Part Number 062-0983-01 Rev C   page 3 - 2   Table of Contents   1. Wireless Ethernet Product Description    a. Overview of Spacelabs Wireless Networks ............................................................................     b. 90309 Option "W"....................................................................................................................     c. UCW – Z, 90367 and 90369 Option "Z" ..................................................................................     d. 90310 Option "A", "B", or “C” (Central, Master, or Slave interface unit) ................................     e. Technical description of operation .........................................................................................    f. Ethernet Interface Card  ..........................................................................................................        g. OEM radio card ......................................................................................................................     h. Understanding Signal Interference ........................................................................................    i. Coverage Area ........................................................................................................................     j. Possible Monitor and WNI Configurations ..............................................................................        k. Communication Limitations of the wireless network ..............................................................     l. Selecting Wireless Network Equipment Locations ..................................................................    m. Installation Hardware ............................................................................................................    n. Part Numbers .........................................................................................................................   2. Wireless Network Site Survey Procedure      a. Things to have before beginning the survey ...........................................................................       b. Things to know about the site before beginning ......................................................................       c. Actions Before the site survey: ................................................................................................       d. Performing a Wireless site survey:  .........................................................................................       e. Completing the site survey: .....................................................................................................   3. Post-Installation Verification and Troubleshooting       a. Acceptance Criteria ................................................................................................................    b. Troubleshooting with RangeLAN2 .........................................................................................     c. Troubleshooting with ULTRAVIEW-1030/ULTRAVIEW-1050 Site Survey screen ................    APPENDIX 1 - The RangeLAN2 PCMCIA Card ............................................................................     a. Installing and configuring the RangeLAN2  ............................................................................     b. Using the RangeLAN2 PCMCIA card for site survey  ............................................................   APPENDIX 2 - Microwave Leakage Measurements ....................................................................   1  1  2  2  2  3  4  5  6  8  10  10  12  13  15  17  17  17  17  18  20  22  22  22  25  26  26  29  33
1. Wireless Ethernet Product Description  a. Overview of Spacelabs Wireless Networks   Spacelabs wireless ethernet allows connection between a conventional wired ethernet network and a wireless (radio) ethernet network. This enables the two networks to function as one.  Wireless ethernet provides 1 to 5 outbound waveforms and numeric vital signs. The wireless ethernet option applies to the 90309-W PC Ranger, the 90367-Z Ultraview 1030, the 90369-Z Ultraview 1050, and the 90385-Z wireless Universal Clinical Workstation (UCW).  Wireless ethernet uses 2.4GHz two-way cellular radio communications to transmit and receive patient data.  Waveforms, alarms, numeric data, bed information and configuration messages can be transmitted from the bedside/transport monitor, “slave”, to the rest of the network through one Wireless Network Interface, “master”.  For ambulatory patients, an array of Wireless Network Interface devices is used to provide complete cellular coverage.  The Wireless Network Interface (WNI) serves as the wireless access point to the hardwired ethernet LAN.  With optional interactive networking, bed to bed access is possible.  As shown below, wireless monitors use a radio link to communicate with a Wireless Network Interface (WNI). The wireless monitors each synchronize their communications with one WNI, referred to as a “master”. The WNI completes the ethernet link to the hard-wired network.   21 FEB 1994HELP?MONITORSETUPNORMALSCREENRX%4SPECIALFUNCTIONSRECORD%XTONE RESETALM SUSPEND33PREVIOUSMENU12345678NETWNI Master #1WNI Master #2Central StationEthernet HubWirelessMonitorsynchronizedto Master #1WirelessMonitorsynchronizedto Master #1WirelessMonitorsynchronizedto Master #2WirelessMonitorsynchronizedto Master #2SpacelabsMonitoringNetwork   Part Number 062-0983-01 Rev C   page 3 - 3
b. 90309 Option "W" (Bedside or Slave)  The PC Ranger (90309-W) is a PC Scout bedside/transport monitor with added wireless communications capability.  The PC Ranger includes an extended rear panel containing the I/O Bay board (670-0623-xx), with an attached ethernet Interface board (670-0829-xx) in a slave configuration, a Proxim Radio card (010-0914-xx), and a dipole whip antenna. The Bedside (Slave) has two way communications with the 90310 Wireless Network Interface (WNI) "Master" (described in following paragraphs) using a 2.4 GHz to 2.485 GHz frequency-hopping radio link.  Waveforms, alarms, bed information, and configuration messages are transmitted from the slave to the network via the master. Network and configuration messages are sent from the master to the slave or from slave to master. WITH THE WIRELESS NETWORK SOFTWARE VERSION 2.03.06 OR HIGHER AND RADIO FIRMWARE VERSION 1.57 OR HIGHER, BED TO BED COMMUNICATION IS ALLOWED; WITH OPTIONAL INTERACTIVE NETWORK, FULL BED TO BED ACCESS TO BEDSIDE MONITOR MENUS IS POSSIBLE. THIS CAPABILITY ALSO INCLUDES ACCESS TO HARDWIRE MONITORS.  c. UCW – Z, 90367 and 90369 Option "Z" (Bedside or Slave)  The Ultraview 1030/1050 option Z (Wireless option) contains a built-in wireless unit similar to the external wireless unit on the PC Ranger Monitor. The basic difference between the Ranger and the Ultraview 1030/1050 is that the Ultraview 1030/1050 does not contain a 670-0829-XX ETHERNET INTERFACE  card.  The 90367/90369 imbeds the control functions of the 670-0829-XX card into the monitor’s main board, and the 010-0914-XX OEM radio card is connected directly to the main board.  Additionally the Ultraview 1030/1050 supports five outbound parameters and enhanced site survey functionality. The UCW option Z utilizes a 90310-C WNI which has been configured as a “slave”. This WNI communicates through the ethernet port of the UCW.  d. 90310 Option "A", "B", or “C” (Master, or Slave interface unit)   The Spacelabs Medical 90310 is unique to the wireless network. The 90310/Master/WNI (Wireless Network Interface) uses a modified 90485 module housing (see illustration at left) and a standard 90486 power supply combined with the 670-0829-XX PCBA (mounted internally from the rear of the module housing) and the 010-0914-XX OEM radio card. For purpose of this document, the "Master", "WNI", and the "90310" have the same meaning, except for the 90310-C, which is a Slave. The “Master” coordinates the communication with the “Slaves” on the same channel by controlling the frequency hopping pattern. Slave monitors synchronize with the master’s frequency hopping pattern, allowing continuous communication. The frequency-hopping pattern is dictated by the selected WNI “channel”. Therefore, the channel is not a specific frequency, but a pre-defined sequence of frequencies.  Part Number 062-0983-01 Rev C   page 3 - 4
