Siemens RF280R RFID Reader 13.56 MHz User Manual SIMATIC RF200

Siemens AG RFID Reader 13.56 MHz SIMATIC RF200

Contents

SYH_RF200_76_Part 3

Transponder   7.28 MDS D528  SIMATIC RF200 324 System Manual, 07/2017, J31069-D0227-U001-A9-7619
 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 325  System integration 8   The communication modules (interface modules) are links between the RFID components (reader and transponder) and the higher-level controllers (e.g. SIMATIC S7), or PCs or computers.  Interfacing to the controller The readers are connected to the controller via the following interface or communications modules: ● ASM 456 ● ASM 475 ● SIMATIC RF120C ● SIMATIC RF160C ● SIMATIC RF170C ● SIMATIC RF180C ● SIMATIC RF182C ● RFID 181EIP Function blocks, interface modules/communication modules and readers  Function blocks are used for integration into the SIMATIC. They are used to transfer the input parameters to the reader using the "init_run"(RESET) command. You will find information on the following blocks on the Internet in "Industry Online Support - RFID (https://support.industry.siemens.com/cs/ww/en/ps/15105/man)". ● FB 45 for MOBY U, MOBY D, RF200, RF300 ● FB 55 ● Ident profile and Ident blocks, standard function for RFID systems ● RFID standard profile; standard functions for RFID systems ● RF160C communications module with FC 44
System integration     SIMATIC RF200 326 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Interface modules/communication modules and function blocks The following table shows the most important features of the interface modules/communication modules, as well as the compatible function blocks. When assigning parameters (HW Config) to the communications and interface modules, MOBY U, MOBY D, RF200, RF300 or RF600 must be selected. Table 8- 1  Overview of interface modules/communication modules ASM/ communications module Interfaces to the application (PLC) Interfaces to the reader Reader con-nections Dimensions (W x H x D) Temperature range Type of protec-ton ASM 456 PROFIBUS DP-V1 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 54 or 79 mm 0 °C ... +55 °C IP67 ASM 475  S7-300 (cen-tral), ET200M (PROFIBUS) Via screw terminals in front connector 2  40 x 125 x 120 mm 0 °C ... +60 °C IP20 SIMATIC RF120C S7-1200 (cen-tral)  9-pin D-sub socket  1  30 x 100 x 75 mm 0 °C ... +55 °C IP20 SIMATIC RF160C PROFIBUS DP / DP-V0 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 30 mm 0 °C ... +55 °C IP67 SIMATIC RF170C PROFIBUS DP-V1 PROFINET IO 2 x 8-pin connector socket, M12 2 (parallel) 90 x 130 x 60 mm  -25 °C to +55 °C IP67 SIMATIC RF180C PROFINET IO 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 54 mm 0 °C to +60° C IP67 SIMATIC RF182C TCP/IP 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 30 mm 0 °C to +60 °C IP67 RFID 181EIP Ethernet IP 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 54 mm 0 °C to +60° C IP67 The following table shows the program blocks compatible with the interface modules/communications modules. Table 8- 2  Compatible program blocks ASM/ communications mod-ule Compatible program blocks in conjunction with ... S7-300 / S7-400 and STEP 7 Classic V5.5  S7-300 / S7-400 and STEP 7 Basic/Professional S7-1200 / S7-1500 and STEP 7 Basic/Professional ASM 456 FB 45 FB 55 Standard profile V1.19 Ident profile FB 45 FB 55 Ident profile Ident profile Ident blocks PIB_1200_UID_001KB PIB_1200_UID_032KB ASM 475 FB 45 FB 55 FB 45 FB 55 -- SIMATIC RF120C  --  --  Ident profile Ident blocks PIB_1200_UID_001KB PIB_1200_UID_032KB
 System integration  SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 327 ASM/ communications mod-ule Compatible program blocks in conjunction with ... S7-300 / S7-400 and STEP 7 Classic V5.5  S7-300 / S7-400 and STEP 7 Basic/Professional S7-1200 / S7-1500 and STEP 7 Basic/Professional SIMATIC RF160C FC 44 Application blocks for RF160C FC 44 Application blocks for RF160C Application blocks for RF160C SIMATIC RF170C FB 45 FB 55 FB 45 FB 55 -- SIMATIC RF180C FB 45 FB 55 Standard profile V1.19 Ident profile FB 45 FB 55 Ident profile Ident profile Ident blocks PIB_1200_UID_001KB PIB_1200_UID_032KB
System integration     SIMATIC RF200 328 System Manual, 07/2017, J31069-D0227-U001-A9-7619
 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 329  System diagnostics 9 9.1 Error codes of the RF200 readers   Note Validity of the error codes The following error codes apply only to RF200 readers with an S-422 interface (CM mode)  You can determine the error code in two ways: ● directly on the reader/CM by counting the flashing pattern of the red error LED ● via Ident profile with the "Status" output variable Give consideration to the form of the output variable in the following table ("0xE&FE$$00"; "&" = 1 ... 5; "$$" = error code). ● Through the FB45 variable "error_MOBY". Table 9- 1  Error codes of the RF200 readers Flashing of red LED on reader Error code (hexa- decimal) Description 00 00 no error 02 01 Presence error, possible causes: • The active command was not carried out completely • The transponder left the antenna field while the command was being processed - communication disruption between reader and transponder 05 05 Parameterization error, possible causes: • Unknown command • Incorrect parameter • Function not allowed 06 06 Air interface faulty 12 0C The transponder memory cannot be written, possible cause: Hardware fault (memory faulty) 13 0D Error in the specified memory address (access attempted to non-existent or non-accessible memory areas). 19 13 Buffer overflow: Insufficient buffer available in the reader for saving the command 20 14 Major system fault (hardware fault) 21 15 Parameter assignment error: faulty parameter in RESET command
System diagnostics   9.1 Error codes of the RF200 readers  SIMATIC RF200 330 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Flashing of red LED on reader Error code (hexa- decimal) Description 24 18 Only a RESET command is permitted 25 19 Previous command is still active 28 1C Antenna is already switched off/Antenna is already switched on 30 1E Incorrect number of characters in frame    Note Error message when memory area is protected For transponders with a locked or protected memory area, different error messages can occur following a write command depending on the data carrier type, e.g. MDS D1xx (NXP), D3xx (Infineon), D4xx (Fujitsu): Error 01, 0C
 System diagnostics  9.2 Diagnostics functions - STEP 7 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 331 9.2 Diagnostics functions - STEP 7 Further information on RFID diagnostics options can be found in the following function manuals: ● Function manual Ident profile and Ident blocks (https://support.industry.siemens.com/cs/us/en/view/106368029) ● Function Manual FB 45 (https://support.industry.siemens.com/cs/ww/en/view/21738808) 9.2.1 Reader diagnostics with "Reader Status" (SLG Status) With this command you can query the status and diagnostics data of the reader. Attribute "0x81" (mode 01), corresponds to UDT 110  Name Type Possible Values (hexadecimal) Comment hardware char   4D  4E 31 32 33 34 41 Type of hardware = RF280R with RS232 = RF280R with RS422 = RF260R = RF210/220R = RF240R = RF250R = RF290R hardware_version word   01 00  00 10; 00 29; 00 2B; 00 2C HW version (reserved) = RF200 without RF280R  = RF280R loader_version word   00 ... FF 00 ... FF Bootstrap loader version: e.g. 3130 (=version 1.0) = Version (high byte) = Version (low byte) firmware char 00 ... FF FW version : 33 (ASCII : 3 = RF2x0R) firmware_version word   00 ... FF 00 ... FF Firmware version: e.g. 3130 (=version 1.0) = Version (high byte) = Version (low byte) driver char   31 32 33 Driver version 3964R = 3964R = ASCII = ASCII/ScanMode driver_version word   00 ... FF 00 ... FF Driver version: e.g. 3132 (=version 1.2) = Version (high byte) = Version (low byte) interface byte   01 02 Interface type = RS-422 = RS-232
System diagnostics   9.2 Diagnostics functions - STEP 7  SIMATIC RF200 332 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Name Type Possible Values (hexadecimal) Comment baud byte   01 03 05 Transmission speed = 19.2 kBd = 57.6 kBd = 115.2 kBd multitag_SLG byte    01 Number of transponders (multitag/bulk) that can be processed in the antenna field = Single tag mode  field_ON_time_SLG byte 01  ISO transponder (non-specific)  status_ant byte   01 02 Status of the antenna = Antenna is on = antenna is off MDS_control  byte   00 01 Presence check = Operation without presence check = Operation with presence check (antenna is acti-vated.)    Note Completeness of the table Be aware that unassigned fields in the UDT are not listed here.
