Sebury Technology W3-H ACCESS CONTROL User Manual

Sebury Technology Co., Ltd. ACCESS CONTROL Users Manual

Users Manual

User  Manual.8. .10.D0 D0D1 D1ALARM-OPEND_IN DC /3A12VW3-HDoor d etecti ng switch--++-+Special Power Su pplyAlarmGNDAC&DCAC&DCNCCOMNONC COM NO +1 2V GN DV+GNDOPE NGreenWhiteGreyYell owBrownRedBlackBluePurpleOrangePinkExit buttonWiegand reade rFail -Secu re lockFai l-Sec ure lockFigu re 2Transmission Format:1: Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code.Format:  PIN Code ( any 4-8 digits between 0000-99999999)Example: PIN code:111111Press 111111 #, then the output format will be: 0000111111(l  2: Proximity Card Transmission The Reader will transmit the card data when it reads the Card.Format: Card Number(Note: No matter the card is valid or invalid, the data will be transmitted)l  Note: if press an invalid PIN (any 4-8 digits), the data will be also transmitted.)14.2  W3-H operating as a ControllerIn  this  mode  the  W3-H  supports  a  Wiegand  26-37  bit  input  so  an  external  Wiegand device with a 26-37 bit output can be connected to the Wiegand input terminals on the W3-H.  Either  an  ID  card  reader  (125KHz)  or  an  IC  card  reader  (13.56MHz)  can  be connected to the W3-H. Cards are required to be added at the external reader, except where an external HID reader is used, in this case cards can be added at either reader or controller. See figure 2.D0D1ALARM-OPEND_INW3-HGNDAC&DCAC&DCNCCOMNOControllerV+V+GNDGNDD0D1PowerGreenWhiteGreyYellowBrownRedBlackBluePurpleOrangePinkFigure 1W3-H Quick Reference Programming GuideTo enter the programming mode *  Master code   #888888 is the default factory master code To exit from the programming mode *Note that to undertake the following programming the master user must be logged inTo change the master code 0    New code    #   New code   #The master code can be 6 digits long1    User ID number    #   PIN    # The ID number is any number between 1-2,000. The PIN is any 4-8 digits between 0000 - 99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming modeTo add a PIN user1   Read Card    #Cards can be added continuously without exiting from programming modeTo add a Card userTo delete a PIN or a Card user 2    User ID number   #  for a PIN user or2    Read Card   #  for a card userTo unlock the doorTo unlock the door for a PIN userTo unlock the door for a card userEnter the  PIN  then press   #Present the card .7.To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselvesTo change a PIN in card and PIN mode (Method 2) Note that this is done out  programming mode so the user can undertake this themselvesside To delete a Card and PIN user just delete the card *  Read Card  Old PIN #   New PIN #   New PIN #*   ID number #  Old PIN #   New PIN #  New PIN #2  User ID   #.9.To set keypad tone 7   8   #   To disable the keypad tone      7   9   #   To enable the keypad tone(Factory default) To set LED 7   6   #   To disable the red LED        7   7   #    To enable the red LED(Factory default) 13. Wiegand Mode SettingW3-H supports Wiegand 26-37, both input and output. It can be used as a reader or controller.To set Wiegand format: 9  26-37  #   (Default setting: Wiegand 26)14. Interconnecting Two Devices14.1 W3-H operating as a Wiegand Output ReaderIn this mode the W3-H supports a Wiegand 26-37 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26-37 bit input. See figure 1.To set Duress PIN user12. Duress User SettingsThere are 10 groups Duress PIN/card available. When input Duress PIN/card, the door will open, at the same time, the output alarm operates.To add a PIN userTo delete a PIN user2 To set Dur ss card usereTo add a card userTo delete a card user(The ID number is any number between 2001 2010)-Note: ① User ID number must be any 4digits between 2001 2010② Duress PIN/card must be unique, should be distinguished from common PIN and card(When the Duress PIN/card is the same with common PIN and card, they will become invalid in Duress, and worked as common user function)-(The ID number is any number between 2001-2010)2 To remove the alarmTo reset the Door Forced Open warning Read Valid Card or Master Code #To reset the Door Open Too Long warning Close the door or  Read Valid Card or  Master Code #W3-H Waterproof Keypad/Reader/Controller1. Packing listNameDigital Keypad W3-HQuantity RemarkScrew DriverRubber  BungsSelf Tapping ScrewsDiode1    4416*27mm, used for fixing4*28mm, used for fixingIN4004User Manual 11Please ensure that all the above contents are correct. If any are missing please notify the supplier of the W3-H. .1.Manager