Resmed Sensor Technologies BM04 SleepMinder User Manual Manual

Resmed Sensor Technologies Ltd SleepMinder Manual

Manual

     SleepMinderTM Non Contact Sleep Monitoring
ABOUT THE SLEEPMINDERTM  The SleepMinderTM uses a specially-designed motion sensor to detect body movement associated with sleeping. It can be used in the home, hospital or clinical setting.   USING THE SLEEPMINDERTM   1 SleepMinderTM uses a removable standard Secure Digital (SD) memory card to store the data. Make sure the memory card is inserted in the slot and that the 'LOCK' tab on the SD card is set at unlocked. Push the SD card into the slot until you hear a click. If the card is flush with the casing, it is inserted correctly.  2 Insert the power connector from the 12V DC adaptor and turn it on at AC wall outlet. There is no power switch on the unit.  3 The small light on the rear will show green. There should be a single beep. This indicates that the unit is powered.  4 Put the SleepMinderTM on your side of the bed, at about an arm's length – 3ft (90cm) – from your chest. It is important that the front of the SleepMinderTM (indicated by the BiancaMed logo) is facing toward your chest as shown in the figure below.  5 Do not switch off the SleepMinderTM until you have finished the study – even if the study runs over a number of nights.          • The base of the SleepMinderTM should be above the mattress, and up to a max 8” (20cm) higher.   • The green light should face away from you.    • Place at approximately an arm's length from you (or 3ft [90cm])  Warning • If SleepMinderTM is setup contrary to the operating conditions above it may produce misleading results.
SCHEDULES The unit that you have been given may be set to start & stop automatically at particular times. A typical setup is that the unit will record between the hours of 9pm and 9am only, with the time set to your local time zone.    When it is logging, you will see a green light constantly lit on the rear. If the green light flashes, the unit is not logging. All recorded data is saved on the memory card indefinitely. It can store over 1 year of data.  TROUBLESHOOTING When I insert the memory card and power the device, the red light stays on or the red light flashes or the unit beeps three times. • This is a problem with the memory card. Power down the unit and wait 2 seconds. Push the memory card to release. Check the 'LOCK' tab on the memory card to make sure it is unlocked. Re-insert the memory card, pushing firmly until you hear a click.    When I plug in the power cord, there is no green light on the SleepMinderTM at all. • This is a power problem. Check the AC wall outlet, and check the power adaptor (black unit) is showing a green light.  For further support, please phone BiancaMed on +353 1716 3755 or email help@biancamed.com.  BiancaMed Limited, NovaUCD, Belfield Innovation Park, Belfield, Dublin 4, Ireland.  Warnings • Never remove the SD-card while the unit is powered. If it is ever necessary to remove the SD-card, the unit must be powered down for 2 seconds before removal. • Do not use in close proximity (i.e., closer than 1 ft [30cm]) to wireless routers, laptops, mobile phones (especially do not put a mobile phone on your bedside table, beside/in front of the SleepMinderTM).  In addition, wireless phone handsets (often called DECT phones) should be kept 4m (14ft) if they are operating on 5.8GHz frequency.       SleepMinderTM Unit Number    Service Expiry Date    Schedule
FCC WARNING STATEMENT  Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This  equipment  generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications.  However,  there  is  no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This  device  complies  with  FCC’s  RF  radiation  exposure  limits  set  forth  for  general  population.  It  must  be  installed  and operated to  provide a  separation distance of at least 20cm  from  all persons and must  not be co-located or operating in conjunction with any other antenna or transmitter.
BM04 SLEEPMINDERTM DEVICE INFORMATION System Description SleepMinderTM is a motion-recording system that uses a 5.8GHz motion sensor, logging to a Secure Digital memory card. It contains a real-time clock IC with internal battery and safe shutdown PP3 battery. It is intended for continuous operation during normal use. The SleepMinderTM System includes the following components: • 12V AC Adaptor (Friwo PP8 Medical 12V) • SleepMinderTM with SD memory card • SleepMinderTM carry case Warnings • Contains small parts that can be swallowed. Keep out of reach of children. • Read the instructions before using the SleepMinderTM unit. • Do not use in the presence of a flammable anesthetic mixture combined with air or with oxygen or nitrous oxide. • To avoid the risk of fire, do not use in the presence of flammable substances. • If the equipment is used in a manner not specified by BiancaMed, the performance and protection provided by the equipment may be impaired. • Only use with the power supply provided. • The batteries contained within this unit are for replacement by BiancaMed only. Cautions • Do not immerse or autoclave the SleepMinderTM Unit or AC/DC adapter. • Do not use outside the specified environmental conditions. • To avoid mechanical or electrical damage, do not drop the unit. • Do not use in the presence medical equipment such as magnetic resonance imaging (MRI) equipment. • Do not use in the presence of devices using radio frequencies (RF) such as cell phones, DECT phones, wireless LANs and broadband routers. Devices operating at 5.8GHz are to be kept at least 4 meters from SleepMinderTM. • Moving objects between SleepMinderTM and the subject may impair its performance. • Follow local laws and recycling plans regarding disposal or recycling of components, batteries and packaging. • Ensure the power cable does not pose a tripping or strangling risk. • The equipment needs to be installed in accordance with national wiring and installation regulations. • In the event of a power failure the performance of SleepMinderTM will be impaired. Statement of Electromagnetic Compliance This device meets the requirements of the Electromagnetic Compatibility (EMC), pursuant to the Collateral Standard, EN 60601-1-2, which addresses EMC in North America, Europe and other global communities. Explanation of symbols   DC power input only   Double Insulated Device  TUV approved   VDE approved  Device conforms to CE requirements  Refer to accompanying documents            Specifications Power supply:       Input: 100-240VAC 50-60Hz   Output: 12VDC 700mA Max. Current consumption:     200mA (12V input) Weight:         <500 grams Operating Conditions:     5 °C – 40 °C (20% - 95% Relative Humidity) Storage/Transport Conditions:   -20°C - 60°C (20% - 95% Relative Humidity) IP Rating:       None Battery Life (Clock & Backup):   5 years   © BiancaMed, NovaUCD, Belfield Innovation Park, Belfield, Dublin 4, Ireland.  Tel: +353 1716 3755. Fax: +353 1716 3709.  Email: help@biancamed.com     BM04.1DOC.003 Manual.  SleepMinderTM Unit Number    Service Expiry Date    Schedule

Navigation menu