BioEntry WIP Based Fingerprint Access ControlInstallation Guide(Ver01)(Ver0.1)www.suprema.co.kr
BioEntry WSafety precautions  3Basics of fingerprint recognition 5How to place a finger  6dContentsProduct Contents  8Front Side  10Bottom and Back Side  11Product Dimension  12Cables and Connectors  13Installation of Wall-mount Bracket  14Power Connection  15Ethernet Connection16Ethernet Connection 16RS485 Connection  18Relay Connection  20Digital Input Connection  23Wiegand Output  25Network Default Setting                                                        26              Installation Reference  27Electrical Specification30Electrical Specification 30Troubleshooting 31Device cleaning  32FCC Rules 33Sifii 342ⒸCopyright 2007 Suprema Inc.Specifications                                                                          34
BioEntry WSafety precautionsThe list below is to keep user’s safety and prevent any loss. Please read carefully before use.Do not install the device in a  Do not place a magnet near the pr Do not place the device next to place subject to direct sun light, humidity, dust or soot. oduct. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device.heating equipments.Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. 3ⒸCopyright 2007 Suprema Inc.
BioEntry WSafety precautionsThe list below is to keep user’s safety and prevent any loss. Please read carefully before use.Do not drop the device.  Do not damage the device. Do not disassemble, repair oralter the device.Do not let children touch the device without supervision.Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem. 4ⒸCopyright 2007 Suprema Inc.
BioEntry WBasics of fingerprint recognitionWhat is fingerprint recognition?zFingerprint is an individual’s own biometric information and does not change throughout his/her life. gp g gFingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information.zFree from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards. Process of fingerprint recognitionzFingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys and finger recognition makes use of such originality and uniqueness of these patternsand finger recognition makes use of such originality and uniqueness of these patterns.zFingerprint sensor generates 2-dimentional fingerprint image using different technology. According to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal. zFingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioStation and used for identificationFingerprint templates are saved inside the memory of BioStation and used for identification. Secure way to protect personal information zTo avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric dataimpossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint.5ⒸCopyright 2007 Suprema Inc.
BioEntry WHow to place a fingerSuprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal fffingerprint recognition performance.Select a finger to enrollzIt is recommended to use an index finger or a middle finger. zThumb ring or little finger is relatively more difficult to place in a correct positionzThumb, ring or little finger is relatively more difficult to place in a correct position.How to place a finger on a sensorPl fi h th t it l t l th ith i t tzPlace a finger such that it completely covers the sensor area with maximum contact. zPlace core part of a fingerprint to the center of a sensor.People tend to place upper part of a finger.The core of a fingerprint is a center where the spiral of ridges is dense. Usually core of fingerprint is the opposite side of the lower part of a nailUsually core of fingerprint is the opposite side of the lower part of a nail. Place a finger such that the bottom end of a nail is located at the center of a sensor.zIf a finger is placed as in the right picture, only a small area of a finger is captured. So it is recommended to place a finger as shown in the left picture. 6ⒸCopyright 2007 Suprema Inc.
BioEntry WHow to place a fingerTips for different fingerprint conditionszSuprema’s fingerprint products are designed to scan fingerprint smoothly regardless of the pgpp g gp ygconditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips. If a finger is stained with sweat or water, scan after wiping moisture off.If a finger is covered with dust or impurities, scan after wiping them off.If a finger is way too dry place after blowing warm breath on the finger tipIf a finger is way too dry, place after blowing warm breath on the finger tip.Tips for fingerprint enrollmentzIn fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place a finger correctly with care. zIn case of low acceptance ratio the following actions are recommendedzIn case of low acceptance ratio, the following actions are recommended.Delete the enrolled fingerprint and re-enroll the finger.Enroll the same fingerprint additionally.Try another finger if a finger is not easy to enroll due to scar or worn-out.zFor the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is recommended to enroll more than two fingers per user.7ⒸCopyright 2007 Suprema Inc.
BioEntry WProduct ContentsBasic ContentsWall mounting screws–2eaStar-shaped screwsWall mounting screws 2 eaStarshaped screwsStar-shaped small wrench Software CDBioEntry W Wall-mounting metal bracket8ⒸCopyright 2007 Suprema Inc.
BioEntry WProduct ContentsOptional accessoriesUSB fingerprint scanner for enrollment on PC12V power adaptor Plastic standSecure I/O9ⒸCopyright 2007 Suprema Inc.
BioEntry WFrontFront SideLED Status per ColorzGreen : Authorization SuccessRd Ath i ti FilLEDDisplay current status using seven different colorsRF card reading partPlace an RF card over the picturezRed : Authorization FailzPink : On Processing zFlicker Blue/Sky-Blue Color per 2sec : NormalFingerprint sensing partPlace a finger on a sensor fzFlicker Red/Pink Color per 2sec : LockedzFlicker Blue/Red Color per 2sec : Initialized Time  due to the Internal Battery Dischargesurface zFlicker Blue/Yellow Color per 2sec : DHCP FailzFlicker Red Color per 2sec : Failed. Please contact to your distributor or SupremazFlicker Yellow Color per 2sec : Waiting InputzFlicker Yellow Color per 1sec : Receiving IP Address from DHCP server10ⒸCopyright 2007 Suprema Inc.
