Users Manual 2

  Page 15© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualSERIAL INTERFACEDiagsInC6100pR1100RC7100pDiagsOut+3V3C1100nC2100nC3100nC4100nC5100nRadio PIN 7Radio PIN 8Radio PIN 24SYSTEM RS232nPTTM1M2P11P22P33P44P55P66P88J1J2J3J4J5J6J7J8P77X1C1+2C1-4C2+5C2-6Vs+ 3Vs- 7VCC 17GND16T1in12 T1out 15T2in11 T2out 8R1out13 R1in 14R2out10 R2in 9nEN1nSHDN20U1MAX3222E C10100pR4100RC11100pC8100pR2100RC9100pR33K3+3V3note: Radio inputs are 5V tolerant, however 3V3 is recommended.Optional EMC componentsSystem Port Interface
  Page 16© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualPower Supply Filtering
  Page 17© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualPart G – Mounting and LED IndicatorsMounting & Connector Information  Please Note : Mating connectors can be supplied with each radio or seperately. Please order as part number SM%CO2241-20X2
  Page 18© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualAntenna Port Cabling (Hazardous Installations)When the O Series OEM module is intended to be used in equipment which is compliant with Class I, Division 2 - Groups A,B,C,D Hazardous Locations, the antenna conenctors need to be retained using a soldered connection as shown in the diagrams below. The method of soldered retention will depend on the model of O Series OEM product in use. See below for model specifi c guidlines.For O Series modules that have integtel mounting tabs, solder the TAB to the RF connector. For O Series modules that have no TAB, solder a wire from the shield lid to the connector.
  Page 19© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualLED IndicatorsIndicatorsLegend   Power LEDTx Power (Red) / DC Power (Green)   Sync/NoRx LEDMasters:100ms pulse when user data received (Green)Remotes/Bridges:Pulsed every 1500ms for 100ms when master acquired, additional 100ms pulse when user data received (Green)Pulsed every 1500ms for 100ms when master not acquired (Red)   Port A ActivityPulsed for 100ms for any TxD activity on Port A TXD (Red)Pulsed for 100ms for any RxD activity on Port A RXD (Green)   Port B ActivityPulsed for 100ms for any TxD activity on Port BA TXD (Red)Pulsed for 100ms for any RxD activity on Port B RXD (Green)Product LabellingWhen this OEM module is housed inside another unit, the unit must be labelled with the following notice :“This unit contains a device with FCC ID: 900MHz Modules:NI8OM900 and IC: 4630A-OM900.2.4GHz Modules:NI8OM240 and IC: 4630A-OM240.This device complies with part 15 of the FCC rules. Operation of this device is subject to the following conditions:(1) this device may not cause harmful interference, and (2) this must accept any interference received, including interference that may cause any undesired operation.”
  Page 20© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualPart H – Programming and DiagnosticsProgrammingThe O Series OEM module is programmed via the System Port. There are two methods of programming:(a) In Situ : Programming via the 3-wire System Port pins(b) In K-Series : OEM Module can be plugged into a K Series carrier PCB and programmed via the System Port on the K Series. The O Series OEM module is programmed using the TVIEW+ Management Suite : K Series programmer. Programming of the O Series is similar to the K Series - however some features are optional on the O-Series (dependent on external support circuitry). The features that require external support circuitry which may or may not be relavent to your design are:(a) RS-485 . (b) Multi-master Synchronisation. (c) RSSI Output(d) Port B(a) Port A & B Hardware handshaking signalsFor a comprehensive guide to programming the O Series OEM module, please refer to the TVIEW+ K Series User Manual - Part G.DiagnosticsThe O Series OEM module includes diagnostics which is useful for fault fi nding and system commisioning. Detailed information about O Series diagnostics is available in the TVIEW+ Diagnostics User Manual. TVIEW+ Diagnostics is available via the System Port of the O Series module. To access the diagnostics facilities locally, the System Port of the O Series must be brought out to a connector for connecion to the computer running the diagnostics package. Alternatively, remote diagnostics connectivity is available “over-the-air”. More information on confi guring diagnostics can be found in both the TVIEW+ Diagnostics User Manual and the K Series User Manual. The OEM user may also wish to integrate O Series diagnostics into their own application. To facilitate this, Trio Datacom can provide the specifi cations document for the “Remote Diagnostics Protocol”. This document specifi es how diagnostics messages are constructed and what facilities are available. To obtain this document, please contact the factory on support@triodatacom.com.
