SENA TECHNOLOGIES PARANISD1100 BLUETOOTH 422/485 ADAPTOR User Manual Manual Parani SD1100 v1 0

Sena Technologies,Inc. BLUETOOTH 422/485 ADAPTOR Manual Parani SD1100 v1 0

Users Manual

    Parani-SD1100  User Guide       Version 1.0.0  2010-04-19
 2User Guide for the Parani-SD1100 Version 1.0.0 Firmware version 1.0.X Printed in Korea  Copyright Copyright 2010, Sena Technologies, Inc. All rights reserved. Sena Technologies reserves the right to make changes and improvements to its product without providing notice.  Trademark Parani™ is a trademark of Sena Technologies, Inc. Windows® is a registered trademark of Microsoft Corporation. Ethernet® is a registered trademark of XEROX Corporation.  Notice to Users When a system failure may cause serious consequences, protecting life and property against such consequences with a backup system or safety device is essential. The user agrees that protection against consequences resulting from system failure is the user's responsibility. This device is not approved for life-support or medical systems. Changes or modifications to this device not explicitly approved by Sena Technologies will void the user's authority to operate this device.  Precautions and Safety Electricity Use only the supplied AC adapter. Use of unauthorized power adapter is not recommended. Electrical shock may result. Do not kink or crease the power cable or place heavy objects on the power cable. Fire can result from damaged power cables. Do not handle power plug and adapter with wet hands. Electrical shock may result. Immediately power off the product and unplug the AC adapter if smoke or odors emit from the product and adapter. Fire can result from improper use. Immediately power off the product and unplug the AC adapter if water or other liquids are present. Fire can result from improper use.  Product Parani-SD meets the RS-422/485. Do not wire with non-standard products. Damage to your products may result from improper use. Do not drop or subject the device to impact. Damage to your products may result from improper use. Keep away from harsh environments including humid, dusty, and smoky areas. Damage to your products may result from improper use. Do not use excessive force on the buttons or attempt to disassemble the device. Damage to your products may result from improper use. Do not place heavy objects on the product. Damage to your products may result from improper use.  FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver.
 3• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help.  Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation  IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Technical Support Sena Technologies, Inc. 210 Yangjae-dong, Seocho-gu Seoul 137-130, Korea Tel: (+82-2) 573-5422 Fax: (+82-2) 573-7710 E-Mail: support@sena.com Website: http://www.sena.com  Revision History  Revision Date  Name  Description V1.0.0  2010-04-19  Yh Moon  Initial Writing
 4Contents  1. Introduction  7 1.1. Overview ....................................................................................................................................7 1.2. Product Specification..................................................................................................................8 2. Configuration  10 2.1. Operation Modes......................................................................................................................10 2.2. LED Indicators.......................................................................................................................... 11 2.3. Serial Ports............................................................................................................................... 11 2.4. Data Bit..................................................................................................................................... 11 2.5. Reset to Factory Defaults.........................................................................................................12 2.6. Dipswitch ..................................................................................................................................12 2.7. Pairing Button...........................................................................................................................13 2.8. Software and Utility ..................................................................................................................14 2.9. ParaniWIN ................................................................................................................................14 2.10. ParaniUpdater ........................................................................................................................19 2.11. Terminal Program ...................................................................................................................20 3. Multiple Connection Mode  22 3.1. Overview ..................................................................................................................................22 3.2. Configuration ............................................................................................................................23 3.3. AT Commands..........................................................................................................................24 3.3.1. AT+MULTI,n...................................................................................................................24 3.3.2. AT+MLIST?....................................................................................................................24 3.3.3. ATHx, ATHbdaddr..........................................................................................................24 3.3.4. ATOx, ATObdaddr .........................................................................................................24 3.4. Notes ........................................................................................................................................25 4. RF Information  27 4.1. Radio Frequency Range ..........................................................................................................27 4.2. Number of Frequency Channel ................................................................................................27 4.3. Transmission Method ...............................................................................................................27 4.4. Modulation Method...................................................................................................................27 4.5. Radio Output Power.................................................................................................................27 4.6. Receiving Sensitivity ................................................................................................................27 4.7. Power Supply ...........................................................................................................................27 Appendix A: AT Commands  29 A.1. Terminology..............................................................................................................................29 A.1.1. AT Command.................................................................................................................29 A.1.2. AT Response .................................................................................................................29 A.1.3. Operation Mode.............................................................................................................29 A.1.4. Operation Status............................................................................................................29 A.1.5. Security..........................................................................................................................29 A.1.6. Symbols .........................................................................................................................30 A.2. Command Category.................................................................................................................30 A.3. Command Description .............................................................................................................31 A.3.1. ATZ..............................................................................................................................31 A.3.2. AT&F............................................................................................................................31 A.3.3. AT.................................................................................................................................31 A.3.4. AT+UARTCONFIG,Baudrate,Parity,Stopbit.................................................................31 A.3.5. AT+USEDIP?...............................................................................................................31 A.3.6. AT+BTINFO?...............................................................................................................32 A.3.7. AT+BTINQ?.................................................................................................................32 A.3.8. AT+BTLAST?...............................................................................................................32 A.3.9. AT+BTVER?................................................................................................................32 A.3.10. AT+MLIST?................................................................................................................32 A.3.11. AT+BTMODE,n..........................................................................................................33 A.3.12. AT+MULTI,n...............................................................................................................33
 5A.3.13. +++............................................................................................................................33 A.3.14. AT+SETESC,nn.........................................................................................................33 A.3.15. ATO (ATOx, ATObdaddr) ...........................................................................................34 A.3.16. AT+BTCANCEL.........................................................................................................34 A.3.17. AT+BTSCAN..............................................................................................................34 A.3.18. AT+BTSCAN,n,to.......................................................................................................34 A.3.19. AT+BTSCAN112233445566,to..................................................................................35 A.3.20. ATD............................................................................................................................35 A.3.21. ATD112233445566....................................................................................................35 A.3.22. ATH (ATHx, ATHbdaddr)............................................................................................35 A.3.23. AT+BTKEY=$string....................................................................................................36 A.3.24. AT+BTSD? ................................................................................................................36 A.3.25. AT+BTCSD................................................................................................................36 A.3.26. AT+BTFP,n.................................................................................................................36 A.3.27. AT+BTSEC,Authentication,Encryption......................................................................36 