Shure orporated ULXD6X52 Wireless Boundary Transmitter User Manual v02

Shure Incorporated Wireless Boundary Transmitter v02

User Manual v02

Le Guide de l’UtilisateurGuia del UsuarioGuida dell’UtenteРуководство пользователяBedienungsanleitung日本語繁體中文Manual do Usuário사용자 가이드Panduan Pengguna用戶指南Gebruikershandleiding
WARNING: Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The safety certifications do not apply when the operating voltage is changed from the factory setting.This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.IMPORTANT SAFETY INSTRUCTIONS1.  READ these instructions. 2.  KEEP these instructions. 3.  HEED all warnings.4.  FOLLOW all instructions. 5.  DO NOT use this apparatus near water. 6.  CLEAN ONLY with dry cloth. 7.  DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions. 8.  DO NOT install near any heat sources such as open flames, radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not place any open flame sources on the product. 9.  DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10.  PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11.  ONLY USE attachments/accessories specified by the manufacturer.12.  USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.13.  UNPLUG this apparatus during lightning storms or when unused for long periods of time. 14.  REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15.  DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus. 16.  The MAINS plug or an appliance coupler shall remain readily operable. 17.  The airborne noise of the Apparatus does not exceed 70dB (A). 18.  Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection. 19.  To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 20.  Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.21.  Operate this product within its specified operating temperature range.
3Quick Start Instructionspowersync pushcontrolENTEREXITSCANRFA BOLOLgainaudiosync pushcontrolENTEREXITSCANRFA BOLOLgainaudioaabbbcULXD4Digital Wireless ReceiversyncENTEREXITSCANSB900baA150 mA45°linemiclinemiclinemiclinemiclinemiclinemiclinemiclinemiclinemiclinemiclinemiclinemica<15 cm (6 in.) RFA BOLOLgainaudioRX1sync1-G: 01CH:03     TxOn2-G: 01CH:06     TxOn3-G: 01CH:08     TxOn4-G: 01CH:12     TxOnSelect RX TO SCAN1 Receiver     2 Receiver     3 Receiver     CHANNEL SCANGROUP SCAN     GROUP SCAN             SCAN COMPLETEGROUP:01     OPEN FREQ:70      RX CHAN FOUND:  4     Deploy Completed    4 of 4    Channels Set      SYNC TX NOW EXITSCANEXITSCANEXITSCAN+ + +--+AAULXD4QDigital Wireless ReceiverIIIIIIIIIIIIIbac+--+AAENTEREXIT
4ULXD series boundary and gooseneck microphones and networked charging stations add new designs to Shure's breakthrough ULX-D wireless line. Boundary and gooseneck transmitters offer cable-free flexibility for corporate conference rooms, government facilities, and educational institutions. Use Shure Wireless Workbench® and networked charging stations to simplify transmitter configuration and monitor charging status. Simply change settings in Wireless Workbench for all transmitters docked on a charger, instead of syncing each transmitter individually.Both microphones run on rechargeable or AA batteries and can be controlled through external control systems, such as AMX or Crestron. As part of Shure's groundbreaking ULXD line, both gooseneck and boundary microphones include audio signal encryption, high-density mode, and the reliability of ULX-D systems. Boundary microphones offer cardioid and omnidirectional cartridges, and the gooseneck base fits Microflex series gooseneck microphones.Included Components•  AA BatteriesAccessories2-bay networked charger for gooseneck and boundary microphonesSBC2504-bay networked charger for gooseneck and boundary microphonesSBC4508-bay networked charger for gooseneck and boundary microphonesSBC8508-Bay Shure Battery Charger SBC8006' USB-A cable with wall plug for charging Wireless TransmittersSBC-USB-AModel VariationsULXD Cardioid Boundary MicrophoneULXD6/CULXD Omnidirectional Boundary MicrophoneULXD6/OULXD Gooseneck Base ULXD85" Cardioid Gooseneck MicrophoneMX405LP/C5" Supercardioid Gooseneck MicrophoneMX405LP/S10" Cardioid Gooseneck MicrophoneMX410LP/C10" Supercardioid Gooseneck MicrophoneMX410LP/S15" Cardioid Gooseneck MicrophoneMX415LP/C15" Supercardioid Gooseneck MicrophoneMX415LP/S5" Gooseneck with Red Top LED (no cartridge)MX405RLP/N10" Gooseneck with Red Top LED (no cartridge)MX410RLP/N15" Gooseneck with Red Top LED (no cartridge)MX415RLP/N10" Cardioid Dualflex Gooseneck MicrophoneMX410LPDF/C10" Supercardioid Dualflex Gooseneck MicrophoneMX410LPDF/S10" Dualflex Gooseneck with Red Top LED (no cartridge)MX410RLPDF/N10" Cardioid Dualflex Gooseneck Microphone with Red Top LEDMX410RLPDF/C10" Supercardioid Dualflex Gooseneck Microphone with Red Top LEDMX410RLPDF/S15" Cardioid Dualflex Gooseneck MicrophoneMX415LPDF/C15" Supercardioid Dualflex Gooseneck MicrophoneMX415LPDF/S15" Dualflex Gooseneck with Red Top LED (no cartridge)MX415RLPDF/N15" Cardioid Dualflex Gooseneck Microphone with Red Top LEDMX415RLPDF/C15" Supercardioid Dualflex Gooseneck Microphone with Red Top LEDMX415RLPDF/S
