Siemens RF340R01 Inductive Tag Reader User Manual SIMATIC RF300

Siemens AG Inductive Tag Reader SIMATIC RF300

User Manual IV

 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  209 System integration 8 The communication modules (interface modules) are links between the RFID components (reader and transponder) and the higher-level controllers (e.g. SIMATIC S7), or PCs or computers.  8.2 Introduction RF310R, RF340R, RF350R and RF380R readers are connected to the controller via the following interface/communication modules: ● ASM 452 ● ASM 456 ● ASM 473 ● ASM 475 ● RF170C ● RF180C ● RF182C ● 8xIQ-Sense Function blocks, interface modules/communication modules and readers  Function blocks are used for integration into the SIMATIC. Using these, the input parameters are transferred to the reader using the "init_run"(RESET) command. You can find more detailed information on the software parameterization in Product Information "FB 45 and FC 45 input parameters for RF300 and ISO transponders" (http://support.automation.siemens.com/WW/view/en/33315697) or the Function Manual FB 45 (http://support.automation.siemens.com/WW/view/en/21738808) from edition A3 onwards.
System integration   8.2 Introduction  SIMATIC RF300 210  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Interface modules/communication modules and function blocks The following table shows the most important features of the interface modules/communication modules, as well as the compatible function blocks. Table 8- 1  Overview of interface modules/communication modules ASM/ communication module Interfaces to the application (PLC) Interfaces to the reader Function blocks Reader connections Dimensions  (W x H x D) in mm Temperature range Degree of protection ASM 452  PROFIBUS DP-V1 2 x 8-pin socket, M12 FC 45  1  134 x 110 x 55  0 °C to +55 °C IP67 ASM 456  PROFIBUS DP-V1 2 x 8-pin socket, M12 FB 45 FC 55 FC 56 2 (parallel) *  60 x 210 x 54 or 79 0 °C to +55 °C IP67 ASM 473  PROFIBUS DP-V1 2 x 8-pin socket, M12 FC 45 FB 45 FC 55 1  87 x 110 x 55  0 °C to +55 °C IP67 ASM 475  S7-300 (central), ET200M (PROFIBUS) Via screw terminals in front connector FC 45 FB 45 FC 55 2  40 x 125 x 120  0 °C to +60 °C IP20 SIMATIC RF170C PROFIBUS DP-V1 PROFINET IO 2 x 8-pin socket, M12 FB 45 FC 55 2 (parallel) *  90 x 130 x 60  -25 °C to +55° C IP67 SIMATIC RF180C PROFINET IO  2 x 8-pin socket, M12 FB 45  2 (parallel) *  60 x 210 54  0 °C to +60° C IP67 SIMATIC RF182C PROFINET IO  2 x 8-pin socket, M12 __  2 (parallel) *  60 x 210 x 30  0 to +60 °C IP67 8xIQ-Sense  8xIQ-Sense  Via screw terminals in front connector FC 35  2 (parallel) *  40 x 125 x 120  0 °C to +60 °C IP20 *) If 2 readers are used on one ASM, the following restrictions apply:  The maximum operating temperature is 35 °C  The input voltage is 24 V ±10% Current consumption ≤ 425 mA per reader
 System integration  8.3 ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  211 8.3 ASM 452 8.3.1 Features Area of application The ASM 452 interface module is a MOBY module for operating MOBY and RF300 components with RS422 over PROFIBUS DP-V1 on ● Any computers and PCs ● Any PLCs When operating the interface module on a SIMATIC S7, function blocks are made available to the user.  Figure 8-1  Interface module ASM 452 The ASM 452 is the result of consistent development of the familiar ASM 450/451 interface modules. Optimal data throughput can be achieved even in large-scale PROFIBUS configurations thanks to the use of acyclic data traffic on PROFIBUS DP V1. The minimum cyclic data load of the ASM 452 on the PROFIBUS provides the user with the guarantee that other PROFIBUS nodes (e.g. DI/DO) can still be processed at great speed. The ASM 452 is an interface module for communication between PROFIBUS and the RF310R with RS422 interface. Through the ASM 452, the data on the RF300 transponder can be physically addressed ("Normal" addressing). In SIMATIC S7, FC 45 is available for this purpose. 8.3.2 Ordering data Table 8- 2  Ordering data for ASM 452 and accessories Product description  Order No. ASM 452 interface module for PROFIBUS DP-V1, 1x RF3xxR with RS422 interface, without connector for 24 V DC and PROFIBUS 6GT2002-0EB20 Accessories: Connector for PROFIBUS DP and 24 V supply  6ES7194-1AA00-0XA0 Connecting cable RF3xxR ↔ ASM 452
System integration   8.3 ASM 452  SIMATIC RF300 212  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Product description  Order No. Plug-in cable, pre-assembled, length: 2 m (standard length)  6GT2891-1CH20  Plug-in cable, pre-assembled, length: 5 m  6GT2891-1CH50 Opt. Cable connector without read/write device cable  (for cable lengths > 20 m) ASM 452 ↔ reader 6GT2090-0BC00 M12 blanking cap for unused RF310R connection (1 pack = 10 pieces) 3RX9802-0AA00 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 Replacement part: Connector plate; T functionality for PROFIBUS connection  6ES7194-1FC00-0XA0 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables.
 System integration  8.3 ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  213 8.3.3 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignments of ASM 452. 352),%86'36RFNHW;DQG;3LQDVVLJQPHQW 6LJQDO % UHG 3( 3( 6LJQDO $ JUHHQ / 06XSSO\YROWDJH/('VIRU5)DQG$605[' 5HDGHU DFWLYH ZLWK35((55 7UDQVSRQGHUSUHVHQWRUHUURU GLVSOD\35((55 IRUUHDGHU7KHWUDQVSRQGHUSUHVHQWGLVSOD\DOZD\VWDNHVSULRULW\7KHHUURULVRQO\LQGLFDWHGZKHQDWUDQVSRQGHULVQRWSUHVHQW7UDQVSRQGHUSUHVHQW7KH/('LVSHUPDQHQWO\21,IPRUHWKDQRQHWUDQVSRQGHULVLQWKHILHOGWKH  QXPEHURIWUDQVSRQGHUVLVLQGLFDWHGE\VKRUWLQWHUUXSWLRQV$IDXOWLVQRWRXWSXW(UURUGLVSOD\7KH/('LVSHUPDQHQWO\2))7KHODVWHUURUQXPEHULVLQGLFDWHGE\EULHIOLJKWSXOVHV5HDGHU 5HDGHULVVHOHFWHG5HDGHU 5HDGHULVVHOHFWHG2QO\UHDGHUFDQEHVHOHFWHG/('VIRU352),%86'36) 6\VWHP )DXOW%) %XV )DXOW21 /LJKWV XS ZKHQ WKHUH LV$60LVJHQHUDWHGE\WKH9VXSSO\YROWDJH9'& /LJKWVXSZKHQWKH9VXSSO\YROWDJHLVFRQQHFWHGWRWKH$601RWFRQQHFWHG3LQDVVLJQPHQWUHDGHU6RFNHW1RWDYDLODEOHIRU5);;;;$60; ;; ;;;;'&95['35((556/*5['6/*35((556)%)21 3( / 0 3( / 0; 5[' 7[' 7[' 5[' 3(; ;  9 9 '$ '(  9 9 '$ '( 3( 3( Figure 8-2  Pin assignment and LEDs of ASM 452
System integration   8.3 ASM 452  SIMATIC RF300 214  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.3.4 Configuration Configuration Hardware description  The ASM 452 has the same housing as the distributed I/O system ET 200X. General information on ASM 452 (e.g.: assembly, operation and wiring; general technical data) is available in the ET200X manual (Order No. 6ES7 198-8FA00-8AA0). Descriptions of accessories and network components can also be found in this manual. Configuration 352),%86'30DVWHUPRGXOHHJ6&389IRU$60bWRRWKHU352),%86EXVQRGHV352),%86HJ5)57DJ0'6$60 Figure 8-3  Configuration of ASM 452 PROFIBUS configuration  The ASM 452 is integrated into the hardware configuration by means of a GSD file. The ASM can then be configured using the HW Config of SIMATIC Manager or another PROFIBUS tool. A GSD file is provided for ASM 452 on the CD "RFID Systems Software & Documentation".
 System integration  8.3 ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  215 Operating mode of the ASM 452  The approved operating modes of ASM 452 are described in the GSD file. It is set using the hardware configuration tool (e.g. STEP 7 HW Config). Reader connection system  A reader always occupies two M12 connector sockets on the ASM 452. A pre-assembled cable therefore ensures easy connection of the reader (see figure below). The connecting cable is available in lengths of 2 m (standard) and 5 m. Extensions are possible up to 1000 m using connecting cables 6GT2891-… .  JUD\JUHHQZKLWHEURZQ\HOORZSLQNVKLHOG7ZRSLQ0FLUFXODUFRQQHFWRUV$60VLGH 5HDGHUVLGH0SLQ ;;;;;;; ; ;; Figure 8-4  Connecting cable (2 m) ASM 452/473 ↔ RF3xxR reader with RS422 (6GT2891-1CH20)  Cable installation  Signal  M12 (reader side)  Cable  X1 / Data  X2 24 V DC  1  Pink  -  1 TX -  2  Yellow  4  - GND  3  Gray  -  3 TX +  4  Green  1  - RX +  5  white  2  - RX -  6  brown  3  - -      -  - Shield  8 + terminal piece  Shield  5  5 Cable assignment ASM 452/473 ↔ RF3xxR reader with RS422 (6GT2891-1CH20) A reader cable connector with screw-type terminals is provided for users who want to individually pre-assemble their own cables (see figure below). Cables and reader cable connectors can be ordered from the MOBY catalog.