A.3.28. AT+BTNAME=$string................................................................................................37 A.3.29. AT+BTLPM,n.............................................................................................................37 A.3.30. AT+BTRSSI,n (Single Connection Mode Only) .........................................................37 A.3.31. AT&V..........................................................................................................................37 A.3.32. ATSnn? .....................................................................................................................38 A.3.33. ATSnn=mm................................................................................................................38 A.4. Command Validity ....................................................................................................................38 Appendix B: S-Register  40 B.1. S1: Force to Reconnect (default 1)..........................................................................................40 B.2. S3: Stream UART Policy (default 0) ........................................................................................40 B.3. S4: Enable Remote Name Query (default 1)...........................................................................40 B.4. S6: Enable Low Power Mode (default 0) .................................................................................40 B.5. S10: Enable Response Message (default 1) ...........................................................................40 B.6. S11: Enable Escape (default 1) ...............................................................................................40 B.7. S12: Clear Data Buffer When Disconnected (default 1) ..........................................................41 B.8. S13: Enable DCD Signal (default 1) ........................................................................................41 B.9. S14: Enable DTR Transfer (default 1) .....................................................................................41 B.10. S15: Enable Disconnect by DTR (default 0)..........................................................................41 B.11. S22: Faster Connection (default 0) ........................................................................................41 B.12. S23: Intercharacter Timeout Setting (default 0).....................................................................41 B.13. S24: Maximum Number of Inquiry Result (default 15)...........................................................41 B.14. S26: Intercharacter Timeout (default 0) .................................................................................41 B.15. S28: Escape Sequence Character (default 43) .....................................................................42 B.16. S31: Page Timeout (default 20) .............................................................................................42 B.17. S33: Inquiry Timeout (default 30)...........................................................................................42 B.18. S37: Supervision Timeout (default 5) ....................................................................................42 B.19. S43: COD (default 001F00) ...................................................................................................42 B.20. S44: COD Filter (default 0) ....................................................................................................42 B.21. S45: Inquiry Access Code (default 0x9E8B33)......................................................................42 B.22. S46: BD Address of Last Connected Device .........................................................................42 B.23. S48: Low Power Max Interval (default 5000).........................................................................43 B.24. S49: Low Power Min Interval (default 4500)..........................................................................43 B.25. S52: Low Power Timeout (default 5)......................................................................................43 B.26. S54: BD Address of Last Connected Device .........................................................................43 B.27. S55: BD Address of Last Connected Device .........................................................................43 B.28. S56: BD Address of Last Connected Device .........................................................................43 B.29. S57: Slave Disconnect Timeout (default 3) ...........................................................................43 B.30. S58: MAX TX POWER (default 0) .........................................................................................43 B.31. S59: Current Slave in Communication (default 0) .................................................................44 B.32. S60: Reconnect Time Interval (default 5) ..............................................................................44 Appendix C: Trouble Shooting  45 C.1. Data Loss or Malfunctioning ....................................................................................................45 C.1.1. Response Message.......................................................................................................45
 6C.2. Transmission Delay .................................................................................................................45 C.2.1. RF Processing Delay.....................................................................................................45 C.2.2. RF Transmission Environment ......................................................................................45 Appendix D: Warranty  47 D.1. GENERAL WARRANTY POLICY............................................................................................47 D.2. LIMITATION OF LIABILITY......................................................................................................47 D.3. HARDWARE PRODUCT WARRANTY DETAILS....................................................................47 D.4. SOFTWARE PRODUCT WARRANTY DETAILS ....................................................................48 D.5. THIRD-PARTY SOFTWARE PRODUCT WARRANTY DETAILS ...........................................48
 71. Introduction  1.1. Overview             Parani-SD1100 is a terminal device for wireless serial communication using Bluetooth 2.0+EDR technology that is an international standard of short range wireless communications. Parani-SD1100 can communicate with other Bluetooth devices; user may connect other Bluetooth devices that support the Serial Port Profile.  The working distance of Parani-SD1100 with default antenna is 100m    Parani-SD1100 has a compact design, which allows it to be placed conveniently into various devices or equipment. Its detachable antenna has the ability to optimize the quality and distance of wireless communications.   Parani-SD1100 supports FHSS (Frequency Hopping Spread Spectrum), which is a technique, native to Bluetooth that allows the Parani-SD1100 minimize radio interference while decreasing the likelihood of over-air hijacking. Parani-SD1100 also supports authentication and Bluetooth data encryption.  Parani-SD1100 can be configured and controlled by a set of AT commands. Users can easily configure Parani-SD1100 on a terminal program, such as HyperTerminal, and configure for wireless communication without modifying user’s existing serial communication program. User friendly ParaniWIN can also be used for easy setup on Microsoft Windows.
 81.2. Product Specification   Parani-SD1100 Serial Interface  One male DB9 serial port for data communication Serial UART speed up to 921.6kbps  Bluetooth v2.0 + EDR Profile: Serial Port Profile Class 1 Bluetooth Interface Working distance: Stub Antenna (M/N:AN2400-3306RS) Max Gain 1.40dBi           Manufacturer (Cortec Technology Inc.)                       - 100 metersDipole Antenna (M/N:R-AN2400-5801RS) Max Gain 3.17dBi         Manufacturer (Cortec Technology Inc.)                       - 300 metersDipole Antenna (M/N:R-AN2400-1901RS) Max Gain 5.37dBi Manufacturer (Cortec Technology Inc.)                       - 600 metersConfiguration  ParaniWIN, Modem AT command set Firmware Update  ParaniUpdater Diagnostic LED  Power, Mode, Connect, Serial Rx/Tx Power  Supply voltage: 5V ~ 12V DC Power consumption: 80mA@5VD Max Environmental  Operating temperature: -20 ~ 70 oC Storage temperature: -40 ~ 85 oC Humidity : 90% (Non-condensing) Physical properties  - Dimension (L x W x H)     74 x 31 x 16 (mm)     - Weight   24g  Approvals  FCC(A) , CE, MIC, CE, TELEC, SIG, IC Warranty  3-year limited warranty
 9
 102. Configuration   2.1. Operation Modes  In addition to the serial port configurations the Parani-SD1100 also requires some settings for Bluetooth. For getting the most out of Parani-SD1100, user should understand the following Bluetooth connection schemes.  A Bluetooth device can play a role as a master or slave. Master tries to connect itself to other Bluetooth devices, and slave is waiting to be connected from other Bluetooth devices. A Bluetooth connection is always made by a pair of master and slave devices. A slave can be in two modes, Inquiry Scan or Page Scan mode. Inquiry Scan mode is waiting for a packet of inquiry from other Bluetooth device and Page Scan mode is waiting for a packet of connection from other Bluetooth device. Every Bluetooth device has its unique address, called BD (Bluetooth Device) address, which is composed of 12 hexa-decimal numbers.  Parani-SD1100 has 4 operation modes as follows. Each mode can be identified with LED indicators as illustrated in next section.   Table 2-1 The Parani-SD1100 Operation Modes  Mode Description Mode0  In this mode, there is no response when power on or software reset, and Parani-SD1100 is just waiting for AT command input. Neither master nor slave is assigned to Parani-SD1100 in mode0. User can change the configuration parameters of Parani-SD1100 in this mode.  Parani-SD1100 must be in Mode0, when it is directly controlled by AT commands.  The factory default is set to Mode0. Mode1  Parani-SD1100 tries to connect the last connected Bluetooth device. Parani-SD1100 in Mode1 is to be a master and tries to connect the last connected Bluetooth device. Parani-SD1100 always stores the BD address of the Bluetooth device to which Parani-SD1100 has connected last. When Parani-SD1100 is initially used or after hardware reset, there is no BD address stored in Parani-SD1100. In this case, Mode1 will not be able to work properly. The mode change to Mode1 can be made after Parani-SD1100 succeeds to connect to one other Bluetooth device. Once changed to Mode1, Parani-SD1100 will try to connect automatically the last connected Bluetooth device whenever the unit is powered on or software reset. Parani-SD1100 in Mode1 cannot be discovered or connected by other Bluetooth devices. Mode2  Parani-SD1100 is waits for a connection from the last connected Bluetooth device. Parani-SD1100 in Mode2 is to be a slave and waiting for the connection only from the last connected Bluetooth device. Just like Mode1, if there is no BD address stored in Parani-SD1100, the mode change from other operation modes to Mode2 is not work properly. Once changed to Mode2, Parani-SD1100 will wait for the connection from the last connected Bluetooth device whenever the unit is powered on or software reset. Parani-SD1100 in Mode2 cannot be discovered or connected to Bluetooth devices other than the last connected device. Mode3  Parani-SD1100 is waiting for the connection from any other Bluetooth devices. In Mode 3 the Parani-SD1100 is discoverable and can be connected to by other Bluetooth devices.