The 90310-A is a Master WNI and contains one Network Interface and one Radio board; the 90310-B WNI has two Network Interface and Radio boards, and functions as two separate Masters in a single WNI housing. The 90310-C WNI is used as a slave interface for Spacelabs bedside monitors without internal wireless network capability. This allows wireless connection of Spacelabs network patient monitoring devices such as a UCW bedside monitor.  e. Technical Description Of Operation  The WNI uses a microprocessor located on the 670-0829-xx (PCB ASSY, ETHERNET INTERFACE, 90309) to handle all communication between the network interface circuitry and the OEM radio frequency card. Software controls the 12.5 MHz main CPU, the 25 MHz network CPU and the OEM RF card. All Spacelabs Medical software resides in a 2-megabyte PROM memory IC chip. The software for the OEM RF card resides in a 32-pin IC socket on the OEM RF card.  Master  The Master (always a 90310-A or B) functions as a network interface. It can be thought of as basically a wireless ethernet multiport. Each master only allows data traffic headed for wireless monitors that are in sync with that master to pass onto the wireless network.  Data traffic for monitors that are in sync with another master will be handled by that master. A master also passes data from its wireless network onto the hardwire network.  (See the table at the bottom of the page and drawing above for jumper locations.)  Slave  A Slave (a 90310-C, 90309-W Ranger, or wireless Ultraview 1030/1050) passes all of its ethernet data onto the wireless network. As mentioned earlier, it synchronizes with the frequency hopping pattern of one master, and that determines which master receives its data.  (See the table below and drawing above for jumper locations.)  Jumper Number Jumper Description Factory Default for “MASTER CONFIGURATION” (90310 A or B) Jumper Setting Factory Default for “SLAVE CONFIGURATION” (90309 W, or 90310-C)” Jumper Setting JP580  MSTR/SLAVE   MSTR (Master)  1-2  SLAVE  2-3 JP582  A (90310 A/B) B (90310 C) A (90310 A/B)  1-2  B (90310-C)  2-3 JP584 90309/90310  90310-A/B/C, Enables 10Base5 connector 2-3  90309, Disables 10Base5 connector 1-2 JP586 Diagnostic NRML/LOOP NRML, this is the normal software operating mode 1-2  NRML, this is the normal software operating mode 1-2  Part Number 062-0983-01 Rev C   page 3 - 5
f. Ethernet Interface Card  Note that the 670-0829-XX (PCB Assembly, Ethernet Interface) is used in the 90310 and the 90309-W.  The Ultraview 1030/1050 wireless monitor does not have the 670-0829-XX with the components discussed below.  The 670-0829-XX PCBA has a 16-position rotary microswitch (also referred to as a "thumb wheel switch") for channel selection. The switch is normally covered by a protective cap. Switch selections are made using a small screwdriver.  There are two operating modes for a Wireless bedside: fixed channel and auto channel select.  Fixed channel Mode   012BA9876543FEDC Any switch position from 1 though F (not zero) will assign a specific, fixed channel number to the 90310 or 90309-W. (On an Ultraview-1030/1050 the Radio configuration is set to a non-zero value). The channel selection on the slave monitor and the WNI must be the same for them to communicate. This limits the Wireless bedside to only one channel; even if a valid master is in the area on a different channel, the Wireless bedside will never synch to it. In the example illustrated here, channel C has been selected.  Auto-select Channel Mode  012BA9876543FEDC Setting the switch position to 0 allows a slave monitor to "roam". A WNI is never set to Auto-select. With this setting, the slave will change its channel to synchronize with any available Master, choosing the first one with an acceptable signal. Monitors that move frequently, or are used in transport situations, will be more likely to use auto channel select. Remember that only 20 waveforms from slaves may synch with any given master. Allowing more then 20 waveforms to attach to a single WNI can cause data dropouts and failure to attach to the WNI.  There are also 8 LED's on the edge of the 670-0829-XX PCBA that are viewable through a cutout just above the thumb wheel switch. During power-on diagnostics, these LED's display the test numbers as the self tests are performed. If a failure occurs, the LED’s will indicate which test failed. (Refer to the 90309/90309-W Service Manual, 070-0438-xx for diagnostic guidance). Note that the LED’s should only go through the self-test sequence at power up; if this sequence occurs during normal operation, it may indicate a hardware failure.  If the self tests complete successfully, all LED’s flash twice, the yellow (bottom) LED flashes to indicate that the system is operational, and the four highest LED’s indicate the current thumb wheel switch position in binary format. For example:  XXXX    Thumbwheel set to channel 1.  XXXX    Thumbwheel set to channel 2.  XXXX   Thumbwheel set to channel 3.  XXXX   Thumbwheel set to channel 4.     … and so on.  Part Number 062-0983-01 Rev C   page 3 - 6
g. OEM radio card  There are two types of OEM radio cards used in the Spacelabs wireless ethernet system, one for U.S. and one for European use. Both cards are identical in form, fit and function; only the filtering circuitry is different.  Part number 010-0914-xx  is for use in the US only. There are two versions of this card:  Proxim Radio card 010-0914-04 -- may use software version 1.57m or 1.8B Proxim Radio card 010-0914-05 -- requires the use of software version 1.8eB  The 010-0914-04 can be easily recognized because it has three metal RF shields on the card. There is a single, larger RF shield on the 010-0914-05 radio card (see picture below). The version of radio software is printed on the label on the software EPROM.   Older Proxim card (010-0914-04)  Newer Proxim card (010-0914-05)   •  Software level 1.8 is available for both radio cards 010-0914-04 and 010-0914-05, but the specific version is 1.8B for the -04 and 1.8eB for the -05.  The 010-0914-04 can have either 1.8B or 1.57m but cannot use 1.57 (with no m) or 1.8eB. The 010-0914-05 can only use 1.8eB. A radio card with the wrong version will work, but will have poor communications (visible as waveform gaps or dropouts) at distance or on loaded networks.  •  ALL Masters must contain version 1.8eB if ANY node is at software version 1.8x.   The other type of radio card, part number 010-0940-00, has enhanced circuitry to meet the more stringent European RF signal requirements and is called the "ETSI" OEM radio card. This card is NOT used with U.S. installations.  All three cards have a transmitting frequency range of 2.4 GHz to 2.4835 GHz with a transmitting power measured at the antenna of 100 milliwatts. The radio functions as a "frequency hopper" and by definition will "hop" between a preset range of frequencies and will spend less than 200 ms on each frequency before moving on to the next. The frequency hop sequence will vary depending on the thumb wheel channel selected, or the channel selected in the Network Setup, Radio Setup menu with the wireless 90367 / 90369 monitors. Part Number 062-0983-01 Rev C   page 3 - 7
h. Understanding Signal Interference  Physical Obstructions and Communication Range  Communication range between master and slave may be up to 500 feet nominal or 1000 feet for a clear line of sight transmission path across an open space. In a hospital environment this will likely be limited to 250 feet or less based on walls and other barriers.  How Solid Matter Affects Radio Transmission: All items found in hospitals will partially block or attenuate (reduce) RF radio waves by absorbing them, reflecting them, or refracting them (changing their direction). This can also lead to situations where signal strength is good but signal quality can be poor. Solid ObjectReflected SignalRefracted SignalIntended Signal PathAttenuated Signal     Cement, metal, plaster, wood, and even plants or people all block some fraction of an RF signal.  The denser the material, the greater the attenuation. For example, cement and metal will strongly attenuate an RF signal, while wood, plaster, or glass attenuate less. A signal will pass through windows (including safety windows with internal wire mesh) or non-metallic partition walls with only a slight loss of strength.  The signal will degrade but pass through solid walls of concrete. However a sheet of solid metal will effectively block transmission.   Signals from Master and Slave wireless monitors can travel only a very short distance through some items (depending on their thickness) and not at all through others. The greatest working distance between master and slave will occur when there is a clear line of sight between them. Anything placed between the master and slave will reduce the signal strength.  Communication range between master and slave will also vary depending on antenna positioning, the physical environment, and other factors. Part Number 062-0983-01 Rev C   page 3 - 8
