 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-67 2600-00F1W8GAA 4.0  Figure 3.48  CPRI Cable Pin Map (Stacking, Case #3) L0 L9CA #1 L9CA #0 L2 L4 Optic0 (LTE0) Optic1 (LTE1) Optic2 (LTE2) Optic3 (LTE3) L1 L3 L5 [UADU] [RRH-B4 #0] L0 L2 L4 L1 L3 L5 [U-RAS Flexible V2 DU] L0 L0 L0 MRA-F #5 MRA-F #4 MRA-F #3 MRA-F #2 MRA-F #1 MRA-F #0 L1 L1 L1 L1 L1 L1 L0 L0 L0 Optic0 (LTE0) Optic1 (LTE1) Optic2 (LTE2) Optic3 (LTE3) [RRH-B4 #1] Optic0 (LTE0) Optic1 (LTE1) Optic2 (LTE2) Optic3 (LTE3) [RRH-B4 #2] Optic4 (WiMAX0) Optic6 (WiMAX2) Optic5 (WiMAX1) Optic7 (WiMAX3) Optic4 (WiMAX0) Optic6 (WiMAX2) Optic5 (WiMAX1) Optic7 (WiMAX3) Optic4 (WiMAX0) Optic6 (WiMAX2) Optic5 (WiMAX1) Optic7 (WiMAX3)
 Ver.  CHAPTER 3. Connecting Cables 3-68 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure 3.49  CPRI Cable Connection_Stacking, Case #3 (1) [UADU Front] [UADU Front] [U-RAS Flexible V2 DU Front]   1)    Install CPRI cables (RRH-B4 interface) between: - RRH-B4 and L0, L2, and L4 ports on UADU L9CA #0 and #1 - RRH-B4 and L0 port on U-RAS Flexible V2 DU MRA-F #0-#5 2)    Connect the UADU- and U-RAS Flexible V2 DU-side connectors to the following ports. - L0, L2, and L4 ports on UADU L9CA #0 and #1 - L0 ports on U-RAS Flexible V2 DU MRA-F #0-#5 [UADU Front] [U-RAS Flexible V2 DU Front]   [UADU Front] [RRH-B4 #0] ‘A’ CPRI Cable CPRI Cable ‘B’ [RRH-B4 #1] ‘A’ CPRI Cable CPRI Cable ‘B’ [RRH-B4 #2] ‘A’ CPRI Cable
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-69 2600-00F1W8GAA 4.0  Figure 3.50  CPRI Cable Connection_Stacking, Case# 3 (2) CPRI Cable (RRH-B4 Interface) CPRI Cable Connector (LC/PC) Optic0 (LTE0) Optic1 (LTE1) CPRI Cable (RRH-B4 Interface) CPRI Cable Connector (LC/PC) Optic0 (LTE0) Optic1 (LTE1) Detail ‘A’ CPRI Cable (RRH-B4 Interface) CPRI Cable Connector (LC/PC) Detail ‘B’ Detail ‘C’ Optic0 (LTE0) Optic1 (LTE1) Optic4 (WiMAX0) Optic6 (WiMAX2) Optic5 (WiMAX1) Optic7 (WiMAX3) Optic6 (WiMAX2) Optic7 (WiMAX3)
 Ver.  CHAPTER 3. Connecting Cables 3-70 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 3.5.2  RET Cable Connection Follow the steps below to connect the Remote Electrical Tilting (RET) cable to control the antenna tilting angle remotely.  Table 3.15  RET Cable Connection Classification Description Installation Section RF Antenna~RRH-B4 Cable RET Cable Ass’y Connector RS-485  Figure 3.51   RET Cable Connection (1)  RET Cable Ass’y 1)    Install a RET cable ass’y from the RF antenna to the RET port of RRH-B4 [RF Antenna]
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-71 2600-00F1W8GAA 4.0  Figure 3.52   RET Cable Connection (2)  RET Connector (SAMWOO, SU-20SP-8P) RET Cable (Shield Cable) Heat Shrink Tube (Jelly Type) Heat Shrink Tube (Jelly Type) Heat Shrink Tube (Jelly Type) 2)    Connect the RET cable connector to the RET port at the bottom of the RRH-B4
 Ver.  CHAPTER 3. Connecting Cables 3-72 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure 3.53  RET Cable Connector  Table 3.16  RET Cable Connector Pin Map RET Connector Samwoo, SU-20SP-8P Pin Function 3 RS485B 4 DGND 5 RS485A 6 +21 V 7 +21 V RTN 1, 2, 8 NC   RET   - When 21 VDC volts are applied, the current supplied to the RET from RRH-B4 must be 1 A or lower.     - The exterior of the RET connector must be made of metal without vent hole or other UL certified material.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-73 2600-00F1W8GAA 4.0 3.5.3  RF Cable Connection Follow the steps below to connect the RF cable.  Table 3.17  RF Cable Connection Classification Description Installation Section RRH-B4~RF Antenna Cable RRH-B4~RF Antenna 1/2 in. Feeder Line Connector RRH-B4 Mini Din Type-Male RF Antenna Din Type-Male Recommended Torque Value Mini Din Type-Male 1.45 lbf.ft (20 kgf.cm) Din Type-Male 14.50 lbf.ft (200 kgf.cm) Working Tools Cable Cutter, Wire Stripper, Nipper, Torque Wrench, Spanner, Knife, Soldering Iron, Lead    Installing the Antenna  When you install the antenna, the antenna must be within the protective angle (left/right side 45° each from the central axis) to prevent the antenna from lightning damage.                  Lightning Rod 45° 45° RF Antenna
 Ver.  CHAPTER 3. Connecting Cables 3-74 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 RF Cable Configuration The RF cable is connected in the following two methods. Prepare and install parts based on the method agreed by a service provider or the site conditions.  Table 3.18    RF Cable Connection at Antenna Connection Area Case Description Case #1             Connect a 7/8 in. or longer feeder line directly to the RF antenna. - If a space for min. radius of curvature can be secured when a 7/8 in. or longer feeder line is used. - If no excessive force is applied to the connector assembled to the antenna port or cable because the straight cable section is long enough. Case #2             Connect a 1/2 in. feeder line (jumper cable) to the RF antenna. - If a space for min. radius of curvature cannot be secured when a 7/8 in. or longer feeder line is used. - If excessive force is applied to the connector assembled to the antenna port or cable and it may cause poor contact or damage because the straight cable section is not long enough. ※  7/8 in. or longer feeder line: 7/8 in./1 1/4 in./1 5/8 in. feeder line, etc. ※  The RF cable must be connected based on the method agreed by a provider or the site conditions.   R’ RF Antenna Straight cable section Min. radius   of curvature Straight cable section Min. radius   of curvature R’ RF Antenna
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-75 2600-00F1W8GAA 4.0  Figure 3.54   RF Cable Configuration   RF Antenna Connector   As different connector types may be used depending on the RF antenna type, check the antenna connector before connecting the cable.  RF Cable Identification Tag Installation Attach the identification tape in the below table to the RF cable.    Table 3.19  RF Cable Identification Tag Category Description Installation position Attach the identification tag to the both ends of the antenna.   Materials Use the material of aluminum coated by vinyl for the identification tag. Fixing  method - Antenna side: Attach the tag to the feeder line using binding strings through the two holes on the tag. - Equipment Side: Cover up the feeder line with the tag and fix it using binding strings through the two holes on the tag. Identification method The markings must be prevented from being erased by using relief engraving or coated labels. RF Antenna [RRH-B4] 1/2 in. Feeder Line (RRH-B4~RF Antenna)
 Ver.  CHAPTER 3. Connecting Cables 3-76 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 RF Cable Connection Follow the steps below to connect the cable between RRH-B4 and RF antenna.  Figure 3.55   RF Cable Connection (1)  Mini Din Type-Male Connector 1/2 in. Feeder Line (RRH-B4 RF Port~RF Antenna)  1)    Before connecting the connector to the RF port (Mini Din type-female) at the bottom of RRH-B4, insert a heat shrink tube (jelly type).  2)    After connecting the connector, place the heat shrink tube inserted in the previous step at the connecting area and shrink it using a heating gun. Mini Din Type-Female Connector Heat Shrink Tube (Jelly Type)
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  3-77 2600-00F1W8GAA 4.0  Figure 3.56  RF Cable Connection (2)  3)    Insert a heat shrink tube (jelly type) for finishing at the end of the antenna jumper cable (1/2 in. feeder line) with a Din type-male connector installed and then connect to the antenna input port.  4)    When the connector is connected completely, insert the heat shrink tube inserted in the previous step up to the connecting area and shrink it using a heating gun.    Antenna Connector (Din Type-Female) 1/2 in. Feeder Line Heat Shrink Tube (Jelly Type) RF Antenna Din Type-Male Connector for 1/2 in. Feeder Line
