Salto Systems S L G90 GEO Cylinder- RFID Electronic Cylinder Lock User Manual

Salto Systems S.L GEO Cylinder- RFID Electronic Cylinder Lock Users Manual

Users Manual

inspiredaccessSALTO GEO Cylinder | the next generation of electronic cylinder lockFully integrated with the SALTO XS4 platform, GEO is a versatile, cost effective solution and its compact size and easy installation makes it the ideal electronic locking system for almost any type of door.European cylinder - GxExUser Manual
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual2CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.INDEXPRODUCT DESCRIPTION  3WHATS ON THE BOX   3ACCESSORIES 4SALTO GEO RANGE  4MODELS 4DIMENSIONS 4CERTIFICATIONS 5Declaration of Conformity CE  5Protection against access to hazardhous areas, resistance against ingress of foreign particules and detrimental entry of water  5Mechanical certications against vandalisme  5Fireproof  certications   5TECHNICAL DATA  5ACCES CONTROL FEATURES  6OPENING MODES  6OPERATION OF THE CYLINDER  6INSTALLATION 7PROGRAMMING 9BATTERIES 9 Low battery status.  9 Battery  failure.  9 Change the batteries  10SALTO GEO SIGNALS  11 Access  granted  11 Card  rejection  11 Access time out  11 Low battery status  11 Battery changed (reset of the electronics)  12 Access granted + Toogle (ROM or RW systems)  12 End Toogle (ROM or RW systems)  13 Gear  error  13 Security error  13
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual3CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.SP301585 SP3030577 SP301582-10 SALTOGEOGRIPA SALTOGEOGRIPH SP201587PRODUCT DESCRIPTIONSALTO GEO cylinder is a battery operated electronic cylinder that brings all the advantages and benets of an access control without wiring the door reducing installation costs and allowing you to control and manage virtually anykind of door.The SALTO GEO cylinder European prole is specially designed to t most Euro prole doors that are equipped with a European prole cylinder mortise lock. A wire free fully stand alone electronic access control solution, it is suitable for installation in almost every type of wooden door including antique or listed wooden doors, metal and metal framed doors and glass doors.The key is always to be stored securely so that it is accessible only to the authorised person.If a key gets lost, the electronic cylinder is to be replaced immediately or, by changing of the codication put to a new coding respectively to block/delete the coding of the lost key.WHATS ON THE BOX When you purchase a SALTO GEO electronic Cylinder you get:•  SALTO GEO electronic cylinder•  1 lithium battery CR2type•  Installation guide•  1 M5 screw to x the cylindor onto the mortise lock•  1 Knob blocking screewFor the mantainance of the cylinder in order to perform replacemnt of bat-teries or the installation of double knob cylinders, electric swith cylinders SALTO Recommends to purchase the SALTO Geo Installation tool (SP220764) sold separately.ACCESSORIES•  SALTO 2,5 mm Allen key for SALTO GEO to remove the thumbturn. (SP301585)•  SALTO 2 mm Allen key for SALTO GEO to remove the knob. (SP3030577)•  SALTO CR2 battery for SALTO GEO cylinders. (SP301582-10)•  SALTO Geo cylinder grip A. (SALTOGEOGRIPAx)•  SALTO Geo cylinder grip H. (SALTOGEOGRIPHx)•  SALTO euro cylinder measuring key for installers (PZ). (SP201587)The product should not be modied in any way except in accordance with those modications described in the instructions
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual4CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.SALTO GEO RANGEModelsE1 = Half Euro profile cylinder. GxE11xxxxxE2 = Euro profile cylinder with thumbturn. GxE21xxxxxE3 = Euro profile double cylinder, double knob.  GxE31xxxxxDimensionsE1 = Half Euro profile cylinder. GxE11xxxxxE2 = Euro profile cylinder with thumbturn. GxE21xxxxxE2 = Euro profile cylinder with thumbturn Antipanic function. GxE21xxxxxAE3 = Euro profile double cylinder, double knob.  GxE31xxxxxGxE3GxE1 GxE2le 1038Ø4338Ø43le 10Lle liL4338Øle liL38Ø43le liL4338Øle liL38Ø43le liL38Ø43*leliL38Ø4310 1733Profile cylinder PZPanic Functionle 30/10030/10038Ø43le liL38Ø4312 h20°20°60°60°12 h120°120°Panic Function cylinder•  The cylinder has a mechanism to ensure that the cylinder cam re-sets to a position where it doesn’t interfere in the lock operation. •  The cam’s position is corrected from 12 h +/- 120º to 12 h+/-120º. •  The panic function requires a cylinder minimum interior length (li) of 35mm.•  The panic function is not compati-ble with double reader cylinder.
