Siemens WTPIWLAN-V200 SIMATIC WTP 277F IWLAN User Manual Wireless Teach Pendant F IWLAN V2

Siemens AG SIMATIC WTP 277F IWLAN Wireless Teach Pendant F IWLAN V2

Contents

Users Manual p1

Wireless Teach Pendant F IWLAN V2  ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ SIMATIC HMIHMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions   08/2010 A5E02453837-01 Preface  Overview  1 Safety instructions and standards  2 Planning the use  3 Mounting and connection  4 Operator controls and displays  5 Configuring the HMI device  6 Safety-related configuration  7 Commissioning a project  8 Commissioning the plant  9 Fail-safe operation  10 Operating a project  11 Service and maintenance  12 Technical specifications  13 Appendix  A Abbreviations  BPRELIMINARY II 1.7.2010
  Legal information     Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER  indicates that death or severe personal injury will result if proper precautions are not taken.  WARNING  indicates that death or severe personal injury may result if proper precautions are not taken.  CAUTION  with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.  CAUTION  without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.  NOTICE  indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING  Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.    Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY  A5E02453837-01  Ⓟ 06/2010 Copyright © Siemens AG 2010. Technical data subject to changePRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  3 Preface Purpose of the operating instructions  These operating instructions provide information for manuals derived from the requirements for mechanical engineering documentation according to DIN EN 62079. This information relates to the place of use, transport, storage, mounting, use and maintenance. These operating instructions are intended for: ●  Users ●  Commissioning engineers ●  Maintenance personnel Pay particular attention to the section "Safety instructions and standards (Page 35)". You can find more information such as operating instructions, examples and reference information in the online help of WinCC flexible. Required knowledge  General knowledge of automation technology and process communication is needed to understand the operating instructions. It is also assumed that those using the manual have experience in using personal computers and an understanding of Microsoft operating systems.  Scope of this manual  The manual applies to the "Wireless Teach Pendant F IWLAN V2" HMI device in combination with the following software: ●  STEP 7 V5.4, as of SP2 ●  Add-on package "S7 Distributed Safety", V5.4, as of SP3 ●  WinCC flexible 2008, SP2  NOTICE   Manual belongs to HMI device The supplied manual belongs to the HMI device and is also required to repeat commissioning. Keep all supplied and supplementary documentation for the entire service life of the HMI device. Provide all stored documents to subsequent owners of the HMI device.  PRELIMINARY II 1.7.2010
Preface      Wireless Teach Pendant F IWLAN V2 4 Operating Instructions, 08/2010, A5E02453837-01 Trademarks  The following names marked with the ® symbol are registered trademarks of Siemens AG: ●  HMI® ●  SIMATIC® ●  WinCC® Style conventions  This manual uses the following style conventions.  Style Convention  Scope "Add screen"   Terminology that appears in the user interface, for example dialog names, tabs, buttons, menu commands  Required input, for example, limits, tag values.  Path information "File > Edit"  Operational sequences, for example, shortcut menu commands <F1>, <Alt+P>  Keyboard operation Please observe notes labeled as follows:    Note A note contains important information about the product described in the manual and its use, or a specific section of the manual to which you should pay particular attention.  Naming conventions  This manual uses the following naming conventions.  Term  Applies to Plant   System  Machining center  One or more machines Actuate   By means of the touch screen on the HMI device  By operating a mouse on the HMI device Range name   Describes an effective range which is recognized by an HMI device Figures  This manual contains illustrations of the described devices. The illustrations can deviate from the described device as originally supplied. PRELIMINARY II 1.7.2010
 Preface   Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  5 Technical Support Technical support for the products covered in the manual is available in the Internet at: ●  Technical Support  (http://support.automation.siemens.com) ●  Support Request  (http://support.automation.siemens.com/WW/view/en/16605654) ●  Service  (http://support.automation.siemens.com/WW/view/en/16604318) ●  Contacts and office locations  (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●  Training center  (http://sitrain.automation.siemens.com/sitrain/default.aspx?AppLang=en) Additional information on SIMATIC products is available in the Internet at: ●  Industry Portal  (http://www.automation.siemens.com/_en/portal/index.htm) ●  Overall SIMATIC documentation  (http://www.automation.siemens.com/simatic/portal/html_76/techdoku.htm) Recycling and disposal  The products described in this manual are recyclable because of the low level of contaminants in its components. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. Used batteries and rechargeable batteries  Used batteries and lithium ion batteries are hazardous waste. Always dispose of used batteries and lithium ion batteries in accordance with the regulations in effect. Identify the container provided for this purpose with the label, "Used batteries and rechargeables".   Note Batteries and rechargeables do not belong in the garbage. The user is legally obliged to return used batteries and rechargeable batteries. You can deposit used batteries and rechargeables at any public collection site and anywhere batteries or rechargeables of similar type are sold.  You can also send batteries and rechargeables to the following address: Siemens AG Industry Sector Returns Center Siemensstr. 2 90766 Fürth Germany  PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  7 Table of contents    Preface ...................................................................................................................................................... 3 1  Overview.................................................................................................................................................. 13 1.1  Product overview .........................................................................................................................13 1.2  Scope of delivery .........................................................................................................................13 1.3  Wireless Teach Pendant F IWLAN ..............................................................................................14 1.4  Main rechargeable battery ...........................................................................................................16 1.5  Accessories..................................................................................................................................16 1.6  Equipment for HMI device and plant............................................................................................17 1.6.1  Overview ......................................................................................................................................17 1.6.2  Docking station.............................................................................................................................17 1.6.3  Charger°.......................................................................................................................................18 1.6.4  Power supply unit.........................................................................................................................19 1.6.5  RFID tag.......................................................................................................................................20 1.6.6  Access point.................................................................................................................................21 1.7  Communication and approved controllers ...................................................................................22 1.8  Software requirements.................................................................................................................22 1.9  Supported WinCC flexible objects ...............................................................................................23 1.10  Configuration and process control phases ..................................................................................26 1.11  Areas in the RFID tag system......................................................................................................27 1.12  Rapid roaming..............................................................................................................................29 1.13  Terms for fail-safe operation ........................................................................................................32 2  Safety instructions and standards............................................................................................................ 35 2.1  Safety instructions........................................................................................................................35 2.2  Approvals .....................................................................................................................................36 2.3  Standards on operating safety.....................................................................................................38 2.4  Operating conditions ....................................................................................................................39 2.5  Risk analysis of the plant .............................................................................................................40 2.6  Safety functions of the EMERGENCY STOP button ...................................................................41 2.7  Safety functions of the enabling mechanism ...............................................................................42 2.8  Electromagnetic compatibility ......................................................................................................44 2.9  Transport and storage conditions ................................................................................................46 3  Planning the use...................................................................................................................................... 47 3.1  Checklist.......................................................................................................................................47 3.2  Operating conditions ....................................................................................................................48 PRELIMINARY II 1.7.2010
Table of contents      Wireless Teach Pendant F IWLAN V2 8 Operating Instructions, 08/2010, A5E02453837-01 3.3  Insulation resistance, protection class and degree of protection................................................ 50 3.4  WLAN properties......................................................................................................................... 51 3.5  Planning protection zones in the RFID tag system..................................................................... 52 3.6  Planning an installation location for RFID tags ........................................................................... 54 3.7  Planning the installation location and clearance of the docking station...................................... 56 3.8  Planning the installation location of signal lamps ....................................................................... 57 3.9  Coexistence of the frequency bands........................................................................................... 58 3.10  Planning information security...................................................................................................... 59 4  Mounting and connection......................................................................................................................... 63 4.1  Check the scope of delivery........................................................................................................ 63 4.2  Installing an RFID tag.................................................................................................................. 63 4.3  Installing the docking station....................................................................................................... 64 4.4  Connecting the docking station and charger............................................................................... 65 4.5  Connecting the HMI device......................................................................................................... 66 4.5.1  Safety instructions....................................................................................................................... 66 4.5.2  Opening and closing the terminal compartment ......................................................................... 67 4.5.3  Ports and reset button................................................................................................................. 68 4.5.4  Inserting a memory card ............................................................................................................. 69 4.5.5  Connecting the rechargeable buffer battery................................................................................ 71 4.5.6  Replacing and charging the main rechargeable battery ............................................................. 72 4.5.6.1  Safety instructions....................................................................................................................... 72 4.5.6.2  Replacing the main rechargeable battery ................................................................................... 73 4.5.6.3  Charging the main rechargeable battery..................................................................................... 75 4.5.6.4  Showing the battery charge ........................................................................................................ 76 4.5.7  Connecting the PLC.................................................................................................................... 77 4.5.8  Connecting the configuration PC ................................................................................................ 78 4.5.9  Connecting a USB device ........................................................................................................... 80 4.6  Switching on and testing the HMI device....................................................................................81 4.7  Switching off the HMI device....................................................................................................... 82 5  Operator controls and displays ................................................................................................................ 83 5.1  Overview ..................................................................................................................................... 83 5.2  LED display ................................................................................................................................. 85 5.3  Power management.................................................................................................................... 87 5.4  Safety-related operator controls.................................................................................................. 88 5.4.1  EMERGENCY STOP button ....................................................................................................... 88 5.4.2  Enabling button ........................................................................................................................... 90 5.4.3  Testing the function..................................................................................................................... 92 5.5  Operator controls ........................................................................................................................ 93 5.5.1  Operating the rotary switch ......................................................................................................... 93 5.5.2  Operating the illuminated push-button........................................................................................ 93 5.5.3  Evaluating operator controls ....................................................................................................... 93 5.5.3.1  Overview ..................................................................................................................................... 93 5.5.3.2  Evaluating operator controls as direct keys ................................................................................ 94 5.6  Holding, operating and setting down the HMI device ................................................................. 95 PRELIMINARY II 1.7.2010
