SOLiD 850C700LTEC RDU MODULE(850C/700LTEC) User Manual

SOLiD, Inc. RDU MODULE(850C/700LTEC)

User manual-3

 Confidential & Proprietary                   81/139  Figure 5.6 – Dimension used to install ROU on the WALL   ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure.   Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
 Confidential & Proprietary                   82/139   Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove.   ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection.
 Confidential & Proprietary                   83/139   ROU component ROU has the following components: No.  Unit  Description  Remark Enclosure  Including Rack & Wall cradle  1EA RCPU -  1EA R_OPTIC  With SC/ACP adaptor 1EA RPSU  Alternative DC-48V or AC 120V    1EA Multi-Plexer -  1EA Common Part Power Cable  - MS Connector with 3 hole to AC 120 plug(AC) - MS Connector with 2 lug termination(DC)   Optional Part  RDU+BPF 800PS,800PS+900I+Paging,850C,850C+700PS, 1900P+ AWS-1 RDU, VHF+UHF(NO BPF),850C+700LTEC Up to 3EA to be inserted  Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to inquire and control state of each module, R_OPTIC to make both of electronic-optical and optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or to supply required power.
 Confidential & Proprietary                   84/139 In addition, RDU can be inserted and removed to provide service for desired band (Optional).  5.3.2  ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while each of the units uses different input voltage from each other.  The following figure shows configuration of RPSUs for DC -48V and AC 120V.
 Confidential & Proprietary                   85/139  Lug Naming  RPSU Terminal naming MC Connector numbering  AC  DC  AC  DC Remark A AC_H -48V AC-H  -48V   B AC_N GND AC-N  IN_GND   C GND DC NC FG  FG    Check if the connection is the same as one seen in the table above and make sure to turn the power ON.  5.3.3 Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic- optical conversion of RX signals. ROU has one optical module in it. As WDM is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type. For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.
 Confidential & Proprietary                   86/139 Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in ROU, you need to coil around one or two roll of cables to be connected with the optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm).  5.3.4  GND Terminal Connection ROU has one GND terminal port where is on bottom side, like below    -  Take off the GND terminal port from enclosure and connect to ground cable, then fix it the position of enclosure again -  The opposite end of the ground cable should connect to the communication GND of building  -  The ground lug is designed meeting the SQ5.5 standard  5.3.5  Coaxial cable and Antenna Connection -  The coaxial cables which are connected to antenna distribued network connect to antenna port of ROU. Before connection, check the VSWR value of coaxial cable whether it is within specification using SITEMASTER . -  At this time, check if the Return loss have above 15Db or VSWR have below 1.5 -  The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and insects - The antenna connected to ROU is only serviced in inbuilding          5.3.6  Insertion of RDU ROU has slots to enable up to three RDU modules to be inserted into the unit.
 Confidential & Proprietary                   87/139 You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case. The table below shows types of RDU and CAVITY BPF: Multiplexer Interface No  Unit naming  Cavity BPF  RF CABLE  TX  RX 1  RDU 800PS  800PS BPF  TX CABLE 1EA RX CABLE 1EA  BPF OUT  RDM RX IN 2  RDU 850C  850C BPF  TX CABLE 1EA RX CABLE 1EA BPF TX OUT  BPF RX IN 3  RDU 1900P+AWS-1  1900P DUP  TX/RX CABLE 1EA  RDM AWS+1900P 5  RDU 800PS+900I+PA 800PS+900I+PA BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT  RDM RX IN 6  RDU 850C+700PS 850C+700PS BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT  RDM RX IN 7  RDU VHF+UHF  -  TX CABLE 1EA RX CABLE 1EA  - - 8  RDU 850C+700LTEC850C+700LTEC BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT  RDM RX IN The following describes how to install RDU in ROU.  How to install RDU 800PS Ass’y The following components are required: No.  Unit  Description  Remark 1  RDU 800PS  RF Module   2 800PS BPF  BPF   3  800PS TX RF CABLE  SMA(M) to SMA(M), 360mm   4  800PS RX RF CABLE  SMA(M) to SMA(M), 410mm
