 Communication modules  7.3 ASM 452 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  171 7.3 ASM 452 7.3.1 Features Area of application The ASM 452 interface module is a MOBY module for operating MOBY and RF300 components with RS422 over PROFIBUS DP-V1 on ● Any computers and PCs ● Any PLCs When operating the interface module on a SIMATIC S7, function blocks are made available to the user.  Figure 7-6  Interface module ASM 452 The ASM 452 is the result of consistent development of the familiar ASM 450/451 interface modules. Optimal data throughput can be achieved even in large-scale PROFIBUS configurations thanks to the use of acyclic data traffic on PROFIBUS DP V1. The minimum cyclic data load of the ASM 452 on the PROFIBUS provides the user with the guarantee that other PROFIBUS nodes (e.g. DI/DO) can still be processed at great speed. The ASM 452 is an interface module for communication between PROFIBUS and the RF310R with RS422 interface. Through the ASM 452, the data on the RF300 transponder can be physically addressed ("Normal" addressing). In SIMATIC S7, FC 45 is available for this purpose.
Communication modules   7.3 ASM 452  SIMATIC RF300 172 System Manual, 06/2008, A5E01642529-02 7.3.2 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignments of ASM 452. 352),%86'36RFNHW;DQG;3LQDVVLJQPHQW 6LJQDO % UHG 3( 3( 6LJQDO $ JUHHQ / 06XSSO\YROWDJH/('VIRU5)DQG$605[' 5HDGHU DFWLYH ZLWK35((55 7UDQVSRQGHUSUHVHQWRUHUURU GLVSOD\35((55 IRUUHDGHU7KHWUDQVSRQGHUSUHVHQWGLVSOD\DOZD\VWDNHVSULRULW\7KHHUURULVRQO\LQGLFDWHGZKHQDWUDQVSRQGHULVQRWSUHVHQW7UDQVSRQGHUSUHVHQW7KH/('LVSHUPDQHQWO\21,IPRUHWKDQRQHWUDQVSRQGHULVLQWKHILHOGWKH  QXPEHURIWUDQVSRQGHUVLVLQGLFDWHGE\VKRUWLQWHUUXSWLRQV$IDXOWLVQRWRXWSXW(UURUGLVSOD\7KH/('LVSHUPDQHQWO\2))7KHODVWHUURUQXPEHULVLQGLFDWHGE\EULHIOLJKWSXOVHV5HDGHU 5HDGHULVVHOHFWHG5HDGHU 5HDGHULVVHOHFWHG2QO\UHDGHUFDQEHVHOHFWHG/('VIRU352),%86'36) 6\VWHP )DXOW%) %XV )DXOW21 /LJKWV XS ZKHQ WKHUH LV$60LVJHQHUDWHGE\WKH9VXSSO\YROWDJH9'& /LJKWVXSZKHQWKH9VXSSO\YROWDJHLVFRQQHFWHGWRWKH$601RWFRQQHFWHG3LQDVVLJQPHQWUHDGHU6RFNHW1RWDYDLODEOHIRU5);;;;$60; ;; ;;;;'&95['35((556/*5['6/*35((556)%)21 3( / 0 3( / 0; 5[' 7[' 7[' 5[' 3(; ;  9 9 '$ '(  9 9 '$ '( 3( 3( Figure 7-7  Pin assignment and LEDs of ASM 452
 Communication modules  7.3 ASM 452 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  173 7.3.3 Configuration Configuration Hardware description The ASM 452 has the same housing as the distributed I/O system ET 200X. General information on ASM 452 (e.g. assembly, operation and wiring; general technical data) is available in the ET200X manual (Order No. 6ES7 198-8FA00-8AA0). Descriptions of accessories and network components can also be found in this manual. Configuration 5)[[75)[[5352),%86FDEOHV9IRU$60WRRWKHU352),%86QRGHV352),%86'3PDVWHUPRGXOHHJ6&386,0$7,&5)56,0$7,&5)7 Figure 7-8  ASM 452 configurator
Communication modules   7.3 ASM 452  SIMATIC RF300 174  System Manual, 06/2008, A5E01642529-02 PROFIBUS configuration The ASM 452 is integrated into the hardware configuration by means of a GSD file. The ASM can then be configured using the HW Config of SIMATIC Manager or another PROFIBUS tool. A GSD file is provided for ASM 452 on the CD "RFID Systems Software & Documentation". Operating mode of the ASM 452 The approved operating modes of ASM 452 are described in the GSD file. It is set using the hardware configuration tool (e.g. STEP 7 HW Config). Reader connection system A reader always occupies two M12 connector sockets on the ASM 452. A pre-assembled cable therefore ensures easy connection of the reader (see figure below). The connecting cable is available in lengths of 2 m (standard) and 5 m. Extensions are possible up to 1000 m using connecting cables 6GT2891-… .  JUD\JUHHQZKLWHEURZQ\HOORZSLQNVKLHOG7ZRSLQ0FLUFXODUFRQQHFWRUV$60VLGH 5HDGHUVLGH0SLQ ;;;;;;; ; ;; Figure 7-9  Connecting cable (2 m) ASM 452/473 ↔ RF3xxR reader with RS422 (6GT2891-1CH20)
 Communication modules  7.3 ASM 452 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  175 Cable installation  Signal  M12 (reader side)  Cable  X1 / Data  X2 24 V DC  1  Pink  -  1 TX -  2  Yellow  4  - GND  3  Gray  -  3 TX +  4  Green  1  - RX +  5  white  2  - RX -  6  brown  3  - -      -  - Shield  8 + terminal piece  Shield  5  5 Cable assignment ASM 452/473 ↔ RF3xxR reader with RS422 (6GT2891-1CH20) A reader cable connector with screw-type terminals is provided for users who want to individually pre-assemble their own cables (see figure below). Cables and reader cable connectors can be ordered from the MOBY catalog.  66VFUHZVIRURSHQLQJWKHFRQQHFWRU&RQQHFWRU0WR$60'HJUHHRISURWHFWLRQ,33*FDEOHJODQGPD[FDEOHGLDPHWHU PPRQO\VFUHZGRZQDIWHUDVVHPEOLQJWKHFRQQHFWRU$60FDEOH*7 &RQQHFWRUFRYHUUHPRYHG Figure 7-10  Cable connector ASM 452/473 ↔ RF3xx reader with RS422 (6GT2090-0BC00)  Pin assignment for ASM 452/473 cable connector  Connector pin  Connection to pin of the reader  Wire color 1  4 2  5 3  6 4  2 5  3 6  1  - S  8 + terminal piece Note data sheet provided by the manufacturer Pin 7 must not be connected.