  Table of contents   Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  9 6  Configuring the HMI device...................................................................................................................... 97 6.1  Desktop and Loader.....................................................................................................................97 6.2  Operator input options ...............................................................................................................100 6.3  Enabling and disabling SecureMode .........................................................................................101 6.4  Control Panel .............................................................................................................................102 6.4.1  Overview ....................................................................................................................................102 6.4.2  Functions in the Control Panel...................................................................................................102 6.4.3  Operating the Control Panel ......................................................................................................104 6.4.4  Using the screen keyboard in the Control Panel .......................................................................104 6.4.5  Changing settings for operation.................................................................................................107 6.4.5.1  Configuring the screen keyboard...............................................................................................107 6.4.5.2  Changing display brightness......................................................................................................108 6.4.5.3  Setting the character repeat rate of the screen keyboard .........................................................109 6.4.5.4  Setting the double-click..............................................................................................................110 6.4.5.5  Calibrating the touch screen ......................................................................................................111 6.4.5.6  Starting the HMI device again....................................................................................................113 6.5  Entering and deleting a password..............................................................................................114 6.6  Configuring the WLAN connection.............................................................................................116 6.7  Changing and displaying general settings.................................................................................125 6.7.1  Setting the date and time...........................................................................................................125 6.7.2  Regional and language settings.................................................................................................127 6.7.3  Setting the screen saver ............................................................................................................127 6.7.4  Setting the location of the project...............................................................................................130 6.7.5  Setting the delay time for the project .........................................................................................131 6.7.6  Enabling sound and setting sound volume................................................................................132 6.7.7  Backing up registry information and temporary data .................................................................133 6.7.8  Displaying general system properties........................................................................................134 6.7.9  Displaying memory distribution..................................................................................................134 6.7.10  Displaying information about the HMI device ............................................................................135 6.7.11  Activate memory management ..................................................................................................136 6.7.12  Display firmware ........................................................................................................................137 6.7.13  Displaying licensing information.................................................................................................137 6.7.14  Displaying the charge status of the batteries.............................................................................138 6.8  Enabling PROFINET IO.............................................................................................................138 6.9  Setting the PROFIsafe address .................................................................................................140 6.10  Reassigning an RFID tag ID ......................................................................................................141 6.11  Programming the data channel..................................................................................................142 6.12  Configuring network operation...................................................................................................143 6.12.1  Overview ....................................................................................................................................143 6.12.2  Specifying the computer name of the HMI device .....................................................................145 6.12.3  Specifying the IP address and name server..............................................................................146 6.12.4  Specifying the logon data...........................................................................................................148 6.12.5  Configuring e-mail......................................................................................................................148 6.13  Changing Internet settings.........................................................................................................151 6.13.1  Changing general settings .........................................................................................................151 6.13.2  Setting the proxy server .............................................................................................................152 6.13.3  Changing Internet security settings ...........................................................................................153 6.13.4  Importing, displaying and deleting certificates...........................................................................154 PRELIMINARY II 1.7.2010
Table of contents      Wireless Teach Pendant F IWLAN V2 10 Operating Instructions, 08/2010, A5E02453837-01 6.14  Saving to external storage medium – backup........................................................................... 156 6.15  Restoring from external storage medium – Restore ................................................................. 157 7  Safety-related configuration................................................................................................................... 161 7.1  General procedure .................................................................................................................... 161 7.2  Checklist for configuration......................................................................................................... 162 7.3  SIMATIC STEP 7 ...................................................................................................................... 163 7.3.1  Configuring in STEP 7............................................................................................................... 163 7.3.2  Assigning parameters for communication between the HMI device and the controller............ 163 7.3.3  "SIMATIC S7 Distributed Safety" add-on.................................................................................. 166 7.3.4  Checklist for EMERGENCY STOP configuration...................................................................... 167 7.3.5  Using F-FBs .............................................................................................................................. 168 7.3.6  F_FB_MP................................................................................................................................... 171 7.3.7  F_FB_RNG_4 and F_FB_RNG_16............................................................................................ 174 7.4  Configuration in WinCC flexible ................................................................................................ 179 8  Commissioning a project........................................................................................................................ 181 8.1  Using an existing project........................................................................................................... 181 8.2  Operating modes....................................................................................................................... 181 8.3  Available data channels ............................................................................................................ 182 8.4  Preparing and backing up a project .......................................................................................... 183 8.4.1  Overview ................................................................................................................................... 183 8.4.2  Transfer..................................................................................................................................... 183 8.4.2.1  Overview ................................................................................................................................... 183 8.4.2.2  Starting manual transfer............................................................................................................ 184 8.4.2.3  Starting backtransfer................................................................................................................. 185 8.4.3  Testing a project........................................................................................................................ 186 8.4.4  Backup and restore ................................................................................................................... 187 8.4.4.1  Overview ................................................................................................................................... 187 8.4.4.2  Backing up with WinCC flexible ................................................................................................ 188 8.4.4.3  Restoring with WinCC flexible................................................................................................... 189 8.4.4.4  Backing up with ProSave .......................................................................................................... 190 8.4.4.5  Restoring with ProSave............................................................................................................. 190 8.4.5  Updating the operating system ................................................................................................. 191 8.4.5.1  Overview ................................................................................................................................... 191 8.4.5.2  Updating the operating system using WinCC flexible............................................................... 192 8.4.5.3  Updating the operating system using ProSave......................................................................... 193 8.4.6  Restoring factory settings.......................................................................................................... 194 8.4.6.1  Overview ................................................................................................................................... 194 8.4.6.2  Restoring the factory settings using WinCC flexible................................................................. 194 8.4.6.3  Restoring the factory settings with ProSave ............................................................................. 197 8.5  Commissioning an RFID tag ..................................................................................................... 199 8.6  Replacing an RFID tag.............................................................................................................. 202 9  Commissioning the plant........................................................................................................................ 203 9.1  Overview ................................................................................................................................... 203 9.2  Acceptance of the plant............................................................................................................. 203 9.3  Diagnostics................................................................................................................................ 204 PRELIMINARY II 1.7.2010
  Table of contents   Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  11 10  Fail-safe operation................................................................................................................................. 207 10.1  Organizational measures ...........................................................................................................207 10.2  Switch-off behavior ....................................................................................................................208 10.3  Integrating the HMI device.........................................................................................................209 10.4  Logging onto a machine.............................................................................................................210 10.5  Logging off the machine.............................................................................................................212 10.6  Removing the HMI device..........................................................................................................213 11  Operating a project ................................................................................................................................ 215 11.1  Starting the project.....................................................................................................................215 11.2  Operator input options ...............................................................................................................217 11.3  Direct keys .................................................................................................................................219 11.4  Setting the project language ......................................................................................................220 11.5  Operating the screen keyboard in the project............................................................................220 11.6  Device-specific displays.............................................................................................................224 11.6.1  Overview ....................................................................................................................................224 11.6.2  Showing the battery charge .......................................................................................................224 11.6.3  Displaying WLAN quality............................................................................................................225 11.6.4  Displaying the "Effective range name (RFID)" object ................................................................226 11.7  Project security ..........................................................................................................................226 11.7.1  Overview ....................................................................................................................................226 11.7.2  User View...................................................................................................................................228 11.7.3  User logon..................................................................................................................................230 11.7.4  User logoff..................................................................................................................................231 11.7.5  Creating users............................................................................................................................231 11.7.6  Changing user data....................................................................................................................233 11.7.7  Deleting users ............................................................................................................................234 11.8  Error cases in the project operation...........................................................................................235 11.9  Closing the project .....................................................................................................................236 12  Service and maintenance ...................................................................................................................... 237 12.1  Maintenance and care ...............................................................................................................237 12.2  Replacing the rechargeable buffer battery.................................................................................238 12.3  Spare parts and repairs .............................................................................................................239 PRELIMINARY II 1.7.2010
Table of contents      Wireless Teach Pendant F IWLAN V2 12 Operating Instructions, 08/2010, A5E02453837-01 13  Technical specifications......................................................................................................................... 241 13.1  Dimension drawings.................................................................................................................. 241 13.1.1  Wireless Teach Pendant F IWLAN ........................................................................................... 241 13.1.2  Docking station.......................................................................................................................... 242 13.1.3  RFID tag.................................................................................................................................... 243 13.2  Specifications ............................................................................................................................ 244 13.2.1  Wireless Teach Pendant F IWLAN V2...................................................................................... 244 13.2.2  Interface description.................................................................................................................. 246 13.2.3  Rechargeable batteries............................................................................................................. 248 13.2.4  Docking station.......................................................................................................................... 249 13.2.5  Charger ..................................................................................................................................... 249 13.2.6  RFID tag.................................................................................................................................... 250 13.2.7  F-FBs and configuration............................................................................................................ 250 A  Appendix................................................................................................................................................ 251 A.1  ESD guideline ........................................................................................................................... 251 A.2  Typical operating procedures and potential fault scenarios...................................................... 253 A.2.1  Overview ................................................................................................................................... 253 A.2.2  Switch on the HMI device.......................................................................................................... 254 A.2.3  Integrating the HMI device ........................................................................................................ 255 A.2.4  Communication error for the integrated HMI device ................................................................. 256 A.2.5  Discrepancy error during enabling ............................................................................................ 258 A.2.5.1  The enabling button is askew ................................................................................................... 258 A.2.5.2  The enabling button is defective. .............................................................................................. 259 A.2.6  Logging onto a machine............................................................................................................ 