 System diagnostics  9.2 Diagnostics functions - STEP 7 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 333 9.2.2 Transponder diagnostics with "Tag Status" (MDS Status) The command can be used to scan the status data of the transponder that is located within the antenna field.  Attribute "0x83" (mode 03), corresponds to UDT 230  Name Type Possible Values (hexadecimal) Comment UID array[1…8] byte   000000000 0000000 ... FFFFFFFF FFFFFFFF Unique identifier =8 byte UID, MSB first MDS_type byte -- Transponder type (chip vendor, designation): 01 = ISO 15693 general 03 = ISO 15693 (Infineon, MDS D3xx) 04 = ISO 15693 (Fujitsu - 2 KB, MDS D4xx);  ISO 15693 (Fujitsu - 8 KB, MDS D5xx) 1) 05 = ISO 15693 (NXP, MDS D1xx) 06 = ISO 15693 (TI, MDS D2xx) 07 = ISO 15693 (STM, MDS D261) IC_version byte 0 ... FF Chip version  size word 0 ... FF Memory size in bytes  Depending on transponder type, e.g. MDS D3xx: 992 bytes lock_state byte 0 ... FF –not used with RF200 block_size byte 0 ... FF Block size of the transponder  for each transponder type, e.g. MDS D3xx: 4 bytes nr_of_blocks byte 0 ... FF Number of blocks  Depending on transponder type, e.g. MDS D3xx: 248 bytes  1) Except for RF280R; possible value (hexadecimal) 08
System diagnostics   9.2 Diagnostics functions - STEP 7  SIMATIC RF200 334 System Manual, 07/2017, J31069-D0227-U001-A9-7619
 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 335  Appendix A A.1 Certificates & approvals All the latest RFID radio approvals are available on the Internet (http://www.siemens.com/rfid-approvals).  Labeling Description  Conformity acc. to the RED EU directive Notes on CE marking The following applies to the system described in this documentation:  The CE marking on a device indicates the corresponding approval: DIN ISO 9001 certificate  The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems). EQ-Net certificate no.: 1323-01 Country-specific approvals: Safety If the device has one of the following markings the corresponding approval has been obtained:  Labeling Description  Underwriters Laboratories (UL) per UL 60950 (I.T.E) or per UL 508 (IND.CONT.EQ)  Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950 (I.T.E) or C22.2 No. 142 (IND.CONT.EQ)  Underwriters Laboratories (UL) according to standard UL 60950, Re-port E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142 (IND.CONT.EQ)  UL recognition mark
Appendix   A.1 Certificates & approvals  SIMATIC RF200 336 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Labeling Description  Canadian Standard Association (CSA) acc. to standard C22.2. No. 60950 (LR 81690) or acc. to C22.2 No. 142 (LR 63533)  Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533)  This product meets the requirements of the AS/NZS 3548 Norm.  USA (FCC) This device complies with Part 15 of the FCC Rules. FCC ID: NXW-RF... Canada (IC) Canada (IC) This device complies with Industry Canada licence-exempt RSS standard(s). IC: 267X-RF...  Russia, Belarus and Kazakhstan  Brazil (ANATEL) ANATEL-ID: XXXX-YY-ZZZZ) Mexico (COFETEL) Mexico (COFETEL)  South Africa (ICASA) China (CMIIT) China (CMIIT) CMIIT ID: XXXXYYZZZZ  South Korea (KCC)  Japan (VCCI)
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 337 A.2 Accessories A.2.1 Antenna splitter Area of application   Antenna splitter Characteristics   Area of application Designed for distributed mounting of antennas in warehouses, logistics and distribution Readers that can be connect-ed  RF290R Number of connectable  antennas max. 4  (by cascading) Connectable antennas • ANT D5 • ANT D6 • ANT D10 Degree of protection  IP65  The antenna splitter is a power distributor with electrical isolation between the input (IN) and the two outputs (OUT1, OUT2). At the operating frequency of 13.56 MHz, the impedance at all inputs and outputs is 50 ohms.  The device is used to connect 2 to 4 antennas to a reader. Gate, C and tunnel arrangements are therefore possible (see section "Configuration options"). Ordering data  Table A- 1  Ordering data for the antenna splitter  Article number Antenna splitter (incl. one antenna connecting cable 3.3 m) 6GT2690-0AC00  Table A- 2  Ordering data - accessories - antenna splitter  Article number Antenna cable  Length 3.3 m 6GT2691-0CH33 Length 10.5 m 6GT2691-0CN10 Antenna cable extension Length 7.2 m 6GT2691-0DH72
Appendix   A.2 Accessories  SIMATIC RF200 338 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Technical specifications  Table A- 3  Technical specifications for antenna splitter Technical specifications max. Input power 10 W Transmission frequency 13.56 MHz Power supply None Housing dimensions (L x W x H) 160 x 80 x 40 mm (without connector) Color Anthracite Material Plastic PA 12 Connector (inputs and outputs) TNC connector Securing 2 x M5 screws Ambient temperature • During operation • During transportation and storage  • -25 ℃ ... +65 ℃ • -25 ℃ ... +75 ℃ MTBF 3.0 x 10 5 hours Degree of protection according to EN 60529 IP65 (UL: for indoor use only) Shock resistant according to EN 60721-3-7 Class 7M2 Total shock response spectrum Type II 30 g Vibration according to EN 60721-3-7 Class 7M2  1 g (9 ... 200 Hz) / 1.5 g (200 ... 500 Hz) Weight, approx. 400 g Approval CE UL
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 339 A.2.2 Antenna multiplexer SIMATIC RF260X A.2.2.1 Characteristics The SIMATIC RF260X antenna multiplexer can be used to operate up to six antennas on one reader.  SIMATIC RF260X  antenna multiplexer Characteristics  Area of application Designed for distributed mounting of antennas in warehouses, logistics and distribution Readers that can be connect-ed  RF290R Number of antennas that can be connected maximum of 6  Connectable antennas • ANT D5 • ANT D6 • ANT D10 Degree of protection  IP65  A.2.2.2 Ordering data Table A- 4  SIMATIC RF260X ordering data  Article number SIMATIC RF260X Antenna multiplexer incl. antenna connecting cable 0.4 m 6GT2894-0EA00  Table A- 5  SIMATIC RF260X accessories ordering data  Article number 24 V connecting cable, 5 m 6GT2491-1HH50 RF290R 6GT2821-0AC12 Wide-range power supply unit for SIMATIC RF-systems  (100 - 240 V AC / 24 V DC / 3 A)  with 2 m connecting cable with country-specific plug EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 RS-232 connecting cable, with 4-pin M12 connector for 24 V for connection to the wide-range power supply unit, 5 m 6GT2891-4KH50 ANT D5 incl. antenna connecting cable (3.3 m) 6GT2698-5AA10 ANT D6 incl. antenna connecting cable (3.3 m) 6GT2698-5AB00 ANT D10 incl. antenna connecting cable (3.3 m) 6GT2698-5AF00