 112.2. LED Indicators  RS422/485-Tx and RS422/485-Rx LED will flash accordingly when data is transmitted. For small data transmissions, it may be hard to recognize the quick flashing action of the LED. Charge Led and Low battery LED will be off, if you don’t use battery pack.  Table 2-2 The Parani-SD1100 LED Indicators Indicator  Power LED  Standby LED  Connect LED  Indicator Mode0  Green   ┏━━━━━ Red     ┏━━━━━  Mode0 Mode1  Green   ┏━━━━━   Green (every 1 sec)  ┏┓ Mode1 Mode2  Green   ┏━━━━━   Green (every 3 sec)  ┏┰┓ Mode2 Mode3  Green   ┏━━━━━   Green (every 3 sec)  ┏┰┓ Mode3 Connected  Green   ┏━━━━━   Green   ┏━━━━━━━ Connected Indicator Power LED Standby LED Connect LED Indicator Mode0  Green   ┏━━━━━ Red     ┏━━━━━  Mode0 Mode1  Green   ┏━━━━━  Green (every 1 sec)  ┏┓ Mode1   2.3. Serial Ports  The applicable settings for serial ports are as follows.  Table 2-3 The Parani-SD1100 Serial Port Settings Serial Port Settings  Values Baud rate  1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800, 921600 Data bite  8 Parity  No parity, Even parity, Odd parity Stop bit  1, 2 Hardware Flow Control  No Use  The values in box are the factory defaults.    2.4. Data Bit  Parani-SD1100 supports only 8 data bit. In the case of 7 data bit and even/odd parity, use 8 data bit and none parity. At this time, master and slave are Parani-SD, Parani-ESD or Parani-MSP series. But 7 data bit and none parity is not support.
 122.5. Reset to Factory Defaults  To set all the configuration settings to its factory default parameters, press the reset button, depicted in Fig. 3-1. Press and hold (for at least 1 sec) the reset button with a narrow pointed tool like paper clip. Reset works only when power is on.   2.6. Dipswitch  With the combination of 4 slot dipswitches, RS422/485 select, baud rate 9600 select, 485 echo and termination on/off control can be set.  ParaniWIN or terminal program should be used to set these speeds. To set a baud rate not shown below the dipswitches should be in the S/W Config setting. When in the S/W Config setting the baud rate will go back to 9600 as default.  Table 1 Select by Dipswitches 422 485  Select     Table 2 Termination Select by Dipswitches Off On Termination     Table 3 485 Echo Control by Dipswitches Off On 485 Echo Control       Table 4 Baudrate Settings by Dipswitches AT Command  9600 Baudrate
 132.7. Pairing Button  Parani-SD1100 provides Pairing Button for instant configuration without a PC to make an automatic connection between two Parani-SD1100s. In this example we will refer to the two Parani-SD1100s as SD1 and SD2. (Only single connection mode)  Step 1. Turn on SD1 and SD2 and reset both of them by pressing Factory Reset Button. Step 2. Press the Pairing Button of SD1 for 2 seconds until Mode LED blinks 3 times every 3 seconds. Keep the power ON. Step 3. Press the Pairing Button of SD2 for 2 seconds until Mode LED blinks 3 times every 3 seconds. Now press again the Pairing Button for 2 seconds until Mode LED blinks every second. Step 4. Wait for SD1 & SD2 to connect to each other until the Connect LED’s of SD1 and SD2 blink every 1 second. It takes about 10 seconds to make a connection. If there are many Bluetooth devices nearby, it may take longer. Step 5. Turn SD1 off and on. Mode LED blinks twice in green every 3 seconds. Step 6. Turn SD2 off and on. Mode LED blinks in green every second. Step 7. Now SD1 and SD2 are configured to make automatic connection to each other, whenever they are powered on.  Using a pair of Parani-SD1100 in this fashion is similar to that of using a wireless serial cable.  * Note: When using the pairing buttons, the Command Response option will be deactivated automatically. The Parani-SD1100 will not send the response messages such as OK, Connect and Disconnect.   Table 2-8 Pairing Process by Pairing Button SD1 Status LED  SD2 Status LED 1. Factory reset  Mode0  Mode LED turns on  1. Factory reset Mode0  Mode LED turns on 2. Push pairing button Mode3  Mode LED blinks 3 times every 3 seconds2. Push pairing button Mode3  Mode LED blinks 3 times every 3 seconds      3. Push pairing button again Mode1  Mode LED blinks every second 4. Connected  Slave  Connect LED blinks every second 4. Connected  Master  Connect LED blinks every second  Using pairing button, users can make a pairing connection between a Parani-SD unit and other Bluetooth devices.  Step 1. Turn on SD1 and reset it by pressing Factory Reset Button. Step 2. Press the Pairing Button of SD1 for 2 seconds until Mode LED blinks 3 times every 3 seconds. Keep the power ON. Step 3. Users can discover and connect to SD1 by using the software or user interface of other   Bluetooth device that they want to connect from. Step 4. When they are connected, the Connect LED of SD1 blinks every 1 second.   Step 5. Turn off and on. Mode LED blinks twice in green every 3 seconds. Step 6. Now SD1 is waiting for a connection from the last connected Bluetooth device. The last   connected Bluetooth device can connect to SD1.  Table 2-9 Pairing Process with other Bluetooth device by Pairing Button SD1  Status  LED  Other Bluetooth Device  Status1. Factory reset  Mode0  Mode LED turns on     2. Push pairing button  Mode3  Mode LED blinks 3 times every 3 seconds
 14      3. Inquiry and connect to SD1   4. Connected  Slave  Connect LED blinks every second 4. Connected  Master 2.8. Software and Utility  This configuration software and utility for firmware update is included with the product, which also can be downloaded from http://www.sena.com  Table 2-10 Configuration Software Software Purpose  Operating System ParaniWIN    Configuration  MS Windows 98SE or Higher   ParaniUpdater    Firmware Update  MS Windows 98SE or Higher    2.9. ParaniWIN  ParaniWIN is a program that runs on Microsoft Windows for the configuration of Parani-SD1100. Install ParaniWIN on your computer. Plug a Parani-SD1100 into the serial port of the computer and turn on the power. Run ParaniWIN.       Figure 2-1 Serial Port Setting  Set each option properly and click [Confirm]. If the settings of the Parani-SD1100 are different from the ParaniWin, an error message will pop up. If the Parani-SD1100 is in the status of connection, warning message will pop up. Then the current connection can be cancelled by [Disconnect] button on the main window.
 15 Figure 2-3 Main Window   Figure 2-4 Information Window    Serial port settings can be changed by <Start Configuration> and <ParaniWIN Configuration> of ParaniWIN in the menu bar at upper left corner of the window without re-running the ParaniWIN program.
 16  Figure 2-5 Menu Bar at Upper Left corner of ParaniWIN    When the ParaniWin software is able to access the Parani-SD1100 properly, the icons in the left side window come will become available for use.  In device configuration window, hardware reset can be executed or operation mode and RS422/485 can be configured as well. Security option also can be configured in this window.     Figure 2-6 Device Setting Window    Parani-SD1100 supports two security options, Authentication and Encryption. If you enable the Authentication option, you must also enter a Pin Code value. If the authentication is enabled, the connection, between the Master and Slave device must share the same Pin Code. In case that Parani-SD1100 connects to another Bluetooth device, that requires authentication, you must know the other device’s Pin Code. In general, most Bluetooth devices have a pincode of 1234 or 0000. If you check Encryption option, the Parani-SD1100 will encrypt packets and sent to the device. The Encryption options works well in case that only one of the devices between Master and Slave use the Encryption option.