Communication modules   7.3 ASM 452  SIMATIC RF300 176 System Manual, 06/2008, A5E01642529-02 PROFIBUS cable with 24 V supply The ASM 452 can also be operated with the "green" PROFIBUS cable. It is important to ensure that a 24 V cable is connected from X12 to X13. The 24 V cable can be connected to pins 5 and 6 in plug X12. ; ;;; ;; Figure 7-11  PROFIBUS cable with 24 V supply PROFIBUS address and terminating resistor You must remove the connector plate from the ASM before you set the  PROFIBUS address or connect the terminating resistor. The connector plate covers the DIL switch. The position of the DIL switch in ASM is shown in the figure below with one setting example for each case. 212IIRQ  ([DPSOH352),%86DGGUHVVRQGHOLYHU\([DPSOH7HUPLQDWLQJUHVLVWRU2II $VGHOLYHUHGVWDWH6WDQGDUGPRGHXVH*6'ILOH6,(0%   Figure 7-12  Setting the PROFIBUS address/connecting the terminating resistor   Note • The PROFIBUS address in ASM 452 must always match the PROFIBUS address defined in the configuring software for this ASM. • To ensure that the terminating resistor functions correctly, you must always switch both DIL switches of the terminating resistor to "on" or "off".
 Communication modules  7.3 ASM 452 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  177 7.3.4 Technical data Table 7-3  Technical data for ASM 452   ASM 452 with FC 45 Serial interface to the user  PROFIBUS DP-V1 Procedure after connection  EN 50170 Vol. 2 PROFIBUS  PG 11 cable gland PROFIBUS and power supply connectors are not included in the scope of delivery Transmission rate  9600 baud to 12 Mbaud (automatic detection) Max. block length  2 words cyclic/240 bytes acyclic Serial interface to the RF3xxR   Connector  2 x M12 coupler plug Max. cable length  2 m = Standard length, 5 m, 10 m, 20 m and 50 m, (up to 1000 m on request) Readers that can be connected  1x RF3xxR with RS422 interface Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45 Transponder addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder Multi-tag capability  No S7 data structures via UDTs  Yes Power supply   Rated value  24 V DC Permissible range  20 V to 30 V DC Current consumption  Max. 180 mA; typ. 130 mA (without reader) Digital inputs  none Digital outputs  None Ambient temperature   During operation  0 °C to +55 °C Storage and transport  -40 °C to +70 °C Dimensions (W x H x D) in mm  134 x 110 x 55 (without bus connector) Fixing  4 M5 screws; for mounting on any plate or wall Weight, approx.  0,5 kg Degree of protection  IP67 MTBF (at 40 °C)  30 • 104 hours = 34 years
Communication modules   7.3 ASM 452  SIMATIC RF300 178 System Manual, 06/2008, A5E01642529-02 7.3.5 PROFIBUS Diagnosis The following table lists possible error indications with their meanings and provides remedies. Table 7-4  LED indication for PROFIBUS diagnosis "BF" LED  "SF"LED  Cause of error  Error correction • ASM 452 is in start-up mode.  - • The connection to the DP master has failed. • ASM 452 not detecting a baud rate. • Check the PROFIBUS DP connection. • Check the DP master. ON  * • Bus interrupt • DP Master not functioning • Check all cables on your PROFIBUS DP network. • Check whether the connector plugs for PROFIBUS DP are securely plugged into the ASM 452. flashes  on  • The configuration data sent to the ASM 452 by the DP master do not match the configuration of the ASM 452. • Check the configuration of the ASM 452 (input/output, PROFIBUS address). • Correct GSD file being used?– SIEM80B6.GSD for ASM 452 Flashes  Off  • ASM 452 has detected the baud rate, but is not being addressed by the DP Master. • ASM 452 has not been configured. • Check the PROFIBUS address set on the ASM 452 or in the configuration software. • Check the configuration of the ASM 452 (station type). on  Flashes  • There is a hardware defect in the ASM 452. • Replace the ASM 452.
 Communication modules  7.3 ASM 452 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  179 7.3.6 Dimension drawing The following figure shows the dimensional drawing of an ASM 452 with bus connectors. You must add the length of the PG cable gland and the radius of the cable used to the measured overall width and depth.   Figure 7-13  Dimensional drawing of ASM 452 Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQGWUXQFDWHGVKLHOGEUDLGLQJ Figure 7-14  Length of stripped insulation for PROFIBUS cables
Communication modules   7.3 ASM 452  SIMATIC RF300 180 System Manual, 06/2008, A5E01642529-02 7.3.7 Ordering data Table 7-5  Ordering data for ASM 452 and accessories Product description  Order No. ASM 452 interface module for PROFIBUS DP-V1, 1x RF3xxR with RS422 interface, without connector for 24 V DC and PROFIBUS 6GT2002-0EB20 Accessories: Connector for PROFIBUS DP and 24 V supply  6ES7194-1AA00-0XA0 Connecting cable RF3xxR ↔ ASM 452  Plug-in cable, pre-assembled, length: 2 m (standard length)  6GT2891-1CH20  Plug-in cable, pre-assembled, length: 5 m  6GT2891-1CH50 Opt. Cable connector without read/write device cable  (for cable lengths > 20 m) ASM 452 ↔ reader 6GT2090-0BC00 M12 blanking cap for unused RF310R connection (1 pack = 10 pieces) 3RX9802-0AA00 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 Replacement part: Connector plate; T functionality for PROFIBUS connection  6ES7194-1FC00-0XA0 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables.
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  181 7.4 ASM 456 7.4.1 Description Field of application The ASM 456 interface modules are slave modules for operating RF300 components via the PROFIBUS DP/DP-V1 on any control systems.  Figure 7-15  Interface module ASM 456 with ECOFAST connection block or M12, 7/8" When operating the interface module on a SIMATIC S7, convenient function blocks are made available to the user.
Communication modules   7.4 ASM 456  SIMATIC RF300 182 System Manual, 06/2008, A5E01642529-02 Features The ASM 456 replaces the ASM 452 in terms of functionality and provides a simplified connection system. You can continue to use the user software from ASM 452. Optimum data throughput can be achieved through acyclic data traffic on the PROFIBUS DP V1 even when using large PROFIBUS configurations. The minimum cyclic data load of the ASM 456 on the PROFIBUS provides the user with the guarantee that other PROFIBUS consumers (e.g. DI/DO) can still be processed at great speed. Up to 2 readers can be operated in parallel on the ASM 456. The user can start a command in parallel on 2 readers (via the corresponding FB/FC). The transponder data are accessed by means of physical addressing of the reader. In SIMATIC S7, the FC 45 is available for this purpose. The FC 45 provides the S7 user with a simple-to-use interface with powerful commands (processing one complete transponder with one command; command linking; S7 data structures via UDTs). Other features ● Degree of protection IP67 ● System integration with ECOFAST or M12, 7/8" concept ● T functionality, that is, a component can be replaced without adversely affecting other modules with regard to bus communication and voltage supply ● Standardized PROFIBUS user interface for identification systems with PIB (Proxy Ident Function Block; with later firmware version). ● Firmware update ● PROFIBUS interface module up to 12 Mbaud with automatic baud rate detection ● Parameterizable device-related diagnostics data with text display ● Support for I&M functionality (a mechanism for reading out information via the module and saving system information such as function, installation date, installation location, and comments.)
