PIR MOTION DETECTOR    INTRODUCTION The PIR-3SP Passive Infrared Detector detects the movement of human body heat within its effective coverage; thus, when an intruder crosses or enters the area, the resulting change in infrared energy from the intruder will be detected and an alarm signal will transmit to the Base Unit.              PET IMMUNE DETECTOR  This detector is immune to one domestic pet up to 18 kg or 60 cm moving on the floor.    If animal activity takes place above 1 meter high, the pet immunity allowance will be significantly reduced. Therefore Do Not aim the detector at stairways that animal can pass.  This detector should be mounted on the wall or corner at 2.0 m high and perpendicular to the floor.  Please  note  under  this  condition,  the  human  motion  within  1  m  from  the  detector  is undetectable.  Do  NOT  use  any  mounting  bracket with  swivel  adjustment.  Should  you  must  use  a  bracket,  it should be used for horizontal alignment only, do not tilt down.  Place the PCB at the “0” scale position. (for PCB version ST-IR-3B, or “P” scale for ST-IR-3A).     And jumper JP5 at “PET” position.  It’s a must to verify the pet immune function after installation. In case animal is detected, sliding the PCB to +1~+2 scale to test again (for PCB version ST-IR-3B, or to -1~0 scale for ST-IR-3A).  The weight of the animal can only be used as a reference. Other factors such as height and color of fur could also affect the level of immunity.   IMPORTANT NOTE     To  get  the  best  sensitivity,  PIR  should  be  mounted  to  detect movement  of  the  intruder  across  a  room  rather  than  toward  the detector.   AAA Battery X 2 Tamper Switch  LED ON/OFF Jumper Pulse Count Jumper Test Switch Reed Switch PCB Scale  Infrared Sensor (Don’t touch) PCB Fixing Screw Jumper JP5 1 Fig. 1
Do  not  install  where  the  detector  faces  a  window,  since movement outside could cause unwanted alarms.    Make sure the detection area does not have obstructions (curtains, screens, large pieces of furniture, plants, etc.) that could block the pattern of coverage.    Avoid  placing  the  sensor  in  areas  containing  objects  likely  to produce  a  rapid  change  in  temperature,  such  as  central  heating radiators or ducts (or heaters of any kind), air conditioners, open flame, etc.                        INSTALLATION 1. Refer to FIG. 2, and loosen the screw on the PIR bottom, and then remove the front cover.   2. Insert  two  AAA  alkaline  batteries.  Select  “Installer  Mode”  on  the  Base  Unit  and  enter  the Installer  Code  to  gain  access  authority.  Then  select  \Set  Device\Enroll  Device\Burglar Sensor\Enter Zone No.  to enroll the  ID  of  PIR-3SP  by pressing  its  TEST button  on  the PIR board. You may change its various attributes under \Set Device\Change Device Setting\Burglar Sensor Change, to fulfill different requirements.   Important  Notice:  In  order  to  reset  the  microprocessor  properly,  before  replacing  the batteries in the PIR-3SP, press the TEST button for 5 seconds to discharge the energy that remains in the capacitor on the PC board. Otherwise, it may not restart.   3. After power on, wait one minute for sensor warm-up. 4. Mount  the  base  with  two  screws  (refer  to  Fig.  4)  or  use  Velcro  tab  provided  at  a  selected location, and 2 m above the floor. Make sure the distance between PIR and Base Unit is within RF transmission range.  $  Fig. 2 Screw Holes Fig. 3  Open Test Button Simulation ON OFF Fig. 4 Fig. 5 2