  Solid ObjectReflected SignalRefracted SignalIntended Signal PathAttenuated SignalObjectObjectReflected SignalReflected Signal  Signal Strength And Signal Quality:  Signal strength and signal quality are not the same. Reflections can interfere with intended signals even though the strength of the signal will still measure as acceptable.  Familiar examples of this are "ghosts" on a television screen caused by reflections off buildings or hills; the TV antenna is picking up plenty of signal strength, but the signal quality is poor.  If you see good received signal strength, but the Link Quality value is poor, you may be seeing the affect of reflected signals. Changing the locations of wireless network components may clear up the problem.     RF Interference  Interference can affect the SMI wireless network in several ways. The most common is a loss of data, which results in waveform dropouts. Many devices can cause RF Interference by broadcasting or producing noise in the 2.4 GHz to 2.4835 GHz range. These devices include microwave ovens, airport radar systems, microwave communication systems, and other nearby electronic devices. The frequency hopping radio attempts to minimize this problem by jumping to another frequency every 200 milliseconds.  Part Number 062-0983-01 Rev C   page 3 - 9
i. Coverage Area  Domains  NOTE:  Information about Domains is only supplied for information and to better understand existing wireless networks which may already be installed in the hospital. Wireless networks sold to date (01/18/00) do not have capability to alter Domains in both the WNI and bedside monitors.  For communication on the wireless network to function, all nodes must be set to the same Domain. The default domain for Spacelabs Medical is 1 (one). Keep this in mind if installing wireless in a hospital that already uses Proxim wireless for other networks, as you may need to change the hospitals domain to a number other than one.  As of this date (01/18/00), only the Ultraview 1030/1050 wireless has the ability to change Domain. However, since the Domain number of the WNI cannot be altered, all Ultraview 1030/1050 wireless monitors must remain set to Domain 1.  Cells  A cell consists of a master and at least one slave synchronized to that master. In a physical sense, a cell may be defined as the boundary within which adequate communication from the master to the slave is assured. Cell boundaries are defined as test data throughput rates of greater than 40,000 Bytes per second. This throughput is measured during the pre-installation site survey (See Wireless Site Survey Procedure).  WNI’s set to the same channel may never be in the same cell (see following two figures), though the fringes of the two or more WNI’s cells may overlap. A WNI on a different channel, and its slaves, may be in the physical area defined as another WNI’s cell, and the two systems will not interfere.    Part Number 062-0983-01 Rev C   page 3 - 10
     Range  Range is the RF coverage distance between a master and a slave on the same channel. The absolute maximum range between a master and a slave is nominally 500 feet. This range is achieved only under ideal conditions. A more realistic maximum for very open areas in hospitals is 250 feet. Objects obstructing the line of sight between the master and slave reduce transmission distance.  Range vs. Cell  Even though a slave is within RF range of a master, it may not be seen within that cell. This is because the radios may see adequate RF signal strength, yet they may not be able to decode the network packets adequately to ensure communication.  Roaming  Roaming is the ability of a slave to change from one master to another and continue communications using the new master. Roaming occurs when the synchronized master stops transmitting or acknowledging transmissions. This includes both master failures and out of range conditions.  Roaming occurs as a slave moves in and out of various cells. In some installations, there may be more than one cell in an environment using the same channel (in the event you need to cover another area blocked by a solid RF impenetrable object you might use another master set for the same channel). A slave using the fixed channel mode may only communicate with masters on the same channel, so as the slave moves out of the cell of the first master, it loses synch, then acquires the signal of the second master.   Other installations may have overlapping cells of different masters. Wireless bedsides in the auto-channel select mode have the ability to move in and out of active cells of different masters. This would allow the Part Number 062-0983-01 Rev C   page 3 - 11
masters to communicate with the moving slave even though their channels don't match. The Wireless bedside would look for masters on another channel when it looses synchronization with its current master.  In either case, as the Wireless bedside approaches the boundary of the cell, and looses synch, a brief period of signal dropout is experienced at remote monitors until the Wireless bedside establishes synch with the new master. Generally speaking, the auto channel select mode allows quicker roaming since the cells of different channels may overlap more than WNI’s on the same channel.  j. Possible Monitor & WNI Configurations  There are different network configurations available for use with the Wireless network product. Selecting a configuration depends on several factors. These factors include the number of monitors to be used on the network, the coverage area needed, and the intended usage of the monitors - mobile or stationary.  Basic Network Types  Simple network (no roaming):   Less than ten monitors in a single area with no roaming desired. Suggested configuration:  Use Wireless bedsides in fixed channel mode.   Simple network with roaming:  Less than ten monitors with transport capability Suggested configuration:   Use Wireless bedsides in auto-channel select mode. Position WNI’s as needed to cover all areas in the transport corridor.  Large network (no roaming):   More than ten monitors in single area, no roaming Suggested configuration:   Use Wireless bedsides in fixed channel mode (maximum 10/WNI). Configure WNI Channels to balance load (i.e. 16 monitors = 8/WNI where cell boundaries permit). NOTE: This configuration is not suggested if the WNI’s can see each other.  Large Network with roaming:   More than ten monitors with transport capability. Suggested configuration:  It is preferable to use Auto Channel Select mode with the WNI’s carefully positioned to observe the 10 slave/WNI requirement by ensuring that cell boundaries cover bed locations and transport corridors.     Hospital-Wide networks:   Coverage of multiple units or floors, with or without transport capability Suggested configuration:  It is preferable to use Auto Channel Select mode with the WNI’s carefully positioned to observe the 10 slave/WNI requirement by ensuring that cell boundaries cover bed locations and transport corridors.   k. Communication Limitations of the Wireless Network  Network traffic   The network must be configured to assure that a single WNI will not be overloaded. Therefore, if using UCW or Ultraview 1030/1050 monitors you must assure that there are sufficient WNI’s to handle loads based on the number of waveforms being transmitted by the wireless monitors.  One WNI is limited to a maximum of 20 waveforms at a time. If this parameter is exceeded, unacceptable numbers of waveform dropouts will occur.  The first step in planning a wireless network installation is to know the number and type of wireless monitors that will be used in the intended coverage area.  Part Number 062-0983-01 Rev C   page 3 - 12
