BioEntry  WImportant Safety Information Carefully review the information within the user manual before installing/operating the device.Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to any person(s) or property associated with the device.WarningFailure to heed these warnings may lead to serious injury or even death!CautionFailure to heed these cautions may lead to minor injury or damage the device.InstallationDo not install the device near heat sources such as radiators, heat registers, and stoves.InstallationDo not leave cables (especially power cables) exposed to the outer environment.Copyright 2007 Suprema Inc. 2heat registers, and stoves.Do not install the device near areas of large electromagnetic interference.the outer environment.Do not install the device near objects with a strong magnetic field such as magnets, computer monitors (especially CRT), TV screens and speakers.UsageDo not disassemble, repair or reconstruct the device.Contact your nearest Suprema dealer for technical support.Only use the device its intended use.UsageDo not drop or apply any physical shock/impact to the device.Regularly clean the product with a soft dry cloth; avoid benzene or alcohol.
BioEntry  WContents About Fingerprint Recognition 4How to Enroll a Fingerprint on the Device 5Components 7Product Description 9Dimensions  11Cable Specifications 12Installation 13Copyright 2007 Suprema Inc. 3Installation 13System Configurations 14Connections 17Resetting Network Settings  28Electrical Specifications 29Product Specifications 30Troubleshooting 31Precautions for Device cleaning 32FCC Rules 33
BioEntry  WAbout Fingerprint RecognitionWhat is a fingerprint?Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards.What is fingerprint recognition?Fingerprints consist of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is thehollow between two ridges. Each individual has unique patterns of ridges and valleys; fingerprint recognition makes use of these differences to differentiate between individuals.Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or Copyright 2007 Suprema Inc. 4Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioEntry W, and used for identification. Suprema’s Personal Information Protection TechnologyTo avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint.
BioEntry  WHow to Enroll a Fingerprint on the DeviceFingerprint EnrollmentIt is recommended to enroll the index or middle finger.The thumb, ring or little finger are generally more difficult to position properly.How to place a finger on a sensorSuprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint condition or positioning. However pay careful attention to the following instructions to maximize the performance of the device.Copyright 2007 Suprema Inc. 5How to place a finger on a sensorFully cover or provide maximum contact to the surface of the sensor with the desired finger. People tend to place the tip of a finger on the sensor; this will only provide a small area of the finger to be captured and will result in poor performance.Place the core of the fingerprint near the center of the sensor. This will ensure a good template will be created. The core of a fingerprint is a center where the spiral of ridges is most dense.
BioEntry  WHow to Enroll a Fingerprint on the DeviceFingerprint Enrollment PrecautionsOperational WarningsIf a finger is wet or too moist, wipe off the moisture then try the scan again.If a finger is covered with dust or impurities, clean the finger then try the scan again.If a finger is dry, breathe warm air onto the finger then try the scan again.Solving Authentication DifficultiesDelete then Re-enroll the finger.Enroll the same finger multiple times.Copyright 2007 Suprema Inc. 6Enroll the same finger multiple times.Try a different finger with a more vivid fingerprint.Enroll various fingers for each user.
BioEntry  WComponentsBasic ComponentsWall Mount Screws (2) Main Unit Mounting Screws (2)Copyright 2007 Suprema Inc. 7BioEntry WWall Mounting bracket (1) Software CD (1)
BioEntry  WComponentsOptional AccessoriesCopyright 2007 Suprema Inc. 8USB Fingerprint Scanner12VDC Power Adaptor Plastic StandSecure I/O
BioEntry  WProduct DescriptionRFID ScannerPlace an RFID card over the LEDDisplays the current status withvarious colors.LED Device StatusGreen Successful AuthenticationRed Failed AuthenticationPink ProcessingFlicker Blue/Sky-Blue Color per 2secStandard OperationFrontCopyright 2007 Suprema Inc. 9Place an RFID card over the scanner.Color per 2secStandard OperationFlicker Red/Pink Color per 2sec Device LockedFlicker Blue/Red Color per 2sec Discharged Internal BatteryFlicker Blue/Yellow Color per 2secUnable to Acquire an IP Address from the DHCP Server.Flicker Red Color per 2sec Unit Malfunction. Contact Your Suprema Dealer/Distributor.Flicker Yellow Color per 2sec Waiting for an InputFlicker Yellow Color per 1secRequesting IP Address from the DHCP Server.Fingerprint Sensor Place a finger on the surface of the   sensor.
