SOYAL TECHNOLOGY AR-837 Access Controller User Manual

SOYAL TECHNOLOGY CO., LTD. Access Controller

User manual

SOYALACCESS CONTROL SYSTEM®AR-837V140217    B. 或12P1 P2P4 P7P5 P687654321876543212143212 1321P2P3P6P5P7P1P412345678910CN6CN5CN7CN8CN3CN13CN4Contents2User GuideThe communication wires and power line should NOT be bound in the same conduit or tubing.Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may cause a  malfunction in the reader.The standard installation: Door relay and lock use the same power supply, and reader should use another independent power supply.Use AWG 22-24 Shielded Twist Pair to avoid star wiring, CAT 5 cable for TCP/IP connection1.Tubing:2.Wire selection:3.Power supply:1Products 3Terminal Cables 4ToolsNoticeConnector Table (1)Wire Application Wire Color DescriptionLock Relay 1Blue White (N.O.)DC24V1Amp2Purple White(N.C.)DC24V1AmpLock Relay COM 3White (COM)DC24V1AmpDoor Contact 4Orange Negative Trigger InputExit Switch 5Purple Negative Trigger InputAlarm Relay 6Gray N.O./N.C. Optional (by jumper)Power 7Thick Red DC 12V8Thick Black DC 0VCable:      CN4P1Wire Application Wire Color DescriptionRS-485 for LiftController1Thick Green RS-485(B-)2Thick Blue RS-485(A+)Cable:      CN6P4 Wire Application Wire Color DescriptionDoor Bell 1Black White Transistor Output Max. 12V/100mA (Open Collector Active Low)2Black DC 0VCable:   7 CN13P7Wire Application Wire Color DescriptionBeeper 1Pink Beeper Output 5V/100mA, LowLED 2Yellow Red LED Output 5V/20mA, Max3Brown Green LED Output 5V/20mA, MaxDoor Output 4Blue White Transistor Output Max. 12V/100mA (Open Collector Active Low)Wiegand 5Thin Green Wiegand DAT: 0 Input6Thin Blue Wiegand DAT: 1 InputWG Door Contact7Orange Negative Trigger InputWG  Exit Switch 8Purple Negative Trigger InputP2Cable:      CN5A-1.Surface Mounted: Use a screwdriver to screw the mounting plate to the wall. A-2.Embedded: To dig a hole for                       837(EF):128mmx109mm; and then, use a screwdriver to screw the mounting plate to the wall.  Pull cable ends through the access hole in the mounting plate.  Attach AR-837(E) or AR-837 (EF) to the mounting plate and install screws (supplied) into the holes at the bottom with the allen key.  Apply power. LED (green) will light up with one beep.InstallationAR-837 (EF):FingerprintWire Application Wire Color DescriptionReserved 1 Red  -- Security trigger signal 2Purple Security trigger signal OutputArming 3 Red White Arming OutputDuress 4 Yellow White Duress OutputP6Cable:      CN8Wire Application Wire Color DescriptionAnti-Tamper Switch 1Red N.C.2Orange COM3Yellow N.O.P5Cable:      CN3Water proof StripScrewsA-1.Surface         MountedA-2.Embedded
