 WATER TRANSMITTER INSTALLATION GUIDE   The  following  information  contains  installation  instructions  for  the  Transmitter  Unit  (MXU).  The  wiring connections  are  the  same  for  both  inside  and  pit  set  installations.  Techniques  may  be  different  for  the actual MXU placement in each type of installation.  Recommended Tools and Materials •  SR II ® security screw socket with 1/4" nut driver or ratchet wrench •  3M Scotchlok ® UY-2 butt connector “gel-caps” •  3M Scotchlok ® E-9Y stepped jaw crimping tool with wire cutter •  Wire stripper tool •  Screwdrivers (Phillips and standard blade heads) •  Power drill and bit (1/4") •  8 x 1" sheet metal screws •  1/2" Electrical Metallic Tubing (EMT) •  Conduit cutting tool •  Hammer •  Conduit driver  •  Three-conductor solid wire   Wiring Diagram
 WIRING INSTRUCTIONS The MXU wiring instructions assume the utility meter with an encoder register has been installed and the proper  wire  has  been run  to  the  MXU  installation  location.  Three-conductor,  22  gauge,  solid  conductor cable  is  recommended.  (For  meter  installation,  refer  to  the  installation  information  included  in  meter shipping cartons.)  1.  Using  the  SR  II  security  socket  with  ratchet  wrench  or  nut  driver,  open  the  MXU  enclosure  by removing  SR  II type  security screw.  Bottom  part  of  enclosure  will contain  the  MXU  battery and  top part the  electronics and connection  wires. Connect  the three  wires  from the encoder register to the matching color  wires  on the MXU. If  not  already done, strip approximately  2"  off outer jacket of the encoder wire cable. The wire colors for each unit should be green, red, and black. Insert two matching color wire  ends  –  red to  red,  green  to  green,  and black  to  black into  a  UY-2 gel-cap  with the  color button  of  gel-cap  facing away.  (This  provides a better view of wire positions  inside the clear plastic gel-cap  enabling the  installer to  see  the  wires  are  completely and  properly inserted.) Using gel-cap pliers, squeeze the gel-cap. This will splice the two wires and release the waterproof gel to seal the connection. The splice can be checked by pulling gently on the gel-cap while holding the wires to be sure  they  are  tight  and  secure.  Repeat  for  the  remaining  two  wire  connections.  If  any  of  the  wire connections are not being used they should be capped at the end with a gel-cap. This is to prevent water intrusion via wicking through the exposed wire ends. 2.  Connect the battery to the MXU electronics. Using the gel-cap connecting technique described above, connect the red and white stripe wire from the battery to the red and white stripe wire from the MXU electronics. Repeat the procedure for the black and white stripe wire from the battery to the black and white stripe wire from the MXU. Caution: DO NOT cross connect the black and white and the red and white wires of the MXU and battery pack as this may cause damage to the MXU electronics. 3.  (Optional) TouchRead ® Connection – The MXU includes a built-in TouchRead splitter connection to allow  the  encoder  register  to  be  interrogated  by  both  the  MXU  and  a  remote  TouchRead  System sensor. Wall  Mount  TouchPad  –  Using  two-conductor  or  three-conductor  wire  cable  and  gel-caps,  connect wires to each of the green and white stripe wires from the MXU. Note: If three-conductor wire cable is used,  the  third  wire  is  not  utilized  for  the  TouchRead  Connection.  At  the  TouchPad  connection, connect the same two wires to the terminal screws on the back of the TouchPad. Caution: Be sure there  is  no bare  wire-to-wire  contact.  (The  TouchRead  connection  is  non-polarity  sensitive  and  will work as long as the same color wires are used at both ends of the connection. If three-conductor wire is used, be sure the third “dead” wire is not mistakenly connected at either end.) Pit-set Mount Sensor – The TouchRead pit-set sensor includes a factory-sealed three-conductor wire cable.  Proper  wire  connections  are  therefore  important.  To  activate  the  pit-set  TouchRead  sensor, use only the red and black wires from the sensor. Approximately 2" of the cable’s outer jacket must be stripped from its end to access these wires. Then, using gel-caps, connect the black wire from the sensor to one of the green and white stripe wires from the MXU. Next, connect the red wire from the sensor to the other green and white stripe wire from the MXU. 4.  Verify  MXU  operation  prior  to  final  assembly  -  To  verify  MXU  reading,  use  a  Handheld  Terminal (HHT) to interrogate the register and compare to the register odometer reading, register ID number, and  MXU  ID  number.  To  verify  TouchRead  reading,  use  a  TouchRead  visual  reader  to  display register  odometer  reading(s)  and  register  ID  number(s).  If  MXU  does  not  function,  check  all  wire connections, redo the connections or change battery pack. (For complete TouchRead installation and troubleshooting, see installation bulletins: TR-728, TR-997, and TR-998.) 5.  After wiring connections are completed and MXU operation is verified, align guides of top and bottom parts  of  MXU  and  close,  bringing  the  connection  wires  out  the  front  side,  using  the  wire  pass-thru guides located on either side of the security screw. Secure the top and bottom parts of the MXU using the security screw. Caution: DO NOT over-tighten security screw.
