 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 2    July 2010     REVISION TABLE Date Revision  Comment 14/04/2011  4  Environmental condition update 06/04/2011  3  Channel Spacing amendment 31/03/2011 2 Typos amendment 18/03/2011 1 First issue     Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing. SELEX Communications S.p.A. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. SELEX Communications logo is a trademark of SELEX Communications S.p.A. Printed in Italy. © SELEX Communications S.p.A. All Rights reserved.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 3    July 2010    Summary 1. Scope ............................................................................................................................................................... 5 2. First aid for electrical shock and safety rules................................................................................................ 5 2.1 First aid for electrical shock ................................................................................................................. 5 2.1.1 Artificial respiration ........................................................................................................................ 5 2.1.2 Treatment of burns........................................................................................................................... 5 2.2 Product Safety and RF Exposure Compliance.................................................................................... 7 2.2.1 RF Exposure Compliance................................................................................................................ 7 2.2.2 Electrostatic protection .................................................................................................................... 7 3. Technical/Environmental Specification ........................................................................................................ 8 4. ECOS-D DMR4000 – encoding criteria ...................................................................................................... 10 4.1 RGW4000/RBS4000 ............................................................................................................................ 10 5. Device Assembly and composition ............................................................................................................... 12 5.1 Connector positions ............................................................................................................................. 14 6. Installation.................................................................................................................................................... 15 6.1 Overview............................................................................................................................................... 15 6.1.1 Installation Pre-requisites .............................................................................................................. 15 6.1.2 Unpack........................................................................................................................................... 16 6.1.3 Mechanical installation.................................................................................................................. 16 6.1.4 Electrical wiring ............................................................................................................................ 17 6.1.5 Unit grounding............................................................................................................................... 17 6.2 Power Supplies interfaces ................................................................................................................... 19 6.2.1 48 Vdc input .................................................................................................................................. 19 6.3 Radio Interfaces................................................................................................................................... 21 6.3.1 TX N type connector ..................................................................................................................... 21 6.3.2 RX N type connector ..................................................................................................................... 22 6.4 Line interfaces...................................................................................................................................... 23 6.4.1 4W and 4W+E/M Link.................................................................................................................. 23 6.4.2 AF in/out........................................................................................................................................ 30
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 4    July 2010    6.5 Syncronization Interfaces ................................................................................................................... 34 6.5.1 Main GPS Interface ....................................................................................................................... 34 6.6 Other Interfaces................................................................................................................................... 35 6.6.1 Door break-in................................................................................................................................. 35 6.6.2 LAN Interface................................................................................................................................ 36 6.6.3 Serial Interface............................................................................................................................... 38 6.6.4 Auxiliary Serial Interface .............................................................................................................. 40 6.6.5 Digital Input/Output Interface ....................................................................................................... 43 6.6.6 Local Microphone Interface .......................................................................................................... 45 7. Configuration ............................................................................................................................................... 47 8. Maintenance ................................................................................................................................................. 47 8.1 Module features, alarms and troubleshooting .................................................................................. 47 8.1.1 CORE module ............................................................................................................................... 47 8.1.2 4 Lines Interface module – LIF ..................................................................................................... 51 8.1.3 SWITCH module........................................................................................................................... 52 8.1.4 DC/DC module.............................................................................................................................. 53 8.1.5 Radio Receiver and Transmitter module - RTX ............................................................................ 53 8.1.6 Power Amplifier module - PA....................................................................................................... 55 8.2 Power modules maintenance precaution ........................................................................................... 57 8.3 Module removal................................................................................................................................... 58 8.4 Back card removal............................................................................................................................... 59 8.5 Local Maintenance Interface.............................................................................................................. 60 8.6 Local Test AF Interface ...................................................................................................................... 62 8.7 Remote Maintenance Interface .......................................................................................................... 63