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  183 Design The ASM 456 has the same housing as the distributed I/O system ET 200eco. The ASM has a connection block for connecting up to the PROFIBUS DP which is available as an option and the ECOFAST version or M12, 7/8". The following figure shows the basic design of the ASM 456.  &RQQHFWRUVRFNHWIRUVWUHDGHU6WDWXV/('VIRURSHUDWLRQRIWKHQGUHDGHU6WDWXV/('VIRULQWHUIDFHPRGXOH5HDGHU6WDWXV/('VIRURSHUDWLRQRIWKHVWUHDGHU&RQQHFWRUVRFNHWIRUQGUHDGHU6SDFHIRUFRQQHFWLRQEORFN3URWHFWLYHHDUWK;;*7('02%<$60 Figure 7-16  Basic design of the ASM 456
Communication modules   7.4 ASM 456  SIMATIC RF300 184 System Manual, 06/2008, A5E01642529-02 Configuration The following figure shows how the ASM 456 is integrated in an automation system. 6,0$7,&5)76,0$7,&5)76,0$7,&5)56,0$7,&5)5;P6WDQGDUGFDEOHOHQJWK352),%86FDEOHV9IRU$60DQGUHDGHUWRRWKHU352),%86QRGHV352),%86'3PDVWHUPRGXOHHJ6&385HDGHU 5HDGHU7UDQVSRQGHU;$60b Figure 7-17  ASM 456 configurator  The ASM 456 is integrated into the hardware configuration by means of a GSD file. The ASM can then be configured using HW Config of SIMATIC Manager or another PROFIBUS tool (e.g. operating mode). The GSD file can be found on the "RFID Systems Software & Documentation" CD or on the Internet.
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  185 7.4.2 Setting the PROFIBUS address Features The PROFIBUS address defines the address at which the ASM 456 distributed I/O system is found on the PROFIBUS DP. Requirements ● The PROFIBUS DP address for the ASM 456 is set on the connection block. ● Each address can be assigned only once on the PROFIBUS DP. ● The PROFIBUS address set must match the PROFIBUS address defined in the configuring software (for the ASM 456). ● Changes to the PROFIBUS DP address only take effect once the mains have been switched ON on the ASM 456. Tools required for M12, 7/8” connection block ● Socket wrench 14 mm ● Screwdriver with 2.5 mm blade
Communication modules   7.4 ASM 456  SIMATIC RF300 186 System Manual, 06/2008, A5E01642529-02 Setting PROFIBUS DP addresses on connection block M12, 7/8” Valid PROFIBUS DP addresses are 1 to 99.  1. Remove the two seal caps from the rotary switches (if necessary, use a 14 mm socket wrench). 2. Set the required PROFIBUS address on the rotary switches using a screwdriver. – Lower rotary switch: 1st position – Upper rotary switch: 10th position 3. Screw the two seal caps back onto the rotary switches  (torque: 0.5 Nm to 0.8 Nm.) [[[[5RWDU\VZLWFKIRU352),%86'3DGGUHVV3RVLWLRQ3RVLWLRQ352),%86DGGUHVV([DPSOH Figure 7-18  Setting PROFIBUS addresses on connection block M12, 7/8”
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  187 Setting PROFIBUS DP addresses on connection block ECOFAST Valid PROFIBUS DP addresses are 1 to 99.  1. Loosen the screw connection of the configuration plug with the ECOFAST connection block and remove the plug.  Figure 7-19  Loosening the configuration plug's screw connection 2. Loosen the screw connection for the cover cap on the configuration plug and remove the latter. 3. Set the PROFIBUS address using the DIL switches. ([DPSOH352),%86DGGUHVV  21 21  Figure 7-20  Setting PROFIBUS address on configuration plug 4. Screw the cover cap back down, plug the configuration plug onto the connection block and screw the configuration plug to the connection block.
Communication modules   7.4 ASM 456  SIMATIC RF300 188 System Manual, 06/2008, A5E01642529-02 7.4.3 Wiring up ASM 456 Wiring ECOFAST connector plugs The table below contains the connector assignment for the ECOFAST connector plugs Table 7-6  Connection assignment for ECOFAST connector plugs Pin  Assignment  View of ECOFAST connector plug  (wiring end for supply and loop-through connection) A  PROFIBUS DP signal A B  PROFIBUS DP signal B 1  Electronics / encoder supply (1L+) (voltage supply for ASM 456 and reader) 2  Ground for electronic / encoder supply (1M) 3  Ground for load voltage supply (2M) 4  Load voltage supply (2L+) (unused on ASM 456)  $%//6LJQDO$6LJQDO%(&2)$67K\EULGFDEOH  *) You will find the assembly instructions in the packaging of the Han Brid Cu cable connector and/or Han Brid Cu cable socket.
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  189 Wiring M12, 7/8" connector The tables below contain the connector assignment for the M12, 7/8" connector: Table 7-7  Connection assignment for M12 connector (PROFIBUS DP) Pin  Assignment  View of M12 connector  (wiring side) 1  Supply positive (P5V2) * 2  Data line A (RxD / TxD-N) 3  Data reference potential (M5V2) * 4  Data line B (RxD / TxD-P) 5  Shield Thread  Shield  6LJQDO$JUHHQ6LJQDO%UHG6KLHOG6XSSO\'36LJQDO$JUHHQ6LJQDO%UHG6KLHOG%XVFDEOHFRUHVKLHOGHG/RRSWKURXJKFRQQHFWLRQ'3 *) Can only be used for the M12 terminating resistor. Looping the voltage through to the next connector via a 5-core cable is not permitted.  Table 7-8  Terminal assignment of the 7/8" connector (supply voltages) Pin  Assignment  View of 7/8" connector  (wiring side) 1  Ground for load voltage supply (2M) 2  Electronics/sensor supply ground (1M) 3  PE 4  Electronics / encoder supply (1L+) (voltage supply for ASM 456 and reader) 5  Load voltage supply (2L+) (unused on ASM 456)  ////6XSSO\;FRUHFDEOH/RRSWKURXJKFRQQHFWLRQ;
Communication modules   7.4 ASM 456  SIMATIC RF300 190 System Manual, 06/2008, A5E01642529-02   Note When connecting up the supply voltage, we recommend that the cable 6XV1 822-5B... (5 x 1.5 mm2 pre-assembled with 7/8" connectors) is used. If you want to assemble the cable yourself, then the conductor cross-section should be 1.5 mm2.  Connecting the ASM 456 up to protective earth 1. Isolate the grounding cable and secure the cable lug. 2. Screw the cable lug down to the ASM 456 (M5 retaining bolt). The torque is 3 Nm.  Figure 7-21  Connecting the ASM 456 up to protective earth Connecting RF310 reader to ASM 456 O Figure 7-22  Connecting cable, l = 2 m, 5 m, 10 m, 20 m, 50m ( 6GT2891-0Fxxx)  Maximum cable length The ASM 456 can be operated with any SLG configuration with a maximum cable length of 50 m. Longer connecting cables of up to 1000 m are possible in some instances. The current consumption of the connected reader must however be taken into account. A number of cables must not be joined together to form a long cable due to the additional contact resistances.