 Ver.  CHAPTER 3. Connecting Cables 3-78 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Checking RF Cable Connection After connecting the RF cables, perform the continuity test and feeder cable return loss to check if the RF cable is changed and measure VSWR of antenna and RF cable.     Measure all cables of section  ~ . The measured VSWR should be the specification value or less. If the VSWR exceeds the specification value, disassemble the connector and measure each section separately.     Checking VSWR for Minimum Cable Bend Radius and Length of RF Cable   If the VSWR value for minimum cable bend radius and length of RF cable is not applied, system may not work properly because RF signals cannot transmit or receive smoothly. So, the VSWR value for minimum cable bend radius and length of RF cable must be checked and applied.   Cautions When Measuring VSWR   When measuring VSWR, if you open the antenna port when the transmission output is not completely off, a spike signal may flow into the reception path, which may cause damage to LNA. Make sure the transmission output is completely off when measuring VSWR.     Checking the Specifications of Antenna/Arrestor Connector  Depending on the supplier or manufacturer of antenna/arrestor the connector type may be different. Also, the detail specifications of a connector may be different depending on cable type even for the same connector type. Therefore, check the detail specifications of a connector before preparing parts.   Ex)    Din Type-Male: for 1/2 in. Feeder line, for 7/8 in. Feeder Line   Connection Part of System External Interface Connector   Antenna
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  4-1 2600-00F1W8GAA 4.0 CHAPTER 4.  Checking Installation Status      4.1  Installation Checking Procedure Below is the procedure to check installation status.  Figure 4.1   Installation Checking Procedure  Nok OK Sharing Inspection Results Taking Corrective Actions Checking the Results of Corrective Actions On-site Inspection Inspection Checklist Inspection Checklist/Corrective Actions Sharing the Results of Corrective Actions and Preparing Preventive Plan Inspection Plan
 Ver.  CHAPTER 4. Checking Installation Status 4-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Inspection Plan Create an inspection sheet per system and select an inspector to set an inspection schedule per site.  On-site Inspection and Inspection Checklist The on-site inspection is to perform inspection visually or using instruments for each specification, standard, and installation status, etc. based on the inspection checklist actually at a site where the system ins installed. The inspector must record the results onto the inspection checklist during or after filed inspection.  Sharing Inspection Results and Taking Corrective Actions The inspector must share the inspection results (inspection checklist/corrective actions) with a installation operator and the installation operator must take the corrective actions if necessary after reviewing the requirements.  Checking the Results of Corrective Actions The inspector must check if the corrective actions are properly taken. If they are not sufficient, the inspector must ask the installation operator to take the corrective actions again.  Sharing the Results of Corrective Actions and Preparing Preventive Plan After the corrective actions are all completed, the inspector must share the results with the installation operator and relevant departments and prepare a preventive plan to prevent the same or similar problems from re-occurring.  Table 4.1  Construction Situation Checklist Category Check Items Criteria Result Pass Fail Installing Equipment Appearance of equipment and mechanical parts Equipment damage such as Dent, scratch and crack, etc.   Placement of equipment and mechanical parts Maintenance and horizontal/vertical placement   Leveling condition of equipment and mechanical parts Horizontal/vertical fixing (level, weight, rubber hose, etc.)   Validity of status and specifications of tightening bolt/nut/washer, etc. Visual inspection and magnet check Compliance with tightening torque value   Board/blank panel installation status Checking assembly status   Insulation status Checking electrical contact between insulators (insulation resistance tester)   Other works (cable duct installation status, etc.) Checking position and installation status
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  4-3 2600-00F1W8GAA 4.0 Table 4.1  Construction Situation Checklist (Continued) Category Check Items Criteria Result Pass Fail Grounding Status of ground bar installation per usage Checking the separation of communication/power/lightning grounding   Cable Size Checking specifications such as thickness, etc.   Cabling and binding status Cable damage/properness installation route Checking binding interval and the condition of used materials   Cable connection Assembly and tightening condition of a pressure terminal Checking compliance with tightening torque value   Installation status of cable tag Checking position, marking, and tag installation type   Power Installation status of power supply and circuit breaker Power supply capacity/input voltage (tester) Checking circuit breaker type and capacity   Cable Size Checking thickness and length limitation   Cabling and binding status Cable damage/properness installation route Checking binding interval and the condition of used materials   Cable connection Cable damage/properness installation route Checking binding interval and the condition of used materials   Installation status of cable tag Checking position, marking, and tag installation type   Other data cables Cable size Checking cable specifications per usage   Cabling and binding status Checking cable damage/properness installation route, binding distance and condition of used materials   Cable connection Checking cable connection (Pin Map), assembly and tightening status of a connector and compliance with tightening torque value   Installation status of cable tag Checking position, marking, and tag installation type
 Ver.  CHAPTER 4. Checking Installation Status 4-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Table 4.1  Construction Situation Checklist (Continued) Category Check Items Criteria Result Pass Fail RF Antenna installation status Checking specifications, installation position, fixing status, and gap between antennas   Installation status of arrestor/line amplifier/splitter, etc. Checking specifications, installation position, and fixing status   Cabling and binding status Checking cable damage/properness of installation route/binding distance and the condition of used materials   Cable connection Checking cable connection status, connector assembly and tightening status, compliance with tightening torque value, and finishing   Installation of cable tag Checking position, marking, and tag installation type   Others Reserved ports and cable inlet status Finishing (dust cap, etc.)   Connection of equipment I/O port (Conduit/Cable Gland) Checking tightening status   Installation of cable installation route Installation of cable tray and duct, etc.   Status of inside/outside of the equipment and system surrounding area Checking the stocking condition of waste parts, waste materials, packing materials, etc.   Opinion
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  A-1 2600-00F1W8GAA 4.0 ANNEX A. Sector Antenna Installation      A.1 Cautions when Installing a Sector Antenna Precautions of antenna installation are as follows.  Sector antennas should be installed vertically. (±1°)  Antenna is the precise material, so be careful not to make damage or form change.  When moving antenna, use the tool suitable to rating. In addition, use the rated carrying device which is at least 200 % or more than antenna considering the stability.  Be careful not to give too much strength to the antenna.    If it rains, suspend connecting the feeder cable and antenna.    Fix it after adjusting the direction of antenna exactly.    Distance between steel tower and antenna and the distance between send-receive antennas are based on the antenna layout.  Attach the antenna on the position specified in the drawing.    Install the antenna not to make a feature change of the antenna considering the direction of the radiation.    Connect the antenna not making the alien substance flowed so that Passive Inter-Modulation Distortion (PMID) is not affected.  Measure VSWR of all antennas and the value should be within the regulated value.  A.2 Sector Antenna Layout The method of sector antenna layout is as follows.  1)    Use the transit to adjust the antenna installation direction exactly. 2)    Fix the direction of the sector antenna, same as the angle settled when designing the cell after installing the steel tower. 3)    Arrange the antennas of each sector to the sector directional angle at right angles by adjusting the distance between antenna and steel tower. In the event of the station whose the direction between sectors is not 120°, install it to make the steel tower and antenna direction different being careful of the tilt and azimuth. 4)    For circular platform, separate the antenna interval at maximum.