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 5    July 2010    1. Scope  This manual provides experienced technicians familiar with similar types of equipment with information which permit the installation and maintenance of the described product, whose characteristics are described in the Technical specification Section. This document does not contain information of the maintenance and configuration software that are provided with the software itself. Information contained in this document are valid only for the described ECOSD RBS4000I U2110WA0C14W6E100S1V1G2 (FCCID: X5YF967DHDE-IP) of the ECOS-D DMR4000 Family of products, optional cards and ancillaries included. The technicians must use only the part of information related to the RBS really shipped. 2.  First aid for electrical shock and safety rules 2.1 First aid for electrical shock Do not touch the patient with bare hands until the circuit has been opened. pen the circuit by switching off the line switches. If that is not possible protect yourself with dry material and free the patient from the conductor. 2.1.1 Artificial respiration It is important to start mouth resuscitation at once and to call a doctor immediately. Suggested procedure for mouth to mouth resuscitation method is described in Table 1. 2.1.2  Treatment of burns This treatment should be used after the patient has regained consciousness. It can also be employed while artificial respiration is being applied (in this case there should be at least two persons present). Warning • Do not attempt to remove clothing from burnt sections • Apply dry gauze on the burns • Do not apply ointments or other oily substances.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 6    July 2010     Table 1 First aid
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 7    July 2010    2.2 Product Safety and RF Exposure Compliance 2.2.1  RF Exposure Compliance The described product is intended for use in occupational/controlled conditions, where users have full knowledge of their exposure and can exercise control over their exposure to meet FCC limits. This RBS is NOT authorized for any other use. 2.2.2 Electrostatic protection When the equipment units are provided with the plate, shown in Figure 1 it means that they contain components electrostatic charge sensitive.  Figure 1 Electrostatic sensitive equipment In order to prevent the units from being damaged while handling, it is advisable to wear an elasticised band (Figure 2) around the wrist ground connected through coiled cord (Figure 3) to the appropriate point on the RBS (Figure 4)  Figure 2 Antistatic band  Figure 3 Coiled Cord  Figure 4 Antistatic contact point Antistatic contact point
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 8    July 2010    3. Technical/Environmental Specification The main characteristic of the device are: Radio Frequency:  Frequency range    450 – 526 MHz  Channel Spacing    12,5 kHz  Channel step      5 kHz – 6,25 kHz RF Power      10 – 110 Watt (step 0,1 dB) Modulation type     Dual mode  Analog  FM/PM (EN 300 086 – EN 300 113)    11K0F3E/11K0G3E Digital  4FSK (TS 102 361-1,2,3)  7K60FXD/7K60FXE  C4FM 8K10F1D/8K10F1E CTCSS       67 – 254.1 Hz (step 0,1 Hz) DCS    yes Antenna connector    50 Ohm Emission mode   Duplex/Simplex  Receiver sensitivity    Analog FM (12,5 kHz): ≤ -112 dBm @ 20 dB SINAD psofo     Digital 4FSK: ≤  -118 dBm @ BER = 5x10-2     Digital C4FM: ≤  -118 dBm @ BER = 5x10-2 Power supply:  Input voltage     48 Vdc (35 ÷ 75 Vdc - galvanically insulated) Current drain         Stand-by    0,9 A max @ 48 Vdc     Transmit    7 A max @ 48 Vdc           NOTE: current drain values are for fully equipped devices.  Environmental condition: Operating temperature    -30 - +60 °C (-22 - +140 °F)
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 9    July 2010    This is the temperature measured in close proximity to the device. If the device is mounted in a cabinet, the temperature within the cabinet is measured. Humidity    should not exceed 90% relative humidity @ 50°C (122°F) non condensating Air Quality   For equipment operating in an environmentally controlled environment with repeater(s) rack mounted, the airborne particle level must not exceed 25 µg/m³. For equipment operating in an area which is not environmentally controlled (repeater(s) cabinet mounted), air borne particle level must not exceed 90 µg/m³. Equipment Ventilation  the repeater is equipped with two cooling fans that are used to provide forced convection cooling. Customer-supplied cabinets must be equipped with ventilation slots or openings in the front (for air entry) and back or side panels (for air to exit). If several repeaters are installed in a single cabinet, be sure ventilation openings surround each repeater to allow for adequate cooling. A minimum of ½ RU (4,4 cm – 0,8 inches) must be left among devices installed in the same cabinet.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 10    July 2010    4. ECOS-D DMR4000 – encoding criteria The ECOS-D DMR4000 family includes several products. This section describes the encoding criteria for models of the families   - RGW4000  - RBS4000  4.1 RGW4000/RBS4000 Tab. 4.1:  Product Options for the family Rxx4000 General Code: ECOSD Rxx4000y aabbbWAcde4WgE1hmSnVpGr Type of equipment  Rxx xx = GW  - equipment Dual CORE xx = BS  - equipment Single CORE Type of backplane  4000y y = A  - backplane Type A y = B  - backplane Type B y = C  - backplane Type C y = G  - backplane Type G (dual-core)   y = H  - backplane Type H for 25W VHF/UHF and 110W VHF  y = I  - backplane Type I for 110W UHF (also valid for 110W VHF) Frequency Band  aa aa = V1 (66 - 88 MHz)  aa = V2 (145 - 174 MHz)  aa = V3 (136 - 174 MHz)  aa = U1 (400 - 470 MHz)   aa = U2 (450 - 526 MHz)   aa = U3 (854 - 921 MHz)   aa = 00 - indicates no part radio RF Power  bbbW bbb = 025 - Pout 25W bbb = 110 - Pout 110W bbb = 000 - indicates no Power Amplifier module Power Supply  Acde A - indicates 12Vdc power supply c = 0 - does not provide 12Vdc power supply c = 1 - provides 12Vdc power supply d = 0 - indicates the absence of alternatives at 12Vdc powr supply  d = B - indicates 24Vdc power supply
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 11    July 2010    d = C - indicates 48Vdc power supply d = D - indicates 72Vdc power supply d = E - indicates 230Vac power supply e = 1 - indicates one power supply module e = 2 - indicates two power supply modules e = 3 - indicates three power supply modules … e = 0 - indicates no power supply modules 4 Wires interfaces  4Wg  g = 1 - indicates one LIF (Line Interface module) with back-card g = 2 - indicates two LIF (Line Interface modules) with back-card  … g = 0 indicates no Line Interface modules and no back-card E1 Interfaces  E1hm   h = C - indicates back-DIF (Digital Interface back-card) with   coax connectors @75 Ohm unbalanced  h = R - indicates back-DIF (Digital Interface back-card) with RJ45 connectors @120 Ohm balanced  h = 0 - indicates no back-DIF m = 1 - indicates one Digital Interface module m = 2 - indicates two Digital Interface modules … m = 0 - indicates no Digital Interface modules Option Board - SOIP  Sn n = 1 - indicates one SOIP piggy-back on one CORE module  n = 2 - indicates two SOIP piggy-back on two CORE modules n = 0 - indicates no SOIP piggy-back Option Board  -VOCODER Vp p = 1 - indicates one VOCODER piggy-back on one CORE module p = 2 - indicates two VOCODER piggy-back on two CORE modules  p = 0 - indicates no VOCODER piggy-back Synchronization -GPS receiver Gr  r = 1 - indicates one GPS receiver piggy-back on one CORE module (Master) r = 2 - indicates two GPS receiver piggy-back on one CORE module (Master) r = 0 - indicates no GPS receivers piggy-back
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 12    July 2010    5.  Device Assembly and composition
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 13    July 2010
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 14    July 2010     5.1 Connector positions                 Microphone/AF test Power on/off switch Antistatic contact GPS antennaDoor AlarmAUX Serial portRF RX antenna  I/O portRF TX antenna 48 VDC inputLAN port4W(+E/M) local port Main Serial port 4x4W(+E/M) link ports Loudspeaker  Main Power on/off switch
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 15    July 2010    6. Installation 6.1 Overview The device can be shipped preinstalled in a cabinet or not. If it is not shipped preinstalled in a cabinet, after unpacking, mechanical installation takes place, followed by electrical connections as described in this document. The device may be installed in any location suitable for electronic communications equipment, provided that the environmental conditions do not exceed the equipment specifications for temperature, humidity, and air quality and that the access to that location is restricted as described below: •  access can only be gained by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that be taken; and •  access is through the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location 6.1.1 Installation Pre-requisites To ensures the best possible performance and reliability of the described equipment pre-installation planning is required. This includes considering the mounting location of the repeater in relation to input power and antennas. Also to be considered are site environment conditions, the particular mounting method and required tools and equipment. To plan the installation, please pay particular attention to environmental condition at the site, ventilation requirements, and grounding and lightning protection as described in this manual. After that, following the instruction given in this manual: •  Unpack and inspect the equipment. •  Mechanical install the equipment at the site. •  Make necessary electrical wiring: - Unit Grounding -  DC input cabling -  Coaxial cables to transmit and receive antennas •  Perform a post-installation function checkout test of the equipment to verify proper installation. •  Proceed to customize the repeater parameters per customer specifications (e.g. operating frequency, PL, codes, color code, etc.)
