SOLiD HMAWS1M Alliance_5W User Manual MB DAS

SOLiD, Inc. Alliance_5W MB DAS

Contents

Alliance 5W Users manual_Rev.1_170726

 Confidential & Proprietary                    1/39 HERCULES (Alliance 5W Remote Unit) User Manual           SOLiD, Inc.  10,9th Floor, SOLiD Space220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 393-400  Tel : +82-31-627-6290    Fax : +82-31-627-6209
 Confidential & Proprietary                    2/39 REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 September. 07, 2014    Original   V1.1 June 29, 2017    Update Change the model name from   AWS-1_M to AWS13_M (Updated RDU CPU Firmware)                                                                                                  Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.kr or send email at   kehan@solid.co.kr  This manual is produced by Global Business Division Business Team 1. Printed in Korea.
 Confidential & Proprietary                    3/39 Contents Section1 Safety & Certification Notice ....................................................................... 5 Section2 Introduction ............................................................................................... 9 2.1 Purpose ......................................................................................................... 10 2.2 HERCULES ...................................................................................................... 11 Section3 Functional Description .............................................................................. 12 3.1 General ......................................................................................................... 13 3.2 Component of HERCULES Remote Unit ............................................................. 14 3.3 Dimension ..................................................................................................... 16 Section4 System Installation ................................................................................... 17 4.1 Remote Unit Installation ................................................................................. 19 4.1.1 Remote Unit Enclosure installation .................................................................. 19 4.1.2 How to expand ADD ON ROU at the Remote Unit .............................................. 23 4.1.3 Remote Unit Power Cabling ............................................................................. 25 4.1.4 Remote Unit Ground cabling ........................................................................... 26 4.1.5 Optical Cabling ............................................................................................... 28 4.1.6 Mounting of MRDU ........................................................................................ 30 Section5 System Specifications ................................................................................ 35 5.1 Physical Specifications .................................................................................... 36 5.2 RF performance .............................................................................................. 37 5.3 Certification ................................................................................................... 38
 Confidential & Proprietary                    4/39 Contents of Figure Figure 3.1 – Remote Unit Block Diagram ............................................................ 13 Figure 3.2 – Inside of Remote Unit .................................................................... 14 Figure 3.3 – Remote Unit Dimension ................................................................. 16 Figure 4.1 – Exterior of Remote Unit .................................................................. 19 Figure 4.2 – Dimension used to install REMOTE UNIT on the WALL ........................ 20 Figure 4.3 – Procedures of installation ............................................................... 21 Figure 4.5 – Connection diagram between Remote Unit and ADD ON ROU (DC type) .............................................................................................................. 24 Figure 4.6 – Location of Ground Terminal ........................................................... 26 Figure 4.7 – Information of Terminal .................................................................. 26 Figure 4.8 – How to install Ground Terminal ....................................................... 27 Figure 4.9 – Location of Optical Connector ......................................................... 28 Figure 4.10 – Information of Optical Connector .................................................. 28 Figure 4.11 – How to install Optical Cabling ........................................................ 29 Figure 4.12 – Location of MRDU ........................................................................ 30 Figure 4.13 – How to mount MRDU ................................................................... 31 Figure 4.14 – How to mount FAN Unit ................................................................ 32 Figure 4.15 – How to mount FAN Unit ................................................................ 33
 Confidential & Proprietary                    5/39 Section1                                 Safety & Certification Notice