 Ver.  ANNEX A. Sector Antenna Installation A-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 A.3 Sector Antenna Installation The method of sector antenna installation is as follows.  1)    Put up an antenna pole and insert the sector antenna into the antenna pole using a fixing clamp. 2)    Set the antenna’s up/down tilt to 0° and fix the fixing clamps at the top and bottom. 3)    Adjust the tilted angle of the antenna by taking the signal strength into account.   The bolts on the upper and lower guide clamps must be loose as to allow angle adjustment of the antenna. 4)    After adjusting the antenna angle, tighten up the 4 loose bolts on the upper and lower guide clamps.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  A-3 2600-00F1W8GAA 4.0  Figure A.1   Sector Antenna Antenna Input Port Pole Main Radiation Direction Upper Fixing Clamp Lower Fixing Clamp Upper Guide Clamp Lower Guide Clamp Guide Clamp Bolt_2 Guide Clamp Bolt_1 Guide Clamp Bolt_3 Guide Clamp Bolt_4
 Ver.  ANNEX A. Sector Antenna Installation A-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0    Installing the Antenna   When you install the antenna, the antenna must be within the protective angle (left/right side 45° each from the central axis) to prevent the antenna from lightning damage.                        Lightning Rod 45° 45° Sector Antenna
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  B-1 2600-00F1W8GAA 4.0 ANNEX B. Installing Feeder Cable      B.1 Cautions When Installing Feeder Cable When installing the feeder cable (GPS/RF cable), the following cautions shall be considered:  Put a plate to work not to make damage for the surface of the feeder cable.   If there is external damage of the feeder cable, cut the damaged part and work wiring.    After connecting the antenna to the feeder cable, finish the connection part of the contracted pipe using the contracted tube.    Attach the cognitive tapes to the both ends of the feeder cable, which makes it easy to recognize.  When connecting cabinet, antenna and lightening arrestor, etc. to the feeder cable, connect strongly to prevent from generating reflected wave.  The curvature radius should be maximized, keep the minimum curvature radius.  Table B.1    Curvature Radius of Feeder Cable for Outdoor Specification Allowed Radius of Curvature Remark LS Feeder Line HFC-12D 1/2 in. 4.02 in. (125 mm) Outdoor HFC-22D 7/8 in. 9.84 in. (250 mm) HFC-33D 1-1/4 in. 14.96 in. (380 mm) HFC-42D 1-5/8 in. 20.08 in. (510 mm) RFS Feeder Line LCF12-50 1/2 in. 4.92 in. (125 mm) LCF78-50 7/8 in. 9.84 in. (250 mm) LCFS114-50 1-1/4 in. 14.96 in. (380 mm) LCF158-50 1-5/8 in. 19.69 in. (500 mm)           1/2 in. 7/8 in. 1-1/4 in. 1-5/8 in.
 Ver.  ANNEX B. Installing Feeder Cable B-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Table B.2    Curvature Radius of Feeder Cable for Indoor (Based on LS Feeder Line) Specification Allowed Radius of Curvature Remark LS Feeder Line HFSC 6D 1/4 in. 0.98 in. (25 mm) Indoor HFSC 10D 3/8 in. 0.98 in. (25 mm) HFSC 12D 1/2 in. 1.26 in. (32 mm) HFSC 22D 7/8 in. 4.92 in. (125 mm) RFS Feeder Line SCF14-50 1/4 in. 0.98 in. (25 mm) SCF38-50 3/8 in. 0.98 in. (25 mm) SCF12-50 1/2 in. 1.26 in. (32 mm) UCF78-50 7/8 in. 4.92 in. (125 mm)              Table B.3    Curvature Radius of LMR-400 (Based on Times Microwave System) Specification Allowed Radius of Curvature Remark LMR-400 1 in. (25.4 mm) Installation 4 in. (101.6 mm) Repeated           Radius of Curvature of Feeder Line   When installing a feeder line, the radius of curvature of the sections where cables bent should be larger than the allowed radius of curvature. If the radius of curvature for the feeder line installation is less than the allowed radius of curvature, it may affect the performance of the system.   1/4 in. 3/8 in. 1/2 in. 7/8 in.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  B-3 2600-00F1W8GAA 4.0  Ensure that the feeder cable does not interfere with steel towers, ladders and in the areas chiefly used by people.  Connect the connector to the antenna in a straight line and after connecting, do not apply excessive force.  Use the vinyl tape for electricity and heat shrink tube for the external exposed part of the connector not to avoid leak water.  Wind the self-bonding rubber tape overlapping (keep a distance as the half size of rubber tape) to the connector connection part and wind the vinyl tape for electricity to the 2 times or more and then cover with the jelly type heat shrink tube.    Connection of Feeder Cable Connector   Connecting the feeder cable connector is critical process, so the qualified workers who finished the related education should perform.  Table B.4   Connector Connection Torque Value Connector Torque Value SMA connector 0.18 lbf·ft (2.5 kgf·cm) TNC connector 0.65 lbf·ft (9 kgf·cm) N-type connector 1.45 lbf·ft (20 kgf·cm) Din-type connector 14.46 lbf·ft (200 kgf·cm)
 Ver.  ANNEX B. Installing Feeder Cable B-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 B.2 7/8 in. Feeder Line Ground Ground Kit Ground the 7/8 in. feeder line using the grounding kit located under the Tower Ground Bar (TGB) installed in the lower section of the tower or in the cable duct.  The procedure for connecting the ground kit to the 7/8 in. feeder line is as follows:  Figure B.1  7/8 in. Feeder Line Grounding (1)  2.17 in. (55 mm)  M6 Hex. Nut Ground Kit Insulation Tape Rubber Tape M6 × 25L Hex. Bolt M6 Spring Washer M6 Plane Washer M6 Plane Washer M6 Spring Washer 1)    Remove about 2.17 in. (55 mm) of the sheath of cable when the 7/8 in. feeder line is used.  2)    Open it by returning hook of the clamp fixing for Ground kit in the left direction. 1 2
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  B-5 2600-00F1W8GAA 4.0  Figure B.2    7/8 in. Feeder Line Grounding (2)  Protrusion area Clamp lock Ground Kit Clamp Scissors (knife) Rubber Tape Insulation Tape 3)    Insert the ground kit clamp into the place from which the 7/8 in. feeder line sheath is removed.    4)    Pull the clamp lock to the upward so that the lock can be hung on the global protrusion area on the side.    5)    Overlap the exposed part of the ground kit clamp using rubber tape (Keep a distance as the half size of rubber tape) and press it with your hands lightly to make rubber tape adhere well.    6)    Wrap the part where the rubber tape is attached using insulation tape two times or more. When cutting off the tape, cut it off neatly using a cutting device such as scissors or a knife. 6 7/8 in. Feeder Line 4 3 5
 Ver.  ANNEX B. Installing Feeder Cable B-6 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure B.3  7/8 in. Feeder Line Grounding (3)  7.87 in. (200 mm) Heating Gun Heat Shrink Tube   Heat Shrink Tube   7)    Align the heat shrink tube inserted when installing the 7/8 in. feeder line into the fixing part of the ground kit. - Heat shrink tube: jelly type, Φ 1.65 in., 7.87 in. (Φ 42 mm, 200 mm)  8)    Shrink the heat shrink tube by heating gun. 7 8
