Signify North America SNS200 Ceiling Luminaire mounted light sensor User Manual 20180801 v1 PLt 15142QG EasySense QIG RevD 061818

Philips Lighting North America Corporation Ceiling Luminaire mounted light sensor 20180801 v1 PLt 15142QG EasySense QIG RevD 061818

User Manual_20180801_v1 - PLt-15142QG_EasySense QIG_RevD_061818

SensorsEasySenseFixture-Mount Philips EasySense Quick Installation GuideCommercial Product Name Order CodeEasySense Fixture-Mount Sensor SNS102  SNS200  SNS201SNS300Connection  ColorWhite NeutralBlack LineGreen GroundPurple SR+Brown SR-Compatible LED DriversSensor Part NumberDriver Model Number DescriptionXI040C110V054VPT1 Xitanium 40W 0.1-1.1A 27-54V 120-277V SRXI075C200V054VPT1 Xitanium 75W 0.1-2.0A 27-54V 120-277V SRSpecications available at www.philips.com/XitaniumSR.  Note: Below data applicable only for SNS200. Refer to Certied partner documentation for information applicable to SNS300.Wiring DiagramXITANIUM SR LED DRIVEREASYSENSE LED+LED+LED-LED-RSET2SGNDNFC ANTENNASR-Connectors SR+SRSRLINENEUTRALGROUND NCConnectors(non-polarized) Use 18AWG solid copper wire, rated >=600V/90C.  Strip wire to 3/8”.Electrical InformationInput Voltage Powered by SR driver low-voltage interfaceCurrent Consumption  13mANominal Power Consumption 200mWStandby Power < 1 W on luminaire level, including driver standby powerOccupancy SensingType Passive infrared (PIR)Enable/Disable Default enabledDetection O/Auto-on; Red LED indicates “on”Eco On Level   0-100%Hold Time 0.5-60 minutesViewing Angle X=72°, Y = 86° ( See detection pattern)Background Light Level 0-100%Prolong Time 0 minutes - innityGrace Fading 0-25 secResponse Time/Fading to Switch On/O  0.7SecDaylight SensingEnable/Disable Default enabledAuto-calibration Upon power-upViewing Angle 40° (half value sensitivity); 2% cut-o point at 75°Task TuningFull Light Setting 0-100%Environment & ApprobationOperating Ambient Temperature Range 0°C to 55°COperating Humidity 0–95% non condensingStorage Temperature -25°C to 85°CStorage Humidity 0-95% non condensingMax Case Temperature (Tcase) 55°CAgency Approbations UL, CSA; FCC; Tested and approved for use in plenumsCertication California Title 20Limited Warranty 5 yearsDigital Interface Xitanium SROtherStatus Indicators Red, Yellow. Yellow LED on: Vacancy & Sensor is functional;  Red LED on: Motion is detectedNo. Drivers per Sensor Four (max)Field Conguration via NFC or IR. Parameters set via Philips eld apps© 2018 Philips Lighting Holding B.V. All rights reserved.  Philips reserves the right to make changes in specications  and/or to discontinue any product at any time without notice  or obligation and will not be liable for any consequences  resulting from the use of this publication.philips.com/easysensePhilips Lighting North America Corporation10275 W. Higgins Road, Rosemont IL 60018Tel: 800-322-2086  Fax: 888-423-1882Customer/Technical Service: 800-372-3331OEM Support: 866-915-5886Philips Lighting Canada Ltd.281 Hillmount Rd, Markham, ON, Canada L6C 2S3Tel. 800-668-9008PLt-15142QG_EasySense QIG_RevD_061818  06/18  page 1 of 2Document #: 4435 631 00371 REV. DOperation and Conguration via Mobile App EasySense operates immediately upon installation and energization without further commissioning. If changes from  default settings are desired, EasySense can be congured via Philips eld apps through NFC or IR. For a complete  description of the features and default settings—as well as details on the app—refer to www.philips.com/easysense. FCC and IC Statement This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC) license-exempt RSS  standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modications not expressly approved by Philips could void the user’s authority to operate this equipment.  This product is intended for commercial use only.This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.Déclaration De Conformité À La Fcc/Ic Ce dispositif est conforme à la partie 15 des règles de la Federal Communications Commission (FCC) des États-Unis et d’Industrie Canada (IC) exempts de licence RSS norme(s). Son fonctionnement est assujetti aux deux conditions suivantes : (1) Ce dispositif ne doit pas provoquer de brouillage préjudiciable, et (2) il doit accepter tout brouillage reçu, y compris le brouillage pouvant entraîner un mauvais fonctionnement. Tous les changements ou modications non expressément approuvés par Philips, sont susceptibles d’annuler le droit de l’utilisateur à se servir de cet équipement. Ce produit est exclusivement destiné à un usage commercial.Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.Connection  ColorRed LED+Blue LED-Orange RSET2Green SGND
1.72 [43.8] MAX 0.96 [24.3] MAX0.66 [16.8] MAX1.97 [50.0] MAX0.30 [7.5] MAX0.75 [19.0] MAX1.73 [44.0]0.67 [17.0]R0.09 [2.3]1.71 [43.5] 1.71 [43.5]0.63 [16.0]0.63 [16.0]Sensor Dimensions (in/mm)Mounting Dimensions (in/mm)Mounting in U-shaped slot in sheet metal (max thickness 1 mm)Mounting in cut-out in sheet metal (thickness 0.7 mm to 1.0 mm)Fixture with EasySense installed Mounting in a slot     Mounting in a cut-out with mounting ring     Note: Consult factory for accessory mounting ring to secure sensor to cut-out.  Accessory Mounting Ring•  Part Number SMR-50 / Set of 50.•  Ordered separately, not included.Accessory Mounting Bracket•  Part Number SMB-50 / Set of 50.•  - Ordered separately, not included.

Navigation menu