 Confidential & Proprietary                    6/39 “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.”    - Obey all general and regional safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.  - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.  - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm.  - When working with units outdoors, make sure to securely fasten the door or cover in an open position to prevent the door from slamming shut in windy conditions.  - Use this unit only for the purpose specified by the manufacturer. Do not modify or fit any spare parts that are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.  - Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 310cm minimum clearance from the antenna while the system is operating.  - Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation.  - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors.  - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure.  - Allow sufficient fiber length to permit routing without severe bends.  - For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible.  - Certification    FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24 and 90  UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment  FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040
 Confidential & Proprietary                    7/39 - A readyily accessible disconnect device shall be incorporated external to the equipment.    - This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device  - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote.    Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system.    All components connected to this device must operate in the frequency range of this device.  - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device.  - The head end unit must always be connected to the Base Station using a direct cabled connection.    This system has not been approved for use with a wireless connection via server antenna to the base station.  - Round terminals located on the side of a 1 mm2 (16 AWG) or more wires Using permanently connected to earth.(green/yellow color)  - The following notice: "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device."  - Antenna installation Antennas must be installed in accordance with FCC 27.50, 24, and SRSP 518, SRSP 516, SRSP 510 and SRSP 517.   With 17dBi gain antennas the height of the antenna above average terrain (HAAT) must not exceed 375m.   For different gain antennas refer to the relevant rules.  - Prior to equipment use the service must be registered with the FCC.   This can be done through the FCC’s website at https://signalboosters.fcc.gov/signal-boosters/.  - Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and
 Confidential & Proprietary                    8/39 - Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location.  - Maximum antenna gain for downlink antenna after accounting for any cable losses should be less than 2 dBi.  - Notice! Be careful not to touch the Heat-sink part due to high temperature.  - Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited. -  - Home/ personal use are prohibited.     - Signal booster warning label message    WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device.    CAUTION DOUBLE POLE/NEUTRAL FUSING
 Confidential & Proprietary                    9/39  Section2                                          Introduction            2.1 Purpose 2.2 HERCULES
 Confidential & Proprietary                   10/39 2.1 Purpose HERCULES is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities.  Shopping malls  Hotels  Campus areas  Airports  Clinics  Subways  Multi-use stadiums, convention centers, etc.  The system helps improve in-building radio environments in poor condition and make better poor RSSI and Ec/Io. By providing communication services at every corner of buildings, the system enables users to make a call at any site of buildings.   The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods. The HERCULES system supports communication standards and public interface protocols in worldwide use.  Frequencies: 700MHz , 700MHz_MIMO , 850MHz , 1900MHz , 2100MHz , 2100MHz_MIMO etc.    Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc.  Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging, LTE etc.  HERCULES is in modular structure per frequency. To provide desired frequency in a building, all you need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals with one optical cable, the system, in one-body type, does not require additional facilities whenever new frequency is added. The system is featured with the following:  Flexibility & Scalability  Support fiber-optic ports up to 60  Clustering multiple-buildings (campus) as one coverage   Modular structures  Modular frequency upgrade  Plug-in type module    Multi-Band, Multi Operator
 Confidential & Proprietary                   11/39  Signals with a plurality of service provider transmit simultaneously      Support multi-operator in a band    Low OPEX / CAPEX  Compact design    Upgradable design    Easy installation and maintenance  2.2 HERCULES Hercules is one of series of Alliance DAS and has 5W composite output power every band. RDU that is integrated on package with Duplexer, Power amplifier and RF unit can be mounted up to 6 in the enclosure. Hercules transports signals that multiple operators and multiple technologies are moved at a same time from Base station to a remote location over the same fiber. It is available in single and multi-band configuration supporting 700M, 700M MIMO , 850M , 800I , 900I , 700P , 800P , 1700/2100M, 1700/2100MHz MIMO , 1900M in parallel. It has been specifically tested under a various air interfaces such as iDEN, GSM, CDMA2000, EV-DO, WCDMA, LTE , ect. Furthermore, there is reserved RDU slot to support 2500LTE in the future And RDU slot is also possible to replace the desired frequency Band.