Appendix   A.2 Accessories  SIMATIC RF200 340 System Manual, 07/2017, J31069-D0227-U001-A9-7619  Article number Antenna cable  3.3 m 6GT2691-0CH33 10.5 m 6GT2691-0CN10 Antenna cable extension 7.2 m 6GT2691-0DH72 A.2.2.3 Description   ① 24 V DC power supply ② Antenna connections OUT 1 to OUT 6  with LEDs Color Status LED Yellow Lit when the corresponding antenna output is active. ③ SLG antenna connection "IN" ③ LEDs LED Color Status LED COMM / ERR Red • Flashes when the RF260X receives a signal from the SLG. (Only with commands directly to the RF260X) • Lit when the multiplexer has detected an error on the output (e.g. non-terminated antenna cable / defective antenna cable / short-circuit) HF - ON Green Lit when an HF signal is applied to the "IN" socket ③ RUN Green Flashes when the RF260X is in the normal operat-ing state. A.2.2.4 Principle of operation You can operate up to six antennas on one reader by using the multiplexer RF260X. The data is processed sequentially. Antenna switchover is performed in time-multiplex mode, so by connecting several antennas together, the processing time / activation time per antenna is lengthened accordingly.
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 341 A.2.2.5 Connectors ● Power supply  Pin Pin, casing side 4-pin M12 Assignment RF260X  1 Ground (0 V) 2 + 24 V 3 + 24 V 4  Ground (0 V)  ● Reader connector ③  Figure A-1  Reader connector If a longer antenna cable is required between the RF290R and SIMATIC RF260X multiplexer, a 7.2 m long cable (e.g. 6GT2691-0DH72) must be used to extend it, see Ordering data (Page 339).  The excess length must then be rolled up bifilar and fastened to minimize interference from external sources. ● Antenna outputs ② (OUT 1 to OUT 3 / OUT 4 to OUT 6)
Appendix   A.2 Accessories  SIMATIC RF200 342 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.2.6 Configuration  Figure A-2  Configuration example with ANT D5 A.2.2.7 Parameterization Parameter settings can be performed using the tool "RF290R-Set" (V9.5.2). This tool is primarily used for parameterization and commissioning, and is not designed for productive operation. The relevant parameters of the RF260X can be set in the "Configuration" menu under "SystemParameters > CFG15: Antenna Multiplexing" ①
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 343  Figure A-3  Menu "Configuration" MOBYDSet" ● For operation with RF260X, you need to activate the "Multiplexing" function ②. ● The number of occupied channels must be specified under "Number of Output Channels" ②. ● In "Multiplexer Valid Times" ③, the maximum time available for the antenna to read a transponder is entered. Following this time, the device switches to the next antenna automatically. If the read was successful, the time may be significantly shorter than specified here.   Note Changing the parameter assignment • Note that if you change the parameter settings of the reader or the RF260X in scanner mode, this may lead to frame collisions. These collisions result when the frame is sent while a transponder is present. • The "Transponder response time" (setting: "CFG2: COM interface") during operation of the RF260X must be higher than the total delay time for all the connected antennas (CFG15: MUX-VALD-TIME × Number of Output Channels ≤ Transponder Response Time)
Appendix   A.2 Accessories  SIMATIC RF200 344 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.2.8 RF260X commands Using the tool "RF290R-Set" (V9.5.2), certain commands can also be sent to the RF260X. In the "Commands" menu under "RF260X", the following commands can be sent: ● Detect (detection of the RF260X by the reader) ● Channel Select (set to a static channel) ● CPU-Reset (restart the RF260X software) ● Software Version (read out software and hardware versions)  Figure A-4  Sending commands from the "RF290R-Set" tool
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 345 A.2.2.9 Technical specifications  Technical specifications  Max. write/read distance ANT ↔ Transponder (Sg) See manual for the relevant antenna  Number of channels • Input channels • Output channels  • 1 • 6 Impedance 50 ohm Power supply 24 V (± 10 %) Current consumption max. 200 mA Dimensions (L x W x H) 240 x 150 x 70 mm Length of the connecting cable 0.4 m Color Anthracite Material Aluminum die-casting Plug-in connections • Power supply: Four-pole M12 / 4 pole round connector • Reader antenna connector: Single-pole TNC socket • Antenna connections: 6 x TNC socket Max. power (reader input, or per antenna) 8 W Shock resistant according to EN 60721-3-7 Class 7M2 Total shock response spectrum Type II 1.5 g Vibration according to EN 60721-3-7 Class 7M2 1.5 g (5 to 500 Hz) Securing 4 M5 screws Tightening torque  (at room temperature) ≤ 5 Nm Ambient temperature • During operation • During transportation and storage  • -20 ℃ ... +55 ℃ • -25 ℃ ... +70 ℃ MTBF 2.5 x 10 6 hours Degree of protection according to EN 60529  IP65 Weight, approx. 1.8 kg Approvals CE / FCC / IC
Appendix   A.2 Accessories  SIMATIC RF200 346 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.2.10 Dimensional drawing  Figure A-5  RF260X dimension drawing
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 347 A.2.3 Wide-range power supply unit for SIMATIC RF systems A.2.3.1 Features  Wide-range power supply unit for SIMATIC RF systems      ① DC output 1 ② DC output 2 ③ Network connector Characteristics • Wide-range input ③ for use worldwide • Dimensions without mains cable: 175 x 85 x 35 mm • Dimensions including mains cable: 250 x 85 x 35 mm • CE-compliant (EU and UK versions) • UL-certified for US and Canada (US version) • Mechanically and electrically rugged design • Secondary side ①, ②: 24 VDC / 3 A • Short-circuit and no-load stability • Suitable for frame mounting • 3 versions for use in the EU, UK, US Description The wide-range power supply unit for SIMATIC RF systems is a universal compact power supply and provides the user with an efficient, cost-saving solution for many different mid-range power supply tasks.  The primary switched power supply is designed for use on single-phase AC systems. The two DC outputs (sockets) are connected in parallel and protected by a built-in current limiting circuit against overload and short-circuits. The device is vacuum-cast and prepared for Safety Class 2 applications. The EU and UK versions satisfy the low-voltage guideline as well as the current EU standards for CE conformity. Furthermore, the US version has been UL-certified for the US and Canada.