System integration   8.3 ASM 452  SIMATIC RF300 216  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 66VFUHZVIRURSHQLQJWKHFRQQHFWRU&RQQHFWRU0WR$60'HJUHHRISURWHFWLRQ,33*FDEOHJODQGPD[FDEOHGLDPHWHU PPRQO\VFUHZGRZQDIWHUDVVHPEOLQJWKHFRQQHFWRU$60FDEOH*7 &RQQHFWRUFRYHUUHPRYHG Figure 8-5  Cable connector ASM 452/473 ↔ RF3xx reader with RS422 (6GT2090-0BC00)  Pin assignment for ASM 452/473 cable connector  Connector pin  Connection to pin of the reader  Wire color 1  4 2  5 3  6 4  2 5  3 6  1  - S  8 + terminal piece Note data sheet provided by the manufacturer Pin 7 must not be connected. PROFIBUS cable with 24 V supply The ASM 452 can also be operated with the "green" PROFIBUS cable. It is important to ensure that a 24 V cable is connected from X12 to X13. The 24 V cable can be connected to pins 5 and 6 in plug X12. ; ;;; ;; Figure 8-6  PROFIBUS cable with 24 V supply
 System integration  8.3 ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  217 PROFIBUS address and terminating resistor  You must remove the connector plate from the ASM before you set the  PROFIBUS address or connect the terminating resistor. The connector plate covers the DIL switch. The position of the DIL switch in ASM is shown in the figure below with one setting example for each case. 212IIRQ  ([DPSOH352),%86DGGUHVVRQGHOLYHU\([DPSOH7HUPLQDWLQJUHVLVWRU2II $VGHOLYHUHGVWDWH6WDQGDUGPRGHXVH*6'ILOH6,(0%   Figure 8-7  Setting the PROFIBUS address/connecting the terminating resistor   Note  The PROFIBUS address in ASM 452 must always match the PROFIBUS address defined in the configuring software for this ASM.  To ensure that the terminating resistor functions correctly, you must always switch both DIL switches of the terminating resistor to "on" or "off".  8.3.5 Technical data Table 8- 3  Technical data for ASM 452 Serial interface to the user  PROFIBUS DP-V1 Procedure after connection  EN 50170 Vol. 2 PROFIBUS  PG 11 cable gland PROFIBUS and power supply connectors are not included in the scope of delivery Transmission rate  9600 baud to 12 Mbaud (automatic detection) Max. block length  2 words cyclic/240 bytes acyclic Serial interface to the RF3xxR   Connector  2 x M12 coupler plug Max. cable length  2 m = Standard length, 5 m, 10 m, 20 m and 50 m, (up to 1000 m on request) Readers that can be connected  1x RF3xxR with RS422 interface
System integration   8.3 ASM 452  SIMATIC RF300 218  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45 Transponder addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder Multi-tag capability  No S7 data structures via UDTs  Yes Power supply   Rated value  24 V DC Permissible range  20 V to 30 V DC Current consumption  Max. 180 mA; typ. 130 mA (without reader) Digital inputs  none Digital outputs  none Ambient temperature   Operation  0 °C to +55 °C Storage and transport  -40 °C to +70 °C Dimensions (W x H x D) in mm  134 x 110 x 55 (without bus connector) Fixing  4 M5 screws; for mounting on any plate or wall Weight, approx.  0,5 kg Degree of protection  IP67 MTBF (at 40 °C)  30 • 104 hours = 34 years 8.3.6 PROFIBUS Diagnosis The following table lists possible error indications with their meanings and provides remedies. Table 8- 4  LED indication for PROFIBUS diagnosis "BF" LED  "SF"LED  Cause of error  Error correction  ASM 452 is in start-up mode.  -  The connection to the DP master has failed.  ASM 452 not detecting a baud rate.  Check the PROFIBUS DP connection.  Check the DP master. ON  *  Bus interrupt  DP Master not functioning  Check all cables on your PROFIBUS DP network.  Check whether the connector plugs for PROFIBUS DP are securely plugged into the ASM 452.
 System integration  8.3 ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  219 "BF" LED  "SF"LED  Cause of error  Error correction flashes  on   The configuration data sent to the ASM 452 by the DP master do not match the configuration of the ASM 452.  Check the configuration of the ASM 452 (input/output, PROFIBUS address).  Correct GSD file being used?– SIEM80B6.GSD for ASM 452 Flashes  Off   ASM 452 has detected the baud rate, but is not being addressed by the DP Master.  ASM 452 has not been configured.  Check the PROFIBUS address set on the ASM 452 or in the configuration software.  Check the configuration of the ASM 452 (station type). on  Flashes   There is a hardware defect in the ASM 452.  Replace the ASM 452. 8.3.7 Dimension drawing The following figure shows the dimensional drawing of an ASM 452 with bus connectors. You must add the length of the PG cable gland and the radius of the cable used to the measured overall width and depth.   Figure 8-8  Dimensional drawing of ASM 452
System integration   8.4 ASM 456  SIMATIC RF300 220  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQGWUXQFDWHGVKLHOGEUDLGLQJ Figure 8-9  Length of stripped insulation for PROFIBUS cables 8.4 ASM 456 Configured with ASM 456 352),%86'30DVWHUPRGXOH6,0$7,&b69IRU$60DQGUHDGHUWRRWKHU352),%86EXVQRGHVHJ5)5HJ5)5352),%86$60b7DJV0'67DJV0'69WRRWKHU352),%86EXVQRGHV Figure 8-10  Configuration of ASM 456 For more detailed information, please refer to ASM 456 Operating Instructions (http://support.automation.siemens.com/WW/view/en/32629442).
 System integration  8.5 ASM 473 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  221 8.5 ASM 473 8.5.1 Features Field of application The ASM 473 interface module is an RF300 module for SIMATIC S7. It can be plugged into the ET 200X distributed I/O station and DESINA. ET 200X is operated by the user over PROFIBUS DP V1. An S7-300 or S7-400 with integrated PROFIBUS connection can be used as the controller.  ASM 473 supplements the SIMATIC S7 interface module ASM 475. The IP67 degree of protection means that it can be installed and operated in the process without the need for an additional protective housing. To operate the ASM 473, an ET 200X basic module BM 141/142 with the order number 6ES7141-1BF11-0XB0 or 6ES7142-1BD21-0XB0 or a BM 143 is required. The transponder data are accessed by means of physical addressing of the transponder. For operation in a SIMATIC S7, the function FC 45 is available. The hardware of the ASM 473 is configured with an object manager (OM) that is integrated in the SIMATIC Manager.  Figure 8-11  Interface module ASM 473 Other features: ● Up to 7 ASM 473 interface modules can be operated simultaneously in an ET 200X station. ● Any other I/O modules from the ET 200X spectrum can be operated with the ASM 473. 8.5.2 Ordering data Table 8- 5  Ordering data for ASM 473 and accessories Product description  Order No. Interface module ASM 473 1x RF3xxR reader with RS422 interface   6GT2002-0HA10 Accessories:
System integration   8.5 ASM 473  SIMATIC RF300 222  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Product description  Order No. Connecting cable ASM 473 ↔ Reader RF3xxR   Plug-in cable, pre-assembled, length 2 m (standard length)  6GT2891-1CH20 Plug-in cable, pre-assembled, length 5 m  6GT2891-1CH50 Opt. Cable connector without reader cable  (for cable lengths > 20 m) ASM 473 ↔ Reader 6GT2090-0BC00 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation"
 System integration  8.5 ASM 473 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  223 8.5.3 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignment for the read/write device and the display elements.   2))+]+]2))21+]+]+]2));;21SHUP2))21 5[' 7[' 7[' 5[' 3( 9 QF 9 QF 3((5535([IODVKHYHU\V6RFNHW 3LQDVVLJQPHQWUHDGHU/('VIRU352),%86'3*HQHUDOLQGLFDWRUV6)%)219'&DUHORFDWHGRQWKHEDVLFPRGXOHRIWKH(7;/('VIRU02%<5[' 5HDGHUDFWLYHZLWKFRPPDQG35( ,QGLFDWHVWKHSUHVHQFHRIDWUDQVSRQGHU(55 (UURULQGLFDWHGE\IODVKLQJVHTXHQFH7KHIROORZLQJ$60VWDWHVDUHDOVRLQGLFDWHGZLWKWKH/('V35(DQG(55'HVFULSWLRQ&DXVHV5HPHG\+DUGZDUHLVGHIHFWLYH5$0IODVK&KDUJHULVGHIHFWLYHFDQRQO\EHUHSDLUHGLQWKHIDFWRU\)LUPZDUHORDGLQJLVDFWLYHRUQRILUPZDUHGHWHFWHGൺ/RDGILUPZDUHൺ$60PXVWQRWEHVZLWFKHGRIIXQWLOORDGHG)LUPZDUHORDGLQJWHUPLQDWHGZLWKHUURUVൺ5HVWDUWUHTXLUHGൺ/RDGILUPZDUHDJDLQൺ&KHFNXSGDWHILOHV2SHUDWLQJV\VWHPHUURUൺ6ZLWFK$60RU(7;EDVHVWDWLRQ2))21$60KDVERRWHGDQGLVZDLWLQJIRUD5(6(7LQLWBUXQIURPWKHXVHU Figure 8-12  Interfaces and indicators of the ASM 473 for RF300