 Confidential & Proprietary                   12/39 Section3                               Functional Description            3.1 General   3.2 Compoent of HERCULES Remote Unit 3.3 Dimension
 Confidential & Proprietary                   13/39 3.1 General The following figure shows the block diagram of HERCULES Remote Unit.    Figure 3.1 – Remote Unit Block Diagram  There are many components;  R-Optic : Remote Optical Unit  RCPU : Remote Central Processor Unit  RPSU(AC) :  Remote AC Power Supply Unit(When using the AC input power)  RPSU(DC) :  Remote DC Power Supply Unit(When using the DC input power)  RDU1-6 : Remote Drive Unit  CU1 : Combining Unit  CU2 : Combining Unit
 Confidential & Proprietary                   14/39 3.2 Component of HERCULES Remote Unit The following figure shows internal configuration of Remoe Unit with fully RF equipped.   Figure 3.2 – Inside of Remote Unit Remote Unit receives TX optical signals from Head-End and converts them into RF signals. The converted RF signals are amplified through High Power Amp in a corresponding RDU, combined with Multiplexer module and then radiated to the antenna port. When receiving RX signals through the antenna port, this unit filters out-of-band signals in a corresponding RDU and sends the results to Remote Optic Module to make electronic-optical conversion of them. After converted, the signals are sent to a upper device of ODU. ROU can be equipped with up to six RDUs (Remote Drive Unit)
 Confidential & Proprietary                   15/39 The following table describes components on Remote Unit Unit Description RDU+BPF x6 Remote Drive Unit Filter and amplify TX signals Filter and amplify RX signals Remove other signals through BPF RPSU(AC) Remote AC Power Supply Unit Input power: 120 VAC +/- 10% Output power: +29 VDC RPSU(DC) Remote DC Power Supply Unit Input power: -48 VDC +/- 10% Output power: +29 VDC R-OPTIC Remote Optic Make RF conversion of TX optical signals; Convert RX RF signals into optical signals; Compensates optical loss Communicates with BIU/OEU though the FSK modem 5dBo optical link between ODU(OM4) and ROU   10dBo optical link between ODU(OM1) and ROU  Fiber Connector: SC/APC Connector Fiber Type: Single Mode Fiber Optical Wavelength: 1310/1550 WDM RCPU Remote Central Processor Unit Controls signal of each unit Monitors BIU/ODU/OEU through FSK communication CU1(Multiplexer) CU1 Combine TX signals from 5 RDUs; Distribute RX signals to 5 RDUs Furthermore, there is reserved RDU slot to support 2600LTE  Enable you to use a single antenna port CU2(Multiplexer) CU2 Combine TX signals from 2 RDUs; Distribute RX signals to 2 RDUs Enable you to use a single antenna port ROU Enclosure Enclosure to satisfy IP66 Vertical Mount Wall Mount Input SIU Input System Interface Unit Distributes power and signals to each module Output SIU Output System Interface Unit Interfacing with multiplexer
 Confidential & Proprietary                   16/39 3.3 Dimension  Figure 3.3 – Remote Unit Dimension  ITEM SPECIFICATION REMARK Size(Width, Height, Depth) 320 x 1165 x 260mm Including Bracket Weight 62kg / 137lb Fully loaded Power Consumption 510W Fully loaded Operating Temperature -25 to +55°C / -13 to 131°F Ambient Temperature Operating Humidity 0 to 90%, non-condensing
 Confidential & Proprietary                   17/39 Section4                          System Installation            5.1 Remote Unit Installation This chapter describes how to install each unit and optical cables, along with power cabling method. In detail, the chapter describes how to install shelves or enclosures of each unit, Power Cabling method and Optic Cabling and RF Interface.   The needed accessories and tools are list up in the below table.  Steps for installation Accessories Included Tool Remark Remote Enclosure Installation M12 Bolt (4EA)  X  Spanner(19mm)  - Power Connection_AC AC 120V power cable (1EA) [2 meter, with MIL-5015 type Connector (MS-3106A- 18-10S) at one end, AC Plug at another end] ○ -  - Power Connection_DC DC -48V power cable (1EA) [2 meter, with MIL-5015 type Connector (MS-3106A- 18-10S) at one end, 4.5 ø square lugs at another end] ○ -  - Optical Connection Optical Cable Assembly Connector (1EA) [SOLI-FIBER-ASS’Y, by LTW]   ○ - For more details,
