Smart Technologies and Investment GTOF3100 GTO ACCESS WIRELESS ESTATE INTERCOM User Manual

Smart Technologies & Investment Ltd GTO ACCESS WIRELESS ESTATE INTERCOM

Contents

user manual

rev - 12/01/10Moving GateAreaDriveway10'10'10'10'NEVER INSTALLany control devicewithin gray areaNEVER install the keypad portion of this system where a person can reach through the gate to activate it, or where a person can touch the gate while activating the keypad. The recommended minimum distance between the gate and keypad is 10 ft.©2010 Gates That Open, LLCPrinted in China for GTO  Wireless Estate Intercom Installation ManualKit Includes:A. KeypadB.  Keypad CoverC.  Jumper (required for hard-wired installation)D.  Keypad Battery CoverE.  Base UnitF.  Base Unit Rechargeable BatteryG. TransformerH.  Screws for mounting Keypad CoverHow it Works:A visitor without an entry code presses the CALL button on the keypad. The base (indoor) unit and the keypad will ring. A user at the base (indoor) unit answers the call by pressing the PUSH TO ANSWER/TALK button. The user at the base unit then presses the GRANT PERMISSION button to allow the visitor to operate the gate. The keypad’s GRANTED light comes on, indicating that the visitor can now push any number key on the keypad to open the gate.Visitors with access codes simply use their code to operate the gate. Temporary codes can be programmed to expire within a set number of days. WIRELESSACEFGHDBPROFESSIONAL RESIDENTIALACCESSSYSTEMSWARNINGGTO–Gates That Open, LLC • 3121 Hartseld Road • Tallahassee, Florida 32303Telephone (850) 575-0176 • Fax (850) 575-8912 • www.gtoinc.com • www.gtoaccess.comF3100MBC
rev - 12/01/10FCC WARNING: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installations. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  • Reorient or replace the receiver antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.Estate Intercom/Keypad FeaturesKeypad •Thekeypadilluminatesandbeepsatthepressofanykey.Atnight,thekeypadwillilluminatewhentheproximitysensorsdetectmotionnearthekeypadface. •Whenavalidcodeisentered,theSTATUSlightwillblinkrapidly,thekeypadwillbeepthreetimes,andtheGRANTEDlightturnsgreen. •Thekeypadremainsactivefor40secondsafterenteringavalidcode:pressinganykeyonthekeypadwhilethegateisinmotionwillstopthegate;pressinganykeywhilethegateisstoppedwillcausethegatetoreversedirection.After40seconds,thekeypadwillbeep3threetimesandgointo“idle”mode,andtheGRANTEDlightwillturnoff. •Ifmorethan20keypressesareenteredwithoutmatchinganEntryCode,theSTATUSlightwillashrapidly,anerrortonewillsoundfor1second,andthekeypadwillgointo“lock-down”modefor40seconds. •Ifmorethan10secondselapsebetweenkeypresses,thekeypadwillbeep3threetimesandgointo“idle”mode.Master and Entry Codes •Upto100EntryCodesmaybeprogrammedintothekeypad. •TemporaryEntryCodescanbeprogrammedtoexpirewithinonetoseven(1–7)days. •EntryCodesremainstoredinmemoryevenwhenthekeypadbatteriesgodead. •AllEntryCodesaredeletedbypressingtheRESETbuttononthekeypad;MasterCodedefaultsto“1234.”Base Unit •Thebaseunitispoweredbyarechargeablebattery(included);thechargeismaintainedbythetransformer. •Thebaseunitcanbedisconnectedfromthetransformerallowingittobemovedanywherewithinrange. •Uptothreeadditionalbaseunitscanbeaddedtothesystem. NOTE: The keypad, not the base station, initiates the call and operates the gate. The base station is for answering calls and granting “permission” for the gate to be opened.INTERCOM/KEYPAD SPECIFICATIONSFrequency 318 MHz from keypad to gate opener900 MHz from keypad to base stationMemory – Keypad Stores up to 100 four-digit entry codesPower Consumption – Keypad 60 mA when relay is closedPower Supply – Keypad Four C batteries (plus 8-24 Vdc for hard-wired installations)Power Supply – Base Unit 9 Vdc 300 mA transformer; 3.6V Ni-MH 800 mA rechargeable battery packRange from Keypad to Base Unit 500’ wirelessRange from Reypad to Gate Opener 50’ wireless 100’ wired using 16 AWG wireRelay Output – Keypad Momentary, normally open dry contact closes for 2 seconds upon activationRelay Output Rating – Keypad 12 or 24 Vdc 100 mAWiring – Keypad Power & Relay Output 16 AWG stranded low voltage direct burial wire