  Page 21© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualPart I – K Series PCB Overlay & Schematics1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.3 9K-Series  Block  DiagramD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-Block.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 D2007+5V +3.3V+5V +3.3VGP  INPUTGP  OUTPUTINPUTINPUT INPUTFILTERFILTER FILTERCROWBARCIRCUIT(10-30V)to  5V 5V  to  3.3VREGULATORREGULATORLINK LINKLINKFIELDS FIELDSFIELDSRS-232RS-232 RS-232/RS-485DRIVERSDRIVERSDRIVERSSHUTDOWNSIOSYSTEM PORTPORT APORT BO-SERIES  MODULETEMPERATURESENSOR NVRAMFACTORYDEFAULTSSWITCHI2C  BUS10-30v(U1) (U2)(Q2)(FL1)(U7) (U7) (U9)(U6)(U4) (U5)RSSI(X7) (X10) (X6) (X8)(X5)LINKFIELDS(X4)SW1(X11) (X2)(X1)(X9)Schematics
  Page 22© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User Manual1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.5 9K-Series  PSUD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-PSU.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 DC39100pkeep  separated  !R291KTP2POWER  INPUT(10~30VDC)VSWFBVINSWVIN+VIN-POWER  SUPPLIESInput  Filter  &  ProtectionStep-Down  SwitcherR341KR302K2R3210KVINFR331K13 2Q1BC857WR37220RSCRgateVset (Total  ESR  =  100mOHM)C491uTP1R3110K(ESR  =  65mOHM  per  cap)C43220nC44100uC45100u2007IN3FB 7IN2VSW 13CB 4GND9VSW 14EN8VSW 12DAPnc5nc6nc1nc11nc10DAPU1LM2676SD-ADJSUPPLY-MONITOR+5V213 4256BPSGCBCGFL1BNX012-01D3SMCJ33A3 12U3LM431AKD1SS26A KD2SS26C3510nR27NF  (68K)R283K3231Q2MCR708AT4G12X3F13AL122uHL247uHR5215KR531KENABLE+3V3AKD12SS26R22NF  (0R0) TP3TP412 3D13BAV99W12 3D14BAV99W12 3D15BAV99W12 3D16BAV99WC671nHIGH=ENABLEC110uC210uVIN3GND2VOUT 1U2LP38690DT-3.3+5V2-MODC36FT22nC4056u  35VC4156u  35VC42NF  (56u  35V)C751000u  6.3VC661000u  6.3V
  Page 23© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User Manual1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.6 9K-Series  RF  ModuleD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-RadioModule.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 DR5 220RR9 220RR6 220RR8 220RMULTISYNC-INPUTR10 220RR12 220RR11 220RR7 220RPORTB-RXDPORTB-CTSPORTB-TXDPORTB-RTSnSHUTDOWN-INPORTB-DCDRSSI-OUTPTT2007Tx-INHIBITMODULE-DIAGS-SER-INMODULE-DIAGS-SER-OUTPORTB-DTRR17 220RR15 220RMODULE-Rx-SYNC-LEDMODULE-Tx-LEDMODULE-DC-POW-LED+3V3L4FB8530Radio  ModuleMULTISYNC-OUTPUTL3FB8530+5V2-MODC5100nC8100nC610uC710uR16 220RR4220RR18 220RR20 220RR19 220RR14 220RPORTA-RXDPORTA-CTSPORTA-TXDPORTA-RTSPORTA-DCDPORTA-DTRnSHUTDOWN-OUTSUPPLY-MONITOR+3V3Restore  DefaultsSDA1SCL2OS3GND4A2 5A1 6A0 7VCC 8U4NF  (LM75A) +3V3C9100nR1220RR2220RPORTB-RXD-LEDMODULE-RX-SIG-LEDPORTB-TXD-LEDPORTA-TXD-LEDPORTA-RXD-LEDSDA 5SCL 6WP 7GND4NC3NC2NC1VCC 8U524LC01+3V3C69100nGP-INPUTNVRAMTEMPERATURESENSOR1 23 4SW1SKQLLA1 23D18BAV99W12 3D19BAV99WTEST-MODEPORT2-RxD 2PORT2-TxD 1PORT2-DCD 9PORT2-DTR 5PORT2-RTS 4PORT2-CTS 3PORT0-SysSerOut8PORT0-SysSerIn7VCC 6PAVCC 10PAVCC 12GND11GND14HOP-SYNC-INPUT 27RxD-PORT2-LED21ANALOG-RSSI 13Tx-LED15 SYNC-LED17ANALOGUE-INPUT16TxD-PORT1-LED18RxD-PORT1-LED19DC-POW-LED22nFACT/TEST-MODE23PTT24Tx-INHIBIT 25SHUTDOWN-IN 26HOP-SYNC-OUTPUT 28PORT1-TxD29 PORT1-RxD30 PORT1-RTS31 PORT1-CTS32 PORT1-DTR33 PORT1-DCD34TWD35 TWCK36 SUPPLY-MONITOR37 SHUTDOWN-OUT38 RxSIG-LED39 NVRAM-WP40TxD-PORT2-LED20X9R2110KNVRAM-WPC3FT22nC4FT22nR34K7R1074K7 C81100n