260 A.2.7  Leaving a protection zone without logging off........................................................................... 262 A.2.8  Communication errors with logged on HMI device ................................................................... 263 A.2.9  Logging off the machine............................................................................................................ 264 A.2.10  Removing the HMI device......................................................................................................... 265 A.2.11  Switching off the HMI device..................................................................................................... 266 A.3  Example of an application......................................................................................................... 267 A.3.1  Configuration and operation...................................................................................................... 267 A.3.2  Configuring the controller and HMI device in STEP 7 .............................................................. 270 A.3.3  Safety program S7 Distributed Safety....................................................................................... 274 A.4  Safety-related messages .......................................................................................................... 279 A.5  System alarms .......................................................................................................................... 283 B Abbreviations......................................................................................................................................... 317  Glossary ................................................................................................................................................ 319  Index...................................................................................................................................................... 327 PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  13 Overview 11.1 Product overview Additional application scenarios with Wireless Teach Pendant F IWLAN  The Wireless Teach Pendant F IWLAN offers the option of implementing mobile safety functions ("EMERGENCY STOP" and "Enabling") anywhere in the plant. The HMI device communicates with the F-CPU via WLAN. The operator can operate the plant without disturbing cables. Safety-related control and monitoring in the fail-safe mode occurs within a protection zone on a machine that is logged onto the Wireless Teach Pendant F IWLAN. The Wireless Teach Pendant F IWLAN is characterized by short commissioning times, a large user memory and high performance, and is optimized for projects based on WinCC flexible. Wireless Teach Pendant F IWLAN has the following features: ●  Safety-related operator controls: –  EMERGENCY STOP button –  Enabling button ●  Wireless operation with: –  IWLAN interface via PROFINET –  RFID –  Rechargeable battery ●  6.5" TFT screen with 65536 colors ●  Extended HMI functions 1.2 Scope of delivery The scope of delivery includes:  ●  1 Wireless Teach Pendant F IWLAN with built-in buffer battery ●  1 main rechargeable battery ●  1 neck strap ●  1 grip strap ●  1 data medium PRELIMINARY II 1.7.2010
Overview   1.3 Wireless Teach Pendant F IWLAN  Wireless Teach Pendant F IWLAN V2 14 Operating Instructions, 08/2010, A5E02453837-01 1.3 Wireless Teach Pendant F IWLAN Front view and side view   ①  Rotary switch ②  EMERGENCY STOP button ③  Illuminated pushbutton ④  Display with touch screen ⑤  LED display ⑥  Carrying strap  ⑦  Safety bar ⑧  Membrane keyboard ⑨  Enabling button ⑩  Grip straps, left or right on the HMI device for securing  PRELIMINARY II 1.7.2010
 Overview  1.3 Wireless Teach Pendant F IWLAN Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  15 Wireless Teach Pendant F IWLAN is available in six models. The models are distinguished by a different labeling on the membrane keyboard in the following languages: ●  Japanese ●  English ●  French ●  Chinese ●  Czech ●  Russian The Wireless Teach Pendant F IWLAN works wirelessly on battery power, or it can be mounted in the docking station. Rear view   ①  Tray foot ②  Nameplate  ③  USB port with cover ④  Cover for connection compartment ⑤  Safety bars ⑥  Enabling button ⑦  Battery compartment cover PRELIMINARY II 1.7.2010
Overview   1.4 Main rechargeable battery  Wireless Teach Pendant F IWLAN V2 16 Operating Instructions, 08/2010, A5E02453837-01 1.4 Main rechargeable battery  ①  Ribbon ② Nameplate ③  Button to switch on the LED display ④  Contact side ⑤  LED display 1.5 Accessories The accessory can be ordered from the Internet at Industry Mall (http://mall.automation.siemens.com). ●  Main rechargeable battery  The main rechargeable battery supplies power to the HMI device. Order number: 6AV6645-7BF26-0TA0 ●  Protective foil The protective foil prevents the touch screen from becoming scratched or soiled. The set contains 10 protective foils. Order number: 6AV6645-7BF25-0TA0 ●  Memory card  Only use SD memory cards that have been tested and approved for used by Siemens AG for the Wireless Teach Pendant F IWLAN.    Note The MicroMemory card of the SIMATIC S7 controller is not suited for use with this HMI device.  Order number: 6AV6671-1CB00-0TA0 ●  USB Flash drive for SIMATIC PC  The USB Flash drive for SIMATIC PC is a mobile data storage device with a high data throughput, designed for industrial use. PRELIMINARY II 1.7.2010
 Overview   1.6 Equipment for HMI device and plant Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  17 1.6 Equipment for HMI device and plant 1.6.1 Overview The following devices are needed for the HMI device and for fail-safe operation of a plant: ●  HMI device –  Docking station –  Charger –  Power supply unit ●  Plant –  RFID tag –  Access point –  Signal lamp, optional –  Security systems, optional The devices listed are not included in the scope of delivery of the HMI device. Order these devices separately. You can find order information on the Internet at Industry Mall (http://mall.automation.siemens.com). 1.6.2 Docking station The docking station is used for secure storage of the Wireless Teach Pendant F IWLAN. When the Wirreless Teach Pendant F IWLAN rests in the docking station, the rechargeable batteries. i.e. main battery and backup battery, will be charged. The docking station is not included in the HMI device scope of delivery. The docking station can be ordered with the order number 6AV6645-7BF28-0TA0. PRELIMINARY II 1.7.2010
Overview   1.6 Equipment for HMI device and plant  Wireless Teach Pendant F IWLAN V2 18 Operating Instructions, 08/2010, A5E02453837-01  ①  Retention latch ②  Mounting hole, left and right ③  Charge contact ④  Connection socket for the power unit (on the bottom) Read the relevant documentation. 1.6.3 Charger° The charger is used to charge and store the main batteries for the Wireless Teach Pendant F IWLAN. You can charge one main battery in each of the two charger sections.  NOTICE  Chargers suited for office environments only If you use the charger in ambient conditions that do not correspond to an office environment, malfunctions may occur. Use the charger only in an office environment.  PRELIMINARY II 1.7.2010
 Overview   1.6 Equipment for HMI device and plant Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  19 The charger is not included in the HMI device scope of delivery. The charger is available under the order number 6AV6645-7BF27-0TA0.  ①  Connection socket for the power unit ②  Charging compartment ③  Contact strip ④  LED display Read the relevant documentation. 1.6.4 Power supply unit The power supply unit provides electricity to the docking station and charger. The power supply unit can be used in 120 and 230 V AC power networks. The setting of the voltage range takes place automatically. The output voltage is 24 VDC.  ①  "Power" LED ②  Connecting cable ③  Power supply unit ④  Power supply cable Order number: 6AV6671-5CN00-0TA0 PRELIMINARY II 1.7.2010
Overview   1.6 Equipment for HMI device and plant  Wireless Teach Pendant F IWLAN V2 20 Operating Instructions, 08/2010, A5E02453837-01 The power supply unit is provided with four power supply cables with plugs for the following regions: ●  Europe ●  Asia ●  North America ●  United Kingdom of Great Britain and Northern Ireland Read the relevant documentation. 1.6.5 RFID tag The RFID tag is required to log onto a machine. The RFID tag is a MDS D100 mobile data storage unit.  Order number: 6GT2600-0AD10 The RFID tag includes the following accessories: ●  Spacer Order number: 6GT2190-0AA00 ●  Fixing pocket Order number: 6GT2190-0AB00 $EVWDQGVKDOWHU%HIHVWLJXQJVWDVFKH PRELIMINARY II 1.7.2010
 Overview   1.6 Equipment for HMI device and plant Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  21 1.6.6 Access point The access point is needed for the WLAN. The access point serves as a gateway between the wireless and wired network.  To use the function iPCF-MC for Rapid Roaming, you need an access point with two radio interfaces of the type SCALANCE W78x-2RR and firmware version V4.3. We recommend the following access points for operation with the HMI device.  Designation  Number of WLAN interfaces Antenna  iPCF-MC / Rapid roaming Order number SCALANCE W784-1 1  External  No  6GK5 784-1AA30-2AA0 6GK5 784-1AA30-2AB0 1) SCALANCE W786-1PRO 1  Internal  No  6GK5 786-1BA60-2AA0 6GK5 786-1BA60-2AB0 1) SCALANCE W786-2RR 2  Internal  Yes  6GK5 786-2BA60-6AA0 6GK5 786-2BA60-6AB0 1) SCALANCE W788-1PRO 1  External  No  6GK5 788-1AA60-2AA0 6GK5 788-1AA60-2AB0 1) SCALANCE W788-2RR 2  External  Yes  6GK5 788-2AA60-6AA0 6GK5 788-2AA60-6AB0 1) SCALANCE W786-1PRO 1  Internal  No  6GK5 786-1BA60-2AA0 6GK5 786-1BA60-2AB0 1) SCALANCE W786-2RR 2  Internal  Yes  6GK5 786-2BA60-6AA0 6GK5 786-2BA60-6AB0 1) SCALANCE W786-2RR 2  External  Yes  6GK5 786-2AA60-6AA0 6GK5 786-2AA60-6AB0 1)   1)  US version Read the relevant documentation. PRELIMINARY II 1.7.2010
Overview   1.7 Communication and approved controllers  Wireless Teach Pendant F IWLAN V2 22 Operating Instructions, 08/2010, A5E02453837-01 Additional access points and WLAN products are available in the Internet at: Industry Mall (http://mall.automation.siemens.com) 1.7 Communication and approved controllers Number of communication connections   Communication link  Wireless Teach Pendant F IWLAN V2 Quantity, max.  6 Approved PLCs   NOTICE  Safety-related communication A non-fail-safe controller cannot ensure safety-related communication. A SIMATIC S7F PLC is required for safety-related communication.  Approved protocols  The HMI device uses the following protocols for communication with the controller: ●  PROFINET ●  PROFIsafe Mode V2.0 1.8 Software requirements You need the following software for fail-safe operation:  ●  WinCC flexible 2008, SP2 ●  STEP 7 V5.4, as of SP2 ●  "SIMATIC S7 Distributed Safety V5.4" as of SP3 option package ●  Customer-specific WinCC flexible 2008 SP2 add-on for the Wireless Teach Pendant F IWLAN PRELIMINARY II 1.7.2010
 Overview  1.9 Supported WinCC flexible objects Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  23 1.9 Supported WinCC flexible objects The following tables contain the maximum number of objects you can use with the HMI device in a project.   Note The maximum number of multiple objects used simultaneously can affect the performance of the active WinCC flexible project.  Alarms   Object  Specification  HMI device Number of discrete alarms  4 000  Number of analog alarms  200 Length of the alarm text  80 characters Number of tags in an alarm  Max. 8 LEDs  Alarm line, Alarm window, Alarm view Acknowledge error alarms individually  Yes Acknowledge several error alarms simultaneously (group acknowledgment of alarm groups) 16 alarm groups Edit alarm  Yes Alarm Alarm indicator  Yes ALARM_S  Display S7 alarms  Yes Alarm buffer capacity  512 alarms Simultaneously queued alarm events  Max. 250 View alarm  Yes Delete alarm buffer  Yes Alarm buffer, retentive Line-by-line printing of alarms  Yes Tags, values and lists   Object  Specification  HMI device Tag  Number  2 048 Limit value monitoring  Input/Output  Yes Linear scaling  Input/Output  Yes Text list  Number  500 1) Graphics list  Number  400 1)   1)  The maximum total of text and graphics lists is 500.  PRELIMINARY II 1.7.2010
Overview   1.9 Supported WinCC flexible objects  Wireless Teach Pendant F IWLAN V2 24 Operating Instructions, 08/2010, A5E02453837-01 HMI screens    Object  Specification  HMI device Number  500 Fields per screen  200 Tags per screen  200 Complex objects per screen (for example bars) 10 Screen Template  Yes Recipes    Object  Specification  HMI device Number  300 Data records per recipe  500 Entries per recipe  1 000 Recipe memory  64 KB Recipe Location1)  Memory card USB stick Network drive   1)  The number of recipe data records might be restricted by the capacity of the storage medium. Logs  NOTICE  Logging The HMI device is suitable for logging small volumes of data. The use of a large circular log has a negative effect on performance. In order to log larger amounts of data, use segmented circular logs with multiple sequential logs.  Object  Specification  HMI device Number of logs  20 Number of partial logs in a segmented circular log 400 Entries in each log including all partial logs  10 000 Filing format  CSV with ANSI character set Logs Location1)  Memory card USB stick Network drive   1)  The number of entries in the log may be restricted by the capacity of the storage medium. PRELIMINARY II 1.7.2010
 Overview  1.9 Supported WinCC flexible objects Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  25 Safety   Object  Specification  HMI device Number of user groups  50 Number of users  50 User administration Number of authorizations  32 Infotexts   Object  Specification  HMI device Length (no. of characters)  320  (depending on font) For alarms  Yes For screens  Yes Infotext For screen objects (for example for I/O field, switch, button, invisible button) Yes Additional functions   Object  Specification  HMI device Monitor setting  Touch screen calibration Brightness setting Yes Yes Language change  Number of languages  16 User-specific extension of the functionality  Yes VBScript Number of scripts  50 Graphics objects  Vector and pixel graphics  Yes Trends  Number  300 Task planner  Number of tasks  48 Text objects  Number  10 000 Direct keys  PROFINET IO direct keys  Yes Device-specific functions   Object  Specification  HMI device Main rechargeable battery  Showing the battery charge  Yes WLAN quality  Displaying WLAN quality  Yes Effective range (RFID) name  Display effective range name  Yes PRELIMINARY II 1.7.2010
Overview   1.10 Configuration and process control phases  Wireless Teach Pendant F IWLAN V2 26 Operating Instructions, 08/2010, A5E02453837-01 Functions for RFID tag system   Configuration Number of RFID tags in the project, maximum  127 Number of effective ranges in the project, maximum  127 Number of RFID tags per effective range, maximum  127 Number of HMI devices with logon authorization per effective range, when using F_FB_RNG_4 1), maximum 4 HMI devices Number of devices with logon authorization per effective range, when using F_FB_RNG_16 1), maximum 16 HMI devices   1)  F_FB: Fail-safe function block 1.10 Configuration and process control phases You must follow the phases below in order to use an HMI device in the system: ●  Configuration phase ●  Process control phase Configuration phase  The configuration phase consists of the following operations: ●  Create project ●  Transferring a project ●  Accept project – determine checksum ●  Test project ●  Simulate project ●  Save project &RQILJXUDWLRQ3&6DIHW\UHODWHGSURMHFW:LUHOHVV7HDFK3HQGDQW),:/$1 Process control phase The process control phase includes operation and monitoring of active production processes with the HMI device. The HMI screens on the HMI device visualize the production process. PRELIMINARY II 1.7.2010
 Overview  1.11 Areas in the RFID tag system Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  27 The following figure shows an example configuration of a plant control system which is operated with a Wireless Teach Pendant F IWLAN. 6DIHW\UHODWHGGHYLFHV6,0$7,&6)31'3352),1(7,2FRQWUROOHU6WDQGDUG+RVW3/&352),1(7,2FRQWUROOHU(7b6VWDWLRQZLWK,031,2352),1(7,2GHYLFH:LUHOHVV7HDFK3HQGDQW),:/$1352),1(7,2GHYLFH352),1(76&$/$1&(:$FFHVV3RLQW6,0$7,&6) 1.11 Areas in the RFID tag system The following areas are available in a plant for fail-safe operation with RFID tag logon: ●  WLAN for communication between a fail-safe controller and HMI device ●  Effective range of the RFID tag for logging onto a machine ●  RFID transmission and reception range of an HMI device for logging onto a machine WLAN/iWLAN  Fail-safe controller and HMI device communicate over the radio cell of the access point. The access point serves as a gateway between the wireless and wired network. The WLAN or iWLAN in the plant is provided by at least one access point. The figure below shows an example of the various areas. PRELIMINARY II 1.7.2010
Overview   1.11 Areas in the RFID tag system  Wireless Teach Pendant F IWLAN V2 28 Operating Instructions, 08/2010, A5E02453837-01  352),VDIH ①  SCALANCE W access point ②  Cell of the access point ③  Fail-safe controller ④  Signal lamp ⑤  RFID tag with effective range ⑥  Plant ⑦  Protection zone limit of protection zone 1 ⑧  Protection zone limit of protection zone 2 ⑨  WLAN of the HMI device ⑩  Docking station ⑪  RFID transmission and reception range of the HMI device ⑫  HMI device RFID tag with effective range  The RFID tag is a storage device for a configured ID. The ID of the RFID tag is required for a HMI device to log onto a machine. The RFID transmission and reception range of the HMI device is brought into the effective range of the RFID tag in order to log on. A signal lamp indicates whether an HMI device is logged onto a machine. PRELIMINARY II 1.7.2010
 Overview  1.12 Rapid roaming Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  29 Protection zone  The protection zone is the area in the plant in which one or more machines are operated in fail-safe mode. The protection zone of the plant is demarcated by a security system and organizational measures. The protection zone is not an object that can be configured. Security system and organizational measures  The security system consists of one or more technical protection devices for the protection zone, e.g.: ●  Mesh fence with access ●  Light barrier ●  Contact pressure mat The security system can be controlled by a safety program, such as a program for robot control conforming to a robotics directive. 1.12 Rapid roaming The wireless range of an iWLAN system can be expanded through the use of multiple access points. If an HMI device moves beyond the range of a SCALANCE W78x and into the range of another SCALANCE W78x, the wireless connection remains intact (roaming).  Capabilities provided by iPCF  In the industrial environment, there are applications that require deterministic behavior for a large number of participants and high data throughput in a cell. In addition, deterministic behavior is required for cell cross-overs with handover times of less than 100 milliseconds. The iPCF extension (Industrial Point Coordination Function) was developed to meet these requirements. iPCF ensures that all data traffic runs in coordinated fashion in a wireless cell, controlled by the access point. It also optimizes the throughput with a high number of participants by avoiding collisions. iPCF also facilitates very fast cell changes.  Special features provided by iPCF-MC  iPCF-MC was designed to enable free-moving participants to exploit the special advantages provided by iPCF, which allows communication independent of an RCoax line or directional antennas. With iPCF-MC, the client looks for potentially suitable access points even when it is receiving iPCF queries from the access point and the existing connection to an access point is functioning correctly. This makes it possible to switch to another access point very quickly if it becomes necessary. Unlike iPCF, with iPCF-MC the handover times do not depend on the number of radio channels in use. PRELIMINARY II 1.7.2010