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 16    July 2010    6.1.2 Unpack  Inspect the equipment for damage immediately after unpacking and make a report of the extent of any damage to the transportation company and to SELEX Communications S.p.A. The following items are packed together: •  ECOS-D A2T Radio Base Station •  DC power cable •  This manual 6.1.3 Mechanical installation The device is shipped in a box. Upon delivery, the equipment must be removed from the container (see Unpack section) and transferred to a rack or cabinet. Refer to this manual for all the installation requirements. The device is designed to be fitted in a 19” cabinet using 3 RU of space.  Customer-supplied cabinets and racks must have mounting rail and hole spacing compatible with EIA Universal 48.3 cm (19 inches) specifications. Cabinets must provide adequate ventilation and must meet the following criteria: •  45.0 cm (17.71 inches) deep •  48.3 cm (19 inches) wide •  13.4 cm (5.25 inches) high M6 screws
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 17    July 2010    •  Two mounting rails 5 cm (2 inches) from front cabinet with front mounting holes 5.7 cm (2.25 inches) apart (center to center). The front of the device is provided with four holes for M6 screws. This permits to fasten the device to a 19” rack by means of 4 M6 screws. If several devices are installed in a single cabinet, be sure equipment have to be spaced at least by 1/2 RU (2,2 cm, 0,8 inches).to allow for adequate cooling. Cabinets must have a least 15 cm (6 inches) of open space between the air vents and any wall or other cabinets. This allows adequate air flow. When multiple cabinets (each equipped with several repeaters) are installed in an enclosed area, ensure appropriate ventilation and consider air conditioning or other climate control equipment to satisfy the temperature requirements.  6.1.4 Electrical wiring The electrical wiring must be done using appropriate cables thus assuring the equipment responds to the electromagnetic compatibility standards. The cable terminates to flying connectors which have to be connected to the corresponding connectors on the equipment rear panel. The connector of the power cable supplied with the product is the means to disconnect the device from the power source. Position and pin–out of the equipment connectors are available in the appropriate section in the following of this document.  6.1.5 Unit grounding The device is equipped with a ground nut located on the rear panel of the device and identified by a  label. This nut must be used for a direct connection of the device to the site grounding, even if the device is included in a cabinet. All antenna cables and DC power cabling should be properly grounded and lightning protected. Failure to provide proper lightning protection may result in permanent damage to the radio equipment.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 18    July 2010     Figure 5 Ground connector Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor Ground  M6 nut  Section area ≥ 6 sq. mm Note. Resistance between ground terminal and other metallic parts of the device verified applying between the two sides a current of 32 A for 4 minutes. Ground connector
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 19    July 2010    6.2 Power Supplies interfaces 6.2.1  48 Vdc input Use the connector marked in red to connect RBS to the output of the 48 VDC power supply.  Each level must be connected separately the 48 VDC power supply. The RBS is galvanically insulated..  Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor Power supply 35 – 75 Vdc  Polarised  SUB–D  3W3  female connector Section of each wire ≥ 4 sq.mm. (for length < 6 m)  D-SUB 3W3 female pinout  PIN  A1 Negative voltage A2 Not used A3 Positive voltage    (soldering side view) Hereafter the power cable supplied with the 48 Vdc powered device is shown. The cable is provided with D-SUB 3W3 female connector and a 30A fuse.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 20    July 2010     The 48 Vdc Back Card hosts three 10A fuses. Position of FU1, FU2 and FU3 is indicated in the figure below.   Electrical characteristics of the fuses are described in the table below. Ampere rating (A)  Voltage rating (V)  Nominal Melting (I2 A2 Sec.) 10 125 26.46
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 21    July 2010    6.3 Radio Interfaces 6.3.1  TX N type connector In RBS without branching and using duplex mode of operation connect the transmitter cable to the “TX OUT” connector as shown in the following figure.   Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor TX Antenna  N male connector  50 ohm coaxial cable with double shield
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 22    July 2010    6.3.2  RX N type connector In RBS without branching and using duplex mode of operation connect the transmitter cable to the “RX IN” connector as shown in the following figure.   Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor Antenna  N male connector  50 ohm coaxial cable with double shield
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 23    July 2010    6.4 Line interfaces 6.4.1  4W and 4W+E/M Link If the RBS is equipped with a LIF module on the rear panel 4 4W+E/M connectors are present. The following figure shows the rear panel of the LIF module. Configuration of the feature of this four links is out of the scope of this manual. The electrical interface is described in this section. Usually these AF links are used to establish RBS to RBS links or RBS to RNFE links.    Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor 4W or 4W+E/M Link port  RJ45 male connector  AWG 24 Category 5   4x 4W or 4W(+E/M)
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 24    July 2010    4W+E/M line RJ45 female pinout PIN  1 Mouth (M+) 2 Mouth (M-) 3 Ear (E+) 4 AF_OUT (-) 5 AF_OUT (+) 6 Ear (E-) 7 AF_IN (-) 8 AF_IN (+)    4W+E/M and 4W line usage PIN   4W+E/M  4W 1  M (+)  Mouth signal +  not connected 2  M (-)  Mouth signal -  not connected 3  E (+)  Ear Signal +  not connected 4  AF_OUT (-)  600 Ohm Balanced OUT AF  600 Ohm Balanced OUT AF 5  AF_OUT (+)  600 Ohm Balanced OUT AF  600 Ohm Balanced OUT AF 6  E (-)  Ear Signal -  not connected 7  AF_IN (-)  600 Ohm Balanced IN AF  600 Ohm Balanced IN AF 8  AF_IN (+)  600 Ohm Balanced IN AF  600 Ohm Balanced IN AF  E/M pin usage PIN   Balanced Unbalanced 1  M (+)  Mouth signal +  Mouth signal 2  M (-)  Mouth signal -  not connected 3  E (+)  Ear Signal +  Ear Signal 6  E (-)  Ear Signal -  not connected