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  191 Cable assembly by the customer A reader connection plug with screw-type terminals is available for users who want to make their own cables.  Cables and reader cable connectors can be ordered according to the MOBY catalog. For self-assembled cables, you will need cable to the following specifications: 7 x 0.25 mm2 LiYC11Y 7 x 0.25 M12 connectors can be purchased from appropriate electrical retailers (e.g. Binder in Germany). The pin assignment is listed in the following table. Table 7-9  Pin assignment M12 connector (male)  Pin  Signal  Wire color 1  +24 V 2  −RxD 3  0 V 4  RxD 5  TxD 6  −TxD 7  Free   8  PE / shield Note data sheet provided by cable manufacturer
Communication modules   7.4 ASM 456  SIMATIC RF300 192 System Manual, 06/2008, A5E01642529-02 7.4.4 Diagnosis using LEDs The following figure shows details of the LEDs of the ASM 456. 352),%866) %) 21 '&9;;*7('02%<$60$&7B 35(B5['B (55B$&7B 35(B5HDGHU5HDGHU5['B (55B Figure 7-23  LEDs of the ASM 456 Table 7-10  Status LEDs for ASM 456 LEDs  Meaning* ON  Lights up when there is logic voltage at the ASM (is generated by the 24 V supply voltage.)  24 V DC  Lights up when the 24 V supply voltage is connected to the ASM. ACT_1, ACT_2  The corresponding reader is active in processing a user command. ERR_1, ERR_2 *  A flashing pattern indicates the last error to occur. PRE_1, PRE_2 **  Indicates the presence of a transponder. RxD_1, RxD_2  Indicates live communication with the reader. May also indicate malfunctions on the transponder. *) The meaning of the individual flash patterns and the associated fault descriptions can be found in      the relevant FB and FC documentation. **) In multitag mode, this LED uses a flash interval to indicate the number of data media currently       within the range of influence of the reader.
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  193 Table 7-11  LED display for PROFIBUS diagnosis BF  SF  Cause of error  Error handling • ASM is in start-up mode.  – • Connection to DP Master failed. • ASM not detecting a baud rate • Check the PROFIBUS DP connection. • Check the DP Master On  – • Bus interrupt • DP Master not functioning • Check all cables on your PROFIBUS DP network. • Check whether the connector plugs for the PROFIBUS DP are securely plugged into the ASM. flashes  On  • The project data sent to the ASM by the DP Master do not match the configuration of the ASM. • Check the project for the ASM (input/output, PROFIBUS address). • Correct GSD file being used? flashes  –  • ASM has detected the baud rate, but is not activated by the DP Master. • ASM has not been assigned project plans. • Check the PROFIBUS address set in ASM and/or in the project software. • Check the project for the ASM (station type). On  flashes  • There is a hardware defect in the ASM. • Replace the ASM. Off  On  • Diagnosis available  • Evaluate the diagnostic information. On  Off  • The set PROFIBUS address is incorrect or greater than 99. • Set the address in the range 1 to 99 and carry out new ramp-up. – = Status not relevant  Other ASM operating modes are indicated by the PRE, ERR, ACT, SF and ON LEDs:   ON  SF  PRE_1  ERR_1  ACT_1  PRE_2  ERR_2  ACT_2  Description On  Off  Off  Off  On  Off  Off  Off  Ramp-up active Off  On  Off  On  Off  Off  Off  Off  Checksum error at ramp-up Off  On  Off  Off   Off  Off  On  Off  Firmware invalid On  On  On  On  On  On  On  On  LED test for approximately 4 seconds; otherwise firmware fault Off  On  Off  On  On  Off  On  On  Checksum error at ramp-up Off  On  On  On  On  Off  On  On  Checksum error of the firmware Off  On  On  On  On  On  On  On  External RAM defective Off  On  On  Off  On  On  On  On  DPC-RAM defective Off  On  Off  On  On  On  On  On  ID error firmware On  –  Off  1 x flash every 3 s Off  Off  1 x flash every 3 sOff  ASM successfully ramped up, waiting for reset command On  –  –  Flashing  Rapid flashing –  Flashing  Rapid flashing Firmware update; alternate flashing of the error LEDs at approximately 1 Hz – = not relevant
Communication modules   7.4 ASM 456  SIMATIC RF300 194 System Manual, 06/2008, A5E01642529-02 7.4.5 Technical data Table 7-12  Technical data for ASM 456 Serial interface to the user  PROFIBUS DP-V1 Procedure after connection  EN 50170 Vol. 2 PROFIBUS M12 and 7/8" technology / ECOFAST Transmission rate  9600 baud to 12 Mbaud (automatic detection) Max. block length  2 words cyclic/240 bytes acyclic Serial interface to the reader   • Connector  2 x M12 coupler plug • Max. cable length  1000m, reader dependent; 2 m = Standard length; (up to 1000 m on request) Extension cable = 2 m, 5 m, 10 m, 20 m and 50 m• Readers that can be connected  2 x reader Software functions   Programming  Depending on the PROFIBUS DP master Function blocks:   • SIMATIC S5  – • SIMATIC S7  FC 45 (normal addressing without multitag) Transponder addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder, etc. Supply voltage: 2  • Rated value  24 V DC • Permissible range  20 V to 30 V DC Current consumption 1  Max. 800 mA; typ. 80 mA (without reader) Galvanic isolation  Yes Ambient temperature    • During operation  0 °C to +55 °C • Storage and transport  –40 to +70 °C Dimensions (W x H x D) in mm   • ASM 456 only  60 x 210 x 30 • ASM 456 with ECOFAST connection block  60 x 210 x 60 Weight, approx.  210 g Degree of protection  IP67 MTBF (at 40 °C)  122 years 1) The power supply must deliver the required current of up to 800 mA for brief power failures ≤ 20 ms. 2) All supply voltages and signal voltages must be protective low level voltage (SELV/PELV acc. to EN 60950) 24V DC supply: Safety (electrical) isolation of low voltage (SELV / PELV acc. to EN 60950)
