                        Copyright © 2018 by Rosslare. All rights reserved.  This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE. ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.  TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS. The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE. ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents  iii Table of Contents 1. Introduction ....................................................................... 7 1.1 Installation Kit ..................................................................................... 7 2. Technical Specifications ................................................... 8 3. Mounting ........................................................................... 9 3.1 General .............................................................................................. 9 3.1.1 1-Shaped Stand Bracket Side-Loaded ........................................................... 9 3.1.2 L-Shaped Stand Bracket Top-Loaded .......................................................... 10 3.1.3 Adjusting the Azimuth Angle of Antenna ................................................... 11 4. Wiring ............................................................................... 12 5. Operation Instructions ................................................... 14 6. APP-x421 Admin App ...................................................... 15 6.1 Opening the App .............................................................................. 15 6.2 Reader Settings ................................................................................. 16 6.3 AY-U920BT Reader Configuration Settings ........................................ 17 6.4 Additional Settings ........................................................................... 18 A. Declaration of Conformity ............................................. 19 B. Radio Equipment Directive (RED) .................................. 20 C. RoHS Directive ................................................................. 21 D. Limited Warranty ............................................................ 22 AY-U920BT-US Installation and User Manual
List of Figures iv   List of Figures Figure 1: 1-shaped Stand Bracket Side-Loaded ................................................ 9 Figure 2: L-shaped Stand Bracket Loaded...................................................... 10 Figure 3: Antenna Angle Side View .............................................................. 11 Figure 4: Antenna Angle Top View ............................................................... 11 Figure 5: Wiring Colors................................................................................. 12 AY-U920BT-US Installation and User Manual
List of Tables   v List of Tables Table 1: Wiring the Unit as a Reader to a Control Panel ................................ 12  AY-U920BT-US Installation and User Manual
Notice and Disclaimer vi   Notice and Disclaimer This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein. BEFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES.  The system must not be used for purposes other than those for which it was designed.  The use of the software associated with the system and/or product, if applicable, is subject to the terms of the license provided as part of the purchase documents.  ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document.  This manual describes the maximum configuration of the system with the maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.   Incorrect operation or installation, or failure of the user to effectively maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.  The text, images and graphics contained in the manual are for the purpose of illustration and reference only.  All data contained herein subject to change without prior notice.  In no event shall manufacturer be liable for any special, direct, indirect, incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).  All wiring diagrams are intended for reference only, the photograph or graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).AY-U920BT-US Installation and User Manual
Introduction   7 1. Introduction The AY-U920BT is a UHF and Bluetooth reader that is available with versions in both UHF frequencies (865-868 and 902-928 MHz) and supports Bluetooth BLE frequencies and protocols. Two associated apps for iOS and Android smartphones made by Rosslare can be used with the reader – BLE-ID credential app and BLE-Admin configuration app – for programming operational settings. The reader is waterproof (IP65) and is suitable for use in a wide range of RFID applications, such as transport management, vehicle management, car parking, production process control, and access control. The reader supports the following functions:  Reading UHF hard credential  Reading BLE soft credential  Transmitting credential ID to the controller  Acting based on controller’s input (allowing access or not)  Self-update  Reconfiguration provided by credential (soft or hard) or by PC SW The AY-U920BT series includes the following models:  AY-U920BT-US: 902–928 MHz (America)  AY-U920BT-EU: 865–868 MHz (Europe) 1.1 Installation Kit The AY-U920BT package includes:  1 AY-U920BT reader with a 5 m (16.4 ft) 10-wire cable                 1 installation bracket kit  1 installation and user manual  AY-U920BT-US Installation and User Manual