System integration   8.5 ASM 473  SIMATIC RF300 224  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.5.4 Configuration 9VXSSO\)RUUHDGHU9VXSSO\IRU(7;(OHFWURQLFV%DVLFPRGXOH(7;%0(7;%0(7;%0'(6,1$%0 $60bWRRWKHU352),%86EXVQRGHV352),%86'30DVWHUPRGXOH6,0$7,&b6HJ5)50'67DJ352),%86 Figure 8-13  Configuration of ASM 473   Note It differs from ASM 452 in that for ET 200X the 24 V supply must be connected to the PROFIBUS connector and on the load voltage connector (see the ET 200X manual).  Basic module - Requirements for operation of ASM 473  The following table indicates the status of the ET 200X basic module of 10/2002. The functionality of new basic modules is stored in HW Config of the SIMATIC Manager. Table 8- 6  Requirements for operation of ASM 473 Order number of the ET 200X basic module For operation with ASM 473 (6GT2002-0HA00)* For operation with ASM 473 PARAM (6GT2002-0HA10) 6ES7141-1BF00-0XB0  No  No 6ES7141-1BF00-0AB0  Yes  Yes 6ES7141-1BF01-0XB0  No  No 6ES7141-1BF10-0XB0  No  No
 System integration  8.5 ASM 473 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  225 Order number of the ET 200X basic module For operation with ASM 473 (6GT2002-0HA00)* For operation with ASM 473 PARAM (6GT2002-0HA10) 6ES7141-1BF11-0XB0  Yes  Yes 6ES7141-1BF40-0AB0  Yes  Yes 6ES7142-1BD10-0XB0  No  No 6ES7142-1BD11-0XB0  No  No 6ES7142-1BD20-0XB0  No  No 6ES7142-1BD21-0XB0  Yes  Yes 6ES7142-1BD22-0XB0  No  Yes** 6ES7143-1BF00-0AB0  Yes  Yes 6ES7143-1BF00-0XB0  Yes  Yes 6ES7147-1AA00-0XB0  No  No 6ES7147-1AA01-0XB0  No  Yes * Discontinued ** Notes on operation:  In HW Config, please parameterize the module 6ES7142-1BD21-0XB0.
System integration   8.5 ASM 473  SIMATIC RF300 226  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Example for a maximum configuration of ASM 473 on an ET 200X  5)[[75)[[56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)7 0D[$60FDQEHRSHUDWHGLQDQ(7; Figure 8-14  Example for a maximum configuration of ASM 473 on an ET 200X Depending on the PROFIBUS master, up to 123 ET 200X modules can be run on one PROFIBUS branch. Hardware configuration  The ASM 473 is integrated in the hardware configuration of the SIMATIC Manager by calling Setup.exe in the directory daten\S7_OM on the "RFID Systems Software & Documentation" CD. Currently, the ASM 473 cannot be integrated in masters of other manufacturers. Reader connection system  A reader always occupies the two M12 connection sockets X3 and X4 on the ASM 473. A prefabricated cable makes it easy to connect the reader. The standard version of the connecting cable is 2 m in length. Other cable lengths are available on request. For customers who want to assemble their own cables, an ASM cable connector with screw-
 System integration  8.5 ASM 473 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  227 type terminals is available. Cables and ASM cable connectors can be ordered from the MOBY catalog. 8.5.5 Technical data  Table 8- 7  Technical specifications for ASM 473 Interface for ET 200X  SIMATIC S7 I/O bus cyclic/acyclic services Communication  2 words cyclic/238 bytes acyclic Command buffer in ASM  142 x 238 bytes Serial interface to the reader    Connector  2 x M12 coupler plug  Max. cable length  2 m = standard length; other pre-assembled cables = 5 m, (up to 1000 m on request)  Readers that can be connected  1 x RF3xxR reader with RS422 Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45, FB 45, FC 55 MDS addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder, etc. PROFIBUS Diagnosis  Yes; in accordance with ET 200X basic station S7 diagnostics  Yes, can be called up via S7 OM Reloadable firmware  Yes, via S7 OEM Power supply 1   Rated value  24 V DC  Permissible range  20.4 V to 28.8 V DC Current consumption  Typ. 75 mA; max. 500 mA  (or see Technical specifications of the connected reader) Power dissipation of the module  Typically 1.6 W Digital outputs/inputs  Via expansion modules from the ET 200X spectrum Ambient temperature    Operation  0 °C to +55 °C  Transport and storage  -40 °C to +70 °C Dimensions (W x H x D) in mm    Single unit  87 x 110 x 55  Width module  60 x 110 x 55
System integration   8.5 ASM 473  SIMATIC RF300 228  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Fixing  2 M5 screws (customer side) 2 M3 screws (product side) Degree of protection  IP67 Weight, approx.  0.275 kg For installation instructions and general technical data, see the ET 200X manual. 8.5.6 Dimensional drawings Dimension drawing for mounting holes The figure below shows the dimensions for the position of the holes for the fixing screws for a basic module and an ASM 473 expansion module. %0 $60bQ[  Q 1XPEHURIH[SDQVLRQPRGXOHV)RU0IL[LQJVFUHZ Figure 8-15  Dimensions for fixing holes for basic modules and expansion modules Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQGWUXQFDWHGVKLHOGEUDLGLQJ Figure 8-16  Length of stripped insulation for PROFIBUS cables
 System integration  8.6 ASM 475 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  229 8.6 ASM 475 8.6.1 Features Area of application The ASM 475 interface module acting as the link between all RF300 systems and SIMATIC S7-300 performs the functions of a communication module. It can be operated centrally in the S7-300 or decentrally in an ET200M. As many as eight ASM 475 interface modules can be plugged into one SIMATIC S7-300 rack and operated. In a configuration with several racks (max. four), the ASM 475 can be plugged into and operated on any rack. This means that as many as 32 ASMs can be operated in the maximum configuration of a SIMATIC S7-300. The ASM can also be operated in the ET 200M distributed I/O on PROFIBUS. Operation in an S7-400 environment is therefore problem-free. Up to 8 ASMs can be operated on each ET200M. Error messages and operating states are indicated by LEDs. A configuration that is resistant to interference is possible due to electrical isolation between the read/write device and the SIMATIC S7-300 bus.  Figure 8-17  Interface module ASM 475 The ASM 475 with the order number 6GT2002-0GA10 is a parameterizable module. The basic functions of the module are then already specified when the module is configured in HW Config (e.g. standard addressing). The data in the MDS is accessed direct by means of physical addresses using the ASM 475. Operation in a SIMATIC S7 is controlled by the function FC 45. ASM 475 and FC 45 form a unit that is used for reading the data of the MDS easily and at optimal speed.
System integration   8.6 ASM 475  SIMATIC RF300 230  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.6.2 Ordering data Table 8- 8  Ordering data for ASM 475 and accessories Product description  Order No. ASM 475 interface module for SIMATIC S7  2 x RF3xxR reader with RS422 can be connected in parallel, without front connector 6GT2002-0GA10 Accessories:   Front connector (1 x per ASM)  6ES7392-1AJ00-0AA0 Connecting cable ASM 475 ↔ RF3xxR   Plug-in cable, pre-assembled, length: 2 m (standard length)  6GT2891-0EH20 Plug-in cable, pre-assembled, length: 5 m  6GT2891-0EH50 Terminal element (1 x per reader cable)  6ES7390-5BA00-0AA0 Shield connecting element  6ES7390-5AA00-0AA0 CD "RFID Systems Software & Documentation" with FC 45, S7 object manager 6GT2080-2AA10 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables.
 System integration  8.6 ASM 475 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  231 8.6.3 Indicators Bezel and indicator elements The figure below illustrates the bezel of the ASM 475 and the inside of the front door complete with the associated connection diagram. The read/write devices must be connected to the ASM in accordance with the connection diagram. 6WDWXVDQGHUURUGLVSOD\V &RQQHFWLRQGLDJUDP7KHQXPEHUVRIWKHFRQQHFWLRQVUHIHUWR&RQQHFWRU;RIWKHWRSHQFORVXUHVHFWLRQ$6002%<6/*b66((66((6)9'&$&7B(55B35(B5['B$&7B(55B35(B5['B6/*b*7b*$ Figure 8-18  Bezel and inside of the front door of the ASM 475 Display elements on the ASM Table 8- 9  Function of the LEDs on the ASM 475 Light emitting diode  Meaning SF  System fault (hardware error on ASM) DC 5V  24 V are connected to ASM and the 5 V voltage on ASM is OK. ACT_1, ACT_2  The corresponding reader is active in processing a user command. ERR_1, ERR_2  A flashing pattern indicates the last error to occur. This display can be reset using the parameter Option 1.
