PIN. Then the  terminal matches the enrolled fingerprint template with the template  in the card for identification. - Use CSN: Identifies only the serial number of the card. Use /  buttons to◀▶  set whether or not to use the mode and press OK. Use /  buttons to◀▶  set whether or not to use cards and press OK. Use /  buttons to◀▶  select the card entry method and press OK. * Use Template/Use CSN Item Private Auth Mode Operation Mode Private Auth Mode Use Operation Mode Item Card Operation Card Use Operation Mode Type Use Template Card Use   /  buttons to select Private Auth Mode an press OK. Use   /  buttons to select Card an press OK.
 40 4.2 In/Out 1. Use   /   buttons to select the Device ( ) icon and press OK.   2. Use   /   buttons to select In/Out () icon and press OK.   3. Use   /   buttons to select any of Serial Conn., Tamper On, Door Wiegand, and TCP/IP and press OK.     In case of Serial Conn. (selection of connection method)                          Use /  buttons to◀▶  set whether or not to use the termination and press OK. The completion message window appears. Type Host Serial Conn. Termination Not Use Serial Conn.  Completed  Use /  buttons to◀▶  set whether or not to use the termination and press OK. The completion message window appears. Type Slave Serial Conn. Termination Not Use Serial Conn.  Completed  Use /  buttons to ◀▶ set whether or not to use the termination and press OK. The completion message window appears. Type Ext. Host Serial Conn. Termination Not Use Serial Conn.  Completed  ※Serial Conn.: It is used  for RS485 communication  or direct PC connection. Device In/Out Item Serial Conn. In/Out Item Serial Conn. In/Out Use   /  buttons to select Serial Conn. and press OK. Cont. Use   /  buttons to select Host and press OK.Use   /  buttons to select Slave and press OK.Use   /  buttons to select Ext. Host and press OK.
 41                               ※ Methods - PC  Conn.: Directly connects to PC through RS485 - Host/Slave: Connects between terminals through RS485. Used when the terminal  interoperates with the BioAdmin software.  (Refer to the BioAdmin manual.) - Ext. Host/Ext. Slave: Connects between terminals through RS485. Used when  the terminal interoperates with the BioStar software.  (Refer to the BioStar manual.) - Termination: Used when the communication line is too long or the signal strength  changes drastically (It enforces the signal strength). - Host/Slave, Ext. Host/Ext. Slave: Connects between terminals through RS485. The communication speed is fixed to  115200 baudrate. The completion message window appears. Completed Use /  buttons to ◀▶ set whether or not to use the termination and press OK. The completion message window appears. Type Ext. Slave Serial Conn. Termination Not Use Serial Conn.  Completed  Use /  buttons to◀▶  set whether or not to use the termination and press The completion message window appears. Type Not Use Serial Conn. Termination Not Use Serial Conn  Completed  Use /  buttons to◀▶  set whether or not to use the termination and press OK.Baudrate 115200 Serial Conn. Type PC Conn. Serial Conn. Termination Not Use Serial Conn. Use   /  buttons to select Ext. Slave and press OK. Use   /  buttons to select Not Use and press OK. Use   /  buttons to select PC Conn. and press OK. Use   /  buttons to select Baudrate and press OK. *115200/57600/38400 /19200
 42  In case of Tamper On         ※ Tamper: *Ignore/Locked - Locked: When the device is forcibly removed, the Device is locked. (To release the lock, the administrator must perform authorization.)           Item Tamper On In/Out Press OK.Use   /  buttons to select Tamper On and press OK. Use   /  buttons to select a tamper method. Tamper OnIgnore In/Out
 43 In case of Door (When using the internal relay)                                      ※ Opening Mode - Temporary Open: When the door is open, it is automatically closed after a specific time. - Toggle: The door is opened after the first authorization success and it remains unlocked until the second authorization success. ※ It is used only when the stand-alone BioLite Net is installed without interoperating with the dedicated PC software. Item Door In/Out Use   /  buttons to select Door and press OK. Use   /  buttons to select Internal and press OK. Use   /   buttons to select Exit Button and press OK. * Not Use/ Input 0/ Input 1 RelayInternal Door Exit ButtonInput 0 Internal Use   /  buttons to select the type for Exit Button and press OK. *N.O/N.C Type N.O Exit Button Door Sensor Input 1 InternalUse   /  buttons to select a door sensor type and press OK. *N.O/N.C Use   /  buttons to select Door Sensor and press OK. *Not Use/InputOpening Mode Temporary Open Door Held Open Alarm Not Use Door Open Time(sec) 3 Door TypeN.O Door Sensor Use   /  buttons to select a opening mode and press OK. *Temporary Open/ Toggle Enter the time and   press OK. Use   /   buttons to select   the type for Held Open Alarm and press OK. * Not Use /Sound/Backlight/ Sound& Light/SIO Relay0/   SIO Relay1 Enter the held open time by using the Numeric buttons and press OK. *Held Open Time: Alarm ringing time when the open door is not closed. Forced Open Alarm Not Use Door Completed Use   /   buttons to select the type for Forced Open Alarm and press OK. *Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1 The completion message window appears. Held Open Time(sec) 30 Door When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message “Complete” appears.