 Confidential & Proprietary                   88/139  ① Combine RDU 800PS with 800PS BPF (As it is a plug type, push the unit to combine with BPF.) ②  Insert the combined 800PS+850C BPF Ass’y into any slot of ROU. ③  Combination point of 800PS+800PS BPF Ass’y of the multiplexer  Interface Point Multiplexer Port naming  800PS RDU  800PS BPF  Remark 800PS+900I+PA TX  -  TX OUT   800PS+900I+PA RX  RX IN  -
 Confidential & Proprietary                   89/139 How to RDU install 850C Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 850C  RF Module   2 850C BPF  BPF   3  850C TX RF CABLE  SMA(M) to SMA(M), 310mm   4  850C RX RF CABLE  SMA(M) to SMA(M), 310mm    ①  Combine 850C RDU with 850C BPF (As it is a plug type, push the unit to combine with BPF.) ②  Insert the combined 850C+850C BPF Ass’y into any slot of ROU. ③  Combination point of 850C+850C BPF Ass’y of the multiplexer   Interface Point Multiplexer Port naming  850C RDU  850C BPF  Remark 850C TX  -  TX OUT   850C RX  -  RX IN
 Confidential & Proprietary                   90/139  How to install RDU 800PS+900I+PA Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 800PS+900I+PA  RF Module   2 800PS+900I+PA BPF  BPF   3  800PS+900I+PA TX RF CABLE  SMA(M) to SMA(M), 460mm   4  800PS+900I+PA RX RF CABLE  SMA(M) to SMA(M), 380mm    ① Combine RDU 800PS+900I+PA with 800PS+900I+PA BPF (As it is a plug type, push the unit to combine with BPF.) ②  Insert the combined 800PS+900I+PA BPF Ass’y into any slot of ROU. ③  Combination point of 800PS+900I+PA BPF Ass’y of the multiplexer Interface Point Multiplexer Port naming  800PS+900I+PA RDU  800PS+900I+PA BPF Remark
 Confidential & Proprietary                   91/139 800PS+900I+PA TX  TX OUT  -   800PS+900I+PA RX  RX IN  -    How to install RDU 850C+700PS Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 850C+700PS  RF Module   2 850C+700PS BPF  BPF   3  850C+700PS TX RF CABLE  SMA(M) to SMA(M), 470mm   4  850C+700PS RX RF CABLE  SMA(M) to SMA(M), 400mm    ① Combine RDU 850C+700PS with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.) ②  Insert the combined 850C+700PS BPF Ass’y into any slot of ROU. ③  Combination point of 850C+700PS BPF Ass’y of the multiplexer Interface Point Multiplexer Port naming  850C+700PS RDU 850C+700PS BPF  Remark 850C+700PS TX  TX OUT  -
 Confidential & Proprietary                   92/139 850C+700PS RX  RX IN  -    How to install RDU 1900P+AWS-1 Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 1900P+AWS-1  RF Module   2 1900P+AWS-1 BPF  BPF   3  1900P+AWS-1 RF CABLE  SMA(M) to SMA(M), 390mm   4  1900P+AWS-1 RF-01  SMA(M) to SMA(M)  Semirigid  ① Combine RDU 1900P+AWS-1 with 1900P BPF (As it is a plug type, push the unit to combine with BPF.) ②  Connect BPF 1900P port with 1900P port of 1900P RDU through 1900P+AWS-1 RF-01 RF CABLE.  ③  Insert the combined 1900P+AWS-1 BPF Ass’y into any slot of ROU. ④  Combination point of 1900P+AWS-1 BPF Ass’y of the multiplexer  Multiplexer Port naming  Interface Point  Remark
 Confidential & Proprietary                   93/139  1900P+AWS-1 RDU  1900P BPF   AWS-1+1900P COM  1900P+AWS  -    How to install RDU VHF+UHF Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU VHF+UHF  RF Module   2  RDU VHF+UHF RF CABLE  SMA(M) to SMA(M), 460mm   3  RDU VHF+UHF RF CABLE  SMA(M) to SMA(M), 380mm    ①  Insert the combined VHF+UHF RDU    into any slot of ROU. ②  Connect RDU VHF+UHF Port    with ROU VHF+UHF Port through VHF+UHF RF CABLE How to install RDU 850C+700LTEC Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 850C+700LTEC  RF Module   2 850C+700PS BPF  BPF   3  850C+700PS TX RF CABLE  SMA(M) to SMA(M), 470mm