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual5CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.CERTIFICATIONSDeclaration of Conformity CE  Use of radio frequency spectrum    ETSI EN 302 291-1 V1.1.1 (2005-07)    ETSI EN 302 291-2 V1.1.1 (2005-07)  Electromagnetic Compatibility    ETSI EN 301 489-1 (2011-09)    ETSI EN 301 489-3 (2002-08)  Security requirements    EN 60950-1 (2007)Following the provisions of the directive 2004/108/CE (Electromagnetic Compatibility) and the directive 2006/95/CE (Low Voltaje).Protection against access to hazardhous areas, resistance against ingress of foreign particules and detrimental entry of water   IP protection: IP56Mechanical certications against vandalisme  EN1303  SKG*** TECHNICAL DATA Current required: 1 Lithium standard battery CR2 Environmental conditions:  -20ºC / 60ºC  Number of openings: Up to 40,000 on 1 battery Access control systems:       ROM System - Software required SALTO Pro Access ROM    RW System - Software required SALTO Pro Access RW or HAMS RW
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual6CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.ACCES CONTROL FEATURESOpening modes Standard:  locked at all times. Need of a valid card to get access. Automatic openings: 8 pairs of “hands free”(no card needed to access) timed    lock and unlocks per day subject to calendar and time periods (ROM and RW    systems only). Toogle: present valid card to lock, present valid card to unlock  (ROM and RW systems).  Timmed Toogle:  present valid card to lock, present valid card to unlock de   pending on schedules to switch between standard mode and Toogle mode  (ROM and RW systems).Operation of the cylinderTimezonesEach user can be assigned to a calendar and a time table consists of up to 8 different time intervals with a resolution of 10 minutes assigned to each day of the week. You can also distinguish between holidays, special days and working days.Event Auditor - Authorized access events auditor registration, denied access events auditor registration, system maintenance events auditor registration (low battery, PPD connection, ...) and automatic actions events auditor registration (automatic opening, ...)- Each event is logged: Event type, user, date and time of the event.- Permanent events restration. Non-volatile memory of the last X events (see table).Maximum number of door per systemMaximum events on lock auditTimezonesTimeperiodsCalendars in systemUser groups Maximum number of user per door 1000  4000000 16000  64000 680 1000 30 256 20  2564 256unlimitedunlimitedunlimitedManagement software ProAccess ROMProAccess HAMS(available SQL)unlimitedZones in SystemROM SystemR&W SystemPresent a valid card   Turn the knob to retrieve the latch and deadbolt
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual7CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.INSTALLATION  1 - unpack 2 - Remove the knob to connect the battery  2 - Remove the battery protection  3 - Prepare the cylinder for the installation on the door         (for model GxE2)SP220764 (not included)2,5 mm allen key(not included)PH2 screw driver(not included)2 mm allen key(not included)Knob blocking screw(included)CR2 battery(included)CLICK !PAIRED*CLICK ! Important:  the knob is uniquely paired to the cylinder, and will not work if you switch in a different SALTO knob.  2.5 mmMax.Le+3Min.LeLiLe
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual8CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.INSTALLATION  3 - Prepare the cylinder for the installation on the door (for model G9x3)   Remove one of the knobs in order to be able to fit the cylinder For a correct installation  4 - x it to the door  5 - Screw it to the mortise lockPAIRED*360ºx32 mm allen key(not included)External KnobFor a correct installation the body need to excel 3mm from the door surfaceAt this point do not close the door without having programmed the cylinder rstModel GxE2 Model GxE3Doorlile0 - 3mm max.
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual9CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.PROGRAMMINGTo grant or deny access permissions are used the right SW license. Once you update the system conguration:- ROM System updates the access permissions on the cylinders using a PPD.- RW System is not necessary to update the cylinders with the PPD.  The system allows elec-tronic cylinders to read, receive and write information via its operating smart cards or ‘intelligent’ keys. This data is captured from the cards at SVN on-line hot spots located at strategic points around the building.The “online points” uploads and downloads user related information that is then used to permit, control or deny access.BATTERIES  Low battery status.The low battery status can be recognised by 4 slow and low pitched warning tones. If these war-nings are ignored then the batteries will fail.  Battery failure.In the case of complete battery failure the product fails both safe and secure, i.e. the outside handle fails “locked” to avoid intrusions, the inside handle fails “open” to permit emergency openings. Note that once the cylinder is powered again with new batteries all the keys that were programmed into the cylinder will still work as before, because the memory is retentive.WARNING: The electronic cylinders needs to be updated with the PDD to recover the hour.“The product should not be modied in any way except in accordance with those modications described in the instructions”BEEEEP BEEEEP BEEEEP BEEEEP
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual10CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.BATTERIES  Change the batteriesThe new SALTO Geo Cylinder, permits to change the batteries without needing to open the door, so in case of a battery failure you will be able to change the batteries using the SP220764 tool. 1 - Remove the knob 2 - Remove the battery  3 - Replace a new battery  4 - Mount the knobONLY NEW BATTERYCLICK !