1rev - 12/01/10Keypad and Base Unit OverviewFront InteriorCalling Light:Turns RED when calling; turns GREEN when call is answered.Granted Light:Turns GREEN when access permission is granted.Program Button:Used to program Entry Codes.Status Light:Blinks once when any key is pressed; provides visual feedback when programming keypad.3DEF9WXY6MNO20CALL4GHI7PRS1ABC8TUV5JKLPresenceSensors123456789ETD+0-ID SET RESETREQUIRES 4 “C”SIZE BATTERIES123456789ETD+0-ID SET RESETREQUIRES 4 “C”SIZE BATTERIESRelay Output:Used to connect the keypad to gate opener control board (hard-wired installations).Power Input:To connect keypad to gate opener power source (hard-wired installations).DIP Switches:Match keypad DIP switch settings to Entry Transmitter’s DIP switch settings.Jumper:OFF: Wireless mode 318 MHz enable. ON: Relay out (hard-wired installations). 318 MHz disable.Reset Button:Press this button for 2 seconds to program keypad to Master Code default “1234” (and delete all other codes).ID Set Button:Used to sync additional base units with keypad.Battery Holder and Cover:Use 4 “C” batteries. FacePOWER Keypad Batt Low Grant PermissionPush To Answer/TalkEnd CallDV  9V Power Light:GREEN: charging; RED: battery power mode (unplugged from transformer); Blinking RED: low battery.Push To Answer/Talk Button:To answer call from keypad: press and hold to talk; release to listen.Grant Permission Button:Must be pressed before the person at the keypad can press any key to open the gate.End Call Button:Terminates the call.Keypad Battery Indicator Light:ON when keypad battery is low.Power Jack:Connect transformer to charge the battery.ID SETVOLUMEPOWEROFF ONVolume Control:Controls volume level of speaker.Battery Access Cover:Rechargeable 3.6 Volt Ni-MH battery (included).ID Set Button:Used to sync additional base units with keypad.ON/OFF Switch:Turn OFF to conserve battery power.Bottom1. Install Keypad and Base Unit BatteriesStep 1:  Unlock the bottom of the keypad and separate it from its cover. Remove battery cover and install four “C” batteries (required, not included). Replace the battery cover.Step 2:  Remove the base unit battery cover using a small phillips head screwdriver. Install the rechargeable Ni-MH battery (included). Replace battery cover.ID SET
2rev - 12/01/102. Connect the Transformer and Test Base UnitStep 1: Find a convenient location near an AC outlet to mount or place the base unit. Step 2: Plug the transformer into the outlet and connect it to the base unit.The base unit can be disconnected from the transformer for use in another location. The battery will last approximately four (4) hours when unplugged from the transformer. You can turn the base unit OFF to conserve battery power, however it will not receive a signal.Step 3: Test the base unit by pressing the CALL button on the keypad. The base unit will ring. Charge battery for 12 hours before using the system for the first time.POWERKeypadBatt LowGrant PermissionPush To Answer/TalkEnd CallDV  9VTransformer110 Vac outlet3. Install and Test KeypadFor wireless applications, the keypad must be in line of sight of and no more than 50 ft. away from the gate opener receiver. Test the keypad range before permanently mounting it. Step 1: At the gate, set the keypad DIP switches to match your Entry Transmitter’s DIP switch settings. NOTE: If you have not adjusted your gate opener’s Entry Transmitter from the factory setting, see the “Personalize Transmitter Settings” section in your gate opener’s installation manual.Step 2: Test the keypad using the default Master Code “1234.” It will activate the gate.Step 3: Test the keypad range by pressing the CALL button. You will hear the base unit ringing through the keypad speaker.Step 4: Mount the keypad cover using the screws provided.  NOTE: a metal housing or metal object can affect range.Step 5: Slide the keypad into the cover and lock it.You will need to hard-wire your keypad to the gate opener if you:  • Do NOT have a GTO Entry Transmitter.  • Have a GTO Access Systems GP Series gate opener.  • Live in an area with high radio frequency interference.Skip to page 5 for instructions.123456789ETD+0-ID SET RESETIf you use this button to operate gate, put the 9th DIP Switch  in the “0” positionDual Button Entry Transmitter1 2 3 4 5 6 7 8 9 ECE A23S 12V ALKALINE BATTERY + 0 – LED Single Button Entry TransmitterIf you use this button to operate gate, put the 9th DIP Switch in the “+” positionChange the Keypad’s DIP Switch Settings NOT the Entry Transmitter Dip Switch Settings
