Sengled Z02HUB Element hub User Manual Z02 hub

Sengled Co.,Ltd. Element hub Z02 hub

Z02-hub_User Manual

Z01-A19NAE26- Wireless LED BulbZ02-Hub –Sengled HubUser ManualLED + Smart Control
System Features:•••••ENControl Element lighting from anywhere at anytimeSchedule scenes based on timing, brightness and color temperatureView live and historic energy consumption statisticsControl Sengled Element bulbs via local Wi-Fi network or Sengled cloudTrack and report number of power cycles and usage hoursElement Bulb Features•••••••Wireless controlDimmable via Element app, wall switches and most wall dimmersAdjustable color temperature from warm white (2700K) to cool white (6500K)25,000 hour LED lifetimeWide beam angleNo flickering on existing wall dimmers (dimmer compatibility list available on request.)Supports Zigbee HA 1.2.1Element Hub Features:•••Connects up to 50 Element bulbs via the Element mobile appWirelessly control groups and individual Element bulbsSupports Zigbee HA 1.2.1 Element Bulb Specification••••••••••Model: Z01-A19NAE26Power: 9.8WBrightness: 800 lumensBeam Angle: 270°Input: 100-120V AC, 50/60Hz, 88mALight Socket: E26Operating Temperature: -4 °F ~ + 104 °F (-20 °C ~ + 40 °C)Storage Temperature: -40 °F ~ + 158 °F (-40 °C ~ +70 °C)Operating Humidity: 10% ≤ RH ≤ 95%, non-condensingDimensions: Dia: 2.4in (60mm); H: 4.6in (117mm)Element Hub Specification••••Model: Z02-hub Input: 5V DC, 1ADimensions: L: 78mm; W: 78mm; H: 26mmSupport Zigbee HA 1.2.1 and 2.4GHz Wi-FiBox Contents•••••Two Element A19 Bulbs and One HubOne Ethernet CableQuick Start GuideUser ManualLimited Written Express Warranty
ENLocal OperationsReset the hub: The hub has to be reset when changing Wi-Fi networks. Press and hold the white round button on the side of the hub for at minimum eight seconds and then release it, the middle blue signal indicator light on the front of the hub should flash eight times if the reset is successful. Wait for up to 30 seconds for the indicator light to steady.Rejoin wireless network from the bulb: Power cycle the bulb (off then back on) five times quickly. The bulb will blink two times indicating network rejoin.Reset factory default for the bulb: Power cycle the bulb (off then back on) quickly for at minimum ten times. The bulb will blink five times indicating pairing mode.EZ-Mode commissioning from the bulb: Power cycle the bulb (off then back on) seven times quickly to enable EZ-Mode. The bulb will blink to indicate that it is in this mode for three minutes. To exit this mode earlier, power off the bulb via the wall switch, wait for two seconds and then power it back on.Setting the bulb’s dim level via wall switch: Enable dimming by powering the bulb off and then on within one second. The light will gradually change from its current brightness setting to the maximum. Following this, the brightness will change from the maximum to the minimum and finally back to the maximum again. When the brightness is changing, power off the bulb when the bulb reaches the desired dim level. Power the bulb back on and the bulb should now be set to the new dim level. If no power off action is taken, the light will remain at maximum brightness level.*To ensure the following steps work successfully, please power on the bulb first and wait for at least four seconds before taking any of the steps.
System Setup Instructions••ENPlease review the Quick Start guide for instructions on how to set up the Element HubPlease contact customer service via Sengled.com for information on how to purchase additional bulbs. To add additional bulbs, please follow the in-app instructions to scan, power on and add the bulbs to their desired hub as shown below••NOTE: Bulbs associated with another Sengled account must first be deleted and factory reset. Refer to the Local Operations section of the User Manual for instructions on how to factory reset a bulb.NOTE: Bulbs accidentally deleted from a Sengled account must first be factory reset before being re-added.Add a bulbScan QR code for another bulbManual input for another bulbDevicesAdd bulbAdd HubAim the camera at the QR codeAdd a bulbScan QR code for another bulbManual input for another bulbSuccess(1)(4) (5)(3)(2)
Important Safety Instructions•••••••ENThis product is intended for indoor use onlyDo not install the product near any heat sources, such as heaters, radiators, stoves, heat registers or other apparatus that produce heatTo reduce the risk of electric shock, do NOT disassemble. There are no serviceable parts insideDo not clean the device when it is on and connected to the power supplyFor best protection against lightning,unplug or unscrewth-eproducts from its power source duringa stormThe bulb will be hot when in use and should not be touched without taking careDo NOT throw the LED bulb into regular trash at the end of its life. Bring the bulb to a local recycling center for proper disposalZ01-A19FCC ID:2ABX8SH-000000010      IC:12219A-00000000010NOT FOR EMERGENCY LIGHTINGADDED WEIGHT OF THE BULB MAY CAUSE INSTABILITY OF A FREE-STANDING PORTABLE LUMINAIRERISK OF ELECTRIC SHOCK-DO NOT USE WHERE DIRECTLY EXPOSED TO WATERCAUTION:
 FCC STATEMENT FOR USERS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  SECTION 15.21 The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form.  FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT, SECTION 15.105(b) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.  RF RADIATION EXPOSURE WARNING This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance.
 IC Radiation Exposure Statement for Canada    This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.      Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.      Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent is otropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.      Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  User manuals for transmitters equipped with detachable antennas shall also contain the following notice in a conspicuous location:      This radio transmitter (identify the device by certification number, or model number if   Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.      Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s'il fait partie du matériel de catégorie I) a été approuvé par
Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.      IMPORTANT NOTE:   Radiation Exposure Statement:   This equipment complies with “Industry Canada RSS-102 for radiation exposure limits set forth for an uncontrolled environment”.   This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.  L'exposition aux radiations:   Cet équipement est conforme aux «Industrie Canada RSS-102 pour les limites d'exposition aux rayonnements définies pour un environnement non contrôlé".   Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps.