SOLiD 19PAWS1MIMO RDU Module (1900P/AWS-1 (MIMO)) User Manual MB DAS

SOLiD, Inc. RDU Module (1900P/AWS-1 (MIMO)) MB DAS

User Manul

 Confidential & Proprietary                                      1/28 SMDR-NH124(Remote Unit) User Manual       Document Reference:     Version:  V1.0 Document Status:  Release 1 Issue Date:  July. 16, 2014 Author:  Young Ju YOU Department:  R&D Division Team 3     Authorizing Manager:            Young shin Yeo
 Confidential & Proprietary                                      2/28 REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 July. 16, 2014  Original                                                              Technical Support SOLiD  serial  numbers must  be  available  to  authorize  technical  support  and/or  to  establish  a return authorization for defective units. The serial numbers are located on the back of the unit, as  well  as  on  the  box  in  which  they  were  delivered.  Additional  support  information  may  be obtained  by  accessing  the  SOLiD  Tehcnology, Inc.  website at www.st.co.kr  or  send  email  at sjkim@st.co.kr    This manual is produced by Global Business Division Business Team 1. Printed in Korea.
 Confidential & Proprietary                                      3/28 Contents Section1 Safety & Certification Notice ................................................................. 5 Section2 System Overview .................................................................................... 8 2.1 Purpose ......................................................................................................... 9 2.2 SMDR-NH124 .............................................................................................. 10 Section3 Functional Description ......................................................................... 11 3.1 General (Remote Optic Unit) ...................................................................... 12 3.2 Component of SMDR-NH124 Remote Unit ................................................ 13 3.3 Dimension ................................................................................................... 15 Section4 System Installation ............................................................................... 16 4.1 ROU Installation ......................................................................................... 16 4.1.1 ROU Enclosure installation ................................................................. 16 4.1.2 ROU Power Cabling ............................................................................. 20 4.1.3 Optical Cabling ..................................................................................... 21 4.1.4 GND Terminal Connection ................................................................... 22 4.1.5 Coaxial cable and Antenna Connection .............................................. 23 4.1.6 Insertion of RDU ................................................................................... 23 4.1.7 RDU Specifications Per band .............................................................. 24
 Confidential & Proprietary                                      4/28 Contents of Figure Figure 3.1 – Remote Unit Block Diagram ...................................................... 12 Figure 3.2 – Inside of Remote Unit ............................................................... 13 Figure 3.3 – ROU Outer Look ....................................................................... 15 Figure 4.1 – How to install ROU .................................................................... 17 Figure 4.2 – Dimension used to install ROU on the WALL ............................ 17
 Confidential & Proprietary                                      5/28  Section1                                             Safety & Certification Notice
 Confidential & Proprietary                                      6/28  “Only  qualified  personnel  should  handle  the  DAS  equipment.  Any  person  involved  in installation or service of the DAS should understand and follow these safety guidelines.”      -  Obey  all  general  and  regional  installation  and  safety  regulations  relating  to  work  on  high voltage  installations,  as  well  as  regulations  covering  correct  use  of  tools  and  personal protective equipment.  - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.  - When working with units outdoors, make sure to securely fasten the door or cover in an open position to prevent the door from slamming shut in windy conditions..  -  Use  this  unit  only  for  the  purpose  specified  by  the  manufacturer.  Do  not  carry  out  any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.    -  Any  DAS  system  or  Fiber  BDA  will  generate  radio  (RF)  signals  and  continuously  emit  RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 3-foot minimum clearance from the antenna while the system is operating.  -  Do  not  operate  this  unit  on  or  close  to  flammable  materials,  as  the  unit  may  reach  high temperatures due to power dissipation.  -  Do  not  use any  solvents,  chemicals,  or cleaning  solutions  containing  alcohol,  ammonia,  or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors.  - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm.  - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure.  - Allow sufficient fiber length to permit routing without severe bends.  - For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible.  - A readily accessible disconnect device shall be incorporated external to the equipment.