Appendix   A.2 Accessories  SIMATIC RF200 348 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.3.2 Scope of supply ● Wide-range power supply unit for SIMATIC RF systems ● 2 m mains cable (country-specific) ● Protective cover for flange outlet ● Operating Instructions A.2.3.3 Ordering data Table A- 6  Ordering data for wide-range power supply unit  Article number Wide-range power supply unit for SIMATIC RF systems (100 - 240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-specific plug EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 24 V-connecting cable, length 5 m  6GT2491-1HH50 A.2.3.4 Safety Information   WARNING Danger to life It is not permitted to open the device or to modify the device. The following must also be taken into account: • Failure to observe this requirement shall constitute a revocation of the CE approval, UL certification for the US and Canada as well as the manufacturer's warranty. • For installation of the power supply, compliance with the DIN/VDE requirements or the country-specific regulations is essential. • The field of application of the power supply unit is limited to "Information technology equipment" within the scope of validity of the EN 60950/VDE 0805 standard. • When the equipment is installed, it must be ensured that the mains socket outlet is freely accessible. • The housing can reach a temperature of +25 °C during operation without any adverse consequences. It must, however, be ensured that the power supply is covered in the case of a housing temperature of more than +25°C to protect persons from contact with the hot housing. Adequate ventilation of the power supply must be maintained under these conditions.   NOTICE Area of application of the wide-range power supply unit The wide-range power supply unit may only be used for SIMATIC products in the specifically described area of application and for the documented purpose.
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 349 If the wide-range power supply unit for SIMATIC RF systems is used for an end product other than one from the SIMATIC RF family, the following must be taken into account: ● The electric strength test of the end product is to be based upon a maximum working voltage of: Transition from primary to SELV: 353 VDC, 620 Vpk ● The following secondary output circuits are SELV (low voltage; SELV = Safety Extra Low Voltage): all ● The following secondary output circuits are at non-hazardous energy levels: all ● The power supply terminals and/or connectors are suitable for field wiring if terminals are provided. ● The maximum investigated branch circuit rating is: 20 A ● The investigated pollution degree is: 2   WARNING Liability If the wide-range power supply unit for SIMATIC RF systems is connected to an end product other than one from the SIMATIC RF family, the end user is responsible and liable for operation of the system or end product that includes the wide-range power supply unit for SIMATIC RF systems.   NOTICE Restriction to the approval of the wide-range power supply The SIMATIC RF290R reader may only be operated with power supplies that have received KETI approval. There is currently no KETI approval for the wide-range power supply (6GT2898-0AAx0), which is why it may not be operated in South Korea. To be able to operate the SIMATIC RF290 reader in South Korea, use only a power unit that meets the following requirements: 230 VAC, 24 VDC / 3 A; KC safety approved  A.2.3.5 Connecting ● There are three different (country-specific) mains cables for the EU, UK and US. The appropriate mains cable must be connected to the primary input of the power supply.    Note It is only permissible to insert or remove the mains cable when the power supply is de-energized.  ● The wide-range power supply unit has total insulation (Safety Class 2), IP65 ● It can be mounted using four fixing holes.
Appendix   A.2 Accessories  SIMATIC RF200 350 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.3.6 Technical specifications  General technical specifications Insulation stability (prim./sec.) Uins p/s  3.3 kVAC Insulation resistance Rins  >1 GΩ Leakage current Ileak  Uin = 230 VAC, f = 50 Hz < 200 µA Safety class (SELV) Designed for installation in devices of Safety Class 2 Mains buffering th Uin = 230 VAC ≥ 50 ms Ambient temperature  -25 ℃ ... +55 ℃ Surface temperature Module top, center max. 96 ℃ Storage temperature  -40 ℃ ... +85 ℃ Self-heating on full-load  max. 45 K Interference immunity ESD HF fields Burst Surge HF injection Mains quality test EN 61000-4-2,  4-3 to 4-6, 4-11  Air discharge: 15 kV 10 V/m symmetrical: 2 symmetrical: 1 10 Vrms Cooling  Free convection Dimensions L x W x H  175 mm x 85 mm x 35 mm Weight  720 g Housing / casting  UL 94-V0 Power supply class according to CSA Level 3 Degree of protection  IP65   MTBF in years    255   Technical specifications - input Rated input voltage Uin  EN 60950 / UL 60950 100 to 240 VAC 120 to 353 VDC Input frequency fin  50/60 Hz Radio interference level  EN 55011/B Switching frequency fsw  approx. 70 kHz typ. Length of cable  2 m   Technical specifications - output Output voltage tolerance ∆Uout Uin = 230 VAC Uout nom ≤ +2 %/-1 % Overvoltage protection  Uout nom +20 % typ. Noise ∆ULF Uin = min., BW: 1 MHz ≤ 1 % Uout Noise ∆UHF Uin = min., BW: 20 MHz ≤ 2 % Uout
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 351 Technical specifications - output Regulation • Line regulation • Load regulation  • Uin = min./max. • Iout = 10...90...10 %  • ≤ 1,0 % • ≤ 1,0 % Short-circuit current Imax Inom = 4 A (+50 °C) 105 ... 130 % Inom Settling time tR load variations Iout = 10 ... 90 ... 10 % < 5 ms Temperature coefficient ε TA = -25 °C to +70 °C 0.01 %/K Overload behavior Pover  Constant current Short-circuit protection/ No-load response  Continuous/no-load stability Derating TA > +50 °C to +70 °C max. 2 %/K Connector type    M12, 4-pin; two sockets   Technical specifications - initial configurations Input Outputs U1 = U2 ILoad = I1 + I2 Efficiency (%) Remarks 110 VAC 24 VDC 0 A  No-load stability 110 VAC 24 VDC 3 A ≥ 88  220 VAC 24 VDC 0 A  No-load stability 220 VAC 24 VDC 3 A ≥ 90    Technical specifications - standards complied with Designation Standard Values Electrical safety EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition Conducted interference  EN 61000-6-3 EN 55011 Class B Emission  EN 61000-6-3 EN 55011 Class B All values are measured at full-load and at an ambient temperature of +25 ℃ (unless specified otherwise).
