T310c Access Point Quick Setup GuideNOTE: The minimum software revision for the T310c isZoneDirector (ZD) 10.1 or later, or SmartZone (SZ) 3.6 orlater, or standalone AP firmware 108.0 or later.This Quick Setup Guide provides step-by-step instructions onhow to field-install the Ruckus Wireless T310c access point(AP). For detailed information on planning the installation,performing a site survey, and operating the T310c, refer to theRuckus Wireless Outdoor Access Point User Guide, availableat https://support.ruckuswireless.com.WARNING! Only trained and qualified personnel should beallowed to install, replace, or service this equipment.WARNING! Installation of this equipment must comply withlocal and national electrical codes.CAUTION! Make sure that you form a 80mm - 130mm(3”-5”) drip loop in any cable that is attached to the AP orthe building. This will prevent water from running along thecable and entering the AP or the building where the cableterminates.CAUTION! Be sure that grounding is available and that itmeets local and national electrical codes. For additionallightning protection, use lightning rods and lightningarrestors.CAUTION! Make sure that proper lightning surge protectionprecautions are taken according to local electrical code.WARNING! Ruckus Wireless strongly recommends that youwear eye protection before mounting the T310c.This Guide in Other Languages• 请从以下网站请得请指南的请体中文版 https://support.ruckuswireless.com.• Vous trouverez la version française de ce guide à l'adressesuivante https://support.ruckuswireless.com.•このガイドの日本語版は https://support.ruckuswireless.com でご覧ください。•이 가이드의 한국어 버전은 웹 사이트 (https://support.ruckuswireless.com) 에서 확인하시기 바랍니다.• Veja a versão em português (Brasil) deste guia em https://support.ruckuswireless.com.• Puede ver la versión en español (América Latina) de estaguía en https://support.ruckuswireless.com.Before You BeginBefore deploying Ruckus Wireless products, please check forthe latest software and the release documentation.• Release Notes and other user documentation are availableat http://support.ruckuswireless.com/documents.• Software upgrades are available at http://support.ruckuswireless.com/software.• Open source information is available at http://opensource.ruckuswireless.com.• Software license and limited warranty information areavailable at http://support.ruckuswireless.com/warranty.Before deploying your Ruckus Wireless Access Point, verifythat all items listed in Package Contents are included in thepackage. If any item is damaged or missing, notify yourauthorized Ruckus Wireless sales representative. Also,make sure that you have the required hardware and tools.Required Hardware and Tools• No. 2 Phillips screwdriver• Small flat-blade screwdriver• Torque wrench or torque screwdriver with sockets• Long-nose pliers• Electrical wire stripping and terminal crimping pliers• Pipe or pole --OR-- a sturdy flat surface• Electric drill with drill bits and customer-supplied wallanchors, flat washers, and hex nuts for flat-surface mountPackage ContentsA complete T310c field installation package includes all of theitems listed below (see Figure below for illustrations):• T310c Access Point (A)• M25 data cable gland (B)• Ground wire with lug (C)• Pole/Wall Mount Bracket Kit (D)• Four steel pipe clamps• Service Level Agreement/Limited Warranty Statement• Declaration of Conformity• Regulatory Statement• Ruckus Wireless AP Getting Started Guide• This Quick Setup GuideFIGURE 1  T310c Package ContentsMounting InstructionsConnecting And Sealing the RJ-45 CablesConnect and seal the RJ-45 cable(s) using the M25 datacable glands shown in the Figure below.WARNING! Do not use any PoE injector not tested andapproved by Ruckus Wireless to power the T310c AccessPoint.FIGURE 2  T310c LEDs and Ports1. Feed the end of the cable through the sealing nut, rubberO-ring, clamping ring assembly and cable gland base asshown.NOTE: Do not seat the clamping ring and rubber O-ringinto the gland body until the gland body has beentorqued to spec.Copyright ® 2017 Ruckus Wireless, Inc. Page 1 of 3Published September 2017, Part Number 800-71622-001 Rev A