Overview   1.12 Rapid roaming  Wireless Teach Pendant F IWLAN V2 30 Operating Instructions, 08/2010, A5E02453837-01 The following figure shows an example of a plant with four WLAN areas. 352),VDIH ①  Radio cell of access point 1 ②  Radio cell of access point 2 ③  Radio cell of access point 3 ④  Radio cell of access point 4 ⑤  Plant For rapid roaming with iPCF-MC, you will require a suitable access point – see section "Access point (Page 21)". We always recommend that you activate iPCF or iPCF-MC mode for PNIO communication. PRELIMINARY II 1.7.2010
 Overview  1.12 Rapid roaming Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  31 For stable PNIO communication, a WLAN client should be located at all times in a radio cell with a signal strength > 60% or > -65 dBm. This can be checked by switching the various segments on and off. This does not mean that the client needs to change over at a signal strength < 60% or < -65 dBm. Make sure that a segment is available with a sufficiently powerful signal. Limitations due to iPCF-MC iPCF-MC is an in-house development of the Siemens AG that will only work with participants in which iPCF-MC has been installed. Operating principle of iPCF-MC iPCF-MC uses both radio interfaces of the access point differently: One interface works as management interface and sends a beacon every five milliseconds. The other interface transmits the user data. The following requirements have to be met to use iPCF-MC: ●  All "RR" versions of the SCALANCE W-700 access points with at least two WLAN interfaces can be used as access point. The HMI device and all SCALANCE W-700 "RR" versions are suited as clients. ●  You have to operate the management interface and the data interface in the same frequency band; they also have to match in their radio coverage. iPCF-MC will not work if both radio interfaces are equipped with directional antenna the cover different areas. ●  The management inferfaces of all access points that a client is to access must use the same channel. A client will only scan this one channel to find all available access points. ●  You cannot use the transmission method to IEEE 802.11h for the management interface. 802.11h is possible for the data interface. PRELIMINARY II 1.7.2010
Overview   1.13 Terms for fail-safe operation  Wireless Teach Pendant F IWLAN V2 32 Operating Instructions, 08/2010, A5E02453837-01 1.13 Terms for fail-safe operation Fail-safe automation system  A fail-safe automation system is required in a plant with high safety requirements.  In an EMERGENCY STOP, the fail-safe automation system brings the plant to a safe operating state regardless of the situation. Shutdown of the plant therefore does not pose a danger to people or the plant.  Fail-safe operation  The HMI device registers signals from the EMERGENCY STOP button and the enabling button during fail-safe operation. The controller and the HMI device communicate via PROFIsafe. Configuration of the safety functions in STEP 7 with the "SIMATIC S7 Distributed Safety" add-on package can achieve fail-safe operation according to SIL 3 or Performance Level e and Category 4 for the HMI device. Integration and removal  ●  Integrating Integration means to establish safety-related communication between the HMI device and the fail-safe controller via PROFIsafe. The EMERGENCY STOP button is enabled in integrated operating mode. ●  Removing Removal means to intentionally stop safety-related communication between the HMI device and the fail-safe controller via PROFIsafe. Logging on the HMI device  The HMI device must be logged onto a machine in order to operate the machine after integration in fail-safe operation with the enabling button. The logon is performed with an RFID tag. Logging off an HMI device  Logging off an HMI device from a machine terminates fail-safe operation with the enabling button. ●  Forced logoff  If the security system is triggered, for example by the operator leaving the protection zone without logging off, a forced logoff is performed by the machine. The HMI device revokes the operator authorization for the enabling button. The operator is prompted to confirm the "Forced logoff" dialog. ●  Automatic logoff in the event of a communication error  PRELIMINARY II 1.7.2010
 Overview  1.13 Terms for fail-safe operation Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  33 If a communication error occurs, the HMI device is removed from the safety-related communication. The HMI device is automatically logged off the machine. The fail-safe controller brings the plant to a safe operating state. Shutdown response of the plant ●  The following shutdown response of the plant applies regardless of whether or not the HMI device is logged onto a machine. –  EMERGENCY STOP  EMERGENCY STOP is a procedure that is intended to stop a process or movement associated with danger in accordance to EN 60204-1, Appendix D. An EMERGENCY STOP immediately stops all parts of the plant controlled by the fail-safe controller via a safety program. The EMERGENCY STOP button is always enabled when there is PROFIsafe communication between HMI device and fail-safe controller, i.e. when the HMI device is integrated in the PROFIsafe communication. –  Global rampdown  A global rampdown is the intentional stopping of the plant. The global rampdown is independent of the area.  The global rampdown is triggered by the fail-safe controller, for example, if an error occurs with an HMI device integrated in the PROFIsafe communication. ●  The following shutdown response of the plant applies when the HMI device is logged onto a machine. –  Local rampdown  A local rampdown is the intentional stopping of a plant section by the fail-safe controller. The local rampdown is triggered, for example, when the operator leaves the protection zone without logging off via a security system. –  Shutdown  The shutdown is triggered when the F-CPU has detected a communication error with an HMI device that is logged onto a machine. Shutdown is the immediate stop of all machinery being operated in fail-safe mode. Communication error A communication error occurs when the communication between HMI device and fail-safe controller is interrupted. Additional information is available in the section "Communication error for the integrated HMI device (Page 256)".  PRELIMINARY II 1.7.2010
Overview   1.13 Terms for fail-safe operation  Wireless Teach Pendant F IWLAN V2 34 Operating Instructions, 08/2010, A5E02453837-01 PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  35 Safety instructions and standards 22.1 Safety instructions  WARNING  Injury or material damage If you do not exactly adhere to the safety regulations and procedural instructions contained in this manual, hazards may arise and safety features be rendered ineffective. This can result in personal injuries or material damage. Closely follow closely the safety regulations and procedural instructions in each situation.  Observe the regulations for safety and accident prevention applicable to your application in addition to the safety instructions given in this manual. Project security  WARNING  Injury or material damage The configuration engineer for plant control must take precautions to ensure that an interrupted program will be correctly integrated again after communication failures, voltage dips or power outages. A dangerous operating state must not be allowed to occur - not even temporarily - during the entire execution of the control program, even during a troubleshooting.   Safety during commissioning and operation   WARNING  Installation according to the instructions Commissioning of the HMI device is prohibited until it has been absolutely ensured that the machine to be operated with the HMI device complies with Directive 2006/42/EC. Verify before commissioning that the provisions of Directive 2006/42/EC are fulfilled.  PRELIMINARY II 1.7.2010
Safety instructions and standards   2.2 Approvals  Wireless Teach Pendant F IWLAN V2 36 Operating Instructions, 08/2010, A5E02453837-01 Safety during operation  WARNING  HMI device failure A strong shock or impact can impede the functionality of the HMI device. After a strong mechanical action, ensure the HMI device and the safety-related parts are in working order. Danger of injury Manual movements controlled with the HMI should only be executed in conjunction with the enabling buttons and at reduced velocity. Exclusive operating right The simultaneous operation of the plant with multiple HMI devices is not allowed. Prevent simultaneous operation through the appropriate configuration.   Note The function of the EMERGENCY STOP button must be checked periodically. High-frequency radiation, for example from cellular phones, can lead to undesirable operating states in a plant.   2.2 Approvals   Note The following overview shows possible approvals. The only valid approvals for the HMI device, the docking station, the power supply module and the RFID tag are those shown on the label on the rear panel.  CE approval  The HMI device, the docking station, the power supply and the RFID tag conform to the European standards for programmable logic controllers as published in the official journals of the European Union: ●  2004/108/EC "Electromagnetic Compatibility" (EMC Directive) ●  1999/5/ECG "Directive of the European Parliament and of the Council from March 9, 1999 relating to Radio Equipment and Telecommunications Terminal Equipment and the Mutual Recognition of their Conformity" PRELIMINARY II 1.7.2010
 Safety instructions and standards  2.2 Approvals Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  37 EC Declaration of Conformity  The EC Declarations of Conformity are available to the relevant authorities at the following address: Siemens AG Industry Sector I IA AS RD ST PO Box 1963 92209 Amberg Germany UL approval  Underwriters Laboratories Inc. in accordance with:  ●  UL 60950 (Safety of Information Technology Equipment) ●  CAN/CSA-C22.2 No. 60950-00 (Safety of Information Technology Equipment) Requirements of the approval are only met if the device is operated with the main rechargeable battery or in stationary mode in the docking station. Marking for Australia  The HMI device, the docking station, the power supply module and the RFID tag meet requirements to AS/NZS 2064 (Class A). Wireless approval  The national approvals for the HMI device are listed on the back of the device and in the product information for "Wireless Teach Pendant F IWLAN" in the Internet (http://support.automation.siemens.com/WW/view/en/30360848/133300). Requesting certificates  A copy of the certificates and associated reports is available upon request from the following address: Siemens AG Industry Sector I IA AS RD ST PO Box 1963 92209 Amberg Germany PRELIMINARY II 1.7.2010
Safety instructions and standards   2.3 Standards on operating safety  Wireless Teach Pendant F IWLAN V2 38 Operating Instructions, 08/2010, A5E02453837-01 2.3 Standards on operating safety The HMI device meets the following standards for use in a plant:  Standard  Title  Version EN 12417  Machine Tools - Safety - Machining Centres  01.07.2009 EN 60950  Information Technology Equipment (General Requirements) 01.11.2006 UL 60950  Safety of Information Technology Equipment  11.12.2000 CAN/CSA-C22.2 No. 60950-00 Safety of Information Technology Equipment  01.12.1990 EMC testing   The values of the EMC test for the HMI device conform to the following standards:  Standard  Title  Version EN 61000-6-2  EMC – Part 6-2: Generic standards - Immunity for industrial environments 01.05.2006 EN 61000-6-4  EMC – Part 6-4: Generic standards - Emission standard for industrial environments 01.11.2007 DIN EN 50360  Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human safety in electromagnetic fields (300 MHz to 3 GHz) 01.05.2002 DIN EN 50371  Generic standard to demonstrate compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) 01.11.2002 DIN EN 61131-2  Programmable Logic Controllers – Part 2: Equipment requirements and testing 01.01.2009 DIN EN 300440-1  Electromagnetic compatibility and radio spectrum matters 01.08.2009 DIN EN 301893  Broadband Radio Access Networks (BRAN)  01.05.2009 EN 50385   Product standard to demonstrate the compliance of radio base stations and fixed terminal stations for wireless telecommunication systems 01.05.2003 EN 300328  Electromagnetic compatibility and radio spectrum matters 01.03.2009 EN 300330  Electromagnetic compatibility and radio spectrum matters (ERM) 01.08.2006 EN 301489-1   Electromagnetic compatibility and radio spectrum matters (ERM) 01.01.2010 EN 301489-3   Electromagnetic compatibility and radio spectrum matters (ERM) 01.01.2003 EN 301489-17  Electromagnetic compatibility and radio spectrum matters 01.07.2009 FCC   OET 65, RSS-210, Part 15247, 15407 radio authorization  FCC  RFID 15225, RSS 210   PRELIMINARY II 1.7.2010
 Safety instructions and standards  2.4 Operating conditions Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  39 TÜV  The TÜV confirms that the HMI device satisfies the requirements of the following standards with regard to its safety functions.  Standard  Title  Version DIN EN 60204-1  Safety of machinery – Electrical equipment of machines – Part 1: General Requirements 01.10.2009 DIN IEC 62061  Safety of machinery – Functional safety of electrical, electronic and programmable control systems for machinery 01.04.2009 IEC 61508-1 to 4  Safety Integrity Level 3  01.01.2005 ISO 13850  Safety of machinery - EMERGENCY STOP - Principles for design 01.01.2009 ISO 13849-1  Performance Level e and Category 4  01.09.2009 Additional measurements Additional measurements were made for: ●  Japan –  Table/Annex No 43,44,45 – Test Method for Radio Equipment mentioned in Certification Regulations Article, Item 19, 19-2, 19-3 and 19-3-2 –  Table/Annex No 47 – Test Method for Radio Equipment mentioned in Certification Regulations Article, Item 19-5 and 19-11 –  RFID – ARIB STD T-82 ●  Taiwan –  LP0002 2.4 Operating conditions The national approvals for the HMI device are listed on the back of the device and in the product information for "Wireless Teach Pendant F IWLAN V2" in the Internet (http://support.automation.siemens.com/WW/view/en/30360848/133300).  NOTICE  Wireless control device A wireless control device may cause interference. If a wireless control device is used, the following must be ensured:  That other systems at the site are not disturbed by the wireless control device  That other systems at the site do not disturb the wireless control device  PRELIMINARY II 1.7.2010
Safety instructions and standards   2.5 Risk analysis of the plant  Wireless Teach Pendant F IWLAN V2 40 Operating Instructions, 08/2010, A5E02453837-01 Use in industry  The HMI device is designed for industrial use. For this reason, the following standards are met: ●  Interference emission requirements, paragraph 7.3, DIN EN 60947-1, Environment A ●  Interference immunity requirements DIN EN 61326 Residential use   NOTICE  Interference to radio and TV reception The HMI device is not suitable for use in residential areas: Operation of HMI devices in residential areas can cause interference to radio and television reception. If the HMI device is used in a residential area, you must take measures to achieve Limit Class B conforming to EN 55016 for RF interference.  To achieve radio interference suppression class B, for example, install filters in power supply lines. Individual acceptance is required.  2.5 Risk analysis of the plant The following rules apply to the risk analysis of the plant:  ●  ISO 12100-1 and ISO 12100-2, General design guidelines for machines ●  ISO 13849-1, Safety of machinery - Safety-related parts of control systems - General principles for design ●  ISO 14121-1, Safety of machinery – Risk assessment – Part 1: Principles These considerations result in a performance levels a to e in accordance with ISO 13849-1, which dictate how the safety-related parts of the system must be furnished. The safety-related parts of the HMI device meet: ●  SIL 3 in accordance with IEC 61508 ●  Performance level e and Category 4 in accordance with ISO 13849-1 Take the plant configuration as a whole into consideration in the risk analysis and not just the separate sections. For additional information on risk analysis and risk mitigation, refer to the "Safety Technology in SIMATIC S7" system manual (http://support.automation.siemens.com/WW/view/en/12490443).  See also Safety-related operator controls (Page 88) PRELIMINARY II 1.7.2010
 Safety instructions and standards   2.6 Safety functions of the EMERGENCY STOP button Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  41 2.6 Safety functions of the EMERGENCY STOP button The EMERGENCY STOP button on the HMI device brings about a safety-related stop of the plant in accordance with IEC 60204-1, Section 9.2.5.3. You can implement a Category 0, 1, or 2 stop function in accordance with IEC 60204-1, Section 9.2.2. The stop function category must be selected on the basis of a risk assessment.  The following requirements must be met in order to render the EMERGENCY STOP button effective:  ●  The HMI device must be operated in the docking station or with the main rechargeable battery. ●  A project is running on the HMI device. ●  The HMI device must be integrated in the safety program of the F-CPU. If these prerequisites are satisfied the following applies: ●  The "SAFE" LED on the HMI device is lit. ●  The EMERGENCY STOP button is enabled. As soon as the PROFIsafe communication between the HMI device and controller is established within the WLAN range, the EMERGENCY STOP button on the HMI device becomes active. The EMERGENCY STOP button is enabled within the WLAN regardless of whether or not the HMI device is logged onto a machine.  WARNING  EMERGENCY STOP button not available  The EMERGENCY STOP button on the HMI device may not used as a replacement for a permanently-wired EMERGENCY STOP or EMERGENCY OFF on the machine. Install stationary EMERGENCY STOP buttons that will be available at all times on the configured system. EMERGENCY STOP button not enabled  If a communication error triggers a global rampdown, the EMERGENCY STOP button will no longer be available on the affected HMI device. You have the option of interconnecting the "Global Rampdown" signal so that an EMERGENCY STOP is triggered. EMERGENCY STOP button out of service when HMI device is removed  If the HMI device is not integrated in the safety program of the F-CPU, the EMERGENCY STOP button will be out of service. To avoid confusion between HMI devices with enabled and disabled EMERGENCY STOP buttons during an emergency, only one integrated HMI device should be freely accessible. If an HMI device is not integrated and not in use, store the HMI device in a location with protected access. Category 0 or 1 Stop  If a Category 0 or 1 stop circuit is implemented, the stop function must be effective regardless of the operating mode. A Category 0 stop must have precedence. Release of the EMERGENCY STOP button must not cause a hazardous situation (see also EN 60204-1, Section 9.2.5.3). The stop function is not to be used as a replacement for safety equipment. PRELIMINARY II 1.7.2010