 Confidential & Proprietary                                      7/28 - This power of this system shall be supplied through wiring installed in a normal building.  If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device  - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote.   Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system.    All components connected to this device must operate in the frequency range of this device.  - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device.  -  The  head  end  unit  must  always  be  connected  to  the  Base  Station  using  a  direct  cabled connection.    This  system  has  not  been  approved  for  use  with  a  wireless  connection  via server antenna to the base station.  - Signal booster warning label message should include    - Certification     FCC:  This  equipment  complies  with  the  applicable  sections  of  Title  47  CFR  Parts 15,22,24,27 and 90(Class B)    UL/CUL:  This  equipment  complies  with  UL  and  CUL  1950-1  Standard  for  safety  for information technology equipment,including electrical business equipment    FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of  21 CFR Chapter 1, Subchaper J, Part 1040
 Confidential & Proprietary                                      8/28  Section2                                          System Overview            2.1 Purpose 2.2 SMDR-NH124
 Confidential & Proprietary                                      9/28 2.1  Purpose SMDR-NH124 is a coverage system for  in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities.   Shopping malls   Hotels   Campus areas   Airports   Clinics   Subways   Multi-use stadiums, convention centers, etc.  The  system  helps  improve  in-building  radio  environments  in  poor  condition  and  make  better poor  RSSI  and  Ec/Io.  By  providing  communication  services  at  every  corner  of  buildings,  the system enables users to make a call at any site of buildings.   The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods. The SMDR-NH124 system supports communication standards and public interface protocols in worldwide use.   Frequencies: VHF,UHF, 700MHz, 800MHz,850MHz 900MHz,1900MHz,2100MHz, etc.     Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc.   Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging, etc.  SMDR-NH124 is in modular structure per frequency. To provide desired frequency in a building, all you need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals with one optical cable, the system, in one-body type, does not require additional facilities whenever new frequency is added. The system is featured with the following:   Flexibiltiy & Scalabiltiy   Support fiber-optic ports up to 39   Clustering multiple-buildings (campus) as one coverage     Modular structures   Modular frequency upgrade     Plug-in type module     Multi-Band, Multi Operator
 Confidential & Proprietary                                      10/28   Signals with a plurality of service provider transmit simultaneously       Support multi-operator in a band     Low OPEX / CAPEX   Compact design     Upgradable design     Easy installation and maintenance   Web Based SNMP or GSM Modem or UDP support (Optional)  2.2  SMDR-NH124 ROU receives TX optical signals  from  ODU or OEU  and converts them  into RF signals. The converted  RF  signals  are  amplified  through  High  Power  Amp  in  a  corresponding  RDU, combined with Multiplexer module and then radiated to the antenna port. When receiving RX signals  through the  antenna  port,  this unit  filters  out-of-band signals  in a corresponding RDU and sends the results to Remote Optic Module to make electronic-optical conversion of them. After converted, the signals are sent to a upper device of ODU or OEU. ROU can be equipped with up to three RDUs (Remote Drive Unit) and the module is composed of maximal Dual Band.