  Page 24© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User Manual1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.8 9K-Series  RS-232  Port  BD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-RS232PORTB.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 DPORT  B  RS232  SERIAL  INTERFACEC23100pR35100RC24100pC25100pR38100RC26100pC27100pR40100RC28100pCTS-BRTS-BDSR-BC12100pR23100RC13100pC15100pR24100RC16100pC19100pR25100RC20100pC21100pR26100RC22100pDTR-BRXD-BTXD-BDCD-B+3V3PORTB-RXDPORTB-TXDPORTB-DTRPORTB-CTSPORTB-RTS2007R45NF  (10K)R43NF  (22K)+5V2GP-INPUTC10100nC11100nC14100nC17100nC18100n1 23D4NF  (BAV99W)12354U8LMV321IDCKRR3947K+3V3PORTB-DCDC1+10C1-12C2+13C2-14V+ 11V- 15VCC 9T1-IN7T1-OUT 2T2-IN6T2-OUT 3R1-OUT5R1-IN 4R2-OUT17 R2-IN 16GND8R2-OUT22 R2-IN 23T1-IN18 T1-OUT 1T2-IN19 T2-OUT 24T1-IN21 T1-OUT 20U6ICL3207IAZUser-OutRSSI-OUTC70100nR92NF  (100R)A KD17NF  (SMBJ24A)MULTISYNC-INPUTR691K8R703K3R663K9R6039KR7215KR7515K+5V2R61100R+5V2MULTISYNC-OUTPUTC64100p 132Q5BC817W13 2Q4BC857W1 23D11BAV99W13 24Q6NF  (BSP-295)C29NF  (1n)C73NFC74NFC711nC681nR77220KR36470KR90NF  (47K)R4147KR4247K162738495M2 M1X412354U10NF  (LMV321IDCKR)+3V3132Q9BC817WR853K9R1063K3R1002K21 23D20BAV99WR992K2R105270R+5V2R104270RR103270RR102270RR101270R1 23 45 67 8X11HDR4X2C80100pGPSMultisyncGP-OutUser-RSSI
  Page 25© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User Manual1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.7 9K-Series  RS-232  System  Port  and  Port  AD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-RS232SYSTEM-PORTA.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 DSERIAL  INTERFACER73100RC63100pnShutdownDiagsInC59100pR55100RC60100pC62100pTxInhibitDiagsOut+3V3Tx-INHIBITENABLE2007nSHUTDOWN-OUTnSHUTDOWN-INC32100nC33100nC38100nC46100nC47100nC1+10C1-12C2+13C2-14V+ 11V- 15VCC 9T1-IN7T1-OUT 2T2-IN6T2-OUT 3R1-OUT5R1-IN 4R2-OUT17 R2-IN 16GND8R2-OUT22 R2-IN 23T1-IN18 T1-OUT 1T2-IN19 T2-OUT 24T1-IN21 T1-OUT 20U7ICL3207IAZ1 23D7NF  (BAV99W)1 23D6NF  (BAV99W)1 23D9NF  (BAV99W)R62NF  (22K)R65NF  (22K)R7622KR63NF  (22K)R74470R+3V3C53100pR50100RC54100pC55100pR51100RC56100pC57100pR54100RC58100pC30100pR46100RC31100pC48100pR48100RC50100pCTS-ARTS-ADSR-ADTR-ARXD-ATXD-ADCD-APORTA-DCDPORTA-RXDPORTA-TXDPORTA-DTRPORTA-CTSPORTA-RTS1 23D5BAV99W1 23D8BAV99W1 23D10BAV99W132Q3BC817W+3V3+3V3R5622KR6722KR5722KR5922KR6822KMODULE-DIAGS-SER-INMODULE-DIAGS-SER-OUTPTTC61100pPORTA-RXDRS485-TXDPORTA-DCDRS-485RS-232C34100pR47100RC37100pC51100pR49100RC52100pPORT  AR9110KC72100n+5V2PORTA-DCDPORTA-RXDRS485-TXDRS-485RS-232RS-485RS-232RS-485RS-232C65220nR134K7SERIAL  INTERFACESYSTEM  