Safety instructions and standards   2.7 Safety functions of the enabling mechanism  Wireless Teach Pendant F IWLAN V2 42 Operating Instructions, 08/2010, A5E02453837-01   Note The EMERGENCY STOP button is evaluated when the HMI device is integrated in the safety program of the F-CPU. The EMERGENCY STOP button can be triggered unintentionally in the following situations:  If the HMI device falls down  When opening one of the coverings on the rear of the HMI device  2.7 Safety functions of the enabling mechanism In a numerically controlled system, the "Special mode" operating mode requires an enabling mechanism. The enabling mechanism is comprised of two enabling buttons mounted on both sides of the HMI device. Special mode  During special mode, safety has to be ensured in a different manner than in automatic mode. During special mode, personnel enter danger zones of the plant in which controlled movements must be possible. Depending on the risk assessment of the plant, movement needs to occur at reduced speed for special mode. Movement of the plant parts should only be possible when the enabling mechanism is activated. The operator must be accordingly qualified and know details of use in accordance with safety regulations. Safety instructions  The safety-related parts of the controller for speed reduction and those for the enabling mechanism are designed in such a way that they satisfy the requirements for the safety category as determined by the risk assessment. The operating principles of enabling devices are described in EN 60204. Through the findings from accident investigations and the existence of technical solutions, the 3-stage enabling button became state of the art. Positions 1 and 3 of the enabling button are Off functions. Only the middle position allows the enabling function. EN 60204-1 is identical to IEC 60204-1, whereby the 3-stage enabling button is gaining international importance. PRELIMINARY II 1.7.2010
 Safety instructions and standards   2.7 Safety functions of the enabling mechanism Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  43 The Stop category of the enabling device must be selected on the basis of a risk assessment and correspond to a Category 0 or 1 Stop.   WARNING  Injury or material damage Enabling buttons should only be used when the following applies for the person activating the enabling button:  The person can see the danger zone.  The person is capable of recognizing personal injury hazards in good time.  The person is capable of taking immediate measures to avoid danger. The only person allowed to remain in the danger zone is the person who is activating the enabling button. Commands for unsafe conditions are not permitted to be issued with one enabling button alone. To accomplish this, a secondary, conscious start command using a button on the HMI device is required.  NOTICE  Risk from improper use An enabling button can be fixed without permission. To avoid the risk of unauthorized fixation, fully press both enabling buttons each time the project starts. Release the enabling buttons.   Note The enabling button only has an effect when the HMI device is logged onto a machine and the "RNG" LED on the HMI device is lit.  See also Risk analysis of the plant (Page 40) PRELIMINARY II 1.7.2010
Safety instructions and standards   2.8 Electromagnetic compatibility  Wireless Teach Pendant F IWLAN V2 44 Operating Instructions, 08/2010, A5E02453837-01 2.8 Electromagnetic compatibility The HMI device, docking station, power supply and RFID tag meet the requirements of the EMC regulations pertaining to the European domestic market and more. The enhanced testing and limit value levels defined by CDV 61326-3-1/Ed. 1 have been taken into account during the type test EMC-compliant installation  Conditions for fault-free operation include EMC-conform assembly of the docking station and RFID tag, as well as the use of interference-proof cables. The following documents also apply to the installation of the docking station: ●  Description "Directives for interference-free installation of PLCs" (http://support.automation.siemens.com/WW/view/de/1064706), German ●  System manual "Basics on Setting up an Industrial Wireless LAN" (http://support.automation.siemens.com/WW/view/en/9975764) Pulse-shaped disturbance  The following table shows the electromagnetic compatibility of modules with regard to pulse-shaped interference. The table applies to the docking station, with and without an attached HMI device.  Pulse-shaped disturbance  Tested with  Degree of severity Electrostatic discharge in accordance with IEC 61000-4-2 Air discharge: 8 kV Contact discharge: 6 kV 3 Burst pulses (high-speed transient interference) in accordance with IEC 61000-4-4 2 kV supply line  3   An external safety circuit is required for the "Surge immunity test according to IEC 61000-4-5". The safety circuit is described in the Installation manual "Automation System S7-300 – Installation" (http://support.automation.siemens.com/WW/view/en/15390415), section "Lightning and overvoltage protection".   Pulse-shaped disturbance  Tested with  Degree of severity Asymmetrical coupling  2 kV power cable DC voltage with protective elements 3 Symmetrical coupling  1 kV power cable DC voltage with protective elements 3 PRELIMINARY II 1.7.2010
 Safety instructions and standards   2.8 Electromagnetic compatibility Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  45 Sinusoidal interference  The following table shows the EMC behavior of the modules with respect to sinusoidal interference. The table applies to the HMI device, docking station and power supply.  Sinusoidal interference  Test values  Degree of severity HF radiation (in electromagnetic fields) in accordance with IEC 61000-4-3 80% amplitude modulation at 1 kHz  Up to 10 V/m in the 80 MHz to 1 GHz range  Up to 10 V/m in the 1.4 GHz to 2 GHz range  Up to 1 V/m in the 2 GHz to 2.7 GHz range 3 RF interference current on cables and cable shielding conforming to IEC 61000-4-6 Test voltage 10 V, with 80% amplitude modulation of 1 kHz in the 9 kHz to 80 MHz range 3 Emission of radio interference  The following table shows the interference emissions from electromagnetic fields in accordance with EN 55016, Limit Value Class A, Group 1, measured at a distance of 10 m.   30 to 230 MHz  < 40 dB (V/m) quasi-peak 230 to 1 000 MHz  < 47 dB (V/m) quasi-peak    Note Before you connect the HMI device to the public electrical network, ensure that it is compliant with Limit Value Class B in accordance with EN 55022.  PRELIMINARY II 1.7.2010
Safety instructions and standards   2.9 Transport and storage conditions  Wireless Teach Pendant F IWLAN V2 46 Operating Instructions, 08/2010, A5E02453837-01 2.9 Transport and storage conditions The shipping conditions of this HMI device exceed requirements in accordance with IEC 61131-2. The following specifications apply to devices that are shipped and stored in the original packaging.  ●  The mechanical conditions are compliant with IEC 60721-3-2, Class 2M2. The following table shows the transport and storage conditions for the HMI device, docking station, power supply unit and RFID tag.  Type of condition  Permitted range Drop test (in transport package)  ≤ 1 m Temperature  –20 to +60 °C Atmospheric pressure  1140 hPa to 660 hPa, corresponds to an elevation of –1000 to 3500 m Relative humidity  Applies to HMI device: 10 to 90%, without condensation Applies to docking station: 35 to 85%, without condensation Sinusoidal vibration in accordance with IEC 60068-2-6 5 Hz to 9 Hz: 3.5 mm 9 Hz to 500 Hz: 9.8 m/s2 Shock in accordance with IEC 60068-2-29  250 m/s2, 6 ms, 1000 shocks   NOTICE  Equipment failure Moisture in the form of condensation on or in the device is formed:  When transporting a device at low temperatures  Under extreme temperature variations Moisture and condensation lead to malfunction. Bring the device to room temperature before operating. Condensation  When condensation is on the device, do not expose the HMI device to direct radiation from a heater. If condensation has developed, wait approximately 4 hours until the HMI device has dried completely before switching it on.  The following points must be adhered to in order to ensure a fault-free and safe operation of the HMI device: ●  Proper transportation and storage ●  Proper installation and mounting ●  Careful operation and maintenance The warranty for the HMI device will be deemed void if these stipulations are not heeded.  PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  47 Planning the use 33.1 Checklist Perform the following tasks when planning fail-safe operation. Confirm each task by checking it off in the following list.  Task  Additional information  Check Check the ambient conditions at the site. Operating conditions (Page 48)   Plan access routes to the plant.  –   Plan operator locations at the plant where WLAN will be needed. WLAN properties (Page 51)    Plan the WLAN. Determine the installation locations for the access points based on this. Special programs are available for planning the WLAN. We strongly recommend you check the local wireless conditions before beginning start-up. System manual "Basics on Setting up an Industrial Wireless LAN" (http://support.automation.siemens.com/WW/view/en/9975764) "SINEMA E" planning program (http://www.siemens.com/sinema)  Guideline for the Use of Industrial Wireless LAN in a PROFINET IO Environment (http://support.automation.siemens.com/WW/view/en/31938420)  Plan for information security.  Planning information security (Page 59)   Plan the configuration of the PROFINET and PROFIsafe communication. System manual "Communication with SIMATIC" (http://support.automation.siemens.com/WW/view/en/25074283) Programming and operation manual "S7 Distributed Safety - Configuring and Programming" (http://support.automation.siemens.com/WW/view/en/22099875)  Plan the installation locations for the RFID tags. Planning an installation location for RFID tags (Page 54)  Plan the installation location and clearance for the docking station. Planning the installation location and clearance of the docking station (Page 56)   Plan the location for the signal lamps. Planning the installation location of signal lamps (Page 57)  PRELIMINARY II 1.7.2010
Planning the use   3.2 Operating conditions  Wireless Teach Pendant F IWLAN V2 48 Operating Instructions, 08/2010, A5E02453837-01 3.2 Operating conditions Mechanical and climatic ambient conditions The HMI device is designed for use in a location protected from the effects of the weather. The ambient conditions meet the requirements for DIN IEC 60721-3-3: ●  Mechanical requirements according to class 3M3 The following table applies to the HMI device and docking station. ●  Climatic requirements according to class 3K3 Use with additional protective measures  You may only use the HMI device at the following locations with additional protective measures: ●  In locations with a high degree of ionizing radiation ●  In locations with difficult operating conditions, for example due to: –  Corrosive vapors, gases, oils or chemicals –  Electrical or magnetic fields of high intensity ●  In systems that require special monitoring, for example: –  Elevators –  Systems in especially hazardous rooms Damping shock and vibration  If the HMI device is subjected to impermissibly strong shocks or vibrations, you must take appropriate measures to reduce amplitudes or acceleration. In such situations, use vibration damping or vibration absorber systems for the HMI device and accessories.  NOTICE  Setting down the HMI device If you place the HMI device on a surface with a high natural frequency, malfunctions may occur as a result. Do not place the HMI device on a surface with a high natural frequency.  PRELIMINARY II 1.7.2010
 Planning the use  3.2 Operating conditions Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  49 Testing mechanical ambient conditions  The following table provides information on the type and scope of tests for mechanical ambient conditions performed for the HMI device.  Test   Physical variable  Value Vibration  1 octave/min 10 cycles per axis 5 to 8.4 Hz: Deflection 3.5 mm Vibrations IEC 60068-2-6 Test Fc  Frequency band 8.4 to 150 Hz Vibration acceleration 9.8 m/s Shock form  Half sine Shock amplitude  15 g Shock duration  11 ms Shock IEC 60068-2-27 Number of shocks  3 per axis Impact IEC 60068-2-75 Impact stress   1 Nm, once With an impact test device similar to DIN VDE 0740, Part 1, Section 19.2 at room temperature. Drop test EN 60068-2-31 Fall height  0.5 m Applies to the HMI device, with and without battery Climatic ambient conditions for the HMI device  The following table shows the permitted ambient climatic conditions for use of the HMI device.  Ambient condition  Permitted range   Comment Operating temperature  0 to 40° C  – Humidity, relative  5 to 85 %, no condensation Stress level 2, according to IEC 61131-2 Humidity, absolute  1 to 25 g/m3 – Atmospheric pressure  1060 to 700 hPa  Corresponds to an  elevation of –1000 to 2000 m SO2 < 0.5 vpm, relative humidity < 60%, no condensation Test: 10 cm3/m3; 10 days Pollutant concentration H2S < 0.1 vpm, relative humidity < 60%, no condensation Test: 1 cm3/m3; 10 days PRELIMINARY II 1.7.2010
Planning the use   3.3 Insulation resistance, protection class and degree of protection  Wireless Teach Pendant F IWLAN V2 50 Operating Instructions, 08/2010, A5E02453837-01 Ambient climatic conditions for the docking station  The following table shows the permitted ambient climatic conditions for use of the docking station.  Ambient condition  Permitted range   Comment Operating temperature  0 to 40° C  – Humidity, relative  5 to 85%, no condensation Stress level 2, according to IEC 61131-2 Humidity, absolute  1 to 25 g/m3 – Atmospheric pressure  1060 to 700 hPa  Corresponds to an  elevation of –1000 to 2000 m SO2 < 0.5 vpm, relative humidity < 60%, no condensation Test: 10 cm3/m3; 10 days  Pollutant concentration H2S < 0.1 vpm, relative humidity < 60%, no condensation Test: 1 cm3/m3; 10 days  Ambient climatic conditions for the RDIF tag  The following table shows the permitted ambient climatic conditions for use of the RFID tag.  Ambient condition  Permitted range   Comment Operating temperature  –25 to 80° C  – 3.3 Insulation resistance, protection class and degree of protection insulation resistance  Insulation resistance is demonstrated in the type test with the following test voltages in accordance with IEC 61131-2:  Circuits with a nominal voltage of Ue to other circuits or ground Test voltage < 50 V  500 VDC Protection class of the HMI device   HMI device  Protection class according to IEC 60417-DB-HS Front and rear panel  Protection class III PRELIMINARY II 1.7.2010
 Planning the use  3.4 WLAN properties Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  51 Degree of protection of the HMI device   NOTICE  Degree of protection IP65 for HMI device When enclosure openings or the connection compartment are not closed, the HMI device does not meet the specified degree of protection. Ensure that the enclosure is closed as specified by the regulations.   Device  Degree of protection in accordance with IEC 60529 HMI device, front and rear panel  IP65 RFID tag  IP65 3.4 WLAN properties Adhere to the installation guidelines when installing the WLAN. You can find more additional information in the System manual "Basics on Setting up an Industrial Wireless LAN" (http://support.automation.siemens.com/WW/view/en/9975764). Plan the WLAN for a maximum of four HMI devices. When adding a WLAN participant, make sure that you observe the conditions described in the document "Wireless LAN in a PROFINET IO Environment". The conditions vary depending on the operating mode and the requirement for PNIO refresh times. See Guideline for the Use of Industrial Wireless LAN in a PROFINET IO Environment (http://support.automation.siemens.com/WW/view/en/31938420).  NOTICE  Communication interference possible Communication interference cannot be excluded if you do not check the local wireless conditions prior to start-up. Check your local wireless conditions prior to start-up. When planning the wireless channels, mode 802.11a is preferable.  Ad hoc network An ad hoc network cannot be used in conjunction with the HMI device. PRELIMINARY II 1.7.2010
Planning the use   3.5 Planning protection zones in the RFID tag system  Wireless Teach Pendant F IWLAN V2 52 Operating Instructions, 08/2010, A5E02453837-01 3.5 Planning protection zones in the RFID tag system At least one protected area must be set up in an RFID tag system. The protection zone is the area of the plant in which a plant section is operated in fail-safe mode.  The protection zone requires low-barrier access for the operator to the plant section that is located within the protection zone. The HMI device must be logged onto a machine within the protection zone in order to operate the machine after integration in the fail-safe mode with the enabling button.   Note You can also operate the HMI device outside a protection zone without logging onto a machine. However, operation in the fail-safe mode with the enabling button is then not possible.  The following figure shows a plant with a protection zone. 352),VDIH ①  Protection zone limit ②  Plant section in the protection zone ③  RFID tag with effective range PRELIMINARY II 1.7.2010
 Planning the use   3.5 Planning protection zones in the RFID tag system Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  53 Relationship between protection zone and RFID tag The protection zone limit is defined by a clear spatial demarcation. If the HMI device is logged onto a machine in the protected area with a RFID tag, it is possible to operate the machine in fail-safe mode with an enabling button within the protected area. Requirements for the protection zone The protection zone must meet the following requirements:  ●  The protection zone must be completely demarcated and protected. ●  Protection zones may not overlap. ●  The protection zone must be fully visible to the operating personnel. ●  A hazardous location must be visible from every point of the protection zone. You can find a configuration example in the Appendix. ●  The protection zone must be protected by a security system that prevents unauthorized or erroneous use of the HMI device. The security system must have a safety category that is sufficient to meet the plant requirements. The following security systems are suitable:  ●  Mesh fence with access If you use a mesh fence for the protection zone, you can protect access through an additional security system, for example, a light barrier or a contact pressure mat. This allows open access for an escape route during operation of the plant. ●  Light barrier ●  Contact pressure mat The security system can be controlled by a safety program, such as a program for robot control conforming to a robotics directive. See also Example of an application (Page 267) PRELIMINARY II 1.7.2010