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual11CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.SALTO GEO SIGNALS  Access grantedPresent a valid user key and get the access granted.  Card rejection    Present a user key that has no access to the door. Access time outAfter presenting a valid user card that has access to the door and open the door, the cylinder will remain engaged for a few second. the end of the time out will be then activated. Low battery statusAfter presenting a valid user card that has access to the door and opening the door, the cylinder will show 4 light red signal and then grant the access. BEEPBEEPBEEP3 short high pitched beeps3 short green lightsAcoustic signal  Optical display BEEP1 short high pitched beeps1 long red lightAcoustic signal  Optical display BEEP2 short low pitched beeps2 short red lightAcoustic signal  Optical display BEEP4 short low pitched beeps4 short red lightAcoustic signal  Optical display BEEPBEEPBEEPBEEP
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual12CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.SALTO GEO SIGNALS  Battery changed (reset of the electronics)Each time you change the batteries, the electronic will do a reset of the electronic. The cylinder memory will not be erased. To show this reset the cylinder will show an orange light with a lite sound.  Access granted + Toogle (ROM or RW systems)  After presenting a valid user card with Toogle credentials, the SALTO GEO cylinder will start the Toogle mode. This will be shown by a mix of high and low pitched beeps and 4 green lights. BEEP3 short high pitched beeps3 orange lightAcoustic signal  Optical display BEEP1 low pitched1 high pitched 1 low pitched1 high pitched beeps4 green lightAcoustic signal  Optical display BEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEP
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual13CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.SALTO GEO SIGNALS End Toogle (ROM or RW systems)When Toogle mode is activated and you presenting a valid user card with Toogle credentials, the SALTO GEO cylinder will end the Toogle mode. This will be shown by a green light followed by a red light.  Gear errorAfter presenting a valid user card that has access to the door, the cylinder shows a continuous orange blinking plus a combination of acute and high pitched beeps with a nal long orange light, that mean that the cylinder gear is broken. Security errorWhen the cylinder shows continuous blinking light nished and a combination of high pitched beeps with a nal long red light it means that the knob and the cylinder are not paired and they can not be mounted together. please the correct knob with the corrrect cylinder.     BEEP1 high pitched beep and 1 low pitched beep1 short greenand one long red lightAcoustic signal  Optical display BEEP high pitched beeps + low pitched beepcontinuous orange lights + long orange lightAcoustic signal  Optical display BEEPhigh pitched beeps + low pitched beepcontinuous orange lights + long red lightAcoustic signal  Optical display BEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEPBEEP
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual14CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.
Manual_SALTO_GEO_VDS_ENG_08-13www.saltosystems.comSALTO Systems - SALTO Geo user manual15CONFIDENTIAL - This document contains condential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.
8SALTO SYSTEMS MEXICO, Cancúnwww.saltosystems.comSALTO SYSTEMS BELGIUM, Brusselswww.saltosystems.beSALTO SYSTEMS CANADA, Montrealwww.saltosystems.caSALTO SYSTEMS GERMANY, Gevelsbergwww.saltosystems.de© SALTO Systems –  Manual_SALTO_GEO_ENG_08-13SALTO SYSTEMS AUSTRALIA,  Sydneywww.saltosystems.com.auSALTO SYSTEMS ASIA,  Singaporewww.saltosystems.comSALTO SYSTEMS US, Atlanta www.salto.usSALTO SYSTEMS AUSTRALIA, Melbournewww.saltosystems.com.auSALTO SYSTEMS NORWAY, Oslowww.saltosystems.noSALTO SYSTEMS CZECH REPUBLIC, Praguewww.saltosystems.comSALTO SYSTEMS SLOVAKIA, Bratislavawww.saltosystems.comSALTO SYSTEMS POLAND, Warsawwww.saltosystems.plSALTO SYSTEMS FINLAND, Helsinkiwww.saltosystems.fiSALTO SYSTEMS DENMARK,Kalundborgwww.saltosystems.dkSALTO SYSTEMS NETHERLANDS, Amsterdamwww.saltosystems.nlEVVASALTO ACCESS AB SWEDEN, Stockholmwww.evvasalto.seSALTO reserves the rights to modify technical specifications, designs, and performance without notice.The paper used is FSC certifiedSALTO SYSTEMS MIDDLE EAST, Dubai - UAEwww.saltosystems.comSALTO SYSTEMS PORTUGAL, Oportowww.saltosystems.comSALTO SYSTEMS SPAI N (HQ),www.saltosystems.comSALTO SYSTEMS UK, Banburywww.saltosystems.co.ukSALTO SYSTEMS FRANCE,  Pariswww.saltosystems.frSALTO SYSTEMS SWITZERLAND, Eschilkonwww.saltosystems.chSALTO SYSTEMS ITALY, Bolognawww.saltosystems.itLearn more about innovative SALTO access control technologies through this QR Code using your smart phone to  link to the SALTO website.