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  B-7 2600-00F1W8GAA 4.0  Figure B.4    7/8 in. Feeder Line Grounding (4)    Checking the Ground Kit and TGB Specifications   The specifications, clamp, and pressure terminal type of the ground kit and TGB differ depending on manufacturers. Make sure to check the specifications of the ground kit and TGB, and identify the installation method before installing it.  Table B.5  TGB Installation Example Category Description TGB Usage Earth terminal board for RF cable for grounding in using the feeder line of more than 7/8 in. TGB Location Lower section of cable rack in feeder cable duck - Less than 65.62 ft (20 m): 1 (Ex. steel tower lower section) - Exceed 65.62 ft (20 m): 2 or more (Ex. steel tower lower and upper section) Material Pure copper Installation Method Using the insulator to separate from the steel tower electrically Connection Method Extract the GV 35 mm2 ground cable to the direction of the floor and weld it to the tower’s ground cable.  9)    After the ground kit has been installed to the 7/8 in. feeder line, attach the pressure terminal (1 hole) of the ground cable connected to the ground kit to the TGB.  10) When attaching the pressure terminal, use M6 × 25L hex. Bolts. TGB (Tower Ground Bar) TGB Ground Cable (F-GV 35 mm2 × 1C) M6 × 25L Hex. Bolt (STS304) Pressure Terminal (1 Hole)  Ground kit 7/8 in. Feeder Line
 Ver.  ANNEX B. Installing Feeder Cable B-8 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 B.3 Tower Ground Construction 1)    Install a Tower Ground Bar (TGB) that will be used to ground a RF cable onto the tower. If the height of the tower is exceeds 65.62 ft (20 m), two or more TGBs should be installed (onto the lower and upper sections of the tower). If the tower is 65.62 ft (20 m) or less, one TGB should be installed. Since the TGB installation location and the number of TGBs to be installed can differ depending on the system environment and provider’s standards, consult your service provider. 2)    Each TGB should be grounded and separated from other grounds. If there is an existing ground bar or ground cable for TGB, install the TGB by branching from it using a ground cable (GV35 mm2 × 1C) ground cable. (However, the specification of TGB ground cable can be different, defending on the standard of service provider.) 3)    Tighten the Ground Kit (RF cable grounding assembly) to the TGB ground terminal and the tower hole using the pressure terminal hole attached at the end of the ground kit’s ground cable.  Figure B.5  Connecting the Tower Ground Cable Lightning Rod RF cable   (7/8 in. Feeder Line or more) Ground Kit TGB (Tower Ground Bar) [Tower Height>65.62 ft (20 m)] TGB Ground Cable (F-GV 35 mm2 × 1C)  Lightning Rod Ground Cable (GV 95 mm2 × 1C)  TGB (Tower Ground Bar) Ground Kit TGB Ground Cable (F-GV 35 mm2 × 1C)  TGB Ground Cable (F-GV 95 mm2 × 1C)
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-1 2600-00F1W8GAA 4.0 ANNEX C. Connector Assembly      C.1 RJ-45 (Shield Type) Procedure that assembles the RJ-45 (shield type) connector is as follows:  Figure C.1   Assembling the RJ-45 Connector (Shield Type) (1)  1), 2)    Prepare work tools and materials. 4)    Pass the cable through the   RJ-45 cap. 5)    Remove the coating 0.67 in. (17 mm) from the end. 6)    Push the shield backward,   and cut the aluminum shield. 7)    Cut the shield leaving a 0.2 in. (5 mm) of it. 8)    Arrange the cable in reference   to the pin map. 9)    Cut the cable to make it   0.47 in.(12 mm) long. 3)    Pass the cable through the   marking tube. 1 2 3 4 5 6 7 8 9
 Ver.  ANNEX C. Connector Assembly C-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure C.2    Assembling the RJ-45 Connector (Shield Type) (2)  10) Insert the RJ-45 modular jack. 11) Make sure that the shield does   not get in the RJ-45 modular jack. 12) Insert the cable completely into   the RJ-45 modular jack. 13) Compress the jack using the tool. 14) Compress the marking tube to finish the assembly. 10 11 12 13 14
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-3 2600-00F1W8GAA 4.0 C.2 RJ-45 (Normal Type) Procedure that assembles the RJ-45 (normal type) connector is as follows:  Figure C.3   Assembling the RJ-45 Connector (Normal Type)  1)    Prepare work tools and   materials. 2)    Insert the RJ-45 cap to the   cable. 3)    Remove the coating 0.67 in. (17 mm) from the end. 4)    Arrange the cable in reference   to the pin map. 5)    Cut the cable to make it   0.47 in. (12 mm) long. 1 2 3  4 5 6   7 8 7)    Compress the jack using the   tool. 6)    Insert the cable completely   into the RJ-45 modular jack. 8)    Push the RJ-45 cap to the   connector.
 Ver.  ANNEX C. Connector Assembly C-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 C.3 N type-male (LMR-400) Below is the procedure for assembling the N type-male cable connector to LMR-400 cable.  Figure C.4    N type-male Connector Assembling (1)  in.B in. 케이블 랙 1)    The components of the N type-male include   N type-male body, clamp ring, and heat shrink tube.  2)    Insert a heat shrink tube and clamp ring to the cable, and insert the cable into the ‘End1’ of the prep/strip tool. Then remove the shield and sheath except for the center conductor at the end of cable by rotating the tool clockwise.  3)    Insert the cable into the ‘End2’ of the prep/strip tool again, and remove the sheath except for the shield by rotating the tool.  4)    Trim the end of the center conductor by using a deburring tool. Heat Shrink Tube Clamp Ring N type-Male Body LMR-400 LMR-400 Prep/strip Tool End1 Prep/strip Tool End2 Deburring tool Center Conductor Shield Clamp Ring Heat Shrink Tube
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-5 2600-00F1W8GAA 4.0  Figure C.5    N type-male Connector Assembling (2)  in.B in. 케이블 랙 5)    Push a connector into the end of the cable. Then, push it further until the center conductor is firmly inserted into the pin connection part of the   N-Type male body. Make the shield overlap the N-Type male body, pull out the clamp ring, and let it go to its original position so that the remaining length may be folded. 6)    Cut off the folded length of the shield using a cutting device so that it does not protrude outside when the clamp ring is inserted.   After arranging the shield, push up the clamp ring toward the connector until the entire shield is covered. 7)    Using a compressor and hexagonal dies, pressurize the clamp ring to fix the cable and connector. 8)    Lift the heat shrink tube up to the connection point on the connector and shrink the heat shrink tube using a heating gun.