When looking at the equipment in a wireless network, you must remember these capabilities and limitations:  1. Each 90309-W PC Ranger can transmit either 1 or 2 waveforms at a time to a 90310 WNI.  2.  Each UCW wireless or Ultraview 1030/1050 wireless can transmit from 1 to 5 waveforms at a time to a 90310.  3.  A single 90310-A supports a maximum of 20 waveforms, and the 90310-B supports a maximum of 40 waveforms on two unique cells.  4. There are 15 unique radio channels. All 15 channels can co-exist in a cell at the same time.  Channel Assignment and WNI location: Upon powering up a Ranger, Ultraview 1030/1050 wireless, or wireless UCW monitor, it will search for and synch to the first WNI (master) it sees. The WNI generates a signal known as a “beacon" that tells the Ranger the master’s next frequency hop. Basically, the first WNI, with sufficient signal strength that the wireless monitor sees is the WNI that the wireless monitor will synch to. When it becomes necessary to use more than one WNI, the monitors and WNI’s need to have two or more channel numbers set so that some of the monitors communicate with one WNI, and the others communicate with the other. The WNI’s should be positioned to be sure that each monitor is communicating with the closest WNI.  NOTE: Keep in mind that the closest WNI will not necessarily be the one the wireless monitor attaches to. If signal strength and quality are acceptable from a more distant WNI, and it is the first one seen as the wireless monitor searches for a Master to synch with, then the wireless monitor will synch with the more distant WNI even though the closer WNI has more signal strength or better signal quality.  The number of monitors is based on the customer's order. Since this is not under your control, you need to calculate how many waveforms will potentially be active in the coverage area. You must also account for any monitors that are likely to roam through this cell (monitors on roll stands, etc.). Based on the numbers above, the maximum number of wireless monitors is calculated as follows:  EXAMPLE 1:  The proposed coverage area has 6 rooms with one 90309 wireless monitor in each room. Six monitors sending two waveforms each will result in a total of 12 waveforms. This is less than the limit of 20 waveforms maximum for a 90310-A, so this area will only require a single 90310-A.  EXAMPLE 2:  The proposed coverage area has 6 rooms with one Ultraview 1030/1050 wireless monitor in each room. Six monitors sending five waveforms each will result in a total of 30 waveforms. This exceeds the limit of 20 waveforms maximum for a 90310-A, so this area will require two 90310-A units or one 90310-B.  EXAMPLE 3:  The proposed coverage area has 10 rooms with one Ultraview 1030/1050 wireless monitor in each room. Ten monitors sending five waveforms each will result in a total of 40 waveforms. This exceeds the limit of 40 waveforms maximum for a 90310-B, so this area will require a 90310-B and an additional 90310-A, or three 90310-A units. Part Number 062-0983-01 Rev C   page 3 - 13
l. Selecting Wireless Network Equipment locations  WNI Master location  The placement of the 90310-A/B and its antenna is critical. Antenna placement and relative polarity (vertical orientation) are critical. Best placement of a Master for most universal coverage and greatest range will be in an unobstructed, centrally placed locations. This is, of course, an ideal location and may not be the most practical location to place the antenna. Mount the antenna such that it is vertically orientated (either upright or upside down) since any angle other than vertical will result in weaker RF transmission and receive strength relative to the slave(s). A pedestal mount style antenna is available with a six-foot cable. For best performance place this antenna near the ceiling. Therefore, since the cable length is six feet, the WNI (Wireless Network Interface) (Master) and antenna placement must be in close proximity. The central PCMS monitor is connected to the WNI via a standard SMI ethernet cable.  In open areas such as long hallways, it may be better to place some of the WNI’s in rooms off the hallway, allowing some intentional attenuation of the signal. This can actually improve performance where several rooms are located on a long corridor because roaming monitors will be forced to switch more often to a closer WNI. Remember that a wireless monitor does not switch to a new master just because its signal is stronger, so if all of the WNI’s are in the open hallway a monitor may stay synchronized to a distant WNI even though it may be right next to a WNI that would provide much better signal quality.  Sources of interference:  Watch out for sources of RF interference such as microwave ovens and do not place a WNI antenna closer than 20 feet from such sources. Remember to test all microwave ovens for emissions! Remember to check the floors above and below the wireless location also, as an interference source may easily penetrate a floor or ceiling.  WNI Channel Numbers - a setup tip:  When low signal strength forces a  wireless monitor to switch to another WNI, it tries to synchronize with the available WNI’s from its list of known Masters. It may improve performance slightly if the next number on the list happens to be the actual next WNI in the hallway.  If the WNI channel numbers are set so that, as a wireless monitor moves up the hallway, it encounters numerically sequential channel numbers, it will tend make better Master selections. For example, if the WNI channel numbers are set so that the monitor will encounter #2, then #3, then #4, etc. the monitor is more likely to synchronize with the closest WNI. If the WNI channel numbers are set so that you pass #2, then #9, then #6, etc, the monitor may synchronize with a more distant WNI (with less signal quality) simply because it is the first WNI found that has acceptable signal quality.  Bedside or Slave location  The placement of the slaves follows similar rules as the placement of a master. An open unobstructed area is best for universal coverage and greatest range. Remember that other RF transmissions or physical objects may interrupt the slave signals and waveform causing “drop outs”. Slaves can be in a fixed location or they may be mobile within range of the master.  Overlapping Restrictions  Central or Masters  One master’s signal must never directly overlap another master on the same channel. Electronic devices will not be damaged, but communications between some masters and slaves will be unpredictable resulting in increased waveform dropouts. If there are two or more masters on the same channel, they must be sufficient distance apart that the RF signal from one master will not directly overlap another. Masters on the same channel, correctly separated, may be networked together by using Multiport repeaters and standard SMI ethernet cables allowing areas blocked off by solid objects to be covered by another master on the same channel. Multiple masters that are within RF signal coverage of each other will not cause problems if masters are on separate, thumb wheel selected, channels.  Part Number 062-0983-01 Rev C   page 3 - 14