Appendix   A.2 Accessories  SIMATIC RF200 352 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.3.7 Pin assignment of DC outputs and mains connection Table A- 7   Pin assignment for DC outputs  Assignment     (1) Ground (0V) (2) +24 V DC (3) +24 V DC (4) Ground (0V)
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 353 Table A- 8  Pin assignment mains connector  Assignment     (1) 100 to 240 V AC (2) n.c. (3) 100 to 240 V AC (4) n.c. A.2.3.8 Dimension drawing  Figure A-6  Dimension drawing wide-range power supply unit for SIMATIC RF systems (all dimensions in mm)
Appendix   A.2 Accessories  SIMATIC RF200 354 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.2.3.9 Certificates and approvals Table A- 9  Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA00 - Europe, 6GT2898-0AA10 - UK Certificate  Description     CE approval to  2004/108/EC EMC 73/23/EEC LVD  Table A- 10 Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA20 - USA Standard    This product is UL-certified for the US and Canada. It meets the following safety standards: UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equip-ment UL Report E 205089
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 355 A.2.4 Transponder holders Table A- 11 Overview of the transponder holders and spacers Product photo Usable transponders Characteristics  6GT2190-0AA00 • MDS D100 • MDS D200 • MDS D400 • Spacer for mounting on metal, in conjunction with the fixing pocket 6GT2190-0AB00 • Distance from transponder to metal: 25 mm • Mounting: 4 x M4 screws • Material: PA6 • Weight: 31 g • Dimensions (L x W x H): 110 x 62 x 24 mm  6GT2190-0AB00 • MDS D100 • MDS D200 • MDS D400 • Fixing pocket in conjunction with spacer 6GT2190-0AA00 • Mounting: – Locks into spacer – 2 x screws/nails – Stapled • Material: PA6 • Weight: 12 g • Dimensions (L x W x H): 121 x 57 x 5 mm  6GT2390-0AA00 • MDS D100 • MDS D200 • MDS D400 • Fixing pocket not suitable for mounting directly on metal • Mounting: 2 x M4 countersunk screws • Material: PA6 • Weight: 21 g • Dimensions (L x W x H): 110 x 65 x 5 mm  6GT2690-0AA00 • MDS D139 • MDS D339 • Spacer for mounting on metal • Distance from transponder to metal: 30 mm • Mounting: 1 x M5 stainless steel screw • Tightening torque: 1.5 Nm • Material: PPS • Weight: 50 g • Dimensions (Ø x H): 85 x 30 mm
Appendix   A.2 Accessories  SIMATIC RF200 356 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Product photo Usable transponders Characteristics  6GT2690-0AH00 • MDS D139 • MDS D339 • Quick change holder for mounting on metal • Distance from transponder to metal: 30 mm • Mounting: Screw-in • Material: Stainless steel VA • Weight: 80 g • Dimensions (Ø x H): 22 x 60 mm  6GT2690-0AH10 • MDS D139 • MDS D339 • Quick change holder for mounting on metal • Distance from transponder to metal: 30 mm • Mounting: Screw-in • Material: Stainless steel VA • Weight: 60 g • Dimensions (Ø x H): 22 x 47 mm  6GT2690-0AK00 • MDS D124 • MDS D324 • MDS D424 • MDS D524 • Spacer for mounting on metal • Distance from transponder to metal: 15 mm • Mounting: 1 x M4 countersunk screw • Tightening torque: ≤ 1 Nm • Material: PPS • Weight: Approx. 4 g • Remounting cycles: at least 10 • Dimensions (Ø x H): 36 x 22 mm  6GT2690-0AL00 • MDS D126 • MDS D426 • MDS D526 • Spacer for mounting on metal • Distance from transponder to metal: 25 mm • Mounting: 1 x M4 countersunk screw • Tightening torque: ≤ 1 Nm • Material: PA6 • Weight: Approx. 12 g • Remounting cycles: at least 10 • Dimensions (Ø x H): 59 x 30 mm
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 357 Product photo Usable transponders Characteristics  6GT2690-0AG00 • MDS D160 • MDS D460 • Spacer for mounting on metal • Distance from transponder to metal: 10 mm • Mounting: 1 x M3 countersunk screw • Material: PA6 • Weight: 2 g • Dimensions (Ø x H): 20 x 14 mm Dimensional drawings  Figure A-7  Dimension drawing of spacer 6GT2190-0AA00 with fixing pocket 6GT2190-0AB00
Appendix   A.2 Accessories  SIMATIC RF200 358 System Manual, 07/2017, J31069-D0227-U001-A9-7619  Figure A-8  Dimension drawing of fixing pocket 6GT2390-0AA00  Figure A-9  Dimension drawing of spacer 6GT2690-0AA00
 Appendix  A.2 Accessories SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 359  Figure A-10 Dimension drawing of quick change holder 6GT2690-0AH00  Figure A-11 Dimension drawing of quick change holder 6GT2690-0AH10
Appendix   A.2 Accessories  SIMATIC RF200 360 System Manual, 07/2017, J31069-D0227-U001-A9-7619  Figure A-12 Dimension drawing of spacer 6GT2690-0AK00  Figure A-13  Dimension drawing of spacer 6GT2690-0AL00  Figure A-14 Dimension drawing of spacer 6GT2690-0AG00
 Appendix  A.3 Connecting cable SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 361 A.3 Connecting cable A.3.1 Reader RF2xxR (RS-422) with ASM 456 / RF160C / RF170C / RF180C / RF182C Connecting cable with straight connector  Figure A-15 Connecting cable between ASM 456, RF160C, RF170C, RF180C, RF182C and reader RF2xxR (RS-422) Table A- 12 Ordering data Length L Article number 2 m 6GT2891-4FH20 5 m 6GT2891-4FH50 10 m 6GT2891-4FN10 20 m 6GT2891-4FN20 50 m 6GT2891-4FN50
Appendix   A.3 Connecting cable  SIMATIC RF200 362 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Connecting cable with angled connector  Figure A-16 Connecting cable between ASM 456, RF160C, RF170C, RF180C and RF2xxR reader (RS-422) with angled connector Table A- 13 Ordering data Length L Article number 2 m 6GT2891-4JH20 5 m 6GT2891-4JH50 10 m 6GT2891-4JN10 The angled connector has a height of h = 29 mm and a length of l = 38 mm. Remember that due to the construction, the distance between the edge of the connector and the edge of the reader housing (H) is higher.  Figure A-17 Distance between connector edge and housing edge The distance between the edge of the connector and the edge of the reader housing (H) is as follows: RF210R/RF220R = 33 mm, RF240R/RF260R = 36 mm and RF290R = 37 mm. If you look at the reader from below, the angled connector points 90° to the right. With the RF290R reader the angle is approximately 135°.
 Appendix  A.3 Connecting cable SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 363 A.3.2 Reader RF2xxR (RS-422) with ASM 475 Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-4F… plug-in cables.   Figure A-18 Connecting cable between the ASM 475 and RF2xx reader (RS-422) Table A- 14 Ordering data Length L Article number 2 m 6GT2891-4EH20 5 m 6GT2891-4EH50
Appendix   A.3 Connecting cable  SIMATIC RF200 364 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.3.3 Reader RF2xxR (RS-422) with RF120C  Figure A-19 Connecting cable between RF120C and RF2xxR reader (RS-422) Table A- 15 Ordering data Length L Article number 2 m 6GT2091-4LH20  5 m 6GT2091-4LH50  10 m 6GT2091-4LN10    A.3.4 Reader RF240R/RF260R/RF290R (RS232) with PC The connecting cables have a length of 5 m. The outgoing cable for the power supply has a length of 0.5 m.