 Ver.  ANNEX C. Connector Assembly C-6 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 C.4 TNC-male (LMR-400) Below is the procedure for assembling the TNC-male cable connector to LMR-400 cable.  Figure C.6    TNC-male Connector Assembling (1) 1)    The components of the TNC-male include TNC-male body, clamp ring, and heat shrink tube.   2)    Insert a heat shrink tube and clamp ring to the cable, and insert the cable into the ‘End1’ of the prep/strip tool. Then remove the shield and sheath except for the center conductor at the end of cable by rotating the tool clockwise.   3)    Insert the cable into the ‘End2’ of the prep/strip tool again, and remove the sheath by rotating the tool. 4)    Trim the end of the center conductor by using a deburring tool. Heat Shrink Tube Clamp Ring TNC-Male Body Prep/strip tool End1 Prep/strip tool End2   Deburring tool   Clamp Ring Heat Shrink Tube LMR-400 Center Conductor LMR-400 Shield
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-7 2600-00F1W8GAA 4.0  Figure C.7    TNC-male Connector Assembling (2)  5)    Push a connector into the end of the cable. Then, push it further until the center conductor is firmly inserted into the pin connection part of the   N-Type male body. Make the shield overlap the N-Type male body, pull out the clamp ring, and let it go to its original position so that the remaining len1/2 in. be folded. 6)    Cut off the folded length of the shield using a cutting device so that it does not protrude outside when the clamp ring is inserted. After arranging the shield, push up the clamp ring toward the connector until the entire shield is covered. 7)    Using a compressor and hexagonal dies, pressurize the clamp ring to fix the cable and connector. 8)    Lift the heat shrink tube up to the connection point on the connector and shrink the heat shrink tube using a heating gun.
 Ver.  ANNEX C. Connector Assembly C-8 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 C.5 N type-male (1/2 in. feeder line) Below is the method for assembling the N type-male connector to the 1/2 in. feeder line.  Figure C.8  Assembling the N type-male (1/2 in. Feeder Line) Connector (1)  1)    The components of the N type-male are an N type-male body, an insert ring, a clamping nut, O-ring, and a heat shrink tube, and it is assembled using the wire stripper, trimming tool, spanner, etc. 2)    Using a stripping tool or a knife, strip the 1/2 in. feeder line by 1 in. (25.4 mm) from the end, as shown in the figure below. Trimming Tool Heat Shrink Tube [1.1 in. (28 mm)] Insert Ring N type-Male Body Clamping Nut 1/2 in. Feeder Line O-Ring 1 in. (25.4 mm)  1/2 in. Feeder Line Conductor 1/2 in. Feeder Line Jacket
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-9 2600-00F1W8GAA 4.0  Figure C.9  Assembling the N type-male (1/2 in. Feeder Line) Connector (2)    Trimming Tool 3)    Remove the 0.43 in. (11 mm) of the external conductor end and 0.39 in. (10 mm) of the jacket using a trimming tool.  Collet 4)    Insert the internal conductor into the deburring hole at the bottom of the trimming tool to trim it.  0.94 in.   (24 mm)  0.43 in. (11 mm)
 Ver.  ANNEX C. Connector Assembly C-10 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure C.10  Assembling the N type-male (1/2 in. Feeder Line) Connector (3) 5)    Insert the o-ring, clamping nut, insert ring and N type-male body to the stripped 1/2 in. feeder line in   this order. O-ring is inserted into the second groove from inside of outer insulator.  6)    Tighten the clamping nut and N type-male body inserted into the 1/2 in. feeder line firmly using a spanner.   The recommended torque for tightening the clamping nut and N type-male body is 306~510 lbf·ft (30~ 50 N.m). (Note that it should only be tightened by rotating the external body with the clamping nut in a fixed and stable position.) Insert Ring N type-Male Body Clamping Nut O-Ring Keep the fixed state
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-11 2600-00F1W8GAA 4.0  Figure C.11    Assembling the N type-male (1/2 in. Feeder Line) Connector (4)    Checking to carry out when assembling the N type-male connector   The shape, tool and assembly method may differ depending on the connector type and manufacturer. Make sure to check the user manual provided by the manufacturer before assembling. Clamping Nut 7)    Insert the heat shrink tube into the 1/2 in. feeder line fitted with the N type-male connector as shown in the Figure below. - Heat shrink tube: Φ 1.1 in., 3.94 in. (Φ 28 mm, 100 mm)  8)    Shrink the heat shrink tube inserted into the 1/2 in. feeder line using a heating gun. Heating Gun Heat Shrink Tube (1.1 in.)
 Ver.  ANNEX C. Connector Assembly C-12 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 C.6 Din type-male (1/2 in. Feeder Line) Below is the method for assembling the Din type-male connector to the 1/2 in. feeder line.  Figure C.12  Assembling the Din type-male (1/2 in. Feeder Line) Connector (1) 2)    Straighten the cable, then, using a suitable tool, strip it to the connector’s wire strip length.   When cutting the sheath, hold the cable firmly with one hand and cut the cable pulling the cutting   tool inwards with the other hand. Gently rotate the tool several times (do not pull it too hard), so that   the internal copper line is not damaged. 3)    Using a cutter, cut the sheath from the stripped edge to the end of the cable and completely strip the sheath. Cutting Tool Cutter Feeder Line 1)    The components of the Din type-male are an Din type-male body, pin, an insert ring, a clamping nut,   o-ring, and a heat shrink tube, and it is assembled using the wire stripper, trimming tool, wrench, etc.  4)    Insert the o-ring, clamping nut, insert ring, pin and Din type-male body into the stripped feeder line in   this order. Din Type-Male Body Pin Insert Ring Clamping Nut O-Ring Feeder Line Heat Shrink Tube
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-13 2600-00F1W8GAA 4.0  Figure C.13  Assembling the Din type-male (1/2 in. Feeder Line) Connector (2)    Checking to carry out when assembling the Din type-male connector     The shape, tool and assembly method may differ depending on the connector type and manufacturer. Make sure to check the user manual provided by the manufacturer before assembling. Spanner (keep the fixed state) 5)    Tighten firmly the clamping nut and Din type-male body inserted to the 1/2 in. feeder line using a wrench.   The recommended torque for tightening the clamping nut and Din type-male body is 30~50 N.m.   (Note that it should only be tightened by rotating the external body with the clamping nut in a fixed and stable position.) Clamping Nut 6)    Insert the heat shrink tube to the 1/2 in. feeder line fitted with the Din type-male connector; and shrink the heat shrink tube inserted into the feeder line using a heating gun. - Heat shrink tube: Φ 1.1 in., 3.94 in. (Φ 28 mm, 100 mm) Heating Gun Heat Shrink Tube Din Type-Male Body
 Ver.  ANNEX C. Connector Assembly C-14 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 C.7 Finishing the Connector Connection Part by Tape Finishing the connector connection part by tape (insulation tape, rubber tape, etc.) in the outdoor environment is as follows:    Figure C.14    Finishing the Connector Connection Part by Tape  Cable Tie Rubber Tape Insulation Tape 1)    Overlap the exposed part of the connector connection part using rubber tape (Keep a distance as the half size of rubber tape) and press it with your hands lightly to make rubber tape adhere well. 2)    Wrap the part where the rubber tape is attached using insulation tape two times or more. When cutting off the tape, cut it off neatly using a cutting device such as scissors or a knife. 3)    Bind the end part of the insulation tape using cable tie to prevent slips.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-15 2600-00F1W8GAA 4.0 C.8 How to Shrink the Heat Shrink Tube C.8.1 When Assembling a Connector to the Feeder Line Below is the procedure for shrinking the heat shrink tube.    Figure C.15  Shrinking the Heat Shrink Tube_Feeder Line (1) 1)    Prepare a 1/2 in. feeder line, heat shrink tube, and   heating gun to finish the cable using a heat shrink tube. 2)    Insert the heat shrink tube into the 1/2 in. feeder line, and then place the heat shrink tube at the end of the cutting area of the connector where the tool will be used. 3)    Set the heating gun to 482 to 572°F (250 to 300°C). Heat Shrink Tube (Jelly Type) 28/6 × 5.9 in. (150 mm)  1/2 in. Connector Heating Gun 1/2 in. Feeder Line  Cutting Area
 Ver.  ANNEX C. Connector Assembly C-16 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure C.16  Shrinking the Heat Shrink Tube_Feeder Line (2)  6)    Shrink the heat shrink tube until jelly appears at the end part of it (refer the Figure below) and finish it. 4)    Holding one end of the heat shrink tube with your hand, apply heat starting from the connector using the heating gun. 5)    Rotate the heating gun so that heat is evenly distributed to prevent that bubbles are generated or heat is concentrated to a specific part. Heat Shrink Tube Heating Gun Jelly
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-17 2600-00F1W8GAA 4.0 C.8.2 When Connecting a Connector to another Connector Below is the procedure for shrinking the heat shrink tube.  Figure C.17  Shrinking the Heat Shrink Tube_Connection between Connectors (1)  1)    Prepare a 1/2 in. feeder line, 7/8 in. feeder line, heat shrink tube, and heating gun to finish the cable using a heat shrink tube. 3)    Insert the heat shrink tube, placing connector part   (where 1/2 in. and 7/8 in. feeder line will be connected) in the center, and mark the center part. Heat Shrink Tube (Jelly Type) 38/12 × 11.81 in. (300 mm)   7/8 in. Feeder Line Connector 1/2 in. Feeder Line Heating Gun 2)    Inset the heat shrink tube to one end of the feeder line and connect the connector.