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 25    July 2010    4W cabling example: link between RBS A and RBS B RJ-45, RBS A side  RJ-45, RBS B side M (+)  1  Not connected  Not connected  1  M (+) M (-)  2  Not connected  Not connected  2  M (-) E (+)  3  Not connected  Not connected  3  E (+) AF_OUT (-)  4  White-blue  White-orange 4 AF_OUT (-) AF_OUT (+)  5  Blue  Orange  5  AF_OUT (+) E (-)  6  Not connected  Not connected  6  E (-) AF_IN (-)  7  White-orange  White-blue 7 AF_IN (-) AF_IN (+)  8  Orange  Blue 8 AF_IN (+)  E/M Hardware Line settings All the E/M signals share a common voltage reference. The four Mouth signals may be hardware configured independently. The four Ear signals share the same hardware configuration in couple of lines. For unbalanced settings connect the two communicating entities to the same ground. E/M Type I Interface Model E/M Type I is the original E/M lead signaling arrangement and it is the most common interface type in North America. The following diagram displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expects to see active conditions on the E−lead and signal active to the remote device on M−lead.  E/M Type II Interface Model E/M Type II provides a four−wire fully−looped arrangement that provides full isolation between the trunks and signaling units. The following table displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expects to see active conditions on the E−lead and signal active to the remote device on M−lead. RBS side
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 26    July 2010      E/M Type V Interface Model E/M Type V interface is a symmetrical two−wire lead arrangement that signals in both directions by means of open for not active and ground for active signalling. The following table displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expects to see active conditions on the E−lead and signal active to the remote device on M−lead.  E/M Proprietary Type Interface Model E/M Proprietary Type provides a four−wire fully−looped arrangement that provides full isolation between the trunks and signaling units. The following table displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expects to see active conditions on the E−lead and signal active to the remote device on M−lead.  M+M-E+E-M+M-E+E- +48v RBS side RBS side RBS side
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 27    July 2010    E/M Hardware settings      Type I (Unbalanced)Type II (Balanced) Type V (Unbalanced) proprietary  (Balanced) IP3 1  ON  OFF  OFF  ON  2  ON  OFF  OFF  ON IP5 1  OFF  ON  ON  OFF  2 voltage reference OFF ON ON OFF IP6  1  E line 3&4  ON  OFF  ON  OFF   2  E line 1&2  ON  OFF  ON  OFF IP7  1  M line 2  ON  OFF  ON  OFF   2  M line 1  ON  OFF  ON  OFF IP8  1  M line 4  ON  OFF  ON  OFF   2  M line 3  ON  OFF  ON  OFF    Back card deep switch positioning  Where, in the equipment described in this document, a 4 wires interface towards a common communication network is used, it is mandatory to use 4 (four) different copper pairs: two of them are IP3 IP5 IP7 IP8 IP6
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 28    July 2010    used to transfer from one to the other RBS the user payload and two of them are optionally used to transfer E and M criteria. All the signals are exchanged using a balanced type of connection, avoiding any ground reference. For the two copper pairs used for exchanging the user payload, the impedance of the interface is 600 Ohm. The characteristics of the pairs must be as follows: Amplitude: Amplitude characteristic of the media must comply with FIGURE 2/G.712 (ITU-T Rec.G.712 page 8). The mask is shown below. Anyway in the audio band from 300 Hz to 3400 Hz the response must be +/- 1,5 dB with respect to the nominal level of –10 dBm. 0 200 300 1020 2400 3000 3400 3600 HzdBT1511850-020–0.50.50.91.8Loss(see Note)Frequency (f )NOTE  –  In some applications in which several PCM channels may be connected in tandem, it may benecessary to extend the +0.5 dB limit from 2400 Hz to 3000 Hz.  Group delay: Group delay characteristic of the media must comply with FIGURE 6/G.712 (ITU-T Rec.G.712 page 10). The mask is shown below. 1000 2600 Hzms0T1511890-02500 600 28000.250.751.50Group delay distortionFrequency (f) Insertion loss:
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 29    July 2010    The insertion loss must be 0dB +/- 3 dB. This must be true also with regard to the aging of the media physically used. Noise: The characteristic of the media must comply with prescriptions contained in chapter 9 (noise) of book III.4-Rec.G.792 page 4 and following. Diaphony: The pairs of the media used to transport the user payload must have a diaphony attenuation greater than 40 dB. E/M time response: The response time of E/M criteria must be less than 100 msec.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 30    July 2010    6.4.2 AF in/out If the RBS is equipped with a CORE back card module a 4W+E/M link is available. The following figure shows the rear panel of the CORE module. Configuration of this AF link is out of the scope of this manual. Usually it is used to provide an AF signal to a third party audio device.  Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor 4W or 4W+E/M Link  RJ45 male connector  AWG 24 Category 5   AF 4W+E/M line RJ45 female pinout PIN  1 Mouth (M+) 2 Mouth (M-) 3 Ear (E+) 4 AF_OUT (-) 5 AF_OUT (+) 6 Ear (E-) 7 AF_IN (-) 8 AF_IN (+)    Link to external AF
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 31    July 2010    4W+E/M line usage PIN   4W+E/M 1  M (+)  Mouth signal + 2  M (-)  Mouth signal - 3  E (+)  Ear Signal + 4  AF_OUT (-)  600 Ohm Balanced OUT AF 5  AF_OUT (+)  600 Ohm Balanced OUT AF 6  E (-)  Ear Signal - 7  AF_IN (-)  600 Ohm Balanced IN AF 8  AF_IN (+)  600 Ohm Balanced IN AF  E/M pin usage PIN   Balanced Unbalanced 1  M (+)  Mouth signal +  Mouth signal 2  M (-)  Mouth signal -  not connected 3  E (+)  Ear Signal +  Ear Signal 6  E (-)  Ear Signal -  not connected  E/M Hardware Line settings For unbalanced settings connect the two communicating entities to the same ground. E/M Type I Interface Model E/M Type I is the original E/M lead signaling arrangement and it is the most common interface type in North America. The following diagram displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expect to see active conditions on the E−lead and signal active to the remote device on M−lead.  E/M Type II Interface Model E/M Type II provides a four−wire fully−looped arrangement that provides full isolation between the trunks and signaling units. The following table displays the sent signal states for active/not active RBS side