3rev - 12/01/10Program New Master Code1. Press and Release Program Button:2. Enter current Master Code:      (example: the factory default Master Code)3. Press and Release Program Button:4. Enter the Function Code:5. Press and Release Program Button:6. Enter the new Master Code:7. Press and Release Program Button:8. Enter the new Master Code again:9. Press and Release Program Button:Program Button Status Light= Your 4-digit code.4. Program the Keypad  •  A Master Code is needed to add, remove, or program Entry Codes. • Factory default Master Code is “1234.”   • Keypad can only enter “program” mode from “idle” mode.  • Keypad will beep three times before going into “idle” mode (more than 10 seconds between key presses).   Add New Entry Code1.  2.   Master Code3.  4.  Function Code5. 6.   New Entry Code7. Delete Entry Code1.  2.   Master Code3.  4.  Function Code5. 6.   Code to be deleted7. Delete All Entry Codes1.  2.   Master Code3.  4.  Function Code5. Add Temporary Entry Code*In step 4, you will need to enter a number from 1 through 7 to indicate the number of days until the Entry Code expires.1.  2.   Master Code3.  4.  Function Code & # of days Code will be active*5. 6.   Temporary Entry Code7. Programming Confirmed:  Keypad will beep 3 times.Error Message: Status light will flash rapidly, error tone will sound for1 second and keypad will return to “idle” mode (changes not saved). • Entry Code is not 4 digits.  • New Master Codes don’t match (“Program New Master Code”). • Memory is full (already 100 codes).          • No matching code is found (“Delete Entry Code”).
4rev - 12/01/105. Sync Additional Base Units (optional)If you purchased additional base units (F3101MBC), you must sync each additional unit with the keypad so they can communicate. Step 1:  Install the battery and turn the base unit ON.Step 2:  Press and release the “ID SET” button on the keypad.Step 3:  Press the number on the keypad that corresponds to the base unit you are adding. You will hear a number of beeps corresponding to the number you pressed. For example, if you are adding a second base unit to the system, press “2,” the keypad will beep TWO times. If you are adding a third base unit, press “3,” the keypad will beep THREE times, etc.Step 4:  Press the “ID SET” button on the base unit for approximately two seconds then release. You will hear THREE beeps from the base unit and THREE beeps from the keypad, which means the base unit and keypad are synced.IMPORTANT: Base units need to be placed at least 10 feet apart to prevent interference.6. Test the IntercomIMPORTANT: The base unit and the keypad cannot be within 15 feet of each other when operating. If units are closer than 15 feet, the signal will be inconsistent and emit feedback. Have someone press the CALL button on the keypad. When the base unit inside the house rings, press the ANSWER button and talk to the person at the gate to check the connection and range. Then press the GRANT PERMISSION button and have the person press any key on the keypad to activate the gate.Using the Wireless Estate IntercomNOTE: The keypad, not the base station, initiates the call and operates the gate. The base station is for answering calls and granting “permission” for the gate to be opened.Using the Intercom  •  Press the CALL button on the keypad to ring the base unit inside the house.  •  The base unit will ring when it receives a CALL from the keypad:  hold the ANSWER button to talk to the visitor, release the ANSWER button to listen. Press the GRANT PERMISSION button to allow the visitor to open the gate (by pressing any number key on the keypad). The END CALL button terminates the call.  •  After the keypad’s GRANTED light turns green, press any number key to open the gate.Using Entry Codes  •  When a valid code is entered, the STATUS light will blink rapidly, and the keypad will beep 3 times.  •  The keypad remains active for 40 seconds after entering a valid code: pressing any key on the keypad while the gate is in motion will stop the gate; pressing any key while the gate is stopped will cause the gate to reverse direction. After 40 seconds, the keypad will beep 3 three times and go into “idle” mode.    •  If more than 20 key presses are entered without matching any Entry Codes, the STATUS light will ash rapidly, the error tone will sound for 1 second, and the keypad will go into “lock-down” mode for 40 seconds.  •  If more than 10 seconds elapse between key presses, the keypad will beep 3 three times and go into “idle” mode.Intercom ID CodesThis keypad and base unit are synced at the factory to communicate with each other. This base unit is considered to be “unit #1” when adding more base units to the system.ID SET buttonID SETVOLUMEPOWEROFF ONKeypad - InsideBase Unit – BottomKeypad - FrontID SET button3DEF9WXY6MNO20CALL4GHI7PRS1ABC8TUV5JKL123456789ETD+0-ID SET RESET
5rev - 12/01/10123456789ETD+0-ID SET RESETHard-wirefromGate OpenerPower Supplyfrom OpenerBattery#1#2POWERRELAYJumper ONwireless modeJumper OFFwired modeHARD-WIRED INSTALLATION You will need two pairs of 16 gauge (AWG) stranded, direct burial, low voltage wire (RB509), one pair to hard-wire the communication between the keypad and the gate opener, the other to exend the life of the four “C” batteries. NOTE: The four “C” batteries are required for reliable operation of the keypad.Step 1: Turn the gate opener’s power switch OFF.Step 2: Determine how the wires will enter the keypad (e.g., from the back through a hole drilled in the post; running the wire on the post surface). Drill a hole in the back of the keypad cover and pull the wire into the cover. Then mount the cover to the post using the screws provided. Run wire through PVC pipe from the ground to keypad and from the ground to the opener control board to protect it from lawn mowers or grazing animals.Step 3: Wire the keypad to the gate opener control board. Strip 3/16” off the ends of one pair of low voltage wires. Attach the wires to the terminal block marked RELAY on the keypad control board as shown. Then connect wire #1 to the CYCLE terminal on the gate opener control board, and wire #2 to the COM terminal on the gate opener control boardNOTE: If you have a PRO 1000/2000/SL1000/SL2000 gate opener, connect wire #1 to the WHT accessory terminal, and wire #2 to the GRN accessory terminal.Refer to your gate opener instruction manual for more details on wiring the gate opener control board. Step 4: Wire the keypad to the battery. Strip 3/16” off the ends of the second pair of low voltage wires. Attach the wires to the terminal block marked POWER on the keypad control board as shown. Connect the other end of the wires to the opener’s battery:  one end to the POSITIVE (RED) terminal and the other to the NEGATIVE (BLACK) terminal.Step 5: Connect the jumper between the two terminals on the keypad control board (ON) as shown. Step 6: Slide the keypad into the cover and lock.Step 7: Replace the gate opener control board cover and turn the power switch ON. Step 8: Program the keypad (page 3).Drill Hole
6rev - 12/01/10TroubleshootingPressing the keypad CALL button does not ring the base unit:  1.  Check the batteries in the keypad and replace them if necessary.   2.  Make sure the base unit is turned on and the volume is turned up.  3.  Try moving the keypad and the base unit closer to each other (no closer than 15 ft.).  4.  Perform “Sync” procedure below (this will require two people):  a.  Open the keypad and locate the “ID SET” button above the batteries. Locate the “ID SET” button on the bottom of the base unit.  b.  Make sure the “antenna-to-antenna” distance between the keypad and the base unit is at least 15 feet.  c.  