 Ver.  ANNEX C. Connector Assembly C-18 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure C.18  Shrinking the Heat Shrink Tube_Connection between Connectors (2) 4)    Set the heating gun to 482 to 572°F (250 to 300°C). 5)    Holding one end of the heat shrink tube with your hand, apply heat starting from the marked part at the center using the heating gun. 6)    Rotate the heating gun so that heat is evenly distributed to prevent that bubbles are generated or heat is concentrated to a specific part. Heat Shrink Tube Heating Gun
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  C-19 2600-00F1W8GAA 4.0  Figure C.19    Shrinking the Heat Shrink Tube_Connection between Connectors (3)  7)    Shrink the heat shrink tube until jelly appears at the end part of it (refer the figure below) and finish it. Jelly
 Ver.  ANNEX C. Connector Assembly C-20 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0    Check for Working with the Heat Shrink Tube   - If you work without holding one end of the heat shrink tube, the location of the heat shrink tube may be changed. Therefore, make sure to hold one end of it when applying heat.         - The connector part where 1/2 in. and 7/8 in. feeder line are connected must be the center of the heat shrink tube. After inserting the heat shrink tube, mark the center part.      - If jelly does not appear on the end of the heat shrink tube, it may mean that it is not shrunk properly. Apply heat until jelly appears using a heating gun.        Jelly
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  D-1 2600-00F1W8GAA 4.0 ANNEX D. Cleaning Optic Connector      D.1 Cleaning Optic Connector When connecting optical cable to the system, performance of system can be decreased or fails can occur if core section of optical connector is dirty due to dust or foreign material. Therefore, worker should clean the optic connector before connecting optic cable to the system to prevent this phenomenon. This manual describes the method that cleans optic connector when using the IBCTM Brand cleaner.    Caution When Connecting the Optical Cable     Check whether there is dust or foreign material on the cutting section of the connector core before connecting the optic cable, and keep this away from dust or foreign material.   If the cable is soiled with foreign material, do not blow to remove them. Make sure to clean the connector in accordance with the cleaning directions below.   When using Optic Connector Cleaner   When using optic connector cleaner, use the products shown in the example below or their equivalents.     Ex)    Manufacturer-USCONEC (http://www.usconec.com) - IBCTM Brand Cleaner (P/N: 9393): For LC-LC and MU Connector Cleaning - IBCTM Brand Cleaner (P/N: 9392): For SC Connector Cleaning - IBCTM Brand Cleaner (P/N: 12910): For ODC Connector Cleaning         Manufacturer-TheFibers (www.thefibers.com) - HuxCleaner 1.25 mm Type: For LC and MU Connector Cleaning - HuxCleaner 2.5 mm Type: For SC, FC and ST Connector Cleaning
 Ver.  ANNEX D. Cleaning Optic Connector D-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 D.2 IBCTM Brand Cleaner Method that uses IBCTM Brand Cleaner is as follows:  D.2.1 IBCTM Brand Type Cleaner (P/N 9393) Method that uses IBCTM Brand Cleaner for LC-LC and MU connector is as follows:  Figure D.1   Optic Connector Cleaner (IBCTM Brand Type Cleaner: P/N 9393)  Outer Shell [Optic Connector Cleaner Configuration] Nozzle Guide Cap Lock Button (for Extend Nozzle) [Nozzle Extension] [In Case of LC type Connector (Plug)] Guide Cap Guide Cap Cover [In Case of LC type Connector (Jack)] Guide Cap Lock Button (for Extend Nozzle)
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  D-3 2600-00F1W8GAA 4.0 Optic Module Cleaning (LC Type Jack) Figure D.2    Optic Module Cleaning (LC Type Jack)  Guide Cap 1)    To clean the optic module, remove the guide cap from the cleaner (P/N: 9393).   2)    Insert a cleaner guide cap to every core of the optic module. Clean it by pushing the outer shell toward the nozzle until you hear the sound of the detergent being sprayed. (Repeat once or twice.)    Outer Shell Nozzle Nozzle Outer Shell Optic Module [IBC Brand Cleaner: P/N 9393]
 Ver.  ANNEX D. Cleaning Optic Connector D-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Optic Cable Connector Cleaning (LC Type Plug) Figure D.3   Optic Cable Connector Cleaning (LC Type Plug)  Guide Cap Guide Cap Cover 1)    To clean the optic cable connector, open the guide cap cover from the cleaner (P/N: 9393).  2)    Insert a cleaner guide cap to every core of the optic cable connector. Clean it by pushing the outer shell toward the nozzle until you hear the sound of the detergent being sprayed. (Repeat once or twice.)    Outer Shell Nozzle Guide Cap Nozzle Outer Shell LC Type Connector [IBC Brand Cleaner: P/N 9393]
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  D-5 2600-00F1W8GAA 4.0 Measuring the Optical Output and Connecting the Optic Connector Figure D.4  Measuring the Optical Output and Connecting the Optic Connector  [Optic Powermeter] 1)    Check the optical output again using an optic power meter. 2)    If the optical output measurement result meets the reference value, clean the connector again and connect it. If the measurement result does not meet the reference value, discard the cable, replace it with a new cable, and then clean the new one and connect it to the system.    [LC/PC Plug]
 Ver.  ANNEX D. Cleaning Optic Connector D-6 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0   This page is intentionally left blank.
