Form 57033 Rev. A 01-05-2004VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUAL5500 MORTISE  LOCKAUTOBOLT5500 MORTISE  LOCKSTANDARDThe VIP 5500 series lock is a microprocessor controlled, electromechanical locking system.It is an open architecture product designed to interface with 3rd party panels encompassingall the features of the lock, reader, door status and egress (rex/request to exit) indication inone fire-rated piece of hardware. The 5100 employs a heavy-duty mechanical design testedand complying with ANSI/BHMA grade 1 standards for performance and reliability. It is pow-ered by 12 or 24 volts DC with only four wires required - two for power and two for commu-nications. The lock communicates with a PIB (panel interface board) which communicateswith the panel as if it were separate components of an access control system.Operationally, the outside lever is normally locked and the inside lever always retracts thebolt to allow egress. Electronic access control is achieved by entering an”Access Credential”(magnetic stripe card or Prox fob or card). The panel controls the lock through the PIB.Please refer to all instruction manuals involved in the installation before you begin. Functions:VIP 5594-FSA: (1” AutoBolt) - Fail Safe (unlocked)VIP 5594-FSE: (1” AutoBolt) - Fail Secure (locked)VIP 5596-FSA: (3/4” latch) - Fail Safe (unlocked)VIP 5596-FSE: (3/4” latch) - Fail Secure (locked)Models:MG: Magnetic stripe card readerPX: HID Prox card readerStandard Monitoring Switches:DSM: Provides door status via data link to panel interfaceKSM: Provides mechanical key use events via data link to panel interfaceREX: Provides indication of inside lever use for request to exit input via data link to panel interfaceOptions:T3: Track 3 card reader (data must be ABA track 2 format) - MG onlyEXT: exterior use option - MG only (PX model has this standard)KD: Keyed Different, includes Schlage Everest cylinderKA: Keyed Alike, includes Schlage Everest cylinderLC: Less CylinderSLB: 2-3/4” backset, 1/2”  latch boltOLB: 2-3/8” backset, 1/2” latch boltELB: 2-3/4” backset, 3/4” latch boltBEFORE YOU BEGIN:Standard units are shipped from the factory to fit 1-3/4” doors. Verify the door thickness. If the door is not 1-3/4” thick, verifythat the door thickness option was ordered or consult factory.PRE-INSTALLATION CHECK:AN OPEN ARCHITECTURE SYSTEM REQUIRES AT LEAST THREE COMPONENTS - A PANEL INTERFACE BOARD (PIB), ANACCESS CONTROL PANEL (BY OTHERS) TO WHICH THE PIB IS CONNECTED AND THE VIP LOCK. SEE DOCUMENTATION FORTHE ACCESS CONTROL PANEL/SOFTWARE THIS LOCK WILL BE USED WITH FOR ANY PRE-INSTALLATION TESTINGREQUIREMENTS AND REMEDIES. REFER TO THE WIRING INFORMATION INCLUDED WITH THE PIB FOR MORE INFORMATION.PIBPX MGDoor Thickness Kits:Available in 1/8” increments from 1-3/8” to 2-1/2”This device complies with part 15 of the FCC rules. Operation is sub-ject to the following two conditions: (1) this device may not causeharmful interference, and (2) this device must accept any interferencereceived, including any interference that may cause undesired opera-tion. Changes or modifications not expressly approved by the partyresponsible for compliance could void the user’s authority to operatethe equipment.
Form 57033 Rev. A 01-05-20042VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUAL1. PREP DOOR AND FRAME (IF NOT ALREADY DONE):A. Determine door hand. B. Mark the horizontal and vertical centerlines for the lock case (on door edge), strike, lever, and inside escutcheon. Notethat the backset is actually 2.813” (or 2 13/16”). This is very important for proper mounting.C. Place template on inside of door (opposite the side that the keypad/reader will be on). Line up the correct reference lineson the template with the edge of the door, depending on the hand (see paper template). The centerline on the door shouldline up with the vertical centerline of the template. Use the paper template to mark all holes. (Though the paper template isthe preferred way to prep the door, the dimensions below may be used if a paper template is not available.)D. Drill required holes. Note that all holes are required except the 3/4” hole just below the 1” hole, this is only required if thelock has the DSM (door status) switch.FOR DOOR SWITCHWIRES:3/4” HOLE 1” DEEPDO NOT DRILL THRUDOOR!