 17 Parani-SD1100 has 4 response messages, ‘OK’, ‘ERROR’, ‘CONNECT’, and ‘DISCONNECT’. In some cases, these responses can affect the host system unexpectedly. To prevent this, user can set the Command response to ON or OFF.  For Parani-SD1100, hardware flow control can be configured only by dip switch. And parity, stop bit can be configured only SW config mode. Thus H/W Flow Control option will not work in this case. When the dipswitch value isn’t ATcommand mode, the Baud Rate menu will be disabled.    Click [Apply] button to apply any changes made to the Parani-SD1100.  Connection(out) icon will show the following window to search and connect other Bluetooth devices.        Figure 2-7 Connection (out) Window      Click [Search] button to search nearby Bluetooth devices. Once several Bluetooth devices has been found, select one of the devices and click the [Connect] button. The selected Bluetooth device must be discoverable and connectable. Click [Disconnect] button to cancel the connection.    After the connection has been established, you will be able to test signal strength by pushing the START button.
 18 Figure 2-8 Signal Strength Test  The signal strength test shows LInkQuality and RSSI values. The closer LinkQuality is to 255 and RSSI is to 0, this means the Parani-SD1100 has a good connection to the connected Bluetooth device. In general, the wireless connectivity is at its best within 10 meters. You can push the STOP button at anytime in order to terminate the signal strength test. The signal strength test will continue until the STOP button is pushed. If you close the ParaniWIN Window without pushing the STOP button, you must restart Parani-SD1100 to terminate the test.  Connection(in) icon will show the following window, which enables the Parani-SD1100 to wait for a connection from another Bluetooth device. If the waiting time is set to 0, Parani-SD1100 will continually wait for connection until [Cancel] button is clicked.   Figure 2-9 Connection (in) Window
 19  If the Connection Wizard icon is clicked, an easy to use pairing menu will appear:    Figure 2-10 Connection Wizard Window  In this example we will refer to the two Parani-SD1100s as SD1 and SD2 respectively. To use this menu, please do the following:    Step 1.  Connect SD1 and then push the START button. Step 2.  Disconnect SD1, connect SD2 and then push the Next button after setting up Slave configuration. At this time, the dip switch value should be ATcmd mode. The flow control setting can be changed only through dip switch. Step 3.  Disconnect SD2, once again connect SD1 and then push the Finish button. The pairing configuration should be completed. Make sure that each Parani-SD1100’s connect LED is on. At this point, when both Parani-SD1100’s restart the connection will be established automatically.    2.10. ParaniUpdater  Parani-SD1100 supports firmware updates. You can download new firmware images for the Parani-SD1100 at http://www.sena.com. With the ParaniUpdater, you can update the firmware of Parani-SD1100 by selecting the firmware image file and pushing Start button.  * Note: DO NOT power off Parani-SD1100 while the firmware update is progressing, this may damage the Parani-SD1100.
 20 Figure 2-11 ParaniUpdater Window   2.11. Terminal Program  A terminal program is typically an application that will enable a PC to communicate directly with a modem. If you are using Windows 98SE or higher version of Windows, HyperTerminal program is included as part of the operating system. Parani-SD1100 provides some extended AT commands for configuration of the Parani-SD1100.    This manual will explain the method using HyperTerminal. If you need to install HyperTerminal, click start>setting>control panel>add/remove programs. For more precise details on HyperTerminal installations, please refer to Microsoft Windows Help section. .   Figure 2-12 HyperTerminal   Attach Parani-SD1100 to serial port of host computer and power on the Parani-SD1100. Check Mode LED. (See 3.2)
 21 Make sure that the Connect LED is turned off and the Stanby LED is turned on before attempting to send any kind of AT commands to the Parani-SD1100. Then launch HyperTerminal, it can usually be found in start >programs >accessories >communication >HyperTerminal. Select the Serial port that Parani-SD1100 is connected to.  Select the Serial port setting in the window displayed, please make sure the serial settings in Hyperterminal are set to the same settings as the Parani-SD1100’s serial settings.  To view the AT commands that are being typed, you will need to enable the local echo option. Go to File->Properties->Settings->ASCII setup and select the “Echo typed characters locally” option.  For expanded AT commands, please refer to Appendix A. AT commands.  Example of AT commands:                  at+btinfo?  00015B446655,SD1100v2.0.0-446655,MODE0,STANDBY,0,0,NoFC  OK atd 000195000001 OK  CONNECT 000195000001
 223. Multiple Connection Mode   3.1. Overview  Parani-SD1100 supports multiple connections up to 4 slave units. There are two types of multiple connection modes: Multi-Drop Mode and Node Switching Mode.    Figure 4-1 Multi-Drop Mode  In Multi-Drop Mode a master unit can connect to maximum 4 slave units at the same time and they transfer data bi-directionally as in Figure 4-1.    Figure 4-2 Node Switching Mode  In Node Switching Mode, the master unit maintains multiple connections with maximum 4 slave units but only one connection with one slave unit is active and data is transferred as shown in Figure 4-2. Active slave is selected by AT commands.              On communication after connecting  +++  OK  ATO1 – Communicating with #1 Slave  +++  OK  ATO000195000003 – Communicating with slave of BD 000195000003
 233.2. Configuration   All the slaves should be in the status of waiting for connection either in Mode 2 or Mode 3 and the master unit tries to connect to the slave units. The master unit needs to be configured to work in a multiple connection mode using AT+MULTI,x command, which makes master reboots after execution.   Table 4-1 AT+MULTI,x  AT+MULTI,0   Single Connection Mode AT+MULTI,1  Multi-Drop Mode AT+MULTI,2   Node Switching Mode   Table 4-2 Configuration of a Multiple Connection Mode  Manual Connection  Automatic Connection ATD000195000001 CONNECT000195000001 +++ OK ATD000195000002 CONNECT000195000002 +++ OK ATD000195000003 CONNECT000195000003 +++ OK ATD000195000004 CONNECT000195000004 +++ ATS46=000195000001 OK ATS54=000195000002 OK ATS55=000195000003 OK ATS56=000195000004 OK AT+MULTI,1 or AT+MULTI,2 OK AT+BTMODE,1 After rebooted automatically master tries to connect to slaves    After input the BD addresses of the slave units into 4 S-registers S46, S54, S55 and S56 and then set operation mode as MODE1, users can use multiple connection function. If S-registers have available slaves’ address, AUTO CONNECT message will be displayed following corresponding TASK.                TASK1 OK – AUTO CONNECT  TASK2 OK   TASK3 OK – AUTO CONNECT  TASK4 OK
 243.3. AT Commands   3.3.1. AT+MULTI,n  Select a multiple connection mode. Refer to Table 4-1 for descriptions.   3.3.2. AT+MLIST?  It shows the current mode, the connection status and the BD addresses of slaves.                 3.3.3. ATHx, ATHbdaddr  Using the ATH command, connections with all slaves or only connections with specific slaves can be disconnected selectively  Table 4-3 ATH  ATH  Disconnect all the slaves. ATHx (ATH1, ATH2, ATH3, ATH4)  Disconnect the slave which belongs to the TASK x. ATHbdaddr (ATH000195000001)  Disconnect the slave with specified BD address.   3.3.4. ATOx, ATObdaddr  Using the ATO command, the communication status with the last active slave or a specific slave can be set to online (only in Node Switching Mode).  Table 4-4 ATO  ATO  Communicate with the slave recently communicated. ATOx (ATO1, ATO2, ATO3, ATO4)  Communicate with the slave which belongs to the TASK x. ATObdaddr (ATO000195000001)  Communicate with the slave with specified BDaddress.    at+mlist?   CURRENT MODE: MULTI DROP  TASK1 – 000195000001  TASK2 – 000195000002  TASK3 – DISCONNECT  TASK4 - 000195000004  OK
 253.4. Notes   When large data exchange occurs in Multi-drop mode without flow-control enabled, the master unit may experience data loss. It may also experience occasional disconnections and/or system rebooting especially when bi-directional communication happens. It is strongly recommended to perform extensive performance test before any real world field applications. The master unit would try to connect all slave units specified by S-register 46, 54, 55 and 56. If non-existing or inactive slave addresses are entered in these S-registers, the overall performance will degrade due to frequent connection trials to non-existing/inactive slaves. It may also force disconnections for overall performance and outputs disconnect messages repeatedly.  Node-switching mode provides nearly equivalent performance as single connection mode. It is always recommended to use flow-control for both of Multi-Drop Mode and Node Switching Mode.