V140217       12  0714 : 49 : 04WEDDuty : 014 : 49 : 04WEDDuty : 012/07       LCD / Biometrics Access Controller Front Panel & Indicator1.  System will automatically exit Programming Mode when inactivating for 30 seconds.2.  LED status indicates controller’s mode and status. OK (green) – blinking constantly when operating in Programming Mode                     – or ashing an existed card in card learn mode, it comes 2 beeps                       warning and LCD panel displays “Same Card: user address / card                        number” Error (red) – invalid card with 2 beeps warning and LCD panel displays “Card                      Number Err!”                   – or in anti-pass-back mode, when violates the access, it comes one                      beep warning and LCD panel displays “Anti-pass Error!”  Arming (green) – arming on status Alarm (red) – any abnormal condition occurs3.  Keypad will be locked up 30 sec. when incorrect pin code or master code is constantly entered.4.  Maximum error input of pin code and master code can be changed via the software 701Server (default: 5 times)Power(Green)Alarm(Red)Arming(Green)OK(Green) Error(Red)In processing(Green) Networking  : / and     interactively ash between the Month and DAY.                       [e.g.] 12/07←→12   07Stand-alone : No ashing   [e.g.] 12/07(←Reference to picture)Connect to Electric BoltWiring DiagramEXIT12345678E12VGNDExit Switch12VGND12VGNDN.O.GNDN.O.COMPB12VGNDP1Electric BoltController RTEPOWER12VDCPOWER12VDCEXIT12345678N.C.COMPB12VGND12VGND12VGND12VGNDN.O.GNDP1Controller RTEPOWER12VDCPOWER12VDCMagnetic LockConnect to Magnetic Lock Connector Table (2): OptionalWire Application Wire Color DescriptionTCP/IP Module 1Black DC 0V2Red DC 3.3V3Black DC 0V4Blue RSTN5Green IRQN6Purple NSS7 Brown MISO8 White MOSI9Blue CLK10 Black DC 0VWire Application Wire Color DescriptionHID RF Module 1OrangeANT 12PurpleANT 23Black DC 0V4Red DC 5V5Blue Wiegand DAT: 1 Input6Green Wiegand DAT: 0 Input7White   --Wire Application Wire Color DescriptionVoice Module(*Required speaker  8Ω / 1.5W (Max.    2W)1Black DC 0V2YellowTX3White TE4Orange RX5Red DC 5V6Blue  --Cable:      CN7 Cable:      Cable:      CN9P3 P8P9
SOYALACCESS CONTROL SYSTEM®AR-837V140217    N.C.N.O.COMCTL12VEEBZRLEDGLEDWG 0WG 112VGND11122233344455566677788812345612VGNDExit Switch12VGND12VGND12VGND12VGND12VGNDPBPBCOMCOMN.O.N.O.P2P1P1P1BZRLEDGLEDDoor OutputWG 0WG 1WG-DSWG-PB78EXIT123456781   2   3N.C.N.O.COMCTL12VGNDPB12VGND12VGNDN.O.12VGND12VGNDDDRP1P6 AR-721RB412VN.C.EXITRTEEXIT1234567812VGND12VGNDPBCOMN.C.P1EXIT EXITController  Controller ReaderRTERTERTERTEPOWER12VDCPOWER12VDCPOWER12VDCPOWER12VDCPOWER12VDCPOWER12VDCPOWER12VDCElectric StrikeDoor ContactStrengthen security with AR-721RBElectric Bolt Electric BoltElectric BoltFire EmergencyTransistorIN4007TransistorIN4007Connect to ReaderMagnetic LockConnect to Electric Strike Connect to Door ContactEXIT1234567812VGND12VGND12VGNDN.O.GNDN.O.COMPB12VGNDP1Controller RTEPOWER12VDCPOWER12VDCElectric Strike12345678N.C.N.O.COMCTL12VDoor ContactALM12VGND12VGND12VGND12VGNDN.C.P1Controller POWER12VDCPOWER12VDCAlarmRelay Output Module Door ContactIn the event of a re emergency, all doors can be opened by pressing the Fire Emergency switch.