System integration   8.6 ASM 475  SIMATIC RF300 232  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Light emitting diode  Meaning PRE_1, PRE_2  Indicates the presence of a transponder. RxD_1, RxD_2  Indicates live communication with the reader. In the event of a fault on the reader, this display may also be lit. On the ASM 475, further operating states are indicated with the LEDs PRE, ERR and SF:  Table 8- 10  Operating status display on ASM 475 via LEDs SF  PRE_1  ERR_1  PRE_2  ERR_2  Meaning ON  OFF/ON  ON (perm.) OFF/ON  ON (perm.) Hardware is defective (RAM, Flash, etc.) ON  OFF  ON  OFF  OFF  Charger is defective (can only be repaired in the factory). OFF  2 Hz  OFF  2 Hz  OFF  Firmware loading is active or no firmware detected  Firmware download  ASM must not be switched off OFF  2 Hz  2 Hz  2 Hz  2 Hz  Firmware loading  terminated with errors  Restart required  Load firmware again  Check update files Any value 5 Hz  5 Hz  5 Hz  5 Hz  Operating system error  Switch ASM off/on OFF  OFF  1 flash every 2 s OFF  1 flash every 2 s ASM has booted and is waiting for a RESET (init_run) from the user.
 System integration  8.6 ASM 475 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  233 8.6.4 Configuration Centralized configuration with SIMATIC S7-300 352),1(7b,20DVWHUPRGXOH6,0$7,&b6$60FKDQQHO$60FKDQQHO$60bHJ5)56$GGLWLRQDOPRGXOHVIURPWKH6UDQJHLQFO$607DJV0'6HJ5)5 Figure 8-19  Configuration of ASM 475 central
System integration   8.6 ASM 475  SIMATIC RF300 234  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Distributed configuration with ET200M $60FKDQQHO$60FKDQQHO$60bHJ5)5(70$GGLWLRQDOPRGXOHVIURPWKH6UDQJHLQFO$60HJ5)57DJV0'6HJLQWHUIDFHPRGXOH Figure 8-20  Configuration of ASM 475 distributed Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables. &DEOHZLWKHQGVOHHYHVJUD\SLQN\HOORZEURZQZKLWHVKLHOG&DEOHVKLHOGH[SRVHG$60VLGH 5HDGHUVLGHJUHHQ6/*FRQQHFWRU6RFNHW0SLQ*7(ZLWKVWUDLJKW6/*FRQQHFWRUVWDQGDUG Figure 8-21  Installation of connecting cable between ASM 475 and RF300 reader with RS 422
 System integration  8.6 ASM 475 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  235 Cable installation   Signal  Pin on  M12 connector Cable  Labeling 24 V DC  1  white  1 Reader 2 8 -16 TX -  2  brown  1 Reader 2 7-15 GND  3  Green  1 Reader 2 9-17 TX +  4  Yellow  1 Reader 2 6-14 RX +  5  Gray  1 Reader 2 4-12 RX -  6  Pink  1 Reader 2 5-13      Shield  8 + terminal piece -   Cable assignment for connection of an RF300 reader to ASM 475 8.6.5 Technical data Table 8- 11  Technical data for ASM 475 Serial interface for SIMATIC S7-300 or  ET200M I/O bus; cyclic and acyclic services Communication  2 words cyclic/238 bytes acyclic Command buffer in ASM 475  70 x 238 bytes per RF310R reader Serial interface to the reader   Connector  Via screw-type terminal on front connector The front connector is not included in the scope of supply. Max. cable length  Pre-assembled cables = 2 m, 5 m, (up to 1000 m on request) Readers that can be connected  2 x RF3xxR reader with RS422 parallel mode Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45; FB 45; FC 55 Transponder addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder
System integration   8.6 ASM 475  SIMATIC RF300 236  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Multitag mode  No S7 data structures via UDTs  Yes Power supply   Rated value  24 V DC Permissible range  20.4 V to 28.8 V DC Current consumption   Without reader for U = 24 V DC, max.  350 mA With reader connected, max.  500 mA, per connected reader Power dissipation of the module, typ.  2 Watts Current consumption from I/O bus, max.  80 mA Electrical isolation between S7-300 and RF300  Yes Fuse 24 V for the reader  Yes, electronic Ambient temperature    During operation Horizontal installation of SIMATIC Vertical installation of SIMATIC  0 to +60 °C 0 to +40 °C Transport and storage  -40 to +70 °C Dimensions (W x H x D) in mm  40 x 125 x 120 Weight, approx.  0.2 kg
 System integration  8.7 RF170C SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  237 8.7 RF170C Configured with RF170C SIMATIC RF170CHJ5)5HJ5)57DJV0'6PROFIBUS orPROFINET/Industrial EthernetMaster moduleSIMATIC S7PROFINET/Industrial EthernetorInterface moduleET 200pro9IRU(7SUR5)&DQGUHDGHUPROFIBUS Figure 8-22  Configuration of RF170C For more detailed information, refer to SIMATIC RF170C Operating Instructions (http://support.automation.siemens.com/WW/view/en/32622825).
System integration   8.8 RF180C  SIMATIC RF300 238  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.8 RF180C Configured with RF180C ,QGXVWULDO(WKHUQHW352),1(7]%5)5]%5)57DJV0'6352),1(7b,20DVWHUPRGXOH6,0$7,&b69IRU5)&DQGUHDGHUWRRWKHU352),1(7EXVQRGHV6,0$7,&5)&9WRRWKHU352),1(7EXVQRGHV Figure 8-23  Configuration of RF180C For more detailed information, refer to SIMATIC RF180C Operating Instructions (http://support.automation.siemens.com/WW/view/en/30012157).
 System integration  8.9 RF182C SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  239 8.9 RF182C Configuration with RF182C ,QGXVWULDO(WKHUQHW]%5)5]%5)57DJV0'6352),1(7,29IRU5)&DQGUHDGHU7RDGGLWLRQDO352),1(7(WKHUQHWQRGHV6,0$7,&5)&3&PROFINET IOMaster moduleSIMATIC S7 Figure 8-24  Configuration with RF182C For more detailed information, refer to SIMATIC RF182C Operating Instructions (http://support.automation.siemens.com/WW/view/en/38507897).
System integration   8.10 8xIQ-Sense  SIMATIC RF300 240  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.10 8xIQ-Sense 8.10.1 Features Field of application The 8xIQ-Sense module is the link between the RF310R with 8xIQ-Sense interface and SIEMENS S7-300 and functions in the same manner as the communication module (interface module). It can be operated centrally in an S7-300 or decentrally in an ET200M.  Figure 8-25  8xIQ-Sense interface module 8.10.2 Ordering data Table 8- 12  Ordering data for 8xIQ-Sense and accessories  Order number  IQ-Sense SM338 for S7-300 and ET200M for the connection of up to 8xIQ-Sense sensors  Optical sensors, ultrasonic sensors and RF identification systems can be connected. 6ES7 3387XF000AB0  Table 8- 13  Ordering data for 8xIQ-Sense accessories  Order number M12 cable plug, 4-pole, with 5 m black PUR cable, 4 x 0.34 mm2 3RX8000-0CB42-1AF0 M12 cable plug, 4-pole, with 10 m black PUR cable, 4 x 0.34 mm2 3RX8000-0CB42-1AL0
 System integration   8.10 8xIQ-Sense SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  241  8.10.3 Indicators Status displays The 8xIQ-Sense module has the following LEDs:  A green LED, which has no function for RFID devices, and a red SF LED (system fault LED), which indicates the diagnostic state of the module.    LEDs  Labeling  LED status Meaning Green LED per channel 0…7   Has no function here Illuminated Module fault, sensor fault, active teach-in operation, external auxiliary voltage missing  6)60[,46HQVH;)$%;  Red  SF Not illuminated No fault or no active teach-in operation
System integration   8.10 8xIQ-Sense  SIMATIC RF300 242  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.10.4 Configuration Centralized configuration with SIMATIC S7-300 $60FKDQQHO$60FKDQQHO[,46HQVH6$GGLWLRQDOPRGXOHVIURPWKH6UDQJHLQFO[,46HQVH5HDGHUZLWK[,46HQVHLQWHUIDFH7DJV0'65HDGHUZLWK[,46HQVHLQWHUIDFH Figure 8-26  Configuration of 8xIQ-Sense central
 System integration   8.10 8xIQ-Sense SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  243 Distributed configuration with ET 200M $60FKDQQHO$60FKDQQHO[,46HQVH(70$GGLWLRQDOPRGXOHVIURPWKH6UDQJHLQFO[,46HQVH5HDGHUZLWK[,46HQVHLQWHUIDFH7DJV0'6HJLQWHUIDFHPRGXOH5HDGHUZLWK[,46HQVHLQWHUIDFH Figure 8-27  Configuration of 8xIQ-Sense distributed Table 8- 14  Pin assignment of RF310R with IQ-Sense interface Pin  Pin, device end, 4-pin M12  Assignment 1  IQ-Sense 2  Not used 3  IQ-Sense    4  Not used
System integration   8.10 8xIQ-Sense  SIMATIC RF300 244  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Configuration of connecting cable from 8xIQ-Sense to RF310R 6/*6WHFNHU0%XFKVH5HDGHU6HLWH,46HQVH6HLWHEUDXQEODX Figure 8-28  Cable and pin assignment of RF300 with IQ-Sense 8.10.5 Addressing The address range of the 8xIQ-Sense module is 16 bytes I/O.  This is independent of the choice of channel profiles on the connected device (i.e. the IQ profile IDs in HW Config). Access to memory areas A direct association exists between the number of the channel to which the IQ-Sense device is connected (terminal) and the input and output data area of the module. Based on the address range, the following addresses can be used to access the memory areas: Address = module initial address + (channel no. x 2) Example Module initial address = 280 I/O address for channel 3: 286
 System integration   8.10 8xIQ-Sense SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  245 ,46HQVHGHYLFH00ದ00ದ00ದ00ದ00ದ00ದ00ದ00ದ)URQW GRRULQWHULRUFKDQQHO7HUPLQDO&KDQQHODGGUHVVHVLQH[DPSOHIRU,46HQVHGHYLFHV&KDQQHOQRFKDQQHOFKDQQHOFKDQQHOFKDQQHOFKDQQHOFKDQQHOFKDQQHO,4,4,4,4,4,4,4,4/0IRU5),46HQVHGHYLFH,46HQVHGHYLFH,46HQVHGHYLFH,46HQVHGHYLFH,46HQVHGHYLFH,46HQVHGHYLFH,46HQVHGHYLFH5)55)5 Figure 8-29  8xIQ-Sense module: Assignment of terminal pair to memory area    Note A maximum of two read/write devices can be operated!  Each read/write device uses channel numbers 0 to 3 or 4 to 7.