BioEntry WBottom and Back SideStar-shaped screw hole for fixing a body to a metal bracketwiegand input or wiegand outputpower and RS485ethernet (TCP/IP)ethernet (TCP/IP)digital input and relay outputNetwork Indicate LEDit hNt kR tswitch : Network Reset(Refer to “Network Default Setting” pages for details)11ⒸCopyright 2007 Suprema Inc.
BioEntry WProduct Dimension504440504440172 157172Metal BracketFront Side(unit : mm)12ⒸCopyright 2007 Suprema Inc.
BioEntry WCables( all cables use the shielded cables)  13ⒸCopyright 2007 Suprema Inc.
BioEntry WInstallation of Wall-mount BracketFix wall mount bracket on a wall using wall mounting screwsHook BioEntry W on the wall mount bracketscrewsWall mounting screwsFix BioEntry W and wall mounting bracket using a star shape screw.Star-shaped screw14ⒸCopyright 2007 Suprema Inc.Star-shaped wrench
BioEntry WPower ConnectionUPS(optional)TRX(Yellow/White)TRX+ (Blue/White)Signal GND (Black/White)Power GND (Black)Power 12V (Red)RS-485DCPower supplyBioEntry WTRX-(Yellow/White)Recommended power supply12V±10% t l t 500 Az12V ±10%, at least 500mA.zComply with standard IEC/EN 60950-1.zTo share the power with other devices, use a power supply with higher current ratings.15ⒸCopyright 2007 Suprema Inc.
BioEntry WEthernet Connection16ⒸCopyright 2007 Suprema Inc.
BioEntry WEthernet Connection (Direct connection with PC)To connect BioEntry W with a PC directly, connect both devices with a straight CAT-5 cable. As the BioEntry W supports auto MDI/MDIX feature, it is not necessary to use a crossover type cable.17ⒸCopyright 2007 Suprema Inc.
BioEntry WRS485 Connection for Host Communication(Black/White)(Black/White)(Blue/White)(Yellow/White)W(Black/White)(Blue/White)(Yellow/White)W18ⒸCopyright 2007 Suprema Inc.
BioEntry WRS485 Connection for Secure I/O(Black/White)(Blue/White)(Y ll /Whit )(Black/White)(Blue/White)(Yellow/White)(Yellow/White)WW(Yellow/White)Max number of deviceszMaximum numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry W) 19ⒸCopyright 2007 Suprema Inc.and four(4) Secure I/Os
BioEntry WRelay Connection –Fail safe lock20ⒸCopyright 2007 Suprema Inc.
BioEntry WRelay Connection –Fail secure lock21ⒸCopyright 2007 Suprema Inc.
BioEntry WRelay Connection -Automatic doorRTE SwitchPresence DetectorAt tiDBioEntry W(7)NllO/NO(G/Whit)Automatic DoorDoor Controller(7) Normally Open / N.O. (Gray/White)(6) Common (GREEN/White)(5) Normally Closed / N.C. (Orange/White)22ⒸCopyright 2007 Suprema Inc.
BioEntry WDigital Input Connection (RTE, Door sensor)23ⒸCopyright 2007 Suprema Inc.
BioEntry WDigital Input Connection (Alarm, Emergency sw)BioEntry W(4) SW1 GND (Black/White)Switch #1 (1) SW0 Input (Purple)(2) SW0 GND (Black/White)(3) SW1 Input (Brown)()()Switch #224ⒸCopyright 2007 Suprema Inc.
BioEntry WWiegand Input/OutputWiegand Inputega d putWiegand Output25ⒸCopyright 2007 Suprema Inc.
BioEntry WNetwork Default SettingIn case of forgetting network setting of BioEntry W (TCP/IP or RS-485 setting) during installation or using BioEntry W, user can initialize network setting (TCP/IP or RS-485 setting) by using DIP SW installed on the back panel of BioEntry W. Please refer to the figures in below.How to initialize Network Settinggz1. Turn On BioEntry W power.z2. Please push the Switch (Please refer to Fig.1)2. Please push the Switch (Please refer to Fig.1)z3. After turning on BioEntry Plus power, user can modify TCP/IP or RS-485 setting what user wants. zNetwork Default Settingz4Please modify TCP/IP or RS-485 setting and save itzNetwork Default Setting- TCP/IP Address : 192.168.0.1- Not checked “Use Server”- RS-485 : PC Connection, 115200bps4. Please modify TCP/IP or RS485 setting and save it.z4. Please make DIP SW #2 “OFF” (Please refer to Fig.2)z5 After recyclingBioEntryW power please check the26ⒸCopyright 2007 Suprema Inc.z5. After recycling BioEntryW power, please check the modified TCP/IP or RS-485 setting.