Bedsides or Slaves  Slaves may overlap the coverage (transmission) areas of other slaves. Slaves on the same channel or on different channels may overlap.   m. Installation Hardware  Antennae  IMPORTANT NOTE: The Ranger or Ultraview 1030/1050 wireless antenna and the WNI antenna are different:  •  The Ranger or Ultraview 1030/1050 wireless use the 117-0029-00 Ranger 2.4 GHz Dipole Antenna (stubby antenna), which has a gain of x2.  Do NOT use this antenna with a 90310 Wireless Network Interface (WNI)!  Do NOT use the WNI antenna (650-0521-00) with a wireless monitor (90309 or 90367 / 90369)!  •  The 90310-A/-B/-C WNI uses the 650-0521-00 Base-Mounted WNI Omni-directional Antenna  (with 6' cable), which has a gain of x1.  Do NOT use this antenna with 90309 or 90367 / 90369 Wireless monitors.  Do NOT use the 117-0029-00 antenna with a 90310!  DO NOT try to use an Ultraview 1030/1050 wireless as a Master to do a site survey!  Obviously, if you set an Ultraview 1030/1050 wireless to be a Master to use in place of the 90310 WNI, you will get TWICE the received signal level that a real WNI would produce because of the higher antenna gain. If this is done for a site survey, this will result in designing a layout that will be too cold to work with a real WNI Master.   WNI / 90486 / antenna wall mounting  The WNI uses the same wall mounts as the 90485 remote module housing.   Power Source  The power for the WNI (Wireless Network Interface) Master unit comes from a 90486 power supply. Each WNI (90310-A, -B, or -C) should have its own dedicated 90496 external power supply.   Cables  There is no direct connection between a WNI and a central station monitor; they communicate using ethernet. The cables for communication from the ethernet repeaters use the same 15 pin AUI cables as existing SMI network cables. The 90310 housing utilizes the same DC power cables as the 90485 Module Housing.  Part Number 062-0983-01 Rev C   page 3 - 15
      Bed Rail, Bedside, Rolling Stand & Wall mounting  All portable bedside monitors are supported by the existing bedside mounts and roll stands. Wall mounting a 90310 is performed using the UCW wall channels. Part numbers for mounting hardware are included in the parts list which follows. Part Number 062-0983-01 Rev C   page 3 - 16
n. Part Numbers  Description Part NumberWNI Antenna Kit, includes Pedestal Mount Antenna and Antenna Mount  650-0521-00 Antenna, Dipole, 2.4 GHz, 90309 ("stubby" antenna for Ranger and wireless UV1050)  117-0029-00 Wall Mount, track, 24”  016-0350-00 Wall Mount, track, 38”  016-0355-00 Wall Mount, Arm  016-0375-00 Accessory Kit, Flush Mount, 90310  016-0425-00 Cable, brick to WNI, 2'  012-0391-02 Cable, brick to WNI, 4'  012-0391-04 Cable, brick to WNI, 8'  012-0391-08 Cable, brick to WNI, 10'  012-0391-10 Cable, WNI to WNI housing, 1'  012-0392-00 Cable, Brick to WNI  012-0387-00 90309-W Ranger Parts Ranger Antenna, 2.4 GHz Dipole (stubby antenna)  117-0029-00 Cover, I/O Bay,Wireless,90309  200-0201-00   Proxim Radio Card -- Requires The Use Of Software Version 1.57M  010-0914-04 Proxim Radio Card -- Requires The Use Of Software Version 1.8EB  010-0914-05 PCB Assy, Ethernet Interface, 90309  670-0829-00   IC, Flash, 28F010 - EPROM installed as U610 on the I/O Bay PCB Assy  170-0087-00 PCB Assy, I/O Bay,Ethernet,90309  670-0623-08   Bracket, Ethernet / Flex, I/O Bay, 90309  407-0324-00  Cable Assy, Ethernet, I/O Bay, 90309  175-0910-00   Cable Assy, Flexport, I/O Bay, 90309  175-0909-00   Cable, I/O Bay,Wireless,90309  175-0944-00   Label, I/O Bay W/L Connector, 90309  334-1429-00   Meter, Microwave Leakage Detector - for Ranger site surveys, see PSN  149-0002-00 90310-A, B, C Omnidirectional Antenna, WNI   650-0521-00 Cable, Antenna, 90310  175-0922-01 Proxim Radio card -- requires the use of software version 1.57M  010-0914-04 Proxim Radio card -- requires the use of software version 1.8EB  010-0914-05 PCBA, Connector Board, 90310  670-0841-00   PCB Assy, Ethernet Interface, 90309  670-0829-00 Enclosure, Left, Module Housing, 90310  437-0093-02   Enclosure, Right, Module Housing, 90310  437-0093-01   Cover, Top, 90310  200-0208-00   Enclosure, Card Cage, 90310  437-0112-00   Part Number 062-0983-01 Rev C   page 3 - 17
Cover, Left, 90310  200-0205-00   Cover, Right, 90310  200-0204-00   Cover, Rear Panel, DC, 90310  200-0209-00   Cover, Bottom, 90310  200-0206-00   Cover, Front Panel, 90310  200-0207-00   Label, Front Panel, 90310  334-1440-00   Cable Assy, PCB To Power Supply,  90310  175-0939-00   Cable Assy, Ribbon, AUI, 90310  175-0938-00 Power Supply   90486 Meter, Microwave Leakage Detector  149-0002-00 90367 / 90369 Wireless Ethernet Option Parts Proxim Radio card -- requires the use of software version 1.57M  010-0914-04 Proxim Radio card -- requires the use of software version 1.8EB  010-0914-05 Cable, Antenna, 90363/90369 (cable from stubby antenna to radio card)  175-0922-01   Cable, Flex Circuit, 90363/90369 (ribbon cable from radio card to Main Board)  175-1002-01   Ranger Antenna, 2.4 GHz Dipole (stubby antenna)  117-0029-00 Part Number 062-0983-01 Rev C   page 3 - 18
2.  Wireless Network Site Survey Procedure  (NOTE:  Refer to Appendix 1 for information regarding operation of the site survey laptop computer with the RangeLAN2 PCMCIA card that is used during this procedure.)  a. Things To Have Before Beginning The Site Survey  •  Current, accurate floor plans for the proposed coverage area from the hospital Facility Manager.  •  Meter, Microwave Leakage Detector, Spacelabs part number 149-0002-00. (Refer to Appendix 2, Microwave Leakage Measurements, for information on using this device).  •  Model 90310 Wireless Network Interface (WNI).  •  Laptop computer with Proxim RangeLAN2 program and PCMCIA card.   b. Things To Know About The Site Before Beginning The Survey:  •  Review the floor plans obtained from the hospital Facility Manager. Look for any potential architectural problems, such as thick load-bearing walls, x-ray areas, fire walls, elevator shafts, heavy doors, or doors with leaded glass or walls with wire mesh, or any other features that may make radio transmission difficult. These areas will need special attention in the survey to ensure adequate coverage.  •  Are there any other wireless products operating in the 2.4 - 2.485 GHz band?  If so, ask who manufactures it, and if known, who makes the radio portion of that product? The presence of other frequency hopping radios in the area does not preclude a SMI wireless installation, but before proceeding, consult with the hospital Biomedical Engineering and MIS departments to identify which products are in use, and specifically, the maker of the radio portion of that product. Submit a complete list of other wireless equipment including model, manufacturer and other information along with complete site survey. Flag this survey for review by Monitoring Technical Support.   c. Actions Before Site Survey:  1. Obtain current, accurate floor plans for the proposed coverage area(s) from the hospital Facility Manager. Make several "working" copies for use in planning the installation.  2. Walk through the area with hospital staff to identify the desired coverage area for the wireless network. IMPORTANT: Clearly mark the boundaries of the proposed coverage area on the floor plan, and have a qualified representative of the customer site sign the resulting coverage diagram to confirm their approval of the coverage area. Explain that any changes after the survey may affect the amount of equipment required and render the survey (and Sales quotation) invalid. A copy of the signed floor plans must be submitted with the TIP book for approval.  3. Perform an RF sweep of the area to identify any possible interfering frequencies. Mark locations of known potential interference sources such as microwave ovens on the floor plan. (Remember that interference can be generated from a floor above or below the installation floor). If microwave ovens are in the area, perform an emission test using the “Microwave leakage detector tool”, part number 149-0002-XX (see Appendix 2, "Microwave Leakage Measurements"). To minimize interference caused by microwaves, do not place a WNI within 20 ft. of these areas.   Part Number 062-0983-01 Rev C   page 3 - 19