Card 2Manager Add Card & Manager Delete CardThe W3-H is a single door multifunction access control with HID card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof zinc alloy electroplated case. The electronics are fully potted so the W3-H is waterproof and conforms to IP68. The W3-H supports up to 2,000 users in either a Card, 4-8 digits PIN, or a Card + PIN option and additional 10 groups Duress PIN/Card. The built-in card reader supports HID 125KHz frequency cards/tags. The W3-H has many extra features including Duress PIN/card, block enrollment, Wiegand 26-37 bits interface, and backlight keypad…etc. These features make W3-H an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.2. Description Waterproof, conforms to IP 68 Strong zinc alloy electroplated anti-vandal caseFull programming from the keypad2,000 users, supports Card, PIN, Card + PIN 10 groups Duress PIN/CardCard interface: HID 125KHz CardCan be used as a standalone keypad, PIN length 4-8 digitsPulse mode, Toggle model  l  l  l  l  l  l  l  3. Features.2.PCB connect diagramAnt i-dem oliti on alar mD0D1ALARM-OPEND_INGNDAC&DCAC&DCNCCOMNOJ1D0D1ALA RM-OPE ND_I NGNDAC& DCAC& DCNCCOMNOJ1W3-H5. Installationl l l l l Remove the back cover from the keypad using the supplied security screwdriverDrill 4 holes on the wall for the screws and 1 hole for the cableFix the back cover firmly on the wall with 4 flat head screwsThread the cable through the cable holeAttach the keypad to the back cover.3.4. SpecificationsOperating Voltage 12-24V DC or 1 -18V AC22,000  (Additional10 groups Duress PIN/Card)Adjustable Door Relay TimeAdjustable Alarm TimeWiegand InterfaceWiring ConnectionsWiegand 26-37 input & outputL128 X W82 X H28mm600 g700 g12 keys: 3 X 4 digitsOperating Humidity DimensionsNet Weight Gross Weight10%-90% RH1-99 secondsElectric Lock,  Exit Button,  DOTL, External AlarmOperating Temperature -20-50HID 125KHz card3-6 cmMax 2AMax 20AUser CapacityKeypadCard TypeCard Reading DistanceLock Output Load Alarm Output LoadActive CurrentIdle Current≥65mA≥35mAEnvironment Conforms to IP680-3 minutes6. WiringColourGreyYellowBrownRedBlackBluePurpleFunctionD0Alarm -OPEND-IN 12-24V DC or 12-18V AC NOCOMDescriptionWiegand Output D0White Wiegand Output D1 Request to Exit ButtonDoor Contact 12-24V DC or 12-18V AC Regulated Power Input 12-24V DC or 12-18V AC Regulated Power InputAlarm Negative Orange NCPink GNDGreenD1Relay NO Relay COMRelay NCW3-H Negative 12-24V DC or 12-18V AC .4.The relay on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines….etc) Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for the pre-set relay pulse time.Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again.8. Relay operation (Pulse mode and Toggle mode)9.  To Reset to Factory DefaultTo reset to factory default, power off, press     , hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two HID cards, the LED will turn in red, means reset to factory default setting successfully. Of the two HID cards read, the first one is Manager Add Card, the second one is Manager Delete Card.Remarks: Reset to factory default, the user's information is still retained. *7. Anti Tamper AlarmThe W3-H uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. .5. .6.10. Sound and Light IndicationOperation StatusPower onOperation successfulOperation failedEnter into programming modeRed Light---BrightBrightBrightGreen Light--Bright---BuzzerShort Ring-Short RingShort Ring3 Short RingShort Ring-Short RingPress keypad--Stand byIn the programming modeExit from the programming modeOpen the doorBright-Bright Alarm-AlarmBright-Short RingYellow Light-----Bright----11. W3-H Detailed Programming Guide 11.1 User SettingsTo exit from the programming modeTo change the master codeset valid card only usersset valid card and PIN usersset valid card or PIN users*     Master code     # 888888 is the default factory master codeTo enter the programming mode*     Note that to undertake the following programming the master user must be logged in0   New code    #   New code    #The master code is any 6 digitsSetting the working mode:3 0 #3 1 #3 2 # Entry by either Card or PIN (default)Entry by Card onlyEntry by Card and PIN togetherTo set a user in either card or PIN mode   (  3   2   #  )    (Default setting)To add a PIN user 1  User ID number   #   PIN   # The ID number is any number between 1- 2000. The PIN is any 4-8 digits between 0000 -99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1   User ID No 1   #   PIN   #  User ID No 2   #   PIN   #To delete a PIN user  2  User ID number  #  Users  can  be  deleted  