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 32    July 2010    signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expect to see active conditions on the E−lead and signal active to the remote device on M−lead.   E/M Type V Interface Model E/M Type V interface is a symmetrical two−wire lead arrangement that signals in both directions by means of open for not active and ground for active signalling. The following table displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expect to see active conditions on the E−lead and signal active to the remote device on M−lead.  E/M Proprietary Type Interface Model E/M Proprietary Type provides a four−wire fully−looped arrangement that provides full isolation between the trunks and signaling units. The following table displays the sent signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to signal a seizure. The RBS expect to see active conditions on the E−lead and signal active to the remote device on M−lead. M+M-E+E-RBS side RBS side
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 33    July 2010      E/M Hardware settings  Type I (Unbalanced) Type II (Balanced) Type V (Unbalanced) proprietary  (Balanced) IP1 1  ON  OFF  OFF  ON  2  ON  OFF  OFF  ON IP2 1  OFF  ON  ON  OFF  2  OFF  ON  ON  OFF IP3 1 OFF OFF OFF OFF  2 ON OFF ON OFF   Back card deep switch positioning  M+M-E+E- +48v IP1 IP2 IP3 RBS side
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 34    July 2010    6.5 Syncronization Interfaces 6.5.1  Main GPS Interface In order to connect the Main GPS antenna to the RBS, connect the GPS antenna to the  SMA-BNC “Main GPS” connector shown in the following figure.       Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor GPS  SMA male connector  50 ohm coaxial cable with double shield  Main GPS Antenna Spare GPS Antenna
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 35    July 2010    6.6 Other Interfaces 6.6.1 Door break-in Insert the connector in the front or rear door break-in connector shown in the following figure.  Connect the three devices to the cable coming from the door as shown in the following figure.    Front Door Break-in Rear Door Break-in
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 36    July 2010    6.6.2 LAN Interface The LAN Interface is a 10BASE-T 100BASE-TX autosensing Ethernet interface with a standard RJ45 connector. Connect it to a hub/switch to provide LAN access to the feature of the RBS. Available features depend on the settings of the RBS.     Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor LAN  RJ45 male connector  AWG 24 Category 5   LAN port
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 37    July 2010    LAN RJ45 female pinout PIN    1  RX+ Receive Data + 2  RX-  Receive Data - 3  TX+ Transmit Data + 4   not used 5   not used 6  TX-  Transmit Data - 7   not used 8   not used  LAN RJ45 male cabling PIN   EIA/TIA 568A EIA/TIA 568B 1 TX+ White/Green  White/Orange 2 TX- Green  Orange 3 RX+ White/Orange White/Green 4   Blue  Blue 5   White/Blue  White/Blue 6 RX- Orange  Green 7   White/Brown  White/Brown 8   Brown  Brown    To connect the RBS to an Ethernet hub/switch use a straight cable (EIA/TIA 568A or EIA/TIA 568B on both ends). To connect the RBS directly to an Ethernet host use a cross cable (EIA/TIA 568A on one end and EIA/TIA 568B on the other end).
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 38    July 2010    6.6.3 Serial Interface The Serial Interface is an RS232 interface with a standard female type D DCE connector. Connect it to a DTE to provide serial access to the RBS. Available features depend on the settings of the RBS.     Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor RS232  Male type D connector with 9 pins and shielded holder 9 conductor cable with double brass sheath type interconductor  Serial Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 39    July 2010    RS232 RS232 standards are defined by EIA/TIA (Electronic Industries Alliance /Telecommunications Industry Association). RS232 defines both the physical and electrical characteristics of the interface. RS232 is an Active LOW voltage driven interface and operates at +12V to -12V. RS232 is a serial interface for the transmission of point to point digital data. Description of the connector’s pins is from DTE to DCE. The RBS acts as a DCE. RS232 female pinout PIN   Mean 1   not used 2  RX  Data from DCE to DTE 3  TX  Data from DTE to DCE 4   not used 5 GND Ground 6   not used 7  RTS  Ready To Send (from DTE) 8  CTS  Clear To Send (to DTE) 9   not used   Complete RS232 female pinout (only on request) PIN   Mean 1   not used 2  RX  Data from DCE to DTE 3  TX  Data from DTE to DCE 4  DTR  Data Terminal Ready (from DTE) 5 GND Ground 6  DSR  Data Set Ready (to DTE) 7  RTS  Ready To Send (from DTE) 8  CTS  Clear To Send (to DTE) 9   not used
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 40    July 2010    6.6.4  Auxiliary Serial Interface The Auxiliary Serial Interface is an optional RS232, RS422 or RS485 interface with a standard female type D DCE connector. Connect it to a DTE to provide serial access to the RBS. Available features depend on the settings of the RBS.    Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor RS232 RS422 RS485  Male type D connector with 9 pins and shielded holder 9 conductor cable with double brass sheath type interconductor  Pinout of the three tipes of serial interface are described below. AUX Serial Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 41    July 2010    RS232 RS232 standards are defined by EIA/TIA (Electronic Industries Alliance /Telecommunications Industry Association). RS232 defines both the physical and electrical characteristics of the interface. RS232 is an Active LOW voltage driven interface and operates at +12V to -12V. RS232 is a serial interface for the transmission of point to point digital data. Description of the connector’s pins is from DTE to DCE. The RBS acts as a DCE. RS232 female pinout PIN   Mean 1   not used 2  RX  Data from DCE to DTE 3  TX  Data from DTE to DCE 4   not used 5 GND Ground 6   not used 7  RTS  Ready To Send (from DTE) 8  CTS  Clear To Send (to DTE) 9   not used   RS422 RS422 is a balanced serial interface for the transmission of point to point digital data. The advantage of a balanced signal is the greater immunity to noise. The EIA describes RS422 as a DTE to DCE interface for point-to-point connections. Description of the connector’s pins is from DTE to DCE. The RBS acts as a DCE. RS422 female pinout (only on request) PIN   Mean 1 GND Ground 2  TX +  Data from DTE to DCE 3   not used 4  RX +  Data from DCE to DTE 5 GND Ground 6   not used 7  TX -  Data from DTE to DCE 8   not used 9  RX -  Data from DCE to DTE