System integration   8.10 8xIQ-Sense  SIMATIC RF300 246  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 8.10.6 Technical data  Voltages and currents   Rated supply voltage Reverse polarity protection 24 V DC  yes Galvanic isolation  Between the channels  Between channels and backplane bus  no yes Permissible potential difference Between different circuits  75 V DC / 60 V AC Insulation tested at  500 V DC Current input  from the backplane bus  from L+ power supply  120 mA typical 500 mA max. Module power loss  2.5 W typical Module-specific data  Number of channels Channels for RFID systems 8 2 Cable length, unshielded  50 m max. Dimensions and weight  Dimensions w x h x d (mm)  40 x 125 x 120 Weight   Approx. 235 g
 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  247 System diagnostics 99.1 Error codes Error codes of the RF300 readers   Flashing of red LED on reader Error code (hexa- decimal) Description 00  00  no error 02  01  Presence error, possible causes:  The active command was not carried out completely  The tag has left the field while the command is being processed  Communication fault between reader and tag 05  05  Parameterization error, possible causes:  Unknown command  Incorrect parameter  Function not allowed 06  06  Air interface faulty 12  0C  The tag memory cannot be written, possible causes:  Hardware fault (memory faulty)  Memory write-protected (corresponding OTP area has already been written) 13  0D  Error in the specified memory address (access attempted to non-existent or non-accessible memory areas). 19  13  Buffer overflow: Insufficient buffer available in the reader for saving the command 20  14  Major system fault (hardware fault) 21  15  Parameter assignment error: faulty parameter in RESET command 25  19  Previous command is still active 28  1C  Antenna is already switched off/Antenna is already switched on 30  1E  Incorrect number of characters in frame 31  1F  Running command cancelled by "RESET" command
System diagnostics   9.2 Diagnostics functions  SIMATIC RF300 248  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 9.2 Diagnostics functions 9.2.1 Overview Extended diagnostic functions with SIMATIC RF300 @ FB 45-Tabellen müssen noch hier reinverlinkt werden  With SIMATIC RF300, extended diagnostic functions are available which simplify commissioning and maintenance. This diagnostics data is accessed using the SIMATIC function blocks via the SLG Status and MDS Status commands. These two commands can each be called in various modes (subcommands) for which corresponding data structures (UDTs) are defined.  Table 9- 1  In RF300 mode Command  Mode (subcommand) Meaning 01  Hardware and firmware configuration, parameterization statusSLG status 06  Communication error counter, current command status 01  Serial number of the tag (UID), memory configuration EEPROM write-protection status MDS status 02  Serial number of the tag (UID), HF field strength value, communication error counter, presence counter (duration) Overview of the diagnostic functions  Table 9- 2  In ISO mode Command  Mode (subcommand) Meaning SLG status  01  Hardware and firmware configuration, parameterization statusMDS status  03  Serial number of the tag (UID), recognized tag type in the field (number = tag - type, see reset parameter "ftim"), memory configuration, write protect status (OTP), size and number of blocks in the user memory 9.2.2 Reader diagnostics with SLG Status The SLG STATUS command can be used to scan the status and diagnostics data of the reader.
 System diagnostics  9.2 Diagnostics functions SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  249 SLG STATUS (mode 01), corresponds to UDT 110  Name  Type  Possible values  Comment hardware  char  (31 to 38 hex)  Type of hardware hardware_version  word   0 to FF hex 0 to FF hex HW version = Version (high byte): Unused = Version (low byte) loader_version  word   0 to FF hex 0 to FF hex Version of loader = Version (high byte) = Version (low byte) firmware  char  0 to FF hex  Type of firmware firmware_version  word   0 to FF hex 0 to FF hex Firmware version = Version (high byte) = Version (low byte) driver  char   31 hex Type of driver  3964R driver_version  word   0 to FF hex 0 to FF hex Version of driver = Version (high byte) = Version (low byte) interface  byte   01 hex 02 hex Interface type = RS422 = RS232 (only RF380R) baud  byte   01 hex 03 hex 05 hex Baud rate = 19.2 Kbaud = 57.6 Kbaud = 115,2 Kbaud This variable is only provided for the RF380R. Users are therefore able to check the output power actually set. An incorrect value in the parameter "distance_limiting" of the RESET message frame results in the default setting "05".    Transmit power 02 hex  0.5 W 03 hex  0.75 W 04 hex  1,0 05 hex  1.25 W (default) 06 hex  1.5 W 07 hex  1.75 W distance_limiting_SLG  byte 08 hex  2.0 W multitag_SLG  byte    01 hex Number of MDSes (Multitag/Bulk) that can be processed in the antenna field = Single tag mode
System diagnostics   9.2 Diagnostics functions  SIMATIC RF300 250  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Name  Type  Possible values  Comment field_ON_time_SLG  byte  00 hex 01 hex 03 hex 04 hex 05 hex 06 hex 07 hex RF300 transponder ISO transponder (non-specific) ISO my-d (Infineon SRF 55V10P) ISO (Fujitsu MB89R118) ISO I-Code SLI (Philips SL2 ICS20) Tag-it HFI (Texas Instruments) ISO (ST LRI2K) status_ant  byte   01 hex 02 hex Status of antenna = Antenna On = Antenna Off MDS_control  byte   00 hex 01 hex Presence mode = Operation without presence message = Operation with presence message  SLG STATUS (mode 06), corresponds to UDT 280  Name  Type  Possible values  Comment FZP  byte  0 to FF hex  = Error counter, passive (errors during idle time) ABZ  byte  0 to FF hex  = Abort counter CFZ  byte  0 to FF hex  = Code error counter SFZ  byte  0 to FF hex  = Signature error counter CRCFZ  byte  0 to FF hex  = CRC error counter BSTAT  byte  0 to FF hex  = Current command status ASMFZ  byte  0 to FF hex  = Interface problems to host (ASM/PC) parity, BCC, frame error    Note All counter values are reset after reading (= SLG STATUS command executed).  Explanations: ● "FZP": Counts interference pulses when communication is not taking place with a transponder. (e.g. EMC interference caused by contactors, motors, etc.). However, counter values can also be generated when a tag is located at the edge of the field even when there is no external interference. ● "ABZ", "CFZ", "SFZ" and "CRCFZ" are counters for protocol errors which may occur during reader-tag communication. This can be caused by unsuitable reader/tag positioning (e.g. tag on field boundary, several data carriers in the field) or an external electromagnetic interference. To ensure clear diagnosis of the quality of communication, it is recommended that an SLG STATUS command (mode 06) is executed following receipt of the presence command to reset the error counter.
 System diagnostics  9.2 Diagnostics functions SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  251 The protocol error counters are not mutually independent. If a code error (CFZ) occurs, this will cause a signature (SFZ) or CRC- (CRCFZ) error. ● "BSTAT" is the status for the most recently executed command. A value other than 0 means that the previous command was repeated by the reader due to faults (see above). ● "ASMFZ" signals line-conducted communication interference between the communication module (ASM) and the reader. Faults of this type can be caused by contact problems on the connector or the cable connection. 9.2.3 Transponder diagnostics with MDS Status The MDS STATUS command can be used to scan the status and diagnostics data of the transponder that is located within the antenna field.  MDS Status (mode 01), corresponds to UDT 260, only for RF300 tags   Name  Type  Possible values  Comment UID  array[1…8] byte   0000000055555555 hex to 00000000 FFFFFFFF hex Unique identifier = b0-31: 4 byte TAG ID, b32-63: 0 MDS_type  byte   01 hex 02 hex 03 hex 04 hex Tag memory configuration = Transponder without FRAM = Transponder with FRAM 8 KB = Transponder with FRAM 32 KB = Transponder with FRAM 32 KB Lock_state  byte  0 to FF hex  EEPROM write protection status  (use graphic from UDT260 here)  MDS Status (mode 02), corresponds to UDT 270, only for RF300 tags  Name  Type  Possible values  Comment UID  array[1…8] byte   0000000055555555 hex to 00000000FFFFFFFF hex Unique identifier = b0-31: 4 byte TAG ID, b32-63: 0 LFD  byte  0 to FF hex  = Value for field strength determined in the tag FZP  byte  0 to FF hex  = Error counter (passive) ➙ errors during idle time FZA  byte  0 to FF hex  = Error counter (active) ANWZ  byte  0 to FF hex  = Presence counter
System diagnostics   9.2 Diagnostics functions  SIMATIC RF300 252  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04    Note All counter values are reset when the tag exits the field or when the antenna is switched off.  Explanations:  ● "LFD" is a value for the field strength that is determined in the transponder. The lower the value, the higher the field strength. ● "FZP" counts fault pulses when communication with a transponder is not taking place (e.g. electromagnetic interference caused by contactors, motors, etc.). Counter values can also be generated when a transponder is located at the edge of the field even when there is no external interference. ● "FZA" counts errors that can occur during reader-to-transponder communication. This can be caused by unsuitable reader/transponder positioning (e.g. transponder on field boundary, several data carriers in the field) or external electromagnetic interference. ● "ANWZ" is the value for the time that the transponder remains in the field before the MDS STATUS command (mode 02) is executed. A time step is 10 ms. The maximum time that can be recorded is therefore 2.5 s. MDS STATUS for ISO mode (mode 03) corresponds to UDT 230 Table 9- 3  MDS STATUS for ISO mode Name  Type  Possible values  Comment UID  array[1…8] byte   000000000 0000000 hex to FFFFFFFF FFFFFFFF hex Unique identifier =8 byte UID, MSB first MDS_type  byte   01 hex  03 hex 04 hex 05 hex 06 hex 07 hex Tag type (vendor, identification) = ISO general (non-specific or unknown) = my-d (Infineon) = MB89R118 (Fujitsu) = I-Code SLI (NXP) = Tag-it HFI (Texas Instruments) = LRI2K (ST) IC_version  byte  0 to FF hex   Chip version  size  byte  0 to FF hex  Memory size in bytes  Depending on tag type, e.g. my-d: 992 bytes
 System diagnostics  9.2 Diagnostics functions SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  253 Name  Type  Possible values  Comment lock_state  byte  0 to FF hex  Lock status, OTP information:  one bit is used per block (4 x 4 bytes or 2 x 8 bytes) (bit = 1: block is locked)  e.g. 01 = Block 1 of address FF80 - FF83 is locked or 03 = Block 1 and 2 of address FF80 - FF87 are locked,  e.g. for the Philips SL2 ICS20 (MDS D124, D160 or D100). This chip provides a usable memory (112 bytes EEPROM) from address 0000 - 006F (total OTP area 0060 - 006F). In this memory, the locked area corresponds to the addresses 0060 - 0063 or 0060 - 0067 block_size  byte  0 to FF hex  Block size of the transponder  Depending on tag type, e.g. my-d: 4 bytes nr_of_blocks  byte  0 to FF hex  Number of blocks  Depending on tag type, e.g. my-d: 248
 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  255 Appendix AA.1 Certificates and approvals  Certificate  Description    CE Approval to R&TTE Notes on CE marking The following applies to the system described in this documentation:  The CE marking on a device is indicative of the corresponding approval: DIN ISO 9001 certificate  The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems). EQ-Net certificate no.: 1323-01 Certifications for the United States, Canada, and Australia Safety  One of the following markings on a device is indicative of the corresponding approval:  Underwriters Laboratories (UL) per UL 60950 (I.T.E) or per UL 508 (IND.CONT.EQ)  Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950 (I.T.E) or C22.2 No. 142 (IND.CONT.EQ)  Underwriters Laboratories (UL) according to standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142 (IND.CONT.EQ)  UL recognition mark
Appendix   A.1 Certificates and approvals  SIMATIC RF300 256  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 One of the following markings on a device is indicative of the corresponding approval:  Canadian Standard Association (CSA) per Standard C22.2. No. 60950 (LR 81690) or per C22.2 No. 142 (LR 63533)  Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533) EMC   USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  Shielded Cables  Shielded cables must be used with this equipment to maintain compliance with FCC regulations. Modifications  Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Conditions of Operations  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   CANADA Canadian Notice  This Class A digital apparatus complies with Canadian ICES-003.   AUSTRALIA  This product meets the requirements of the AS/NZS 3548 Norm.
 Appendix  A.2 Accessories SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  257 A.2 Accessories CD "RFID Systems Software & Documentation" The CD contains: ● FB/FC for SIMATIC, 3964R ● Driver for DOS/Windows 95/NT/2000/XP ● C libraries ● PC demonstration program ● RFID documentation in PDF format, especially RFID system manuals, programming instructions and operating instructions  The "RFID Systems Software & Documentation" CD has a user-friendly interface based on HTML. After Start.exe has been called, a window for selecting the RFID system appears: ● RF300 ● RF600 ● RF-MANAGER ● MOBY ● CM/ASM After selecting the RFID system, you can navigate to the required information.  Product  Order number CD "RFID Systems Software & Documentation"  6GT2 080-2AA10    Note Notes on "RFID system software" and licensing When purchasing a communication module or an interface module, no software or documentation is supplied. The "RFID Systems Software & Documentation" CD-ROM contains all available FBs/FCs for the SIMATIC, C libraries, demo programs, etc. and needs to be ordered separately. In addition, the CD-ROM contains the complete RFID documentation (German, English and French) in PDF format. The purchase of a communication module or an interface module includes a payment for the use of the software, including documentation, on the "RFID Systems Software & Documentation" CD-ROM and the purchaser acquires the right to make copies (copy license) insofar as they are required as part of the customer-specific application or development for the plant. The enclosed contract pertaining to the use of software products against a one-off payment shall apply in addition.
Appendix   A.3 Connecting cable  SIMATIC RF300 258  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 A.3 Connecting cable In the following chapter, you will find an overview of the connecting cables between the readers and communication modules or PCs.  A.3.1 Reader RF3xxR (RS422) with ASM 452/ASM 473 A reader always occupies two M12 connection sockets on the ASM 452/ASM 473 A pre-assembled cable therefore ensures easy connection of the reader (see figure below). The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables.  JUD\JUHHQZKLWHEURZQ\HOORZSLQNVKLHOG7ZRSLQ0FLUFXODUFRQQHFWRUV$60VLGH 5HDGHUVLGH0SLQ ;;;;;;; ; ;; Figure A-1  Connecting cable between ASM 452/473 and RF3xxR reader with RS422 (6GT2891-1CH20)  A.3.2 Reader RF3xxR (RS422) with ASM 456/RF170C/RF180C 0FRQQHFWRUPDOH5HDGHUVLGH$60VLGH/ Figure A-2  Connecting cable between ASM 456, RF170C, RF180C and reader RF3xxR (RS422)
 Appendix  A.3 Connecting cable SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  259 Table A- 1  Ordering data Length L  Order number 2 m  6GT2891-0FH20 5 m  6GT2891-0FH50 10 m  6GT2891-0FN10 20 m  6GT2891-0FN20 50 m  6GT2891-0FN50  A.3.3 Reader RF3xxR (RS422) with ASM 475 Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables.  &DEOHZLWKHQGVOHHYHVJUD\SLQN\HOORZEURZQZKLWHVKLHOG&DEOHVKLHOGH[SRVHG$60VLGH 5HDGHUVLGHJUHHQ6/*FRQQHFWRU6RFNHW0SLQ*7(ZLWKVWUDLJKW6/*FRQQHFWRUVWDQGDUG Figure A-3  Installation of connecting cable between ASM 475 and RF300 reader with RS 422
Appendix   A.3 Connecting cable  SIMATIC RF300 260  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 A.3.4 RF310R and IQ-Sense The connecting cable is available in lengths of 5 m (standard) and 10 m. 6/*6WHFNHU0%XFKVH5HDGHU6HLWH,46HQVH6HLWHEUDXQEODX Figure A-4  Configuration of connecting cable from 8xIQ-Sense to RF310R  Length  Order number 5 m  3RX8000-0CB42-1AF0 10 m  3RX8000-0CB42-1AL0  A.3.5 Reader RF380R (RS232) - PC The connecting cable (6GT2891-0KH50) is 5 m long.  Special feature of the cable: additional branch for the power supply. 5HDGHUVLGHSROH0SLQ68%'SLQ3&6RFNHW Figure A-5  Connecting cable RF380R (RS232) to the PC Suitable power supply unit: e.g. wide-range power supply unit