 Confidential & Proprietary                                      11/28  Section3                                       Functional Description            3.1 General (Remote Optic Unit) 3.2 Compoent of SMDR-NH124 Remote Unit 3.3 Dimension
 Confidential & Proprietary                                      12/28 3.1  General (Remote Optic Unit) The following figure shows the block diagram of SMDR-NH124 Remote Unit.     Figure 3.1 – Remote Unit Block Diagram There are many components;  R-Optic : Remote Optical Unit  RCPU : Remote Central Processor Unit  RPSU(AC) :    Remote AC Power Supply Unit(When using the AC input power)  RPSU(DC) :    Remote DC Power Supply Unit(When using the DC input power)  RDU1-3 : Remote Drive Unit  MULTIPLEXER : Combine Unit  SIU : System Interface Unit
 Confidential & Proprietary                                      13/28 3.2  Component of SMDR-NH124 Remote Unit The following figure shows internal configuration of Remoe Unit with fully RF equipped.   Figure 3.2 – Inside of Remote Unit  Remote Unit receives TX optical signals from Head-End and converts them into RF signals. The converted RF signals are amplified through High Power Amp in  a  corresponding RDU, combined with Multiplexer module and then radiated to the antenna port. When  receiving  RX  signals  through  the  antenna  port,  this  unit  filters  out-of-band  signals  in  a corresponding  RDU  and  sends  the  results  to  Remote  Optic  Module  to  make  electronic-optical conversion  of  them.  After  converted,  the  signals  are  sent  to  a  upper  device  of  ODU.  ROU  can  be equipped with up to three RDUs (Remote Drive Unit)    The following table describes components on Remote Unit No. Unit Description Remark 1 RDU+BPF Remote Drive Unit Filter and high amplify TX signals; Filter and amplify RX signals; Remove other signals through BPF BPF is exclude from VHF+UHF module
 Confidential & Proprietary                                      14/28 2 RPSU Remote Power Supply Unit Input power: DC -48V, Output power: 27V,9V, 6V For 120V input of AC/DC; For -48V input of DC/DC  3 R-OPTIC Remote Optic Make RF conversion of TX optical signals; Convert RX RF signals into optical signals; Compensates optical loss Communicates with BIU/OEU though the FSK modem  4 RCPU Remote Central Processor Unit Controls signal of each unit Monitors  BIU/ODU/OEU  status  through  FSK  modem communication  5 Multiplexer Multiplexer Combine TX signals from 3 RDUs; Distribute RX signals to 3 RDUs; Enable you to use a single antenna port  6 Enclosure Enclosure to satisfy NEMA4;   Enable Wall/Rack Mount; Check  if  the  system  is  normal,  through  the  front  panel LED  7 SIU System Interface Unit Distribute power and signals of each module
 Confidential & Proprietary                                      15/28 3.3  Dimension   Figure 3.3 – ROU Outer Look  ROU is designed in a cabinet, and provides the following functions and features.  Item Spec. Remark Size(mm) 482.6(19“) x 258 x560, Including Bracket Weight 35.45 Kg Full Load Power consumption 265 W Operating Temperature -10 to +50°C Ambient Temperature
 Confidential & Proprietary                                      16/28  Section4                                           System Installation            4.1  ROU Installation 4.1.1  ROU Enclosure installation ROU is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4. ROU can be mounted into either of a 19” Standard Rack or on a Wall.   Basically, ROU has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the use of the Rack Mount Bracket, the bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket.
 Confidential & Proprietary                                      17/28  Figure 4.1 – How to install ROU  Figure 4.2 – Dimension used to install ROU on the WALL
 Confidential & Proprietary                                      18/28  ROU Wall Mount Installation  Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure.   Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.    Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove.
 Confidential & Proprietary                                      19/28   ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection.     ROU component ROU has the following components: No. Unit Description Remark Common Part Enclosure Including Rack & Wall cradle 1EA RCPU - 1EA R_OPTIC With SC/ACP adaptor 1EA RPSU Alternative DC-48V or AC 120V   1EA Multi-Plexer - 1EA Power Cable - MS Connector with 3 hole to AC 120 plug(AC) - MS Connector with 2 lug termination(DC)  Optional Part RDU+BPF 800PS,800PS+900I+Paging,850C,850C+700PS, 1900P+ AWS-1 RDU, VHF+UHF(NO BPF), Up to 3EA to be inserted
 Confidential & Proprietary                                      20/28 850C+700LTEC, 700LTEF+850C 700LTEF SISO RDU, 700LTEF SISO RDU  Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to inquire  and  control  state  of  each  module,  R_OPTIC  to  make  both  of  electronic-optical  and optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or to supply required power. In addition, RDU can be inserted and removed to provide service for desired band (Optional).  4.1.2  ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC  -48V  and RSPU for AC 120V  have the same  configuration and capacity while each of the units uses different input voltage from each other.  The following figure shows configuration of RPSUs for DC -48V and AC 120V.