 Confidential & Proprietary                   18/39 OPTIC SC/APC Cable (1EA)  X - refer to 4.1.5 Ground Connection M6 Screw (1EA) ○ No.2 Screw driver (+) For more details, refer to 4.1.4 Lug (1EA) ○ Crimping Tool Max. AWG #6 Cable  X Antennal Connection RF Cable (1 or 2EA)  X  Spanner (33mm)   2 EA is required in  case of MIMO. MRDU Installation -  -  No.1 Screw driver (+) For more details, refer to 4.1.6 Connection with ADD ON ROU AC power cable (1 EA) [1.5 meter, with MIL-5015 type Connector (MS-3106A-16-10S) and Circular Connector  (C016_20H003_100_12, by LTW)]   ○ -  - Data Interface cable (1 EA) [1.5 meter, with MIL-5015 type Connector (MS-3106A-14S-5S) at both ends]   ○ -  - RF interface cable (2EA) [1.5 meter, with N male connector at both ends]  ○ -  - FAN Unit (Option) Inner Fan Cable ○ Spanner (10mm)- For more details, refer to 4.1.7 Fan Unit ○ - M6 Screw (1EA)  X  No.2 Screw driver (+)
 Confidential & Proprietary                   19/39 4.1 Remote Unit Installation 4.1.1 Remote Unit Enclosure installation Remote Unit is designed to be water- and dirt-proof. The unit has the structure of one-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4(IP66).  Basically  Remote Unit is attached with wall mountable bracket. Remote Unit can be mounted into either of wall or on a pole.    Figure 4.1 – Exterior of Remote Unit
 Confidential & Proprietary                   20/39  Figure 4.2 – Dimension used to install REMOTE UNIT on the WALL
 Confidential & Proprietary                   21/39 Remote Unit Wall Mount Installation  Remote Unit’s installation bracket is attached on Enclosure when is delivered. It doesn’t need to remove bracket to install enclosure. simply after installing 4 of M12 mounting bolts, secure 4 mounting bolts tightly First, install 2 of M12 mounting bolts roughly half way on the enclosure and install enclosure over the bolts and secure tightly. Second, install 2 of M12 mounting bolts under the enclosure and secure tightly.  Figure 4.3 – Procedures of installation
 Confidential & Proprietary                   22/39 Remote Unit Components Remote Unit has the following components: No. Unit Description Remark Common Part Enclosure Including Wall mounting bracket 1EA RCPU  -  1EA R_OPTIC With SC/ACP adaptor(only Remote Unit) 1EA,optional RPSU AC 120V or DC-48V 1EA Power Cable MS Connector with 4 hole 1EA MRDU MRDU-850CEL MRDU-1900PCS MRDU-700LTE MRDU-2100AWS13 MRDU-2500LTE(Reserved) ANT1 MRDU MRDU-700LTE_MIMO MRDU-2100AWS-1_MIMO ANT2 CU1 Internal Combiner unit for 700, 900,850, 1900, 2100, and 2500(Reserved) ANT1 CU2 or CU3 Internal Combiner unit for 700 and 2100 MIMO Internal Combiner unit for 700P/800P and 900I ANT2  Basically, the common part of Remote Unit should have an enclosure and it is equipped with RCPU to inquire and control state of each module, R_OPTIC to make both of electronic-optical and optical-electronic conversions, RPSU to supply power for Remote Unit. It should have Power Cable for external rectifier or to supply required power. In addition, MRDU can be mounted and removed to provide service for desired band.
 Confidential & Proprietary                   23/39  4.1.2 How to expand ADD ON ROU at the Remote Unit         Remote Unit can expand ARU up to 1. The three item is needed for connection between Remote Unit and ADD ON ROU. ADD ON ROU’s components additively have 3 item except for enclosure like below Accessories Description Qty Specification Remark 1  TX RF Cable  1 N(M) ST to SMA(M) ST_1.5M  2  RX RF Cable  1 N(M) ST to SMA(M) ST_1.5M  3  I/O Cable  1 IEC 61076-2-101(8pin_F) ST_1.5m  4 Power Cable (AC type only) 1 MIL-5015(16-10_F) ST to Circular(eco mate 3+PE_M) ST_1.5m       The following picture shows the connection diagram between Remote Unit and ADD ON ROUs
 Confidential & Proprietary                   24/39 For expanding ADD ON ROU at the Remote Unit within the proper cable length provided. The cables between Remote Unit and ADD ON ROU have each 1.5m length.    Figure 4.4 – Connection diagram between Remote Unit and ADD ON ROU (AC type)  Figure 4.5 – Connection diagram between Remote Unit and ADD ON ROU (DC type)
 Confidential & Proprietary                   25/39 4.1.3 Remote Unit Power Cabling   AC Power Remote Unit supports only AC120V of input power. Provided outside power cable is only one type. The pin discription of AC port is below. You should connect exact polarity of AC.  Port outlook MS Connector numbering  Name  Description  A  AC_H AC Hot B  AC_N AC Neutral C  N.C Not Connected D  F.G  Frame Ground Check if the connection is the same as one seen in the table above and make sure to turn the power ON. Provided AC power cable’s outlook is below  DC Power Remote Unit supports only DC48V of input power. Provided outside power cable is only one type. The pin discription of DC port is below. You should connect exact polarity of DC.  Port outlook MS Connector numbering  Name  Description  A  N.C Not Connected B  N.C Not Connected C  +V +48V D  -V  -48V Check if the connection is the same as one seen in the table above and make sure to turn the power ON. Provided DC power cable’s outlook is below