V140217      LCD / Biometrics Access Controller E. PIN CodeAccess programming mode →     User Setting →     Password → Input 5-digit user address → Input 4-digit PIN (0001~9999) → Succeeded  Or via 701Client set it on  Users  screen21C. Initial setupNode ID of Reader SettingAccess programming mode →     Parameters[1] →     Node ID → Input New Node ID : 1~254 (default value:001) → Main Door Number : 0~255 → WG1 Door Number : 0~255 → Show UID (0=No, 1=WG, 2=ABA, 3=HEX) → Enable DHCP(0:No, 1:En, 2=Exit) → Succeeded3 1Language SettingAccess programming mode →     Tools →     Language →      EN → Succeeded → Initial system...5 1 0ProgrammingB. Entering and Exiting Programming ModeExitingPress the             repeatedly →      Quit or       Quit and Arming (Please refer to alarm / arming setting)6Changing the Master CodeAccess programming mode →     Tools →     Master Code → Input the 6-digit new master code → Succeeded5 2A. Keyboard Lock/ UnlockLock/ UnlockPress       and        simultaneously to lock keyboard. Press simultaneously again to unlock.EnteringInput      123456      or      PPPPPP[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input     876112     → Access programming modeP.S.If no instruction is entered within 30 sec., it will automatically leave the programming mode.7Access programming mode →     Add/Delete →     Add -> RF-Learn → Input 5-digit user address → Input Tag Units(pcs)  → Close Tag into RF Area※If the batch of tags are Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with       the lowest number to the controller for adding all the tag data; otherwise, the tags must be presented to the controller individually1 2Adding Tag by RF Learn FunctionTag InformationSITE CODECARD CODESITE CODECARD CODE※ User capacity: 16384 (00000~16383)Access programming mode →     Add/Delete →     Add -> Card ID → Input 5-digit user address → Input Site Code → Input Card Code1 1Adding Tag by Tag IDAccess programming mode →     Add/Delete →     Delete -> Addr → Input Start address → Input End address1 5Deleting User AddressAccess programming mode →     User Setting →     Access Mode → Input User Address → 0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN2 2Setting up the access modeAccess programming mode →     Add/Delete →     Delete -> ID # → Input Site Code → Input Card Code1 6Deleting Tag by Tag IDAccess programming mode →     Add/Delete →     Suspend -> Addr → Input Start address → Input End address1 3Suspend User AddressAccess programming mode →     Add/Delete →     Suspend -> ID # → Input Site Code → Input Card Code1 4Suspend Tag by Tag IDAccess programming mode →     Add/Delete →     Delete -> Addr → Input Start address → Input End address1 7Recover User AddressAccess programming mode →     Add/Delete →     Delete -> ID # → Input Site Code → Input Card Code1 8Recover Tag by Tag IDD. Adding and Deleting Tag
SOYALACCESS CONTROL SYSTEM®AR-837V140217   H. Arming PasswordJ. Duress CodeK. Terminal PortI. Arming Delay TimeAccess programming mode →     Parameters[1] →     Arming PWD → Input 4-digit PIN (0001~9999; Default: 1234) → Succeeded  Or via 701Server and set it on  AR-829E  screen38Or via 701Server to set it on  AR-829E-V5  screen※Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a        warning signal.Access programming mode →     Parameters[2] →     Duress Code → 4 sets (select one) → Input 4-digit PIN (0001~9999) → Succeeded  4 7Access programming mode →     Tools →     Terminal Port → 0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) → Baud Selection (default value:9600) → Succeeded  5 4L. Setting up the alarm / armingConditions:1. Arming enabled2.Alarm system connectedSituations:1. Door is open overtime: Door is open longer than door relay time plus door close time.2. Force open (Opened without a valid user card): Access by force or illegal procedure.3. Door position is abnormal: Happening when power is off and then on again, besides, reader was on arming before power went off.Enable/Disable the arming status:Standby ModeAccess Programming modeCard only Card or PIN Card and PINOpen the doorPresent the tag to reader → Input 4-digit arming PWD →Input user address → Input 4-digit individual PWD →      → Input 4-digit arming PWD →Present the tag to reader → Input 4-digit individual PWD →      → Input 4-digit arming PWD →Enable: Access programming mode →     Quit & Arming7Disable: Access programming mode →     Quit6No open the door     → Input 4-digit arming PWD → Present the tag to readerAccess programming mode →     Parameters[1] →     ArmingDelayTm → Enter armed sta. Delay time(Sec), Range:000~255;Armed pulse out-put time (10ms) ,Range:000~255 → Succeeded  37※ [Use FP] can substitute for [Induct valid card].F. Adding / Deleting Fingerprint AddingAccess programming mode →     User Setting →     Enroll FP → Key in 5-digit user address →1 or 2 different ngers on the sensor lens → SucceededP.S. The AR-837EF needs to collect twice for each ngerprint.2 6DeletingAccess programming mode →     User Setting →     Delete FP → Key in 5-digit user address → SucceededP.S. If you want to delete all users’ FP, key in 999992 7#G. Access ModeAccess programming mode →     User Setting →     Access Mode → Key in 5-digit user address (00000~08999) → 0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN (837EF: → Finger Identify: 0: Must ; 1: Ignore )→ Succeeded  22Access Mode Finger Identify (837EF Only) Result  (837EF Only)Hardware 701Client Hardware 701Client0:Invalid0: Must        Just ngerprint       Just card control  Invalid User1: Ignore        Just ngerprint       Just card control1:Card0: Must        Just ngerprint       Just card control  Finger+Card1: Ignore        Just ngerprint       Just card control 1. Card Only 2. Finger Only2:Card or PIN0: Must        Just ngerprint       Just card control 1. Finger+Card 2. Finger+PIN 3. Card+Finger+PIN 4. Card+Finger+Card 5. PIN+Finger+PIN 6. PIN+Finger+Card1: Ignore        Just ngerprint       Just card control 1. Card Only 2. PIN Only 3. Finger Only3:Card and PIN0: Must        Just ngerprint       Just card control  Finger+Card+PIN1: Ignore        Just ngerprint       Just card control 1. Card+PIN 2. Finger+PIN
V140217   LCD / Biometrics Access Controller O. Alarm Clock (for Factory)P. OpenZoneQ. Open TimeZoneHardware installationM1BoardHorn M212345678N.C.N.O.COMCTL12VALM12VGNDGNDP1Output to M1 and M2Mike deviceMike deviceMusic BoxMusic Box Mike's sound wireMike's sound wireDC 12V Relay BoardController POWER12VDCAccess programming mode →     Tools →     Daily Alarm → Set (00~15) → Set Start Tm (24 Hours) ; Set Effect Sec. (Seconds as the bell time, Range:1~255) → Set Weekday (0:disable, 1: enable) → Succeeded  5 9Access programming mode →     Parameters[1] →     OnOff OpenZone → Main Controller Auto Open Zone (0:disable, 1:enable) → Open Door Imm. During Open Zone (0:No, 1:Yes) → WG1 Port Auto Open Zone (0:disable, 1:enable) → Open Door Imm. During Open Zone (0:No, 1:Yes) → Succeeded  3 2N. Lift control[e.g.] Connect with AR-401RO16B to control which oor the user will be able to access. (BAUD9600)Access programming mode →     Tools →     Terminal Port → 0:Lift Controller → Baud Selection 0: 96005 4Setting Lift controlAccess programming mode →     User Setting →     Single Floor →Input 5-digit user address → Input single oor number: 1~642 4Single oorAccess programming mode →     User Setting →     Multi Floor → Input 5-digit user address → Select range: 1 or 2 or 3 or 4 → Input 16 digits multi oors number [0:disable, 1: enable][e.g.] Set NO. 114, can use it through the 8 F and 16F:       Access programming mode →     User Setting →     Multi Floor → 114      → 1      → 0000000100000001           2255Multi oorsSet Floor/ Stop1017033049090250410570123430190350510110270430590201803405001002604205804020036052012028044060050210370530130290450610602203805401403004606207023039055015031047063081240400560161320480640Access programming mode →     Tools →     Terminal Port → 1:Lift Controller(need to use 725L485)5 5Access programming mode →     Tools →     Open TimeZone → Set (00~15) → Time (24 Hours) ; Main Port (0:disable, 1: enable) ; WG Port (0:disable, 1: enable) → Weekday (0:disable, 1: enable) → succeeded  5 6While connecting with AR-721U, AR-737H/U(WG mode) and AR-661U for anti-pass-back function, the access mode must be "Card" only.M. Anti-pass-backDevice enableAccess programming mode →     Parameters[2] →     Anti-pass-back → master controller select [1: Yes] → WG select [1: Yes]4 6Card user enableAccess programming mode →     Add/ Delete →     Antipass Group → Input 5-digit starting user address → Input 5-digit ending user address → must select [1: Yes]1 9