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 42    July 2010    RS485 RS485 is a balanced serial interface for the transmission of digital data. The advantage of a balanced signal is the greater immunity to noise. Point to point or multi-point behaviour of this serial interface is software dependent and is out of the scope of this manual. Description of the connector’s pins is from DTE to DCE. The RBS acts as a DCE. RS485 female pinout (only on request) PIN   Mean 1   not used 2 RTX + Data 3   not used 4   not used 5 GND  Ground 6   not used 7 RTX - Data 8   not used 9   not used
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 43    July 2010    6.6.5  Digital Input/Output Interface The RBS manages 4 digital outputs. The connector is located on the rear of the RBS and is shown in red in the following figure.    Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor User I/O  Socket block B2L 3.5/20LH  Section of each wire ≤ 1 sq.mm. (AWG 18)  I/O Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 44    July 2010    I/O Socket block B2L male pinout type contact   out  1  power supply alarm (*) out 2 temperature alarm (*) out  3  synchronization alarm (*) out  4  RF power alarm (*) in 1 not used in 2 not used in 3 not used in 4 not used in A1 not used in A2 not used    (*) The meaning of the digital outputs depends on the firmware release of the RBS. In the shown example the meaning is as follows:  Output 1: power supply alarm. When the RBS is supplied from battery the output is closed.  Output 2: RBS temperature alarm. When the temperature is over a defined maximum value the output is closed.  Output 3: RBS synchronization alarm. When the RBS loses synchronisation the output is closed.  Output 4: RF power alarm. When the PA transmitting power is 3 dB below the right power level the output is closed.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 45    July 2010    6.6.6  Local Microphone Interface The local microphone interface permits to connect a microphone to the RBS. Features related with PTT press and the AF of the microphone are out of the scope of this manual.  Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor Microphone  Male type D high density connector with 15 pins  Section of each wire ≤ 1 sq.mm. (AWG 18)   Microphone Local Microphone Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 46    July 2010    D-SUB HD 15 female pinout PIN   Mean 1 GND  Ground 2   not used 3   not used 4   not used 5   not used 6  AF in  Audio Frequency input to RBS 7   not used 8   not used 9   not used 10   not used 11  PTT  Push To Talk input to RBS 12   not used 13 DGND  Digital Ground 14   not used 15 VDD    (soldering side view)
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 47    July 2010    7. Configuration The hardware configuration, where applicable, is described in the installation section of this manual. Hardware configuration is limited only to hardware related characteristics such as electrical interfaces. A parameter configuration must be done to adjust each device to the user need. This procedure is described in the manual of the configuration software. Please refers to it for more information.  A list of values for each parameter for each device is provided in a separate document on demand. Please refer to it to set the proper value for each parameter. To connect the PC with the configuration software to the RBS follow the procedure described in the Local Maintenance Interface section. 8. Maintenance 8.1 Module features, alarms and troubleshooting 8.1.1 CORE module  The CORE module, for its versatility and potentiality, is the core of ECOS-D RBS. This module is equipped with devices for numerical computation (DSP, FPGA) and control (microprocessor). The primary functionalities of the Core Module are: •  MMI (Man Machine Interface) to allow an operator to interact with the device  •  Main Simulcast Management, implementing the voting algorithm, equalization and a matrix of AF signals. •  local and remote management of the device. The module is able to receive the input reference source from multiple clock signals: •  Internal GPS receiver (up to 2) •  AF tone (eg, tone at 3400 Hz via from an external source through LIF or DIF module) •  2,048 MHz (G.703) The choice of input clock signal is performed according to a configurable logic that normally assigns higher priority to the GPS signal. The module provides as its output the following clock signals to all the other modules of the RBS: •  RBS main reference clock (26 MHz)
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 48    July 2010    •  PPS main and / or spare The CORE module can accommodate also two option boards: •  The SoIP piggy back (Simulcast over IP) that allows the CORE module to manage IP link towards other RBS •  The Vocoder piggy back, that allows the CORE module to manage the digital voice The CORE MMI makes available to a technical operator the following functionalities. •  Radio frequencies settings (RX e TX); •  RF transmission power settings (Hi / Low); •  Enable / disable of input/output lines (radio and wired); •  Speak and listen on selectable interfaces; •  Measures: o  power  supply (V); o  RSSI (dBm); o  RF transmit power (dBm); •  voted signal; •  Selection and management of Audio Frequency (AF) signals for test purposes; •  Lock / unlock of voice in local speaker (radio squelch or criterions); •  Speaker volume setting;  •  Display brightness setting; •  Menu language setting; The MMI is composed by a 8 characters display (each character is 5 x 7 pixels) and a Keypad The keypad is composed by 16 buttons: SQ (Squelch), Fn (Function), +, -, ↵, C (cancel) and 0 ÷ 9. In the following a brief summary of their use is given. SQ   Use it to open/close the analog squelch of the device Fn  Use it to switch between stand-by mode and menu mode. + / -   These are multi-function buttons: they are used for navigation in menu, to up and down speaker volume and display brightness. ↵   in menu mode use it to confirm the choice. C   In menu mode use it to go back to previous menu.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 49    July 2010    0 ÷ 9   In menu mode use them to insert the value of parameters where required The menu tree is described in the following table. Menu level 1 2 3 4 5 1. Freq.RX 1. View Freq.  RTX 2. Freq.TX 1. Low 1. Radio 2. RF Power  PA 2. Hi 1. Brightn.     Italiano   2. Display 2. Language English   1. IP Address     1. Settings 3. Network 2. Net mask     RTX       1. L1     2. L2     3. L3     LIF 4. L4     1. L1     2. L2     3. L3     DIF 4. L4     1. RRXa     RRX 2. RRXb     2. Spk/Lstn CORE       ON 1. RX OFF ON RTX 2. TX OFF ON 1. RXa OFF ON RRX 2. RXb OFF ON L1 OFF ON L2 OFF ON L3 OFF ON 1. Inhibit LIF L4 OFF 1. TS 1   1. Digital 2. TS 2   3. Commands 2. Voice 2. Analog     RTX    RRXa  1. RSSI RRX RRXb  2. DC       3. Voter       4. Measure 4. RF Power  PA     RTX      5. AF Test LIF 1. L1