 Appendix  A.3 Connecting cable SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 365 With 4-pin power supply connector  Figure A-20 Connecting cable between PC and RF240R/RF260R/RF290R (RS-232) with 4-pin power supply connector Suitable power supply unit: e.g. wide-range power supply unit  With open ends for the power supply  Figure A-21 Connecting cable between PC and RF240R/RF260R/RF290R (RS-232) with open ends for the power supply Table A- 16 Ordering data connecting cable  Article number Connecting cable RS-232 with M12 male connector (4-pin), 5 m 6GT2891-4KH50 Connecting cable RS-232 with open ends (5 m) 6GT2891-4KH50-0AX0
Appendix   A.3 Connecting cable  SIMATIC RF200 366 System Manual, 07/2017, J31069-D0227-U001-A9-7619 A.3.5 Reader RF290R Antenna connecting cable  Figure A-22 ANT cable ↔ ANT Dx (3.3 m / 10.5 m) Table A- 17 Ordering data Length L Article number 3.3 m 6GT2691-0CH33 10.5 m 6GT2691-0CN10 Antenna extension cable  Figure A-23 Antenna extension cable (7.2 m)  Table A- 18 Ordering data Length L Article number 7.2 m 6GT2691-0DH72
 Appendix  A.4 Ordering data SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 367 A.4 Ordering data RF200 components  Table A- 19 RF200 reader  Readers Description Article number RF210R • With RS-422 interface (3964R) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x Ø): 83 x 18 mm • with integrated antenna 6GT2821-1AC10 RF210M • With RS-422 interface (3964R) • IP54 • Operating temperature: -20 °C ... +50 °C • Dimensions with handle (L x W x H) 195 x 26 x 140 mm • with integrated antenna 6GT2823-0AA00 RF220R • With RS-422 interface (3964R) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x Ø): 83 x 30 mm • with integrated antenna 6GT2821-2AC10 RF240R • With RS-422 interface (3964R) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 50 x 50 x 30 mm • with integrated antenna 6GT2821-4AC10 RF240R • With RS-232 interface (3964R) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 50 x 50 x 30 mm • with integrated antenna 6GT2821-4AC11 RF240R • With RS-232 interface (ASCII) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 50 x 50 x 30 mm • with integrated antenna 6GT2821-4AC40
Appendix   A.4 Ordering data  SIMATIC RF200 368 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Readers Description Article number RF250R • With RS-422 interface (3964R) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 50 x 50 x 30 mm • Reader with connections for external antennas ANT 8, ANT 12, ANT 18, ANT 30 6GT2821-5AC10 RF250R • With RS-232 interface (ASCII) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 50 x 50 x 30 mm • Reader with connections for external antennas ANT 8, ANT 12, ANT 18, ANT 30 6GT2821-5AC40 RF260R • With RS-422 interface (3964R) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna 6GT2821-6AC10 RF260R • With RS-232 interface (3964R) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna 6GT2821-6AC11 RF260R • With RS-232 interface (ASCII) • IP67 • Operating temperature: -20 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna 6GT2821-6AC40 RF280R • With RS-422 interface (3964R) • IP67 • Operating temperature: -25 … +70 °C • Dimensions (L x W x H): 160 x 80 x 41 mm • with integrated antenna 6GT2821-8AC10 RF280R • With RS-232 interface (ASCII) • IP67 • Operating temperature: -25 … +70 °C • Dimensions (L x W x H): 160 x 80 x 41 mm • with integrated antenna 6GT2821-8AC40
 Appendix  A.4 Ordering data SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 369 Readers Description Article number RF290R • With RS-232 interface (Advanced protocol) and  RS-422 interface (3964R) • IP65 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 200 x 140 x 80 mm • Long-range reader with the option of connecting external antennas ANT D5, ANT D6, ANT D10 6GT2821-0AC12 RF310M • IP65 • Operating temperature: -20 °C ... +50 °C • Dimensions (L x W x H): 277 x 100 x 44 mm • Mobile reader with integrated antenna 6GT2803-1AC00 RF310M • IP65 • Operating temperature: -20 °C ... +50 °C • Dimensions (L x W x H): 277 x 100 x 44 mm • Mobile reader with connections for external antennas ANT 8, ANT 12, ANT 18, ANT 30 6GT2803-1AC10  Table A- 20 ISO transponder ISO transponder Description Article number MDS D100 • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +80 °C • Dimensions (L x W x H): 85.6 x 54 x 0.9 mm • Credit card format 6GT2600-0AD10 MDS D117 • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 4 x 5 mm 6GT2600-0AG00  MDS D124 • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +180 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm 6GT2600-0AC10 MDS D126 • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole 6GT2600-0AE00
Appendix   A.4 Ordering data  SIMATIC RF200 370 System Manual, 07/2017, J31069-D0227-U001-A9-7619 ISO transponder Description Article number MDS D127 • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +125 °C • Dimensions (Ø x H): M6 x 5 (±0.2) mm 6GT2600-0AF00 MDS D139 • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: up to +200 °C / +220 °C • Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm 6GT2600-0AA10 MDS D160 • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C...+70 °C • Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm • Laundry tag for cyclic applications 6GT2600-0AB10 MDS D165 • IP65 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W): 86 x 54 mm • Smartlabel (PET) in credit card format 6GT2600-1AB00-0AX0 MDS D200 • IP67 • Memory size: 256 bytes of EEPROM user memory • Operating temperature: -20 °C ... +60 °C • Dimensions (L x W x H): 86 x 54 x 0.8 mm • Credit card format 6GT2600-1AD00-0AX0 MDS D261 • IP65 • Memory size: 256 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W): 55 x 55 mm • Smartlabel (PET), small design 6GT2600-1AA00-0AX0 MDS D324 • IP67; IPx9K • Memory size: 992 bytes of EEPROM user memory • Operating temperature: -25 °C ... +125 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm 6GT2600-3AC00 MDS D339 • IP68; IPx9K • Memory size: 992 bytes of EEPROM user memory • Operating temperature: -25 °C ... +220 °C • Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm 6GT2600-3AA10
 Appendix  A.4 Ordering data SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 371 ISO transponder Description Article number MDS D400 • IP67 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +60 °C • Dimensions (L x W x H) 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm 6GT2600-4AD00 MDS D421 • IP67; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature –25 °C ... +85 °C • Dimensions (Ø x H): 10 x 4.5 mm 6GT2600-4AE00 MDS D422 • IP68 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): M20 x 6 (±0.2) mm • Can be screwed into metal (flush-mounted) 6GT2600-4AF00 MDS D423 • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 30 (+0.2/-0.5) x 8 (-0.5) mm 6GT2600-4AA00 MDS D424 • IP67; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +125 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm 6GT2600-4AC00 MDS D425 • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 24 X 10 mm; M6 thread • Screw transponder 6GT2600-4AG00 MDS D426 • IP68 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole 6GT2600-4AH00 MDS D428 • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8 6GT2600-4AK00-0AX0