 44  In case of Door (When using the SIO relay)                                     ※It is used only when the stand-alone BioLite Net is installed without interoperating with the dedicated PC software. Use   /  buttons to select the relay type and press OK. Use   /  buttons to select the exit button and press OK. * Not Use/SIO Input0/   SIO Input1 RelaySIO Relay0 DoorExit ButtonSIO Input0 SIO Relay0 Item Door In/Out Use   /  buttons to select Door and press OK. Use   /   buttons to select the type of the exit button and press OK. *N.O/N.C Type N.O Exit Button Door Sensor SIO Input1 SIO Relay0 Use   /  buttons to select the door sensor type and press OK. *N.O/N.C Use   /  buttons to select the door sensor and press OK. *Not Use/ SIO Input1 TypeN.O Door Sensor Enter the time and press OK and press OK.  Use   /  buttons to select the alarm type and press OK. *Not Use/Sound/Backlight/ Sound and Light/SIO Relay0/SIO Relay1 Held Open Alarm Sound Door Enter the time for Held Open Alarm by using the Numeric buttons and press OK. *Held Open Time: Alarm ringing time when the open door is not closed. Held Open Alarm(sec) 30 Door Opening Mode Temporary Open Door Use   /  buttons to select the type of the opening mode and press OK. *Temporary Open/ Toggle Open Time(sec) 3 Door Use   /   buttons to select the type for Forced Open Alarm and press OK. *Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1 The completion message window appears. Forced Open Alarm Not Use Door Complete
 45  In case of Wiegand            Wiegand ※types: *Card ID In/Card ID Out/User ID In/User ID Out - Card ID In: The card ID is entered. - Card ID Out: The card ID is output. - User ID In: The user ID is entered. - User ID Out: The user ID is output.                    Use /  buttons to◀▶  select Wiegand and press OK. *Card ID In/ Card ID Out/User ID In/ User ID Out/Not Use Item Wiegand In/Out Type Card ID In Wiegand When the user whose user ID is 2 registers the card ID (1234567), - Card ID In: When “1234567” is entered through the Wiegand port, the user is successfully authorized. - Card ID Out: When the user card is read through the terminal, the card ID “1234567” is output through the Wiegand port.  - User ID In: When “2” is entered through the Wiegand port, the user is successfully authorized. - User ID Out: When the user is successfully authorized, the user ID “2” is output through the Weigand port.  ※For Wiegand connection, see “6.4.7 Connection Wiegand.” ※Standard 26Bit Format is used for Wiegand In/Out format. The setting can be changed using the dedicated PC software. Use   /  buttons to select Wiegand and press OK.