 Communication modules  7.4 ASM 456 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  195 7.4.6 Dimension drawing The following figure shows the dimensional drawing of an ASM 456 with bus connection block.  [[[[02%<$6002%<$60[[:LWKFRQQHFWLRQEORFN0 :LWKFRQQHFWLRQEORFN(&2)$67   Figure 7-24  Dimensional drawing of ASM 456 (in mm)
Communication modules   7.4 ASM 456  SIMATIC RF300 196 System Manual, 06/2008, A5E01642529-02 7.4.7 Ordering data Table 7-13  Ordering data for ASM 456 and accessories Product description  Order No. ASM 456 interface module  for PROFIBUS DP V1 max. 2 readers can be connected 6GT2002-0ED00 Accessories for ECOFAST connection: Connection block ECOFAST  6ES7194-3AA00-0AA0 PROFIBUS ECOFAST hybrid plug 180   with pin insert (5 per pack)  6GK1905-0CA00 with socket insert (5 per pack)  6GK1905-0CB00 PROFIBUS ECOFAST termination plug with terminating resistor  6GK1905-0DA10 ECOFAST hybrid cable, pre-assembled  6XV1830-7B... 1) ECOFAST hybrid cable, not pre-assembled, sold by the meter  6XV1830-7AH10 Accessories for M12 7/8" connection: Connection block M12  6ES7194-3AA00-0BA0 M12 terminal resistor for PROFIBUS (5 per pack)  6GK1905-0EC00 PROFIBUS cable with M12 connectors, pre-assembled   6XV1830-3D... 1) Cable for supply voltage with pre-assembled 7/8" connectors  6XV1822-5B... 1) PROFIBUS FC standard non-pre-assembled cable;  max. length 1000 m 6XV1830-0EH10  PROFIBUS M12 connector plug (5 per pack) with pin insert  6GK1905-0EA00 with socket insert  6GK1905-0EB00 Connector plug 7/8" for voltage (5 per pack) with pin insert  6GK1905-0FA00 with socket insert  6GK1905-0FB00 Cable accessories:  Plug-in cable, pre-assembled, length 2 m (standard length)  6GT2891-0FH20 Plug-in cable, pre-assembled, length 5 m  6GT2891-0FH50 Plug-in cable, pre-assembled, length 10 m  6GT2891-0FN10 Plug-in cable, pre-assembled, length 20 m  6GT2891-0FN20 Plug-in cable, pre-assembled, length 50 m  6GT2891-0FN50 Angled extension for direct connection of reader to ASM 456 or for extending any plug-in cables 6GT2891-0JH20 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 Other accessories for ASM 456 (network components)  ET 200eco manual  6ES7198-8GA00-8AA0 Description of FC 45 (for ASM 456) German English French  Available in electronic form on the CD "RFID Systems Software & Documentation" 1) These cables are available in different lengths. See Catalog IK PI for more details
 Communication modules  7.5 ASM 473 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  197 7.5 ASM 473 7.5.1 Features Field of application The ASM 473 interface module is an RF300 module for SIMATIC S7. It can be plugged into the ET 200X distributed I/O station and DESINA. ET 200X is operated by the user over PROFIBUS DP V1. An S7-300 or S7-400 with integrated PROFIBUS connection can be used as the controller.  ASM 473 supplements the SIMATIC S7 interface module ASM 475. The IP67 degree of protection means that it can be installed and operated in the process without the need for an additional protective housing. To operate the ASM 473, an ET 200X basic module BM 141/142 with the order number 6ES7141-1BF11-0XB0 or 6ES7142-1BD21-0XB0 or a BM 143 is required. The transponder data are accessed by means of physical addressing of the transponder. For operation in a SIMATIC S7, the function FC 45 is available. The hardware of the ASM 473 is configured with an object manager (OM) that is integrated in the SIMATIC Manager.  Figure 7-25  Interface module ASM 473 Other features: ● Up to 7 ASM 473 interface modules can be operated simultaneously in an ET 200X station.  ● Any other I/O modules from the ET 200X spectrum can be operated with the ASM 473.
Communication modules   7.5 ASM 473  SIMATIC RF300 198 System Manual, 06/2008, A5E01642529-02 7.5.2 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignment for the read/write device and the display elements.    2))+]+]2))21+]+]+]2));;21SHUP2))21 5[' 7[' 7[' 5[' 3( 9 QF 9 QF 3((5535([IODVKHYHU\V6RFNHW 3LQDVVLJQPHQWUHDGHU/('VIRU352),%86'3*HQHUDOLQGLFDWRUV6)%)219'&DUHORFDWHGRQWKHEDVLFPRGXOHRIWKH(7;/('VIRU02%<5[' 5HDGHUDFWLYHZLWKFRPPDQG35( ,QGLFDWHVWKHSUHVHQFHRIDWUDQVSRQGHU(55 (UURULQGLFDWHGE\IODVKLQJVHTXHQFH7KHIROORZLQJ$60VWDWHVDUHDOVRLQGLFDWHGZLWKWKH/('V35(DQG(55'HVFULSWLRQ&DXVHV5HPHG\+DUGZDUHLVGHIHFWLYH5$0IODVK&KDUJHULVGHIHFWLYHFDQRQO\EHUHSDLUHGLQWKHIDFWRU\)LUPZDUHORDGLQJLVDFWLYHRUQRILUPZDUHGHWHFWHGൺ/RDGILUPZDUHൺ$60PXVWQRWEHVZLWFKHGRIIXQWLOORDGHG)LUPZDUHORDGLQJWHUPLQDWHGZLWKHUURUVൺ5HVWDUWUHTXLUHGൺ/RDGILUPZDUHDJDLQൺ&KHFNXSGDWHILOHV2SHUDWLQJV\VWHPHUURUൺ6ZLWFK$60RU(7;EDVHVWDWLRQ2))21$60KDVERRWHGDQGLVZDLWLQJIRUD5(6(7LQLWBUXQIURPWKHXVHU Figure 7-26  Interfaces and indicators of the ASM 473 for RF300
 Communication modules  7.5 ASM 473 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  199 7.5.3 Configuration 5)[[75)[[59VXSSO\IRU5)[[59VXSSO\IRU(7;(OHFWURQLFVWRRWKHU352),%86QRGHV352),%86'3PDVWHUPRGXOHHJ6&38FRQQHFWLRQRIDQRQ6LHPHQVPDVWHUSRVVLEOHVRRQ%DVLFPRGXOH(7;%0(7;%0'(6,1$%0352),%86FDEOHV6,0$7,&5)56,0$7,&5)7 Figure 7-27  Example - Configurator for ASM 473   Note It differs from ASM 452 in that for ET 200X the 24 V supply must be connected to the PROFIBUS connector and on the load voltage connector (see the ET 200X manual).