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  E-1 2600-00F1W8GAA 4.0 ANNEX E.  Cable Gland Assembly       Caution When Assembling Cable Gland   If the parts of a cable gland in the system are not correctly installed, outdoor air and moisture may flow into the system and cause corrosion, system fault, or serious fault to the cooling system. Therefore, assemble and finish the cable gland accurately.   Caution When Installing Cable in the Cable Gland   Only one cable of permitted specification (thickness) should be installed in the cable gland.   - The outdoor air or moisture may flow into the system if a cable that is thinner than the specification is used.   - If a cable is thicker than the specification or more than two cables are installed, the cable gland may be damaged.   Caution When Loosening or Tightening Cable Gland Nut  When assembling the cable gland or connecting it to a cable, make sure not to turn other parts (cable gland body) than a gland nut to loosen or tighten the gland. Turning the cable gland body may cause the influx of external air or moisture into the system, which may result in corrosion or system malfunction.           Cable Gland Nut Cable Gland Body Torque Wrench Torque Wrench
 Ver.  ANNEX E. Cable Gland Assembly E-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0   Use Torque Wrench When Tightening Cable Gland Nut   Tighten the cable gland nut using a torque wrench with standard torque.        E.1  Cable Gland Components The components of the cable gland are as follows.  Figure E.1    Cable Gland Components  By loosening the gland nuts outside the unit, the cable gland is dissembled into 3 parts as shown in the picture below. (Except for system-side fixing parts) Protection Cover  Cable Gland Nut  Rain-proof Filler Torque Wrench
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  E-3 2600-00F1W8GAA 4.0 E.2  Cable Gland Assembly and Cabling When assembling a cable gland, follow the below steps to prevent any moisture or foreign substance from coming in.  Figure E.2    Cable Gland Assembly and Cabling (1) 1)    Check the cable gland built on the unit to see whether it has the protection cover inside the cable gland nut as shown in the picture below (cross-section picture of outer wall of the unit), the same as the original factory configuration. 3)    Remove the protection cover and keep it carefully. [Side picture] Protection Cover Cable Gland Nut 2)    Separate the cable gland nut by loosening counterclockwise. Here, check the protection cover (circular transparent plate). Protection Cover Cable Gland Nut [When a cable gland nut is disassembled] Protection Cover [When the protection cover is removed]
 Ver.  ANNEX E. Cable Gland Assembly E-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure E.3    Cable Gland Assembly and Cabling (2) 4)    Separate the waterproof filler from the cable gland body. 6)    After installing the cable through the cable gland body, connect it to the system according to assembling standard and clean up the rest of the cable.  5)    Install the cable by passing it through the cable gland nut from outside to inside.  Rain-proof Filler [When the rainproof filler is disassembled] Cable Gland Nut Cable Inside Outside 7)    Put the rainproof filler on the cable inside the cable gland nut. At this time, widen the waterproof filler and wrap the cable around. Rain-proof Filler Cable Cable Gland Nut Grooves of Rain-proof Filler Inside Outside
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  E-5 2600-00F1W8GAA 4.0  Figure E.4    Cable Gland Assembly and Cabling (3) 8)    Push the waterproof filler into the cable gland body. There are bumps inside of a cable gland body and outside of a rainproof filler, which allow easy coupling while preventing slippery rotation. Align the bumps and push the rainproof filler into the cable gland body.  9)    Attach the waterproof filler into the cable gland body as shown in the picture below. Make sure it is pushed in completely. Rain-proof Filler Cable Cable Gland Nut Cable Gland Body  Bumps of Rain-proof Filler Rain-proof Filler Cable Gland Nut Cable Cable Gland Body X O 10) Attach the cable gland nut and the cable gland body together and tighten the nut clockwise. Cable Gland Nut Cable Cable Gland Body
 Ver.  ANNEX E. Cable Gland Assembly E-6 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 E.3  Unused Cable Gland Inspection and Assembly The unused cable gland should not be disassembled, and be kept in the original factory configuration. If the cable gland is disassembled, it should be assembled to the factory default by referring to the sequence of ‘Cable Gland Parts Configuration’.  Figure E.5    Unused Cable Gland Inspection and Assembly   Checking Assembly State of the Unused Cable Gland   All components of the unused cable gland must be secured in the original factory configuration. If the cable gland nut is fitted without the waterproof filler or the protection cover in place, reassemble them as illustrated in ‘Unused Cable Gland Inspection and Assembly’.   Inside of the System Outside of the System Cable Gland Washer Cable Gland Body Rain-proof Filler Protection Cover Cable Gland Nut System Frame
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-1 2600-00F1W8GAA 4.0 ANNEX F.  Pressure Terminal Assembly      F.1  Preparations The followings must be prepared to connect a pressure terminal to a cable.  Figure F.1    Preparations  [Cable Cutter] [Wire Stripper] [Handheld Compressor] [Hydraulic Press] [Heating Gun] [Marking Pen] [Cutter Blade] [Steel Ruler] [Scissors] [Cable] [Pressure Terminal] [Heat Shrink Tube]
 Ver.  ANNEX F. Pressure Terminal Assembly F-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 F.2  Pressure Reference Table The pressure reference table used to assemble a pressure terminal to a cable is shown below.  Table F.1    Pressure Reference Table for Pressure Terminal Category Copper tube length of a pressure terminal Number of pressure points mm In. Hand 11 mm or less 0.43 in. 1 Hand 12~15 mm 0.47~0.59 in. 2 Hand 16~23 mm 0.63~0.91 in. 3 Hand 24~32 mm 0.94~1.26 in. 4 Hand 33 mm or more 1.3 in. or more 5 Hydraulic 30 mm or less 1.18 in. or less 2 Hydraulic 31~47 mm 1.22~1.85 in. 3 Hydraulic 48~63 mm 1.89~2.48 in. 4 Hydraulic 64 mm or more 2.52 in. or more 5  Figure F.2    Pressure Reference Drawing (Handheld Compressor)  [1-spot] [2-spot] [3-spot] [4-spot] Unit: in. (mm) 0.43 (11) 0.18 (4.5) 0.47 (12) 0.59 (15) 0.63 (16) 0.91 (23) 0.94 in. (24) 1.26 (32) 0.63 (16) 0.18 (4.5) Copper Tube Starting Middle of Copper Tube Arbitrary Fixing Reference Points
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-3 2600-00F1W8GAA 4.0  Figure F.3    Pressure Reference Drawing (Hydraulic Press)  Unit: in. (mm) [2-spot] [3-spot] [4-spot] 1.18 (30) [4-spot] Copper Tube Starting Duplicate Pressure Arbitrary Fixing Reference Points 0.53 (13.5) 1.22 (31) 0.53 (13.5) 1.22 (31) 1.85 (47) 1.89 (48) 2.48 (63) 2.52 (64)
 Ver.  ANNEX F. Pressure Terminal Assembly F-4 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Table F.2    Compressor Specifications per Cable Thickness Cable Size (mm2) Press Size Small Handheld Press Large Handheld Press (AK-38, 100) Hydraulic Press (IZUMI Hexagonal Dies) 2.5 2 X X 4 2 X X 6 5.5 X X 10 8 8 X 16 14 14 16 25 22 22 25 35 38 38 35 50 X 60 50 70 X 80 70 95 X 100 95~300
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-5 2600-00F1W8GAA 4.0 F.3  Assembling Pressure Terminal The procedures for assembling a pressure terminal to a cable are as follows:  Strip the Cable Sheath Figure F.4    Stripping Cable Sheath (1) 4)    Put a cable into a clamp, locate a blade on a marking position, and push it into the sheath.  5)    Align the stripper to be perpendicular to the cable and rotate it more than two laps.  1)    After checking the inside length of a pressure terminal, mark the cable.  2)    Adjust the length of a cutter blade according to the sheath thickness of the cable.  3)    Push the clamp with a thumb a ccording to the cable size to secure a space for the cable.