d. Performing a Wireless Site Survey:   Use the up-to-date floor plans for the coverage area with the coverage area desired by the hospital staff.  1.  Find a boundary for the coverage area.  2.  Place the WNI at the boundary of the coverage area. Mount the test antenna to the ceiling, which is how it will be positioned in actual use - do NOT place it on a desk or table.  3.  Place the survey laptop in the location that the typical bedside antenna would be.  4.  Assure vertical antenna orientation for best signal strength.  5.  Start the RL2SETUP site survey mode and establish a Directed Link to the WNI.  6.  Walk the laptop away from the WNI to the point where the data throughput averages 40 KB/Sec.  7.  Move the WNI to the location just identified, and plot the rest of the area, staying within the 40 KB/sec boundary.  8.  Repeat the process if necessary to provide full coverage of the desired area.  9.   Document the site survey and complete the other pre-installation documentation.   When making measurements, be sure to close room and hallway doors in the area you are surveying. Solid core or metal doors can severely attenuate an RF signal!   NOTE:  If your proposed installation has WNI’s that are on the same channel, it is necessary that the WNI locations be out of range of each other. Refer to drawings in previous sections of this document for additional details.   A Sample Survey.  Refer to the floor plan illustrated on the next page as an example. Using the steps previously outlined, place the WNI in the room at the end of a hall (step 1). Take laptop computer to a point (step 2) down the corridor where the data throughput of 40 KB/Sec is seen from the room. Move the WNI to that location and map the rest of the area (step 3), using the minimum data rate of 40000 Bytes/Sec minimum AND a minimum Link Quality of 3 to define the limits of the coverage area of the WNI.  Repeat the process at all three ends of the unit.    Part Number 062-0983-01 Rev C   page 3 - 20
 Site Survey Example 2:  Completed drawing.  (or use tab and space keys,)Microwave oven positionThroughput @60kB/sec move WNI hereWalk down hallwayPlace WNI hereWalk down hallway recordingsignal strengths3. When throughput falls to 40kB/sec,move WNI here2. Walk down hallway recording signalstrength as you go.1. Place WNI here. Note all rooms and corridors to be covered by this survey. Note microwave placement and allow at least 20 feet between any potential microwave location and a WNI antenna. When a microwave is present check it for interference as described in Appendix 2. If the microwave is causing interference have the Biomed Department remove it, shield it, or attempt to clean the seals and retest. Dirty seals are the largest cause of unsafe radiation from microwave ovens. Part Number 062-0983-01 Rev C   page 3 - 21
 Final documentation:  Document the findings of the survey on the floor plan. Provide one copy with the TIP book for future review should this be necessary.   e. Completing the site survey:  Site Survey Example 1:  Concerns and Logical Placement The following site survey illustrates concerns and logical placement. This would be the first step in designating test areas. The drawing should also show the location, or potential location, of any microwave ovens. Also noted must be any other wireless devices in the 2.4 GHz band.  Emergency Room shown below has ordered a quantity of ten 90309's equipped with option W (wireless).    The coverage area defined by the hospital staff is any of the following areas:  •  Emergency rooms •  Trauma rooms •  One observation area •  X-ray room does not require coverage •  All hallways in the emergency ward  The floor plan must show desired coverage of each room to be monitored. Also listed must be hallways, type or walls, windows, doors and the general attributes of the area where the wireless is to be installed.  Part Number 062-0983-01 Rev C   page 3 - 22
Based on the complex physical shape and the site survey of the coverage area, it is determined that we need two masters. The survey shows that X1 master can cover; TR1, TR2, TR3, TR4, TR10, TR11, TR12, ER5, ER4, ER3, the lower hallway, the middle hallway, the right half of the upper hallway, the PCMS central area and the observation area. Thus we need X2 to cover TR5, TR8, ER8, ER7, ER6, the left side hallway, and the left half of the upper hallway. We may notice X2 will also cover ER5, the right half of the upper hallway, the left end of the lower hallway, TR4 and possibly TR12.  IMPORTANT:  As mentioned earlier, one WNI is limited to a maximum of 20 waveforms at a time. If this parameter is exceeded, unacceptable numbers of waveform dropouts will occur. The two WNI’s in this example may not be adequate if the number of wireless monitors is increased, even though they provide full area coverage.   Installation options for this example:  •  Use a different channel for each master and Auto-channel select mode for the slaves. This allows more flexibility to reposition masters to optimize coverage without concern that the masters would interfere with each other. This illustrates the ability of a monitor to roam from one channel master to another.  •  Use a single fixed channel for both masters and all slaves. If both X1 and X2 are on the same channel, and as long as masters on the same channel cannot directly receive other master signals, the setup will be valid. [Don’t forget the floors above and below in channel selection. Masters on these floors may have overlap on this floor.]  If the x-ray room needs coverage, a separate master, on a third channel, would need to be installed in the “X-RAY” room, and the slaves must use auto-channel select mode.  If the installation described above included twenty monitors, the installation options would be as follows:  •  If the monitors are not mobile, and x-ray is not covered, it would be possible to use two WNI’s on two different channels (also keeping in mind the limit of 20 parameters per WNI. If the monitors are going to be set for more than 2 outbound parameters, more than 2 WNI’s may be needed). The slaves need to be positioned so that they are equally divided between the two WNI’s according to the cell boundary of each WNI. Half of the Wireless bedsides must be set to one channel, and half on another channel.  •  If the monitors are mobile, and must function from any room in the unit, then a pair of WNI’s must be installed where the X1 and X2 master locations are indicated. The slaves must use auto-channel select mode.   Part Number 062-0983-01 Rev C   page 3 - 23
3. Post-Installation Verification and Troubleshooting  a. Acceptance Criteria:  Because of the nature of microwave communications, and the effects on it from some of the transient events listed earlier, it is normal to observe infrequent gaps in remote views of Wireless waveforms.   The maximum number of waveform gaps allowed is three per minute, lasting less than 3 seconds each, on a 16-waveform central where the Wireless bedsides are stationary.  During transport, it is expected that the number of dropouts will increase as the wireless monitor nears the edge of the WNI coverage area and switches to a new WNI.  ALL monitor locations must meet or exceed the following minimums as measured with the RangeLAN2 card:  •  The LINK QUALITY is displayed on the main site survey screen as a number from 0 (out of range) to 5 (best) must be 3 or above.  •  The RECEIVED SIGNAL STRENGTH (RSSI), displayed as a bar graph from 0-100% must be at least 40%.  •  In the Directed Link display ensure that the minimum DATA THROUGHPUT from the laptop to the WNI, is at least 40 Kbytes/second.   b. Troubleshooting with the RangeLAN2.  Once the wireless network is installed, you may use the RangeLAN2 utility to test the installation and verify system performance.  With the WNI’s in their installed locations, verify each bedside location has minimum throughput of 40 KB/second and a Link Quality of at least 3. Verify throughput and quality for any WNI that can be seen from any given room.  Wireless bedside software version 2.03.06 and beyond will display the radio card’s network address as the Wireless bedside software signs on after power-up. Knowing this information is useful in trouble-shooting Wireless bedsides with radio problems. If the received signal strength (RSSI) of a Ranger, 1030/1050 wireless, or wireless UCW is significantly lower than RSSI for other bedsides, or data throughput is low compared to other radios on the air, you can suspect a problem with the radio PCBA, the antenna or antenna cable, or the monitor’s internal antenna cable.  One feature of the RangeLAN2 program is the master list (see illustration below). The master list will show all masters in a given area. To search for Spacelabs WNI’s, search Network Domain One. To search for other Proxim Masters, (non-Spacelabs equipment), search all Network Domains.  Part Number 062-0983-01 Rev C   page 3 - 24