continuously  without exiting programming modeTo delete card user by card Note users can be deleted continuously without exiting from programming mode2   Read Card    #  To delete a card user by user ID This option can be used when a user has lost their card2   User ID   #  To add a card user (Method 3)Add a series cards users - BlockEnrollment5  ID number   #  The 1st Card number   # Card quantity  # Note that cards must be consecutive, and cardquantity is between 1-2000Maximum 2,000 cards can be enrolled at a stretch within 2 minutesTo delete   card user by card number Users can be deleted continuously without exiting from programming modea2   Card number   #  To set a card and PIN user in card and PIN mode (   3   1   #   )To Add a card and PIN user(The PIN is any 4-8 digits between 0000 - 99999999 with the exception of 1234 which is reserved)Add the card as for a card user Press    to exit from the programming modeThen allocate the card a PIN as follows:    Read Card    1234 #   PIN #   PIN #*  *To change the PIN of a PIN user (This step must be done out of programming mode)To add a card user (Method 1)This is a fastest way to add cards using ID number auto generationTo add a card user (Method 2)Th is i s t he opti o na l way to a dd cards using User ID Allocation. In this method a User ID is allocatedto a card. Only one user ID can beallocated to a single card       ID number #    Old PIN #    New PIN #     New PIN #*1    ID number   #   Card   #1   Read Card    #  Cards can be added continuously without exiting programming model  l  l  l  Wiegand 26-37 input & outputOne programmable relay output, NO, NC, COMAdjustable door output time, alarm time, door open time Card block enrollmentl  l  l  l  l  l  l  With Manager Cards for adding or deleting card user easilyBacklight keypadBuilt in light dependent resistor (LDR) for anti tamperBuilt in buzzerRed, Yellow and Green LED display the working status12-24V DC or 12-18V ACTwo-year warrantyW3-HD0D1ALARM-OPEND_IN DC /3A12V-+Wiega nd D0Wiega nd D1GNDAC&DCAC&DCNCCOMNONC COM NO +12V GN D OPENGreenWhiteGreyYellowBrownRedBlackBluePurpleOrangePinkDoor detec ting sw itchExit bu tto nAlarmPower+-+-Fail-secure lockAlarm“-”Special Power SupplyConnection GiagramTo add Card User by Manager Add CardTo set card users by Manager cardTo delete Card User by Manager Delete CardManager add card  Read User card Manager add card  Cards can be added continuouslyManager delete card  Read User Card  Manager delete cardCards can be deleted continuouslyFor a PIN user Enter the PIN  then press #For a card user Read cardFor a card and PIN user Read card then enter PIN #To unlock the doorTo Add and Delete a card userTo delete All usersTo delete ALL users Note that this is a dangerous optionso use with careThe operating is the same as adding and deleting a card user in 3   2   #2   0000   #To set a card user in card mode         (  3    0   #   )Common Power SupplyD0D1ALARM-OPEND_INExit buttonW3-H-+GreenWhiteGreyYellowBrownRedBlackBluePurpleOrangePowerAlarmGNDAC&DCAC&DCNCCOMNOPink-+LockIn4004Power“+”Electric bolt:NCElectric strike:NOPower“+”Alarm  -“ ”Door detecting switch12-24V DC or 12-18V AC/3ANotes:Connect the negative pole of the lock to NC is for Fail safe lock.Connect the negative pole of the lock to NO is for Fail-secure lock. Keypad LockoutAlarm OutputNormal status: No keypad lockoutor alarm 7   0   #    (Factory default) 7   1   #  7   2   # Keypad  Lockout  &  Alarm  Output  options.  If  there  are  10  invalid  cards  or  10 incorrect  PIN  numbers  in  a  10  minute  period  either  the  keypad  will  lockout  for  10 minutes or the alarm  will  operate  for 10 minutes, depending  on the option selected below.Light and Sound SettingTo set the alarm output time (0-3 minutes). Factory default is 1 minuteAlarm output time9   0-3   #To disable door open detectionDoor Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is open by , or if the door is opened after 20 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute.  forceTo enable door open detection  6   1   # 11.3   Alarm, Sound and Light SettingsDoor Detection, To set keypad backlight 7   4   #    7   5   #   To enable keypad backlight(Factory default) Toggle modeToggle mode 4   0   #Pulse mode(Door relay time setting)Pulse mode(Factory default)11.2  Relay Setting (Pulse mode,Toggle mode)4   1-99   #The door relay time is between 1-99 seconds,the factory default setting is 5 seconds. 6   0   #  (Factory default )To disable keypad backlight
 FCC WARNING  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Navigation menu