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 50    July 2010    Menu level 1 2 3 4 5 2. L2     3. L3       4. L4     ON     1. Monitor OFF     M GPS     2. GPS FIX S GPS     List     6. Status 3. Sync. Log Cancel     ON     1. Monitor OFF     List     7. Diagnostic 2. Err Log Cancel
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 51    July 2010    8.1.2  4 Lines Interface module – LIF   The "4 Lines Interface” (LIF) module is the module that is able to manage up to 4 lines with 4W interface + (E&M). This module is equipped with devices for numerical computation (DSP, FPGA) and control (microprocessor) combined with the electrical interfaces for the 4 wires lines. The “Line Interface” (LIF) module is also able to manage redounded links over the 4 wires interfaces.  4 wires interfaces are used by the device to connect this Radio Base Station to up to other 4 Radio Base Stations to build a Simulcast network. The front panel is provided with bi-color leds to help in troubleshooting the system. The table below describes the meaning of the leds: LED  Color  Label  Description 1  Green  Line 1 RX   Line 1 on RX  Red  Line 1 TX  Line 1 on TX 2  Green  Line 2 RX   Line 2 on RX  Red  Line 2 TX  Line 2 on TX 3  Green  Line 3 RX   Line 3 on RX  Red  Line 3 TX  Line 3 on TX 4  Green  Line 4 RX   Line 4 on RX  Red  Line 4 TX  Line 4 on TX 5  Green  Status1   Red  DATA bus fail  failure MTCH of DSP 6  Green  Status2   Red  Logic fail  µP and DSP not communicate 7  Green  CTRL bus busy  Activity on Control Bus  Red  CTRL bus fail  failure of BUS µP 8  Green  Upload   Ongoing download code   Red  Upload Fail  Download code KO
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 52    July 2010    8.1.3 SWITCH module The Switch module realizes a "solid state" switch (MOSFET) device for the distribution of the power necessary for the proper working of all the modules of the ECOS-D RBS. In particular its primary task is to distribute the 13,2 Vdc nominal voltage (Master voltage) and 7 Vdc nominal voltage (Slave voltage). The 7 Vdc Slave voltage is used by all the other modules to power their logic. It is generated by the switch module for direct conversion from the 13,2 Vdc Master voltage. The switch module provides: •  ON / OFF of all the modules on the same RBS •  Protection against Extra Current (short circuit or overload > 22 A ± 5%) •  Protection against Extra voltage (maximum input voltage equal to 30 Vdc ± 5%) •  Protection against voltages outside the guaranteed operating range [10.8 ÷ 15.6 Vdc]. •  Protection against reverse polarity input voltage. •  Protection against over temperature inside the module itself (≥ 100 ° C ± 1%). The front panel is provided with bi-color leds to help in troubleshooting the system. The table below describes the meaning of the leds: LED  Color  Label  Description 1  Green   Vin OK  Normally operating  Red  Vin fail  Input voltage out of range 2  Green   Vout ok  RBS internal voltage levels are correct  Red  Vout fail  RBS internal voltage failure 3  Green Control bus busy  Activity on the control bus  Red  Control bus fail  control bus among the modules is in failure  Red blink Control bus fail  Bad message received 4  Green Upload  Firmware upload in progress  Red  Upload fail  Firmware upload failed
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 53    July 2010    8.1.4 DC/DC module The DC/DC module is a continue power voltage converter from an external power source to the internal power level of ECOS-D devices. The converter, other than the power voltage conversion, is able to galvanically insulate (1500Vrms) the internal 13,2 Vdc power distribution from the external power source and a 28 Vdc power distribution to the 110W PA module.      LED  Color  Label  Description 1  Green   Vout OK  Normally operating  Red  NA  2  Green   Vin OK  Normally operating  Red  NA   8.1.5  Radio Receiver and Transmitter module - RTX The “Radio Receiver and Transmitter” (RTX) module is the module that realizes a full duplex radio in the frequency bands commonly used by in the LMR/PMR market (450 - 526 MHz). It is able to operate with channel spacing of 12.5 kHz, 20 kHz and 25 kHz. Limitation on usable RF bands and channel spacing may apply due to local regulations. This module is equipped with devices for numerical computation (DSP, FPGA) and control (microprocessor) combined with the radio receiver front-end and the transmitter driver. The RTX module main functionalities are: •  Dynamic Dual mode radio operations with support of digital and analog modulation  •  Synchronization from external reference via CORE module •  Temperature control. •  UHF band: 450 – 526 MHz
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 54    July 2010    The front panel is provided with bi-color leds to help in troubleshooting the system. The table below describes the meaning of the leds: LED  Color  Label  Description 1  Green  RX busy  RF signal present at the receiver  Red RX fail  Receiver PLL unlock  Red blink RX fail  RX Equalizer failure 2  Green  TX on  RF exciter correctly On Air  Red  TX fail  RF exciter failure: - bad power out - ACP failure - Exciter PLL unlock  Red blink TX fail  TX dynamic equalizer failure 3  Green  Status 1  RF signal with analog modulation present at the receiver  Red RX inhibit  Receiver is in inhibited state 4  Green  Status 2  RF exciter correctly On Air with digital modulation  Red Tx inhibit  Exciter is in inhibited state 5  Green  Status 3  Reserved  Red Data bus fail  The multichannel data bus is out of frame sync 6  Green  Status 4  Reserved  Red  Logic fail  One of the these error is present: - DSP/uP communication failure - logic PLL unlock  Red blink Logic fail  One of the these error is present: - boot failure - EEPROM failure 7  Green  Control bus busy  Activity on the control bus  Red  Control bus fail  control bus among the modules is in failure  Red blink Control bus fail  Bad message received 8  Green  Upload  Firmware upload in progress  Red Upload fail  Firmware upload failed