Communication modules   7.5 ASM 473  SIMATIC RF300 200 System Manual, 06/2008, A5E01642529-02 Basic module - Requirements for operation of ASM 473 The following table indicates the status of the ET 200X basic module of 10/2002. The functionality of new basic modules is stored in HW Config of the SIMATIC Manager. Table 7-14  Requirements for operation of ASM 473 Order number of the ET 200X basic module For operation with ASM 473 (6GT2002-0HA00)* For operation with ASM 473 PARAM (6GT2002-0HA10) 6ES7141-1BF00-0XB0  No  No 6ES7141-1BF00-0AB0  Yes  Yes 6ES7141-1BF01-0XB0  No  No 6ES7141-1BF10-0XB0  No  No 6ES7141-1BF11-0XB0  Yes  Yes 6ES7141-1BF40-0AB0  Yes  Yes 6ES7142-1BD10-0XB0  No  No 6ES7142-1BD11-0XB0  No  No 6ES7142-1BD20-0XB0  No  No 6ES7142-1BD21-0XB0  Yes  Yes 6ES7142-1BD22-0XB0  No  Yes** 6ES7143-1BF00-0AB0  Yes  Yes 6ES7143-1BF00-0XB0  Yes  Yes 6ES7147-1AA00-0XB0  No  No 6ES7147-1AA01-0XB0  No  Yes * Discontinued ** Notes on operation:      In HW Config, please parameterize the module 6ES7142-1BD21-0XB0.
 Communication modules  7.5 ASM 473 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  201 Example for a maximum configuration of ASM-473 on an ET 200X 5)[[75)[[56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)56,0$7,&5)7 0D[$60FDQEHRSHUDWHGLQDQ(7; Figure 7-28  Example for a maximum configuration of ASM 473 on an ET 200X Depending on the PROFIBUS master, up to 123 ET 200X modules can be run on one PROFIBUS branch. Hardware configuration The ASM 473 is integrated in the hardware configuration of the SIMATIC Manager by calling Setup.exe in the directory daten\S7_OM on the "RFID Systems Software & Documentation" CD. Currently, the ASM 473 cannot be integrated in masters of other manufacturers. Reader connection system A reader always occupies the two M12 connection sockets X3 and X4 on the ASM 473. A prefabricated cable makes it easy to connect the reader. The standard version of the connecting cable is 2 m in length. Other cable lengths are available on request. For customers who want to assemble their own cables, an ASM cable connector with screw-type terminals is available. Cables and ASM cable connectors can be ordered from the MOBY catalog.
Communication modules   7.5 ASM 473  SIMATIC RF300 202 System Manual, 06/2008, A5E01642529-02 7.5.4 Technical data  Table 7-15  Technical specifications for ASM 473 Interface for ET 200X  SIMATIC S7 I/O bus cyclic/acyclic services Communication  2 words cyclic/238 bytes acyclic Command buffer in ASM  142 x 238 bytes Serial interface to the reader   • Connector  2 x M12 coupler plug • Max. cable length  2 m = standard length; other pre-assembled cables = 5 m, (up to 1000 m on request) • Readers that can be connected  1 x RF3xxR reader with RS422 Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45 MDS addressing  Direct access via addresses Commands  Initialize transponder, read data from transponder, write data to transponder, etc. PROFIBUS Diagnosis  Yes; in accordance with ET 200X basic station S7 diagnostics  Yes, can be called up via S7 OM Reloadable firmware  Yes, via S7 OEM Power supply 1  • Rated value  24 V DC • Permissible range  20.4 V to 28.8 V DC Current consumption  Typ. 75 mA; max. 500 mA  (or see Technical specifications of the connected reader) Power dissipation of the module  Typically 1.6 W Digital outputs/inputs  Via expansion modules from the ET 200X spectrum Ambient temperature   • During operation  0 °C to +55 °C • During transport and storage  -40 °C to +70 °C Dimensions (W x H x D) in mm   • Single unit  87 x 110 x 55 • Width module  60 x 110 x 55 Fixing  2 M5 screws (customer side) 2 M3 screws (product side) Degree of protection  IP67 Weight, approx.  0.275 kg For installation instructions and general technical data, see the ET 200X manual.
 Communication modules  7.5 ASM 473 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  203 7.5.5 Dimensional drawings Dimension drawing for mounting holes The figure below shows the dimensions for the position of the holes for the fixing screws for a basic module and an ASM 473 expansion module. %0 $60bQ[  Q 1XPEHURIH[SDQVLRQPRGXOHV)RU0IL[LQJVFUHZ Figure 7-29  Dimensions for fixing holes for basic modules and expansion modules Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQGWUXQFDWHGVKLHOGEUDLGLQJ Figure 7-30  Length of stripped insulation for PROFIBUS cables
Communication modules   7.5 ASM 473  SIMATIC RF300 204 System Manual, 06/2008, A5E01642529-02 7.5.6 Ordering data Table 7-16  Ordering data for ASM 473 and accessories Product description  Order No. Interface module ASM 473 1x RF3xxR reader with RS422 interface   6GT2002-0HA10 Accessories:   Connecting cable ASM 473 ↔ Reader RF3xxR   Plug-in cable, pre-assembled, length 2 m (standard length)  6GT2891-1CH20 Plug-in cable, pre-assembled, length 5 m  6GT2891-1CH50 Opt. Cable connector without reader cable  (for cable lengths > 20 m) ASM 473 ↔ Reader 6GT2090-0BC00 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation"
 Communication modules  7.6 ASM 475 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  205 7.6 ASM 475 7.6.1 Features Area of application The ASM 475 interface module acting as the link between all RF300 systems and SIMATIC S7-300 performs the functions of a communication module. It can be operated centrally in the S7-300 or decentrally in an ET200M. As many as eight ASM 475 interface modules can be plugged into one SIMATIC S7-300 rack and operated. In a configuration with several racks (max. four), the ASM 475 can be plugged into and operated on any rack. This means that as many as 32 ASMs can be operated in the maximum configuration of a SIMATIC S7-300. The ASM can also be operated in the ET 200M distributed I/O on PROFIBUS. Operation in an S7-400 environment is therefore problem-free. Up to 8 ASMs can be operated on each ET200M. Error messages and operating states are indicated by LEDs. A configuration that is resistant to interference is possible due to electrical isolation between the read/write device and the SIMATIC S7-300 bus.  Figure 7-31  Interface module ASM 475 The ASM 475 with the order number 6GT2002-0GA10 is a parameterizable module. The basic functions of the module are then already specified when the module is configured in HW Config (e.g. standard addressing). The data in the MDS is accessed direct by means of physical addresses using the ASM 475. Operation in a SIMATIC S7 is controlled by the function FC 45. ASM 475 and FC 45 form a unit that is used for reading the data of the MDS easily and at optimal speed.