 26
 274. RF Information   4.1. Radio Frequency Range  2.402~2.480GHz   4.2. Number of Frequency Channel  79 channels   4.3. Transmission Method  FHSS (Frequency Hopping Spread Spectrum)   4.4. Modulation Method  GFSK (Gaussian-filtered Frequency Shift Keying) Pi/4 DQPSK (pi/4 rotated Differential Quaternary Phase Shift Keying) 8DPSK (8 phase Differential Phase Shift Keying)   4.5. Radio Output Power  Products Radio Output Power Parani-SD1100 +13dBm   4.6. Receiving Sensitivity  Products Radio Output Power Parani-SD1100 -88dBm   4.7. Power Supply  Products Radio Output Power Parani-SD1100  DC5.0 ~ 12V
 28
 29Appendix A: AT Commands    A.1. Terminology    A.1.1. AT Command  AT command set is the HTin fact standardTH HTlanguageTH for controlling HTmodemsTH. The AT command set was developed by HTHayesTH and is recognized by virtually all HTpersonal computerTH modems. Parani-SD provides the extended AT command set to control and configure the serial parameters and Bluetooth connection.    A.1.2. AT Response  Parani-SD replies to AT commands with 4 kinds of message, ‘OK’, ‘ERROR’, ‘CONNECT’ and ‘DISCONNECT’.    A.1.3. Operation Mode  Mode Description Mode0  Waiting for AT commands Mode1  Attempting to connect the last connected Bluetooth device Mode2  Waiting for the connection from the last connected Bluetooth device Mode3  Waiting for the connection from any other Bluetooth device    A.1.4. Operation Status  Status Description Standby  Waiting for AT commands Pending  Executing tasks Connect  Transmitting data    A.1.5. Security  Security Description Authentication  Pin Code (or Pass key) Encryption  Data encryption
 30A.1.6. Symbols  The symbols are used for the description of command syntax as follows:  Symbols Meaning  ASCII Code  Carriage return  0x0D  Line feed  0x0A  Carriage return + Line feed   112233445566  Bluetooth device address   N or m  One digit decimal number   to  Timeout in seconds     A.2. Command Category  Command Category  Index  AT Commands RESET 1 2 ATZ AT&F SERIAL PORT  3 4 AT AT+UARTCONFIG,b,p,s Information 5 6 7 8 9 10 AT+USEDIP? AT+BTINFO? AT+BTINQ? AT+BTLAST? AT+BTVER? AT+MLIST? Mode 11 12 AT+BTMODE,n AT+MULTI,n Status 13 14 15 16 17 18 19 +++ AT+SETESC,nn ATO AT+BTCANCEL AT+BTSCAN AT+BTSCAN,n,to AT+BTSCAN112233445566,to Connection 20 21 22 ATD ATD112233445566 ATH Security 23 24 25 26 27 AT+BTKEY=$string AT+BTSD? AT+BTCSD AT+BTFP,n AT+BTSEC,a,e BLUETOOTH Miscellaneous 28 29 30 AT+BTNAME=$string AT+BTLPM,n AT+BTRSSI,n S-REGISTER 31 32 33 AT&V ATSnn? ATSnn=mm
 31A.3.   Command Description   A.3.1. ATZ  Response  OK Purpose  Software Reset Description  This has the same effects as Powercycling the unit. This command disconnects any connected Bluetooth device, and stops ongoing tasks. After rebooting, the status will be decided by the preset operation mode. Some AT commands require the ATZ command be run so that the commands can take effect.  A.3.2. AT&F  Response  OK Purpose  Hardware reset Description  This has the same effect as initialization by pressing the factory reset button. All parameters are initialized to factory defaults.    A.3.3. AT  Response  OK Purpose  Check the connection status with host equipment Description  Check if the connection to host equipment is operating normally. The serial parameters of Parani-SD must be same as those of host equipment. If not, the Parani-SD will not respond or ‘ERROR’ message will appear or an abnormal sequence of strings will appear.  A.3.4. AT+UARTCONFIG,Baudrate,Parity,Stopbit  Response  OK Purpose  Set Serial parameters Parameters  Baudrate = 1200/2400/9600/14400/19200/38400/57600/115200/230400/460800/ 921600 (Default=9600) Parity=N/E/O (Default=N) Stopbit=1/2 (Default=1) Description  The Serial parameters can be set or changed only if SW config mode is selected in dip switch. The factory default is 9600, N, 1. To take effect the ATZ command must be used or Powercycle the unit. Example  AT+UARTCONFIG,115200,N,1  A.3.5. AT+USEDIP?   Response  m Purpose  Check the Baud rate set by the dip switch Description  m=0: Dip switches are set to ‘S/W Config’ m=1: Please view the dipswitches to view your baud rate.
 32A.3.6. AT+BTINFO?  Response  112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl OK Purpose  Display Bluetooth settings Description  The current Bluetooth settings are displayed including BD address, Device name, Operation mode, Operation status, Authentication, Data Encryption, and Hardware Flow Control. The initial value of Device name is ‘PSD1100v2.0.0-445566’. PSD stands for Parani-SD, v2.0.0 for the version of firmware, and 445566 for the last 6 digits of BD address. Mode=MODE0/MODE1/MODE2/MODE3 Status=STANDBY/PENDING/CONNECT Auth=0/1 (Authentication is not activated when 0) Encrypt=0/1 (Encryption is not activated when 0) FlowControl=HWFC/NoFC Example  000B530011FF,SENA,MODE0,PENDING,1,1,HWFC  A.3.7. AT+BTINQ?   Response  112233445566,FriendlyName,CoD 112233445566,FriendlyName,CoD 112233445566,FriendlyName,CoD OK Purpose  Search Bluetooth devices nearby Description  The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD addresses, Device names, and Class of device. Maximum 15 devices are scanned for 30 seconds. (Default 15 value in S-register 24)  A.3.8. AT+BTLAST?  Response  112233445566 Purpose  Display the BD address of the last connected device Description  The Bluetooth device last connected to this Parani-SD is displayed with its BD address.  A.3.9. AT+BTVER?  Response  SD1100v2.0.0 OK Purpose  Display device firmware version Description  Display device firmware version  A.3.10. AT+MLIST?  Response  CURRENT MODE:SINGLE CONNECTION MODE OK Purpose  Display the current multiple connection mode and connected slave’s Bluetooth addresses. Description  Display current mode(SINGLE CONNECTION MODE, MULTI-DROP MODE, NODE SWITCHING MODE) and connected slave Bluetooth address. Example  AT+MLIST?