 Appendix  A.4 Ordering data SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  261 Table A- 2  Ordering data for wide-range power supply unit Wide-range power supply unit for SIMATIC RF-systems  (100 - 240 V AC / 24 V DC / 3 A)  with 2 m connecting cable with country-specific plug EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 A.4 Ordering data RF300 components  Table A- 3  RF300 reader  Readers  Description  Order number RF310R (IQ-Sense)  With IQ-Sense interface  IP 67  Operating temperature: -25 °C to +70 °C  Dimensions: 55 x 75 x 30 (L x W x H, in mm)  with integrated antenna 6GT2801-0AA00 RF310R (RS422)  With RS422 interface (3964R)  IP 67  Operating temperature: -25 °C to +70 °C  Dimensions: 55 x 75 x 30 (L x W x H, in mm)  with integrated antenna  ISO 15693 compatible 6GT2801-1AB10 RF340R  With RS422 interface (3964R)  IP 67  Operating temperature -25 °C … +70 °C  Dimensions 75 x 91 x 41 (L x W x H in mm)  with integrated antenna 6GT2801-2AB10 RF350R  With RS422 interface (3964R)  IP 65  Operating temperature: -25 °C … +70 °C  Dimensions: 75 x 96 x 41 (L x W x H, in mm)  For pluggable antennas ANT 1, ANT 12, ANT 18, ANT 30 6GT2801-4AB10 RF380R  With RS422 interface (3964R)  IP 67  Operating temperature: -25 °C … +70 °C  Dimensions: 160 x 96 x 40 (L x W x H, in mm)  with integrated antenna  ISO 15693 compatible 6GT2801-3AB10
Appendix   A.4 Ordering data  SIMATIC RF300 262  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Table A- 4  Antennae  Antenna  Description  Order number ANT 1  IP67  Operating temperature: -25 °C to +70 °C  Dimensions: 75 x 75 x 20 (L x W x H, in mm) 6GT2398-1CB00 ANT 12  IP67  Operating temperature: -25 °C to +70 °C  Dimensions: M18 x 1.0 x 55 6GT2 398-1CC00 ANT 18  IP67 (front)  Operating temperature -25 °C to +70 °C  Dimensions: M18 x 50 (Ø x L in mm) 6GT2398-1CA00 ANT 30  IP67 (front)  Operating temperature -25 °C to +70 °C  Dimensions: M30 x 58 (Ø x L in mm) 6GT2398-1CD00   Table A- 5  RF300 transponder  RF300 transponder  Description  Order number RF320T  IP67  Memory size: 20 byte EEPROM  Operating temperature: -25 °C to +85 °C  Dimensions: 27 mm x 4 mm (Ø x H in mm) 6GT2800-1CA00 RF340T  IP68  Memory size: 8 KB FRAM  Operating temperature: -25 °C to +85 °C  Dimensions: 48 x 25 x 15 (L x W x H, in mm) 6GT2800-4BB00 RF350T  IP68  Memory size: 32 KB FRAM (read/write) and 4 byte EEPROM (read only)  Operating temperature: -25 °C … +85 °C  Dimensions: 50 x 50 x 20 (L x W x H, in mm) 6GT2800-5BD00 RF360T  IP67  Memory size: 8 KB FRAM (read/write) and 4 byte EEPROM (read only)  Operating temperature: -25 °C … +75 °C  Dimensions: 85.8 x 54.8 x 2.5 (L x W x H, in mm) 6GT2800-4AC00 RF370T (32 KB FRAM)  IP68  Memory size: 32 KB FRAM  Operating temperature: -25 to +85 °C  Dimensions: 75 x 75 x 40 (L x W x H, in mm) 6GT2800-5BE00
 Appendix  A.4 Ordering data SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  263 RF300 transponder  Description  Order number RF370T (64 KB FRAM)  IP68  Memory size: 64 KB FRAM  Operating temperature: -25 °C to +85 °C  Dimensions: 75 x 75 x 40 (L x W x H, in mm) 6GT2800-6BE00 RF380T  IP68  Memory size 32 KB FRAM (read/write) and 4 byte EEPROM  Operating temperature -25 … +200 °C (cyclic)  Dimensions: 114 x 83 (Ø x H in mm) 6GT2800-5DA00   Table A- 6  ISO transponder ISO transponder  Description  Order number MDS D100  IP68  Memory size: 112 byte EEPROM  Operating temperature: -25 … +80 °C  Dimensions: 85.6 x 54 x 0.9 (L x W x H, in mm)  ISO card 6GT2600-0AD10 MDS D124  IP67  Memory size: 112 byte EEPROM user memory  Operating temperature: -25 … +125 °C  Dimensions: 27 mm x 4 mm (Ø x H in mm) 6GT2600-0AC00 MDS D139  IP68  Memory size: 112-byte user memory  Operating temperature: up to +200 °C/+220 °C [heat-resistant (r/w)]  Dimensions: 85 x 15 (Ø x H in mm) 6GT2600-0AA10 MDS D160  IP68 (24 hours, 2 m, +20 °C)  Memory size: 112 byte user memory  Operating temperature: -25 °C...+70 °C  Dimensions: 16 x 3 ±0.1 (Ø x H in mm)  Laundry tag for cyclical applications (r/w) 6GT2600-0AB10  MDS D324  IP67  Memory size: 992 byte EEPROM user memory  Operating temperature: -25 °C...+125 °C  Dimensions: 27 x 4 (Ø x H in mm) 6GT2600-3AC00 MDS D421  IP67/x9K  Memory size: 2000 byte user memory  Operating temperature: –25 °C to +85 °C  Dimensions: 10 x 4.5 (Ø x H in mm) 6GT2600-4AE00 MDS D424  IP67  Memory size: 992 byte EEPROM user memory  Operating temperature: -25 °C ...+125 °C  Dimensions: 27 x 4 (Ø x H in mm) 6GT2600-4AC00
Appendix   A.4 Ordering data  SIMATIC RF300 264  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 ISO transponder  Description  Order number MDS D428  IP68; IP x9K  Memory size: 2000 byte FRAM user memory  Operating temperature: -25 °C ...+85 °C  Dimensions (D x H): 18 mm x 20 mm (without thread), tolerance 1 mm; M8 thread 6GT2600-4AK00 MDS D460  IP68  Memory size: 2000 byte FRAM user memory  Operating temperature: -25 °C ...+85 °C  Dimensions: 16 x 3 ±0.1 (Ø x H in mm) 6GT2600-4AB00   Table A- 7  Communication modules/interface modules  ASM/ communication module Description  Order number ASM 452  for PROFIBUS DP-V1,  1x RF3xxR with RS422 interface  without connector for 24 V DC and PROFIBUS 6GT2002-0EB20 ASM 456  for PROFIBUS DP-V1  For connecting as many as 2 readers 6GT2002-0ED00 ASM 473  1x RF3xxR reader with RS422 can be connected  6GT2002-0HA10 ASM 475  For SIMATIC S7  2 x readers RF3xxR with RS422 can be connected in parallel without a front connector 6GT2002-0GA10 Communication module, 1 unit  6GT2002-0HD00 RF170C Connection module, 1 unit  6GT2002-1HD00 RF180C communication module  max. 2 SLGs or readers can be connected 6GT2002-0JD00 Connection block M12, 7/8" PN  6GT2002-1JD00 RF180C Push-pull connection block, RJ45  6GT2002-2JD00 RF182C communication module  Max. 2 SLGs or readers can be connected 6GT2002-0JD10 Connection block M12, 7/8'' (5-pole)  6GT2002-1JD00 Connection block M12, 7/8'' (4-pole)   6GT2002-4JD00 RF182C Push-pull connection block, RJ45  6GT2002-2JD00 8xIQ-Sense  ● IQ-Sense SM338 for S7-300 and ET200M for the connection of up to 8xIQ-Sense sensors ● Optical sensors, ultrasonic sensors and RF identification systems can be connected. 6ES7 3387XF000AB0
 Appendix  A.4 Ordering data SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  265 Accessories Table A- 8  Accessories for RF300 reader Readers  Accessories  Order number RF380R  Connecting cable RS232 to PC  6GT2891-0KH50  Table A- 9  Accessories for RF300 tags Tag  Accessories  Order number Spacers  6GT2190-0AA00 RF360T Fixing pocket  6GT2190-0AB00 Holder (short version)  6GT2090-0QA00 Holder (long version)  6GT2090-0QA00-0AX3 Covering hood  6GT2090-0QB00 RF380T Universal holder  6GT2590-0QA00  Table A- 10  Accessories for ISO tags MDS  Accessories   Order number Spacers  6GT2190-0AA00 Fixing pocket  6GT2190-0AB00 MDS D100 Fixing pocket  (cannot be mounted directly on metal) 6GT2390-0AA00 MDS D139  Spacer [85 mm x 30 mm (Ø x H in mm)]  6GT2690-0AA00  Table A- 11  Connecting cable accessory - ASM/communication module to reader ASM - Reader  Description   Order number Length  2 m  6GT2891-1CH20 ASM 452/ ASM 473  and reader RF3xxR with RS422 5 m  6GT2891-1CH50 Length  2 m  6GT2891-0FH20 5 m  6GT2891-0FH50 10 m  6GT2891-0FN10 20 m  6GT2891-0FN20 ASM 456/RF170C/ RF180C  and reader RF3xxR (RS422) 50 m  6GT2891-0FN50 Length  ASM 475 and reader  2 m  6GT2891-0EH20
Appendix   A.5 Service & Support  SIMATIC RF300 266  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 ASM - Reader  Description   Order number RF3xxR (RS422)  5 m  6GT2891-0EH50 Length  5 m  3RX8000-0CB42-1AF0 8xIQ-Sense and RF310R 10 m  3RX8000-0CB42-1AL0  Table A- 12  RFID accessories, general RFID accessories, general  Order number CD "RFID Systems Software & Documentation"  6GT2 080-2AA10 Wide-range power supply unit for SIMATIC RF systems  (100 - 240 V AC/24 V DC/3 A)  with 2 m plug-in cable with country-specific connector EU: 6GT2898 0AA00 UK: 6GT2898 0AA10 US: 6GT2898 0AA20 A.5 Service & Support Contact partner If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office.  The addresses are found on the following pages: ● On the Internet (www.siemens.com/automation/partner) ● In Catalog CA 01 ● In Catalog FS 10 specially for factory automation sensors Technical Support  You can access technical support for all IA/DT projects via the following: ● Phone: + 49 (0) 180 5050 222  (€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible) ● E-mail (mailto:support.automation@siemens.com) ● Internet: Online support request form: (www.siemens.com/automation/support-request)  Service & support for industrial automation and drive technologies You can find various services on the Support homepage (www.siemens.com/automation/service&support) of IA/DT on the Internet.  There you will find the following information, for example:
 Appendix  A.5 Service & Support SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  267 ● Our newsletter containing up-to-date information on your products. ● Relevant documentation for your application, which you can access via the search function in "Product Support". ● A forum for global information exchange by users and specialists. ● Your local contact for IA/DT on site. ● Information about on-site service, repairs, and spare parts. Much more can be found under "Our service offer". RFID homepage For general information about our identification systems, visit RFID homepage (www.siemens.com/simatic-sensors/rf). Technical documentation on the Internet A guide to the technical documentation for the various products and systems is available on the Internet:  SIMATIC Guide manuals (www.siemens.com/simatic-tech-doku-portal) Online catalog and ordering system  The online catalog and the online ordering system can also be found on the A&D Mall homepage. (www.siemens.com/automation/mall) Training center  We offer appropriate courses to get you started. Please contact your local training center or the central training center in  D-90327 Nuremberg. Phone: +49 (0) 180 523 56 11 (€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible) For information about courses, see the SITRAIN homepage (www.sitrain.com).
