Contents

Users manual

5-15MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-76185.5 SLG 75The SLG 75 ANT is a read/write device in the middle of the performancerange. It can only be used with ANT 1, ANT 12, ANT 18 and ANT 30. Theantennas can be very easily positioned for any application.The cable between the antenna and evaluation unit is 3 m long. The lengthcannot be changed. The antenna cable can be connected on the SLG side.The SLG 75 can be used with the following interface modules: ASM 400, ASM 410, ASM 424, ASM 450, ASM 452, ASM 454, ASM 470,ASM 473 und ASM 475.Figure 5-16 Read/write device SLG 75ANT 1Figure 5-17 ANT 1 for SLG 75The ANT 1 is an antenna in the middle of the performance range which isvery useful in production plants and assembly lines because of its easily han-dled housing.The antenna’s dimensions make it possible to read/write large volumes ofdata from/to the MDS during operation. The antenna cable can be connectedon the SLG side.Applicationarea SLG 75Areas ofapplicationof the antennasRead/Write Devices – Read/Write Antennas
5-16 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618ANT 12Figure 5-18 ANT 12 for the SLG 75The ANT12 is intended primarily for tool identification. The very small size ofthe antenna permits very accurate positioning using the plastic nuts includedwith it. The antenna cable can be connected on the SLG side. Data carrier com-munication is only possible with the MDS E623 (tool pill) in static mode.ANT 18Figure 5-19 ANT 18 for the SLG 75The ANT 18 was designed primarily for use in small assembly lines. The small,compact dimensions of the antenna with its two plastic nuts (included with theproduct) make it easy to position for any application. The antenna cable can beconnected on the SLG side. Data carrier communication is only possible withthe MDS E624 in static mode.ANT 30Figure 5-20 ANT 30 for the SLG 75The ANT 30 was designed primarily for use in small assembly lines. Themaximum read/write range is approximately 60% greater than the ANT 18.The compact dimensions of antenna with its two plastic nuts (included withthe product) make it very easy to position for any application. The antennacable can be connected on the SLG side. Data carrier communication is onlypossible with the MDS E624 in static mode.Read/Write Devices – Read/Write Antennas
5-17MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Table 5-11 Ordering data for the SLG 75 and ANT xxSLG 75 write/read devicewith RS 422 serial interfaceThe antenna is not included with theSLG 75 and must be ordered separately.6GT2 398-1AF00Antennas:ANT 1  75 x 75 x 20 (L x W x H)ANT 12 M12 x 1.0 x 40 (∅ x wght x L)ANT 18 M18 x 1.0 x 55 (∅ x wght x L)ANT 30 M30 x 1.5 x 58 (∅ x wght x L)6GT2 398-1CB006GT2 398-1CC006GT2 398-1CA006GT2 398-1CD00SLG connector and plug-in line See Section 3.7Table 5-12 Technical data of the SLG 75(read/write device) SLG 75Inductive interface to MDSANT-MDS read/write distances See field dataTransmission frequency 13.56 MHzSerial interface to ASM RS 422Data transmission speed 19200 BaudLine length (ASM - SLG), max.(for 24 VDC and a cross-section of0.2 mm2)120 mMax. data cable length.(See cable configuration in Table 3-13.) 1000 mMDS addressingcommand Direct access via addressesInitialize MDS, read data from MDS,write data to MDSSupply voltage (via serial interface)Nominal valuePermissible range 24 VDC 20 to 30 VDCCurrent consumptionSwitch-on current (brief)Operation (at 24 VDC) Max. of 700 mA180 mA (typical)MTBF (at +40° C) 2.5 x 105 hoursHousingDimensions (in mm)Electronics w/o connectors (L x W x H) 160 x 80 x 40ColorMaterialConnectorDataAnthracitePlastic (PA 12)6-pin SLG connector in accordance withDIN 43 651 (pin, device side)Ordering dataTechnical dataRead/Write Devices – Read/Write Antennas
5-18 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Table 5-12 Technical data of the SLG 75(read/write device) SLG 75Protection rating in accordance withEN 60 529Shock in accordance withEN 60 721-3-7/class 7M2Vibration in accordance withEN 60 721-3-7/class 7M2IP 6530 g11 g (3 to 200 Hz)11.5 g (200 to 500 Hz)1Mounting of SLGTightening torque at room temperature2 M5 screws3 NmAmbient temperatureDuring operationDuring transportation and storage –25 °C to + 70 °C–40 °C to + 85 °CWeight (approx.) 520 gCertification CE, UL/CSA, FCC1Warning: The values for shock and vibration are maximum values and mustnot occur continuously.Read/Write Devices – Read/Write Antennas
