Shure orporated PA821A Antenna Combiner User Manual Exhibit D Users Manual per 2 1033 c3

Shure Incorporated Antenna Combiner Exhibit D Users Manual per 2 1033 c3

Exhibit D Users Manual per 2 1033 c3

Model PA821A Antenna CombinerGuide de l’utilisateur du répartiteur d’antenne PSM®Bedienungsanleitung für die Antennenweiche PSM®Guía del usuario del combinador de antenas PSM®Guida d’uso del combinatore di antenne PSM®PSM® アンテナコンバイナ ユーザーガイドPSM® 天线合并器用户指南PSM® 天線合併器用戶指南PSM  ® Antenna Combiner 사용자 설명서27A15837(Rev. 1) Printed in U.S.A.©2011 Shure Incorporated N108PA821A  User Guide
3! IMPORTANT SAFETY INSTRUCTIONS !1. READ these instructions.2. KEEP these instructions.3. HEED all warnings.4. FOLLOW all instructions.5. DO NOT use this apparatus near water.6. CLEAN ONLY with dry cloth.7. DO NOT block any ventilation openings. Install in accordance with the manu-facturer's instructions. 8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampli ers) that produce heat.9. DO NOT defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not  t into your out-let, consult an electrician for replacement of the obsolete outlet.10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.11. ONLY USE attachments/accessories   by the manufacturer.12.13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.14. REFER all servicing to quali ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is dam-aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects  lled with liquids, such as vases, on the apparatus.16. The MAINS plug or an appliance coupler shall remain readily operable.17. The airborne noise of the apparatus does not exceed 70dB (A).18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.19. To reduce the risk of  re or electric shock, do not expose this apparatus to rain or moisture. 20. Do not attempt to modify this product.  Doing so could result in personal injury and/or product failure.USE only with a cart, stand, tripod, bracket, or table speci ed by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.DESCRIPTIONThe Shure PA821A Antenna Combiners actively combine antenna outputs from up to eight PSM wireless transmitters to a single antenna, improving RF performance and reducing rack clutter.INSTALLATIONSet the power switch on the front panel to OFF before installing. Connect the unit to an AC power source using the supplied power cable. Switch the power ON to use the device. The power light will illuminate. Power the unit OFF when not in use or before disconnecting the unit from the AC power source.8-TO-1 COMBINING:1.  Using the supplied BNC-BNC cables, connect the Antenna Output of each transmitter to the ANTENNA INPUTS of the PA821A (Figure 2).2.  Attach an antenna to the MAIN Out of PA821A. For wideband applications, use PA805SWB directional antenna (Figure 1).3.  Connect the PA821A to a power outlet using one of the supplied power cables. The PA821A contains a universal power supply to operate anywhere in the world.NOTE: When the PA821A is powered on, the input signal indicators (1-8)  on  the  front  panel  will  illuminate  if  an  active  transmitter  is  con-nected to the corresponding input (1-8) on the back panel (Figure 1).WARNING: Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to quali ed service personnel. The safety certi cations do not apply when the operating voltage is changed from the factory setting.WARNING: This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.PSM TransmittersAC  POWERFIGURE 2FIGURE 1