Technical Specifications 8   2. Technical Specifications Electrical Characteristics Operating Voltage Range Typical: 9 to 12 VDC (2 A) Max: 24 VDC  Input Current Standby: 0.2 A max Read: 1.2 A max Credential Read Distance*  0.5 to 12 m (1.6 to 39.4 ft) (adjustable) Transmission Protocol Wiegand 26-Bit (default) Wiegand 32-Bit Wiegand 34-Bit Wiegand 40-Bit Wiegand 56-Bit Wiegand 64-Bit OSDP Custom Maximum Cable Distance  150 m (492 ft) with 18” AWG cable Frequency AY-U920BT-US: 902–928 MHz (America) AY-U920BT-EU: 865–868 MHz (Europe) Modulation Type ASK Read Sensitivity Dual polarization read mode Cards and Tags • EPC GEN2 (ISO18000-6C) Tags • BLE-ID soft credentials * Measured using a Rosslare proximity card or equivalent. Environmental Characteristics Operating Temp. Range -20°C to 60°C (-4°F to 140°F) Operating Humidity Range 0 to 95% (non-condensing) Suitable for outdoor use (IP 54) Physical Characteristics Height x Width x Depth 36.5 x 36.5 x 3.2 cm (14.4 x 14.4 x 1.3 in.) Weight 2.8 kg (6.2 lb)  AY-U920BT-US Installation and User Manual
Mounting   9 3. Mounting  Installing an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader. 3.1 General There are two methods that can be used when installing the reader.  1-Shaped Stand Bracket Side-Loaded  L-Shaped Stand Bracket Top-Loaded Each installation method is selected based on application requirements and actual location. 3.1.1 1-Shaped Stand Bracket Side-Loaded In this method, the stand pole should have a diameter of between 50 and 60 mm (2 to 2.4 in.) and a height of 2.2 m. The pole should be made of stainless steel with a thickness of at least 1.2 mm (0.05 in.). Use the bracket contained in the package box to mount the AY-U920BT reader to the top of the stand pole depending on actual vehicle type (mainly large car and small car) (Figure 1). Figure 1: 1-shaped Stand Bracket Side-Loaded  Adjust the height from the center of AY-U920BT reader to lane level to be around 2.0 m (6.5 ft). AY-U920BT-US Installation and User Manual
Mounting 10   3.1.2 L-Shaped Stand Bracket Top-Loaded In this method, the L-shaped stand pole should have a diameter of between 60 to 80 mm (2.4 to 3.1 in.) and a height of 4.2 m (13.8 ft). The pole should be made of stainless steel with the thickness of at least 1.2 mm (0.05 in.). Use the bracket contained in package box to mount the AY-U920BT reader to the rail near the center of the lane (Figure 2). Figure 2: L-shaped Stand Bracket Loaded  Adjust the height between the rail and the ground to between 3.5 to 4.0 m (11.5 to 13 ft), depending on the height of vehicle. AY-U920BT-US Installation and User Manual
Mounting AY-U920BT-US Installation and User Manual 11 3.1.3 Adjusting the Azimuth Angle of Antenna The angle of inclination with the ground plane of the antenna should be approximately 60° to 75° (Figure 3), while the deviation angle of the antenna should be biased towards the lane direction (Figure 4). Figure 3: Antenna Angle Side View  Figure 4: Antenna Angle Top View
Wiring 12  AY-U920BT-US Installation and User Manual 4. Wiring The units are supplied with a 5 m (16.4 ft) 10-conductor pigtail with exposed wires coated with solder (see Figure 5). Figure 5: Wiring Colors  To connect the unit as a reader to an access control unit: 1. Select the appropriate connections according to Table 1. 2. Prepare the controller cable by cutting its jacket back about 3 cm (1¼") and strip the insulation from the wires about 1.3 cm (½"). 3. Splice the reader’s pigtail wires to the corresponding controller wires and cover each joint with insulating tape. Table 1: Wiring the Unit as a Reader to a Control Panel Wire Color  Output Red Power Black Ground Green Data 0 / Data / C2 White Data 1 / Clock / C1 Orange Green LED Control Brown Yellow LED Control Purple OC Output* Yellow Hold/Trigger Control Blue RS-485 - A / OSDP** Gray RS-485 - B / OSDP** *  for future use ** RS-485 is used for firmware update.
Wiring AY-U920BT-US Installation and User Manual 13 4. Trim and insulate the ends of all unused conductors individually. Do not short any unused wires together.  • The individual wires from the reader are color coded according the Wiegand standard. • When using a separate power supply for the reader, this supply and that of the controller must have a common ground. • The reader’s cable shield wire should be preferably attached to an earth ground, or a signal ground connection at the panel, or the power supply end of the cable. This configuration is best for shielding the reader cable from external interference.