Appendix   A.4 Ordering data  SIMATIC RF200 372 System Manual, 07/2017, J31069-D0227-U001-A9-7619 ISO transponder Description Article number MDS D460 • IP67; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm 6GT2600-4AB00 MDS D521 • IP67; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature –25 °C ... +85 °C • Dimensions (Ø x H): 10 x 4.5 mm 6GT2600-5AE00 MDS D522 • IP68 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): M20 x 6 (±0.2) mm • Can be screwed into metal (flush-mounted) 6GT2600-5AF00 MDS D522 Special variants • IP68 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 18 (+0.1) x 5.2 mm • Can be clipped into metal (flush-mounted) 6GT2600-5AF00-0AX0 MDS D524 • IP67 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm 6GT2600-5AC00 MDS D526 • IP67; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole 6GT2600-4AH00 MDS D528 • IP68; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8 6GT2600-5AK00
 Appendix  A.4 Ordering data SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 373 Table A- 21 Communication modules/interface modules  ASM/ communications module Description Article number ASM 456 ASM 456 for PROFIBUS DP-V1 max. 2 readers connectable 6GT2002-0ED00 ASM 475  ASM 475 for SIMATIC S7 max. 2 RF2xxR readers with RS-422 can be connected in parallel without a front connector 6GT2002-0GA10 RF120C Communications module RF120C for SIMATIC S7-1200 6GT2002-0LA00 RF160C Communications module RF160C for PROFIBUS DP V0 max. 2 readers connectable 6GT2002-0EF00 RF170C RF170C communications module 6GT2002-0HD00 RF170C connecting block 6GT2002-1HD00 RF180C RF180C communications module  max. 2 SLGs or readers can be connected 6GT2002-0JD00 Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin)  6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00 RF182C RF182C communication module  Max. 2 SLGs or readers can be connected 6GT2002-0JD10 Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin)  6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00 RFID 181EIP RF182C communications module  max. 2 SLGs or readers can be connected 6GT2002-0JD20 Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin)  6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00  Table A- 22 Antennas  Antennas Description Article number ANT 3 • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 50 x 28 x 10 mm • without antenna connecting cable 6GT2398-1CD30-0AX0 • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CD40-0AX0 ANT 8 • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M8 x 40 mm • without antenna connecting cable 6GT2398-1CF00 • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CF10
Appendix   A.4 Ordering data  SIMATIC RF200 374 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas Description Article number ANT 12 • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M12 x 40 mm • incl. one integrated antenna connecting cable 0.6 m 6GT2398-1CC10 • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CC00 ANT 18 • IP67 (front) • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M18 x 55 mm • incl. one integrated antenna connecting cable 0.6 m 6GT2398-1CA10 • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CA00 ANT 30 • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M30 x 58 mm • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CD00 ANT D5 • IP65 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 380 x 380 x 110 mm • incl. one antenna connecting cable 3.3 m 6GT2698-5AA10 ANT D6 • IP65 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 580 x 480 x 110 mm • incl. one antenna connecting cable 3.3 m 6GT2698-5AB00 ANT D10 • IP65 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 1150 x 365 x 115 mm • incl. one antenna connecting cable 3.3 m 6GT2698-5AF00 Accessories Table A- 23 Reader accessories Readers Accessories  Article number RF290R Adapter for mounting on a DIN rail  (pack of 3) 6GK5798-8ML00-0AB3
 Appendix  A.4 Ordering data SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 375 Table A- 24 ISO transponder accessories Transponder Accessories  Article number MDS D100 / D200 / D400 Spacer 6GT2190-0AA00 Fixing pocket 6GT2190-0AB00 Securing pocket  (cannot be mounted directly on metal) 6GT2390-0AA00 MDS D139 / D339 Spacer (Ø x H): 85 x 30 mm 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 48 mm 6GT2690-0AH00 MDS D124 / D324 / D424 / D524 Spacer (Ø x H): 35 x 15 mm 6GT2690-0AK00 MDS D126 / D426 / D526 Spacer (Ø x H): 60 x 30 mm 6GT2690-0AL00 MDS D160 / D460 Spacer (Ø x H): 20 x 15 mm 6GT2690-0AG00  Table A- 25 Antenna accessories Antennas Accessories  Article number ANT 3 / ANT 8 Antenna connecting cable  with M8 plug (with angled plug) 6GT2391-0AH30 ANT D5 / ANT D6 / ANT D10 Antenna splitter (incl. one antenna connecting cable 3.3 m) 6GT2690-0AC00 Antenna multiplexer SIMATIC RF260X (incl. one antenna connecting cable 0.4 m) 6GT2894-0EA00 Antenna cable 3.3 m 6GT2691-0CH33 10.5 m 6GT2691-0CN10 Antenna cable extension 7.2 m 6GT2691-0DH72 ANT D6 Cover 6GT2690-0AD00  Table A- 26 Accessories - connecting cable RF200 reader ↔ PC Connecting cable Accessories Article number RF240R / RF260R / RF290R (RS-232) and PC Connecting cable RS-232  with M12 male connector (4-pin), 5 m 6GT2891-4KH50 Connecting cable RS-232  with open ends, 5 m 6GT2891-4KH50-0AX0 RF290R Antenna cable 3.3 m 6GT2691-0CH33 Antenna cable 10.5 m 6GT2691-0CN10 RF290R Antenna extension cable 7.2 m 6GT2691-0DH72
Appendix   A.4 Ordering data  SIMATIC RF200 376 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Table A- 27 Accessories - connecting cable communications module/ASM ↔ reader Connecting cables Description Length Article number ASM 456 / RF160C / RF170C / RF180C  and RF2xxR reader (RS-422) 2 m 6GT2891-4FH20 5 m 6GT2891-4FH50 10 m 6GT2891-4FN10 20 m 6GT2891-4FN20 50 m 6GT2891-4FN50 ASM 456 / RF160C / RF170C / RF180C   and RF2xxR reader (RS-422) with angled connector 2 m 6GT2891-4JH20 5 m 6GT2891-4JH50 10 m 6GT2891-4JN10 ASM 475 and RF2xxR reader (RS-422) 2 m 6GT2891-4EH20 5 m 6GT2891-4EH50 RF120C and reader RF3xxR (RS-422) 2 m 6GT2091-4LH20  5 m 6GT2091-4LH50  10 m 6GT2091-4LN10   Table A- 28 RFID accessories, general RFID general Article number DVD "Ident Systems Software & Documentation" 6GT2080-2AA20 Wide-range power supply unit for SIMATIC RF systems  (100 - 240 VAC / 24 VDC / 3 A)  with country-specific power cable/plug, 2 m EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 24 V connecting cable, 5 m 6GT2491-1HH50 M12 connector, 4-pin for wide range power supply unit, pack of 3 6GK1907-0DB10-6AA3