Planning the use   3.6 Planning an installation location for RFID tags  Wireless Teach Pendant F IWLAN V2 54 Operating Instructions, 08/2010, A5E02453837-01 3.6 Planning an installation location for RFID tags Installation location for the RFID tag  Observe the following when selecting the RFID tag installation location: ●  You will need at least one RFID tag for each machine operated in fail-safe mode with the enabling button. ●  The installation surface of the RFID tag must have a level foundation. ●  The installation surface must be non-metallic. When mounting on metallic base, a spacer is required. ●  Select an installation location that is clearly visible for the signs of the RFID tags with an associated ID. Influence on communication Note the following: ●  The use of an MDS D100 directly on metal is not permitted. Metal influences the field data and thus the communication. ●  Flush installation of a MDS D100 in metal reduces the field data. ●  Metallic objects must not reduce the effective range. ●  A test is necessary in critical applications. You can find more information in the manual "MOBY D, System Manual, Edition 11/2006". Function of the RFID tag The HMI device uses the RFID tag to log onto a machine within a protected area.  Effective range of the RFID tag  The radius of the effective range of an RFID tag is a maximum of 5 cm. 7UDQVPLVVLRQSRZHU'LVWDQFHFP PRELIMINARY II 1.7.2010
 Planning the use   3.6 Planning an installation location for RFID tags Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  55 Planning the number of RFID tags  The following rules apply in a WinCC flexible project: ●  A maximum of 127 effective ranges can be configured. Specify a name and a plant-wide unique ID for each effective range - in a values range from 1 to 65534. Write down the name and ID of the effective ranges on the plant map for the commissioning. ●  A maximum of 127 RFID tags can be configured for each effective range. The mapping of the protected area to the RFID tag is defined in the project. Planning the RFID tag mapping  The following rules apply: ●  Safe access is required to the RFID tag. ●  The distance between two RFID tags must be at least 10 cm. ●  An RFID tag cannot be assigned to two machines. ●  To log onto a machine, the distance between the HMI device and the RFID tag may not be more than 5 cm. PRELIMINARY II 1.7.2010
Planning the use   3.7 Planning the installation location and clearance of the docking station  Wireless Teach Pendant F IWLAN V2 56 Operating Instructions, 08/2010, A5E02453837-01 3.7 Planning the installation location and clearance of the docking station Selecting the mounting location  The docking station is designed for vertical installation. WARNING  Installing the docking station When the HMI device is operated in the plant and docking station is mounted, the EMERGENCY STOP button must be enabled. The EMERGENCY STOP button is not enabled when the docking station is in a plant area with insufficient wireless coverage. The docking station must be installed in either a plant section with sufficiently wide WLAN coverage or a separate service area. CAUTION  Stopping the plant The HMI device can fall down if it is not securely hooked in. This can accidentally trigger the EMERGENCY STOP button. Install the docking station on a vertical surface or one that is slightly inclined towards the back. The location of the docking station must be free of vibrations. If the docking station vibrates while the HMI device is resting in it, the HMI device may come off. Find a location without vibration for installation of the docking station. For additional information, see Section Operating conditions (Page 48). NOTICE  Charging the rechargeable battery When charging a rechargeable battery, the ambient temperature or battery temperature should not exceed 40 °C. The higher the temperature, the longer it will take for the rechargeable battery to fully charge. Find a place with a cool ambient temperature for the docking station. Select a location with the following characteristics for installing the docking station: ●  Easily and safely accessible ●  No exposure to direct sunlight ●  It is easy to hook in and remove the HMI device in the docking station ●  Ergonomic operation of the HMI device in the docking station is ensured PRELIMINARY II 1.7.2010
 Planning the use   3.8 Planning the installation location of signal lamps Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  57 Maintaining clearances  The following clearance is required around the docking station: $OOGLPHQVLRQVLQPP 3.8 Planning the installation location of signal lamps You will need a signal lamp for a machine operated in fail-safe mode with the enabling button. The signal lamp notifies the operator that he/she has logged on to the machine. Plan a clearly visible installation location for the signal lamp that is assigned to a machine.  PRELIMINARY II 1.7.2010
Planning the use   3.9 Coexistence of the frequency bands  Wireless Teach Pendant F IWLAN V2 58 Operating Instructions, 08/2010, A5E02453837-01 3.9 Coexistence of the frequency bands Coexistence in the 2.4 band The use of the HMI device does not affect the communication with other devices or only negligibly so. This applies to the following communication networks: ●  WLAN When adding a WLAN participant, make sure that you observe the conditions described in the document "Wireless LAN in a PROFINET IO Environment". The conditions vary depending on the operating mode and the requirement for PNIO refresh times. See Guideline for the Use of Industrial Wireless LAN in a PROFINET IO Environment (http://support.automation.siemens.com/WW/view/en/31938420). ●  Standard RFID system according to ISO 15693 ●  Communication protocols that are used for office networks, smoke detectors, bar code scanners etc. in the 2.4 GHz range You need to plan the radio channels when operating such devices simultaneously in the 2.4 GHz band – see "SCALANCE W-700" configuration manual (http://support.automation.siemens.com/WW/view/en/32816761)". Otherwise sufficient bandwidth for communications cannot be guaranteed. ●  ZigBee devices Coexistence with other communication networks Moreover, coexistence is ensured for the following communication networks: ●  Coexistence in the 5 band Planning for the radio channels of all WLAN systems in use is required to ensure sufficient bandwidth for communication. ●  WirelessHART You need to plan for the radio channels for simultaneous operation of Industrial Wireless LAN systems and WirelessHART systems in the 2.4 GHz band. Avoid simultaneous use of overlapping frequency ranges. There is overlapping between Industrial Wireless LAN and WirelessHART – see "SCALANCE W-700" configuration manual (http://support.automation.siemens.com/WW/view/en/32816761), section 2.3. See also WLAN properties (Page 51) PRELIMINARY II 1.7.2010
 Planning the use  3.10 Planning information security Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  59 3.10 Planning information security Information security is a vital aspect in automation engineering particularly to ensure the availability and interference-free operation of industrial plants. To ensure communication and information security via WLAN for the HMI device, you need to protect the communication system from attack. Expect:  ●  Attacks from the outside To protect against external attacks, you must protect the WLAN in the same way you would protect office communication, namely with a firewall.  ●  Attacks from the inside Investigations have shown that the majority of attacks on information security are executed from inside the plant. To ensure information security, you need to take action for: –  Configuration and parameter settings Possible objectives of an attack are the project and the parameter settings of the HMI device. –  Productive operation data The productive data can be manipulated, for example by sending a series of false PROFIsafe message frames which prevent the plant from being switched off. Data transfer between HMI device and access point is protected by the AES encryption mechanism. Manipulation of productive data is prevented in this manner. Organizational measures The organizational measures to ensure information security are described in the following documents: ●  IEC 61784-3-3:2007 Functional safety field busses – Additional specifications for CPF 3 ●  PROFIsafe - Environmental Requirements Specify the organizational measures you must implement in accordance with your plant's requirements to achieve the highest possible information security for communication via WLAN. In doing so, take into consideration: ●  Configuration phase ●  Process control phase Check the interplay of the specified measures. PRELIMINARY II 1.7.2010
Planning the use   3.10 Planning information security  Wireless Teach Pendant F IWLAN V2 60 Operating Instructions, 08/2010, A5E02453837-01 Checklist  Perform the following tasks for application planning and confirm the implementation of each step in the following checklist. The tasks only conditionally required for PROFIsafe compliance are marked italic  in the checklist. ●  Access point  Task  Additional information  Check Select the installation site and antenna characteristics of the access point in such a manner that only the desired area is supplied with wireless capacity. In this regard note that wireless waves spread out horizontally as well as vertically.  Access point operating instructions "SINEMA E" planning program (http://www.siemens.com/sinema)  Install the access points at locations secured against attack, for example, in suspended ceilings. This can prevent manipulation at the access point or at the Ethernet connection to the LAN. –   Always use cable connections to configure access points. –   Change the administrative password set.  "SCALANCE W-700" configuration manual (http://support.automation.siemens.com/WW/view/en/32816761)  Hidden SSID Configure the access point so that the SSID of the radio cell remains hidden.  "SCALANCE W-700" configuration manual (http://support.automation.siemens.com/WW/view/en/32816761)  Change the SSID setting.  Entering and deleting a password (Page 114)  PRELIMINARY II 1.7.2010
 Planning the use  3.10 Planning information security Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  61 ●  Communication network  Task  Additional information  Check Examine the application environment with a spectrum analyzer and via WLAN measurement programs for possible radio interference.  If you detect sources of interference, specify the appropriate remedial measures. Log the results.–   Only operate the communication network in the infrastructure mode. System manual "Basics on Setting up an Industrial Wireless LAN" (http://support.automation.siemens.com/WW/view/en/9975764), "Network architecture" section  Isolate the automation networks from all other networks. Use routers and firewalls or VPNs at points where connections to these networks are needed. Limit the communication between the networks to the absolute minimum required. Operating Instructions "SCALANCE X-400" (http://support.automation.siemens.com/WW/view/en/19625216) Operating Instructions "SCALANCE S and SOFTNET Security Client" (http://support.automation.siemens.com/WW/view/en/21719299)  Prevent unauthorized participation in the wireless communication using authentication mechanisms.  "SCALANCE W-700" configuration manual (http://support.automation.siemens.com/WW/view/en/32816761)  ●  HMI device  Task  Additional information  Check Use a password to protect the Control Panel and Taskbar of the HMI device against unauthorized access. Section "Entering and deleting a password (Page 114)"  Enable the data channel used to transfer the project to the HMI device only during the transfer of the project. Section "Programming the data channel (Page 142)"  Enable encryption for data transmission in the WLAN configuration. Change the default password for accessing the WLAN configuration in the Web Based management. Section "Configuring the WLAN connection (Page 116)"  PRELIMINARY II 1.7.2010
Planning the use   3.10 Planning information security  Wireless Teach Pendant F IWLAN V2 62 Operating Instructions, 08/2010, A5E02453837-01 ●  F-CPU and safety program  Task  Additional information  Check Use passwords to protect access to the F CPU and safety program. Programming and operation manual "S7 Distributed Safety - Configuring and Programming" (http://support.automation.siemens.com/WW/view/en/22099875), section "Protection against attack"  ●  WinCC flexible ES  Task  Additional information  Check Protect WinCC flexible Es with general IT technologies. Examples:  Protect the PC where the ES is installed on the operating system level with a password.  Use a suitable encryption program to encrypt files, folders, and partitions.  Assign the access right for a drive only to a specific group of people.  Encrypt the data with mechanisms provided by MS Windows. –   Use a password to protect the "Effective range name" object. WinCC flexible Information System   You can find addition information on the topic of data security in the following publications: ●  System manual "Fundamentals - Industrial Wireless LAN", section "Information security of wireless communication in accordance with IEEE 802.11". ●  Brochure "Wireless Communication Systems and their Security Aspects" published by the German Federal Agency for Security in Information Technology PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  63 Mounting and connection 44.1 Check the scope of delivery Check the scope of delivery for completeness and visible signs of transport damage.   NOTICE  Do not use damaged parts If you use defective parts from the scope of delivery, you may experience malfunctions. If you find defective parts in the scope of delivery, contact your Siemens partner. Only install undamaged parts.   4.2 Installing an RFID tag Requirement ●  1 RFID tag ●  1 fixing pocket ●  2 M4 cylinder head screws with nuts, if required ●  An installation location has been selected for the RFID tag as described in the section, "Planning an installation location for RFID tags (Page 54)". If installing on a metallic base: ●  1 spacer ●  4 M4 cylinder head screws with nuts, if required    Note The mounting brackets on both sides of the spacer permit fixation with cable ties.  0RXQWLQJKROH0RXQWLQJKROH%UDFNHW PRELIMINARY II 1.7.2010
Mounting and connection   4.3 Installing the docking station  Wireless Teach Pendant F IWLAN V2 64 Operating Instructions, 08/2010, A5E02453837-01 Procedure- with a metallic installation location  Proceed as follows: 1. Position the spacer on the installation location. 2. Mark the fastening holes with a marking-off tool. 3. Drill two through-holes or two threaded holes, M4. 4. Mount the spacer. 5. Bend the tabs on the fixing pocket to the rear at right angles. 6. Slide the RFID tag into the fixing pocket. 7. Slide the tabs of the fixing pocket into the spacer. The tabs snap into place and are secured by studs. Procedure – with a non-metallic installation location Proceed as follows: 1. Position the fixing pocket on the installation location. 2. Mark the fastening holes with a marking-off tool. 3. Drill two through-holes or two threaded holes, M4. 4. Fasten the fixing pocket. 5. Slide the RFID tag into the fixing pocket. 4.3 Installing the docking station Requirement ●  2 M5 cylinder head screws with nuts, if required Read the section "Planning the installation location and clearance of the docking station (Page 56)". Procedure  Proceed as follows: 1. Place the docking station on the mounting surface. 2. Mark the fastening holes with a marking-off tool. 3. Drill two through holes or two threaded holes M5. 4. Mount the docking station. PRELIMINARY II 1.7.2010
 Mounting and connection   4.4 Connecting the docking station and charger Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  65 4.4 Connecting the docking station and charger The power supply provides electricity to the docking station and charger.  NOTICE  Use only approved power supplies If you use an unapproved power supply, damage may occur to the HMI device. Only use the power supply approved for the HMI device. Danger of overheating There is danger of overheating if you cover the power supply and thereby inhibit the air circulation. Do not cover the power supply unit.   Note Unplug the mains connector of the power supply to ensure complete electrical isolation. The power supply is designed for operation on grounded power supply networks (TN systems to VDE 0100, Part 300, or IEC 364-3). Operation is not authorized on ungrounded or impedance-grounded power networks (IT systems).  Read the section "ESD guideline (Page 251)". Requirement ●  The docking station is installed or the charger is ready for operation. ●  The power supply is ready. Procedure – disconnection  Proceed as follows: 1. Store the power supply unit in a safe place. 2. Insert the plug of the 24 V power cable into the socket of the docking station or charger. 3. Connect the power supply unit to the mains. Procedure – disconnection Proceed as follows: 1. Pull the plug of the 24 V power cable out of the socket of the docking station or out of the charger. 2. Disconnect the power supply unit from the mains. See also Power supply unit (Page 19) PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 66 Operating Instructions, 08/2010, A5E02453837-01 4.5 Connecting the HMI device 4.5.1 Safety instructions  CAUTION  Use only approved devices Non-approved devices may cause malfunctions. Only operate the HMI device with approved devices as specified in the section, "Overview (Page 13)". Malfunction possible If the HMI device is switched on and lying on its front, any one of the operator controls can trigger a malfunction. Switch off the HMI device whenever possible. Damage to the HMI device by foreign objects and liquids Damage may occur to the HMI device if it is opened by unauthorized personnel. Foreign bodies or liquids must not penetrate the interior of the HMI device or come into contact with the printed circuit board. The connection and battery compartments therefore may only be opened by professional personnel for servicing.  NOTICE  Do not exceed the bridging time If the main rechargeable battery is removed, the HMI device supplied by the rechargeable buffer battery. The maximum bridging time is 20 seconds. If you exceed the bridging time, the HMI device may switch off automatically. This triggers a shutdown or rampdown of an integrated HMI device. Do not exceed the bridging time! Opening the connection or battery compartment The HMI device does not meet degree of protection IP65 when the connection or battery compartment is open. Do not open the connection or battery compartment if dust or moisture can enter the device. Close an open compartment completely.  See also ESD guideline (Page 251) PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  67 4.5.2 Opening and closing the terminal compartment The connection compartment may not be opened while the HMI device is in operation. Opening the connection compartment does not interrupt the power supply to the HMI device.  Note Read the section "Safety instructions (Page 66)".  