 Confidential & Proprietary                   94/139 4  850C+700PS RX RF CABLE  SMA(M) to SMA(M), 400mm    ① Combine RDU 850C+700 LTEC with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.) ②  Insert the combined 850C+700 LTEC BPF Ass’y into any slot of ROU. ③  Combination point of 850C+700PS/700LTE BPF Ass’y of the multiplexer Interface Point Multiplexer Port naming  850C+700LTEC RDU 850C+700PS BPF  Remark 850C+700PS TX  TX OUT  -   850C+700PS RX  RX IN  -
 Confidential & Proprietary                   95/139    You cannot insert the same module and band into MULTIPLEXER port at the same time. For example, you are not supposed to insert both of 800PS RDU and 800PS+900I+PA RDU into ROU at the same time. In the same way, you cannot concurrently insert both of 850C RDU , 850C+700PS RDU and 850C+700LTEC into ROU.   Information of LED at the front RDU  RDU has the structure of enabling a random RDU to be inserted into three slots.   ROU can be equipped with a total of three RDUs. If only one RDU is inserted into a slot
 Confidential & Proprietary                   96/139 and the other slots ramian reserved, you need to insert BLANK cards into the other slots. When RDU is inserted into ROU, LED of the front panel shows the following information:     LED  Description   Power is not supplied ON    Power is supplied.  Normal Operation ALM   Abnormal Operation
 Confidential & Proprietary                   97/139   Up to three RDUs can be inserted. If one or two units of them are used, then you need to terminate the unused slot of RDU with a BLANK card.   5.3.7  Consumption of RDU The following table shows power consumption of RDU: Part  Unit  Consumption Power  Remark Enclosure RCPU ROPTIC RPSU Common Part Multiplexer 17W  RDU 800PS  39W   800PS  49W  900I+PA HPA OFF 900I+PA 72W 800PS HPA OFF RDU 800PS+900I+Paging FULL  79W  Both HPA ON RDU 850C  39W   850C 49W 700PS HPA OFF RDU RDU 850C+700PS 700PS  58W  850C HPA OFF
 Confidential & Proprietary                   98/139  FULL  93W  Both HPA ON 1900P  46W  AWS-1 HPA OFF AWS-1  46W  1900P HPA OFF RDU 1900P+AWS-1 FULL  68W  Both HPA ON VHF  47W  VHF  HPA OFF UHF  47W  UHF  HPA OFF  RDU VHF+UHF FULL  74W  Both HPA ON For power consumption of ROU, the common part consumes 17W. Depending on the quantity of each RDU, you can add overall power consumption of ROU. Only, in case of Dual-Band signals, power consumption is calculated respectively when HPA of the other party is turned OFF and two HPA devices are turned ON. Note that when you calculate Power Budget.  5.4 OEU Installation OEU is used to expand ROU in Campus Site. OEU is located at a Remote Closet. As it can be equipped with up to two DOUs, you can expand a total of eight ROUs. 5.4.1  OEU Shelf installation OEU is a shelf in around 2U size. Its width is 19” and so this unit should be inserted into a 19” Standard Rack. OEU is in a Remote Closet, providing optical ports of ROU. The following table shows power consumption of OEU: No.  Unit  Description  Remark Shelf  Including EWDM,ERF,EPSU,ECPU,  19”,2U  1EA Common Part Power Cable  -48Vdc Input with two lug terminal    1EA Optional Part  DOU  Optical Module with 4 Optic Port  Up to 2EA to be inserted
 Confidential & Proprietary                   99/139 5.4.2  OEU Power Cabling The input power of OEU is DC -48V. You need to connect DC cable with the Terminal Block seen at the rear of OEU. Terminal  Color of cable  Description  Remark -48V  Blue color  Input range: -42 ~ -56Vdc   NC Not Connected     GND Black color     Before connecting the power terminal, you need to connect “+” terminal of Multi Voltage Meter probe with the GND terminal and then connect “–“ terminal with -48V to see if “-48Vdc” voltage is measured. After the check, connect the power terminal through the terminal seen below.