Form 57033 Rev. A 01-05-20043VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUALSuggested wire raceway:1/2” hole into top of mortise pocket.Wiring will exit toward insidethrough this hole.FSE & FSA HARD WIRED MODELS REQUIRE WIRING TO BE RUNTO THE MORTISE POCKET FROM THE HINGE SIDE. BELOW IS ASUGGESTED WAY TO DO THIS. A DOOR CORD OR ELECTRICHINGE OR TRANSFER DEVICE MUST BE USED TO GET WIRINGFROM THE FRAME TO THE DOOR. NOTE THAT WHEN USING ANELECTRIC HINGE IT IS RECOMMENDED THAT THE POWERWIRES BE DOUBLED OR TRIPLED UP (ON BOTH THE POSITIVEAND GROUND LEGS) TO AVOID SIGNIFICANT VOLTAGE DROPTHROUGH THE THIN WIRES IN THE HINGE.
Form 57033 Rev. A 01-05-20044VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUAL2. INSTALL CYLINDER, GASKET AND STANDOFFS:A. Install cam onto cylinder. Cam can be either a cloverleaf (not shown) or straight, 11/16” design (shown).B. Insert standard, 1-1/8” mortise cylinder into outside escutcheon from front (keypad/reader) side with keyway down.C. Slide lock washer into place with tab on top facing out, as shown below.D. Using nut tool (provided) tighten nut onto cylinder.E. Line up nearest notch on nut with tab on lock washer and bend tab into notch using nut tool so nut is secure. F. Install exterior gasket (if used).G. Install upper and lower standoffs.CYLINDER RECOMMENDED CAM:SCHLAGE EVEREST: P/N B502-948SCHLAGE CLASSIC: P/N B502-191NUT TOOLEXTERIOR GASKETLOCK WASHERNUTSTANDOFFS - UPPERSTANDOFFS - LOWERTABNOTE:BLOCKING RING REQUIRED FOR CYLINDERLENGTH GREATER THAN 1-1/8”.THICKNESS = CYLINDER LENGTH -1 1/8”
Form 57033 Rev. A 01-05-20045VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUAL3. CHANGE HAND (IF NECESSARY):NOTE: The locks are shipped as ordered from factory. Followthe steps below to reverse handing:TO CHANGE HAND OF LOCK CASE:A. With bolt fully extended, insert change pin (included in thehardware pack) into hole. (It will snap over a groove on themain shaft, holding it in place.)B. Remove set screw in bolt so bolt can be removed.C. Rotate bolt and reinstall on to shaft. Do not remove spring.D. Apply thread locking compound to set screw. (Loctite 242 recommended)E. Install and tighten set screw (from other side, as shown).F. Remove change pin.5/32” SOCKET CAP SCREWLOCTITE 242 RECOMMENDEDOUTSIDE ESCUTCHEONOUTSIDE HANDLECHANGE PINLOCK CASE5/64” HEXWRENCHBOLT(AUTOBOLT SHOWN)TO CHANGE HAND OF LEVERS:A. Loosen 5/32” socket cap screw and remove lever.B. Rotate handle to opposite position.C. Apply thread locker to screw. (Loctite 242 recommended)D. Reinstall handle.E. Repeat for inside escutcheon (not shown).ABCEDF
Form 57033 Rev. A 01-05-20046VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUALLOCK CASE#12 COMBINATIONSCREWSFOR PROPER MONITORING OF DOORSTATUS, FEED WIRE THROUGH WIREHOLE TOWARD INSIDE OF DOOR ASSHOWN.4. INSTALL STRIKE BOX AND STRIKE:5. INSTALL LOCK CASE:Install lock case into edge of door. If the lock has the DSM switch, feed the wire harness though the 3/4” hole as shownbelow. Secure to door with #12-24 combination screws.IMPORTANT!Strike included with lock MUST beused for proper operation of mortiselockset.