Requirement  ●  Screwdriver, size 6.5 x 150 Procedure – opening the connection compartment Proceed as follows: 1. Lay the HMI device on its front side. 2. Loosen the screws. &RYHUIODS6FUHZ 3. Lift the cover. The connection compartment opens. Procedure – closing the connection compartment Proceed as follows: 1. Close the cover of the connection compartment. When closing the connection compartment, ensure that: –  The seal is present and properly positioned. –  The connection cables of the rechargeable buffer battery are not pinched. 2. Tighten the screws. The connection compartment is open. PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 68 Operating Instructions, 08/2010, A5E02453837-01 4.5.3 Ports and reset button The following figure shows the interfaces and reset button of the HMI device.   ①  USB port with cover ②  Rechargeable buffer battery ③  Memory card slot ④  Plug and socket for the rechargeable buffer battery ⑤  Reset button ⑥  Contact for the power supply ⑦  RJ45 socket for LAN   Note The RJ45 interface is only suitable for commissioning. If you want to use the RJ45 port, the connection compartment must be open. The IP65 degree of protection is no longer met for the Wireless Teach Pendant F IWLAN when the connection compartment is open. Do not open the connection compartment if dust or water could enter the device.  All unsaved data will be lost when you press the reset button. Press the reset button only when the HMI device is no longer working properly and no longer responds to input. PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  69 4.5.4 Inserting a memory card Only use memory cards approved for use with the HMI device, see section Accessories (Page 16). The following can be saved to the memory card of the HMI device: ●  Operating system ●  Applications ●  Data The memory card can be inserted and removed during operation. Do not remove the memory card while data is being accessed, for example during data backup or recipe transfer. Requirement  ●  The connection compartment opens. Procedure – inserting a memory card    Note Read sections "Safety instructions (Page 66)" and "Opening and closing the terminal compartment (Page 67)". Proceed as follows: 1. Open the connection compartment. 2. Insert the memory card into the slot. 6ORW An arrow on the memory card indicates the front side and the direction of insertion. When the memory card is correctly inserted into the slot, it stands approx. 3 mm proud of the slot. 3. Close the connection compartment or proceed with the following tasks. PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 70 Operating Instructions, 08/2010, A5E02453837-01 Procedure – using a memory card for the first time    Note The first time you use a memory card, the HMI device will prompt you to format it. All data is lost on the memory card during formatting. Back up existing data, if necessary, before you use the memory card in the HMI device.  Proceed as follows: 1. Cancel the formatting procedure by pressing "ESC". 2. Remove the memory card from the slot. 3. Back up data that are still needed. 4. Insert the memory card into the slot. 5. Format the memory card. Procedure – removing a memory card  Proceed as follows: 1. Pull the memory card out of the slot. 2. Store the memory card in a safe place. 3. Close the connection compartment. PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  71 4.5.5 Connecting the rechargeable buffer battery Before you begin operation of the HMI device, you need to connect the rechargeable buffer battery. You can only replace the main rechargeable battery without switching off the HMI device when the rechargeable buffer battery is connected. Procedure   Note Read the following sections:  "Opening and closing the terminal compartment (Page 67)"  "Safety instructions (Page 72)".  Proceed as follows: 1. Open the connection compartment. 2. Plug the connector if the cable into the socket on the printed circuit board. 5HFKDUJHDEOHEXIIHUEDWWHU\&RQQHFWLQJFDEOH3OXJDQGVRFNHW3ULQWHGFLUFXLWERDUG 3. Position the cable so that it is not pinched when you close the connection compartment. 4. Close the connection compartment. PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 72 Operating Instructions, 08/2010, A5E02453837-01 4.5.6 Replacing and charging the main rechargeable battery 4.5.6.1 Safety instructions CAUTION  Charging and discharging the rechargeable battery There is a risk of fire and, in extreme cases, explosion in the following situations!  Incorrect charging and discharging of the rechargeable battery  Reverse polarity  Short-circuit Only charge the rechargeable battery in the HMI device or in a charger approved for the HMI device. Contact with battery fluid If used incorrectly, fluid can leak from the battery.  Avoid contact with the battery fluid. If battery fluid comes in contact with skin, rinse it off with water. If battery fluid comes into contact with the eyes, seek medical advice. NOTICE  Use only approved batteries If you use non-approved batteries, malfunctions may occur as a result. Only use batteries that are approved for the HMI device. Fully charge the main rechargeable battery before first use If you attempt to use a main rechargeable battery in the HMI device in its factory state, the HMI device will not start. Fully charge the main rechargeable battery before inserting it in the HMI device.   Note The following applies to lithium-ion rechargeable batteries:  Do not crush  Do not heat or burn  Do not short-circuit  Do not disassemble  Do not immerse in liquids – the rechargeable battery may rupture or burst  Store unused rechargeable batteries away from the following items which can cause the contacts to be bridged. These include: –  Paper clips –  Coins –  Keys –  Nails –  Screws or other small metal objects PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  73 4.5.6.2 Replacing the main rechargeable battery You can replace the main rechargeable battery during operation. The rechargeable buffer battery supplies the power while the main rechargeable battery is being replaced. The maximum bridging time is 20 seconds. If you exceed the buffer time, the HMI device will switch off. During the bridging time, the following features are disabled:  ●  Display backlighting ●  All LEDs except for "SAFE" and "RNG" ●  The illuminated pushbuttons ●  The USB ports    Note Read the section "Safety instructions (Page 72)". If the capacity of a rechargeable battery drops to 50 percent of the original capacity, use a new rechargeable battery. A new rechargeable battery is needed after 500 full charge cycles. Example of a full charge cycle: The charge level of a rechargeable battery decreases from 100 percent to 80 percent. The rechargeable battery is charged again in this state and then reaches 100 percent. Discharging to 80 percent and recharging to 100% adds up to a full charge cycle. Keep main rechargeable batteries in stock.  PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 74 Operating Instructions, 08/2010, A5E02453837-01 Procedure  Proceed as follows: 1. Lay the HMI device on its front side.  CAUTION   Potential malfunction when HMI device switched on If the HMI device is switched on and lying on its front, any one of the operator controls can trigger a malfunction. Make sure that no operator control can be triggered when the HMI device is laid down.  2. Slide the compartment cover in the direction of the arrow until it catches. If you are using the HMI device for the first time, there is no main rechargeable battery in the battery compartment. %DWWHU\FRPSDUWPHQW0DLQUHFKDUJHDEOHEDWWHU\5LEERQ&RPSDUWPHQWFRYHU 3. Remove the main rechargeable battery by pulling on the ribbon. 4. Insert a charged main rechargeable battery. 5. Close the compartment cover fully. PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  75 4.5.6.3 Charging the main rechargeable battery The main rechargeable battery is not fully charged when delivered. The main rechargeable battery is charged: ●  In the HMI device while it is sitting in the docking station. ●  In the charger    Note Read the section "Safety instructions (Page 72)".  Before charging the main rechargeable battery, read the documentation that accompanies the charger. Requirement The following devices are available: ●  Charger° (Page 18) ●  Power supply unit (Page 19) Procedure – Connecting a charger and charging the main rechargeable battery    Note When charging a rechargeable battery, the ambient temperature or battery temperature should not exceed 40° C. The higher the temperature, the longer it will take for the rechargeable battery to fully charge.  Select a location for the charger with a cool ambient temperature. Let the rechargeable battery cool before charging it. Keep to the permitted ambient conditions. The main rechargeable battery can be place in the charger before or after connecting the power supply unit.  Proceed as follows: 1. Store the power supply unit in a safe place. 2. Insert the plug of the power cable into the socket of the charger. 3. Connect the charger to the mains. The "POWER" LED lights up. 4. Place the rechargeable battery into the charger. The rechargeable battery is fully charged once all five LEDs are lit. See section "Showing the battery charge (Page 76)". PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 76 Operating Instructions, 08/2010, A5E02453837-01 Procedure – Disconnecting the charger Proceed as follows: 1. Pull the plug of the power cable out of the charger's socket. The "POWER" LED goes out. 2. Disconnect the power supply from the mains. 4.5.6.4 Showing the battery charge The main rechargeable battery features an LED array. The respective LEDs indicate the battery charge. .H\/('DUUD\FRQVLVWLQJRIILYH/('V Requirement  ●  The main rechargeable battery is removed from the HMI device. Procedure  Proceed as follows: 1. Press the button. The LED lights when the button is released after approx. 5 seconds. The number of illuminated LEDs indicates the charge status.   Number of LEDs  Flashes for  Lights for 1  0 to 19 % of the charge capacity  20 to 39 % of the charge capacity 2  -  40 to 59 % of the charge capacity 3  -  60 to 79 % of the charge capacity 4  -  80 to 96 % of the charge capacity 5  -  97 to 100 % of the charge capacity If all the LEDs light up, the main rechargeable battery is fully charged.   Note This applies to rechargeable batteries that are stored – read the section "Maintenance and care (Page 237)".  PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  77 4.5.7 Connecting the PLC Only use approved components to connect a SIMATIC S7 PLC. You can find more information on this on the Internet in Industry Mall (http://mall.automation.siemens.com). Configuration graphic  The following figure shows the connection between the PLC and the HMI device. (WKHUQHW6,0$7,&6)6,0$7,&6 See also System manual "Basics on Setting up an Industrial Wireless LAN" (http://support.automation.siemens.com/WW/view/en/9975764) PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 78 Operating Instructions, 08/2010, A5E02453837-01 4.5.8 Connecting the configuration PC You have the following options for connecting a configuration PC to the HMI device: ●  Connection via WLAN ●  Connection via LAN and RJ45 interface ●  Connection via USB Configuration graphic  The following figure illustrates the options for connection between the HMI device and the configuration PC. (WKHUQHW(WKHUQHW86% PRELIMINARY II 1.7.2010
 Mounting and connection  4.5 Connecting the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  79  NOTICE  Adhere to the USB connection sequence  You will not be able to transfer a project to the HMI device if you do not adhere to the connection sequence. Observe the following sequence when connecting by USB: 1. HMI device 2. PC USB host-to-host cable  You will not be able to transfer a project to the HMI device if you use the driver for the USB host-to-host cable. Use only the driver for the USB host-to-host cable that is included in the WinCC flexible package.   Note Point-to-point connection Use a cross cable for a point-to-point connection. The HMI device and the PC can also be subscribers in a local area network. Connection via WLAN In its factory state, the WLAN interface of the HMI device is disabled. Before you access the HMI device from the configuration PC via WiFi, you need to appropriately configure the access point and HMI device in infrastructure mode. An ad hoc wireless network is not possible.  Restoring the factory settings  To update the operating system and reset the factory settings, you need to connect the HMI device to the configuration PC via the RJ45 port. Connect a configuration PC directly to the HMI device only as long as it is necessary. You can find additional information in the "Restoring factory settings (Page 194)" section. PRELIMINARY II 1.7.2010
Mounting and connection   4.5 Connecting the HMI device  Wireless Teach Pendant F IWLAN V2 80 Operating Instructions, 08/2010, A5E02453837-01 4.5.9 Connecting a USB device You can connect the following devices to the USB port of the HMI device:  ●  External mouse ●  External keyboard ●  USB memory stick Only connect industrial devices. Note when connecting  NOTICE  USB interface only suitable for commissioning Use the USB interface for commissioning and maintenance only. The cable length of the connected USB devices may not exceed 3 meters. IP65 protection with a USB device not guaranteed If a USB device is connected to one of the USB ports, the HMI device does not comply with the IP65 degree of protection. Do not connect a USB device if dust or moisture can enter the device. Devices with a separate power supply Self-powered devices cause a malfunctions in the HMI device. A PC or configuration PC is an exception. Only connect a configuration PC or PC to the USB port. Malfunction A USB device that places too much power consumption load on the USB port can damage the HMI device. Be aware of the maximum power load placed on the USB port. Access to USB port  The USB port is disabled while the main rechargeable battery is being replaced. You cannot save data to a USB memory stick, for example, while the main rechargeable battery is being replaced. Ensure no one tries to access the USB port while the main rechargeable battery is being replaced.   Note Devices without a separate power supply connected to the USB port increase the power load. This will reduce the service life of the HMI device.   See also Specifications (Page 244) PRELIMINARY II 1.7.2010
 Mounting and connection   4.6 Switching on and testing the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  81 4.6 Switching on and testing the HMI device When the HMI device is initially put into operation, there is no project. Ethernet is set as the data transfer channel. Requirement ●  A charged main rechargeable battery is inserted in the HMI device. Procedure  Proceed as follows: 1. Briefly press the "ON/OFF" button. The "PWR" LED lights up – see section "LED display (Page 85)". The display then lights. A progress bar is displayed during startup. The loader is displayed once the operating system has started.  If a charged main rechargeable battery is inserted, the "BAT" LED lights up. The HMI device automatically switches to "Transfer" mode if the following two requirements are met: –  No project is loaded on the device. –  At least one data channel has been configured. The following dialog appears:  2. Press the "Cancel" button. The transfer is canceled. The Loader appears. PRELIMINARY II 1.7.2010
Mounting and connection   4.7 Switching off the HMI device  Wireless Teach Pendant F IWLAN V2 82 Operating Instructions, 08/2010, A5E02453837-01 Result  The HMI device is ready for operation when the loader displays one of the following dialogs: ●  "Transfer" dialog ●  "Testing enabling button" dialog 4.7 Switching off the HMI device The following procedure applies to an HMI device on which there is no project. The way the device is switched off therefore differs from that of an integrated HMI device. Procedure  Proceed as follows:  1. Press the "ON/OFF" button on the HMI device at least 4 seconds. The HMI device switches off. See also Switch-off behavior (Page 208) PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  83 Operator controls and displays 55.1 Overview The standard input unit on the HMI device is the touch screen. All operator controls required for operation appear in one or more HMI screens on the display after the project starts.  NOTICE  Damage to the touch screen Never touch the touch screen with a pointed or sharp object. Avoid applying sudden pressure to the touch screen with a hard object. Both these will substantially reduce the service life of the touch screen and can even lead to total failure. Always operate the touch screen of the HMI device with your fingers or with a touch pen.  Membrane keyboard  The following figure shows the membrane keyboard of the Wireless Teach Pendant F IWLAN.  ①  Membrane keyboard – six buttons simultaneously enabled ②  Membrane keyboard for robot control ③  Key  "ON/OFF" PRELIMINARY II 1.7.2010
Operator controls and displays   5.1 Overview  Wireless Teach Pendant F IWLAN V2 84 Operating Instructions, 08/2010, A5E02453837-01  NOTICE  Damage to the membrane keyboard Do not touch the keys with a pointed or sharp object. Avoid applying sudden pressure to the keys with a hard object. Both of these will substantially reduce the service life of the membrane keyboard and can even lead to total failure. Only use your fingers to operate the HMI device buttons.  The functions assigned to the keys of the membrane keyboard are defined during configuration. Outside of the project, the keys of the membrane keyboard have no function. Displays and other operator controls ●  LED display ●  EMERGENCY STOP button ●  Enabling button ●  Rotary switch ●  Illuminated pushbutton PRELIMINARY II 1.7.2010
 Operator controls and displays  5.2 LED display Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  85 5.2 LED display An LED display consisting of five LEDs is located on the front of the HMI device. The LED display shows the operating states for the HMI device and the communication. /('GLVSOD\/('IRUURERWDSSOLFDWLRQ Meaning of LEDs  The LED display is activated when the HMI device is switched on.  LED  Color  Function  LED signals SAFE  Yellow  PROFIsafe communication The "SAFE" LED lights up when the HMI device is integrated in the safety program of the F CPU. Requirement – PROFIsafe communication has been established. If the "SAFE" LED lights up, the EMERGENCY STOP button is enabled.  PWR  Green  Power  The "PWR" LED only lights up or flashes when the HMI device is switched on. The "PWR" LED lights up under the following circumstances:   The main rechargeable battery is inserted and charged.  The HMI device is in the docking station. The "PWR" LED flashes when the HMI device is in the "POWER SAVE 2" operating mode. COM  Green  Communication The "COM" LED is off if no WLAN is available. The "COM" LED flashes when the HMI device attempts to establish a connection to the WLAN. The "COM" LED lights when there is a connection between the HMI device and WLAN.  RNG  Green  Effective range  The "RNG" LED lights when the HMI device is logged on to a machine. If a communication error occurs after the HMI device has logged on to a machine, the "RNG" lights up until PROFIsafe communication is reestablished and the communication error has been acknowledged. The "RNG" LED is off when the HMI device is logged off a machine.  Refer to the plant documentation for additional information on the meaning of the LEDs. PRELIMINARY II 1.7.2010
