Scanreco G5CUM 2.4 GHz Transceiver User Manual

Scanreco AB 2.4 GHz Transceiver

User Manual

Instruction Manual66064 AEnglishDocument Revision LanguageG5 CU M
Attribute InformationDocument Type Instruction ManualTitle SCANRECO G5 CU MDocument No. 66064Language EnglishRelease date 2013-05-20Original EnglishRelease date (original) 2013-05-20Author SCANRECOCompany SCANRECO AB, SWEDENRevision Date NoteA 2013-05-20 First releaseDocument informationRevision historyAll rights reservedDesign, equipment, technical data and specications are subject to change or improvement without prior notice. The text in this instruction manual, or any part of it may not be reproduced or transmitted in any form or by any means, including electronic, mechanical, photocopying, recording, storage in an information retrieval system, or otherwise, without prior written permis-sion of SCANRECO AB, SWEDEN.Document type Document number PageRevInstruction Manual 66064 A2 of 9
         G5 receiver                          Product description      The Central Unit (CU) is manufactured in robust plastic housing and provides contacts for the connection of power supply and electro-hydraulic valves. Several of the outputs can also be used as digital inputs. Depending on the version of the G5 Central unit, it can either be equipped with MOSFET outputs and Deutsch connectors or can have relay outputs with terminal block.Since the central unit can be exposed to very tough environments, the box is encapsulated to give protection from damp, heat, cold, dust, vibration and corrosive environments.The Central unit has short circuit protected inputs and outputs and has protection against reverse polarity, over-voltage, large incoming voltage transients and EMC/RF.LabelDocument type Document number PageRevInstruction Manual 66064 A3 of 9
                   MOSFET Digital Output                 The MOSFET digital outputs are designed to control electro-hydraulic valves but can also be used to load other accessories such as lamps or motors.                    Digital inputs                    Estop    The digital inputs can be used as a switch to control different functions on the central unit or on the HCU. The maximum input voltage shall not exceed the supply voltage. The Estop function works as a safety function.The output is active each time the HCU is active and communication has been established withthe Central unit. This output is normally connected to a dump valve. It is required for the systeminstaller to use this or similar function for the operator safety.The Estop digital output shares the same properties as the other digital outputs.Exspansion boardsDescription of expansion functions Number of exspansion functionAnalof inputs 1-10Analog outputs 1-5Digital I/O 1-20PWM 1-5The main board may be used stand alone or together with one expansion board.There are several different expansion boards.All expansions boards have the same mechanical outline. They may have different funcionalities depending on customers application.The differnt functions are exemplied in the table below:Document type Document number PageRevInstruction Manual 66064 A4 of 9
Main board         Main board with expansion board   (49837)              Terminal schematics G5-CU M19                Terminal schematics G5-CU M21      1122113104958677685941031121211122113104958677685941031121211 = Output/input 162 = Output/input 153 = GND4 = Output/input 145 = Estop6 = Power Supply +7 = Output 18 = Output 29 = Output 310 = Output 511 = Output 412 = Output/input 61 = Output/input 162 = Output/input 153 = GND4 = Output/input 145 = Estop6 = Power Supply +7 = Output 18 = Output 29 = Output 310 = Output 511 = Output 412 = Output/input 61 = Output/input 72 = Output/input 83 = Output/input 94 = Output/input 105 = Output/input 116 = Output/input 127 = RS232 TX8 = RS232 RX9 = Output/input 1310 = Output/input 1711 = Output/input 1812 = Output/input 191 = Output/input 72 = Output/input 83 = Output/input 94 = Output/input 105 = Output/input 116 = Output/input 127 = Mosfet output or 4 - 20 mA input8 = Mosfet output or 4 - 20 mA input9 = Output/input 1310 = Output/input 1711 = Output/input 1812 = Output/input 19Document type Document number PageRevInstruction Manual 66064 A5 of 9
127mm 57mm186mm117mmSize: approx. ~ 127 x 117 x 57 mm / ~ 5,0 x 4,6 x 2,2 in.          Technical Data Central Unit                 Attribute InformationHousing material Plastic PCIP-class IP67 (for versions with cable glands IP65)Ambient temperature -25˚C to +70˚CSupply voltage 9-36VDCFuse Not required.Current consumption at idle <30mAMOSFET Output load 3 A, Max simultaneously load for each CU is 10A.Relay Output load Max 10 AHousing screw torque 0,8 NmWeight Approx. 0,5KgDocument type Document number PageRevInstruction Manual 66064 A6 of 9
Attribute InformationFrequency 2,400  - 2,4835 GHzChannels managementFHSSDSSSTHSSChannel order PseudorandomChannel capacityDuplexSystem address/ID<16777216 unique system addresses availableRedundancy CRC-16Range 100 meters                Technical information              The G5 system family incorporates an automated frequency jumping technology, a reliable radio transmission highly resistant to interference.The radio transmission takes place within the ISM-band used at pre-dened channels.The channel switching takes place multiple times per second following a pseudorandom se-quence. This ensures that transmission takes place on an optimal frequency at all times!No transmitter uses the same pseudorandom sequence order when switching channels; this minimizes the risk of two G5 systems interfering with each other.The G5 Pocket is approved to transmit on the ISM band. The radio is license free for the end user.        Radio informationDocument type Document number PageRevInstruction Manual 66064 A7 of 9
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.CAN ICES-3 (A)/NMB-3(A)The antenna(s) used for this transmitter must be installed to provide a separationdistance of at least 20 cm from all persons and must not be co-located or operatingin conjunction with any other antenna or transmitter.L’antenne (s) utiliseé pour cet émetteur doit être installé pour fournir une distance de séparation d’au moins 20 cm de toute personne et ne doit pas être co-localisées ou opérant en conjonction avec une autre antenne ou émetteur.Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Warning                FCC information                             Industry Canada Information            Document type Document number PageRevInstruction Manual 66064 A8 of 9
Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.