WALK TEST It is essential to perform a walk test to verify optimum detection coverage. To do this, first hold the “TEST” button on the PIR-3SP board down for at least 3 seconds, until the LED turns ON→OFF→ON, then release the button. Afterward, the PIR-3SP enters “TEST” mode for 3 minutes. Replace the cover of the PIR-3SP, then walk into the detection area at normal speed, while observing the LED indicator. The LED stays ON normally, and turns OFF when motion is detected. If the detection pattern is not satisfactory, re-aiming the detector or adjusting the vertical pattern by sliding the PIR board to -1 or 0 scale to test again.   Notes: 1. For the sake of convenience, the PIR is built in a reed switch;    refer to its location on   Fig. 1. You may use a magnet to simulate the function of TEST button without opening the  case.  When  a  magnet  is  placed  close  to  the  reed  switch,  the  PIR  responses  as  the TEST  button  is  pressed;  refer  to  Fig.  5.  And  when  a  magnet  is  removed,  the  PIR responses as the TEST button is released.         2. Test mode can be terminated before the 3-minute timeout by pressing the “TEST” button again (or use a magnet to approach for a second) until the LED turns OFF. Afterward, it returns to NORMAL mode. 3.  In  NORMAL  mode,  the  PIR-3SP  activates  the  transmitter  when  it  initially  detects movement, then disables itself. The unit will resume operation only after about 3 minutes with no further detection of movement. In other words, if installed in a heavy traffic area, the  PIR-3SP  will  not  transmit  until  the  area  has  been  evacuated  for  3  minutes.  The purpose of this feature is to reduce power consumption and prolong battery life.  RADIO LINK TEST Open  the  top  cover  of  the  PIR-3SP  and  press  the  TEST  button  on  the  PC  Board,  or  use  a magnet to activate the reed switch, to see whether the Base Unit can receive the radio signal.  PULSE COUNT SELECTION The  PIR-3SP  is  equipped  with  a  programmable  pulse  counter  that  can  be  set  by  placing  the jumper on the desired setting (2 or 4). The PIR-3SP automatically overrides to one-pulse mode while in "TEST" mode. 2 pulses: This setting has high sensitivity of detection. Two pulses should be selected when the detection range is longer (over 5 m) 4 pulses: Alarm signal will only be sent if 4 pulses are detected within approximately 1 minute. This setting provides the maximum protection against false alarms caused by all types of environmental disturbances.  LED ON/OFF SELECTION To prevent the PIR from being discovered by an intruder, LED can be disabled by putting LED ON/OFF  jumper  at  OFF  position.  Nevertheless,  the  LED  is  enabled  automatically  when  the PIR-3SP is in “TEST” mode, even with the jumper at the OFF position. 3
DETECTION PATTERN (PIR-3SP)                            SPECIFICATIONS Detector Type: dual element Coverage Angle: 110o Pet-immunity: Up to 18kg, 60cm high Effective Distance: max. 12 m @ ambient temp. 25℃ RFI Immunity: Ave. 20V/m (10~10000MHZ) Detectable Speed: 0.3~1.5m/sec. RF: 915Mhz, less than 10mW Power: two AAA alkaline batteries Current: 10uA @ standby, 12mA @ activation Estimated Battery Life: 2 years (@ actuated 40 times/day)     Pulse Count: 2 or 4 pulses selectable Mounting height: typical 2 m Working Temperature : 0℃~40℃ Humidity: max. 95% RH   Size: 112 x 66 x 45 mm Weight (w/o battery): about 90g  Note: This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no grantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help.   110°Top ViewSide View2m 0.6m 1m          8m                    12m
 APPENDIX The  PIR-3SP  can  be  used  as  a  conventional  detector  (non  pet-immune)  if  changing  lens  to  LN-N type (refer to Fig 6). And the model no. becomes PIR-3S. Note: 1. When you use LN-N lens, you must place JP5 at “NORL” position. 2. The detection patter of  PIR-3S is  as below  (max.  distance  15m), and you may  adjust PCB scale position to  fit  detection  coverage,  or  use bracket  IRB-3  to  adjust detection  coverage. Besides, you may change the installation height properly.      DETECTION PATTERN (PIR-3S)         Fig. 6 110°Top ViewSide View2.3m1m 2.5m         8m             15m4