Communication modules   7.6 ASM 475  SIMATIC RF300 206 System Manual, 06/2008, A5E01642529-02 7.6.2 Indicators Bezel and indicator elements The figure below illustrates the bezel of the ASM 475 and the inside of the front door complete with the associated connection diagram. The read/write devices must be connected to the ASM in accordance with the connection diagram. 6WDWXVDQGHUURUGLVSOD\V &RQQHFWLRQGLDJUDP7KHQXPEHUVRIWKHFRQQHFWLRQVUHIHUWR&RQQHFWRU;RIWKHWRSHQFORVXUHVHFWLRQ$6002%<6/*b66((66((6)9'&$&7B(55B35(B5['B$&7B(55B35(B5['B6/*b*7b*$ Figure 7-32  Bezel and inside of the front door of the ASM 475
 Communication modules  7.6 ASM 475 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  207 Display elements on the ASM Table 7-17  Function of the LEDs on the ASM 475 Light emitting diode  Meaning SF  System fault (hardware error on ASM) DC 5V  24 V are connected to ASM and the 5 V voltage on ASM is OK. ACT_1, ACT_2  The corresponding reader is active in processing a user command. ERR_1, ERR_2  A flashing pattern indicates the last error to occur. This display can be reset using the parameter Option 1. PRE_1, PRE_2  Indicates the presence of a transponder. RxD_1, RxD_2  Indicates live communication with the reader. In the event of a fault on the reader, this display may also be lit. On the ASM 475, further operating states are indicated with the LEDs PRE, ERR and SF:  Table 7-18  Operating status display on ASM 475 via LEDs SF  PRE_1  ERR_1  PRE_2  ERR_2  Meaning ON  OFF/ON  ON (perm.) OFF/ON  ON (perm.) Hardware is defective (RAM, Flash, etc.) ON  OFF  ON  OFF  OFF  Charger is defective (can only be repaired in the factory). OFF  2 Hz  OFF  2 Hz  OFF  Firmware loading is active or no firmware detected • Firmware download • ASM must not be switched off OFF  2 Hz  2 Hz  2 Hz  2 Hz  Firmware loading  terminated with errors • Restart required • Load firmware again • Check update files Any value 5 Hz  5 Hz  5 Hz  5 Hz  Operating system error • Switch ASM off/on OFF  OFF  1 flash every 2 s OFF  1 flash every 2 s ASM has booted and is waiting for a RESET (init_run) from the user.
Communication modules   7.6 ASM 475  SIMATIC RF300 208 System Manual, 06/2008, A5E01642529-02 7.6.3 Configuration Centralized configuration with SIMATIC S7-300 6,0$7,&5)56,0$7,&5)56,0$7,&5)76,0$7,&5)72WKHUPRGXOHVIURPWKH6UDQJHLQFOXGLQJ$60$60FKDQQHO5HDGHUZLWK56LQWHUIDFH5HDGHU5HDGHU7UDQVSRQGHU7UDQVSRQGHU$60b6 Figure 7-33  Configurator for ASM 475 with RF310R reader (centralized configuration)
 Communication modules  7.6 ASM 475 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  209 Distributed configuration with ET200M 6,0$7,&5)56,0$7,&5)56,0$7,&5)76,0$7,&5)72WKHUPRGXOHVIURPWKH6UDQJHLQFOXGLQJ$60$60FKDQQHO5HDGHUZLWK56LQWHUIDFH5HDGHU5HDGHU7UDQVSRQGHU7UDQVSRQGHU$60b(70 Figure 7-34  Configurator for ASM 475 with RF310R reader (distributed configuration) Reader connection system &DEOHZLWKHQGVOHHYHVJUD\SLQN\HOORZEURZQZKLWHVKLHOG&DEOHVKLHOGH[SRVHG$60VLGH 5HDGHUVLGHJUHHQ6/*FRQQHFWRU6RFNHW0SLQ*7(ZLWKVWUDLJKW6/*FRQQHFWRUVWDQGDUG Figure 7-35  Installation of connecting cable between ASM 475 and RF300 reader with RS 422
Communication modules   7.6 ASM 475  SIMATIC RF300 210 System Manual, 06/2008, A5E01642529-02 Cable installation  Signal  Pin on  M12 connector Cable  Labeling 24 V DC  1  white  1 Reader 2 8 -16 TX -  2  brown  1 Reader 2 7-15 GND  3  Green  1 Reader 2 9-17 TX +  4  Yellow  1 Reader 2 6-14 RX +  5  Gray  1 Reader 2 4-12 RX -  6  Pink  1 Reader 2 5-13      Shielding  8 + terminal piece -   Cable assignment for connection of an RF300 reader to ASM 475
 Communication modules  7.6 ASM 475 SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  211 7.6.4 Technical data Table 7-19  Technical data for ASM 475   ASM 475 with FC 45 Serial interface for SIMATIC S7-300 or  ET200M I/O bus; cyclic and acyclic services Communication  2 words cyclic/238 bytes acyclic Command buffer in ASM 475  70 x 238 bytes per RF310R reader Serial interface to the reader   Connector  Via screw-type terminal on front connector The front connector is not included in the scope of supply. Max. cable length  Pre-assembled cables = 2 m, 5 m, (up to 1000 m on request) Readers that can be connected  2 x RF3xxR reader with RS422 parallel mode Software functions   Programming  Depending on the PROFIBUS DP master Function blocks for SIMATIC S7  FC 45 Transponder addressing  Access directly via addresses Commands  Initialize transponder, read data from transponder, write data to transponder Multitag mode  No S7 data structures via UDTs  Yes Power supply   Rated value  24 V DC Permissible range  20.4 V to 28.8 V DC Current consumption   Without reader for U = 24 V DC, max.  350 mA With reader connected, max.  500 mA, per connected reader Power dissipation of the module, typ.  2 Watts Current consumption from I/O bus, max.  80 mA Electrical isolation between S7-300 and RF300  Yes V24 fuse to reader  Yes, electronic Ambient temperature    During operation Horizontal installation of SIMATIC Vertical installation of SIMATIC  0 to +60 °C 0 to +40 °C Transport and storage  -40 up to +70 °C Dimensions (W x H x D) in mm  40 x 125 x 120 Weight, approx.  0,2 kg
Communication modules   7.6 ASM 475  SIMATIC RF300 212 System Manual, 06/2008, A5E01642529-02 7.6.5 Ordering data Table 7-20  Ordering data for ASM 475 and accessories Product description  Order No. ASM 475 interface module for SIMATIC S7  2 x RF3xxR reader with RS422 can be connected in parallel, without front connector 6GT2002-0GA10 Accessories:   Front connector (1 x per ASM)  6ES7392-1AJ00-0AA0 Connecting cable ASM 475 ↔ RF3xxR   Plug-in cable, pre-assembled, length: 2 m (standard length)  6GT2891-0EH20 Plug-in cable, pre-assembled, length: 5 m  6GT2891-0EH50 Terminal element (1 x per reader cable)  6ES7390-5BA00-0AA0 Shield connecting element  6ES7390-5AA00-0AA0 CD "RFID Systems Software & Documentation" with FC 45, S7 object manager 6GT2080-2AA10 FC 45 Reference Manual German English French  Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables.