RS232TermUntermR93100RR94100RR95100RR96100RC76NFC77NFC78NFC79NFR780R0R790R0123X10123X7123X6123X8123X1313 2Q7BC857WR9822KR9747K+3V3nPTT+12V  on  E-SeriesTEST-MODER713K3R583K3+3V3M1M2P11P22P33P44P55P66P88J1J2J3J4J5J6J7J8P77X2M1M2P11P22P33P44P55P66P88J1J2J3J4J5J6J7J8P77X1VCC 8DI4A/Y 6RO1RE2GND5DE3B/Z 7U9ISL8485IBZ-TR441K+5V21 23D21BAV99W132Q10BC817W13 2Q11BC857W+3V3 R10822KR109NF  (47K)SPTxPARxSPRxPATx1 2LK2LK-SOLDER-1WAY-BRIDGEDLK1TP5NF  (TP-100)TP6NF  (TP-100)
  Page 26© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User Manual1122334455667788D DC CB BA ATRIO  DATACOM  Pty.  Ltd.41  Aster  Avenue.ISSUE CHANGE  DETAILS DRAWN DATEECO  No.9 9K-Series  Status  LEDsD1TITLE:SIZEA3DATE:SHT: OFFILE:CHKD:DWG  No.:195-00-100-StatusLEDs.SchDoc11-Jul-07REV:195-00-100THIS  DRAWING  IS  CONFIDENTIAL  INFORMATIONDisclosure  of  this  information,  whether  all  or  part  thereof,  cannot  be  made  to  a  3rd  party  without  the  written  consent  of  Trio  Datacom   Pty.  Ltd.    Trio  Datacom  Pty.  Ltd.  reserves  the  right  to  change  documentation  in  the  light  of  technical  advancement.COPYRIGHTCPCB  No. REV.DRN: P  Hogan RGCarrum  Downs.Victoria. Australia.  3201A2A3A3B2C1D1B1See  Bugzilla  Bug  #  Upissued  to  A2  and  frozenUpissued  to  A3See  Bugzilla  Bug  #  2696,  2748,2757,  2770,2819,    2872,    2876,  2877Up  issued  to  B1  and  frozen.Bugs  2990,  2993,  3001:  R80-83,86-89=100R.  NF  parts  fixed.  Q6=NF.PCB  Rev  C  and  schematic  update.  See  ECN.N/AN/AN/AN/AN/AG.  RankinG.  RankinG.  RankinG.  RankinBWABWAPAH21/02/0722/03/0722/03/0722/03/0723/05/0730/05/0719/06/07PCB  Rev  D  Schematic  update  see  ECN  sheet195-01-100 DSTATUS  LEDS+3v3_LED+3v3_LED+3v3_LED"Tx"  =  red,  "Pwr"  =  green  (default  condition)"RxSIG"  =  red,  "Sync"  =  greenFROM  RADIO  MODULE+3v3_LED+3v3_LED2007"TxD"  =  red,  "RxD"  =  green,  BOTH  "TX  &  RX"  =  amber"TxD"  =  red,  "RxD"  =  green,  BOTH  "TX  &  RX"  =  amberMODULE-DC-POW-LEDMODULE-Rx-SYNC-LEDMODULE-Tx-LEDPORTB-TXD-LEDPORTA-TXD-LEDPORTA-RXD-LEDMODULE-RX-SIG-LEDPORTB-RXD-LEDR80390RR8151RR82390RR8351RR86390RR8751RR88390RR8951RR841K+5V23412H1KPBL-3025SURKMGKC3412H2KPBL-3025SURKMGKC3412H3NF  (KPBL-3025SURKMGKC)3412H4KPBL-3025SURKMGKC3412H5KPBL-3025SURKMGKCVIN3GND1VOUT 2VOUT 4
  Page 27© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualOverlay
  Page 28© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualParameter900MHz Specifi cation2.4GHz Specifi cationFrequency RangeFCC: 902 – 928MHz, ACMA: 915-928MHz2.4 - 2.4835MHzAntenna Impedance:50Ω50ΩMain Antenna Connector Type:MMCXMMCXAuxiliary Antenna Connector Type:MMCXMMCXFrequency Error (over temp range):+/- 1.5ppm+/- 3.0ppmSupply RailsDC Supply #15.0V ±5%5.0V ±5%DC Supply #23.3V ±5%3.3V ±5%Current Consumption (nom @ +25° C)      +10dBm output power      130mA@5v240mA@3v3 & 117mA@5v      +20dBm output power240mA@5v360mA@3v3 & 275mA@5v +27dBm output power530mA@3v3 & 440mA@5v      +30dBm output power820mA@5vRX<1mA @ 5.0V270mA @3.3V <1mA @ 5.0V270mA @3.3V Current Consumption (maximum)+5.0v 1.35A760mA+3.3v 375mA540mAI/O ConnectorOupiin 2216-40-G-10-DPUOupiin 2216-40-G-10-DPUOperating Temperature-40 to +75°CDuty cycle limits apply.