Siemens MOBYI-SLG42N Tag Reader System User Manual Innentitel

Siemens AG Tag Reader System Innentitel

Contents

Users Manual Part 2

5-21MOBY I Configuration, Installation and Service Manual(4) J31069-D0033-U001-A8.1-76185.6 SLG 42The SLG 42 is a middle-of-the-line read/write device.  With its larger an-tenna, the SLG 42 generates a much larger field than the SLG 41, and agreater range can be achieved with the same data memories.  In dynamic op-eration, larger amounts of data can be read from and written to the MDS.See chapter 3.4.Figure 5-23 SLG 42 read/write deviceTable 5-14 Ordering data for SLG 42Read/write device SLG 42up to 70 mm (medium power)SLG plug connector and stub lines6GT2 001-0BA00See chapter 3.10Table 5-15 Technical data of SLG 42Inductive interface to MDSData transmission speedRead/write distanceSLG to MDS (max.)Transmission frequencyPowerData19200 baud70 mm (see field data table)134 kHz1.81 MHzSerial interface to ASM 6-pin SLG plug connector in acc. w. DIN 43651Transmission speed 19200 baud, RS 422Line length, ASM to SLG (max.) at 24 V DC 120 mSupply voltage (via serial interface)Nominal value 24 V DCPermissible range 20 to 30 V DCCurrent consumptionIdle/operation 60 mA/180 mAMTBF 2 x 106Application areaOrdering dataTechnical dataRead/Write Devices
5-22MOBY I Configuration, Installation and Service Manual(4) J31069-D0033-U001-A8.1-7618Table 5-15 Technical data of SLG 42HousingDimensions in mm (W x H x D) 75 x 40 x 75Color GrayMaterial Polyamide 12Plug connection DIN 43651Protection ratingShockVibrationIP6550 g20 gMounting of SLGTurning moment (at room temperature)4 M5 screws 2 NmAmbient temperatureDuring operationDuring transportation and storage–25° to +70° C–40° to +85° CWeight (approx.) 250 gSilicon free YesThe exact field data depend on the type of MDS used.Table 5-16 Field data of SLG 42Operating distance (Sa)0 to 55 mmLimit distance (Sg)70 mmMedian deviation (L) Depends on MDSMinimum distance from SLG to SLG (D) > 800 mmMade in GermanySIEMENS MOBY I SLG 42THIS DEVICE COMPLIES WITH PART 15 OF THE  FCC RULES. OPERATION IS SUBJECT TOTHE FOLLOWING TWO CONDITIONS:(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUSTACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE CautionField dataFCC informationRead/Write DevicesUNDESIRED OPERATION.Any changes or modifications not expressly approved by the partyresponsible for compliance could void the user's authority to operate theequipment.
5-23MOBY I Configuration, Installation and Service Manual(4) J31069-D0033-U001-A8.1-7618MMLength of trans-mission win-dow (L)Transmissionwindow at ope-rating distanceFigure 5-24 Transmission window of SLG 42aaaaa = 30 mmMetal-free space withflush installationFigure 5-25 Metal-free space for SLG 42DDSLG 42SLG 42SLG 42Figure 5-26 Distance D:  SLG 42Transmission windowMetal-free spaceDefinition of distance DRead/Write Devices
5-24MOBY I Configuration, Installation and Service Manual(4) J31069-D0033-U001-A8.1-7618756555756405.5754925Figure 5-27 Dimensional diagram of SLG 42Dimensions(in mm)Read/Write Devices

Navigation menu