BioEntry  WProduct DescriptionRear and Bottom CablesWiegand Input/Output CablesPower CablesRS485 CablesEthernet ConnectorInput CablesRelay CablesCopyright 2007 Suprema Inc. 10Relay CablesLEDNetwork Status LEDNetwork Reset Switch See "Resetting Network Settings (page 28)" for more details.Star-shaped screw hole for fixing a body to a metal bracket
BioEntry  WDimensions 50 mm 40 mm44 mmBioEntry W Wall Mounting Bracket Copyright 2007 Suprema Inc. 11172 mm 157 mm 172 mm
BioEntry  WCable Specifications1 SWIN1 BROWN2 SWIN0 PURPLE3 ETH TXP WHITE4 ETH TXN ORANGE5 ETH RXP BLACK6 ETH RXN YELLOW7 POWER IN RED8 POWER GND BLACK9PoE VB2 BLUECopyright 2007 Suprema Inc. 129PoE VB2 BROWN10PoE VB1 REDPoE VB1 GREEN11 485 TRXN YELLOW/WHITE STRIPE12 485 TRXP BLUE/WHITE STRIPE13 485 GND BLACK/WHITE STRIPE14 WIEGAND GND WHITE/BLACK STRIPE15 WIEGAND D1 WHITE16 WIEGAND D0 GREEN17 NC PINK18 RELAY NC ORANGE/WHITE STRIPE19 RELAY COM GREEN/WHITE STRIPE20 RELAY NO GRAY/WHITE STRIPE
BioEntry  WInstallation1. Fix the wall mounting bracket on a wall by using wall mounting screws.2. Hook the device on the wall mount bracket.3. Fix the device to the wall mounting bracket using thestar-shaped screws.Star-shaped screwCopyright 2007 Suprema Inc. 13Wall Mount Screwsscrew
BioEntry  WSystem ConfigurationsDoor LockDoor SensorExit ButtonStandardCopyright 2007 Suprema Inc. 14Door LockExit ButtonPCLANBioEntry WUSB Fingerprint Scanner
BioEntry  WSystem ConfigurationsRS485Door SensorSecure (Secure I/O)Copyright 2007 Suprema Inc. 15Exit ButtonPCLANBioEntry WSecure I/ODoor LockUSB Fingerprint Scanner
BioEntry  WNetworkDoor Zone 1 (Anti-passback)Secure I/ORS485 RS485System ConfigurationsFaceStationCopyright 2007 Suprema Inc. 16Door Zone 2 (Anti-passback)BioEntry W BioEntry WLANSecure I/O BioEntry W Exit ButtonPC ServerPC ClientPC ClientRS485USB Fingerprint ScannerFaceStation
BioEntry  WPower Connection ConnectionsCopyright 2007 Suprema Inc. 17Recommended Power Specifications12V  10%, at least 500mA.Comply with standard IEC/EN 60950-1.When sharing power with other devices, use a power supply with a higher current rating.UPS(Optional)DC Power Supply
BioEntry  WConnectionsEthernet Connection (Connection with HUB)The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet terminal.  PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power Sourcing Equipment) satisfying the IEEE802.3af standard.Ethernet HubCopyright 2007 Suprema Inc. 18
BioEntry  WConnectionsEthernet Connection (Direct connection with PC)Use a standard CAT-5 cable to connect the device directly to a PC.BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary.Copyright 2007 Suprema Inc. 19
BioEntry  WConnectionsRS485 Connection for Host CommunicationGND -TRX+ TRX-RS232-485ConverterPower IN (Red)Power GND (Black)Signal GND (Black/White Stripe)TRX+ (Blue/White Stripe)TRX- (Yellow/White Stripe)BioEntry WCopyright 2007 Suprema Inc. 20NotesOnly the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converter’s manual.Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be necessary to lower the baudrates. The GND signal may be omitted if and only if the GND potential difference is less than  5V.Power IN (Red)Power GND (Black)Signal GND (Black/White Stripe)TRX+ (Blue/White Stripe)TRX- (Yellow/White Stripe)BioEntry W
BioEntry  WRS485 Connection for Secure I/OConnectionsPower IN (Red)Power GND (Black)Signal GND (Black/ White Stripe)TRX+ (Blue/ White Stripe)TRX- (Yellow/ White Stripe)BioEntry WPower IN (Red)Power GND (Black)Signal GND (Black/White Stripe)TRX+ (Blue/White Stripe)TRX- (Yellow/White Stripe)BioEntry WCopyright 2007 Suprema Inc. 21NotesFor bus termination, only the devices at both ends of the bus should be terminated.Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os.TRX GND -TRX+ TRX-Secure I/OTRX GND -TRX+ TRX-Secure I/O
BioEntry  WConnectionsRelay Connection – Fail safe lockBioEntry W(20) Relay NO (Gray/White Stripe)(19) Relay COM (Green/White Stripe)(18) Relay NC (Orange/White Stripe)Copyright 2007 Suprema Inc. 22Deadbolt /Door strike+            -DCPower supply