ED0‐221405   FCC Compliance Statements (FCCID: UKCAE9, UKCAE9W, UKCL90, UKCG90, UKCRPOE, UKCNRF, UKCA9XX, UKCA9XW)  This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  Canadian Compliance Statement (IC: 10088A-AE9, 10088A-AE9W, 10088A-L90, 10088A-G90, 10088A-RPOE, 10088A-NRF, 10088A-A9XX, 10088A-A9XW)  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Canadian Compliance Lable (IC: 10088A-AE9, 10088A-AE9W, 10088A-L90, 10088A-G90, 10088A-A9XX, 10088A-A9XW) Industry Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B)   EU Compliance Statement   EN  Hereby, Salto Systems S.L. (Arkotz Kalea (Pol. Lanbarren), 9 – 20180 Oiartzun– Spain), declares that this access control equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC (R&TEE). You will be able to find a copy of the original declaration of conformity at the following Internet address: http://www.saltosystems.com/declarations  ES  Por medio de la presente Salto Systems S.L. (Arkotz Kalea (Pol. Lanbarren), 9 – 20180 Oiartzun– Spain) declara que este equipo de control de accesos cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE (R&TEE). Podrá encontrar una copia de la declaración de conformidad original en la siguiente dirección de internet: http://www.saltosystems.com/declarations  FR  Par la présente Salto Systems S.L. (Arkotz Kalea (Pol. Lanbarren), 9 – 20180 Oiartzun– Spain) déclare que l'appareil access control equipment est conforme aux exigences essentielles et aux autres dispositions pertinentes de la Directive 1999/5/CE (R&TEE). You will be able to find a copy of the original declaration of conformity at the following Internet address: http://www.saltosystems.com/declarations   DE  Hiermit erklärt Salto Systems S.L. (Arkotz Kalea (Pol. Lanbarren), 9 – 20180 Oiartzun– Spain), dass sich das Gerät access control equipment in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG (R&TEE). You will be able to find a copy of the original declaration of conformity at the following Internet address: http://www.saltosystems.com/declarations  DU  Hierbij verklaart Salto Systems S.L. (Arkotz Kalea (Pol. Lanbarren), 9 – 20180 Oiartzun– Spain)dat het toestel access control equipment in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG (R&TEE). You will be able to find a copy of the original declaration of conformity at the following Internet address: http://www.saltosystems.com/declarations  Mechanical Warnings  In order to assure a good performance for the device, Salto recommends to use a certified mortise lock and make sure that it is in good condition. Do not knock the device while mounting, if necessary, loose the trims fixation. Do not bring the device into contact with oil, paints or acids. Do not paint the door with the mortise lock fixed to the door. CLEANING THE ELECTRONIC FURNITURE: You can use a damp cloth from soapy water. Never use abrassive soaps or sprays.It is important to clean stainless steel regularly.   Legal Warnings  SALTO shall not be liable for any losses, personal damages or claims arising out of, or in connection with t he wrong fitting of the cylinders o r bad programming that can cause blocking of entries and exits i.e. blocking entrance, exit of Injured or people in danger. Do you have the programming keys or management software (not included in this box)? If not, then take note that when the door is closed without having been programmed it will automatically lock, and can only be opened with a Portable Programing Device. If in any doubt, please contact your supplier or visit our Web site: www.saltosystems.com According to the fourth point on the SALTO SYSTEMS LIMITED WARRANTY document, the warranty does not cover product failures due to repair installations, modifications or improper service performed by non-Salto authorised persons. The user is not allowed to disassemble the inner electromechanic structure in the SALTO furniture. (for instance, loosening the torx screws) In the case of a user intended intervention at the inner parts, the user will lose any warranty right from SALTO.     Copyright © 2013 SALTO Systems N20371