 46   In case of TCP/IP     .                       ※IP Address/Gateway/Subnet Mask Setup: If DHCP is used, the values for  IP address, gateway, and subnet mask are automatically assigned. Otherwise, set DHCP  to Not Use and enter the corresponding values.  (When the right arrow is pressed, “.” is entered while the left arrow deletes characters  one by one.)  Server: To directly connect the server of the dedicated PC software that enables  monitoring and setting the terminal, use Server for its setup and enter the values for  IP address and port number. (Refer to the dedicated PC software manual.)  TCP/IP Port, Server Port: Should be the same values defined in the dedicated  PC software. It is recommended to set the TCP/IP port to “1471” and Server to “1480.” (When the port number is modified as you want, TCP/IP communication may not be active.)  When you exit before finishing the TCP/IP setting, the change is not stored so proceed with the settings until the message “Completed” appears. Item TCP/IP In/Out Use /  ◀▶buttons to set whether or not to use DHCP and press OK. DHCP Not Use TCP/IP IP Address 192.168.1.35 TCP/IP Gateway 192.168.1.10 TCP/IP Subnet Mask 255.255.255.0 TCP/IP ※It directly connects to the server for the dedicated PC software without using DHCP.Server Use TCP/IP Server IP 192.168.1.30 TCP/IP Server Port 1480 TCP/IP Port 1471 TCP/IP The completion message window appears.  Completed  100Base-T Support Not Support TCP/IP Use   /   buttons to set whether or not to support 100Base-T and press OK. Use   /  buttons to select the TCP/IP and press OK. Enter IP address and press OK. Enter Gateway using numeric and arrow button and press OK. Enter IP address using numeric and arrow button and press OK. Enter Port and press OK. Use   /  buttons to select the Use and press OK. Enter Server Port and press OK. Enter Server IP address using numeric and arrow button and press OK.
 47 4.3 System 1. Use  /   buttons to select the Device ( ) icon and press OK.   2. Use  /   buttons to select the System ( ) icon and press OK.    3. Use  /   buttons to select any of Information, Factory Default, Delete All Log, Delete User DB, and Language and press OK.  In case of Information                         Device System ItemInformation System Item Log Information Use   /  buttons to select Not Use and press OK.Filter Not Use Log The entire logs appear. (Use   /   buttons to see the previous/next logs.) 6/18 16:21(1) Set Time 6/18 14:20(3) Delete OKUse   /  buttons to select Log and press OK. Use   /  buttons to select Use and press OK. Filter Use Log UserAll Filter Use   /  buttons to select any of All and Select ID and press OK. Use   /  buttons to select any of All and Specify Date and press OK. The log filtering result appears on the screen. (Use   /   buttons to see the previous/next logs.) 6/18 14:20(3) Delete OK 6/18 13:46(3) Enroll OKUse   /   buttons to select the event type and press OK. *All/Success/Failure/In/Out/ System DateAll Filter Event All Filter ※ Filter - Not Use: Displays all. - Use: Only the specified log  is displayed. (ID/Date/Event Type)  ※When the date is specified, the logs occurred earlier than the specified date appear.
 48    In case of Information — Continued                       In case of Factory Default         ※In case of Initialize, the settings are deleted but the log data and user DB are not  deleted.   Use   /  buttons to select Num. Of User and press OK. The version of the firmware appears. Item Num. Of User Information Item Firmware Ver. Information UserTemplates 6/10000 4/5000Firmware Ver.V1.0_081127 Information Use   /  buttons to select Firmware Ver. and press OK. The version of the hardware appears.   Item Hardware Ver. Information Hardware Ver.11563(Rev.C) Information Use   /  buttons to select Hardware Ver. and press OK. The number of current users and the number of fingerprints enrolled appear. Item Factory Default System Use   /  buttons to select Factory Default and press OK. Use   /  buttons to determine whether or not to initialize it. *Cancel/ Initialize Initialize?Initialize Factory Default In case of Initialize, the message Initialized appears. Initialized
 49  In case of Delete All Log          ※In this case, all users’ in/out data are deleted and they cannot be recovered.   In case of Delete User DB           ※In this case, the users’ DB is completely deleted so you must immediately  register the initial administrator (see 1.4.1). ※When the user DB is deleted, it cannot be recovered.    In case of Language           In case of Delete, the message Deletion appears. Use   /  buttons to select Delete All Log and press OK. Use   /  buttons to determine whether or not to delete them. *Cancel/ Delete Item Delete All Log System Delete?Delete Delete All LogDeletionItem Delete User DB System In case of Delete, the message Deletion appears. Use   /  buttons to select Delete User DB and press OK. Use   /  buttons to determine whether or not to delete the user DB. *Cancel/Delete Delete?Delete Delete User DB DeletionUse   /  buttons to select Language and press OK. Use   /  buttons to select the language. * English/ Korean Press OK.Item Language System ItemEnglish Language