4FOR MORE THAN 8 TRANSMITTERS1.  Using the supplied BNC-BNC cables, connect the Antenna Output of each transmitter to the Antenna Inputs of the PA821A.2.  Use the 1 ft. jumper BNC-BNC cable to connect the MAIN Output of the PA821A to the  A IN of the Expansion Port. 3.  Connect another Antenna Output (from a ninth PSM transmitter, second PA821A or other antenna port) to the  B IN of the Expansion Port.4.  Attach an antenna to the A + B OUT of the Expansion Port. For wideband applications, use the PA805-SWB directional antenna, Figure 3.FIGURE 3FURNISHED ACCESSORIES(8) 2 ft. Coaxial Cable (RG58C/U) UA8021 ft. jumper 95J2035120 VAC Power Line Cord 95A8389230 VAC Power Line Cord 95A8247240 VAC Power Line Cord (U.K.) 95A8713OPTIONAL ACCESSORIESWideband Unidirectional Antenna (470-952 MHz) PA805SWB10 ft. Coaxial Cable (RG-8X/U) PA72525 ft. Coaxial Cable (RG-8X/U) UA82550 ft. Coaxial Cable (RG-8X/U) UA850AC PowerPSM Transmitters50Ω BNCLICENSINGChanges or modifications not expressly approved by Shure Incorporated could  void  your authority to  operate  the  equipment.  Licensing  of  Shure wireless microphone equipment is the user’s responsibility, and licensability depends on the user’s classification and application, and on the selected frequency.  Shure  strongly  urges  the  user  to  contact  the  appropriate telecommunications  authority  concerning  proper  licensing,  and  before choosing and ordering frequencies.THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFESSIONAL ENTERTAINMENT AND SIMILAR APPLICATIONS.NOTE  THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON SOME FREQUEN-CIES NOT AUTHORIZED IN YOUR REGION. PLEASE CONTACT YOUR NATIONAL AUTHORITY TO OBTAIN INFORMATION ON AUTHORIZED FRE-QUENCIES FOR WIRELESS MICROPHONE PRODUCTS IN YOUR REGION.Licensing: Note that a ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements.SPECIFICATIONSRF Carrier Frequency Range 470-952 MHzSystem Gain +0/-5 dBInput AC Line Voltage 100-240 Vac, 50/60 HzMaximum Input Line Power 70WMaximum Current Drain 0.42-1.5 Amperes(Amperes = 150 VA/Input AC Line Voltage)Maximum RF Input Power 24 dBm (250 mW) per channelInput Signal Indicator  Threshold +4 dBm (2.5 mW), +2 dBm (1.6 mW) typicalImpedance 50 Ω nominalOperating Temperature Range 0° F (-18° C) to +145° F (+63°  C)NOTE: Electrical safety approval is based on a maximum ambient temperature of 30°C.Overall Dimensions 43.4 mm high x 398.8 mm wide x331.5 mm deep (1 11/16 in. H x 15 11/16 in. W  x 13 1/2 in. D)Net Weight 4.53 Kg(10 lbs unpackaged, without power and  RF cables)Input/Output Connector Type BNC-type 8 input, 1 output ACTIVE2 inputs, 1 output  EXPANSION PORTCERTIFICATIONSPA821A: Certified to FCC Part 74 (FCC ID No. DD4PA821A). Certified in Canada by IC to RSS-123 AND RSS-102 (Certification No. IC: 616A-PA821A). UL LISTED to UL6500 (2nd Edition) and cUL LISTED to CAN/CSA E60065-00. Meets the Essential Requirements of the Eu-ropean R&TTE Directive 99/5/EC, eligible to bear CE mark. Meets EMC requirements of EN 301 489 Parts 1 and 9 and is GS-Certified to EN 60065 (6th Edition). Conforms to Australian EMC requirements, eligible to bear C-Tick mark (N108).150VA max
www.shure.com ©2010 Shure IncorporatedEurope, Middle East, Africa:Shure Europe GmbHWannenäckestr. 28,74078 Heilbronn, GermanyPhone: 49-7131-72140Fax: 49-7131-721414Email: info@shure.deAsia, Pacific:Shure Asia Limited22/F, 625 King’s RoadNorth Point, Island EastHong KongPhone: 852-2893-4290Fax: 852-2893-4055Email: info@shure.com.hkUnited States, Canada, Latin America, Caribbean:Shure Incorporated5800 West Touhy AvenueNiles, IL 60714-4608 USAPhone: 847-600-2000Fax: 847-600-1212 (USA)Fax: 847-600-6446Email: info@shure.com

Navigation menu