 MOUNTING INSTRUCTIONS Wall Mounting: (Indoors and Outdoors) 1.  Using MXU mounting bracket, find a convenient location for the MXU mounting. The MXU should be mounted  in  a  vertical  position  so  the  top  part  with  the  logo  is  facing  the  front.  The  MXU  mounting bracket can be mounted to a wall using screws or fastened to an object using heavy duty wire ties. Grooves  have  been  placed  in  the  back  of  the  bracket  for  mounting  on  either  horizontal  or  vertical (existing) pipes. 2.  After  mounting  the  MXU  bracket,  snap  the  MXU  (which  should  already  be  wired  as  noted  in  the preceding  wiring  instructions) into  the bracket.  Be sure  the  locating tabs  on either  side of  the  MXU have snapped into position in the mounting bracket.The installation is now complete. 3.  TouchPad  Mounting  (Optional)  –  If  mounting  the  MXU  outdoors  and  a  TouchRead  TouchPad connection  is  to  be  included,  mounting  holes  can  be  drilled  in  the  side  of  the  MXU  bracket.  Using short screws or plastic rivets, mount the TouchPad to the side of the MXU bracket. Caution: When using screws, be sure they do not penetrate the MXU enclosure when mounting the TouchPad. The TouchPad  can  also  be  mounted  in  a  location away  from  the MXU.  Be  sure to  use  screws  that  are designed for and applicable to the mounting surface.  Pit Set Mounting: 1.  Use 1/2” EMT. Select a location for the conduit where the MXU’s installed position will not interfere with the meter and allow the MXU to be located as high as possible inside the meter box. The MXU should be kept approximately 1" from the sides of the meter box and positioned so the meter register odometer remains visible for visual confirmation readings. Conduit mounting method calls for driving a length of conduit into the ground at the bottom of the meter box. (If the bottom of the meter box does not  have  an  opening  sufficient  for  driving  the  conduit  vertically  into  the  ground  below,  a  different mounting method may need to be developed.) Place driver on conduit and strike with hammer, driving conduit downward until it is at the desired height. The correct height should be at the point the driver is level with the top of the meter box in most cases. When completely installed, the top of the MXU should be about 1" below the meter box lid. 2.  After installation of conduit, position the opening located in the bottom of MXU over the conduit and press into place. Place meter box cover (lid) into position. Pit set installation is now complete. 3.  TouchRead Sensor Mounting (Optional) – If installing a TouchRead pit-set module, follow the TR/PL mounting instructions on bulletin TR-997 for mounting in the meter box lid. Place meter box cover (lid) into position with the TR/PL sensor in place.   RF Exposure Note  In order to comply with FCC RF Exposure requirements, the Automatic Meter Reading unit must be installed in such a way that there is a 20c”m separation distance between it and all persons during normal operation. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety code 6, obtainable from Health Canada's website www.hc-sc.gc.ca/rpb NOTE:    THE  MANUFACTURER  IS  NOT  RESPONSIBLE  FOR  ANY  RADIO  OR  TV  INTERFERENCE CAUSED  BY  UNAUTHORIZED  MODIFICATIONS  TO  THIS  EQUIPMENT.   SUCH  MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

Navigation menu