 50    In case of Wallpaper           ※Types - Type1: Only the time appears on the wallpaper screen. - Type2: The number of users and TCP/IP connection status appears  on the wallpaper screen.   In case of (8/5000) U - Eight people are registered among 5000  (number of people that can be registered) and it is unlinked.        Characters on the Type2 wallpaper - U: Unlinked (LAN is not connected.) - D: Disconnected (LAN is connected but TCP/IP communication is not active.) - C: Connected (LAN is connected and TCP/IP communication is active.)     Use /  buttons to ◀▶select Wallpaper and press OK. Use /  buttons to ◀▶select the type and press OK. *Type1/Type2 Item Wallpaper System Wallpaper Type1 System BioLite Net 10:33:02 Type1 BioLite Net10:33:02(8/5000) U Type2
 51 5. Attendance Management 5.1 Operating environment When an event (attendance, leaving, return, and outside duty) is received from the terminal, it is reported to the server of the dedicated PC software. You can create a report from the events stored in the server. With the dedicated PC software, you can also define new event other than the above-mentioned basic events and apply it to the report.  In case of basic events provided, each event causes the door to open. You can configure the settings according to the environment through the dedicated PC software.                        Event
 52 5.2  Setup for attendance management  1. Use   /   buttons to select the Device ( ) icon and press OK.   2. Use   /   buttons to select the Authorization () icon and press OK.   3. Use   /   buttons to select the Operation Mode and press OK.   4. Use   /   buttons to select the Time Attendance and press OK.   5. Use   /   buttons to select the Operation Mode of Time Attendance and press OK.    Operation modes※: *Key Input/Fixed/Manual/Auto/Not Use - Key Input: In usual time, the function is inactive. When ◀/▶ buttons are pressed,  you can select the attendance status. When a user authorization is successful, the selected attendance log is recorded. - Fixed: A specific attendance status continues. When a user authorization is successful,  the corresponding log is recorded. - Manual: The active attendance status appears on the screen and it can be changed  using ◀/▶ buttons. Once it is changed, the status continues until another  selection is made. Every authorization success makes the log recorded. - Auto: The active attendance status appears on the screen. Fore each time zone,  the active attendance statuses are fixed.  - Not Use: The function is not available.   Item Time Attendance Operation Mode Time Attendance Key Input Operation Mode Authorization Device Item Operation Mode Authorization
 53 5.3 Operation modes  5.3.1 Key Input When the operation mode is set to “Key Input,” this mode is used.                 5.3.2 Manual When the operation mode is set to “Manual”, this mode is used.  In case of Manual              The door opens with a confirmation message. ID: 8 In Select the desired event and perform user authorization. BioLite Net 10:33:02 Move to the desired event by using   /  buttons. Select In Type The desired event appears. BioLite Net 10:33:02 Move to the desired event by using   /  buttons. In 08:30:43 12/01/2008
 54   In case of Manual         ※Manual: It is convenient to those who need to change an event type manually everytime they             enter or leave.are in and out...   5.3.2 Auto When the operation mode is set to “Auto,” this mode is used. This mode can set the corresponding time zone for each attendance event through the dedicated PC software. Then the fixed event is set for the corresponding time zone.  In case of Auto         Auto※: While the event type and time zone are set through the dedicated  PC software, you can totally use this mode for all the users who are  entering or leaving.   The Users identify the card or fingerprint according to the authorization method. In 08:30:43 12/01/2008 The door opens with a confirmation message. ID: 8InThe users identify the card or fingerprint according to the authorization method. Out 18:35:55 12/01/2008 The door opens with a confirmation message. ID: 8OutThe event for the corresponding time zone appears.
 55 5.3.3 Fixed When the operation mode is set to “Fixed,” this mode is used. This mode is used after fixing the event through the dedicated PC software if required. In this case, the setting can be changed only through the dedicated PC software and you cannot change the attendance event through the terminal.           ※ Fixed: This mode is available only when the desired event is set for all the users  who are entering or leaving.          The users identify the card or fingerprint according to the authorization method. Out 18:35:55 12/01/2008 The door opens with a confirmation message. ID: 8OutThe preset event appears.