Operation Instructions 14  AY-U920BT-US Installation and User Manual 5. Operation Instructions After wiring the unit to a controller (POWER, GND, D0, D1), you should test the reader. To test the reader: 1. Power up the reader. One beep is emitted and then it begins an auto-calibration procedure. After 2 seconds, the reader enters working mode. 2. Present the appropriate type of credential to the reader. A short beep is emitted, indicating that the credential is read properly.
APP-x421 Admin App AY-U920BT-US Installation and User Manual 15 6. APP-x421 Admin App The settings for the AY-U920BT reader can be configured using Rosslare’s APP-x421 Admin app. 6.1 Opening the App Download the APP-x421 Admin app for the AY-U920BT reader from Google Play or the Apple Store, depending on the model of your mobile device.  An Android device should be v5.0 and above and an iOS device should be v8.0 and above. All relevant readers are displayed.
APP-x421 Admin App 16  AY-U920BT-US Installation and User Manual 6.2 Reader Settings Tap the ID of the reader you wish to configure.  You are asked to enter your password. The default password upon initial use is 12345678.  The Reader Settings screen opens.   Displays the reader’s type and MAC address Tap to rename the reader Tap to edit your password (must be 8 digits) Tap to update the firmware Tap to make the reader beep so you can identify it Tap to view/edit configuration Tap to send the device ID to the reader to test access
APP-x421 Admin App AY-U920BT-US Installation and User Manual 17 6.3  Set the configuration settings as described below.  LED Activities – Enable or disable LED activation BLE Functionality – Enable or disable BLE communication UHF Functionality – Enable or disable UHF communication Regulation – Select the transmitting frequency Tag Type – Select the tag type you wish to read with the reader Transition Power – Slide to select the signal power Transmission Protocol – Select the protocol Transmission Protocol Type – Select number of bits Tag Mode – Select if reading one tag or multiple tags  Output Interval – Slide to select the interval of sending a credential from the reader OSDP Address – Slide to select the address of the reader  Timing Interval – Enter the time between reads Starting Address – Slide to select the initial ID bit Read Mode – Select the read mode Read Trigger – Slide to select the amount of time between reading of credentials in the surrounding AY-U920BT-US Reader Configuration SettingsAY-U920BT-US Reader Configuration SettingsAY-U920BT-US Reader Configuration Settings
APP-x421 Admin App 18  AY-U920BT-US Installation and User Manual 6.4 Additional Settings If you tap on the 3 lines on the main screen, additional options are available.         Tap to display the BLE soft credential Tap to:  Set the reader’s read range  Change the GUI language  Set the automation, which allows the reader to support self checkups in specific chosen intervals Tap to see the EULA
Declaration of Conformity     19 A. Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  This device may not cause harmful interference.  This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.  AY-U920BT-US Installation and User ManualFCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled   environment . This transmitter must not be co-located or operating in conjunction with any other antenna   or transmitter. This equipment should be installed and operated with minimum distance 25cm between the   radiator &you body.
Radio Equipment Directive (RED) 20  AY-U920BT-US Installation and User Manual B. Radio Equipment Directive (RED) Under our sole responsibility that the following labeled AY-U920BT is tested to conform to the EU Radio Equipment Directive – RED 2014/53/EU – in electrical and electronic equipment.
RoHS Directive AY-U920BT-US Installation and User Manual 21 C. RoHS Directive Under our sole responsibility that the following labeled AY-U920BT is tested to conform to the Restriction of Hazardous Substances (RoHS) directive – 2011/65/EU – in electrical and electronic equipment
Limited Warranty 22  AY-U920BT-US Installation and User Manual D. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
 AY-U920BT-US 0706-0960663+00     Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630  Fax: +852 2795-1508  support.apac@rosslaresecurity.com  United States and Canada  Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax:    +1-817-305-0069 support.na@rosslaresecurity.com  Europe Rosslare Israel Ltd. 22 Ha'Melacha St., P.O.B. 11407 Rosh HaAyin, Israel Tel: +972 3 938-6838 Fax: +972 3 938-6830 support.eu@rosslaresecurity.com Latin America Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com  China Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel:  +86 755 8610 6842 Fax:  +86 755 8610 6101 support.cn@rosslaresecurity.com  India Rosslare Electronics India Pvt Ltd. Tel/Fax: +91 20 40147830 Mobile: +91 9975768824 sales.in@rosslaresecurity.com                   CERTISO  9001ISO  14001