BioEntry  WConnectionsRelay Connection – Fail secure lockBioEntry W(20) Relay NO (Gray/White Stripe)(19) Relay COM (Green/White Stripe)(18) Relay NC (Orange/White Stripe)Copyright 2007 Suprema Inc. 23Deadbolt /Door strike+            -DCPower supply
BioEntry  WConnectionsRelay Connection - Automatic doorRTE SwitchPresenceDetectorCopyright 2007 Suprema Inc. 24RTE SwitchAutomaticDoorBioEntry W(20) Relay NO (Gray/White Stripe)(19) Relay COM (Green/White Stripe)(18) Relay NC (Orange/White Stripe)
BioEntry  WConnectionsDigital Input Connection (RTE/ Door sensor)BioEntry W(13)  485 GND (Black/White Stripe)Copyright 2007 Suprema Inc. 25(13)  485 GND (Black/White Stripe)(1)    Input 1 (Brown)(13)  485 GND (Black/White Stripe)(2)    Input 0 (Purple)Door StatusRequest TO Exit
BioEntry  WConnectionsDigital Input Connection (Alarm/ Emergency switch)BioEntry W(13)  485 GND (Black/White Stripe)Copyright 2007 Suprema Inc. 26(13)  485 GND (Black/White Stripe)(1)    Input 1 (Brown)(13)  485 GND (Black/White Stripe)(2)    Input 0 (Purple)Switch #1Switch #2
BioEntry  WWiegand InputConnectionsBioEntry W(14)  Wiegand GND (White/Black Stripe)(15)  Wiegand D1 (White)(16)  Wiegand D0 (Green)  RFID ReaderGNDWiegand D1Wiegand D0Copyright 2007 Suprema Inc. 27Wiegand OutputControllerGNDWiegand D1Wiegand D0BioEntry W(14)  Wiegand GND (White/Black Stripe)(15)  Wiegand D1 (White)(16)  Wiegand D0 (Green)
BioEntry  WResetting Network Settings In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the back panel of the device. Please refer to the figures as below.1. Turn on the device.2. Press and hold the network reset switch until the device turns off. (Then, the device will restart.)Network Default SettingCopyright 2007 Suprema Inc. 28TCP/IP Address : 192.168.0.1Not checked “Use Server”RS-485 : PC Connection, 115200bps3. Modify then save the TCP/IP or RS485 settings.4. Reboot the device. 5. Confirm the new settings.Network Reset Switch
BioEntry  WElectrical SpecificationsMin. Typ. Max. NotesPowerVoltage (V) 10.8 12 13.2 Use regulated DC power adaptor only.Current (mA) - 250Switch InputVIH (V) - TBD -VIL (V) - TBDPull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistors.Copyright 2007 Suprema Inc. 29TTL/Wiegand OutputVOH (V) - 5 -VOL (V) - 0.8 -Pull-up resistance (Ω) - 4.7k - The outputs ports are open drain type, pulled up with 4.7k resistors internally.RelaySwitching capacity (A) - - 10.330V DC125V ACSwitching power (resistive) - - 30W37.5VADCACSwitching voltage (V) - - 110125DCAC
BioEntry  WProduct SpecificationsSystemMax Users 5000 users (10,000 templates) [1:1 & 1:N]Log Capacity 50,000 logs CPU 533MHz DSPMemory 8MB Flash + 8MB RAMRF Options 125KHz HID PROXInterfacesTCP/IP, RS485, WiegandCopyright 2007 Suprema Inc. 30InterfacesTCP/IP, RS485, WiegandInput / Output 2 TTL Inputs, 1 Relay OutputPower 12VDC, PoE (Power over Ethernet) General DimensionsBioEntry W(W x H x D) 50 x 172 x 44 mmWall Bracket(W x H) 40 x 157 mm (screw joint included)
BioEntry  WTroubleshootingPlease contact your local dealer/distributor for support or contact Suprema at support@supremainc.com. Please submit the following information and we will coordinate support with your local dealer/distributor.Device modelF/W version of the deviceH/W version of the deviceDetailed information regarding the issueError messages / screenshots, if possibleContact information (Company, Name, Telephone, Email)Copyright 2007 Suprema Inc. 31Contact information (Company, Name, Telephone, Email)
BioEntry  WPrecautions for Device CleaningWipe out the device surface with dry towel or cloth.Use a soft dry towel when removing dust or impurities from the surface of the sensor.Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's ability to properly read a fingerprint.Copyright 2007 Suprema Inc. 32
BioEntry  WFCC Rules Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation. Information to User Copyright 2007 Suprema Inc. 33Information to User This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures: 1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help.