 56 6. FAQ 6.1 Error messages  Error Message  Description !Not Administrator  A normal user tries to enter the menu. !Not Authorized  The fingerprint authentication for the administrator fails when entering the menu. !Device Locked  The device is locked because the case has been open. !Failed  The number of users exceeds 5000, so you cannot enroll more users. !No Log  There is no log data. !Unknown Finger  The entered fingerprint for entering the menu or editing/deleting a user data does not exist. !Cannot Change A template already exists when you want to change the template format. !Failed  The user ID to delete does not exist. !ID In Use  The user ID to enroll already exists. !Unknown ID  The user ID that does not exist in the device is entered. !Wrong PIN  The entered password for authentication is not matched the enrolled one. !Invalid Value  An invalid value is entered. !Mode Error The authorization mode is different from the setting. !Not Matched The entered fingerprint or password is not matched to the enrolled one. - In case of fingerprint entry, the entered two fingerprints of the same finger are different. !Time Out The fingerprint data is not entered while the sensor is active. !Not Recognizable  The fingerprint data cannot be extracted due to wrong finger input. !Duplicated Time  The time zone is duplicated. !Duplicate Finger  When enrolling a user fingerprint, the fingerprint that has been input already exists in the device (when checking the duplicated case). !Access Restricted  The authentication trial happens except for the allowed time zone. !No Card You tried authorization with a unregistered card.
 57 6.2 Troubleshooting  Category  Trouble  Solution Power The power is supplied but the device does not operate. - When the device is disconnected from the bracket, it may not work when using the tamper switch. - Check the adapter or power cable. Password The password is lost.  - Enter the queried password after contacting the administrator in case of a normal user. - When the administrator password is lost, contact with the installation agency.The locked door is not open after entering the password and pressing OK. - Check whether the correct password is input.   - Check whether you have changed the password recently. - If you cannot find the password, contact the administrator.Fingerprint The fingerprint has been enrolled but its recognition encounters an error. - BioLite Net has the technology of Suprema that won the first award in FVC2004 and FVC2006 because it has world number one quality in recognition. - For better performance in fingerprint recognition, correct registration is a must. - Enroll the fingerprint again after seeing   “1.4 Methods for fingerprint input” - The recognition rate may vary due to the characteristic of each finger so enroll the fingerprint of another finger. It was good at recognizing fingerprints but suddenly it fails in recognition. - Check whether the finger or the sensor is covered with sweat, moisture, or dust. - In case the fingerprint has any damage, the device may consider it as the one of wrong person. - Wipe the finger or sensor with a dry cloth and retry. - When the fingerprint is so dry, blow your steam of breath into it and retry.Door lock Even if you close the door, the door is not locked. - The electric lock failure is most likely to happen. Check it after contacting the installation agency.   Time The time is not correct.  - BioLite Net has an embedded battery but it can be discharged by a long time use. Accordingly the time may not be correct. Correct the time after seeing “3.1 Date, Time.” TCP/IP The terminal data is not found by the dedicated PC software. - Check the connection status after setting on the terminal like Terminal > System > Wallpaper > Type2.  - When U is displayed: Check the LAN connection status.   - When D is displayed: Check the IP address. If you set like Terminal > In/Out -> TCP/IP -> DHCP Not Use, the current IP address appears. If you use DHCP, the actual address received from the DHCP server appears. If the IP address is set correctly, check the port number. Administrator connection The administrator mode cannot be entered because of losing the administrator password or resignation. - BioLite Net allows the administrator to give access rights so only the administrator can enter the menu. - When you have no choice but to enter the administrator menu, you can be granted an administrator password after following the predefined procedure. (Contact with the installation agency.)