-40 to +75°CDuty cycle limits apply.Humidity5 – 95% non-condensing5 – 95% non-condensingStorage Temperature-40°C to +85°C-40°C to +85°CDimensions80mm x 55mm x 8mm (includ-ing connectors)80mm x 55mm x 8mm (includ-ing connectors)Modulation technique2 Level GFSK 2 Level GFSK Bandwidth382kHz382kHzPart I – Specifi cations
  Page 29© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualPart Number  DescriptionYagi AntennasBMY890K 10dBd, 900MHz Yagi Directional Antenna Bluewave, Marathon SeriesBMY890G 6.5dBd, 900 MHz Yagi Directional Antenna Bluewave, Marathon SeriesBGY890K 10dBd, 900 MHz Yagi Directional Antenna Bluewave, Gaurdian SeriesBGY890G 6.5dBd, 900MHz Yagi Directional Antenna Bluewave, Gaurdian SeriesBXY24XI 6dBd, 2,4GHz Yagi Directional Antenna Bluewave, Sentinel SeriesBXY24XK 8dBd, 2,4GHz Yagi Directional Antenna Bluewave, Sentinel SeriesBXY24XM 10dBd, 2,4GHz Yagi Directional Antenna Bluewave, Sentinel SeriesOmni AntennasBMO902J 9dBd, 900MHz Omni Directional Antenna Bluewave, Marathon SeriesBMO902H 7dBd, 900 MHz Omni Directional Antenna Bluewave, Marathon SeriesBMO902G 6dBd, 900 MHz Omni Directional Antenna Bluewave, Marathon SeriesBGO902G 6dBd, 900MHz Omni Directional Antenna Bluewave, Gaurdian SeriesBXO24XD 1dBd, 2.4GHz Omni Directional Antenna Bluewave, Sentinel SeriesBXO24XG 4dBd, 2.4GHz Omni Directional Antenna Bluewave, Sentinel SeriesBXO24XJ 7dBd, 2.4GHz Omni Directional Antenna Bluewave, Sentinel SeriesBXO24XM 10dBd, 2.4GHz Omni Directional Antenna Bluewave, Sentinel SeriesANT2G4WHIP 0dBd, 2.4GHz Omni Directional Antenna Trio Datacom, Whip SeriesPanel AntennasBXL24XM 10dBd, 2.4GHz Panel Directional Antenna Bluewave, Sentinel Series          WARNINGChanges or modifi cations not expressly approved by Trio Datacom  could void the user’s authority to operate the equipment. Fixed antennas require installation preventing end-users from replacing them with non-approved antennas. Antennas not listed in the above table must be tested to comply with FCC Section 15.203 (unique antenna connectors) and Section 15.247 (emissions). Please contact Trio Datacom Inc. if you need more information.Appendix – FCC Approved Antennas
  Page 30© Copyright 2008 Trio DataCom Pty. Ltd. O Series Data Radio – User ManualInnovative and sophisticateddigital communicationsdesigns products and solutionsInformation subject  to change without notice.© Copyright 2008 Trio DataCom Pty Ltd. All rights reserved. Issue: 08-08HEAD OFFICE41 Aster Avenue,Victoria, Australia 3201Phone +61 3 8773 0100 Fax +61 3 9775 0505 sales@triodatacom.comwww.triodatacom.comNORTH AMERICA48 Steacie Drive,  Kanata, ON Canada K2K 2A9Tel: (613) 287 0786      Fax: (613) 591 1022Toll Free: (866) 844 8746 (TRIO)sales-na@triodatacom.comwww.triodatacom.com