 33CURRENT MODE: MULTI-DROP MODE TASK1 – 000195000001 TASK2 – DISCONNECT TASK3 – DISCONNECT TASK4 – 000195000004  A.3.11. AT+BTMODE,n  Response  OK Purpose  Set operation mode Parameters  n=0: MODE0 (Default) n=1: MODE1 n=2: MODE2 n=3: MODE3 Description  When the operation status is ‘Pending’ currently, change the status to ‘Standby’ with AT+BTCANCEL prior to this command. To take effect the ATZ must be executed or Powercycle the unit Example  AT+BTMODE,2 OK ATZ  A.3.12. AT+MULTI,n  Response  OK Purpose  Set multiple connection mode Parameters  n=0: Single Connection Mode (Default) n=1: Multi-Drop Mode n=2: Node Switching Mode Description  Set single connection mode, multi-drop mode or node switching mode.  A.3.13. +++  Response  OK Purpose  Convert the operation status of ‘Connect’ to ‘Standby’ Description  In ‘Connect’ status, data from host is transmitted to the other side Bluetooth device, and any AT command is not accepted but this command, which is not echoed on the screen. When Parani-SD encounters a character ‘+’ from host, it stops the data transmission and waits for next 2 characters. If the next 2 characters aren’t both ‘+’, it restart to transmit data including the first ‘+’ as well. If not, it converts the operation status to ‘Standby’. If the data from host includes ‘+++’, it will convert the operation status to ‘Standby’. Notice that Parani-SD holds data transmission when it encounters ‘+’, until receiving next character. ‘+’ is an escape sequence character by default, which is changeable by AT+SETESC.  A.3.14. AT+SETESC,nn  Response  OK Purpose  Change the escape sequence character Description  Escape sequence character set to ‘+’ by default is changeable.   The parameter nn must be a printable character.
 34Example  AT+SETESC,42  A.3.15. ATO (ATOx, ATObdaddr)  Response  None Purpose  Convert the operation status of ‘Standby’ to ‘Connect’ Description  You can convert the operation status of ‘Standby’ to ‘Connect’ ready to transmit data. In Node Switching mode, a specific slave can be specified to become an active connection by specifying the connection number or the Bluetooth address. Example  ATO ATO3 ATO000195000001  A.3.16. AT+BTCANCEL  Response  OK Purpose  Terminate the current task Description  This terminates a current executing task, such as Inquiry scan and Page scan, then converts the operation status to ‘Standby’  A.3.17. AT+BTSCAN  Response  OK CONNECT 112233445566 Purpose  Wait for inquiry and connection from other Bluetooth devices Description  This allows the inquiry and connection from the other Bluetooth devices. The operation status will be in ‘Pending’ after this command. When connection is made and released, the operation status is back to ‘Pending’. To convert the operation status to ‘Standby’ AT+BTCANCEL must be used. This has the same effect as AT+BTSCAN, 3, 0. When connection is made with other Bluetooth device, response will be ‘CONNECT’ with its BD address.  A.3.18. AT+BTSCAN,n,to  Response  OK CONNECT 112233445566 or OK ERROR Purpose  Wait for inquiry and connection from other Bluetooth devices for a given duration Parameters  n=1: Allows Inquiry scan n=2: Allows Page scan n=3: Allows both of Inquiry scan and Page scan to= Time duration in seconds Description  For the given to, Parani-SD is waiting for the inquiry and connection from other Bluetooth devices. If the parameter of to is 0, it will wait forever. When connection is made with other Bluetooth device, response will be ‘CONNECT’ with its BD address. If there is no connection made within this time duration, response is ‘ERROR’ and the operation status becomes to ‘Standby’.
 35Example  AT+BTSCAN,2,30  A.3.19. AT+BTSCAN112233445566,to  Response  OK CONNECT 112233445566 or OK ERROR Purpose  Wait for connection by a Bluetooth device with a given BD address Parameters  112233445566=BD address to= time duration in seconds Description  Parani-SD will wait to be connected to by the Bluetooth device with the given BD address. If the parameter of to is 0, it will wait forever. When connection is made with the Bluetooth device, response will be ‘CONNECT’ with its BD address. If there is no connection made within this time duration, response is ‘ERROR’ and the operation status becomes ‘Standby’. Example  AT+BTSCAN000B530011FF,30  A.3.20. ATD  Response  OK CONNECT 112233445566 or OK ERROR Purpose  Connect to the last connected Bluetooth device Description  Parani-SD saves the BD address of the Bluetooth device most recently connected to.   If it fails to make a connection, response will display an ‘ERROR’.  A.3.21. ATD112233445566  Response  OK CONNECT 112233445566 or OK ERROR Purpose  Connect to a specific Bluetooth device with a given BD address Parameters  112233445566 = BD address Description  Parani-SD attempts to connect to the Bluetooth device with the given BD address. To make successful connection, the Bluetooth device must be in Page scan mode. This attempt continues for 5 minutes. If it fails to make connection, response is ‘ERROR ’. Example  ATD000B530011FF  A.3.22. ATH (ATHx, ATHbdaddr)  Response  OK DISCONNECT Purpose  Release the current connection
 36Description  The current Bluetooth connection will be disconnected. It takes about Supervision Timeout(S37) to detect an abnormal disconnection such as power off and moving out of service range. In multiple connection modes, a specific connection can be specified to be disconnected by specifying the connection number or the Bluetooth address The response message of ‘DISCONNECT’ may be displayed on disconnection depending on the disconnection condition. You can make it not displayed using S10 register. Example  ATH ATH3 ATH000195000001  A.3.23. AT+BTKEY=$string  Response  OK Purpose  Change pin code Parameters  $string= New pin code (Default=”1234”) Description  Pin code is a string, which allows up to 16 alpha-numeric characters. Based on this pin code, Parani-SD generates a link key which is used in actual authentication process Example  AT+BTKEY=”apple”  A.3.24. AT+BTSD?   Response  112233445566 OK Purpose  Display a list of Bluetooth devices sharing the same pin code Description  Once a connection is made with a pin code, Parani-SD saves the Bluetooth device with its link key, generated by the pin code. The connection to a device listed in Parani-SD can be made automatically without the authentication process. The maximum number kept on the list is 7.  A.3.25. AT+BTCSD  Response  OK Purpose  Clear the list of Bluetooth devices sharing the same pin code Description  This clears the list of Bluetooth devices linked with the same key in flash memory. To take effect the ATZ command must be used or Powercycle the unit.    A.3.26. AT+BTFP,n  Response  OK Purpose  Set generation of link key every time of connection Parameters  n=0: Inactivate (Default) n=1: Activate Description  If n is set to 1, Parani-SD asks for the pin code every time a connection is made. This can be used to increase security.  A.3.27. AT+BTSEC,Authentication,Encryption  Response  OK
 37Purpose  Set authentication and data encryption Parameters  Authentication=0: Inactivate (Default) Authentication=1: Activate Encryption=0: Inactivate (Default) Encryption=1: Activate Description  If the authentication is activated, the pin code must be set by AT+BTKEY command. Data encryption cannot be used when authentication is not enabled, i.e. Authentication=0 and Encryption=1 will not work properly.  A.3.28. AT+BTNAME=$string  Response  OK Purpose  Change device name Parameters  $string= New device name (Default=”PSDv2.0.0-445566”) Description  Parani-SD can have a user friendly name for easy identification. The name allows up to 30 alpha-numeric characters. Example  AT+BTNAME=”My-Parani-SD”  A.3.29. AT+BTLPM,n  Response  OK Purpose  Set low power mode Parameters  n=0: Inactivate (Default) n=1: Activate Description  During no data transmission, Parani-SD can be in low power mode to save the power. It takes a few seconds to wake the Parani-SD out of low power mode.  A.3.30. AT+BTRSSI,n (Single Connection Mode Only)  Response  OK 0,255,0,0 (repeatedly) Purpose  Test signal strength Parameters  n=0: Stop signal strength test n=1: Start signal strength test Description  When Bluetooth connection is established, you can use this command in Standby status. The signal strength will be displayed repeatedly in order of Status, LinkQuality, Status, RSSI. If the LinkQuality is close to 255 and RSSI is close to 0, the signal strength is in good standing. Example  +++ AT+BTRSSI,1 OK 0,255,0,0  A.3.31. AT&V  Response  S0:m0;S1:m1;  …Sn:mn OK Purpose  Display all the S-registers
 38Description  All parameters are stored at S-register in flash memory. These values are sustained until hardware reset.  A.3.32. ATSnn?   Response  value OK Purpose  Display a given S-register Parameters  nn= Address of S-register Description  A specific S-register will be displayed.  A.3.33. ATSnn=mm  Response  OK Purpose  Change S-register value Parameters  nn= Address of S-register mm= New value of S-register Description  Some S-registers are optimized for the overall performance and protected and cannot be changed. When users try to change these S-registers, response is ‘ERROR’. For details of S-register, refer Appendix. B. Example  ATS10=0    A.4. Command Validity  Operation Status AT Command  Standby Pending Connect AT  ○ ○  ATZ  ○ ○  AT&F  ○ ○  AT+BINQ?  ◎   ATD112233445566  ◎   ATD  ◎   AT+BTSCAN  ◎   AT+BTSCAN,n,to  ◎   AT+BTSCAN112233445566,to  ◎   AT+BTCANCEL  ○  +++   ○ AT+SETESC  ◎   ATO  ●   ATH  ●
 39AT+BTSEC,Auth,Encr  ◎   AT+BTLAST?  ○ ○  AT+BTMODEn  ◎   AT+BTNAME=”Name”  ◎   AT+BTKEY=”nnnn”  ◎   AT+BTINFO?  ○   AT+BTLPM,n  ◎   AT+BTSD?  ○ ○  AT+BTCSD  ◎   AT+BTFP,n  ◎   AT+UARTCONFIG,b,p,s  ◎   AT+USEDIP?  ○ ○  AT+BTVER?  ○ ○  AT+BTRSSI,n  ●    ◎  Valid only when Parani-SD is not connected to other Bluetooth device. ●  Valid only when Parani-SD is connected to other Bluetooth device.