  The master list will provide you with the WNI radio’s network address. Use the network address to differentiate WNI’s in cases where multiple WNI’s are set to the same channel.   When the Main Menu is opened, the window displays which master (WNI) the laptop is synchronized to (see illustration below). The Site Survey window lists all stations (wireless bedsides) synchronized to that specific WNI. Since you can determine the radio address of the monitor at power up. You know the WNI address from the master list; thus, you can determine which WNI a given wireless monitor is communicating with. This is especially useful when you have an installation with multiple WNI’s on the same channel, or the wireless bedsides are set to use the Auto-Channel Select mode, and there are coverage problems. Channels dropping off the central display or numerous gaps in the waveform display at the central are evidence of coverage problems.   Part Number 062-0983-01 Rev C   page 3 - 25
    For example, the floor plan on page 9 illustrates one room where two WNI’s are clearly seen. Let’s say that any wireless monitor placed in that room frequently has gaps in the waveform at the central station.  You can use the RangeLAN2 program to determine which WNI the wireless monitor in the problem room is communicating with. You may find that the wireless monitor is subject to more dropouts when it is synchronized with WNI A than WNI B. To determine this, use Site Survey tool as previously described, to determine the actual throughput of the bedside to WNI A and WNI B.  Upon power up of a wireless monitor (or laptop), it will search for and synch to the first WNI (master) it sees generating a signal known as a “beacon”. The beacon tells the wireless monitor the master’s next frequency hop. There are other factors involved, but simply stated, the first valid WNI the wireless monitor sees is the one that it will synch to. You can observe this by placing the laptop between two WNI’s. Repeatedly open, and then exit the site survey mode. By observing the percentage of times the laptop synchs to one WNI over another, you can approximate how a wireless monitor would act, if booted in the same location. If you want to link to a WNI you can carry the laptop to that location and wait for it to switch. Or you can disable Roaming and force the laptop to connect to a specific WNI.  Going back to our example, in the suspect room you find a tendency to synch to WNI A about 30% of the time, and WNI B 70 %. Open a Directed Link to WNI A and WNI B and observe the throughput data. In this example, the data throughput from the suspect location to WNI A is actually 10-15 kB/sec, and the data throughput to WNI B is closer to 40-50 kB/sec.   The reason that data throughput falls is that the radio portion of the network guarantees delivery. If the radio need to re-send packets, the throughput naturally falls. This can occur for many reasons: interference from microwaves or other sources; radio malfunctions; metal carts rolling down a corridor; fire doors closing; a large crowd of people gathered in a corridor. 10 Kb/sec throughput means that data is still getting through, but some packets may be lost because at the monitor level, waveform packets are sent as multicast messages. This means that there is no destination address associated with the waveform; therefore, the sender (wireless monitor) does not know that packets are missed and will not re-transmit. The result is gaps or holes in the waveform.  Part Number 062-0983-01 Rev C   page 3 - 26
Again, back to our example. If the lowered throughput from WNI A is not attributable to transient causes as listed above, WNI A may need to be relocated to an area where is will be out of range of the suspect room. This will assure that a wireless monitor in the suspect room will synch to WNI B, where the communications are better.  Remember that the effect of any change of WNI position must be evaluated from all rooms that can see the WNI, not just the suspect room.  Part Number 062-0983-01 Rev C   page 3 - 27
c. Troubleshooting with the ULTRAVIEW 1030 / ULTRAVIEW 1050 Site Survey screen.   NOTE: Current ULTRAVIEW-1030/ULTRAVIEW-1050 site survey screen does not provide throughput information. Therefore this tool is only to be used for network troubleshooting and operational verifications.   To enter the SITE SURVEY mode:  Go to “MONITOR CONFIGURATION” Screen. Select “PRIVILEGED ACCESS” button. Enter Password. Select “MORE” button. Select “SERVICE FUNCTIONS” button. Select “SYSTEM INFORMATION” button. Select “SITE SURVEY” button.  ULTRAVIEW-1030/ULTRAVIEW-1050 site survey mode display provides important information for verification of site operation.  Note:  In the ULTRAVIEW-1030/ULTRAVIEW-1050 Site survey, signal range is 80 to 230. A reading below 100 should be considered as Marginal operation. A reading below 90 will experience dropouts and should be cause for re-evaluation of WNI locations and coverage areas.   ULTRAVIEW-1030/ULTRAVIEW-1050 Site Survey Display  •  The Channel number shown at the top of the screen is the current sync, or “Master”, channel number.   •  In site survey the statistics screen is a running total of all nodes seen since the last system reset.   •  Before each entry in the table there is either a “*” or “-“ indication. The “*” indicates node sent a configuration message in the last 20 seconds. The “–“indicates configuration message not seen within the last 20 seconds.  •  Assure you are using an available node number for the survey monitor. If the node number of this bed is in the survey table then the node number is a duplicate. Since the table only shows received configuration packets it must never show a node with the same number as the survey tool node.  Part Number 062-0983-01 Rev C   page 3 - 28
APPENDIX 1 - RangeLAN2 PCMCIA Card  a. Installing and Configuring the RangeLAN2 PCMCIA card.  The RangeLAN2 card will come with driver disk(s) that are used to install the RangeLAN2 software onto a laptop computer. REFER TO THE MANUFACTURER’S SOFTWARE INSTALLATION INSTRUCTIONS FOR SPECIFIC STEP-BY-STEP SOFTWARE INSTALLATION INFORMATION. A typical installation is shown here to provide essential configuration information needed to make the RangeLAN2 work with Spacelabs wireless networks.  Installing PCMCIA card: The RangeLAN2 card must be installed in the lower PCMCIA socket of the laptop.   Installing software onto laptop:  1.  Install the RangeLAN2 card in the lower PCMCIA socket of the laptop. Start the laptop and wait until Windows 95/98 auto-detects the RangeLAN2 card. The window will say “Select which driver you want to install for your new hardware:”  Choose “Driver from disk provided by hardware manufacturer”. Put the driver disk into the A:/ drive and click on “OK”.  2.  The installation screen will appear. Follow the on-screen instructions.  3.  Complete the installation by following the manufacturer’s instructions.  5.  Using Windows Explorer, find the directory containing the file named Pnetcon.exe (see example below) and right-drag  the Pnetcon.exe icon onto the Desktop to create a shortcut.    6.  Double-click on the Pnetcon.exe icon to start the RangeLAN2 program. The Main Menu will appear:  Part Number 062-0983-01 Rev C   page 3 - 29
   7.  Select Configuration.  8.  Click on the arrow beside the station type pull-down menu. Set the station type as a Station (see below). There may be times that the laptop will need to be set up as a Master or Alternate Master; however, for most site survey mode applications, Station is the desired setting.    Part Number 062-0983-01 Rev C   page 3 - 30
9. In the Configuration screen set the Network Domain to 1 (see below).       10.  Click OK.  11.  The software is now installed and configured.  Part Number 062-0983-01 Rev C   page 3 - 31
b. Using the Proxim RangeLAN2 PCMCIA card for Site Survey.  Equipment required: Laptop computer with RangeLAN2 PCMCIA card installed and RL2SETUP program loaded. Spacelabs Medical 90310 WNI with 90486 power supply   Starting the RangeLAN2 program: Double-click on the Pnetcon.exe icon on the Desktop.  The program Main Window is as follows:      Performing an RF Sweep:  •  Start the RangeLAN2 program.  •  Select SNOOP.  The display below will appear: Part Number 062-0983-01 Rev C   page 3 - 32