Form 57033 Rev. A 01-05-20047VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUAL7. INSTALL OUTSIDE SPINDLE, OUTSIDE ESCUTCHEON AND BASE PLATE ASSEMBLY:Install outside escutcheon and spindle then install base plate assembly onto inside of door. Use socket cap screws withwashers on top standoffs and phillips head screws on lower standoffs.  Note that the cam on the outside escutcheon mustbe positioned with the dot at the 6 o’Clock position and outside spindle must be inserted as shown in details.NOTE: Battery Powered inside baseplate shown.OUTSIDE SPINDLE MUST BEINSERTED AS SHOWNSOCKET CAPSCREW, WASHERS5/32” HEXWRENCHBASE PLATE ASSEMBLYPASS WIRING HARNESS THROUGH 1”HOLE IN DOORPHILLIPS HEADSCREWSDOT - FACESDOWNOUTSIDESPINDLEPOSITIONCAMDETAILIMPORTANT!DO NOT OVERTIGHTENFASTENERS OR DOORWILL COMPRESS.
Form 57033 Rev. A 01-05-20048VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUALFIELD WIRING FROMPANEL AND POWERSUPPLY.DOOR SWITCHREX INPUT(PLUG IN WHEN INSIDEESCUTCHEON ISINSTALLED)8. MAKE WIRING HARNESS CONNECTIONS :A. Plug MAIN WIRING HARNESS into PC board.B. Plug MAKE FIELD CONNECTIONS TO TERMINAL BLOCK.C. Pug in DOOR STATUS SWITCH as shown.D. Verify correct lock type setting (FSE/FSA) - see dip switch setting. Note: as ordered from the factory.E. If lock is the one farthest away from PIB set termination resistor to “on”. All others should be in the “off/parked” position.F. Test operation of inside lever to make sure that latch retracts fully.IMPORTANT! See PIB manual for additional connecting instructions.SHIELDDATA ADATA BGROUNDV+ 1.0A @ 12VDC0.5A @ 24VDCOUTSIDEMAIN HARNESSCONNECTION OFF(PARKED)ONTERMINATIONRESISTOR:1: LOCK ADDRESS (SEE CHART)2: LOCK ADDRESS (SEE CHART)3: ALWAYS SET TO OFF4: ALWAYS SET TO OFF5: OFF = FAIL SECURE (FSE)ON = FAIL SAFE (FSA)6: OFF = ALL MG LOCKSON = ALL PX LOCKS7: ALWAYS SET TO OFF8: ALWAYS SET TO OFF9: ALWAYS SET TO OFF10: ALWAYS SET TO OFFLOCKADDRESS1LOCKADDRESS2 LOCKADDRESS3 LOCKADDRESS4 DIP SWITCH1OFF ON OFF ONDIP SWITCH2 OFF OFF ON ONDIPSWITCHNUMBER:Note:Lock addresses must be used in sequence and cannotbe the same for any two locks connected to a PIB. Forexample, if the system has three locks, use addresses1, 2, and 3 (but not 4). Lock address will correspond topanel address on the PIB.
Form 57033 Rev. A 01-05-20049VIP 5500 OPEN ARCHITECTURE MORTISE LOCKINSTALLATION MANUALASSEMBLE SPRING ONTOINSIDE SPINDLE AND INSERTINTO CAM IN LOCKSET ASSHOWNINSTALL ARMORFRONT. SHIM LOCKCASE IF NECESSARYTO CENTER IT IN THEPOCKET.INSIDE ESCUTCHEONPHILLIPS SCREWS(STANDARD) ORNO.8 SPANNERSCREWS(HSS OPTION - NOTSHOWN)9. INSTALL INSIDE SPINDLE, BATTERIES, AND INSIDE ESCUTCHEON:A. Assemble spring onto inside spindle as shown. install spindle into cam in lockset. Note that the flat side faces away fromthe door (See detail).B. Install inside escutcheon, making sure that the inside spindle engages the lever cam. While installing, plug in REX switchconnector.C. Test operation of inside lever to make sure that latch retracts fully.D. Install armor front. (Center lock case using shims if necessary.)DETAILPLUG IN REX SWITCH WHENINSTALLING INSIDEESCUTCHEON ASSEMBLY