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 55    July 2010    8.1.6  Power Amplifier module - PA  The “Power Amplifier” (PA) module is a wide band RF amplifier in UHF (450 - 526 MHz). Their time of TX ramp up/down is less than 1200 µsec. This makes the module compatible with the stringent demands of digital transmission. Thanks to a microprocessor mounted on board, the module is able to implement the PUFF technology (Powerful Universal Forming Function) for the shaping of transient power in order to obtain compliance with the rapid transient rules of ACP (Adjacent Channel Power). The microprocessor also manages completely the operation of the module: this would remove any calibration procedures. All configuration changes are performed via software. Other main functionalities are: •  continuous transmitter’s operations (100% duty cycle). •  Output power selectable between two values (Phi and Plo), each of which can be SW set to a nominal value between 10 and 110 Watts.  •  final stage protected against excessive mismatching output power. In the case that VSWR remains above a set threshold (eg ReturnLoss = 5dB) for more than a fixed time, the module is able to send an alert and the output power will not exceed a safety value (eg ≤ 10watt).  •  temperature threshold alarm: if the temperature remains above a set value for more than a fixed time, the module is able to send an alert and will ensure that the RF output power will not exceed a predetermined safe value. The front panel is provided with bi-color leds to help in troubleshooting the system. The table below describes the meaning of the leds: LED  Color  Label  Description 1  Green  PWR High  High Power level selected and correctly On Air   Red PWR fail  Emitted power less than a FW configured threshold (3 dB typical) 2  Green  PWR low  Low Power level selected and correctly On Air  Red VSWR  On Air and VSWR level is greater than FW configured threshold 3  Green  Control bus busy  Activity on the control bus
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 56    July 2010     Red Control bus fail  control bus among the modules is in failure  Red blink Control bus fail  Bad message received 4  Green  Upload  Firmware upload in progress  Red Upload fail  Firmware upload failed
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 57    July 2010    8.2 Power modules maintenance precaution Before maintenance operations involving power supply modules the power cable must be removed.  If the purpose of the maintenance is the replacement of the SWITCH or DC/DC modules the following procedure must be followed: 48 Vdc powered devices: •  Switch off the device moving to the lower position the Main Power and Power switch.      •  unplug the 48Vdc D-SUB 3W3 connector   •  Remove the module as described in section 8.1.63. 48 VDC input Power on/off switchMain Power on/off switch
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 58    July 2010    8.3 Module removal To remove a module from the RBS follows the procedure described below. 1 – Unscrew the two (or four) screws marked in red on the front panel of the module   2 – From the front side of the RBS using the handle marked in blue pull the module out.     Module locking screws Module handles
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 59    July 2010    8.4 Back card removal To remove a back card from the RBS follows the procedure described below. 1 – Unlock the two (or four) knobs marked in red on the panel of the back card  2 – From the rear side of the RBS using the same knobs pull the back card out.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 60    July 2010    8.5 Local Maintenance Interface The local maintenance interface is located on the front panel of the RBS on the CORE module.  To perform local Maintenance and local configuration of the RBS, connect a PC to this connector using the appropriate LAN adapter.  Maintenance LAN Adapter  Local Maintenance Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 61    July 2010    D-SUB HD 15 female pinout PIN   Mean 1   not used 2   not used 3   not used 4   not used 5  TX-  Transmit Data - 6   not used 7  RX-  Receive Data - 8   not used 9  TX+  Transmit Data + 10   not used 11   not used 12  RX+  Receive Data + 13 DGND Digital Ground 14  FLP  Front LAN Presence 15   not used  (soldering side view)  LAN RJ45 female pinout PIN    1  RX+ Receive Data + 2  RX-  Receive Data - 3  TX+ Transmit Data + 4   not used 5   not used 6  TX-  Transmit Data - 7   not used 8   not used
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 62    July 2010    8.6 Local Test AF Interface The local Audio Frequency interface is located on the front panel of the RBS on the CORE module. Use this interface to test the AF performance of the RBS.  Interconnecting points  Type of connector terminatingthe cable Type of cable/conductor Microphone  Male type D high density connector with 15 pins  Section of each wire ≤ 1 sq.mm. (AWG 18)  Local Maintenance Interface
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 63    July 2010    D-SUB HD 15 female pinout PIN   Mean 1 GND  Ground 2  AF FO  Audio Frequency Output (no volume)3   not used 4  AF out -  Audio Frequency output from RBS 5   not used 6  AF in  Audio Frequency input to RBS 7   not used 8   not used 9   not used 10  AF out +  Audio Frequency output from RBS 11  PTT  Push To Talk input to RBS 12   not used 13 DGND  Digital Ground 14   not used 15 VDD    (soldering side view)  8.7 Remote Maintenance Interface The Remote maintenance interface may be accessible directly or not on each RBS depending on the configuration of the system. If the RBS is configured to be remotely controlled via the LAN interface, see the LAN interface section to correctly connect the RBS. For more information about the remote maintenance procedure see the Network Management System (NMS) Manual, where supplied.
 SELEX Communications  Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing 64    July 2010                                 Information contained in this document may not be used, applied or reproduced for any purpose unless agreed by SELEX Communications S.p.A. in writing. SELEX Communications S.p.A. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. SELEX Communications logo is a trademark of SELEX Communications S.p.A. Printed in Italy. © SELEX Communications S.p.A. All Rights reserved.

Navigation menu