 40Appendix B: S-Register   S-registers contain 52 parameters for the Parani-SD Series. These are stored in flash memory and the values will be saved unless hardware reset is executed. The value of S-register can be accessed and changed with ATS command. Some S-registers not shown below are set to maximize the performance of Parani-SD Series. Thus it is not recommended to change these S-registers. Changing the values of S-register can only be done in the Standby mode. Turn Parani-SD off and on.  B.1. S1: Force to Reconnect (default 1)  S1=0, Parani-SD in Mode1 does not try to reconnect when disconnected. S1=1, Parani-SD in Mode1 keeps trying to reconnect when disconnected.  B.2. S3: Stream UART Policy (default 0)  S3=0, the priority of UART streaming is throughput. S3=1, the priority is latency, which minimizes the delay of data transmission. This is useful in case of transmitting very small data quickly. When this value is 1, in order to minimize latency, Parani-SD sends the received data immediately. When this value is 0, the Parani-SD maximizes throughput, the Parani-SD stores received data for a short time and sends a large data packet. If the packet length is less than 100 bytes, having latency being the priority is recommended. If the packet length is more than 100 bytes, having throughput as the priority is recommended. Also, if you want to use high baud rate, throughput priority will be more effective. Just for reference, the buffer length for receiving data is 2 Kbytes.    B.3. S4: Enable Remote Name Query (default 1)  S4=0, Parani-SD will query only the BD address. This speeds up the inquiry process. S4=1, Parani-SD will query the BD address, device name and class of device. When this value is 1, Parani-SD finds not only BD address but also friendly name. When this value is 0, Parani-SD finds only BD address. When set to 0 this will make queries much faster. When using the pairing button, finding friendly name will be omitted automatically.  B.4. S6: Enable Low Power Mode (default 0) S6=0, deactivate Low Power Mode. S6=1, activate Low Power Mode. This value decides whether Parani-SD works in Low Power Mode or not. When this value is 0, Parani-SD works only in active power mode. When Parani-SD works in Low Power mode, delay in transferring data may occur.    B.5. S10: Enable Response Message (default 1)  S10=0, Parani-SD does not send response messages to the host system. S10=1, Parani-SD sends response messages to host system. This value decides whether Parani-SD sends response messages such as OK, ERROR, CONNECT, DISCONNECT or not. When this value is 0, Parani-SD will not send any response messages. If the response messages conflicts with your host programs or devices that is connected to Parani-SD, change this value to 0.  B.6. S11: Enable Escape (default 1)  S11=0, Parani-SD does not allow escape sequence characters. The operation status of Connect cannot be changed to Standby. Since the Parani-SD skips the process of detecting escape sequence characters, more efficient data transmission can be had.
 41S11=1, Parani-SD allows for the escape sequence character. Whenever it is needed, the Connect status can be changed to Standby.  B.7. S12: Clear Data Buffer When Disconnected (default 1)  S12=0, Parani-SD does not clear the data buffer received from host system when disconnected. S12=1, Parani-SD clears the data buffer when disconnected.  B.8. S13: Enable DCD Signal (default 1)  S13=0, DCD signal off S13=1, DCD signal on  B.9. S14: Enable DTR Transfer (default 1)  S14=0, DTR/DSR signal is transferred in a loop-back fashion. S14=1, DTR signal is transferred to DSR of remote device.  B.10. S15: Enable Disconnect by DTR (default 0)  S15=0, DTR signal cannot release the connection. S15=1, The Bluetooth connection can be released when DTR signal is off. This value decides whether Bluetooth connection is released when DTR signal drops or not. If this value is 1, you can use DTR signal in order to disconnect Bluetooth connection.   B.11. S22: Faster Connection (default 0)  S22=0, none S22=1, page scan S22=2, inquiry scan S22=3, page/inquiry scan Connecting time is average 1.5sec faster than normal mode.  B.12. S23: Intercharacter Timeout Setting (default 0)  S23=0 : Not used S23=1 : 1 x S26 S23=2 : 10 x S26 S23=3 : 100 x S26  B.13. S24: Maximum Number of Inquiry Result (default 15)  The maximum number of inquiry list can be controlled. This value is up to 15.  B.14. S26: Intercharacter Timeout (default 0)  This value describes time interval between characters used to separate the data from serial port. If there is no more data coming from serial port in this value, data is sent to client.  S23=1 x S26=50 : Timeout-> 50msec S23=2 x S26=50 : Timeout-> 500msec S23=3 x S26=3 : Timeout-> 300msec
 42       * When 10 bytes data are sent every intercharacter timeout, they are sent separately by 10 bytes at the optimal value. If the intercharater timeout is set below the optimal value, the date will be put together and sent by 20, 30, 40 bytes or more.  B.15. S28: Escape Sequence Character (default 43)  The decimal number of the ASCII code of escape sequence character can be controlled. The initial value is 43, the ASCII code of ‘+’.  B.16. S31: Page Timeout (default 20)  This is the timeout in seconds to attempt connection with the ATD command. After this timeout expires, the Parani-SD will restart automatically. If this value is 0, Parani-SD will attempt to connect without restarting  B.17. S33: Inquiry Timeout (default 30)  This is the timeout in seconds to execute inquiry scan.  B.18. S37: Supervision Timeout (default 5)  This is the timeout to presume disconnection, which is set to 5 seconds initially. The smaller the value becomes, the more quickly Parani-SD can detect an abnormal disconnection. But when the communication is suspended, it may be regarded as disconnection. This value should be greater than the Slave Disconnect Timeout(S57). (Slave unit depends on the value of master unit.)  B.19. S43: COD (default 001F00)  This value describes the sort of the bluetooth device and is editable.  B.20. S44: COD Filter (default 0)  This value is used to filter the sort of the bluetooth devices on inquiring. All the bluetooth devices are inquired in case of 0. In case of 3E0100, bluetooth devices with COD 3E0100 are inquired.  B.21. S45: Inquiry Access Code (default 0x9E8B33)  Inquiry access code is used during inquiry state. The reserved IAC addresses are 0x9E8B00 ~ 0x9E8B3F. The general inquiry IAC is 0x9E8B33. Parani-SD is able to find the Bluetooth devices that are configured as the same IAC  B.22. S46: BD Address of Last Connected Device  This saves the BD address of the Bluetooth device connected most recently in single connection mode. This saves the Task1 BD address of the Bluetooth device connected most recently in a multiple connection mode.  Intercharacter Timeout  * Optimal Value(S23 x S26) 50ms 180 100ms 235 200ms 340