Press the “ID SET” button on the keypad until you hear a beep, then release.  d.  Press the “ID SET” button on the base unit for approximately 2 seconds then release. You will hear ONE beep from the base unit and TWO from the keypad, which means the keypad and base unit are synched.  e.  Test the system by pressing the CALL button on the keypad to see if the base unit receives the signal. Once the system is working, you will need to sync additional base stations (see page 4).The Master Entry Code does not open the gate and the GRANTED light does not turn green.  1.  Check the batteries in the keypad and replace them if necessary.   2.  Program the keypad (page 3). The Master Entry Code does not open the gate and the GRANTED light turns green.WIRELESS Installation:   1.  Verify that your Entry Transmitter operates the gate.  2.  Verify that the Keypad DIP switches are matched to the Entry Transmitter DIP Switches (page 2).   3.  Make sure the JUMPER in the keypad is NOT installed (page 5).WIRED Installation:  1.  Be sure the wires are securely connected to the gate opener control board (page 5).  2.  Make sure the JUMPER in the keypad is installed (page 5).You’ve forgotten the Master Entry Code:The following will remove all Entry Codes from the keypad and program the Master Code back to factory default.  1.  Press and hold the RESET button in the keypad for two seconds. Master Entry Code is now “1234.”  2.  Program the keypad (page 3).Limited One Year WarrantyGates That Open, LLC (“GTO”). gate opener accessories are warranted by the manufacturer against defects in workmanship for a period of one (1) year from the date of purchase, provided recommended installation procedures have been followed.In the case of product failure due to defective material or manufacturer workmanship within the one (1) year warranty period, the accessory will be repaired or replaced (at the manufacturer’s option) at no charge to the customer, if returned freight prepaid to GTO - Gates That Open, LLC • 3121 Hartseld Rd. • Tallahassee, FL 32303. IMPORTANT: Call 850/575-4144 or fax 850/575-8950 for a Return Goods Authorization (RGA) number before returning goods to factory. Products received at the factory without an RGA will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of the one (1) year warranty period or six (6) months, whichever is greater. GTO will pay the shipping charges (equal to United Parcel Service GROUND rate) for return to the owner of items repaired under warranty. The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper installation or use, connection to an improper power source, tampering, or if damage was caused by lightning, electrical power surge, wind, re, ood, insects, or other natural agent.After the one (1) year warranty period, GTO or one of its authorized service centers will make any necessary repairs for a nominal fee. Call GTO at 850/575-4144 for more information. This warranty gives you specic legal rights, and you may also have other rights which may vary from state to state. This warranty is in lieu of all other warranties, expressed or implied. NOTE: Verication of the warranty period requires copies of receipts or other proof of purchase. Please retain those records.If you have any questions or concerns, please contact our Technical Service Department Monday thru Friday 8:00 a.m. to 7:00 p.m. (ET) at 1-800-543-1236 or 850-575-4144GTO–Gates That Open, LLC • 3121 Hartseld Road • Tallahassee, Florida 32303Telephone (850) 575-0176 • Fax (850) 575-8912 • www.gtoinc.comThe contents of all material available on this installation manual are copyrighted by Gates That Open, LLC (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law. GTO®, GTO/PRO®, Mighty Mule® are registered trademarks of GTO - Gates That Open, LLC. GTO Access Systems™ is a trademark of GTO - Gates That Open, LLC. These marks are the exclusive property of GTO - Gates That Open, LLC (“GTO”).  All rights are reserved by GTO, and these marks may not be used, in any form, without the prior, written permission of GTO.

Navigation menu