 Confidential & Proprietary                                      21/28  MC Connector numbering Lug Naming RPSU Terminal naming Remark AC DC AC DC A AC_H -48V AC-H -48V  B AC_N GND AC-N IN_GND  C GND DC NC FG FG   Check if the connection is the same as one seen in the table above and make sure to turn the power ON.  4.1.3  Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic-  optical  conversion  of  RX  signals.  ROU  has  one  optical  module  in  it.  As  WDM  is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type. For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred with dirt,  it should be covered  with a  cap  during move. When  devices are  connected through optical cables, you need to clear them using alcohocol to remove dirt.
 Confidential & Proprietary                                      22/28 Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in  ROU,  you  need  to  coil  around  one  or  two  roll  of  cables  to  be  connected  with  the  optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø  to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm).  4.1.4  GND Terminal Connection ROU has one GND terminal port where is on bottom side, like below    -  Take off the GND terminal port from enclosure and connect to ground cable, then fix it the position of enclosure again -  The opposite end of the ground cable should connect to the communication GND of building      GND LUG
 Confidential & Proprietary                                      23/28 4.1.5  Coaxial cable and Antenna Connection -  The  coaxial  cables  which  are  connected  to  antenna  distribued  network  connect  to antenna  port  of  ROU.  Before  connection,  check  the  VSWR  value  of  coaxial  cable whether it is within specification using SITEMASTER . -  At this time, check if the Return loss have above 15Db or VSWR have below 1.5 -  The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and insects - The antenna connected to ROU is only serviced in inbuilding        4.1.6  Insertion of RDU ROU has slots to enable up to three RDU modules to be inserted into the unit. You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case. The table below shows types of RDU and CAVITY BPF: No Unit naming Cavity BPF RF CABLE Multiplexer Interface TX RX 1 RDU 800PS 800PS BPF TX CABLE 1EA RX CABLE 1EA BPF OUT RDM RX IN 2 RDU 850C 850C BPF TX CABLE 1EA RX CABLE 1EA BPF TX OUT BPF RX IN 3 RDU 1900P+AWS-1 1900P DUP TX/RX CABLE 1EA RDM AWS+1900P 4 RDU 800PS+900I+PA 800PS+900I+PA BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 5 RDU 850C+700PS 850C+700PS BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 6 RDU 850C+700PS(D) 850C+700PS BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 7 RDU VHF+UHF - TX CABLE 1EA RX CABLE 1EA - - 8 RDU E-VHF+UHF - TX CABLE 1EA RX CABLE 1EA - - 9 RDU 850C+700LTEC 850C+700LTEC BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN
 Confidential & Proprietary                                      24/28 10 RDU 700LTEF+850C 700LTEF+850C BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 11 RDU   700LTEF SISO 700LTEF SISO BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 12 RDU   700LTEF MIMO 700LTEF SISO BPF TX CABLE 2EA RX CABLE 1EA RDM TX OUT RDM RX IN 13 1900P(MIMO)+ AWS-1(MIMO) 1900P DUP TX/RX CABLE 1EA RDM AWS+1900P  4.1.7  RDU Specifications Per band Standard   Unit naming Description Frequency range TX(MHz) RX(MHz) iDEN 700P Public safety 758 to 775 793 to 805 700PS(D) Public safety 763 to 775 788 to 805 iDEN 800P Public safety 851 to 869 806 to 824 Cellular 850C Cellular 869 to 894 824 to 849 Iden 900I SMR 929 to 940 896 to 902 Paging 900 PA Paging 929 to 930 896 to 902 PCS 1900P PCS 1930 to 1995 1850 to 1915 AWS-1 AWS-1 AWS-1 2110 to 2155 1710 to 1755 - VHF Public safety 136 to 174 136 to 174 - UHF Public safety(Band1) 396 to 450 450 to 512 396 to 450 450 to 512  Public safety(Band2) 380 to 434 434 to 496 380 to 434 434 to 496 LTE 700LTE Long Term Evolution 728 to 757 699 to 716 777 to 787