 Appendix  A.5 Service & Support SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 377 A.5 Service & Support Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link 1: (https://support.industry.siemens.com/cs/de/en/)  Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc. ● Contacts, Technical Forum ● The option submitting a support query: link 2: (https://support.industry.siemens.com/My/ww/en/requests) ● Our service offer: Right across our products and systems, we provide numerous services that support you in every phase of the life of your machine or system - from planning and implementation to commissioning, through to maintenance and modernization. You will find contact data on the Internet at the following address: Link 3: (http://w3.siemens.com/aspa_app) RFID homepage For general information about our identification systems, visit RFID homepage (http://w3.siemens.com/mcms/identification-systems/). Online catalog and ordering system  The online catalog and the online ordering system can also be found on the Industry Mall Homepage (https://mall.industry.siemens.com). SITRAIN - Training for Industry The training offer includes more than 300 courses on basic topics, extended knowledge and special knowledge as well as advanced training for individual sectors - available at more than 130 locations. Courses can also be organized individually and held locally at your location. You will find detailed information on the training curriculum and how to contact our customer consultants at the following Internet address: Link: (http://sitrain.automation.siemens.com/sitrainworld/)
Appendix   A.5 Service & Support  SIMATIC RF200 378 System Manual, 07/2017, J31069-D0227-U001-A9-7619
 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 379  Index   A Accessories SIMATIC RF260X antenna multiplexer, 339 Wide-range power supply unit, 347 ANT 12 Definition of distance D, 179 ANT 18 Definition of distance D, 184 ANT 30 Definition of distance D, 190 ANT 8 Definition of distance D, 174 ANT D10 Definition of distance D, 206 Dimensions, 208 Transmission window, 204 ANT D5 Definition of distance D, 195 ANT D6 Definition of distance D, 200 Antenna ANT 1, 161 ANT 12, 177 ANT 18, 182 ANT 3, 166 ANT 30, 187 ANT 8, 172 ANT D10, 203 ANT D5, 192 ANT D6, 198 Antenna splitter, 337 Technical specifications, 338 Application Planning SIMATIC RF200, 27 Approvals, 335 Article numbers, 367 ASM 475 Assignment for connecting cable, 363 Pin assignment, 363 C Certificates, 335 Communication time Calculating, 37 D Detection area, 34 Diagnostic functions ISO transponder, 333 Direction of motion Transponder, 34 Dwell time Transponder, 36 Dynamic mode, 35 Dwell time of the transponder, 36 F Field data RF210R, 39 RF220R, 40 RF240R, 40 RF260R, 44 RF280R, 45 RF290R, 46 Flush-mounting of transponders and readers, 52 I Input parameters, 325 Installation Several readers, 53 Installation guidelines, 50 ISO transponder Resistance to chemicals, 93 M MDS D100 transponder Technical specifications, 212 MDS D117 transponder Technical specifications, 216 MDS D124 Transponder Technical specifications, 220 MDS D127 transponder Technical specifications, 230 MDS D160 transponder Technical specifications, 240
Index   SIMATIC RF200 380 System Manual, 07/2017, J31069-D0227-U001-A9-7619 MDS D200 transponder Technical specifications, 248 MDS D339 transponder Technical specifications, 260 MDS D424 Transponder Technical specifications, 283 MDS D425 Transponder Technical specifications, 286 MDS D428 transponder Technical specifications, 293 MDS D460 Transponder Technical specifications, 297 MDS D521 transponder Technical specifications, 301 MDS D522 transponder Technical specifications, 305 MDS D524 transponder Technical specifications, 314 MDS D526 transponder Technical specifications, 318 MDS D528 transponder Technical specifications, 321 Metal Influence on the transmission window, 54 Metal-free space Reader RF280R, 74 Reader RF290R, 76 RF210R reader, 55 RF220R reader, 58 RF240R reader, 60 RF250R reader, 63 RF260R reader, 71 Minimum distance Antenna to antenna, 50 Reader to reader, 50 Transponder to transponder, 48 O Ordering data, 367 Accessories, 374 Antenna multiplexer SIMATIC RF260X, 339 Antenna splitter, 337 Antennas, 373 Interface modules/communication Modules, 373 ISO transponder, 369 Readers, 367 Wide-range power supply unit, 348 P Parameter assignment Function blocks, 325 R Reader RF280R Metal-free space, 74 Reader RF290R Metal-free space, 76 Reader SIMATIC RF210M, 110 Reader SIMATIC RF240R, 122 Reader SIMATIC RF280R, 140 Reader SIMATIC RF290R, 147 Readers Mounting, 53 Reducing interference due to metal, 51 Resistance to chemicals Transponder, 93 RF200 transponder Resistance to chemicals, 93 RF210R reader Metal-free space, 55 RF220R reader Metal-free space, 58 RF240R reader Metal-free space, 60 RF250R reader Metal-free space, 63 RF260R reader Metal-free space, 71 S Selection criteria SIMATIC RF200 components, 27 SIMATIC RF210R reader, 104 SIMATIC RF220R reader, 116 SIMATIC RF250R reader, 128 SIMATIC RF260R reader, 134 SIMATIC RF260X, 339 SIMATIC RF260X antenna multiplexer, 339 Static mode, 35 Dwell time of the transponder, 36 Support, 377 T Technical specifications MDS D100 transponder, 212
 Index  SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 381 MDS D117 transponder, 216 MDS D124 Transponder, 220 MDS D127 transponder, 230 MDS D160 transponder, 240 MDS D200 transponder, 248 MDS D339 transponder, 260 MDS D424 Transponder, 283 MDS D425 Transponder, 286 MDS D428 transponder, 293 MDS D460 Transponder, 297 MDS D521 transponder, 301 MDS D522 transponder, 305 MDS D524 transponder, 314 MDS D526 transponder, 318 MDS D528 transponder, 321 Transponder MDS D126, 226 Transponder MDS D139, 235 Transponder MDS D165, 244 Transponder MDS D261, 251 Transponder MDS D324, 255 Transponder MDS D400, 266 Transponder MDS D421, 272 Transponder MDS D422, 275 Transponder MDS D423, 279 Transponder MDS D426, 290 Tracking Tolerance, 30 Tracking tolerances, 30 Training, 377 Transmission gaps, 38 Transmission window Impact of metal, 54 Width, 30 Transponder Detection area, 34 Directions of motion, 34 Dwell time, 36 Mounting on metal, 53 Transponder MDS D126 Technical specifications, 226 Transponder MDS D139 Technical specifications, 235 Transponder MDS D165 Technical specifications, 244 Transponder MDS D261 Technical specifications, 251 Transponder MDS D324 Technical specifications, 255 Transponder MDS D400 Technical specifications, 266 Transponder MDS D421 Technical specifications, 272 Transponder MDS D422 Technical specifications, 275 Transponder MDS D423 Technical specifications, 279 Transponder MDS D426 Technical specifications, 290 U User data calculating, 37 W Wide-range power supply unit, 347 Pin assignment for DC outputs, 352
Index   SIMATIC RF200 382 System Manual, 07/2017, J31069-D0227-U001-A9-7619

Navigation menu