 Confidential & Proprietary                   100/139   Note that OEU does not operate if the “+” terminal and the “–“ terminal of the -48V power are not inserted into the accurate polarity.     5.4.3  OEU Optic Cabling OEU is connected with upper ODU. With DOU inserted in it, the unit is connected with ROU. As OEU has a shelf with EWDM in it, the unit makes electronic-optical conversion of TX signals from ODU and makes optical-electronic conversion of RX signals. In addition, OEU can be equipped with up to two DOUs. One DOU supports four optical ports and one optical port can be connected with ROU. With WDM in DOU, the unit can concurrently send/receive two pieces of wavelength (TX:1310nm, RX:1550nm) through one optical core. DOU has SC/APC of optical adaptor type.  Figure 5.7 – Optical cable of SC/ACP Type For optical adaptor, SC/APC type should be used. To prevent the optical access part from being
 Confidential & Proprietary                   101/139 marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.  5.4.4  Insert DOU to OEU Into OEU Shelf, up to two DOUs can be inserted. DOU module is in Plug in Play type. When you insert DOU in OEU, insert the unit into the top DOU1 slot first. You can be careful as the number is silk printed at the left.   The following figure shows installation diagram of OEU with one DOU inserted in it.  The following figure shows installation diagram of OEU with two DOUs inserted in it.      When you insert DOU into OEU, insert the unit into the top DOU1 first. For unused slots,
 Confidential & Proprietary                   102/139 you nedd to install BLANK UNIT into them.   5.4.5  Consumption Power of OEU   OEU has -48V DC Power supply in it. ODU can be equipped with up to two DOUs. Depending on the quantity of DOU, power consumption is varied.   The following table shows power consumption of OEU: Part  Unit  Consumption Power Remark Shelf EWDM ERF Common Part EPSU 12W  OEU_4  DOU 1 EA  23W   OEU_8  DOU 2 EA  33W    5.5  ADD ON V/UHF ROU Installation 5.5.1  AOR Enclosure installation AOR is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4 like existing ROU AOR can be mounted into either of a 19” Standard Rack or on a Wall.   Basically, AOR has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the usage the Rack Mount Bracket or the Wall bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket.
 Confidential & Proprietary                   103/139 AOR should be installed above or under of exisitng ROU  Figure 5.8 – How to install AOR  Figure 5.9 – Dimension used to install AOR on the WALL     ROU Wall Mount Installation  Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure. Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
 Confidential & Proprietary                   104/139   Figure 5.10 – Installation flow diagram when AOR installs on wall    Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 6EA of M5 Wrench Bolts in total except bolts used for the fixing groove.     ROU Rack Mount Installation  Like other units, AOR is designed to be inserted into a rack. The unit occupies about 4U of space except cable connection. In case that AOR is installed more close above/below existing ROU, temperature of ROU/AOR increase ambient temperature, which increase ambient of AOR/ROU. Then, AOR/ROU’s
 Confidential & Proprietary                   105/139 temperature is increased. Therefore, we recommend that AOR should be installed with at least constant space from existing ROU(above 2U) The following shows the installed diagram on rack with exisiting ROU   Figure 5.10 – Installation flow diagram when AOR installs in the rack     AOR components AOR has the following components: No.  Unit  Description  Remark Enclosure  Including Rack & Wall bracket  1EA AOR PSU  Alternative DC-48V or AC 120V    1EA Common Part V/UHF RDU  -  1EA