 58 6.3 Usage summary  ※ It provides the mainly used functions. ※  button: Used to select the desired function.  Function  Method for setting(Sequentially perform the following items.) Initial administrator registration  Enter ID   Enter password    Enter password again Date & time setting  Select Screen, Sound ( ) icon   Select Date, Time ( ) icon   Enter date   Enter time User registration  Select User ( ) icon   Select Enroll () icon   Enter ID   Select General or Administrator in Level    Enter fingerprint or PIN User password modification Select User () icon   Select Edit () icon   Enter ID or fingerprint   Select PIN   Enter the desired password   Enter it again User fingerprint modification Select User () icon   Select Edit ( ) icon   Enter ID or fingerprint   Select Fingerprint   Enter the fingerprint of the user  Enter it again User authorization method modification Select User () icon   Select Enroll ( ) icon   Enter ID or fingerprint   Select Operation Mode   Select an authorization method  User deletion  Select User () icon   Select Delete ( ) icon    Enter ID or fingerprint to delete All user deletion  Select Device () icon   Select System () icon   Select Delete User DB  Select Delete Initialization (Environment settings deletion) Select Device ( ) icon   Select System ( ) icon   Select Factory Default  Select Initialize
 59 6.4 System Installation 6.4.1 Cable specifications           Type  No.  Name  Color Switch & Wiegand 1  SWIN0  Purple 2  GND  Gray 3  SWIN1  Brown 4  GND  Gray 5  W-DATA0  Orange 6  W-DATA1  White 7  W-GND  Black Network 8  ERX -  Yellow 9  ERX +  Blue 10  ETX -  Orange 11  ETX +  Pink Relay 12  Relay Normal Close  Orange (White String) 13  Relay Common  Green (White String) 14  Relay Normal Open  Gray (White String) Power & RS485 15  Power 12V  Red 16  Power Ground  Black 17  RS485 Ground  White (Black String) 18  RS485 +  Blue (Black String) 19  RS485 -  Yellow (Black String)
 60 6.4.2  Installing the bracket  1. Fix the bracket to the place where BioLite Net is to be installed using the fixing screws.            2. Install BioLite Net on the bracket.            3. Fix BioLite Net and the wall mount bracket by rotating the star-shape screw by the hexagonal wrench.          If the installation place is on concrete, drill holes, insert knife blocks into the holes, and fix them by using fixing screws. The extension bracket (Option) is provided for wiring aid according to the installation environment. Remove the basic bracket on the body for use of this bracket
 61 6.4.3  Connecting Power & RS-485            ※RS-485 is used for connecting to another device  (e.g. PC, BioStation, BioEntry Plus, BioLite Net, Secure I/O, etc.).        6.4.4  Connecting the switch               For power supply, use a product of DC 12V (± 10%) and minimum 500mA. To share the power adapter with another device, the required current sum of terminal (500mA) and another device must not exceed the current capacity.
 62 6.4.5  Connecting the relay 1. Fail safe lock          2. Fail secure lock          3. Automatic door
 63 6.4.6 Connecting Network               6.4.7 Connecting Wiegand             When BioLite Net is used for Wiegand output device  When BioLite Net is used for Wiegand input device
 64  6.4.8 Electrical specifications  Type  Name  Min.  Typ.  Max. Notes Power  Voltage (V)  10.8  12  13.2  Use regulated DC power adaptor only Current (mA)  -   250   Switch Input VIH (V)  -  TBD  -   VIL (V)  -  TBD     Pull-up resistance ( ) -  4.7k  -  The input ports are pulled up with 4.7k resistors Relay  Switching capacity (A) -  -  1 0.3 30V DC 125V AC Switching power (resistive) -  -  30W 37.5VADC AC Switching voltage (V) -  -  110 125 DC AC
 65 6.5 Specifications  Item  Specification CPU  400MHz DSP Fingerprint sensor  500dpi optical sensor   User capacity  5000 users (2 fingerprints per user) Matching speed  Less than 1 second Operation mode  Fingerprint, Password, Fingerprint + Password, Card   IP rate  IP65 Class Internal relay  Deadbolt, EM lock, door strike, automatic door   TTL I/O  2 inputs for exit switch and door sensor Wiegand In/Out  1 Port (Wiegand Input or Wiegand Output is used according to the configuration.) LCD  128 x 64 Graphic LCD (Monochrome) Keypad  3x4 keypad, 3 navigation keys Log capacity  50,000 events Rated Voltage DC 12V (Min. 500mA and above) (When sharing the power with a device such as electric door lock, enough power is required considering the power requirement for the connected device.) Supportable Cards  BioLite Net Model(BLN-OC)   - 13.56MHz Mifare Classic 1K, 4K Card (Read/Write)   - 13.56MHz ISO 14443A compatible Card (CSN Read) BioLite Net EMProx Model(BLR-OC)   - 125KHz EM4100 compatible Card (Read) Size  60 x 185 x 40 mm (Width x Height x Depth) Certified  KCC, CE, FCC
 66 Mechanical Specifications
 67 6.6 FCC Notice                        Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment  Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ·  1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to     which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help.

Navigation menu