  The SNOOP MODE display shows the RF spectrum that the wireless monitor radio uses. If the site survey is for a new SMI wireless monitor installation, there should not be any activity in this spectrum. If there is, other wireless products or noise sources are in the area. The activity characteristic of a spread spectrum, frequency-hopping radio is several peaks per screen update. Once the activity in the RF spectrum is identified, power the WNI on. You should now see the typical display as above.  A display as shown in the following example indicates the presence of interference in the wireless radio frequency band. This interference may be due to microwave ovens, or other wireless products. Note any difficulties encountered on the survey forms. These difficulties should be noted even if the interference seems to go away during the survey. Flag these problems and refer them to Spacelabs Technical Support along with the completed survey forms. If interference is severe, contact Technical Support to obtain a 2.4 GHz Spectrum analyzer for completion of the survey.    Part Number 062-0983-01 Rev C   page 3 - 33
Entering SITE SURVEY mode:  Start the RangeLAN2 program. Select SITE SURVEY.  The Site Survey mode display provides three important pieces of information for testing a wireless installation: Link Quality, Received Signal Strength,  and data throughput via a Directed Link.       The Site Survey mode displays the Node Address of the radio. This Node Address (MAC address) is for the wireless card and is not associated with the monitor’s Node ID number. This window also identifies the WNI Master Name as SPACELABSM?. A flashing asterisk flashes indicates activity.  The LINK QUALITY is displayed on the main site survey screen as a number from 0 (out of range) to 5 (best). In the site survey mode, the higher the link quality, the better.  The RECEIVED SIGNAL STRENGTH (RSSI) is displayed as a bar graph from 0-100%. The RSSI is a less desirable method of surveying, since it is possible that the radios may see an adequate RF signal, yet the quality of the data may be lower than desired.  Note: Both Link Quality and RSSI are good first line tests. However for best determination of signal quality, continue with the following tests using Directed Link.   The Site Survey screen also has a selection for Roaming Enabled. This feature allows the laptop to “roam”,  (switch masters as needed). In the site survey process, the roam enabled should not be selected, since you want to stay synchronized to the WNI, and not switch to another master. To change from roaming to non-roaming, use a mouse to de-select “roaming enabled” (see below).  Part Number 062-0983-01 Rev C   page 3 - 34
   DIRECTED LINK. To enable the Directed Link display, on the Site Survey main screen place the mouse pointer over a displayed master and click. A Directed Link allows measurement of the data throughput from the laptop to the WNI.  The desired minimum data throughput from the laptop to the WNI, in a Directed Link, is 40 Kbytes/second. Signal strength should not go below 40%.     Part Number 062-0983-01 Rev C   page 3 - 35
APPENDIX 2 - Microwave Leakage Measurements  a. Microwave ovens can be a major source of interference in the 2.450 GHz range and may cause loss of data between the bedside and central stations or remote views. This loss of data will be seen as “holes” in waveform data, or if the interference is of a long duration, complete loss of a channel at the central station. In the event microwave ovens are located in the wireless coverage area anywhere within about 300 feet of either the WNI or wireless bedside, then these microwave ovens must be tested for possible interference. If in doubt about interference “potential” setup a network using central station, WNI and one bedside. Place a glass of water into the center of the microwave (NEVER TURN ON A MICROWAVE OVEN WITHOUT A “LOAD” PLACED INSIDE OF IT) and turn it on at it’s highest power setting. Watch the central station and verify that NO data dropouts occur while the oven is turned on ( a test duration of 30 seconds to a minute is adequate, be sure to change water if a longer test is desired as water should not be boiling for this test).  b. A simple measuring device has been released for use in determining oven leakage (Spacelabs part number 149-0002-00, "Meter, Microwave Leakage Detector"), and assist you in finding offending oven noise sources. Both EPA and FCC have limits concerning emission levels for these ovens and published the following as guidelines (excerpt):  •   Power density of microwave ovens shall not exceed one milliwatt per square centimeter at any point 5 centimeters (2 inches) or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter, 5 milliwatts per square centimeter at any point 5 centimeters (2 inches) or more from the external surface of the oven.  •   Leakage testing – Microwave should be operating at it’s maximum output and containing a load of 275 ±15 milliliters of tap water placed within the cavity of the center of the load carrying surface provided by the manufacturer.   c. Refer to the operator's instructions for the microwave oven emission meter that you are using.  d. Emission measurement - With the oven set for maximum power output, operational, and water placed into it, test for leakage as indicated in the figure above. Readings above 5 mW/cm2 are unacceptable and the oven should be removed from service. To co-exist with Spacelabs wireless networks, emission levels should be no greater then 1.5 mW/cm2 (Federal safety standards allow higher leakage levels for safety purposes, but an emission level exceeding 1.5 mW/cm2 may cause wireless network problems). If emissions are greater, the hospital responsible party must service the unit. Cleaning the door and mating surfaces in some cases may resolve the issue.  e. MD-2000 MICROWAVE DETECTOR OPERATING INSTRUCTIONS  A Microwave Detector (part number 149-0002-00) is available for use by Customer Service Representatives to determine the emissions level of microwave ovens in areas where wireless products are in use.  Proper use of the microwave detector enables the CSR to find sources of wireless communications interference and prevent signal drop-offs.  To use the MD-2000:  1.  Place a cup of water inside the microwave oven.  2.  Press and hold the orange button on the microwave detector MD-2000.  The unit’s display will show a count-up sequence, the warning light will briefly turn on, and a beeping tone will be generated for 1 second.  When the tone stops, the display will show a 0.00 reading.  This numeric value is measured in mW/cm2.  Part Number 062-0983-01 Rev C   page 3 - 36
3.  While pressing the orange button on the MD-2000 unit, start the operation of the microwave oven (highest power output setting).  The microwave oven must be operational for a minimum of 30 seconds.  4.  Place the MD-2000 unit within 2 inches around the door cracks of the microwave oven.  The meter MUST be held in a horizontal orientation perpendicular to the surface you are measuring, such that you can read the display from the top.  Do NOT turn the device vertically as this will severely affect the unit’s accuracy  (see drawing below for proper orientation).          Microwave oven and MD-2000 in side view. Note the orientation of the MD-2000 and the oven door. During the test the oven is plugged in and running.   5.  Note the MD-2000 readings on the display.  Typical readings of properly insulated ovens will show a value of less than 1.00 mW/cm2.  Readings of 5.0 mW/cm2 or greater will be accompanied by a beeping alarm tone and the flashing of the red warning lamp.  Microwave ovens that emit 5.0 mW/cm2 or greater of energy violate the FDA and EPA recommended safety levels and must be replaced or repaired immediately.  6.  Readings close to but less than 5.0 mW/cm2 may affect wireless communications and should be located as far as possible from any wireless devices.  As mentioned earlier, Spacelabs Medical recommends that ovens in proximity of wireless networks emit less than 1.5 mW/cm2.  Part Number 062-0983-01 Rev C   page 3 - 37