 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  269 Glossary
 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  271 Index 8 8xIQ-Sense module Addressing, 244 Indicators, 241 Ordering data, 241 A Antennae Minimum clearances, 121 Application Planning SIMATIC RF300, 27 Approvals, 255 ASM 452 Configuration, 214 Indicators, 213 Operating mode, 215 Ordering data, 212 Pin assignments, 213 PROFIBUS address and terminating resistor, 217 PROFIBUS configuration, 214 Reader connection system, 215 ASM 473 Design and function, 221 Dimensions, 228 Features, 221 Hardware configuration, 226 Maximum configuration of an ET 200X, 226 Notes on operation, 224 Ordering data, 222 Pin assignments, 223 Reader connection system, 226 Technical specifications, 227 ASM 475 Assignment for connecting cable, 234, 259 Cable installation, 235 Design and function, 229 Function of the LEDs, 231 Indicators, 231 Ordering data, 230 Pin assignment, 234, 259 Status display with LEDs, 232 C Cabinet configuration, 92 Cable, 258 Reader - ASM, 258 Shielding, 96 Calculation example, 39 Certificates, 255 Chemical resistance of the MDS MDS D139, 83 MDS D160, 86 Combinations Reader-tag, 18 Communication modules, 17, 209 Communication time Calculating, 37 Connecting cable Reader-communication module/ASM/PC, 258 Contact partner, 266 Conventions, 12, 20 Coupling paths, 91 Courses, 267 Customer benefits, 21 D Data transmission rate MDS D100, 55 MDS D124, 56 MDS D139, 57 MDS D160, 58 MDS D324, 59, 60, 61, 62 RF320T, 49 RF340T, 50 RF350T, 51 RF360T, 52 RF370T, 53 RF380T, 54 Design System Manual, 11 Detection area, 35 Diagnostic functions Transponder, 251 Direction of motion Transponder, 35 Display elements
Index    SIMATIC RF300 272  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF310R reader with IQ-Sense interface, 101 RF310R reader with RS422 interface, 105, 110, 115, 126 RF340R reader, 110 Dwell time Transponder, 36 Dynamic mode, 36 Dwell time of the transponder, 36 E Electromagnetic compatibility Coupling paths, 91 Electromagnetic interference, 89 EMC Directives Propagation of electromagnetic interference, 89 EMC Guidelines, 256 Avoiding interference, 94 Basic Rules, 88 Cabinet configuration, 92 Cable shielding, 97 Definition, 87 Equipotential bonding, 95 Overview, 86 Equipotential bonding, 95 Error codes Readers, 247 F FC 45, 248 Features of ASM 452 interface module Area of application, 211 Field data RF310R reader, 44 Fields of application, 20 Fixing pocket for MDS D100, 174 Flush-mounting of transponders and readers, 64 H High-performance, 16 I Inductive alternating field, 27 Input parameter, 209 Installation Several readers, 64 Installation guidelines, 62 Interface modules, 209 Interference sources Electromagnetic, 90 IQ-Sense interface Pin assignment, 100, 243 ISO functionality, 99 L LEDs For MOBY, 223 for PROFIBUS DP, 223 Low-performance, 16 M Main applications, 20 MDS STATUS, 248 Medium-performance, 16 Memory configuration of the RF300 tags, 134 Metal Influence on the transmission window, 66 Metal-free area Reader RF310R, 101, 106 Reader RF340R, 110, 127 Transponder RF320T, 136 Transponder RF340T, 140 Transponder RF350T, 143 Transponder RF360T, 147 Transponder RF370T, 152 Transponder RF380T, 159 Minimum clearances Antenna to antenna, 121 Minimum distance Antenna to antenna, 48 Reader to reader, 48 Transponder to transponder, 47 O Ordering data, 261 8xIQ-Sense module, 241 Antennae, 262 Interface modules/communication Modules, 264 Overview, 261 Readers, 261 RF300 transponder, 262 RF310R with IQ-Sense, 100
 Index   SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04  273 P Parameterization Function blocks, 209 PROFIBUS cable Stripped lengths, 228 R Read/write distance, 27 Reader RF310R Display elements, 101 Metal-free area, 101, 106 Pin assignment of IQ-Sense interface, 100 Reader RF340R Metal-free area, 110, 127 Readers, 99 Mounting, 64 Reducing interference due to metal, 63 Reduction of field data by metal RF340R, 68, 69 RF350R with ANT 1, 70, 71, 72 RF350R with ANT 18, 72, 73 RF350R with ANT 30, 74 RF380R, 67, 75, 76 Resistance to chemicals Transponder, 77 RF310R reader, 100, 104, 113, 125 Characteristics, 100, 104, 113, 125 Minimum distance, 102, 106 Pin assignment of IQ-Sense interface, 243 RF340R reader, 109 Characteristics, 109 RF370T transponder/32 KB FRAM Technical specifications, 154 RFID systems Overview, 15 S Selection criteria SIMATIC RF300 components, 27 Shielding, 97 SIMATIC RF300 Diagnostic functions, 248 SLG STATUS, 248 Spacers, 175 Static mode, 35 Dwell time of the transponder, 36 System diagnostics MDS status, 251 Overview, 248 System overview RFID systems, 15 T Technical documentation On the Internet, 267 Technical specifications RF370T transponder/32 KB FRAM, 154 Transponder RF320T, 138 Transponder RF340T, 141 Transponder RF350T, 144, 150 Transponder RF360T, 150 Technical Support, 266 Time constants, 38, 39 Tolerance of pallet side transport, 40 Tolerance of pallet transport height, 39 Tracking Tolerance, 32 Tracking tolerances, 32 Training, 267 Transmission gaps, 41 Transmission window ANT18 and ANT30 (RF350R), 30 Impact of metal, 66 RF310R reader and ANT1 (RF350R), 28 RF340R reader, 29 RF380R reader, 31 Width, 32 Transponder Detection area, 35 Directions of motion, 35 Dwell time, 36 Mounting on metal, 65 Resistance to chemicals, 77 Transponder RF320T Characteristics, 136 Metal-free area, 136 Technical specifications, 138 Transponder RF340T Characteristics, 139 Metal-free area, 140 Technical specifications, 141 Transponder RF350T Characteristics, 142 Metal-free area, 143 Technical specifications, 144 Transponder RF360T Characteristics, 147 Metal-free area, 147 Technical specifications, 150 Transponder RF370T
Index    SIMATIC RF300 274  System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Characteristics, 151 Metal-free area, 152 Transponder RF380T Metal-free area, 159 U User data Calculate maximum number, 37 Calculating, 37

Navigation menu