 43B.23. S48: Low Power Max Interval (default 5000)  This is the max interval value to use low power mode, which is set to 5000 initially. (5000 x 625μsec = 3125msec)  B.24. S49: Low Power Min Interval (default 4500)  This is the min interval value to use low power mode, which is set to 4500 initially. (4500 x 625μsec = 2812msec) A small interval increases power consumption, a large interval increases latency.  B.25. S52: Low Power Timeout (default 5)  This is the low power timeout value, which is set to 5 initially. (5sec) During no data transmission in the timeout, Parani-SD will be in low power mode to save the power. Therefore, it takes a few seconds to wake the Parani-SD out of low power mode.  B.26. S54: BD Address of Last Connected Device  This saves the Task2 BD address of the Bluetooth device connected most recently in a multiple connection mode.  B.27. S55: BD Address of Last Connected Device  This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple connection mode.  B.28. S56: BD Address of Last Connected Device  This saves the Task4 BD address of the Bluetooth device connected most recently in a multiple connection mode.  B.29. S57: Slave Disconnect Timeout (default 3)  This S57 register value defines the time period in seconds that a master unit waits in case a slave unit does not receive the data sent from the master. For this time period, the master unit will not send data to all slave units if any slave unit does not receive the data. If the slave unit does not receive the data after this time period elapses, the master unit will disconnect the connection with the problematic slave unit. The value should be greater than 0 and smaller than the Supervision Timeout(S37).  B.30. S58: MAX TX POWER (default 0)  This value describes the peak output power. Setting this causes rebooting and applying. (There can be a little deviation depending on the each device.) Parameter dBm 0  Use chip setting. 1 -12 2 -8 3 -4 4 0 5 4 6 8 7 12 8 16
 44B.31. S59: Current Slave in Communication (default 0)  This value shows the current slave number in communication. The value is automatically stored when the slave is selected for communication. This value can also be set by user so the master unit connects to a specific slave to connect first in case the master unit reboots. The value range is 0~4. 0 means the maser unit never connected to a slave. The master will connect to a slave whatever responses first.    B.32. S60: Reconnect Time Interval (default 5)    This value defines reconnect time interval in case a slave is disconnected in multiple connection mode. The actual reconnect time interval will be the value multiplied by two in seconds. For example, if the value is set to 5, the reconnect time interval will be 10 seconds. The value should be greater than or equal to 5. The master unit will only try to reconnect when its mode is set to Mode1.
 45Appendix C: Trouble Shooting   C.1. Data Loss or Malfunctioning   C.1.1. Response Message  AT response messages from the Parani-SD may affect the host system unexpectedly. Do not use Parani-SD If your applications cannot allow for this wireless time delay.  C.2. Transmission Delay  C.2.1. RF Processing Delay  It takes 30msec approximately for a Parani-SD to complete a data transmission to the other Bluetooth device. This time delay cannot be reduced and may enlarge as the RF transmission environment becomes worse. Do not use Parani-SD If your applications cannot allow for this time delay.  C.2.2. RF Transmission Environment  If there are many Bluetooth devices working in a small area and/or the RF communication distance is too great and/or there are some obstacles affecting RF performance, the Parani-SD repeats the transmission packet by packet due to interferences and/or low RF performance. This may lead to increased data transmission time delays.
 46
 47Appendix D: Warranty   D.1. GENERAL WARRANTY POLICY  Sena Technologies, Inc. (hereinafter referred to as SENA) warrants that the Product shall conform to and perform in accordance with published technical specifications and the accompanying written materials, and shall be free of defects in materials and workmanship, for the period of time herein indicated, such warranty period commencing upon receipt of the Product.   This warranty is limited to the repair and/or replacement, at SENA’s discretion, of defective or non-conforming Product, and SENA shall not be responsible for the failure of the Product to perform specified functions, or any other non- conformance caused by or attributable to: (a) any misapplication or misuse of the Product; (b) failure of Customer to adhere to any of SENA’s specifications or instructions; (c) neglect of, abuse of, or accident to, the Product; or (d) any associated or complementary equipment or software not furnished by SENA.   Limited warranty service may be obtained by delivering the Product to SENA or to the international distributor it was purchased through and providing proof of purchase or receipt date. Customer agrees to insure the Product or assume the risk of loss or damage in transit, to prepay shipping charges to SENA, and to use the original shipping container or equivalent.     D.2. LIMITATION OF LIABILITY  EXCEPT AS EXPRESSLY PROVIDED HEREIN, SENA MAKES NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY EQUIPMENT, PARTS OR SERVICES PROVIDED PURSUANT TO THIS AGREEMENT, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NEITHER SENA NOR ITS DEALER SHALL BE LIABLE FOR ANY OTHER DAMAGES, INCLUDING BUT NOT LIMITED TO DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER IN AN ACTION IN CONTRACT OR TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY), SUCH AS, BUT NOT LIMITED TO, LOSS OF ANTICIPATED PROFITS OR BENEFITS RESULTING FROM, OR ARISING OUT OF, OR IN CONNECTION WITH THE USE OF FURNISHING OF EQUIPMENT, PARTS OR SERVICES HEREUNDER OR THE PERFORMANCE, USE OR INABILITY TO USE THE SAME, EVEN IF SENA OR ITS DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL SENA OR ITS DEALERS TOTAL LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT.   D.3. HARDWARE PRODUCT WARRANTY DETAILS  WARRANTY PERIOD: SENA warranties embedded hardware Product for a period of one (1) year, and external hardware Product for a period of three (3) or five (5) years according to the Product type. WARRANTY PROCEDURE: Upon return of the hardware Product SENA will, at its option, repair or replace Product at no additional charge, freight prepaid, except as set forth below. Repair parts and replacement Product will be furnished on an exchange basis and will be either reconditioned or new. All replaced Product and parts become the property of SENA. If SENA determines that the Product is not under warranty, it will, at the Customers option, repair the Product using current SENA standard rates for parts and labor, and return the Product at no charge in or out of warranty.   WARRANTY EXCLUSIONS: Damages caused by - Accidents, falls, objects striking the SENA product, - Operating the Product in environments that exceed SENA's temperature and humidity specifications, - Power fluctuations, high voltage discharges, - Improper grounding, incorrect cabling, - Misuse, negligence by the customer or any other third party, - Failure to install or operate the product (s) in accordance to their SENA User Manual, - Failure caused by improper or inadequate maintenance by the customer or any other third party,
 48- Floods, lightning, earthquakes, - Water spills, - Replacement of parts due to normal wear and tear, - Hardware has been altered in any way, - Product that has been exposed to repair attempts by a third party without SENA’s written consent, - Hardware hosting modified SENA Software, or non-SENA Software, unless modifications have been approved by SENA. - Battery component capacity degradation due to usage, aging, and with some chemistry, lack of maintenance.    D.4. SOFTWARE PRODUCT WARRANTY DETAILS  WARRANTY PERIOD: SENA warranties software Product for a period of one (1) year.   WARRANTY COVERAGE: SENA warranty will be limited to providing a software bug fix or a software patch, at a reasonable time after the user notifies SENA of software non-conformance.   D.5. THIRD-PARTY SOFTWARE PRODUCT WARRANTY DETAILS  The warranty policy of the third-party software is conformed to the policy of the corresponding vendor