 Confidential & Proprietary                   26/39 4.1.4 Remote Unit Ground cabling The  Grounding terminal is located at the bottom of Remote Unit enclosure fixed by M6 screw. Compression terminal is attached already when is delivered. The recommended thickness of cable is AWG#6 copper grounding wire   Figure 4.6 – Location of Ground Terminal  The specification of compression terminal is like below  Figure 4.7 – Information of Terminal
 Confidential & Proprietary                   27/39 The required part number is JOCT 16-6 supporting AWG 6. The way to install the grounding cable comply with below procedures     Figure 4.8 – How to install Ground Terminal  The procedures are   1. Loosen a two M6 screws and then take compression terminal off   2. Insert AWG#6 Grounding Wire into terminal and then compress a terminal using tool 3. Assemble the terminal which made in step “2” using 2xM6 screws 4. Cut the ground wire to proper length and connect it to the earth ground source
 Confidential & Proprietary                   28/39 4.1.5 Optical Cabling The  Optical Connector is located at the bottom of Remote Unit enclosure fixed.  Optical Cable can be connected by using connectors.   Figure 4.9 – Location of Optical Connector  The specification of compression Optic Connector is like below   Figure 4.10 – Information of Optical Connector
 Confidential & Proprietary                   29/39 The way to install the Optical cable comply with below procedures The procedures are             Figure 4.11 – How to install Optical Cabling
 Confidential & Proprietary                   30/39 4.1.6 Mounting of MRDU Remote Unit has slots to enable up to six MRDU modules to be mounted in it. You can mount a MRDU into designated slot surely. It is not possible to provide services with a MRDU module alone; you need to connect MRDU cavity duplexer antenna port with CU’s designated port.  Installation Diagram for MROU Module Assembly 1) Install each MRDU into its designated location as shown in the graphic.   2) If MRDUs are inserted in slot #5 or #6, install the optional combiner unit (CU) according to these guidelines: Option 1: CU_70B21B     Use this unit for combining MRDU_700LTEF_B / MRDU_AWS_B Option 2 : CU_708090       Use this unit to combine MRDU_700PS_800PS / MRDU_900i  Figure 4.12 Location of MRDU
 Confidential & Proprietary                   31/39  The Remote Unit holds a maximum of 6 MRDUs. Guide brackets on the bottom of each MRDU slot simplify installation as described below. MRDU installation requires a +No.1 tip size screwdriver.      Figure 4.13 – How to mount MRDU
 Confidential & Proprietary                   32/39  The procedures are   1. Lift the MRDU onto the guide bracket and ensure the MRDU is level left to right 2. Push the MRDU into the corresponding slot in the direction of the heat sink while levelling the MRDU to guide bracket 3. Make sure the MRDU is firmly inserted into the corresponding slot. Tighten the 4 corner screws to secure the unit 4. Install MRDU blank cards in all unused slots in the remote. First insert the blank card into the corresponding slot, then tighten the captive screw to secure it  4.1.7 How to mount FAN Unit FAN unit is required to be installed on the bottom of the 5W remote as shown in the below figure. In the case that MROU temperature on GUI exceeds 70℃ (1580F), the fan unit is required to be installed on the bottom of the remote unit.   Figure 4.14 – How to mount FAN Unit
 Confidential & Proprietary                   33/39    Figure 4.15 – How to mount FAN Unit
 Confidential & Proprietary                   34/39  The procedures are   1. Remove dummy bolt attached at FAN Port 2. Connect internal FAN cable to the FAN Port, and connect with the connector located on the top of PSU. 3. Install fan unit to the bottom of 5W remote with aligning heatsink pin to the guided groove. 4. Secure the fan unit by tightening M6 screw located on the left corner. 5. After securing the FAN Unit, connect the cable from FAN unit to FAN port.