BioEntry WInstallation Reference 1 - Stand aloneDoor SensorDoor Lock Exit ButtonBioEntry WLANEnroll ScannerPCLAN27ⒸCopyright 2007 Suprema Inc.
BioEntry WInstallation Reference 2 –SecureRS485RS485Door SensorExit ButtonBioEntry WSecure I/ODoor LockEnroll ScannerPCLAN28ⒸCopyright 2007 Suprema Inc.
BioEntry WInstallation Reference 3 –NetworkDoor Zone 1 (Anti passback)RS485RS485RS485RS485BioStation BioEntry W BioEntry W Secure I/OLANPC SEllSPC ServerPC ClientEnroll ScannerBioStation Secure I/O BioEntry W Exit ButtonPC ClientPC ClientRS48529ⒸCopyright 2007 Suprema Inc.Door Zone 2 (Anti passback)
BioEntry WElectrical SpecificationMin. Typ. Max. NotesPowerVoltage (V) 10.8 12 13.2 Use regulated DC power adaptor onlyCurrent (mA) - 250Switch InputSwitch InputVIH (V) -TBD-VIL (V) -TBDPull-up resistance (Ω)- 4.7k - The input ports are pulled up with 4.7k resistorsTTL/Wiegand OutputVOH (V) -5-VOL (V) -0.8-Pllit (Ω)47kThe outputs ports are open drain type, pulled up with 4.7k resistorsPull-up resistance (Ω)-4.7k-The outputs ports are open drain type, pulled up with 4.7k resistors internallyRelaySwitching capacity (A) --10.330V DC125V ACSwitching power (resistive) --30W37.5VADCACSwitching voltage (V) --110125DCAC30ⒸCopyright 2007 Suprema Inc.
BioEntry WTroubleshootingFingerprint can not be read well or it takes too long.zCheck whether a finger or fingerprint sensor is stained with sweat, water, or dustggp ,,zRetry after wiping off finger and fingerprint sensor with dry towel.zIf a fingerprint is way too dry, blow on the finger and retry.Fingerprint is entered but authorization keeps failing.zCheck whether the user is restricted by door zone or time zonezCheck whether the user is restricted by door zone or time zone. zInquire of administrator whether the enrolled fingerprint has been deleted frin the device for some reason.Authorized but door is not opened.zCheck whether the time is set as lock timezCheck whether the time is set as lock time. zCheck whether an antipass back mode is in use. In antipass back mode, only who entered can exit. Device doesn’t operate though power is connected.zCheck whether a device and a bracket is well connected to each other. If not, a tamper switch is activated and the device doesn’tworkactivated and the device doesn t work. 31ⒸCopyright 2007 Suprema Inc.
BioEntry WDevice cleaningWipe out machine surface with dry towel or cloth.In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with case t e e s dust o pu t es o t e se so o t e oStat o , pe o t e su ace tdry towel.Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and fingerprint can’t be entered. 32ⒸCopyright 2007 Suprema Inc.
BioEntry WFCC RulesCaution zChanges or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment.pypqpzRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPEzDISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONSWarning zThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Information to User zThis equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and if not installed and used in accordance with the instructions may causeand, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guaranteee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:1. Reorient / Relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.4.Consult the dealer or an experienced radio/TV technician for help33ⒸCopyright 2007 Suprema Inc.4.Consult the dealer or an experienced radio/TV technician for help
BioEntry WSpecificationsItem SpecificationCPU400MH DSPCPU400MHz DSPFingerprint sensor 500dpi Optical / Capacitive sensorUser capacity 5000 users (10,000 templates)Log capacity 50,000 eventsMatching speed Less than 1 secondOperation mode Fingerprint, RF Card, RF card + FingerprintNetwork Interface TCP/IP, RS485 Internal relayDeadbolt EM lock door strike automatic doorInternal relayDeadbolt, EM lock, door strike, automatic door TTL I/O 2 inputs for exit switch and door sensorWiegand In/Out 1 Port (Wiegand Input or Wiegand Output is used according to the configuration.)Sound and Interface Multi-color LED and multi-tone buzzerRated VoltageDC 12V (Min. 500mA and above)(When sharing the power with a device such as electric door lock, enough power is required considering the power requirement for the connected device.)Card option 13.56MHz Mifare CardSize 50 x 160 x 37 mm (Width x Height x Depth)Certified KCC, CE, FCC34ⒸCopyright 2007 Suprema Inc.
Suprema Inc.16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 KoreaE-mail  :  support@supremainc.comWebsite : www supremainc comWebsite  :  www.supremainc.comFunctions and specifications of the product are subject to changes without notice due to quality enhancement or function update For any inquiry on the product please contactSuprema Incenhancement or function update. For any inquiry on the product, please contact Suprema Inc.