 Confidential & Proprietary                                      25/28 700MHz Long Term Evolution Parameters Typical Remarks TX RX  Bandwidth 29MHz 28MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm     700MHz Long Term Evolution (MIMO) Parameters Typical Remarks TX RX  Bandwidth 29MHz 28MHz  Output power +25dBm +0dBm Total System Gain 45dB 50dB  input and output impedances 50 ohm   50 ohm     700MHz Public safety Parameters Typical Remarks TX RX  Bandwidth 12MHz 12MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm     700MHz Public safety (D Block) Parameters Typical Remarks TX RX  Bandwidth 17MHz 17MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm
 Confidential & Proprietary                                      26/28  800MHz Public safety Parameters Typical Remarks TX RX  Bandwidth 18MHz 18MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm     850MHz Cellular Parameters Typical Remarks TX RX  Bandwidth 25MHz 25MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm     900MHz iDEN & Paging Parameters Typical Remarks TX RX  Bandwidth 12MHz 6MHz  Output power +23dBm +0dBm Total System Gain 43dB 50dB  input and output impedances 50 ohm   50 ohm     1900MHz PCS Parameters Typical Remarks TX RX  Bandwidth 65MHz 65MHz  Output power +26dBm +0dBm Total System Gain 46dB 50dB
 Confidential & Proprietary                                      27/28 input and output impedances 50 ohm   50 ohm     1900MHz PCS(MIMO) Parameters Typical Remarks TX RX  Bandwidth 65MHz 65MHz  Output power +30dBm +0dBm Total System Gain 50dB 50dB  input and output impedances 50 ohm   50 ohm     1700MHz&2100MHz AWS-1 Parameters Typical Remarks TX RX  Bandwidth 45MHz 45MHz  Output power +26dBm +0dBm Total System Gain 46dB 50dB  input and output impedances 50 ohm   50 ohm     1700MHz&2100MHz AWS-1(MIMO) Parameters Typical Remarks TX RX  Bandwidth 45MHz 45MHz  Output power +30dBm +0dBm Total System Gain 50dB 50dB  input and output impedances 50 ohm   50 ohm     150MHz VHF Public safety Parameters Typical Remarks TX RX  Bandwidth 38MHz 38MHz 136~174MHz
 Confidential & Proprietary                                      28/28 Output power +24dBm -4dBm Total System Gain 39dB 50dB  input and output impedances 50 ohm   50 ohm     450MHz UHF Public safety Parameters Typical Remarks TX RX  Bandwidth(Band1) 116MHz 116MHz 396~450MHz(54MHz) 450~512MHz(62MHz) Band selection Bandwidth(Band2) 116MHz 116MHz 380~434MHz(54MHz) 434~496MHz(62MHz) Band selection Output power +24dBm -4dBm Total System Gain 39dB 50dB  input and output impedances 50 ohm   50 ohm     "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by  3.5  dB,  especially  where  the  output  signal  is  re-radiated and can  cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device."
RSS-GEN, Sec. 7.1.2  –  (transmitters)  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec  une  antenne  d’un  type  et  d’un  gain  maximal  (ou  inférieur)  approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée  quivalente  (p.i.r.e.)  ne  dépassepas  l’intensité  nécessaire à l’établissement d’une communication satisfaisante.  RSS-GEN, Sec. 7.1.2  –  (detachable antennas)  This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum  permissible  gain  and  required  antenna  impedance  for  each  antenna  type  indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.  Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.