 Communication modules  7.7 RF170C SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  213 7.7 RF170C 7.7.1 Description Area of application The RF170C communication module is a SIMATIC S7 module. It can be plugged into the ET 200pro distributed I/O device. The ET 200pro is operated by the user over PROFIBUS DP-V1 or PROFINET IO. An S7-300 or S7-400 with integrated PROFIBUS/PROFINET connection can be used as the controller.  The ET 200pro with RF170C can communicate with all DP masters compliant with the IEC 61784-1:2002 Ed1 CP 3/1 standard. The DP master must support DP-V1 (acyclic services). RF170C can be used as a central I/O in an ET 200pro with IM 154-8 CPU. Thanks to its degree of protection IP67, the RF170C can be installed and operated direct at the process without any additional protective housing.  Figure 7-36  RF170C communication module When operating the communication module on a SIMATIC S7, convenient function blocks are made available to the user. The following RFID systems can be operated with the RF170C: ● MOBY D ● MOBY U ● RF300 ● MOBY E ● MOBY I
Communication modules   7.7 RF170C  SIMATIC RF300 214 System Manual, 06/2008, A5E01642529-02 Features Operation of the RF170C requires an ET 200pro interface module (IM 154-1 DP, IM 154-2 DP High Feature, IM 154-4 PN High Feature, IM 154-8 CPU).  Via the RF170C: the data on the transponders can be ● physically addressed (normal addressing) or ● addressed by means of a DOS-like file management system (filehandler). Functions are available in SIMATIC S7 for both access methods: ● FC 45/FB 45 and FC 55 for normal addressing ● FC 56/FB 56 for filehandler The functions provide the S7 user with an interface with powerful commands that is easy to operate. In addition, the functions offer command chaining and S7 data structures via UDTs. The hardware of the RF170C is configured with an object manager (OM) integrated into the SIMATIC Manager, or with the GSD file. Other features ● Up to 9 RF170Cs can be operated simultaneously in one ET 200pro station. ● Any other I/O modules from the ET 200pro spectrum can be operated with the RF170C. ● Degree of protection IP67 ● Integration into the plant with standard cables or user-assembled cables using ECOFAST, M12, 7/8" or direct connection (heavy-gauge threaded joint) ● T functionality, that is, a component can be replaced without adversely affecting the bus communication and voltage supply of the other modules  ● Standardized PROFIBUS user interface for identification systems with RFID standard profile (available soon) ● Firmware update of the RF170C is – possible via PROFIBUS DP – possible via IM 154-8 CPU – not currently possible via PROFINET IO – not possible via GSD file ● Parameterizable diagnostics data ● Support for I&M functionality (I&M is a mechanism for reading out information via the module and saving system information such as function, installation date, installation location, and comments).
 Communication modules  7.7 RF170C SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  215 Design The ET 200pro is designed for rack mounting and always features  ● an interface module which transfers data to the DP master or IO controller, ● or a CPU, ● up to 9 RF170C modules, ● connection modules in various designs for – interface modules (PROFIBUS DP, PROFINET IO, power supply) – Communication modules You can thus set the focus of your configuration on local requirements. The comfortable handling features of ET 200pro ensure quick commissioning and easy maintenance.    Note A tool called SIMATIC ET 200 Configurator is available for configuring the ET 200pro. You will find the tool on the Internet at: http://www.siemens.com/automation/service&support Search for the entry with the number 22614936.
Communication modules   7.7 RF170C  SIMATIC RF300 216 System Manual, 06/2008, A5E01642529-02    Figure 7-37  ET 200pro with RF170C  ①  Rack ②  Interface module with bus module ③  RF170C communication module (comprising electronic module and bus module) ④  Terminating module ⑤  RF170C connection module ⑥  Connection module for interface module An IM 154-8 CPU can also be inserted as interface module.
 Communication modules  7.7 RF170C SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  217 Configuration   Note In the figures below, the ET 200pro with the CM IM DP Direct connection module represents an example for the interface module.   352),%86'3PDVWHUPRGXOHHJ6&38PVWDQGDUGFDEOHOHQJWK352),%86FDEOHWRDOO352),%86VODYHV9IRU5)&DQGUHDGHUZULWHUHDGGHYLFH,QWHUIDFHPRGXOHRIWKH(7SUR5HDGHUZULWHUHDGGHYLFH0'65)& Figure 7-38  Configurator for an RF170C  WR5)&:LWKDKLJKGDWDYROXPHWR5)&7KHWLPHVIRUFRPPDQGSURFHVVLQJPD\EHH[WHQGHG0D[LPXP5)&FDQEHRSHUDWHGLQDQ(7SUR Figure 7-39  Maximum configuration of RF170C on an ET 200pro
Communication modules   7.7 RF170C  SIMATIC RF300 218 System Manual, 06/2008, A5E01642529-02 7.7.2 Connect the RF170C with the connection module Introduction On the RF170C connection module, you connect the cable to the readers / write/read devices using 8-pin round sockets. Use an 8-pin M12 connector and a corresponding cable if you prefer to produce a customized cable. In doing so, please comply with the cable configurator in the system manuals of the RFID families.   Figure 7-40  Sockets and LEDs of the RF170C connection module Requirements Before you start to wire the RF170C connection module, switch off the supply voltage, or de-install the connection module.   Note It is easier to wire the RF170C connection module after you have removed it from the communication module.  Accessories required for the RF170C ● Patch cable with 8-pin M12 connector ● Alternatively: Shielded 7-core Cu cable, flexible, conductor cross-section ≤ 0.75 mm2 and 8-pin M12 connector Connecting M12 connectors  1. Plug the connector into the relevant socket of the RF170C connection module. Make sure the connector and socket are properly interlocked (groove and spring). 2. Tighten the knurled screws of the connector (torque = 1.5 Nm.)
 Communication modules  7.7 RF170C SIMATIC RF300 System Manual, 06/2008, A5E01642529-02  219 Connect RF170C connection module 1. Insert the RF170C connection module into the communication module. 2. Screw the connection module onto the rack (4 cross-head screws on the front: top and bottom, tightening torque 1.5 Nm)   Figure 7-41  Connect RF170C connection module Sealing unused sockets Always close all unused sockets using M12 caps in order to achieve the degree of protection IP65, IP66 or IP67.  Reference ET 200pro Distributed I/O device operating instructions, Section Electrical configuration of ET 200pro
Communication modules   7.7 RF170C  SIMATIC RF300 220 System Manual, 06/2008, A5E01642529-02 7.7.3 LED displays on the RF170C communication module LED display  The figure below shows the position and layout of the LED display on the the RF170C connection module.  Figure 7-42  LED display on the RF170C communication module Status and error LEDs on the RF170C connection module Table 7-21  Status and error LEDs for RF170C LEDs  Meaning* SF  Group errors  ACT_1, ACT_2  The corresponding reader / (write/read device) is active in processing a user command. (MOBY I only) ERR_1, ERR_2 *  A flashing pattern indicates the last error to occur. PRE_1, PRE_2 **  Indicates the presence of a transponder/MDS. RxD_1, RxD_2  Indicates live communication with the reader / write/read device. May also indicate malfunctions on the reader / write/read device. *  The meaning of the individual flashing pattern is described in the relevant FB and FC documentation. That documentation also includes the associated error descriptions. **  In the case of multitag operation, this LED uses a flashing interval to indicate the number of data carriers currently within the range of the reader / write/read device.