FIGURE 3  RJ-45 cable and cable gland assembly2. Use a wide flat-blade screwdriver to remove the required(PoE IN) blanking cap from the AP.3. Connect the cable to the Ethernet port on the AP.4. Tighten the cable gland base into the AP chassis to 7 N.mor 62 in-lbs.5. Wrap the clamping ring assembly around the rubber O-ring. Make sure that the clamping ring assembly fullyencloses the rubber O-ring.6. Seat the clamping ring assembly and rubber O-ring in thecable gland base.7. Hand-tighten the sealing nut.Attaching the Mounting Bracket To A FlatSurface1. The AP mounting bracket attaches to the AP using acaptive screw. Use a medium flat-blade or No. 2 Phillipsscrewdriver to loosen the captive screw (A in the Figurebelow) and pull up on the end of the bracket to removethe bracket from the AP (B in the Figure below).FIGURE 4  Removing the mounting bracket2. Using either of the two options shown in Figure 5, holdthe mounting bracket at the location on the mountingsurface where you want to mount the AP. Use the holeson the mounting bracket as a template to mark thelocations of the mounting holes.NOTE: The mounting bracket can be mounted to avertical or horizontal surface to support the AP in therequired orientation.FIGURE 5  Mounting bracket on a flat surface3. Remove the mounting bracket from the mounting surface.4. Drill holes required for the customer-supplied mountinghardware.5. Attach the mounting bracket to the flat surface using themounting hardware.6. Using the mounting hardware instructions, tighten thehardware to secure the mounting bracket.7. Continue with Mounting the AP.Attaching the Mounting Bracket to a Pole1. The AP mounting bracket attaches to the AP using acaptive screw. Loosen the screw (A in Figure 4) and pullup on the end of the bracket to remove the bracket fromthe AP (B in the Figure above).2. Insert the open end of one steel clamp (D in the Figureabove) into two of the slots on the mounting bracket.NOTE: The mounting bracket can be mounted to avertical or horizontal pole to support the AP in therequired orientation.3. Using either of the two options shown, use the clamp(s) toattach the mounting bracket to the pole. Tighten theclamps to 3 N.m or 27 in-lbs, or per manufacturer’sspecifications if the factory-supplied clamps are not used.4. If necessary, daisy-chain the other steel clamps toaccommodate larger poles.FIGURE 6  Mounting bracket on a pole5. Continue with Mounting the AP.Mounting the AP1. Snap the AP back onto the mounting bracket (A in theFigure below), and use a medium flat-blade or No. 2Phillips screwdriver to tighten the captive screw to 1.1N.m or 10 in-lbs to secure the bracket to the AP (B).FIGURE 7  Attaching the mounting bracket to the AP2. Optional Step: If you also need to lock the mountingbracket to the AP, then use a matching securityscrewdriver to screw the customer-supplied lockingstainless steel 6mm M3 panhead security screw throughthe mounting bracket and into the AP chassis.CAUTION! Make sure that the customer-suppliedlocking stainless steel M3 panhead security screw is nolonger than 6mm. If the security screw is longer than6mm, it can damage the AP chassis.Copyright ® 2017 Ruckus Wireless, Inc. Page 2 of 3Published September 2017, Part Number 800-71622-001 Rev A
FIGURE 8  Locking the mounting bracket to the APYou have completed mounting the AP to the mountingbracket.Earth Grounding the APCAUTION! Make sure that earth grounding is available andthat it meets local and national electrical codes. Foradditional lightning protection, use lightning rods andlightning arrestors.NOTE: The color coding of ground wires varies by region.Before completing this step, check your local wiringstandards for guidance.Using the factory-supplied ground wire and ground screw/washer set, connect a good earth ground to the AP chassisground point.CAUTION! The T310c AP includes one 9mm stainless steelM6x1 earth ground screw with split lock and flat washers.Make sure that any replacement screw is no longer than9mm. If a screw is longer than 9mm, it can damage the APchassis.FIGURE 9  Connect good earth ground to AP hereCongratulations! You have mounted your T310c access point.TroubleshootingCAUTION! If required, you can reset the AP to its factorydefault settings by pressing the reset button located insidethe PoE IN port. DO NOT DO THIS UNLESS SOINSTRUCTED. (Doing this resets the AP IP address to192.168.0.1.)NOTE: After a reset, you can access the internal AP webinterface using https://192.168.0.1. Your device must useany other address from 192.168.0.2 through192.168.0.254, with subnet mask 255.255.255.0. Theusername is super, and the password is sp-admin. Refer tothe Outdoor Access Point User Guide for information onconfiguring and operating the AP. This document isavailable at https://support.ruckuswireless.com.For More InformationFor information on how to configure and manage the AP, referto the Ruckus Wireless Outdoor Access Point User Guide,available from https://support.ruckuswireless.com.Copyright ® 2017 Ruckus Wireless, Inc. Page 3 of 3Published September 2017, Part Number 800-71622-001 Rev A

Navigation menu