 Ver.  ANNEX F. Pressure Terminal Assembly F-6 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  Figure F.5    Stripping Cable Sheath (2) 6)    Push the lever of the stripper to the right to turn its blade at 90°.  8)    Remove the sheath.  7)    Move the stripper up to the end of cable while maintaining the stripper to be perpendicular to the cable.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-7 2600-00F1W8GAA 4.0    Checking When Using A Wire Stripper   A wire stripper is used differently depending on its manufacturer or type. Therefore, refer to the user manual enclosed with the product.       The specifications and cautions of a wire stripper described in this manual are as follows:    Vender: Weidmuller   Model: Weidmuller-AM25 (Order No-9001080000)   Specifications: For outer diameter 0.24~0.94 in. (6~24 mm) PVC clothing Up to 4.5 mm clothing cutting depth    - To prevent the cutter blade of a wire stripper from touching the cable conductor, adjust the length of cutter blade by checking the cable sheath thickness.     - Make sure that the cutter blade goes into the cable sheath completely.   - Rotate the wire stripper perpendicularly to the cable.         [X] [O]
 Ver.  ANNEX F. Pressure Terminal Assembly F-8 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Fixing Pressure Terminal (Handheld Compressor) Figure F.6    Fixing Pressure Terminal_Handheld Compressor (1)  1)    Insert the conductor of the cable with the sheath stripped to the internal end of pressure terminal. For a ring type pressure terminal, push it in until the conduct comes out 1 mm from the end of the terminal.  2)    From the holes of handheld compressor, select one that fits to the pressure terminal.  3)  Insert the pressure terminal to the selected hole.  4)    Fix the pressure terminal  and cable  temporarily  so the position can be changed later by  pressing the compressor.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-9 2600-00F1W8GAA 4.0  Figure F.7    Fixing Pressure Terminal_Handheld Compressor (2)    Checking When Using A Handheld Compressor   A handheld compressor is used differently depending on its manufacturer or type. Therefore, refer to the user manual enclosed with the product.       The specifications and cautions of a handheld compressor described in this manual are as follows:   Vender: GALLEX   Model: GL-2045A-22   Specification: 5.5 mm2, 8 mm2, 14 mm2,   22 mm2 (JIS) 6 mm2, 10 mm2, 16 mm2, 25 mm2 (DIN)   5)    After complementary of the cable which is temporary fixed, align it to the hole and firmly compress the pressure terminal to secure fix it.  6)    Separate the pressure terminal from the handheld compressor. Press down the handle of compressor until a clicking sound is heard to be unlocked.
 Ver.  ANNEX F. Pressure Terminal Assembly F-10 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 Fixing Pressure Terminal (Hydraulic Press) Figure F.8    Fixing Pressure Terminal_Hydraulic Press (1) 1)    Among the dies of the hydraulic press, select one that fits to the pressure terminal.  Dies Hydraulic Press 2)    Assemble the dies to the pressing area of the compressor.    3)    Insert the pressure terminal into the pressing area and fix it slightly by aligning it to the end of cable sheath.
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-11 2600-00F1W8GAA 4.0  Figure F.9    Fixing Pressure Terminal_Hydraulic Press (2)  4)    Move the compressor lever up and down to press the pressure terminal firmly. 5)    Turn the top compressing lever clockwise and then push it down. When the pressing area of compressor is loosened, remove the pressure terminal.
 Ver.  ANNEX F. Pressure Terminal Assembly F-12 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0   Checking When Using a Hydraulic Press   A hydraulic press is used differently depending on its manufacturer or type. Therefore, refer to the user manual enclosed with the product.           The specifications and cautions of a hydraulic press described in this manual are as follows:   Vender: IZUMI   Model: IZUMI-EP-510B   Specification: Circular 32~160 (SQ)   Hex 14~325 (SQ)
 Ver.    Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  F-13 2600-00F1W8GAA 4.0 Assembling Heat Shrink Tube Figure F.10    Assembling Heat Shrink Tube 2)    Set the temperature of the heat gun to 356-392℉(180-200°C).  3)    Locate a heat shrink tube to cover the entire copper tube of the pressure terminal.  4)    Rotate a heat gun 360° to apply heat evenly to shrink the tube. (Because the pressure terminal and the cable is hot due to the heat of a heating gun, be careful not to have a burn.)  1)    After assembling a pressure terminal, move the heat shrink tube, inserted to the cable, to the end of pressure terminal copper tube. Heat Shrink Tube Pressure Terminal
 Ver.  ANNEX F. Pressure Terminal Assembly F-14 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  This page is intentionally left blank.
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  G-1 2600-00F1W8GAA 4.0 ANNEX G. Standard Torque      When you tighten the bolt, refer to the standard torque value below to prevent the equipment and bolt from damage and secure by tightening. When the torque value for each connection part is defined already, refer to the defined value.  Table G.1    Standard Torque Value for Tightening Bolts Bolt Spec. Torque Value (kgf.cm) Torque Value (N.m) Torque Value (lbf.ft) M3 4.08~6.12 0.40~0.60 0.29~0.44 M4 9.52~14.28 0.93~1.40 0.69~1.03 M5 20.0~30.0 1.96~2.94 1.45~2.17 M6 33.28~49.92 3.26~4.90 2.41~3.61 M8 82.4~123.6 8.08~12.12 5.96~8.94 M10 166.4~249.6 16.32~24.48 12.03~18.05 M12 292.0~438.0 28.64~42.65 21.11~31.67  Table G.2    Brass Bolts Torque Value Bolt Spec. Torque Value (kgf.cm) Torque Value (N.m) Torque Value (lbf.ft) M6 29.98 ± 10 % 2.94 ±10 % 2.17 ± 10 % M8 64.26 ± 10 % 6.3 ± 10 % 4.16 ± 10 %    Checking Standard Torque Value   Torque value can be different, defending on the material, characteristic and specification of the equipment and fastener. Make sure to check the proper torque value for each specification of the equipment and fastener.
 Ver.  ANNEX G. Standard Torque G-2 © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0  This page is intentionally left blank.
 Ver.  Mobile WiMAX/TD-LTE Smart MBS, U-RAS Flexible V2 RRH-B4 Installation Manual © SAMSUNG Electronics Co., Ltd.  I 2600-00F1W8GAA 4.0 ABBREVIATION      C CPRI  Common Public Radio Interface  D DU  Digital Unit  E eNB  evolved UTRAN Node-B  L L9CA  LTE eNB Channel card board Assembly LTE  Long Term Evolution  M MGB  Main Ground Bar MIMO  Multiple-Input Multiple-Output  R RET  Remote Electrical Tilt RF  Radio Frequency RRH  Remote Radio Head  T TGB  Tower Ground Bar  U UADU  Universal Platform type A Digital Unit UAMA  Universal platform type A Management board Assembly
 Ver.  ABBREVIATION II © SAMSUNG Electronics Co., Ltd. 2600-00F1W8GAA 4.0 V VSWR  Voltage Standing Waveform Ratio
   MPE Information ⓒ SAMSUNG Electronics Co., Ltd.    Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 300 cm during normal operation. The gain of the antenna is 17.0 dBi.The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
 Ver.    2600-00F1W8GAA 4.0      Mobile WiMAX/TD-LTE Smart MBS,   U-RAS Flexible V2 RRH-B4 Installation Manual  ©2012 Samsung Electronics Co., Ltd. All rights reserved.  Information in this manual is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated, transcribed or duplicated by any form without the prior written consent of SAMSUNG. Information in this manual is subject to change without notice.