Operator controls and displays   5.2 LED display  Wireless Teach Pendant F IWLAN V2 86 Operating Instructions, 08/2010, A5E02453837-01 Meaning of the "BAT" LED  The "BAT" LED signals the following states depending on the type of power supply:  BAT LED Power supply ① ② ③ ④ ⑤ ⑥ Rechargeable battery operation, HMI device on          –  Rechargeable battery operation, HMI device off             Docking station, HMI device on or off               ① Charge at ≤6% capacity ② Charge at > 6% capacity ③ Maximum charge ④ Rechargeable battery not in the HMI device ⑤ Rechargeable battery temperature too high ⑥ Possible error:  Short circuit, discharge current > 8.0 A  Overload, discharge current > 4.0 A  Overload, charge current > 2.8 A  Charging error, cell voltage > 4.3 V  Charging error, cell voltage < 3.0 V Note the following: ●  An error event always has priority. If an error occurs, the "BAT" LED signals according to column ⑥. ●  If the battery is not fully charged, the "BAT" LED signals according to column ⑤. ●  If the main rechargeable battery is fully charged, the "BAT" LED signals according to column ③. PRELIMINARY II 1.7.2010
 Operator controls and displays   5.3 Power management Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  87 5.3 Power management The HMI device is equipped with a power management function. If you do not operate the HMI device within a configured time period, power management will switch the HMI device to power saving mode. This extends the operating period of the HMI device until the next time the main rechargeable battery is replaced or the next time it is charged. Operating modes in power management  Power management has two operating modes: ●  "Power Save 1" –  Reduces the brightness of the touch screen. –  The EMERGENCY STOP button remains available. –  As long as the HMI device is logged on, the enabling button remains enabled.    Note When you place the HMI device in the docking station, it will automatically assume the operating state "Power Save 1" after 2 minutes. If a time period of less than 2 minutes has been specified for activation of "Power Save 1" mode in the WinCC flexible project, then this time period will be applied.  ●  "Power Save 2" –  The touch screen is switched off. –  Other power save measures are activated. The online help for WinCC flexible describes how to configure power management. –  The EMERGENCY STOP button remains available. –  The rotary switch remains available. ●  "Power Save 1" corresponds to the "Reduce brightness" setting. ●  "Power Save 2" corresponds to the "Switch off screen" setting.    Note When the HMI device is logged on to a machine, "Power Save 2" operating mode is not available.  PRELIMINARY II 1.7.2010
Operator controls and displays   5.4 Safety-related operator controls  Wireless Teach Pendant F IWLAN V2 88 Operating Instructions, 08/2010, A5E02453837-01 Power management for the HMI device provides the following operating modes:  Operating mode LED  Action  Follow-up operating mode OFF  "PWR" is off. "BAT" is off. Briefly press Taste "ON/OFF"  ON Automatically, if no actions are performed within a configured time period. "Power Save 1" Briefly press Taste "ON/OFF"  "Power Save 2" ON  "PWR" lights up. Press Taste "ON/OFF" for at least 4 seconds. OFF Operation on the touch screen  ON Briefly press Taste "ON/OFF"  "Power Save 2" Automatically, after a configured time interval if no operations are carried out "Power Save 2" "Power Save 1"  "PWR" lights up. The brightness of the touch screen is reduced. Press Taste "ON/OFF" for at least 4 seconds. OFF Briefly press Taste "ON/OFF"  ON "Power Save 2"  "PWR" flashes. The touch screen is switched off.  Briefly press Taste "ON/OFF" and then press it for at least 4 seconds. OFF See also Setting the screen saver (Page 127) 5.4 Safety-related operator controls 5.4.1 EMERGENCY STOP button The EMERGENCY STOP button is designed with 2-channels and enables an EMERGENCY STOP of the plant unit with which safety-related communication is taking place. The EMERGENCY STOP button satisfies the requirements specified in DIN IEC 60947-5-5,1997 Annex K. You can find additional information in the section "Safety functions of the EMERGENCY STOP button (Page 41)". (PHUJHQF\VWRSEXWWRQ Due to its position, the EMERGENCY STOP button is equally accessible for both left-handed and right-handed persons. PRELIMINARY II 1.7.2010
 Operator controls and displays  5.4 Safety-related operator controls Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  89 Storing a non-integrated HMI device  WARNING  EMERGENCY STOP button out of service when HMI device is removed If the HMI device is not integrated in the safety program of the F-CPU, the EMERGENCY STOP button will be out of service. To avoid confusion between HMI devices with enabled and disabled EMERGENCY STOP buttons during an emergency, only one integrated HMI device should be freely accessible. If an HMI device is not integrated and not in use, store the HMI device in a location with protected access.  Requirement ●  The EMERGENCY STOP button is evaluated under the condition that the HMI device is integrated in the safety program of the F-CPU. See section "Safety-related configuration (Page 161)". Procedure – Operating the EMERGENCY STOP button   WARNING  Function the EMERGENCY STOP button The EMERGENCY STOP button has no effect if the HMI device is without power or removed from the safety program. Operate the HMI device in mobile mode using the main rechargeable battery or in stationary mode in the docking station and integrate it in safe-related communication.  NOTICE  Unintentional triggering of the EMERGENCY STOP button The EMERGENCY STOP button can be triggered unintentionally, thereby bring the plant to a standstill in the following cases:  When the HMI device is dropped.  When the HMI device is laid on its front. Handle the HMI device with care!  Proceed as follows: 1. Press the EMERGENCY STOP button fully if a dangerous situation develops. The EMERGENCY STOP button engages in the EMERGENCY STOP position. The associated plant unit is stopped. PRELIMINARY II 1.7.2010
Operator controls and displays   5.4 Safety-related operator controls  Wireless Teach Pendant F IWLAN V2 90 Operating Instructions, 08/2010, A5E02453837-01 Procedure – Releasing the EMERGENCY STOP button   WARNING  EMERGENCY STOP button released If you have pressed the EMERGENCY STOP button and thereby brought the plant unit to a standstill, you should only release the EMERGENCY STOP button under the following conditions:  The reasons for the EMERGENCY STOP have been eliminated.  A safe restart is possible.  The restart should not be performed by releasing the EMERGENCY STOP button. The project should force the operator to perform an action for restarting independent of the EMERGENCY STOP button. The safety program must specify that no automatic restart of the plant is possible simply by releasing the EMERGENCY STOP button.  Proceed as follows: 1. Turn the EMERGENCY STOP button clockwise to its original position. The EMERGENCY STOP button is released. 5.4.2 Enabling button The enabling mechanism consists of two enabling buttons which are installed on both sides of the HMI device. You can find additional information in the "Safety functions of the enabling mechanism (Page 42)" section. The enabling button is required to confirm axis movements, for example. (QDEOLQJEXWWRQ6DIHW\EDUV PRELIMINARY II 1.7.2010
 Operator controls and displays  5.4 Safety-related operator controls Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  91 The enabling button has three switch settings: ●  Neutral position The enabling button is not pressed. ●  Enable The enabling button is pressed to a middle switch position. The switch position has a noticeable pressure point. This switch position is used to confirm an entry, for example. ●  Panic The "Panic" switch position is reached as soon as one of the two enabling buttons is fully pressed. To do this, the pressure point of the "Enable" switching position must be overcome. An audible switching noise is then heard. The switch position of the other enabling button is unimportant in this case. The "Panic" switch position has the same effect as releasing the enabling button. In both switch positions, the enable is revoked. Requirement  ●  The enabling button is evaluated under the condition that the HMI device is integrated in the safety program of the F-CPU. See section "Safety-related configuration (Page 161)". Procedure  WARNING  Press the enabling button only as long as necessary Enabling is a conscious operator action. It is not permitted to continuously press the enabling button or to fasten it in place. Press the enabling button only until the operation you wish to enable is completed.   Note The enabling button only has an effect when the HMI device is logged on to a machine and the "RNG" LED on the HMI device is lit.   Proceed as follows: 1. Press at least one of the enabling button to reach the "Enable" position. The controller receives the same signal, regardless of whether one or both enabling buttons have been pressed.  NOTICE   Enabling button can tilt If you do not press the center of the enabling button, the enabling button may tilt. The switching process is delayed by this. A discrepancy error may occur – see section "Discrepancy error during enabling (Page 258)". Press the enabling button in the middle.  PRELIMINARY II 1.7.2010
Operator controls and displays   5.4 Safety-related operator controls  Wireless Teach Pendant F IWLAN V2 92 Operating Instructions, 08/2010, A5E02453837-01 Switch settings  The following figure shows the switching sequence for enable. (%(QDEOLQJEXWWRQ1HXWUDOSRVLWLRQ(%OHIW(%ULJKW(%OHIW(%ULJKW6ZLWFKVHWWLQJ(QDEOH1HXWUDOSRVLWLRQ[ \[\   The following figure shows the switching sequence during panic usage.  (%(QDEOLQJEXWWRQ1HXWUDOSRVLWLRQ(%OHIW(%ULJKW(%OHIW(%ULJKW6ZLWFKVHWWLQJ(QDEOH3DQLF 1HXWUDOSRVLWLRQ[ X[  X\\ If the operator presses the enabling button in the "Panic" switch position, the "Enable" switch position will not be evaluated when leaving the panic setting. A new enable can only be triggered by releasing the enabling button.   Note The HMI device analyzes the switch settings of the two enabling buttons in the form of an OR gate. The enabling button and membrane keyboard can be operated simultaneously.  5.4.3 Testing the function Perform an annual function test for the enabling button and EMERGENCY STOP button during commissioning. Procedure  Proceed as follows: 1. Switch on the HMI device. 2. Press both enabling buttons when the "Test Enabling Button" dialog is shown. 3. Press the EMERGENCY STOP button. PRELIMINARY II 1.7.2010
 Operator controls and displays  5.5 Operator controls Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  93 5.5 Operator controls 5.5.1 Operating the rotary switch The rotary switch has two positions. The function of the rotary switch is defined in the current project. Refer to the plant documentation for additional information on the function. 5RWDU\VZLWFK 5.5.2 Operating the illuminated push-button The function of the illuminated pushbutton is defined in the current project. Refer to the plant documentation for additional information on the function.  ,OOXPLQDWHGSXVKEXWWRQ 5.5.3 Evaluating operator controls 5.5.3.1 Overview The following information can be obtain between the Wireless Teach Pendant F IWLAN and PLC:  ●  Control state of the rotary switch ●  Control state of the illuminated pushbutton ●  Signal status of the LEDs There are two ways of transferring information: ●  Direct keys ●  System functions of WinCC flexible    Note The following sections are intended for the configuration engineer.  PRELIMINARY II 1.7.2010
Operator controls and displays   5.5 Operator controls  Wireless Teach Pendant F IWLAN V2 94 Operating Instructions, 08/2010, A5E02453837-01 5.5.3.2 Evaluating operator controls as direct keys You can configure the operator controls of the HMI device as direct keys. The control states of the following operator controls are then available directly in the IO area of the controller: ●  The control state of the rotary switch ●  The control state of the illuminated pushbuttons ●  The control state of illuminated pushbutton LED Byte assignment  The following figure shows the assignment of the keys (inputs) and LEDs (outputs) to the bytes in the PLC process image.  %XWWRQELWV /('ELWV%\WH77 6QQQQQQQQQQ                      S  Bit for rotary switch T1  Bit for illuminated pushbutton The bytes "n+6" to "n+9" contain the direct key bits for the touch buttons. Refer to your plant documentation for additional information. Bit assignment  The following tables show the bit assignment for the rotary switch and illuminated pushbutton: ●  Bit coding of rotary switch  State  S1  Automatic mode  0  Manual control  1 PRELIMINARY II 1.7.2010
 Operator controls and displays   5.6 Holding, operating and setting down the HMI device Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  95 ●  Bit coding of illuminated pushbutton  State  T1 Not pressed  0 Pressed  1 ●  Bit coding of illuminated pushbutton LEDs  State  T1 Off  0 On permanently  1 5.6 Holding, operating and setting down the HMI device Holding and operating the HMI device  The HMI device is equally easy to hold and operate for right-handers and left-handers because it is designed symmetrically. The free hand can be used to operate the operator controls on the front side.  Note Read the section "Safety-related operator controls (Page 88)". The neck strap provides support for holding of the Wireless Teach Pendant F IWLAN. Use the velcro closure on the neck strap to attach the strap to HMI device and adjust the length as necessary. The method of holding the HMI device shown in the following figure enables you to control movements in the plant to be monitored during servicing, for example.  The hand holding the HMI device can also be used to activate the enabling button. The enabling button is optimally accessible. In a dangerous situation, a safety shutdown is triggered in a panic reaction by releasing or fully pressing the enabling button. The EMERGENCY STOP button can also be quickly reached with your free hand. PRELIMINARY II 1.7.2010
Operator controls and displays   5.6 Holding, operating and setting down the HMI device  Wireless Teach Pendant F IWLAN V2 96 Operating Instructions, 08/2010, A5E02453837-01  NOTICE  Holding the HMI device If you do not carry the HMI device with the neck strap and hold it as shown, you cannot operate the EMERGENCY STOP button or enabling button quickly enough in a dangerous situation. Carry and hold the HMI device as shown. This especially applies to all hazardous movements that you control manually. You can then engage the EMERGENCY STOP button or enabling button as fast as possible in a dangerous situation.  Setting down the HMI device  A docking station is available for safe and stationary storage of the HMI device.  NOTICE  Pressing the EMERGENCY STOP button If the HMI device is placed in an unsuitable holder, the operability of the EMERGENCY STOP button will be impaired. Therefore, only use the docking station especially designed for storing the Wireless Teach Pendant F IWLAN.  The HMI device can be used as a stationary device when it is placed in the docking station. The following figure shows how the HMI device is placed in the docking station.  PRELIMINARY II 1.7.2010
 Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  97 Configuring the HMI device 66.1 Desktop and Loader Once the HMI device is switched on and booted, the display shows the desktop with the Loader.  ①  Desktop ②  Loader ③  Start menu  ④  Icon for screen keyboard ⑤  Icon for displaying IP information about the WLAN/LAN connection PRELIMINARY II 1.7.2010
Configuring the HMI device   6.1 Desktop and Loader  Wireless Teach Pendant F IWLAN V2 98 Operating Instructions, 08/2010, A5E02453837-01 Loader  The following figure shows the Loader.   The buttons on the Loader have the following function: ●  "Transfer" button – This switches the HMI device to "Transfer" mode. The transfer mode can only be activated when at least one data channel has been enabled for the transfer. ●  "Start" button – This starts the project on the HMI device. When you do not perform any operation, the project starts automatically based on the settings in the Control Panel after a delay time. ●  "Control Panel" button – This opens the Control Panel. You can make a variety of settings in the Control Panel, for example, the settings for the transfer. ●  "Taskbar" button – This opens the taskbar and the Windows CE Start menu.  The Loader will reappear when the project is closed on the HMI device. Password protection  You can protect the Control Panel and taskbar from unauthorized access. If password protection is configured, the "secure mode" message is displayed on the desktop. If the password is not entered, only the "Transfer" and "Start" buttons are operable. You can find additional information on Secure Mode in the section "Enabling and disabling SecureMode (Page 101)."  NOTICE  Keeping the password If the password is no longer available, you are forced to update the operating system to regain access to the Control Panel and the Windows CE taskbar. Backup password to protect it against loss. You can find additional information on updating the operating system in the section "Updating the operating system (Page 191)."  PRELIMINARY II 1.7.2010
 Configuring the HMI device  6.1 Desktop and Loader Wireless Teach Pendant F IWLAN V2 Operating Instructions, 08/2010, A5E02453837-01  99 Internet Explorer  Internet Explore for Windows CE is installed on the HMI device.    Note Internet Explorer for Windows CE and the Internet Explorer on a PC differ in terms of functionality. Internet Explorer for Windows CE has separate proxy settings that are independent of the settings in the Control Panel of the HMI device.  For more detailed information, refer to the Microsoft website.  PRELIMINARY II 1.7.2010
Configuring the HMI device   6.2 Operator input options  Wireless Teach Pendant F IWLAN V2 100 Operating Instructions, 08/2010, A5E02453837-01 Status bar When you click the icon in the status bar, the following dialog appears:  ①  Address type ②  IP address ③  Subnet mask ④  Button for details ⑤  Button to refresh the display The dialog contains information on the current WLAN or LAN connection 6.2 Operator input options The following operator control options are made available for the Windows CE interface and Control Panel:  ●  Touch screen The operator controls shown in the dialogs are touch-sensitive. Touch objects are operated in the same way as mechanical keys. You activate an operator control by pressing on it with your finger. To double-click them, touch an operator control twice in succession. ●  Membrane keyboard You can use the numeric area of the membrane keyboard to enter numeric values. ●  USB keyboard  You can operate the Windows CE interface and Control Panel with an external keyboard in the exact same way as you do with the screen keyboard of the HMI device. ●  USB mouse  You can operate the Windows CE interface and Control Panel with an external mouse in the exact same way as you do with the touch screen of the HMI device. PRELIMINARY II 1.7.2010

Navigation menu