SOYALACCESS CONTROL SYSTEM®AR-837V140217         RESETRestoring Factory SettingsFirmware UpgradeReset all device parameters and user card dataReset IP Setting:When the device's power is on, press the【RESET】button on the main board untill the ERR (Red) LED of screen lights up. (Refere to the picture beside)※ After operation as above, you will hear a long reminder sound,and wait until the sound disappears, and then reset the power of the controller. The device will be restored to factory settings.Manu Tree5. Tools1. Language2. Master Code3. Master Range4. Terminal Port5. Ext.Comm Port6. Open Time Zone7. Informations8. Clock Setting9. Daily Alarm6. Quit7. Quit & Arming4. Parameters[2]1. Auto Relock2. Egress(R.T.E)3. Miscellaneous4. Force Open5. Close & Stop6. Anti-pass-back7. Duress Code8. Password Mode9. Factory Reset3. Parameters[1]1. Node ID2. OnOff OpenZone3. Door Relay Tm4. Door Close Tm5. Alarm Relay Tm6. Alarm Delay Tm7. Arming Delay Tm8. Arming PWD2. User Setting1. Password2. Access Mode3. Extend Options4. Single Floor5. Multi Floor6. Enroll Finger7. Delete Finger1. Add/ Delete1. Add > Card ID2. Add > RF Learn3. Suspend > Address4. Suspend > ID #5. Delete > Address6. Delete > ID #7. Recover > Address8. Recover > ID #9. Antipass GroupReset all device parameters and user card data:Access programming mode →     Parameters2 →     Factory Reset →0 : System Param ; 1 : User Setting ; 2 : System & User 945Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” softwareUpdate the rmware [Please login the SOYAL website to download the new ISP 1. Input the Target Address and Port2. [Load F/W] open the documents that have the new ISP Firmware3. Click the new ISP Firmware and [Open] it4. Click [Update F/W] to start the rmware update5. Till the screen shown [Firmware Update is Complete]Execute the software The software is within SOYAL CD or please login the SOYAL website to download12543※ After having done the "Factory Reset," the External Communication Port must be reset. Or the biometric sensor won't be functional.Tools →      Ext. Comm Port (0:FP-200 ; 1:Lift ; 2:Vein2000 ; 3:FP-9000 ; 4:Reserved )5
V140217admin                   Current StatusNetwork SettingUser PasswordLCD / Biometrics Access Controller IP SettingLog-in User PasswordWhen you choose the "Networking Setting" or "User Password" at rst.Log-in window will pop out and please input as below※ At the Factory Default StatusUser name: adminPassword: None by default, so please just click “OK” to log-inOpen your Web Browser and input factory default IP address: http://192.168.1.127Networking Setting You will nd initial IP Address 192.168.1.127 and check MAC Address is identical to the sticker on Ethernet Module device.  Please alter the IP address as you want, and then click “Update” button.  After updating the IP, please re-connect the Web Browser by the new IP address.User PasswordThe password is composed of 10 characters at most which can be either A~Z or 0~9.Change the log-in password to lock the IP setting of Ethernet Module.If the IP address of AR-837 (E/EF) has be changed, we must enter the new IP address.Show which computer is linking on Ethernet Module.Current IP address of the AR-837 (E/F) Page menuCurrent StateOnline Status is able to monitor and show which computer is linking on Ethernet ModuleIP SettingMonitor the on-line computerChange the Log-in information
NOTICE : The changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.The equipment has been tested and found to comply with the limits for a ClassB Digital Device, pursuant to part 15 of the FCC Rules.  These limits are designedto provide reasonable protection against harmful interference in a residentialinstallation.  This equipment generates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance with the instruction, may causeharmful interference to radio communication.  However, there is no grantee thatinterference will not occur in a particular installation.  If this equipment dose causeharmful interference to radio or television reception, which can be determined by turning the equipment off and on , the user is encouraged to try to correct the interference by one or more of the following measures:--Reorient or relocate the receiving antenna.--Increase the separation between the equipment and receiver.--Connect the equipment into an outlet on a circuit different from that to which the   receiver is connected.--Consult the dealer or an experienced radio/TV technician for help.