5-19MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Table 5-13 Technical data of the antennasAntenna ANT 1 ANT 12 ANT 18 ANT 30Write/read distance, max. ANT-MDS (Sg) 100 mm 5 mm 15 mm 24 mmHousing, dimensions in mm 75 x 75 x 20 (L x W x H) M12 x 1.0 x 40(∅ x wght x L) M18 x 1.0 x 55(∅ x wght x L) M30 x 1.5 x 58(∅ x wght x L)Color Anthracite Pastel turquoiseMaterial Plastic (PA 12) PlasticCrastinConnector 4-pinpin, antenna sideAntenna line length 3 mProtection rating in accordance withEN 60 529 IP 67 IP 67 (front)Shock in accordance withEN 60 721-3-7/class 7M2Vibration in accordance withEN 60 721-3-7/class 7M230 g 11 g (3 to 200Hz)11.5 g (200 to 500 Hz)1Mounting of antenna 2 M5 screws 2 plastic nutsM12 x 1.0 2 plastic nuts M18 x 1.0 2 plastic nuts M30 x 1.5Ambient temperatureDuring operationDuring transportation and storage–25 °C to +70 °C–40 °C to +85 °CMTBF (at +40 °C) 2.5 x 105 hoursWeight (approx.) 80 g 45 g 120 g 150 g1Warning: The values for shock and vibration are maximum values and must not occur continuously.Table 5-14 Field data of the SLG 75 with antennaSLG 75 ANT 1 ANT 12 ANT 18 ANT 30Working distance (Sa) 0 to 70 mm 0 to 4 mm 0 to 8 mm 0 to 18 mmLimit distance (Sg) 100 mm 5 mm 15 mm 24 mmDiameter of the transmission window(Ld)Depends onMDS 8 mm Depends onMDS 14 mmMinimum distance from SLG toSLG (D) 800 mm  80 mm  125 mm  200 mmField dataRead/Write Devices – Read/Write Antennas
5-20 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Transmission window:The antenna of the MDS must be positioned inside this field to ensure reliable data communication.SgSide viewTransmission window MDSTop viewSa1 The transmission window canbe larger at Sa, min.L (Sa,min)1L (Sa,max) = LdFigure 5-21 Transmission window of the ANT 1LdTop viewsgsaSide viewLdTransmission windowFigure 5-22 Transmission window of the ANT12TransmissionwindowRead/Write Devices – Read/Write Antennas
5-21MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618LdTop viewLdsgsaSide view 1 The transmission window canbe larger when Sa, minL (Sa, min)1Figure 5-23 Transmission window of the ANT18LdTop viewsgsaSide viewLdTransmission windowFigure 5-24 Transmission window of the ANT 30Read/Write Devices – Read/Write Antennas
5-22 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Metal-free space with flush mountinga = 40 mmaMetalaaah = 20 mm (non-metallic base)Figure 5-25 Metal-free space for the ANT 1Note:Flush installation in metal reduces the limit and working distance.Top view Side viewMOBYEANT 12Figure 5-26 Metal-free space for the ANT12aMOBY EANT 18a = 10 mmb = 10 mmMetal-free space with flushinstallationNote:The limit and working distances arereduced when the metal-free space isnot adhered to.1010ANT 18Figure 5-27 Metal-free space for the ANT 18Metal-free spaceRead/Write Devices – Read/Write Antennas
5-23MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618MOBYEANT 3020Side view2020Top viewFigure 5-28 Metal-free space for the ANT 30Made in GermanySIEMENS MOBY E SLG 75FCC ID: NXWMOBYE-SLG75THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TOTHE FOLLOWING TWO CONDITIONS:(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUSTACCEPTANYINTERFERENCERECEIVED; INCLUDING INTERFERENCE THATMAYCAUSENoteThe manufacturer is not responsible for any radio or TV interference causedby unauthorized modifications to this equipment:Such modifications could void the user’s authority to operate the equipment.FCC informationRead/Write Devices – Read/Write AntennasUNDESIRED OPERATION.
5-24 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618DaDbANT 1ANT 1ANT 1Da> 800 mmDb> 800 mmFigure 5-29 Distance D: ANT 1Da 80 mmDb 80 mmThe SLG electronics can bemounted directly next to each other.DbDaFigure 5-30 Distance D: ANT 12Da 125 mmDb 125 mmThe SLG electronics can bemounted directly next to each other.DbDaFigure 5-31 Distance D: ANT 18Definition ofthe distance DRead/Write Devices – Read/Write Antennas
5-25MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-7618Da 200 mmDb 200 mmThe SLG electronics can bemounted directly next to each other.DbDaFigure 5-32 Distance D: ANT 30Read/Write Devices – Read/Write Antennas
5-26 MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-76185.55580 4016025Figure 5-33 Dimensioned drawing of SLG 755 2075Minimum bendingradius: 20 mmCable length 3 mANT 1 can be connected on electronics sideFigure 5-34 Dimensioned drawing of the ANT 140M12Fine threadGradient 1.0Minimum bendingradius: 20 mmCable length 3 mANT 12 can be connected on electronics sideAntennaheadAntennasideSide viewof the antennahead17MOBY EANT 12Figure 5-35 Dimensioned drawing of the ANT 12Dimensions (in mm)Read/Write Devices – Read/Write Antennas
5-27MOBY E Configuration, Installation and Service Manual(4) J31069-D0105-U001-A5-761855M18Fine threadGradient 1.0Minimum bendingradius: 20 mmCable length 3 mANT 18 can be connected on electronics sideAntennaheadAntennasideSide viewof the antennahead24MOBY EANT 18Figure 5-36 Dimensioned drawing of the ANT 1858M30Fine threadincline: 1.5Minimum bendingradius: 20 mmCable length 3 mANT 30 can be connected on electronics sideAntennaheadAntennasideSide viewof the antennahead43MOBY EANT 30Figure 5-37 Dimensioned drawing of the ANT 30NoteThe length of the line between antenna and evaluation unit is 3 m. Thelength cannot be changed.CautionThe antenna must not be removed in an energized state.Read/Write Devices – Read/Write Antennas