5௡௟௣ ௤௢௠௠௢௥௡௡Transmitter Controls and Connectors① Power ButtonPress and hold for two seconds to turn microphone on or off.② Mute/Active ButtonFour settings are available for the mute/active button: - Toggle: Press to switch between active and mute states - Push-to-Mute: Hold button to mute microphone - Push-to-Talk: Hold button to activate microphone when speaking - Disabled: Button functionality off③ Status LEDIndicates microphone's audio status.④ Low-Battery LED - Off = More than 30 minutes of battery life remain  - On = Less than 30 minutes of battery life remain⑤ Infrared (IR) PortAlign with receiver IR port to send settings to transmitter.⑥ Charge ConnectorConnects to networked chargers.⑦ Gooseneck MicrophoneULXD8 base fits 5", 10", and 15" Microflex series microphones.Status LEDTo change status LED behavior, use Wireless Workbench or ULXD receiver front panel.ULXD6 and ULXD8 (with MX400 series gooseneck)Active MutedGreen (factory setting)Red (factory setting)Red OffRed Flashing redULXD8 (with MX400R series gooseneck)Active MutedRed (factory setting) Off (factory setting)Red Flashing
6Battery and ChargingInstallation1.  Open the battery compartment.2.  Insert one SB900 battery or two AA batteries. Align +/- terminals on batteries as shown.3.  Close battery door until it latches. ++--++Battery InformationSee the receiver front panel or the microphone properties on Wireless Workbench for detailed battery information. ChargingCharge transmitters with Shure rechargeable batteries in networked charging station.Connecting Gooseneck Microphone to ULXD8 BaseULXD8 bases fit 5", 10", and 15" Microflex series gooseneck microphones. Connect microphone to base as shown.Changing Transmitter SettingsModify the transmitter's mute/active button behavior, status LED behavior, high-pass filter, and encryption settings to fit your setup. There are three different ways to change transmitter settings: 1.  Change settings in Wireless Workbench and send to all transmitters on a networked charger2.  Change settings in Wireless Workbench, send settings to each receiver, and perform an IR sync between each receiver and transmitter pair3.  Change settings for each transmitter from ULXD receiver front panel and perform an IR syncRFA B! ! ! ! ! !!!!!!!!!!!!!!! !! ! !!௔ ௕ ௖For configuration details, see the full manual available at www.shure.com.
7Frequency RangeBand Frequency Range (  MHz)G50 470 to 534G51 470 to 534G52 479 to 534H50 534 to 598H51 534 to 598H52 534 to 565H53 534 to 598J50 572 to 636J51 572 to 636K51 606 to 670K52 606 to 670L51 632 to 696L52 632 to 694L53 632 to 714P51 710 to 782P52 710 to 782JB (Tx only)806 to 810Q51 794 to 806S50 823 to 865X51 925 to 937.5X52 902 to 928X53 902 to 907.500, 915 to 928X54 915 to 928Z16 1240 to 1260CertificationsThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Certified under FCC Part 74, FCC Part 15. Certified by IC in Canada under RSS-247 and RSS-210,RSS-GEN. IC: 616A-ULXD6G50, 616A-ULXD6H50, 616A-ULXD6J50, 616A-ULXD6X52, 616A-ULXD8G50, 616A-ULXD8H50, 616A-ULXD8J50, 616A-ULXD8X52.FCC: DD4ULXD6G50, DD4ULXD6H50, DD4ULXD6J50, DD4ULXD6X52, DD4ULXD8G50, DD4ULXD8H50, DD4ULXD8J50, DD4ULXD8X52.This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking. Note: For transmitters operating in the V50 and V51 bands: nominal free space antenna gain at middle of the band is typically -6 dBi, and rolls off at the band edges an additional -4 dB.This device complies with Industry Canada licence-exempt RSS standard(s). Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance. The CE Declaration of Conformity can be obtained from: www.shure.com/europe/Global
8complianceAuthorized European representative:Shure Europe GmbHHeadquarters Europe, Middle East & AfricaDepartment: EMEA ApprovalJakob-Dieffenbacher-Str. 1275031 Eppingen, GermanyPhone: 49-7262-92 49 0Fax: 49-7262-92 49 11 4Email: info@shure.deInformation to the userThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and the receiver.•  Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.LICENSING INFORMATIONLicensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability depends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies. For the band Z17 (1492-1525 MHz), it must be used indoors only.For the band Z19 (1785-1800 MHz), if the transmitter operates on a frequency below 1790 MHz, it must be used indoors only.WARNING: Danger of explosion if battery incorrectly replaced. Operate only with Shure compatible batteries.WARNING•  Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat above 140°F (60°C), or incinerate.•  Follow instructions from manufacturer•  Only use Shure charger to recharge Shure rechargeable batteries•  WARNING: Danger of explosion if battery incorrectly replaced. Replace only with same or equivalent type.•  Never put batteries in mouth. If swallowed, contact your physician or local poison control center•  Do not short circuit; may cause burns or catch fire•  Do not charge or use battery packs other than Shure rechargeable batteries•  Dispose of battery packs properly. Check with local vendor for proper disposal of used battery packs.•  Batteries (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the likeWARNING: This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Please follow your regional recycling scheme for batteries, packaging, and electronic waste.

Navigation menu