 Confidential & Proprietary                   35/39 Section5                                       System Specifications            6.1 Physical Specifications 6.2 RF Performance 6.3 Certification
 Confidential & Proprietary                   36/39 5.1 Physical Specifications  Parameter ROU Nominal Impedance(input and output)    50 ohm    RF Connectors DIN Female (7/16)    Mounting Type      Wall Mounting    Serial Interface connector (1) RS-232 9-pin D-sub, male Fiber connector (1) SC/APC for ODU LED Alarm and Status Indicator Power LED TX LED RX LED LD LED PD LED ALARM LED RESET Button AC Power 108~132V AC, 50/60Hz DC Power -40.8 ~ -57.6V DC Environmental Condition & IP Rating    IP66  Maximum Power Consumption    510W at full load             Enclosure Dimensions (mm) 320 x 1165 x 260mm Weight (Full Load) 62kg Optical Data    Wavelength TX/RX    1310/1550nm    Maximum Optical Loss    10dBo    Fiber Optic Connector    SC/APC
 Confidential & Proprietary                   37/39 5.2 RF performance MRDU Specifications Per band Downlink Unit naming Description Gain(dB) Bandwidth(MHz) output power(dBm)  Frequency range MRDU 850C Single, 49 25  +39  869 - 894MHz MRDU 850IC Dual, 49 49 7 25 +37 +37 862 - 869MHz 869 - 894MHz MRDU 1900P Single, 53 65  +37  1930 - 1995MHz MRDU 700LTE Single, 49 28  +37  728 - 756MHz MRDU AWS13 Single,  54.2 70  +38.2 2110 - 2180MHz MRDU 700LTE_MIMO Single, 53 28  +37  728 - 756MHz MRDU_AWS13_M Single, 53 70  +37  2110 - 2180MHz MRDU 900I Single, 49 12  +37  929 - 941MHz MRDU 700P+800 Dual, 49 49 17 10 +37 +37 758 - 775MHz 851 - 861MHz MRDU 2300_WCS Single 53 10 +37 2350 – 2360MHz MRDU 2.5TDD Single 53 193.2  +37 2496.8 - 2690MHz (FCC) 2500 – 2690MHz (IC) MRDU 2600_FDD Single 53 70 +37 2620 – 2690MHz MRDU_1900P_M Single, 53 65 +37 1930 - 1995MHz MRDU_2500_60TDD_M Single 53 193.2 +37 2496.8 - 2690MHz (FCC) 2500 – 2690MHz (IC) MRDU_700LTE_FN Single, 49 40  +37 728 - 768MHz  Uplink Unit naming Description Gain(dB) Bandwidth(MHz) output power(dBm) Frequency range MRDU 850C Single, 47 25  -5  824 - 849MHz MRDU 850IC Dual, 47 47 7 25 -5 -5 817 - 824MHz 824 - 849MHz MRDU 1900P Single, 47 65  -5  1850 - 1915MHz
 Confidential & Proprietary                   38/39 MRDU 700LTE Single, 47 47 17 10 -5 -5 699 - 716MHz 777 – 787MHz MRDU AWS13 Single, 47 70  -5  1710 – 1780MHz MRDU 700LTE_MIMO Single, 47 47 17 10 -5 -5 699 - 716MHz 777 – 787MHz MRDU_AWS13_M Single, 47 70  -5  1710 – 1780MHz MRDU 900I Single,  47  6  -5  896 - 902MHz MRDU 700P+800 Dual, 47 47 17 10 -5 -5 788 - 805MHz 806 - 816MHz MRDU 2300_WCS Single 47 10  -5  2305 – 2315MHz MRDU 2.5TDD Single 47 189.6  -5 2496.8 - 2690MHz (FCC) 2500 – 2690MHz (IC) MRDU 2600_FDD Single 47 70  -5  2500 – 2570MHz MRDU_1900P_M Single, 47 65  -5  1850 - 1915MHz MRDU_2500_60TDD_M Single 47 193.2  -5 2496.8 - 2690MHz (FCC) 2500 – 2690MHz (IC) MRDU_700LTE_FN Single, 47 40  -5 699 - 716MHz 777 – 798MHz  5.3 Certification Title   Standards  Remarks  Environmental Temperature range -25°C to +55°C/ -13 to 131°F Ambient Temperature Humidity Range 0% ~ 90% Non-condensing Sealing (Remote Unit) IEC 60 529 EN 60 529 IP66 Complaint  RSS-GEN, Sec. 7.1.2 – (transmitters)  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie
 Confidential & Proprietary                   39/39 Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante.  RSS-GEN, Sec. 7.1.2 – (detachable antennas)  This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.  Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.  RF Radiation Exposure   This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 310 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.  RSS-102 RF Exposure L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 310 cm entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur.

Navigation menu